Loading...
REVIEWED FIR2022-0136+Fire_Sprinkler_Equipment_Specification_Sheets+12.23.2022_1.02.08_PM+3284527FI R2022-0136 RECEIVEDRed Hawk Fire Protection, LLC Dec 28 2022 801 Valley Ave NW, Suite D CITY OF EDMONDS Puyallup, WA 98371 DEVELOPMENTSERVICES DEPARTMENTMENT (253) 840-9900 REDHAHF901 OP Ever VLOi.lp wt� MATERIAL SUBMITTAL FOR HOUSING HOPE EDMONDS LUTHERAN EDMONDS, WA RHFP JOB NO. 70106 TABLE OF CONTENTS Material Notes: WREDHAWK FIRE PROTECTION, LLC Any material with comment "Or Equal" indicates cut sheet represents an the exact or similar product to what we will install. These products generally are generic in nature and due to vender availability, price changes, or other unknowns, a similar product my be selected. All products used will meet all NFPA 13's, authority having jurisdiction, and projects specifications requirements. Description Make Model Comments CPVC Piping System Spears N/A Covers entire CPVC product line Black Steel Sprinkler Pipe - SCHD 7 (Flow) Bull Moose N/A Or Equal Black Steel Sprinkler Pipe - SCHD 10 & 40 Bull Moose N/A Or Equal Threaded Fittings - Ductile Iron Titus N/A Or Equal Grooved Rigid Coupling Victaulic Style 009N Grooved Flexible Coupling Victaulic Style 75 Grooved Reducing Coupling Victaulic Style 750 Grooved Flange Adaptor Victaulic Style 741 Grooved Fittings - 2" & Larger Victaulic N/A Firelock Description Make Model Comments CPVC - Double Offset Tolco/Eaton Fig. 29 1" and 1%" only CPVC - Stand -Off Hanger (No -Block) Anvil/ASC Fig. 188R Or Equal CPVC - Side Mount Hanger Anvil/ASC Fig. 187 Or Equal Loop/Ring Hanger - Standard Duty Caddy/nVent 115 Or Equal Rigid Strut Clamp Caddy/nVent RIGD Or Equal Riser Clamp Caddy/nVent 510 Or Equal Attachment - Universal Beam Clamp Caddy/nVent 300 Or Equal - • • & Restraints Description Make Model Comments Loop/Ring Hanger - Surge Restraint Afcon 310 Brace Structure Attachment - Generic (EQ Ear) Caddy/nVent CSBU Brace Pipe Attachment - Longitudinal and Lateral Brace Caddy/nVent CSB Universal Sway Brace Branch Line Restraint - Pipe Attachment Caddy/nVent CSBBRPO Branch Line Restraint - Structure Attachment - Wood & Concrete Caddy/nVent CSBBRS2EG Description Check Valve - Grooved Backflow - Grooved Double Check Detector FDC - Wall Mounted, 2-Way FDC - Wall Plate FDC - Breakaway Caps Test & Drain Valve, With Pressure Relief Description Air Pressure Gauge Water Flow Switch Alarm Bell - 24v, 10" Description Extended Coverage, Dry Sidewall Residential Pendent, Semi -Recessed Standard Spray, Pendent, Semi -Recessed Description Teflon Tape Pipe Dope Thread Oil CPVC Glue Fire Caulk for Fire Rated Penetrations Fire Rated Sleeves Sprinkler Spare Stock Box Make Model Victaulic Series 717 Backflow Direct/Ames Deringer 30 FPPI/ASC Fig 09-000 FPPI/ASC Varies FPPI/ASC Fig 09-503 Victaulic UTD Make Wika Instrument LP Potter Signal Potter Signal Make Reliable Reliable Reliable Model 111.10SP VSR PDC-10-24 Model DH56 (5.6K) F1res49 (4.9K) F1FR56 (5.6K) Make Model Argco PTFE Tape Industrial Argco Tuf-Glide FPPI/ASC Threadfit Clear Oil Spears FS-5 One Step Cement Hilti FS-One Hilti CP 680-P Argco 6510150 Comments Or Equal Finish to be Aluminum Or Equal Supplied with UM & UMC Risers Comments Or Equal Provided upon request Comments Ref. plans, color, temp, and response Ref. plans, color, temp, and response Ref. plans, color, temp, and response Comments Pipe & Fittings Submittal Information for Spears° Manufacturing Company pil I FlameGuard ° CPVC Fire Sprinkler System Date: Job Name: Engineer: Scope: This submittal covers the Spears® FlameGuard® CPVC Fire Sprinkler System suitable for residential and light hazard occupancies in accordance with The National Fire Protection Association (NFPA). The FlameGuard® System shall be sold as a complete system which consists of pipe, fittings and a specially formulated one-step primerless cement intended for use in wet, dry and pre -action systems in residential and light hazard Applications where the operating temperature/pressure does not exceed 175psi @ 150' F. (1.2 MPa @ 66' C) Product Specification: All CPVC fire sprinkler fittings and pipe shall be Spears® FlameGuard®. All solvent cement shall be Spears® FS-5 One -Step, and all thread sealant shall be Spears® Blue 75Tm as produced by Spears® Manufacturing Company. All Spears® FlameGuard® CPVC fire sprinkler fittings shall be manufactured in the U.S.A. from a Chlorinated Polyvinyl Chloride (CPVC) compound having a minimum cell classification of 23447 in accordance with ASTM D1784. Fittings shall be manufactured in strict compliance to ASTM F438 or F439, as applicable. All CPVC fire sprinkler piping shall be manufactured in the U.S.A. from a Chlorinated Polyvinyl Chloride (CPVC) compound having a minimum cell classification of 23447 in accordance with ASTM D1784. Piping shall be manufactured in strict compliance to ASTM F442. All CPVC solvent cement shall be a primerless, one-step type manufactured in strict compliance to ASTM F493 and approved for use with CPVC fire sprinkler systems. All CPVC fire sprinkler fittings, pipe and solvent cement shall be listed by Underwriters Laboratories (UL®), Underwriters Laboratories Canada (ULC®) and/or Factory Mutual Research Corporation (FM Global) and/or LPCB for use in residential and light hazard wet, dry and pre -action systems and bear their authorized certification marks. Thread sealant shall be approved by the fitting manufacturer for use with CPVC fire sprinkler products. All CPVC fittings, pipe, solvent cement and thread sealant shall be certified by NSF International as applicable. Pipe and solvent cement shall be certified to UL 2818 GREENGUARD GOLD. Product Marking: FlameGuard® system components shall be orange in color for identification and include required markings and approvals prescribed in ASTM F442 for pipe GSFG-0221 Location: Contractor: and ASTM F438 or F439 for fittings. Pipe and cement shall have GREENGUARD GOLD marking. Installation: Spears® FlameGuard® CPVC Fire Sprinkler System shall carry a working pressure of 175 psi @ 150F (1.2 MPa @ 660 C) and shall be installed in accordance with Spears® Manufacturing Company FlameGuard® CPVC Fire Sprinkler Products Installation Instructions (FG-3) and Addendums. National Fire Protection Association (NFPA) Standards 13, 13D, and 13R must be referenced for design and installation requirements in conjunction with the Installation Instructions and applicable local codes. Installation practices such as pipe support spacing, bracing, allowance for thermal expansion/contraction, solvent cementing and handling and storage shall be in accordance with the manufacturer's instructions and this specification. Buried pipe shall be in accordance with NFPA 24 for supply mains. The piping system shall be joined using a chemically resistant one-step primerless solvent cement joining process conforming to ASTM F493. The system shall be protected from ultra violet (UV) light exposure from the sun or other source and protected from any chemicals that are not compatible with the CPVC materials including but not limited to fire stopping materials, plasticizers, incompatible thread sealants, etc. NOTE: FlameGuard® CPVC piping systems can be leak tested using oil -free compressed air up to 25psi but must also be hydrostatically tested as required per NPFA standard. Referenced Standards: ASTM D1784 — Rigid Vinyl Compounds ASTM F438 — CPVC Schedule 40 Fittings ASTM F439 — CPVC Schedule 80 Fittings ASTM F442 — CPVC SDR Pipe ASTM F493 — Solvent Cements for CPVC Pipe & Fittings NFPA 13, 13D, 13R — National Fire Protection Association Standards NFPA 24 — Installation — Private Fire Service Mains NSF International Standard 14/61 — Potable Water Approvals: NSF° — NSF International Standard 14/61 — Potable Water Underwriters Laboratories — Listing Agency FM Global —Listing Agency UL-GREENGUARD GOLD Certified UL 2818 LPCB — Loss Prevention Council Board %v ,,,, BULL TVTOOSE® TUBE APPROVALS AND SPECIFICATIONS • ASTM A135, Grade A • ASTM A795, Type E, Grade A • Pressure rated to 300 psi • Underwriters Laboratories — United States of America • Underwriters Laboratories —Canada EDDY FLOW SPRINKLER PIPE SUBMITTAL DATA SHEET FINISHES AND COATINGS Eddy Flow Sprinkler Pipe receives an OD mill coating of water -based paint which has corrosion protection expected with a painted carbon steel product, i.e. it would be expected to resist corrosion for an extended and indefinite period in a clean and dry environment and, as environmental conditions deteriorate, the corrosion protection would also diminish. • Factory Mutual Eddy Flow Sprinkler Pipe (black) receives an ID mill coating of Eddy • NFPA-13 Guard II MIC preventative coating. EG2 has been tested at • NFPA-13R independent laboratories to resist bacterial growth and maintain • NFPA-14 minimal bacterial count after multiple flushes (25) of the pipe. • CIVIL DEFENSE APPROVAL — United Arab Emirates • Made in the United States of America • UL, ULC & FM listed for roll -groove, plain -end and welded joints for wet, dry, preaction and deluge sprinkler systems. • LEED v4 Certified • Eddy Flow Sprinkler Pipe when Hot Dip Galvanized by ASTM A123 and supplied by Bull Moose Tube is UL listed and FM approved. PRODUCT IDENTIFICATION • Every length of Bull Moose fire sprinkler pipe features large, easy -to - read, continuous stenciling, clearly identifying the manufacturer, type of pipe, size, and length. F11. O.D. (in) 1.660 1.900 2.375 2.875 3.500 4.500 I.D. (in) 1.530 1.728 2.203 2.705 3.334 4.310 Empty Weight (Ib/ft) 1.222 1.844 2.330 2.809 3.361 4.968 Water Filled Weight (lb/ft) 2.019 2.860 3.982 5.299 7.144 11.290 C.R.R.* 1.98 3.44 2.78 1.66 1.00 1.00 Pieces per Lift 61 61 37 30 19 19 *Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY SUBMITTAL INFORMATION Project Contractor Engineer Specification Reference Date System Type Locations Comments C Eddy Flow - Black Eddy Flow - Hot Dip Galvanized 1E3ULLTvT00SETUBE.00M UD C UDFM •nnnoveo BULL TVTOOSE® TUBE APPROVALS AND SPECIFICATIONS • ASTM A135, Grade A • ASTM A795, Type E, Grade A • Pressure rated to 300 psi • Underwriters Laboratories - United States of America • Underwriters Laboratories -Canada • Factory Mutual • NFPA-13 • NFPA-13R • NFPA-14 • CIVIL DEFENSE APPROVAL - United Arab Emirates • Made in the United States of America • UL, ULC & FM listed for roll -groove, plain -end and welded joints for wet, dry, preaction and deluge sprinkler systems. • LEED v4 Certified SCHEDULE 10 R 40 SPRINKLER PIPE SUBMITTAL DATA SHEET FINISHES AND COATINGS Schedule 10 & 40 Sprinkler Pipe receives an OD mill coating of water -based paint which has corrosion protection expected with a painted carbon steel product, i.e. it would be expected to resist corrosion for an extended and indefinite period in a clean and dry environment and, as environmental conditions deteriorate, the corrosion protection would also diminish. • Schedule 10 & 40 Sprinkler Pipe (black) receives an ID mill coating of Eddy Guard II MIC preventative coating. E62 has been tested at independent laboratories to resist bacterial growth and maintain minimal bacterial count after multiple flushes (25) of the pipe. • Schedule 10 & 40 Sprinkler Pipe when Hot Dip Galvanized by ASTM A123 and supplied by Bull Moose Tube is UL listed and FM approved. PRODUCT IDENTIFICATION • Every length of Bull Moose fire sprinkler pipe features large, easy -to - read, continuous stenciling, clearly identifying the manufacturer, type of pipe, size, and length. 0.0. (in) 1.315 1.660 1.900 2.375 2.815 3.500 4.500 6.625 8.625 I.D. (in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 6.357 8.249 Emptgweight (lb/ft) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 water Filled weight (lb/ft) 1.800 2.518 3.053 4.223 5.893 7.957 11.796 23.038 40.086 C.R.R.* 15.27 9.91 7.76 6.27 4.92 3.54 2.50 1.158 1.805 Pieces per Lift 91 61 61 37 30 19 19 10 7 0.0. (in) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 I.D. (in) 1.049 1.380 1.610 2.067 2.469 3.068 4.026 EmptyWeight (lb/ft) 1.680 2.270 2.720 3.660 5.800 7.580 10.800 Water Filled Weight (lb/ft) 2.055 2.918 3.602 5.114 7.875 10.783 16.316 C.R.R.* 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Pieces per Lift 70 51 44 30 30 19 19 *Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY **Not Eddy Guard II treated/Not produced by BMT SUBMITTAL INFORMATION C Project Contractor Engineer Specification Reference Date System Type Locations Comments OSchedule 10 - Black Schedule 10 - Hot Dip Galvanized O Schedule 40 - Black O Schedule 40 - Hot Dip Galvanized BULLNE00SETUBE.11COM ELBOW 90' SIZE (INCH) A(in) WEIGHT (LBS.) INNERBOX PCS/BOX MASTERCtn. PCS/Ctn. Remarks 1/2 1.12 0.25 50 200 UL, FM 1 1.50 0.57 20 60 UL, FM 11/4 1.75 0.97 20 40 UL, FM 11/2 1.94 1.43 15 30 UL, FM 2 2.21 1.93 8 16 UL, FM 21/2 2.70 2.89 12 12 UL, FM 90° REDUCING ELBOW SIZE (INCH) A (in) B (in) WEIGHT (LBS.) INNER BOX PCS/BOX MASTER Ctn. PCS/Ctn. Remarks 1 X 1/2 1.26 1.40 0.43 25 100 UL, FM 1 X 3/4 1.37 1.45 0.56 50 100 UL, FM 11/4 X 1/2 1.34 1.53 0.61 20 80 UL, FM 11/4 X 3/4 1.45 1.62 0.71 15 60 UL, FM 11/4 X 1 1.58 1.67 0.73 10 40 UL, FM 11/2 X 1/2 1.52 1.75 0.71 15 60 UL, FM 11/2 X 3/4 1.52 1.75 1.01 10 40 UL, FM 11/2 X 1 1.65 1.80 0.92 10 40 UL, FM 11/2 X 11/4 1.82 1.88 1.04 15 30 UL, FM 2 X 3/4 1.60 1.97 1.10 9 36 UL, FM 2 X 1 1.73 2.02 1.22 14 28 UL, FM 2 X 11/4 1.90 2.10 1.48 30 20 UL, FM 2 X 11/2 2.02 2.16 1.56 10 20 UL, FM ELBOW45° SIZE (INCH) q(inl WEIGHT (LBS.) INNERBO PCS/BOX MASTERCtn. PCS/Ctn. Remarks 1 1.12 0.55 20 60 UL, FM 11/4 1.29 0.85 20 40 UL, FM 11/2 1.43 1.12 10 30 UL, FM 2 1.68 1.14 12 24 UL, FM TEE SIZE (INCH) A (in) WEIGHT (LBS.) INNERBOX PCS/BOX MASTERCtn. PCS/Ctn. Remarks 1 1.50 0.83 20 40 UL, FM 11/4 1.75 1.30 14 28 UL, FM 11/2 1.94 1.68 12 24 UL, FM 2 2.25 2.79 8 16 UL, FM C&S <FM APPROVED DUCTILE IRON THREADED FITTINGS �-7eTITUS M1a MI `" 1 c Dus FM APPROVED COUPLING SIZE (INCH) A(in) WEIGHT (LBS.) INNERBOX PCs/BOX MASTERCtn. PCS/Ctn. Remarks 1 1.67 0.47 25 100 UL, FM 11/4 1.93 0.66 16 64 UL, FM 11/2 2.15 0.94 18 36 UL, FM 2 2.53 1.49 12 24 UL, FM REDUCING COUPLING SIZE (INCH) A(in) WEIGHT (LBS.) INNERBOX PCS/BOX MASTERCtn. PCS/Ctn. Remarks 3/4 x 1/2 1.44 0.26 60 180 UL, FM 1 x 1/2 1.69 0.37 30 120 Hexagon small end, UL, FM 1 x 3/4 1.69 0.42 25 ? 00 Hexagon small end, UL, FM 11/4 x 1/2 2.06 0.57 25 75 UL, FM 11/4x 3/4 2.06 0.60 25 75 UL, FM 11/4 x 1 2.06 0.62 15 60 UL, FM BUSHINGS SIZE (INCH) Alin) WEIGHT (LBS.) INNERBOX PCS/BOX MASTERCtn. PCS/Ctn. Remarks 3/4 x 1/2 1.02 0.14 75 300 outside head, UL, FM 1 x 1/2 1.14 0.28 50 200 outside head, UL, FM 1 x 3/4 1.14 0.19 50 200 outside head, UL, FM 11/4 x3/4 1.30 0.37 30 120 outside head, UL, FM 11/4 x 1 1.30 0.30 30 120 outside head, UL, FM 11/2 x 1 1.34 0.52 25 75 outside head, UL, FM 11/2 x 11/4 1.34 0.37 25 75 outside head, UL, FM 2 x 1/2 1.50 0.90 20 60 inside head, UL, FM 2 x 3/4 1.50 0.67 20 60 inside head, UL, FM 2 x 1 1.50 0.88 20 60 inside head, UL, FM 2 x 11/4 1.50 0.79 20 60 outside head, UL, FM 2 x 11/2 1.50 0.66 20 60 outside head, UL, FM PLUG SIZE (INCH) A (in) WEIGHT (LBS.) INNERBOX PCS/BOX MASTERCtn. PCS/Ctn. Remarks 1/2 0.95 0.10 50 600 hollow, UL, FM 3/4 1.07 0.16 35 420 hollow, UL, FM 1 1.25 0.26 20 240 hollow, UL, FM 11/4 1.36 0.31 40 120 hollow, UL, FM 11/2 1.42 0.51 30 90 hollow, UL, FM 2 1.57 0.65 20 60 hollow, UL, FM CROSS SIZE (INCH) Alin) WEIGHT (LBS.) INNERBOX PCS/BOX MASTERCtn. PCS/Ctn. Remarks 1 1.50 0.98 15 30 UL, FM 11/4 1.75 1.55 10 20 UL, FM 11/2 1.94 1.84 8 16 UL, FM 2 2.25 3.26 5 10 UL, FM CAP SIZE (INCH) A (in) WEIGHT (LBS.) INNERBOX PCS/BOX MASTERCtn. PCS/Ctn. Remarks 1 1.16 0.32 25 100 UL, FM 11/4 1.28 0.49 20 80 UL, FM 11/2 1.33 0.67 18 54 UL, FM 2 1.45 0.88 12 36 UL, FM c&us FM APPROVED Victaulic° Firel-ockT" Installation -Ready"' Rigid Couplings Aitaulic Style 009N and Style 109 10.64 Patented Patented 1.0 PRODUCT DESCRIPTION Available Sizes • Style 009N: 11/4 — 12"1 — DN300 • Style 109: 11/4 — 4"1 — DN100 Pipe Material • Schedule 10, Schedule 40 or specialty carbon steel pipe listed in Section 5. For use with alternative materials and wall thicknesses please contact Victaulic • For exceptions reference section 6.0 Notifications Maximum Working Pressure • Accommodates pressures ranging from full vacuum (29.9 in Hg/760 mm Hg) to 365 psi/2517 kPa Function • Joins carbon steel pipe with grooved ends conforming to publication 25.01 • Provides a rigid pipe joint designed to restrict axial or angular movement 2.0 CERTIFICATION/LISTINGS 0@11111 FM OLKB a VdS E L(SM Los 1219: Issue 3.1 EN 10311 Cert/LPCB Ref. 104-1a/36 Regulation (EU) No. 305/2011 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. victaulic.com 10.64 07072 Rev R Updated 1012021 © 2021 Victaulic Company. All rights reserved. 1 ictaulid victaulic.com 3.0 SPECIFICATIONS — MATERIAL ❑ Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade ❑ 65-45-15, is available upon special request. ❑ Housing Coating: (specify choice) ❑ Orange coating Red coating (standard for EMEA-I and Asia Pacific) ❑ Optional for Style 009N: Hot Dipped Galvanized per ASTM A123 Optional for Style 109: Mechanically Galvanized per ASTM B695 (available only in North America and Latin America). Gasket: (specify choice) Grade "E" EPDM (Type A) Vic-Plue" Pre -lubricated Gasket EPDM (Violet Color Code). Applicable for wet and dry (oil -free air) fire protection systems only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at-40°F/-40°C and above. Not compatible for use with hot water services or steam services. NOTES • Reference should always be made to publication 1-100, Victaulic Field Installation Handbook for gasket lubrication instructions. ❑ • Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to publication 05.01, Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: (specify choice) Standard: Carbon steel oval neck track bolt(s) meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (M10-M16) Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the ❑ mechanical property requirements of ASTM A563 Grade B (imperial) and ASTM A563M Class 9 (metric). Track bolts and hex nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type III (imperial) or Type II (metric). Optional for Style 009N: Stainless steel oval neck track bolts meeting the requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel Heavy Hex nuts meeting the requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling -resistant coating.' 1 Optional bolts/nuts are available in imperial size only. Coupling Linkage: High Strength Steel with comparable physical properties to that of the Track Bolt (ASTM A449). Linkage is zinc electroplated per ASTM B633 Fe/Zn 5, Type III Finish. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 2 ✓ctaulid victaulic.com 4.0 DIMENSIONS Style OO9N Two -Bolt Installation -Ready Coupling Size Maximum Maximum Allow. Bolt/Nut Dimensions Weight Actual Pre -assembled Joint Assembled Outside Working End Pipe End Approx. X Y X Y Nominal Diameter Pressure2 Load2 Separation3 Qty. Size Z (Each) inches inches psi lb inches inches inches inches inches inches inches Ib ON mm kPa N mm mm mm mm mm mm mm kg -MTa 1.660 365 790 0.10 2 3/8 x 2 3.13 5.00 2.75 5.00 2.00 1.4 DN32 42.4 2517 3514 2.54 M10 x 51 79 127 70 127 51 0.6 1 1/2 1.900 365 1035 0.10 3/8 x 2 3.38 5.13 3.00 5.13 2.00 1.5 DN40 48.3 2517 4604 2.54 2 M10 x 51 86 130 76 130 51 0.7 2 2.375 365 1617 0.12 2 3/a x 21/2 4.00 5.63 3.50 5.63 2.00 1.9 DN50 60.3 2517 7193 3.05 M10x63 102 143 89 143 51 0.9 21/2 2.875 365 2370 0.12 3/a x 21/2 4.50 6.13 4.00 6.13 2.00 2.1 73.0 2517 10542 3.05 2 M10 x 63 114 156 102 156 51 1.0 3.000 365 2580 0.12 3/8 x 21/2 4.63 6.00 4.13 6.13 2.00 2.1 DN65 76.1 2517 11476 3.05 2 M10 x 63 118 152 105 156 51 1.0 3 3.500 365 3512 0.12 2 3/8 x 21/2 5.13 6.75 4.63 6.75 2.00 2.3 DN80 88.9 2517 15622 3.05 M10 x 63 130 171 117 171 51 1.0 4 4.500 365 5805 0.17 3/a x 21/2 6.00 7.88 5.63 7.50 2.13 2.9 DN100 114.3 2517 25822 4.32 2 M10x63 152 200 143 191 54 1.3 4.250 365 5178 0.17 3/8 x 21/2 5.63 7.38 5.38 7.38 2.13 3.1 108.0 2517 23020 4.32 2 M 10 x 63 152 1.87 137 187 54 1.4 5 5.563 365 8872 0.17 2 1/2 x 3 7.25 9.25 6.75 9.13 2.25 5.0 141.3 2517 39456 4.32 M 12 x 76 184 235 171 232 57 2.3 5.250 365 7901 0.17 2 1/2 x 3 6.63 9.00 6.38 9.00 2.25 4.8 133.0 2517 35106 4.32 M 12 x 76 168 229 162 229 57 2.2 5.500 365 8672 0.17 2 1h x 3 6.88 9.25 6.75 9.13 2.25 4.9 DN125 139.7 2517 38529 4.32 M12x76 175 235 171 232 57 2.2 6 6.625 365 12582 0.17 1/2 x 31/4 8.38 10.38 7.88 10.13 2.25 6.0 DN150 168.3 2517 44469 4.32 2 M12x83 213 264 200 257 57 2.7 6.250 365 11198 0.17 1/2x 31/4 7.88 10.00 7.38 9.88 2.25 5.6 159.0 2517 49753 4.32 2 M 12 x 83 200 254 187 251 57 2.5 6.500 365 12112 0.17 1/2 x 31/4 8.00 10.25 7.75 10.13 2.25 6.0 165.1 2517 53813 4.32 2 M12 x 83 203 260 197 257 57 2.7 8 8.625 365 21326 0.17 '/a x 4 10.88 13.38 10.25 13.13 2.50 11.4 DN200 219.1 2517 94863 4.32 2 M16x101 276 340 260 333 64 5.2 8.500 365 20712 0.17 5/s x 4 10.63 13.25 10.25 10.13 2.63 11.4 216.0 2517 55968 4.32 2 M16x101 270 337 260 257 67 5.2 10 10.750 300 27229 0.25 7/8 x 61/2 13.75 17.00 13.25 17.13 2.75 22.6 DN250 273.0 2068 121121 6.4 2 M22 x 165 349 432 337 435 70 10.3 12 12.750 300 38303 0.25 7/a x 61/2 16.00 19.00 15.50 19.13 2.75 27.6 2 DN300 323.9 2068 170380 6.4 M22 x 165 406 483 394 486 70 12.5 2 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See the Listings/Approvals section of this publication for ratings on other pipe. 3 The allowable pipe separation dimension shown is for system layout purposes only. Style 009N couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. NOTES • When assembling Style 009N or Style 109 couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For Style 009N or Style 109 couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009N or Style 109 couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling. There is no interchanging of gaskets or housings between coupling styles. • Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009N or Style 109 couplings are supplied with Grade "E" Type A gaskets. These gaskets include an integral pipe stop, that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard Victaulic FlushSeal gaskets cannot be used with the Style 009N or Style 109 couplings. • The Allowable Pipe End Separation dimension shown is for system layout purposes only. Style 009N or Style 109 Installation -Ready rigid couplings are considered rigid connections and will not accommodate expansion/contraction or angular movement of the piping system. Contact Victaulic for torsional resistance information. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 3 ✓ctaulid victaulic.com 4.1 DIMENSIONS Style 109 One -Bolt Installation -Ready Coupling 74 YB YL co ' Style 0• 0• Joint Assembled Size Max. Max. Allow. Pipe Bolt/Nut Dimensions Weight Actual Pre -Assembled Assembled Outside Working End End Sep. Approx. YL YB X Z YL YB X Z Nominal Diameter Pressure Load Maximum Qty. Size (Each) inches inches psi Lbs. inches inches inches inches inches inches inches inches inches inches lb DN mm kPa N mm mm mm mm mm m m mm mm mm mm kg 1 1/4 1.660 365 790 0.10 3/8 x 21/4 1.97 2.49 3.17 1.95 1.93 2.59 2.84 1.95 1.5 1 DN32 42A 2517 1 3514 2.54 1 1 M10 x 57 50 63 81 50 49 66 72 50 0.7 1 1/2 1.900 365 1035 0.10 3/a x 2 Y4 2.13 2.60 3.41 1.95 2.1 2.68 3.07 1.95 1.6 1 DN40 48.3 2517 4603 2.54 M10 x 57 54 66 87 50 53 68 78 50 0.7 2 2.375 365 1617 0.12 3/a x 21/4 2.32 2.85 3.76 1.98 2.29 2.95 3.45 1.98 1.9 1 DN50 60.3 2517 7192 3.048 M10 x 57 59 72 1 96 1 50 58 1 75 88 1 50 0.9 21/2 2.875 365 2370 0.12 3/8 x 21/4 2.63 3.09 4.29 1.99 2.61 3.15 3.93 1.99 2.1 1 73.0 2517 10540 3.048 M10 x 57 67 78 109 51 66 80 100 51 1.0 3.000 365 2580 0.12 �/16 x 2 3/4 2.68 3.22 4.56 2.03 2.64 3.45 4.22 2.03 2.4 1 DN65 76.1 2517 11476 3.048 M71 x 69 68 82 116 52 67 88 107 52 1.1 3 3.500 365 3512 0.12 7/16 x 2 3/4 2.93 3.53 5.13 2.07 2.89 3.78 4.67 2.07 2.7 1 DN80 88.9 2517 15620 3.048 M11 x69 74 90 130 53 73 96 119 53 1.2 4 4.500 300 4771 0.17 �/16 X 2 3/4 3.47 4.01 6.03 2.08 3.43 4.22 5.56 2.08 3.5 1 DN100 114.3 2068 21223 4.318 M11 x69 88 102 153 53 87 107 141 53 1.6 4 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See the Listings/Approvals section of this publication for ratings on other pipe. 5 The allowable pipe separation dimension shown is for system layout purposes only. Style 109 couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. NOTES • When assembling Style 009N or Style 109 couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For Style 009N or Style 109 couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009N or Style 109 couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling. There is no interchanging of gaskets or housings between coupling styles. • Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009N or Style 109 couplings are supplied with Grade "E" Type A gaskets. These gaskets include an integral pipe stop, that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard Victaulic FlushSeal gaskets cannot be used with the Style 009N or Style 109 couplings. • The Allowable Pipe End Separation dimension shown is for system layout purposes only. Style 009N or Style 109 Installation -Ready rigid couplings are considered rigid connections and will not accommodate expansion/contraction or angular movement of the piping system. Contact Victaulic for torsional resistance information. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 4 ✓ctaulid victaulic.com 5.0 PERFORMANCE Style 009N Two -Bolt Installation -Ready Coupling Listings/Approvals6 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approval agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus FM VdS LPCB Actual Outside Nominal Diameter Sch.10 Sch.40 Sch.10 Sch.40 psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa DN mm bar bar bar bar bar bar 365 365 363 363 363 ir 363 11/4 1.660 DN32 42.4 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 365 365 363 363 363 363 11/2 1.900 DN40 48.3 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 365 365 363 363 363 363 2 2.375 DN50 60.3 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 365 365 363 363 — 363 21/2 2.875 2517 2517 2503 2503 — 2500 73.0 25 25 25 25 — 25 365' — 3638 — 363 363 DN65 2517' — 2503' — 2500 2500 7600 257 — 258 — 25 25 365 365 363 363 363 363 3 3.500 DN80 88.9 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 — 363 363 — — 4.250 — — 2503 2503 — - 108.0 - — 25 25 — — 365 365 363 363 363 363 4 4.500 DN100 114.3 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 _ _ e _ _ _ 5.2500 33. 133.0 2503' — — — — — 258 — — — 290' — 3638 — 232 363 DN125 500 20009 — 2503' — 1600 2500 139.7 39.7 20' — 258 — 16 25 290 365 363 363 232 363 5 5.563 2000 2517 2503 2503 1600 2500 141.3 20 25 25 25 16 25 s _ _ _ 59 159 _ _ 2503' — — — _ 258 —6.500 — — 29010 — 3638 — — 363 200010 — 2503' — — 2500 1651 2010 — 258 — — 25 6 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems -40° F/C and above. Please see the Victaulic Installation Manual 1-009N for details concerning when supplemental lubrication is required. 7 cULus listed for DIN 2458 (EN 10220) 2.6 mm pipe wall. 8 FM approved for BS 1387 (EN 10255) Medium 3.6 mm pipe wall. 9 cULus listed for EN 10220 4.0 mm pipe wall. 10 cULus listed for EN 10255 4.5 mm pipe wall. 11 With optional stainless steel fasteners, cULus Listed to 175psi/1207 kPa/12 bar and FM Approved to the FM ratings shown in the above table. The stainless steel fasteners have a marking designation of "316" on the end face of the bolt. 12 FM approved for 0.188" pipe wall. 13 cULus listed for 0.188" pipe wall. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 5 ✓ctaulid victaulic.com 5.0 PERFORMANCE (CONTINUED) Style 009N Two -Bolt Installation -Ready Coupling Listings/Approvals6 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approval agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus FIA VdS LPCB Actual Outside Nominal Diameter Sch.10 Sch.40 Sch.10 Sch.40 psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa DIN mm bar bar bar bar bar bar 300 365 300 363 232 363 6 6.625 2068 2517 2068 2503 1600 2500 DN150 168.3 20 25 20 25 16 25 290 — 363' — — — 8.515 2000 — 2503' — — — 216.3 20 — 25' — — — 300 365 30012 363 232 363 8 8 8.625 2068 2517 206812 2503 1600 2500 D 219.1 20 25 1 2012 25 1 16 1 25 30013 300 30012 300 — — 10 .7 10.750 206813 2068 206812 2068 — DN250 2 0 2013 20 2012 20 — 30013 300 25012 300 — — 12 12.750 .75 206813 2068 172012 2068 — — DN300 323 2013 20 1712 20 — — 6 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems -400 F/C and above. Please see the Victaulic Installation Manual 1-009N for details concerning when supplemental lubrication is required. 7 cULus listed for DIN 2458 (EN 10220) 2.6 mm pipe wall. 8 FM approved for BS 1387 (EN 10255) Medium 3.6 mm pipe wall. 9 cULus listed for EN 10220 4.0 mm pipe wall. 10 cULus listed for EN 10255 4.5 mm pipe wall. 11 With optional stainless steel fasteners, cULus Listed to 175psi/1207 kPa/12 bar and FM Approved to the FM ratings shown in the above table. The stainless steel fasteners have a marking designation of "316" on the end face of the bolt. 12 FM approved for 0.188" pipe wall. 13 cULus listed for 0.188" pipe wall. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 6 ✓ctaulid victaulic.com 5.1 PERFORMANCE Style 109 One -Bolt Installation -Ready Coupling Listings/ApprovalS15 The information provided below is based on the latest listing and approval data at the time of publication. Listings/ Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus FM VdS LPCB Actual Outside Sch.10 Sch.40 Sch.10 Sch.40 Nominal Diameter psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa DIN mm bar bar bar bar bar bar 365 365 365 365 232 363 11/4 1.660 2517 2517 2517 2517 1600 2503 DN32 42.4 25 25 25 25 16 25 365 365 365 365 232 363 11h 1.900 DN40 48.3 2517 2517 2517 2517 1600 2503 25 25 25 25 16 25 365 365 365 365 232 363 2 2.375 DN50 60.3 2517 2517 2517 2517 1600 2503 25 25 25 25 16 25 365 365 365 365 — — 21/2 2.875 2517 2517 2517 2517 — — 73.0 25 25 25 25 — — 365 365 365 365 232 363 3.000 2517 2517 2517 2517 1600 2503 DN65 76.1 25 25 25 25 16 25 365 365 365 365 232 363 3 3.500 DN80 88.9 2517 2517 2517 2517 1600 2503 25 25 25 25 16 25 300 365 300 300 — 290 4 4.500 DN100 114.3 2068 2517 2068 2068 — 2000 20 25 20 20 — 20 15 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems -40° F/C and above. Please see the Victaulic Installation Manual 1-109 for details concerning when supplemental lubrication is required. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 7 ✓ctaulid victaulic.com 5.2 PERFORMANCE Specialty Pipe Style 009N Two -Bolt Installation -Ready Coupling Listings/Approvals Size Pressure Rating cULus FM psi psi inches kPa kPa Pipe Type DN bar bar 1 1/4-4 300 EF DN32 — DN100 2068 N/A 20 300 300 EL 1 1/4-2 2068 2068 DN32 — DN50 20 20 300 ET40 1 1/4-2 2068 N/A DN32 — DN50 20 300 EZF 3-4 2068 N/A DN80 — DN100 20 300 300 EZT 1 1/4 — 2 2068 2068 DN32 — DN50 20 20 300 FF 11/2-4 2068 N/A DN40 — DN100 20 300 300 1 2 DN32 — DN50 2068 2068 IL 20 20 300 300 1 1/4-4 2068 2068 DN32— DN 100 20 20 MF 175 175 6 DN150 1205 1205 12 12 300 300 rMT 1 1/4 — 2 2068 2068 DN32 — DN50 20 20 300 MILT 1/4-2 N/A 2068 DN32 — DN50 DN32 20 300 TF 21/2-4 N/A 2068 73.0 mm — DN100 20 175 300 WG5, WG5E, WF5, WG7, WG7E, WL7 1 1/4-4 1205 2068 DN32 — DN100 12 20 300 300 WLS 1 1/4-2 2068 2068 DN32 — DN50 20 201& NOTES • EF = EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • EL = EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • ET40 = Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • EZF = EZ-Flow steel pipe manufactured by Northwest Pipe Co. • EZT = EZ-Thread steel pipe manufactured by Youngstown Tube Co. • FF = Fire -Flo steel pipe manufactured by Youngstown Tube Co. • GL = GL steel pipe manufactured by Wheatland Tube Co. • MF = Mega -Flow steel pipe manufactured by Wheatland Tube Co. • MT = Mega -Thread steel pipe manufactured by Wheatland Tube Co. • MILT = MILT steel pipe manufactured by Wheatland Tube Co • TF = Tex -Flow steel pipe manufactured by Tex -Tube Co. • WG5, WG5E, WF5 = WGalweld 5, WGalweld 5E, WFlow 5 steel pipe manufactured by Wuppermann Stahl GmbH. • WG7, WG7E, WL7 = WGalweld 7, Wgalweld 7E, WLight 7 steel pipe manufactured by Wuppermann Stahl GmbH • WLS = WLS steel pipe manufactured by Wheatland Tube Co. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com ✓ctaulid victaulic.com 5.3 PERFORMANCE Specialty Pipe Style 109 One -Bolt Installation -Ready Coupling Listings/Approvals Size Pressure Rating cULus FM inches psi psi kPa kPa Pipe Type DN bar bar 300 11/a 21/z N/A 2068 DN32 — 73.0 mm 20 300 EF 1 1/z — 21/z 20668 N/A DN40 — 73.0 mm 20 300 300 3-4 DN80 — DN100 2068 2068 --Ami 20 20 300 1 1/4 — 2 DN32 — DN50 N/A 2068 20 Easy -Flow 3-4 N/A 300 2068 DN80 — DN100 20 300 EL 11/4-2 N/A 2268 DN32 — DN50 300 300 ET40 11/4 — 2 2068 2068 DN32 — DN50 20 20 300 11/a 2 N/A 2068 DN32 — DN50 20 EZT 300 1 1/z — 2 2068 N/A DN40 — DN50 20 300 300 FF 11/2-4 20268 2068 DN40 — DN100 20 300 GL 11/4 — 2 N/A 2068 DN32— DN50 300 300 MF 11/4 — 4 20268 2068 DN32 — DN100 6M 20 300 300 11/4 — 2 MT DN32 — DN50 2068 2068 20 20 300 300 MLT 1 1/4 — 2 2068 2068 DN32 — DN50 20 20 NOTES • EF = EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • Easy -Flow = Easy -Flow steel pipe manufactured by Borusan Mannesmann Boru. • EL = EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • ET40 = Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • EZT = EZ-Thread steel pipe manufactured by Youngstown Tube Co. • FF = Fire -Flo steel pipe manufactured by Youngstown Tube Co. • GL = GL steel pipe manufactured by Wheatland Tube Co. • MF = Mega -Flow steel pipe manufactured by Wheatland Tube Co. • MT = Mega -Thread steel pipe manufactured by Wheatland Tube Co. • MLT = MLT steel pipe manufactured by Wheatland Tube Co. • TF = Tex -Flow steel pipe manufactured by Tex -Tube Co. • WG7, WG7E = WGalweld 7 and WGalweld 7E steel pipe manufactured by Wuppermann Stahl GmbH. • WLS = WLS steel pipe manufactured by Wheatland Tube Co. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 9 ✓ctaulid victaulic.com 5.3 PERFORMANCE (CONTINUED) Specialty Pipe Style 109 One -Bolt Installation -Ready Coupling Listings/Approvals Size Pressure Rating cULus FM inches psi psi kPa kPa Pipe Type DN bar bar 300 2 1/2 - 4 TF 73.00 mm - DN100 2068 20 300 1 1/4 - 2 N/A 2068 DN32 - DN50 20 WG7, WG7E 300 3-4 N/A 2068 DN80-DN100 20 300 WLS 1 '/4 - 2 N/A 7 2068 DN32 - DN50 � 1 20 NOTES • EF = EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • Easy -Flow = Easy -Flow steel pipe manufactured by Borusan Mannesmann Boru. • EL = EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • ET40 = Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • EZT = EZ-Thread steel pipe manufactured by Youngstown Tube Co. • FF = Fire -Flo steel pipe manufactured by Youngstown Tube Co. • GL = GL steel pipe manufactured by Wheatland Tube Co. • MF = Mega -Flow steel pipe manufactured by Wheatland Tube Co. • MT = Mega -Thread steel pipe manufactured by Wheatland Tube Co. • MLT = MLT steel pipe manufactured by Wheatland Tube Co. • TF = Tex -Flow steel pipe manufactured by Tex -Tube Co. • WG7, WG7E = WGalweld 7 and WGalweld 7E steel pipe manufactured by Wuppermann Stahl GmbH. • WLS = WLS steel pipe manufactured by Wheatland Tube Co. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 10 ✓ctaulid victaulic.com 6.0 NOTIFICATIONS A WARNING • Read and understand all instructions before attempting to install any Victaulic products. • Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. • These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. • It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. • The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. NOTICE • Victaulic does not recommend the use of any furnace butt -welded pipe with sizes 2'VDN50 and smaller Victaulic gasketed joint products. This includes, but is not limited to, ASTM A53 Type F pipe. 7.0 REFERENCE MATERIALS 05.01: Seal Selection Guide 25.01: Original Groove System (OGS) Groove Specifications 1-009N: Installation Instructions Fire Lock EZTm Rigid Coupling Style 009N 1-100: Victaulic Field Installation Handbook 1-109: Installation Instructions FireLockTM One -Bolt Rigid Coupling Style 109 I-ENDCAP: Victaulic End Caps Installation Instructions I -IMPACT: Impact Tool Usage Guidelines AN-001: Application Notification - Potential Incompatibility of Type F Pipe, Sizes NIPS 2" 1 DN50 and Smaller User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end -use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 11 ✓ctaulic® Victaulic° Flexible Coupling X'4taulic, Style 75 06.05 R3m6L tvaa7 � 1 — 87DN25 — DN200 Exaggerated for clarity 1.0 PRODUCT DESCRIPTION Available Sizes • 1 — 8"/DN25 — DN200 Pipe Material • Carbon steel • Stainless steel • For exceptions see section 6.0 Notifications Maximum Working Pressure • Accommodates pressures ranging from full vacuum (29.9 in Hg/760 mm Hg) up to 500 psi/3447 kPa/34 bar • Working pressure dependent on material, wall thickness and size of pipe Application • Joins standard roll grooved and cut grooved pipe, as well as grooved fittings, valves and accessories • Provides a flexible pipe joint which allows for expansion, contraction and deflection • Up to 50% lighter in weight than standard Victaulic Style 77 or Style 177N flexible couplings 2.0 CERTIFICATION/LISTINGS c @uS <FM> V LPCB LISTED NOTES • Download publication 10.01 for Fire Protection Certifications/Listings Reference Guide. • See publication 02.06: Victaulic Potable Water Approvals ANSI/NSF for potable water approvals if applicable. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Submitted By Date Spec Section Paragraph Approved Date victaulic.com 06.05 1470 Rev Q Updated 05/2020 © 2020 Victaulic Company. All rights reserved. 1 iictaulrc victaulic.com 3.0 SPECIFICATIONS — MATERIAL ❑ Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade ❑ 65-45-15, is available upon special request. ❑ Housing Coating: (specify choice) Standard: Orange enamel ❑ Optional: Hot dipped galvanized Optional: Contact Victaulic with your requirements for other coatings. Gasket: (specify choice') Grade "E" EPDM EPDM (Green stripe color code). Temperature range —30°F to +230°F/-34°C to +110°C. May be specified for hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many ❑ chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot +180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR USE WITH PETROLEUM SERVICES OR STEAM SERVICES. Grade "T" Nitrile Nitrile (Orange stripe color code). Temperature range —20OF to +180°F/-290C to +82°C. May be specified for ❑ petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; not compatible for hot dry air over +140°F/+60°C and water over +150°F/+66°C. NOT COMPATIBLE FOR USE WITH HOT WATER. Others For alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide - Elastomeric Seal Construction. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should ❑ always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: (specify choice2) Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (M10-M16) Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - Heavy Hex nuts) and ASTM A563M Class 9 (metric - ❑ hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FES, finish Type III (imperial) or Type II (metric). Optional (imperial): Stainless steel oval neck track bolts meeting the mechanical property requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel heavy nuts meeting the mechanical property requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling reducing coating. 2 Optional bolts/nuts are available in imperial sizes only. 06.05 1470 Rev Q Updated 05/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com ✓ct:auliic victaulic.com 4.0 DIMENSIONS Style 75 Flexible Coupling EMM. IF r I ►:� I� Pipe End Deflection from Size Separation3 Centerline3 Bolt/Nut Dimensions Weight Actual Outside Approx. Nominal Diameter Allowable Per Cplg. Pipe Qty. Size x Y Z (Each) inches inches inches inches/ft. imperial inches inches inches lb DIN mm mm Degrees mm/m metric mm mm mm kg 1 1.315 0-0.06 1 2-43' 0.57 2 ;% x 2 2.38 4.27 1.77 1.3 DN25 33.7 0-1.6 48 M10 x 51 61 108 45 0.6 1 1/4 1.660 0-0.06 2°-10 0.45 2 ;%x 2 2.68 4.61 1.77 1.4 DN32 42.4 0-1.6 38 M10 x 51 68 117 45 0.6 1 1/2 1.900 0-0.06 - 1056 0.40 2 4ix 2 2.91 4.82 1.77 1.5 DN40 48.3 0-1.6 33 M10 x 51 74 122 45 0.6 2 2.375 0-0.06 - 1031 0.32 2 %x2 3.43 5.22 1.88 1.7 DN50 60.3 0-1.6 26 M10 x 51 87 133 48 0.8 2 1/2 2.875 0-0.06 1 -15 0 0.26 2 ;%x 2 3.88 5.68 1.88 1.9 73.0 0-1.6 22 M 10 x 51 98 144 48 0.9 3.000 0-0.06 - 1012 0.26 2 % x 2 4.00 5.90 1.88 1.9 DN65 76.1 0-1.6 22 M10 x 51 102 150 48 0.9 3 3.500 0-0.06 1 o-2 0.22 1/2 x 2 3/4 4.50 7.00 1.88 2.9 DN80 88.9 0-1.6 18 M12 x 70 114 178 48 1.3 31/2 4.000 0-0.06 00 -54' 0.19 2 1/2 x 2 3/4 5.00 7.50 1.88 2.9 DN90 101.6 0-1.6 16 M12 x 70 127 191 48 1.3 4 4.500 0-0.13 10 36' 0.34 2 1/2 x 2 3/4 5.80 8.03 2.13 4.1 DN100 114.3 0-3.2 28 M12x70 147 204 54 1.9 4.250 0-0.13 1 °-41' 0.35 2 1/2 x 2 3/4 5.55 7.79 2.13 3.7 108.0 0-3.2 29 M 12 x 70 141 198 54 1.7 5.000 0-0.13 10 -26 0.25 2 ;%x 31/4 6.13 9.43 2.13 5.5 127.0 0-3.2 21 M16x83 156 240 54 2.5 5.250 0-0.13 0.28 # x 31/4 6.55 9.37 2.13 6.0 133.0 0-3.2 - 1021 24 2 M16x83 166 238 54 2.7 5.500 0-0.13 1u -18 0.28 2 %x31/4 6.80 9.59 2.13 6.3 DN125 139.7 0-3.2 24 M16x83 1 173 244 54 2.9 5 5.563 0-0.13 - 1018 0.27 2 % x 31/4 6.88 10.07 2.13 5.8 141.3 0-3.2 23 M 16 x 83 175 256 54 2.6 6.000 0-0.13 - 1012 0.21 2 % x 31/4 7.38 10.48 1.88 6.2 152.4 0-3.2 18 M 16 x 83 187 266 48 2.8 6.250 0-0.13 1-y 0.24 2 %x31/4 7.63 10.49 2.13 6.8 159.0 0-3.2 20 M16x83 194 266 54 3.1 6.500 0-0.13 1 0-7 0.23 21 %x31/4 7.84 10.66 2.08 6.6 165.1 0-3.2 58 M16x83 199 271 1 53 3.0 6 6.625 0-0.13 0 1 5 0.23 2 %x31/4 8.00 11.07 2.13 7.0 DN150 168.3 0-3.2 18 M16x83 203 281 54 3.2 0-0.13 - 0051 0.18 2 3/4 x 41/4 10.19 13.75 2.32 13.2 200A4 216.3 0-3.2 46 M20 x 108 259 350 59 6.0 8 8.625 0-0.13 00 -50' 0.18 2 3/4 x 41/4 10.34 13.97 2.13 12.4 DN200 219.1 0-3.2 14 M20 x 108 263 355 59 5.6 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 3/4-31IWIDN20-DN90; 25% for 4"/DN100 and larger. 4 Japanese Industrial Standard (JIS) size NOTE • Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. 06.05 1470 Rev Q Updated 05/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com ✓ctauhc victaulic.com 5.0 PERFORMANCE Style 75 Flexible Coupling Size Maximum Actual Outside Working Maximum Nominal Diameter Pressure' End Loads inches inches psi lb DIN mm kPa N 1 1.315 500 680 DN25 33.7 3447 3025 1.660 500 1080 1 Y4 DN32 42.4 3447 4805 1 '/2 1.900 500 1420 DN40 48.3 3447 6320 2 2.375 500 2215 DN50 60.3 3447 9860 21/2 2.875 500 3245 73.0 3447 14440 3.000 500 3535 DN65 76.1 3447 15730 3 3.500 500 4800 DN80 88.9 3447 21360 3'/2 4.000 500 6300 DN90 101.6 3447 28035 4 4.500 500 7950 DN 100 114.3 3447 35380 4.250 450 6380 108.0 3103 28395 5.000 450 8820 127.0 3103 39250 5.250 450 9735 133.0 3103 43325 5.500 450 10665 DN125 139.7 3103 47460 5 5.563 450 10935 141.3 3103 48660 6.000 450 12735 152.4 3103 56670 6.250 450 13800 159.0 3103 61405 6 6.625 450 15525 DN 150 168.3 3103 69085 6.500 450 14930 165.1 3103 66412 450 25625 200A4 216.3 1 3103 113986 8 8.625 450 26280 DN200 219.1 3103 116945 4 Japanese Industrial Standard (JIS) size ' Working Pressure and End Load are total, from all internal and external loads, based on ANSI B36.10 sized carbon steel pipe, grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. NOTE • WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11h times the figures shown. 06.05 1470 Rev Q Updated 05/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com 59 ✓ctauhc victaulic.com 6.0 NOTIFICATIONS A WARNING • Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. NO • Victaulic RX grooving rolls must be ordered separately RX on the front of the roll sets. 'ICE They are identified by a silver color and the designation NOTICE • Victaulic does not recommend the use of any furnace butt -welded pipe with sizes NPS 2'7DN50 and smaller Victaulic gasketed joint products. This includes, but is not limited to, ASTM A53 Type F pipe. 7.0 REFERENCE MATERIALS 02.06: Victaulic Potable Water Approvals ANSI/NSF 05.01: Victaulic Seal Selection Guide - Elastomeric Seal Construction 06.15: Victaulic Pressure Ratings and End Loads for Victaulic Couplings on Steel Pipe 10.01: Victaulic Products for Fire Protection Pipings Systems - Regulatory Approval Reference Guide 17.01: Victaulic Pipe Preparation for Use on Stainless Steel Pipe With Victaulic Products 17.09: Victaulic Ductile Iron Grooved Couplings Performance Data for Stainless Steel Pipe 25.01: Victaulic Standard Groove Specifications 26.01: Victaulic Design Data 29.01: Victaulic Terms and Conditions of Sale 1-100: Victaulic Field Installation Handbook I-ENDCAP: Victaulic End Cap Installation Safety Instructions User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end -use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 06.05 1470 Rev Q Updated 05/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com 5 ✓ctaulic Victaulic° Reducing Coupling XActaulic, Style 750 06.08 1.0 PRODUCT DESCRIPTION Available Sizes • 2 x 1" through 10 x 87DN50 x DN25 through DN250 x DN200 Pipe Material • Carbon steel • For exceptions reference section 6.0 Notifications NOTE • For other pipe materials, contact Victaulic. Maximum Working Pressure • 500 psi/3447 kPa • Working pressure dependent on material, wall thickness and size of pipe Application • Joins Original Groove System (OGS) roll grooved and cut grooved pipe, as well as OGS grooved fittings, valves and accessories • Permits direct reduction on piping run • Optional steel washer prevents telescoping of the smaller pipe inside the larger pipe during vertical system assembly Pipe Preparation • Cut or roll grooved in accordance with publication 25.01: Victaulic Standard Groove Specifications. 2.0 CERTIFICATION/LISTINGS c vL - <FM> SS LPCB ER[ uano NOTE • Download publication 10.01 for Fire Protection Certifications/Listings Reference Guide. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Submitted By Date Spec Section Paragraph Approved Date victaulic.com 06.08 1536 Rev M Updated 05/2020 © 2020 Victaulic Company. All rights reserved. 1 iictaulrc victaulic.com 3.0 SPECIFICATIONS — MATERIAL ❑ Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, ❑ Grade 65-45-15, is available upon special request. ❑ Housing Coating: (specify choice) Standard: Orange enamel. ❑ Optional: Hot dipped galvanized conforming to ASTM A153. Optional: Contact Victaulic with your requirements. Gasket: (specify choice') Grade "E" EPDM EPDM (Green stripe color code). Temperature range —30OF to +230°F/-340C to +110°C. May be specified for hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemical ❑ services. UL Classified in accordance with ANSI/NSF 61 for cold +730F/+230C and hot +180°F/+820C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR USE WITH PETROLEUM SERVICES OR STEAM SERVICES. Grade "T" Nitrile Nitrile (Orange stripe color code). Temperature range —20OF to +180°F/-290C to +82°C. May be specified for oil related services, including air with oil vapor, this gasket may be specified for temperatures rated up to +180°F/+82°C. For water related services, this gasket may be specified for temperatures rated up to +150°F/+66°C. For oil free, dry air services, this gasket may be specified for temperatures rated up to ❑ +140°F/+600C. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. Others For alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should Elalways be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts (specify choice2): Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (M10-M16) Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial — heavy hex nuts) and ASTM A563M Class ❑ 9 (metric — hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FES, finish Type III (imperial) or Type II (metric). Optional: Stainless steel oval neck track bolts meeting the mechanical property requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel heavy nuts meeting the mechanical property requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling reducing coating. Assembly Washer (optional): Galvanized carbon steel. 2 Optional bolts/nuts are available in imperial size only 06.08 1536 Rev M Updated 05/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com 4 ✓ctaulrc victaulic.com 4.0 DIMENSIONS Style 750 Reducing Coupling Pipe End Size Separation3 Deflect. From CL3 Bolt/Nut Dimensions Weight Actual Outside Approximate Nominal Diameter Allowable Per Cplg. Pipe Qty. Size X Y Z (Each) inches inches inches in/ft inches inches inches inches lb DN mm mm Degrees mm/m mm mm mm mm kg 2 x 1 DN50 DN25 2.375 1.315 x 60.3 33.7 0 - 0.07 0 - 1.8 0° - 57' 0.20 17 2 3/a x 2 3.38 85 5.28 134 1.88 48 2.7 1.2 0 - 0.07 0 - 1.8 0° 57 0.20 17 2 1/8 x 2 3.38 85 5.28 134 1.88 48 2.0 1.0 1 1/z DN40 1.900 48.3 2 1/z 2 x DN50 2.875 2.375 73.0 x 60.3 0 - 0.07 0 - 1.8 0° 47' 0.16 14 2 3/a x 2 4.00 102 5.93 151 1.88 48 3.1 1.4 2 DN65 x DN50 3.000 2.375 76.1 x 60.3 0 - 0.07 0 - 1.8 0° 47 0.16 14 2 1/z x 2'/a 4.38 111 6.63 168 1.88 48 4.6 2.1 3 2 DN80 x DN50 3.500 2.375 88.9 x 60.3 0 - 0.07 0 - 1.8 0° 39' 0.13 11 2 /z x 2 3/a 4.75 121 7.13 181 1.88 48 4.9 2.2 0 - 0.07 0 - 1.8 0° 39' 0.13 11 2 /z x 2 3/a 4.75 121 7.13 181 1.88 48 4.3 2.0 21/z 2.875 73.0 0 - 0.07 0-1.8 0° 39' 0.13 11 2 /z x 2'/a 4.75 121 7.13 181 1.88 48 4.2 1.9 DN65 3.00 76.1 4 2 414.500 DN100 x DN50 2.375 114.3 x 60.3 0-0.13 0-3.2 1° 19 0.28 25 2 5/a x 3'/a 6.25 159 8.90 226 2.25 57 8.1 3.7 0-0.13 0 - 3.2 1 ° 19' 0.28 25 2 5/a x 31/a 6.25 159 8.90 226 2.25 57 8.6 3.9 21/2 2.875 73.0 0-0.13 0 - 3.2 1 ° - 19' 0.28 25 2 5/a x 31/a 6.25 159 8.90 226 2.25 57 6.9 3.1 DN65 3.000 76.1 0-0.13 0 - 3.2 1 ° - 19' 0.28 25 2 5/a x 31/a 6.00 152 8.90 226 2.25 57 6.7 3.0 3 DN80 3.500 88.9 5 4 x DN 100 5.563 4.500 141.3 x 114.3 0-0.13 0 - 3.2 1 ° 3 0.22 19 2 3/4 x 4 /a 7.18 182 10.70 272 2.13 54 11.2 5.1 4 165.1 x DN 100 6.500 4.500 165.1 x 114.3 0-0.13 0 - 3.2 0° 55' 0.19 16 2 3/4 x 41/a 8.63 219 11.90 302 2.25 57 15.2 6.9 6 x 4 DN150 DN100 6.625 4.500 x 168.3 114.3 0-0.13 0-3.2 0° - 52' 0.18 15 2 3/4 x 41/a 8.63 219 11.90 302 2.25 57 16.7 7.6 0-0.13 0-3.2 0° 52' 0.18 15 2 3/a x 41/a 8.31 211 11.90 302 2.25 57 12.9 5.9 5 5.563 141.3 8 DN200 x 165.1 8.625 6.500 219.1 x 165.1 0-0.13 0 - 3.2 0° 38 0.13 11 2 7/8 x 5 10.75 273 14.88 378 2.50 64 23.2 10.5 0-0.13 0 - 3.2 0° 38 0.13 11 2 /a x 5 10.81 275 14.88 378 2.50 64 22.4 10.2 6 DN 150 6.625 168.3 10 8 DN250 x DN200 10.750 8.625 273.0 x 219.1 0-0.13 0 - 3.2 0° - 25' 0.90 8 2 1 x 51/2 13.12 333 17.26 438 2.62 67 31.4 14.2 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes, these figures should be reduced by: 50 % for 3/a - 3 1/z"/DN20 - DN90; and 25% for 4"/DN100 and larger. NOTE • Metric thread size bolts are available (color -coded gold) for all coupling sizes upon request. Contact Victaulic for details. 06.08 1536 Rev M Updated 05/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com 3 ✓ctauhc victaulic.com 5.0 PERFORMANCE Style 750 Reducing Coupling Size Maximum Working Maximum End Actual Outside Nominal Diameter Pressure4 Load4 inches inches psi lb DIN mm kPa N 2 1 2.375 1.315 350 500 DN50 x DN25 60.3 x 33.7 2413 2225 350 1000 11/2 1.900 DN40 48.3 2413 4450 21/2 2 2.875 2.375 500 2215 x DN50 73.0 x 60.3 3447 9850 2 3.000 2.375 350 1550 DN65 x DN50 76.1 x 60.3 2413 6900 3 2 3.500 2.375 350 1550 DN80 x DN50 88.9 x 60.3 2413 6900 500 3250 21/2 2.875 73.0 3447 14460 350 2475 3.00 DN65 76.1 2413 11010 4 2 4.500 2.375 350 1550 DN100 x DN50 114.3 x 60.3 2413 6900 350 2275 21/2 2.875 73.0 2413 10125 350 2475 3.000 DN65 76.1 2413 11014 500 4810 3 3.500 DN80 88.9 3447 21400 5 4 5.563 4.500 350 5565 x DN100 141.3 x 114.3 2413 24765 4 6.500 4.500 350 5565 165.1 x 114.3 165.1 x 114.3 2413 24765 6 4 6.625 4.500 350 5565 DN150 x DN100 168.3 x 114.3 2413 24765 350 8500 5 5.563 141.3 2413 37825 8 8.625 6.500 350 11610 DN200 x 165.1 219.1 x 165.1 2413 51645 350 12060 6 6.625 DN150 168.3 12413 53645 10 8 10.750 8.625 350 20450 DN250 x DN200 273.0 x 219.1 2413 90970 Working Presssure and End Load are total from all internal and external loads based on standard weight (ANSI) steel pipe standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe and material. Maximum working pressure rating based on larger pipe size. Maximum end load rating based on smaller pipe size. NOTES • WARNING: FOR ONE-TIME FIELD USE ONLY the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. • For joint pressure ratings on additional carbon steel wall thicknesses see publication 06.15. 06.08 1536 Rev M Updated 05/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com ✓ctauhc victaulic.com 5.1 PERFORMANCE Flow Data - Head Loss Equivalent lengths of standard weight steel pipe are shown in the tables. All data is based on water flowing at +60°F/+16°C. Flow Reducing Flow Expanding Equivalent Size Pipe Length Small Nominal Diameter inches ft DN m 2 5.9 DN50 x DN25 1.8 2.0 1 1/2 DN40 0.6 21/2 2 1.9 x DN50 0.6 2 1.9 DN65 x DN50 0.6 3 2 5.5 DN80 x DN50 1.7 3.8 21/2 1.2 3.8 DN65 1.2 4 2 6.0 DN100 x DN50 1.8 6.0 21/2 1.8 6.0 DN65 1.8 6.0 3 DN80 1.8 5 4 3.0 x DN100 0.9 4 6.0 165.1 x DN100 1.8 6 4 6.0 DN150 x DN100 1.8 4.5 5 1.4 8 0 7.3 DN200 x 165.1 2.2 7.3 6 DN150 2.2 10 8 8.7 DN250 x DN2001 2.7 Equivalent Size Pipe Length Small Nominal Diameter inches ft DN m 1 2 2.7 DN25 x DN50 0.8 1 1/2 2 1.9 DN40 x DN50 0.6 2 21/2 1.0 DN50 x 0.3 1.0 DN65 0.3 3.5 3 DN80 1.1 3.0 4 DN100 0.9 21/2 3 2.5 x DN80 0.8 3.0 4 DN100 0.9 3 2.5 DN65 x DN80 0.8 3.0 4 DN100 0.9 3 4 2.5 DN80 x DN100 0.8 4 5 3.3 DN100 x 1.0 4.6 165.1 1.4 4.6 6 DN150 1.4 5 6 2.3 x DN150 0.7 8 5.4 165.1 x DN200 1.7 6 8 6.0 DN150 x DN200 1.8 8 10 6.3 DN200 x DN250 1.9 06.08 1536 Rev M Updated 05/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com 5 ✓ctaulic victaulic.com 6.0 NOTIFICATIONS A WARNIN • Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or property damage. hL A WARNING • Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic pip- ing products. • Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Wear safety glasses, hardhat, and foot protection. • Only No. 61 bull plugs shall be used with Style 750 reducing couplings in systems where a vacuum may de- velop. Failure to follow these instructions could result in death or serious personal injury and property damage. NOTICE • Victaulic does not recommend the use of any furnace butt -welded pipe with sizes NIPS 2"/DN50 and smaller Victaulic gasketed joint products. This includes, but is not limited to, ASTM A53 Type F pipe. 7.0 REFERENCE MATERIALS 05.01: Victaulic Seal Selection Guide 06.15: Victaulic Pressure Ratings and End Loads for Victaulic Couplings on Steel Pipe 10.01: Victaulic Products for Fire Protection Piping Systems - Regulatory Approval Reference Guide 25.01: Victaulic Original Groove System (OGS) Groove Specifications 26.01: Victaulic Design Data 29.01: Victaulic Terms and Conditions of Sale 1-100: Victaulic Field Installation Handbook User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end -use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 06.08 1536 Rev M Updated 05/2020 © 2020 Victaulic Company. All rights reserved. victaulic.com m ✓ctaiulic VictaulicO Vic -Flange Adapters Licctsullicr Styles 741 and 743 06.06 t• %%;iio.� Style 741 Exaggerated for clarity Style 741 Exaggerated for clarity 2 - 12"/DN50 - DN300 14 - 24"/DN350 - DN600 Style 743 Exaggerated for clarity 2 - 12/DN50 - DN300 1.0 PRODUCT DESCRIPTION Available Sizes • Style 741: 2 — 24"/DN50 — DN600 • Style 743: 2 — 12"/DN50 — DN300 Pipe Material • Carbon steel • For use with stainless steel pipe, refer to Victaulic publication 17.09 for pressure ratings and end loads. • For use with PVC pipe, refer to Victaulic publication 32.01 for pressure ratings. • For use with aluminum pipe, refer to Victaulic publication 21.04 for pressure ratings and end loads. • For exceptions reference section 6.0 Notifications. Maximum Working Pressure • Style 741: Accommodates pressure ranging from full vacuum (29.9 in-Hg/760 mm-Hg) up to 300 psi/2068 kPa/21 bar • Style 743: Accommodates pressure ranging from full vacuum (29.9 in-Hg/760 mm-Hg) up to 720 psi/4964 kPa/50 bar Application • Designed to transition from flanged to grooved piping systems ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. victaulic.com 06.06 1534 Rev U Updated 05/2021 © 2021 Victaulic Company. All rights reserved. ictaUllicr 1 victaulic.com 2.0 CERTIFICATION/LISTINGS FM a LPCB, U� UDC VdS NOTE • See Victaulic publication 02.06: Victaulic Potable Water Approvals ANSI/NSF for potable water approvals if applicable. 3.0 SPECIFICATIONS — MATERIAL ❑ Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. ❑❑ Housing Coating: (specify choice) Standard: Black enamel. Optional: Hot dipped galvanized per ASTM A123. ❑ Optional: Contact Victaulic with your requirements for other coatings. Gasket: (specify choice') Victaulic Grade "E" EPDM EPDM (Green stripe color code). Temperature range —30OF to +230°F/-340C to +1100C. May be specified for hot El services. service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot +180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR USE WITH PETROLEUM SERVICES OR STEAM SERVICES. Victaulic Grade "T" Nitrile Nitrile (Orange stripe color code). Temperature range 20°F to +180°F/290C to +82°C. May be specified for oil related services, including air with oil vapor, this gasket may be specified for temperatures rated up to +180°F/+820C. For water related services, this gasket may be specified for temperatures rated up to +150°F/+660C. For oil free, dry air ❑ services, this gasket may be specified for temperatures rated up to +1400F1+600C. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. Others For alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Draw Bolts/Nuts (14 — 247DN350 — DN600 only): Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex flange nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - heavy hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex flange nuts are zinc electroplated per ASTM B633 FE/ZNS, finish Type III (imperial) or Type II (metric). 06.06 1534 Rev U Updated 05/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 4 ✓ctaulia' victaulic.com 4.0 DIMENSIONS Style 741 Vic -Flange Adapter 2 - 12"/DN5O - DN3OO ANSI Class 125 and 150 Flanges Exaggerated for clarity Size Assembly Bolt/Nut2 Sealing Surface Dimensions Weight Actual Outside "A" "B" Approximate Nominal Diameter Qty. Size Max. Min. W X Y z (Each) inches inches inches inches inches inches inches inches lb DN mm inches mm mm mm mm mm mm kg 2 2.375 2.38 3.41 6.75 6.00 4.75 0.75 3.1 DN50 60.3 4 /ss x 2 3/a 60 e 2.88 /8 x 3 87 172 152 121 19 1.4 2'/2 2.875 4 3.91 7.88 7.00 5.50 0.88 4.8 73.0 73 99 200 178 140 22 2.1 3 3.500 4 /s a x 3 3.50 4.53 8.50 7.50 6.00 1.00 5.3 DN80 88.9 89 115 216 191 152 1 25 2.4 4 4.500 8 a /a x 3 4.50 5.53 10.00 9.00 7.50 1.00 7.4 DN 100 114.3 114 141 1 254 229 191 25 3.4 5 5.563 5.56 6.71 11.00 10.00 8.50 1.00 8.6 8 s 1 /° x 3 /2 141.3 141 171 279 254 216 25 3.9 6 6.625 6.63 7.78 12.00 11.00 9.50 1.00 9.9 DN150 168.3 8 s /° x 3 1 /z 168 198 305 279 241 25 4.5 8 8.625 8.63 9.94 14.75 13.50 11.75 1.13 16.6 DN200 219.1 8 s /° x 3 1/z 219 252 375 343 298 29 7.5 10 10.750 12 , /s x 4 10.75 12.31 17.25 16.00 14.25 1.25 24.2 DN250 273.0 273 313 438 406 362 1 32 11.0 12 12.750 12 /e x 4 12.75 14.31 20.25 19.00 17.00 1.25 46.8 DN300 323.9 324 364 514 483 432 32 21.2 2 Total assembly bolts required to be supplied by installer. NOTE • IMPORTANT: Style 741 Vic -Flange adapters provide rigid joints when used on pipe with standard cut or roll groove dimensions and consequently allow no linear or angular movement at the joint. When used with Victaulic Series 700 butterfly valves, plastic pipe or light wall metallic pipe, small teeth in I.D. of key section should be removed and may be used on one side of the valve. Reference the 1-100: Victaulic Field Installation Handbook for details. Contact Victaulic for information on ISO 2084 (PN10); DIN 2532 (PN10) and JIS B-2210 (10K) flanges. 06.06 1534 Rev U Updated 05/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 3 ✓ctSUI_ic victaulic.com 4.1 DIMENSIONS Style 741 Vic -Flange Adapter DN50 - DN300/2 - 12" PN10 and PN16 Flanges FO` 14 1*100 Exaggerated for clarity Size PN10 Flanges PN16 Flanges Sealing Surface Dimensions Weight Assembly Assembly Actual Bolt/Nut2,3 Bolt/Nut2,3 Outside „A" "B" Approximate Nominal Diameter 0ty. Size 0ty. Size Max. Min. W X Y Z (Each) DIN mm mm mm mm mm mm mm kg inches inches mm mm inches inches inches inches inches inches lb DN50 60.3 4 M16 x 70 4 M16 x 70 60 87 178 165 127 22 1.4 2 2.375 2.38 3.41 7.00 6.50 5.00 0.88 3.1 DN65 76.1 76 103 210 187 146 22 2.1 4 M16 x 70 4 M16 x 70 3.000 3.00 4.05 8.25 7.38 5.75 0.88 4.7 DN80 88.9 89 115 219 200 162 22 2.4 8 M16 x 70 8 M16 x 70 3 3.500 3.50 4.53 8.63 7.88 6.38 0.88 5.4 DN100 114.3 114 141 251 229 181 25 3.5 8 M16x76 8 M76x76 4 4.500 4.50 5.55 9.88 9.00 7.13 1.00 7.7 DN125 139.7 141 171 276 251 213 29 4.2 8 M16 x 76 8 M16 x 76 5.500 5.55 6.73 10.88 9.88 8.38 1.13 1 9.3 159.0 8 M20 x 89 8 M20 x 89 159 187 314 289 241 29 4.5 6.250 6.25 7.36 12.38 11.38 9.50 1.13 10.0 165.1 165 192 305 279 241 25 5.0 6.500 8 3/4 x 3 1/2 8 3/4 x 3 �/2 6.50 7.56 12.00 11.00 1 9.50 1.00 11.0 DN 150 168.3 168 198 302 279 241 25 4.5 8 M20 x 89 8 M20 x 89 6 6.625 6.63 7.78 11.88 11.00 9.50 1.00 10.0 DN200 219.1 219 252 3684 3434 2954 294 7.5 8 M20 x 89 12 M20 x 89 8 8.625 8.63 9.94 14.50 13.50 11.63 1.13 16.6 DN250 273.0 273 313 4385 3975 3525 295 11.0 12 M20 x 89 12 M24 x 90 10 10.750 10.75 12.31 17.25 15.63 13.88 1.13 24.2 DN300 323.9 324 365 4796 4606 4006 326 17.4 12 M20 x 89 12 M24 x 90 1 12 12.750 12.75 14.31 18.88 18.13 15.75 1.25 38.4 2 Total assembly bolts required to be supplied by installer. 3 Longer bolts required when the Vic -Flange is utilized with wafer -type valves. 4 PN16 dimensions (mm/inches): W = 360/14.17; X = 340/13.38; Y = 295/11.63; Z = 32/1.25. 5 PN16 dimensions (mm/inches): W = 438/17.24; X = 406/16.00; Y = 356/14.00; Z = 32/1.25. 6 PN16 dimensions (mm/inches): W = 478/18.82; X = 445/17.50; Y = 410/16.13; Z = 32/1.25. NOTE • IMPORTANT: Style 741 Vic -Flange adapters provide rigid joints when used on pipe with standard cut or roll groove dimensions and consequently allow no linear or angular movement at the joint. When used with Victaulic Series 700 butterfly valves, plastic pipe or light wall metallic pipe, small teeth in I.D. of key section should be removed and may be used on one side of the valve. Reference the 1-100: Victaulic Field Installation Handbook for details. Contact Victaulic for information on ISO 2084 (PN10); DIN 2532 (PN10) and JIS B-2210 (10K) flanges. 06.06 1534 Rev U Updated 05/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com El ✓ctaiulic victaulic.com 4.2 DIMENSIONS Style 741 Vic -Flange Adapter DN50 - DN200/2 - 8" Australian Standard Table "E" Flanges Exaggerated for clarity Size Assembly Bolt/Nut2 Sealing Surface Dimensions Weight Actual Outside "A" "B" Approximate Nominal Diameter Qty. Size Max. Min. W X Y z (Each) DN mm mm mm mm mm mm mm kg inches inches inches inches inches inches inches inches inches Ib DN50 60.3 4 s 3 /a x 2 /° 60 84 165 152 114 19 1.9 2 2.375 2.38 3.31 6.50 6.00 4.50 0.75 4.1 DN80 88.9 4 s /s x 3 89 113 200 191 146 25 2.4 3 3.500 3.50 4.44 1 7.88 7.50 5.75 1 1.00 5.4 DN100 114.3 8 s /s x 3 114 131 251 229 178 25 3.3 4 4.500 4.50 5.16 9.88 9.00 7.00 1.00 7.2 DN150 168.3 8 1 3/' x 3 /z 168 192 286 279 235 25 4.5 6 6.625 6.63 7.56 11.25 11.00 9.25 1.00 9.9 DN200 219.1 219 247 368 343 292 29 5.7 8 8.625 8 3 /° x 3 /z 8.63 9.72 14.50 13.50 11.50 1.13 12.5 2 Total assembly bolts required to be supplied by installer. NOTE • IMPORTANT: Style 741 Vic -Flange adapters provide rigid joints when used on pipe with standard cut or roll groove dimensions and consequently allow no linear or angular movement at the joint. When used with Victaulic Series 700 butterfly valves, plastic pipe or light wall metallic pipe, small teeth in I.D. of key section should be removed and may be used on one side of the valve. Reference the 1-100: Victaulic Field Installation Handbook for details. Contact Victaulic for information on ISO 2084 (PN10); DIN 2532 (PN10) and JIS B-2210 (10K) flanges. 06.06 1534 Rev U Updated 05/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 5 ✓ctaiulia' victaulic.com 4.3 DIMENSIONS Style 741 Vic -Flange Adapter DN50 - DN200/2 - 8" Chinese Standard Table "E" Flanges Exaggerated for clarity Size Assembly Bolt/Nut2 Sealing Surface Dimensions Weight Actual Outside "A" "B" Approximate Nominal Diameter Qty. Size Max. Min. W X Y z (Each) DN mm mm mm mm mm mm mm kg inches inches mm inches inches inches inches inches inches Ib DN50 60.3 60 87 172 152 121 19 1.4 4 M76 X 70 2 2.375 2.38 3.41 6.75 6.00 4.75 0.75 3.1 DN65 76.1 78 94 210 187 146 22 2.1 4 M16 X 70 3.000 3.07 3.68 1 8.25 7.38 5.75 0.88 4.7 DN80 88.9 89 115 213 191 152.4 25 2.4 8 M16 X 76 3 3.500 3.50 4.53 8.38 7.50 6.00 1.00 5.4 108.0 110 126 248 222 181 25 3.5 8 M16 X 76 4.250 4.33 4.97 9.75 8.75 7.13 1.00 7.7 DN100 114.3 114 141 251 229 191 25 3.5 g M116 X 76 4 4.500 4.50 5.55 9.88 1 9.00 7.50 1.00 7.7 133.0 8 M 16 X 76 135 153 276 251 213 29 3.9 5.250 5.33 6.02 10.88 9.88 8.38 1.13 8.6 DN125 139.7 142 160 276 251 213 29 3.9 8 M76 X 76 5.500 5.59 6.28 10.88 9.88 8.38 1.13 8.6 159.0 159 187 314 289 241 29 4.5 8 M20 X 89 6.250 6.25 7.36 12.38 11.38 9.50 1.13 10.0 165.1 8 M20 X 89 165 195 305 280 241 29 4.5 6.500 6.50 7.68 1 12.00 11.00 9.50 1.13 1 10.0 DN200 219.1 219 252 368 343 298 29 7.5 12 M20 X 89 8 1 8.625 1 1 8.63 9.94 14.50 13.50 11.75 1.13 16.6 2 Total assembly bolts required to be supplied by installer. NOTE • IMPORTANT: Style 741 Vic -Flange adapters provide rigid joints when used on pipe with standard cut or roll groove dimensions and consequently allow no linear or angular movement at the joint. When used with Victaulic Series 700 butterfly valves, plastic pipe or light wall metallic pipe, small teeth in I.D. of key section should be removed and may be used on one side of the valve. Reference the 1-100: Victaulic Field Installation Handbook for details. Contact Victaulic for information on ISO 2084 (PN10); DIN 2532 (PN10) and JIS B-2210 (10K) flanges. 06.06 1534 Rev U Updated 05/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com m ✓ctSUI_ic victaulic.com 4.4 DIMENSIONS Style 741 Vic -Flange Adapter 14 - 24"/DN350 - DN600' ANSI Class 125 and 150 Flanges I paw" 00a, rmrla�."' 1,01,% Exaggerated for clarity Size Bolt/Nut Sealing Surface Dimensions Weight Actual Assembly2 DraW8 Outside "A" "B" Approximate Nominal Diameter Qty. Size Qty. Size Max. Min. T V W X Y Z (Each) inches inches inches inches inches inches inches inches inches inches lb DN mm inches inches mm mm mm mm mm mm mm mm kg 14 14.000 14.00 16.39 19.38 1.00 24.50 21.00 18.75 2.50 62.0 DN350 355.6 12 1 x 41/2 4 1/a x 31/2 356 416 492 25 622 533 476 64 28.1 16 16.000 16.00 18.39 21.50 1.00 27.13 23.50 21.25 2.50 79.0 DN400 406.4 16 1 x 41/2 4 1/a x 31/2 406 467 546 25 689 597 540 64 35.8 18 18.000 16 1 1/a x 4 3/a 4 3/a x 41/a 18.00 20.00 22.25 1.00 29.00 25.50 22.75 2.75 82.3 DN450 457.0 457 508 565 25 737 648 578 70 37.3 20 20.000 20 1 Ye x 5 1/4 4 3/4 x 41/a 20.00 22.50 25.00 1.00 31.50 27.50 25.00 2.75 103.3 DN500 508.0 508 572 635 25 800 699 635 70 46.9 24 24.000 T1 24.00 27.75 29.00 1.00 36.00 32.00 29.50 3.00 142.0 DN600 610.0 20 1/4 x 5 3/4 4 3/4 x 41/ 610 705 737 25 914 813 749 76 64.4 2 Total assembly bolts required to be supplied by installer. 7 For cut groove systems only. For 14 - 24"/DN350 - DN600 roll groove systems, AGS (Advanced Groove System) products are used. The Style 741 Vic -Flange adapter is not compatible with the AGS system. s Draw bolts supplied with 14 - 24"/DN350 - DN600 Vic -Flange adapters. NOTE • IMPORTANT: Style 741 Vic -Flange adapters provide rigid joints when used on pipe with standard cut or roll groove dimensions and consequently allow no linear or angular movement at the joint. When used with Victaulic Series 700 butterfly valves, plastic pipe or light wall metallic pipe, small teeth in I.D. of key section should be removed and may be used on one side of the valve. Reference the 1-100: Victaulic Field Installation Handbook for details. Contact Victaulic for information on ISO 2084 (PN10); DIN 2532 (PN10) and JIS B-2210 (10K) flanges. 06.06 1534 Rev U Updated 05/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 7 ✓ctSUI_ic victaulic.com 4.5 DIMENSIONS Style 743 Vic -Flange Adapter ANSI Class 250 and 300 Flanges ove to mate -j Z to flat -faced FlangeMating Fl % fig Proper Gasket Positioning Max. Min. Exaggerated for clarity Size Assembly Bolt/Nut2 Sealing Surface Dimensions Weight Actual Outside "A" "B" Approximate Nominal Diameter Qty. Size Max. Min. W X Y z (Each) inches inches inches inches inches inches inches inches lb DN mm inches mm mm mm mm mm mm kg 2 2.375 8 /a s 3 x 2.38 3.41 7.75 6.50 5.00 1.00 4.8 DN50 60.3 60 87 197 165 127 25 2.2 21/z 2.875 2.88 3.91 8.63 7.50 5.88 1.13 7.4 8 /a 3 3, x /a 73.0 73 99 219 191 149 29 3.4 3 3.500 8 x z /a a 3 /, 3.50 4.53 9.50 8.25 6.63 1.25 9.1 DN80 88.9 89 115 241 210 168 32 4.1 4 4.500 4.50 5.53 11.38 10.00 7.88 1.38 15.3 DN 100 114.3 8 a /a x 3 3 /a 114 141 289 254 200 35 6.9 5 5.563 5.56 6.72 12.38 11.00 9.25 1.50 17.7 141.3 8 3 /a x 4 141 171 1 314 279 235 38 1 8.0 6 6.625 6.63 7.78 13.88 12.50 10.63 1.50 23.4 DN150 168.3 12 s ,z /ax4/ 168 198 352 318 270 38 10.6 8 8.625 12 /a x 4 a /a 8.63 9.94 16.75 15.00 13.00 1.75 34.3 DN200 219.1 219 252 425 381 330 44 15.6 10 10.750 16 1 x5 , /a 10.75 12.31 19.25 17.50 15.25 2.00 48.3 DN250 273.0 273 313 489 445 387 51 21.9 12 12.750 12.75 14.31 22.25 20.50 17.75 2.13 70.5 DN300 323.9 16 , 3 1 /a x 5 /a 324 363 565 521 451 54 32.0 2 Total assembly bolts required to be supplied by installer. 06.06 1534 Rev U Updated 05/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com ✓ctSUI_ic victaulic.com 5.0 PERFORMANCE Style 741 Vic -Flange Adapter 2 — 12YDN50 — DN300 ANSI Class 125 and 150 Flanges Size Maximum Maximum Actual Nominal Outside Diameter Working Pressure9 End Load9 inches inches psi lb DN mm kPa N 2 2.375 300 1330 DN50 60.3 2068 5920 21/2 2.875 300 1950 73.0 2068 8680 3 3.500 300 2885 DN80 88.9 2068 12840 4 4.500 300 4770 DN 100 114.3 2068 21225 5 5.563 300 7290 141.3 2068 32440 6 6.625 300 10350 DN 150 168.3 2068 46060 8 8.625 300 17500 DN200 219.1 2068 77875 10 10.750 300 27215 DN250 273.0 2068 121110 12 12.750 300 38285 DN300 323.9 2068 170270 9 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. NOTE • WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. 06.06 1534 Rev U Updated 05/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 9 ✓ctaulia' victaulic.com 5.1 PERFORMANCE Style 741 Vic -Flange Adapter DN50 — DN300/2 — 12" PN10 and PN16 Flanges Size PN10 Flanges PN16 Flanges Actual Maximum Maximum Maximum Maximum Nominal Outside Diameter Working Pressure9 End Load9 Working Pressure9 End Load9 DIN mm bar N bar N inches inches psi lb psi lb DN50 60.3 10 2850 16 4561 2 2.375 145 640 230 1025 DN65 76.1 10 4540 16 7275 3.000 145 1020 230 1635 DN80 88.9 10 6210 16 9925 3 3.500 145 1395 230 2230 DN 100 114.3 10 10260 16 16420 4 4.500 145 2305 230 3690 DN125 139.7 10 15330 16 24520 5.500 145 3446 230 5512 159.0 10 19800 16 31400 6.250 145 4450 230 7056 DN150 168.3 10 22250 16 35600 6 6.625 145 5000 230 8000 DN200 219.1 10 37690 16 60320 8 8.625 145 8470 230 13555 DN250 273.0 10 58560 16 93695 10 10.750 145 13160 230 21055 DN300 323.9 10 82370 16 131810 12 12.750 145 18510 230 29620 9 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. NOTE • WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1'h times the figures shown. 06.06 1534 Rev U Updated 05/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 10 ✓ctaulia' victaulic.com 5.2 PERFORMANCE Style 741 Vic -Flange Adapter DN5O — DN2OO/2 — 8" Australian Standard Table "E" Flanges Size Maximum Maximum Actual Outside Working End Nominal Diameter Pressure9 Load9 ON mm kPa N inches inches psi lb 010 60.3 1400 3996 2.375 203 900 80 88.9 1400 8700 3.500 203 1955 00 :DN200 114.3 1400 14374 4.500 203 3220 50 168.3 1400 31150 6.625 203 7000 219.1 1400 52777 8.625 203 11860 9 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. NOTE • WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1'h times the figures shown. 5.3 PERFORMANCE Style 741 Vic -Flange Adapter DN5O — DN2OO/2 — 8" Chinese Standard Table 'E" Flanges Size Actual Maximum Maximum Outside Working End Nominal Diameter Pressure9 Load' DN mm kPa N inches inches psi lb DN50 60.3 1400 3996 2 2.375 203 900 DN65 76.1 1400 6365 3.000 203 1431 DN80 88.9 1400 8700 3 3.500 203 1955 108.0 1400 12819 4.250 203 2882 DN 100 114.3 1400 14374 4 4.500 203 4370 133.0 1400 19440 5.250 203 4822 DN125 139.7 1400 21448 5.500 203 4822 159.0 1400 27784 6.250 1 203 6246 165.1 1400 29920 6.500 203 67" DN200 219.1 1400 52777 8 8.625 203 11860 9 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. NOTE • WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1V2 times the figures shown. 06.06 1534 Rev U Updated 05/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 11 ✓ctaiulicr victaulic.com 5.4 PERFORMANCE Style 741 Vic -Flange Adapter 14 — 24"/DN350 — DN600 ANSI Class 125 and 150 Flanges Size Maximum Working Maximum End Actual Outside Nominal Diameter Pressure9 Load9 inches inches psi lb DIN mm kPa N 14 14.000 300 46180 DN350 355.6 2068 205500 16 16.000 300 60300 DN400 406.4 2068 268335 18 18.000 300 76340 DN450 457.0 2068 339700 20 20.000 300 94250 DN500 1 508.0 1 2068 419400 24 24.000 300 135700 DN600 1 610.0 2068 603865 9 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. NOTE • WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11h times the figures shown. 5.5 PERFORMANCE Style 743 Vic -Flange Adapter ANSI Class 250 and 300 Flanges Size Maximum Working MaximumEnd Actual Outside Nominal Diameter Pressure9 Load9 inches inches psi lb DN mm kPa N 2 2.375 720 3190 DN50 60.3 4964 14200 21/2 2.875 720 4670 73.0 4964 20780 3 3.500 720 6925 DN80 88.9 4964 30815 4 4.500 720 11445 DN 100 114.3 4964 50930 5 5.563 720 17500 141.3 4964 77875 6 6.625 720 24805 DN150 168.3 4964 110380 8 8.625 720 42045 DN200 219.1 4964 187100 10 10.750 720 65315 DN250 273.0 4964 290650 12 12.750 720 91880 DN300 323.9 4964 408870 JL 9 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. NOTE • WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1'h times the figures shown. 06.06 1534 Rev U Updated 05/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 12 ✓ctaiulia' victaulic.com 6.0 NOTIFICATIONS • The Style 741 (2 — 12"/DN50 — DN300) design incorporates small teeth inside the key shoulder I.D. to prevent rotation. These teeth should be removed when Vic -Flange adapter is utilized with a Victaulic Series 700 grooved - end butterfly valve, Schedule 5 pipe or plastic pipe. Vic -Flange adapter Style 741 may only be used on one side of Victaulic Series 700 butterfly valve, sizes 2 — 47DN50 — DN100 fitted with standard or latch -lock handles. • Vic -Flange adapter must be assembled so it does not interfere with handle operation. Because of the outside flange dimension, Vic -Flange adapter should not be used within 90' of one another on a standard fitting. When wafer or lug -type valves are used adjoining a Victaulic fitting, check disc dimensions to assure proper clearance. • Vic -Flange adapters should not be used as anchor points for tie -rods across nonrestrained joints. Mating rubber faced flanges, valves, etc. requires the use of a Vic -Flange washer. • Area A-B noted in the drawings in sections 4.0 through 4.5 must be free from gouges, undulations or deformities of any type for effective sealing. • Vic -Flange adapter gaskets must always be assembled with the color coded lip on the pipe and the other lip facing the mating flange. • Vic -Flange hinge points must be oriented approximately 90'to each other when mated. • Flange Washers: Vic -Flange adapters require a smooth hard surface at the mating flange face for effective sealing. Some applications for which the Vic -Flange adapter is otherwise well suited do not provide an adequate mating surface. In such cases, it is recommended that a metal (Type F phenolic for Style 641 with copper systems) Flange Washer be inserted between the Vic -Flange adapter and the mating flange to provide the necessary sealing surface. • Typical applications where a Flange Washer should be used are: A. When mating to a serrated flange: a flange gasket should be used adjacent to the serrated flange and then the Flange Washer is inserted between the Vic -Flange adapter and the flange gasket. B. When mating to a wafer valve: where typical valves are rubber lined and partially rubber faced (smooth or not), the Flange Washer is placed between the valve and the Vic -Flange adapter. C. When mating a rubber faced flange: the Flange Washer is placed between the Vic -flanges and the rubber faced flange. D. When mating AWWA cast flanges to IPS flanges: the Flange Washer or Transition Ring is placed between two Vic -Flange adapters with the hinge points oriented 900 to each other. If one flange is not a Vic -Flange adapter (e.g., flanged valve), then a flange gasket must be placed adjacent to that flange and the Flange Washer inserted between the flange gasket and the Vic -Flange adapter. Transition rings rather than Flange Washers must be used when mating Style 741 to Style 341 Flange Adapters in sizes 14 — 24"/DN350 — DN600. E. When mating to components (valves, strainers, etc.) where the component flange face has an insert: follow the same arrangement as in Application 1. F. Additional information regarding the use of a Flange Washer can be found in the 1-100: Victaulic Field Installation Handbook. • When ordering Flange Washers, always specify product style (Style 741 or Style 743) and size to assure proper Flange Washer is supplied. NOTE • Style 741 is compatible with ANSI CL 125 or CL150, PN10/16 and Australian Standard Table E bolt hole patterns. 06.06 1534 Rev U Updated 05/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 13 ✓ctaiulicr victaulic.com 6.0 NOTIFICATIONS (Continued) WARNING • Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or property damage. NOTICE • Victaulic RX grooving rolls must be ordered separately. They are identified by a silver color and the designation RX on the front of the roll sets. NOTICE • Victaulic does not recommend the use of any furnace butt -welded pipe with sizes NPS 2'7DN50 and smaller Vic- taulic gasketed joint products. This includes, but is not limited to, ASTM A53 Type F pipe. 7.0 REFERENCE MATERIALS 02.06: Victaulic Potable Water Approvals 05.01: Victaulic Seal Selection Guide 10.01: Victaulic Regulatory Approval Reference Guide 17.01: Victaulic Pipe Preparation for Use on Stainless Steel Pipe With Victaulic Products 17.09: Victaulic Pressure Ratings and End Loads for Victaulic Ductile Iron Grooved Couplings on Stainless Steel 29.01: Victaulic Terms and Conditions/Warranty 1-100: Victaulic Field Installation Handbook User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end -use application, in accordance with industry standards and project specifications, as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 06.06 1534 Rev U Updated 05/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 14 x A _C_ t -SU I _ic r Victaulic° FireLock"' Fittings 1.0 PRODUCT DESCRIPTION Available Sizes • 11/4 — 8"/DN32 — DN200 ✓ctaulEc 10.03 Maximum Working Pressure • Pressure ratings for Victaulic FireLockTm Fittings conform to the ratings of Victaulic Fire Lock EZTM Style 009N couplings (refer to publication 10.64 for more information). Application • FireLockTM fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. • Connects pipe, provides change in direction and adapts sizes or components Pipe Materials • Carbon steel 2.0 CERTIFICATION/LISTINGS c&us <S> (LPBa VdS C E LISTED EN 10311 Regulation (EU) No. 305/2011 3.0 SPECIFICATIONS - MATERIAL Fitting: Ductile iron conforming to ASTM A536, Grade 65-45-12. Fitting Coating: (specify choice) ❑ Orange coating. ❑ Red coating (standard for EMEA-1 and Asia Pacific). ❑ Optional: Hot dipped galvanized. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. victaulic.com 10.03 01539 Rev 0 Updated 10/2021 © 2021 Victaulic Company. All rights reserved. 1 ActaulEcc victaulic.com 4.0 DIMENSIONS �CtoE+toE� u ctoE o 0 ®o o0 0-o I FT toE IO Jv�I� tE e No. 001 No. 003 No. 002 No. 006 No. 001 No. 003 No. 002 No. 006 90° Elbow 45° Elbow Straight Tee Cap Actual Approximate Approximate Approximate Approximate Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each T Each inches inches inches lb inches lb inches Ito inches lb DN mm mm kg mm kg mm kg mm kg 11/4 1.660 - - - - - - 0.82 0.3 DN32 42.4 - - - - - - 21 0.1 11/2 1.900 0.82 0.4 DN40 48.3 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 DN50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 2.25 2.4 3.00 3.8 DN65 76.1 76 1.5 57 1.1 76 1.7 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 DN80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 DN100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 141.3 124 5.7 83 3.8 124 7.1 25 1.9 5.500 4.88 12.4 3.25 8.2 4.88 15.4 DN125 139.7 124 5.6 82.6 3.7 124 6.9 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 DN150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 140 7.9 89 5.2 140 9.9 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 DN200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 8.515 6.81 23.1 - - 6.94 33.6 - - 216.3 173 10.5 - - 176 15.2 - - 10.03 01539 Rev 0 Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 2 ✓ctaulil victaulic.com 5.0 PERFORMANCE Flow Data Size Frictional Resistance Equivalent of Straight Pipe' No. 002 Actual Elbows Straight Tee No.001 No.003 Nominal Outside Size Diameter 90' Elbow 45' Elbow Branch Run inches inches feet feet feet feet DN mm meters meters meters meters 1 1/4 1.660 - - - - DN32 42.4 - - - - 11/2 1.900 - - - - DN40 48.3 - - - - 2 2.375 3.5 1.8 8.5 3.5 DN50 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 73.0 1.3 0.7 3.3 1.3 3.000 4.5 2.3 11.0 4.5 DN65 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 DN80 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 DN 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 141.3 2.6 1.3 6.4 2.6 5.500 8.3 4.1 20.6 8.3 DN 125 139.7 2.5 1.3 6.3 2.5 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 DN 150 168.3 3.0 1.5 7.6 3.0 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 DN200 219.1 4.0 1.5 10.1 4.0 8.515 13.0 - 33.0 13.0 216.3 4.0 - 10.1 4.0 1 The flow data listed is based upon the pressure drop of Schedule 40 pipe. 10.03 01539 Rev 0 Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com ✓ctaulic° victaulic.com 6.0 NOTIFICATIONS General Notes NOTE: When assembling FireLock EZT" couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZT°" Style 009N/009H couplings, use FireLock" No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H/009N couplings. 7.0 REFERENCE MATERIALS 10.64: Victaulicg FireLockT"l Rigid Coupling Style 009N 10.02: Victaulic@ FireLockT^^ Rigid Coupling Style 005H with Vic-PlusTm Gasket System 29.01: Victaulic@ Terms and Conditions of Sale User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products for a particular end -use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations. instructions. Nothing in this or any other document, nor any verbal recommendation, Installation advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale, installation instructions of the product you are installing. Handbooks are included with each shipment guide, or this disclaimer. of Victaulic products, providing complete installation and assembly data, and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such Trademarks material, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right. The terms "Patented" or "Patent Pending' refer to design or utility patents Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 10.03 01539 Rev 0 Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com ✓ctaulic° 4 Hangers & Attachments Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe & IPS Steel Pipe** Size Range: Available in 3/4" (2omm) and 1 " (25mm) pipe sizes Material: Pre -Galvanized Steel Function: Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 11/2" (20mm) x 11/2" (20mm) from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. Features: • Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. • Offset edge eliminates abrasion. • Attaches easily to wood structure with two special #10 x 1" hex head self -threading screws furnished with product. • Can be used as a single offset hanger by aligning "dimples" with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish: Pre -Galvanized Order By: Figure number and pipe size. Patent Pending ** With reduced spacing, consult factory. Double Offset Single Offset 9 0 0 O 11m (38.1 mm) ®TOLCO c&uS LISTED 1 1.5" (38.1 mm) }-----------, 1---= .5° (38.1 mm) Install using a rechargeable electric drill fitted with a 5/16" (7.9mm) socket attachment with the special hex head self -tapping screws provided. Install screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of the screws to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger / restrainer function. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line CPVC Z ANVIL ..T....I.-I Fig.188R (Formerly Afcon Fig. 514) Size Range: 'A" through 2" Material: Carbon Steel Finish: Pre -Galvanized per ASTM A653 Service: Two Hole Standoff Hanger & Restrainer • Hanger and surge restraint for horizontal CPVC, steel, and copper piping when installed on the top, bottom, and side of the supporting structure. • Guide for vertical CPVC, steel, and copper piping when installed on the side of the supporting structure. • Horizontal and vertical seismic restraint per NFPA 13-2016 requirements. • May be installed with concrete, steel structural members, and other structural members with fasteners which comply with the requirements of NFPA 13. Approvals: cULus Listed Patents: No. 6,648,278 Installation: • Snap hanger over pipe. If needed, squeeze strap back around pipe. • CPVC pipe must be allowed to slide freely through the Fig.188R. • Secure hanger to mounting surface with screws provided or with listed fasteners. Features: • Beveled edge design helps protect the CPVC pipe from any rough surface and eliminates pipe abrasion. • Easily attaches to wood structure with #10 x 1" hex washer head self -threading screw supplied with product. No pre -drilling required. • Bottom of pipe is offset 11/2" from the structure. Eliminates wooden spacer blocks. Ordering: Specify CPVC pipe size, figure number and description. Hanger & Restrainer Hange Restra D& 'ainer Installation - Backing Nut Hanger =1 - at top fastener Restraint = 2 - on each fastener Per NFPA-13D and NFPA-13R PROJECT INFORMATION Project: APPROVAL []Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-07.20 CPVC Z ANVIL ..T....I.—I F1g.188R (Formerly Afcon Fig. 514) TWo Hole Standoff Hanger & Restrainer (cons.) a p 4..p a d. . p d dp dp. d Q p. d u Hanger and Restrainer B = A E -(D- + OC � \ , (r::: L / FIG.188R: DIMENSIONS (IN) • WEIGHT (LBS) CPVC Pipe Size A B 0C D E F G Max. Hanger Spacing (FT.) Approx. Weight/100 (Ibs) 3/4 23/4 31/2 1/4 2 1 2% 11/2 51/2 11 1 21'/16 31/2 1/4 2'/16 1 2"/16 11/2 6 12 11/4 213/ 6 31/2 1/4 25/ 6 1 31/4 11/2 61/2 13 11/2 3% 41/4 1/4 27/6 1 31/2 11/2 7 14 2 311/16 4% 1/4 211/16 1 4 11/2 8 16 FIG.188R: LISTED FASTENERS Pipe Wood and Composite Beams Steel (18ga. Minimum) CPVC Screw Supplied or #10 x 1 " TEK Screw #14 x 1 " TEK Screw or 1/4" x 1 " TEK Screw Steel & Copper #14 x 1 " TEK Screw or 1/4" x 11/2" Lag Screw #14 x 1 " TEK Screw or 1/4" x 1 " TEK Screw PH-07.20 CPVC Z ANVIL Fig. 187 (Formerly Afton Fig. 511) TWo Hole 90° Side Mount Strap Size Range: 3/4" through 2" Finish: Zinc Plated Steel (Hot -Dip Galvanized optional) Service: Hanger for CPVC pipe in the horizontal position on the bottom of structural wood 7 beams and Steel 20 Ga. (min.) (Fig. A). Can be used as a restrainer, only in Stee120 Ga. (min) (Fig. 8). During installation, adjust hanger mounting flanges such that pipe contacts both mounting surface and hanger, minimizing vertical pipe movement. Approvals: UL and ULC Listed. Installation: i • Snap hanger over pipe. • Secure hanger to mounting surface with screws provided. y • Do not anchor tightly to mounting surface. Pipe must be allowed to move freely through hanger. • Steel applications require two (2) #14 x 1" hex washer head self -drilling TEK screws. Not Supplied. Part Number STD-0090. c UL us Features: LISTED • Beveled edge design helps protect the CPVC pipe from any rough surface. • Easily attaches to wood structure with #10 x 1" hex washer head self threading screw supplied with product. No pre -drilling required. Ordering: Specify CPVC pipe size, figure number and description. Fig. A Fig. B FIG.187: DIMENSIONS (IN) • WEIGHT (LBS) CPVC Pipe Size A B ttC E F Max. Hanger Spacing (FT.) Approx. Weight/100 (Ibs) 3/4 1'/ 6 11/2 3/ 6 13/16 21/2 51/2 5 1 1 19/ 6 3/ 6 13/ 6 23/4 6 6 11/4 13/16 13/4 13/ s 113/1s 131/4 1 61/z 7 1 1/2 1'/16 111/ 6 1 3/ 6 1 13/16 1 31/z 1 7 8 2 1'/16 21/8 1 3/ 6 1 13/ 6 1 313/ 6 1 8 9 PROJECTi• rAPPROVAL Project: []Approved Address: ❑ Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-11.19 The 115M Standard Duty Loop Hanger is ideal for suspending stationary, non -insulated pipe lines, including CPVC pipes, in fire sprinkler systems. A knurled insert nut helps simplify vertical adjustments and flared edges on the base (1/2" to 4" sizes) help protect pipes from coming into contact with any sharp edges of the hanger. • Flared edges help prevent any sharp surfaces from coming into contact with the pipe (1/2" to 4" sizes) • Retained insert nut helps ensure the loop hanger and insert nut stay together • Recommended for the suspension of stationary non -insulated pipe lines • Manufactured to use the minimum rod size permitted by NFPA° for fire sprinkler piping • Conforms with Federal Specification WW-H-171 (Type 10), Manufacturers Standardization Society (MSS) SP-58 (Type 10) Material: Steel Finish: Pregalvanized C UL US FM APPROVED Part Number Pipe Size Outer Diameter OD Rod Size RS A B C Static Load F Certifications 1150050EG 1/2" 0.840" 3/8" 213/16" 11/8" 1" 3001b cULus 1150075EG 3/4" 1.050" 3/8" 3" 1 3/16" 15/16" 300 1b cULus, FM 1150100EG 1" 1.315" 3/8" 3 1/4" 1 3/8" 15/16" 300 fb cULus, FM 1150125EG 1150150FG 1 1/4" 1 1/2" 1.660" 1.900" 3/8" 3/8" 3 9/16" 3 13/16" 1 1/2" 1 5/8' 15/16' 15/16" 300 1b 300 fb cULus, FM cULus, FM 1150200EG 2" 2.375" 3/8" 4 1/4" 1 7/8" 15/16" 300 fb cULus, FM 1150250EG 2 1/2" 2.875" 3/8" 5 15/16" 3 7/16" 2" 525 1b cULus, FM 1150300EG 3" 3.500" 3/8" 6 9/16" 3 1/2" 1 15/16" 525 fb cULus, FM 1150350EG 31/2" 4.000" 3/8" 71/16" 33/4" 1 15/16" 58511b cULus, FM 1150400EG 4" 4.500" 3/8" 7 9/16" 4" 1 15/16" 650 1b cULus, FM 1150500EG 5" 5.563" 1/2" 9 13/16" 43/4" 2 1/4" 1,0001b cULus, FM 1150600EG 6" 6.625" 1/2" 11 5/16" 6 5/16" 3 5/16" 1,000 1b cULus, FM 1150800EG 8" 8.625" 1/2" 12 7/8" 6 7/8" 2 7/8" 1,000 fb cULus, FM rn/ent CADDY • One piece break apart strut clamp (1/2" thru 4" pipe size) • Includes thread impression and captured screw (1/2" thru 4" pipe size) • Fits into open side of strut channel • Conforms with Manufacturers Standardization Society (MSS) SP-58 (Type 59) T W OD O 0 �F Part Number 69Q�eL - Finish: EL RIGDO050EG Pipe Size oga 1/2" Outer Diameter —177Width OD W 0.840" 1 1/4" Thickness T 14 GA Static Load F 400 lb RIGDO075EG 3/4" 1.050" 1 1/4" 14 GA 600 lb RIGDO100EG 1" 1.315" 1 1/4" 14 GA 600 lb RIGDO125EG 1 1/4" 1.660" 1 1/4" 14 GA 600 lb RIGDO150EG 1 1/2" 1.900" 1 1/4" 12 GA 8001b RIGD0200FG 2" 2.375" 1 1/4" 12 GA 800 lb RIGDO250EG 2 1/2" 2.875" 1 1/4" 12 GA 800 lb RIGDO300EG 3" 3.500" 1 1/4" 12 GA 800 lb RIGDO350EG 3 1/2" 4.000" 1 1/4" 11 GA 1,0001b RIGDO400EG 4" 4.500" 1 1/4" 11 GA 1,0001b Material: Stainless Steel 304 IFN 1.430 RIGD0050S4 1/2" 0.840" 1 1/4" 14 GA 400 lb RIGD0075S4 3/4" 1.050" 1 1/4" 14 GA 600 lb RIGD0100S4 1" 1.315" 1 1/4" 14 GA 600 lb RIGD0125S4 1 1/4" 1.660" 1 1/4" 14 GA 600 lb RIGD0150S4 1 1/2" 1.900" 1 1/4" 12 GA 800 lb RIGD020OS4 2" 2.375" 1 1/4" 12 GA 800 lb n�6nt CADDY Outer Diameter Width Thickness Static Load Part Number Pipe Size OD W T F RIGD0250S4 2 1/2" 2.875" 1 1/4" 12 GA 800 lb RIGD0300S4 3" 3.500" 1 1/4" 12 GA 800 lb RIGD0400S4 4" 4.500" 1 1/4" 11 GA 1,000lb UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC. WARNING nVent products shall be installed and used only as indicated in nVent's product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. © 2022 nVent All rights reserved nVent, nVent CADDY, nVent ERICO, nVent ERIFLEX and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice. rn/ent CADDY • Recommended for suspending vertical steel pipe risers • Slotted holes make assembly easy, eliminating loose hardware • Serrated flange -head bolts eliminate need for wrenches on both bolt and nut • Conforms with Federal Specification WW-H-171 (Type 8), Manufacturers Standardization Society (MSS) SP-58 (Type 81 OD HS� F 1+ TB A } Part Number MateFial Steel Finish: Pipe Size Electrogalvanized Outer Diameter OD Hole Size HS A B Static Load F Certifications 5100050EG 1/2" 0.840" 7/16" 81/2" 1" 255 lb - 5100075EG 3/4" 1.050" 7/16" 9" 1" 2551b - 5100100EG 5100125EG 1" 11/4" 1.315" 1.660" 7/16" 7/16" 9" 97/16" 1" 1" 255 lb 2551b - - 5100150EG 1 1/2" 1.900" 7/16" 9 7/8" 1" 255 lb - 5100200EG 2" 2.375" 7/16" 10 1/4" 1 3/16" 2551b cULus, ITB 5100250EG 2 1/2" 2.875" 7/16" 11" 1 3/16" 390 1b cULus, ITB 5100300EG 5100350EG 3" 3 1/2" 3.500" 4.000" 7/16" 9/16" 11 3/4" 12 5/8" 1 3/16" 1 3/16" 530lb 670 lb cULus, ITB cULus 5100400EG 4" 4.500" 9/16" 13" 1 1/2" 810lb cULus, ITB 5100500EG 5" 5.563" 9/16" 14 1/2" 1 1/2" 1,160lb cULus 5100600EG 6" 6.625" 9/16" 16" 2" 1,570lb cULus 5100800EG 5101000EG 8" 10" 8.625" 10.750" 11/16" 11/16" 181/4" 20 5/8" 2" 2" 2,500lb 2,500 lb cULus - 5101200EG 12" 12.750" 11/16" 22 3/8" 2" 2,700lb - 5101400EG 5101600EG 14" 16" 14.000" 16.000' 11/16" 13/16" 241/8" 27 7/8" 2" 2 1/2" 2,700lb 2,900lb - - 5101800EG 18" 18.000" 13/16" 29 13/16" 2 1/2" 2,900 lb - 5102000EG 20" 20.000" 13/16" 32 1/4" 2 1/2" 2,900lb - 5102400EG 24" 24.000" 15/16" 36 1/8" 3" 2,900lb - n�6nt CADDY Part Number Pipe Size Outer Diameter Hole Size OD HS A B Static Load F Certifications 5100050HD 1/2" 0.840" 7/16" 81/2" 1" 255 lb - 5100100HD 1" 1.315" 7/16" 9" 1" 255 lb - 5100125HD 11/4" 1.660" 7/16" 97/16" 1" 255 lb - 510015OHD 1 1/2" 1.900" 7/16" 9 7/8" 1" 255 lb - 510020OHD 2" 2.375" 7/16" 10 1/4" 13/16" 255 lb cULus 5100250HD 21/2" 2.875" 7/16" 11" 13/16" 3901b cULus 5100300HD 3" 3.500" 7/16" 113/4" 13/16" 530lb cULus 5100400HD 4" 4.500" 9/16" 13" 11/2" 810lb cULus 5100500HD 5" 5.563" 9/16" 141/2" 11/2" 1,160lb cULus 5100600HD 6" 6.625" 9/16" 16" 2" 1,570lb cULus 5100800HD Material Stainless Steel 8" 304 IEN 1.43011 8.625" 11/16" 181/4" 2" 2,500 lb cULus 510005054 1/2" 0.840" 7/16" 8 1/2" 1" 255 lb - 510007554 3/4" 1.050" 7/16" 9" 1" 255 lb - 510010OS4 1" 1.315" 7/16" 9" 1" 255 lb - 510012554 510015054 1 1/4" 1 1/2" 1.660" 1.900" 7/16" 7/16" 9 7/16" 9 7/8" 1" 1" 255 lb 255 lb - - 510020OS4 2" 2.375" 7/16" 10 1/4" 1 3/16 255 lb - 510025054 2 1/2" 2.875" 7/16" 11" 1 3/16" 3901b - 510030OS4 3" 3.500" 7/16" 11 3/4" 1 3/16" 5301b - 51004COS4 510050OS4 4" 5" 4.500" 5.563" 9/16" 9/16" 13" 14 1/2" 1 1/2" 1 1/2" 810lb 1.160 lb - - 510060OS4 6" 6.625" 9/16" 16" 2" 1,570lb - 510080OS4 8" 8.625" 11/16" 18 1/4" 2" 2,500 lb - 5101000S4 10" 10.750" 11/16" 20 5/8" 2" 2,500 lb - Clamp is fitted for steel pipe and should be installed below a coupling or shear lug, with bolts torqued to recommended value. Slotted holes and bolts for pipe sizes up to 12" only. UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC. WARNING nVent products shall be installed and used only as indicated in nVent's product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. © 2021 nVent All rights reserved nVent, nVent CADDY, nVent ERICO, nVent ERIFLEX and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice. rn/ent CADDY • Conforms with Federal Specification WW-H-171 (Type 23), Manufacturers Standardization Society ANSI°/MSS-SP-58 (Type 19 and 23) A �TQ Fi RS JF1 F2 Material: Cast Iron C&US Fnn vds APPROVED Part Number ish: Plain 3000037PL Rod Size RS 3/8" Flange Thickness FT 3/4" Max A 1 1/8" Torque TQ 5 ft lb Static Load 1 F1 500 lb Static Load 2 F2 250 lb Certifications cULus, FM Standard Packaging Quantity 100 pc 3000050PL 1/2" 3/4" Max 1 1/8" 8 ft to 950 lb 760 lb cULus, FM 50 pc 3000062PL 5/8" 3/4" Max 1 1/8" 5 ft lb 950 lb 760 lb cULus 50 pc 3000075PL 3/4" 3/4" Max 1 1/8" 5 ft lb 950 lb 760 lb cULus 50 pc 3000087PL 7/8" 3/4" Max 1 1/8" 5 ft lb 950 lb 760 lb cULus 50 pc .. 3000037EG 3/8" 3/4" Max 1 1/8" 5 ft to 500 lb 250 lb cULus, FM, 100 pc VdS G4050085 3000050EG 1/2" 3/4" Max 1 1/8" 8 ft lb 950 lb 760 lb cULus, FM 50 pc 3000062EG 5/8" 3/4" Max 1 1/8" 5 ft lb 950 lb 760 lb cULus 50 pc 3000075EG 3/4" 3/4" Max 1 1/8" 5 ft lb 950 lb 760 lb cULus 50 pc 3000087EG 7/8" 3/4" Max 1 1/8" 5 ft lb 950 lb 760 lb cULus 50 pc Setscrew must be tightened and torqued onto the sloped side of the I-beam. Recognizing that torque wrenches are generally not used or available on manyjob sites, the setscrew should be tightened so it contacts the I-beam and then an additional 1/4 to 1/2 turn added. ANSI is a registered trademark of American National Standards Institute. FM is a registered certification mark of FM Approvals LLC, LTD. UL, UR, cUL, CUR, cULus and cURus are registered certification marks of UL LLC. VdS is a registered trademark of VdS Schadenverhutung GmbH. WARNING nVent products shall be installed and used only as indicated in nVent's product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. © 2022 nVent All rights reserved nVent, nVent CADDY, nVent ERICO, nVent ERIFLEX and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice. n�6nt CADDY Bracing & Restraints FCO/7. SEISMIC RESTRAINTS Z /�IVVIL Fig. AF310 (Formerly Afcon Fig. 310) Surge Restrainer Size Range: 1" thru 2" Figure 69, Swivel Ring Hanger Material: Carbon steel Finish: Pre -Galvanized per ASTM A653 Restrainer Service: Prevents vertical movement of horizontal sprinkler piping from thrust loads due to sprinkler activation. The surge restrainer is intended to be installed with Anvil's Figure 69 Swivel Ring Hanger. Restraint Service: May be installed as part of a branch line seismic restraint assembly per the requirements of NFPA 13. The surge restrainer is intended to be installed with Anvil's Figure 69 Swivel Ring Hanger. Approvals: cULus Listed (UL 203 and UL 203a). Complies with the hanging and restraint requirements listed in NFPA 13. Features: • One universal size accommodates Fig. 69 sizes 1" through 2". • Simple design allows for quick installation on existing sprinkler systems. Installation Instructions: Snap surge restrainer onto the Fig. 69 knurl nut. The gap between the surge restrainer and service pipe shall not exceed'/s': Fire Protection applications shall also be installed per the requirements of NFPA 13. Ordering: Specify figure number and description. 3/8 Rod Fig. AF310 Fig. 69 Knurl Nut Fig. 69 Branch Pipe FIG. AF310: LOADS (LBS) • DIMENSIONS (IN) • WEIGHT (LBS) Service Rod UL Max Seismic Restraint Load Approx. Pipe Size Size (UL 203a) Weight/100 1 thru 2 3A 300 4 Surge Restraint Seismic Restraint Assembly Assembly J c @us LISTED Notes: Anvil International® brand bracing components are designed to be compatible ONLY with other Anvil International® brand bracing components, resulting in a Listed seismic bracing assembly. Updated UL listing information may be viewed at www.ut.com Disclaimer: Anvil International (`Anvil") does not provide any warranties and specifically disclaims any liability whatsoever with respect to Anvil bracing products and components that are used in combination with products, parts or systems not manufactured or sold by Anvil. In no event shall Anvil be liable for any incidental, direct, consequential, special or indirect damages or lost profits where non -Anvil bracing components have been, or are used. PROJECTi• rAPPROVAL Project: []Approved Address: ❑ Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-1.18 f� CERTIFICATIONS C UX� UL FEATURES .4CAi FM APPROVED Universal design allows one product to attach directly to concrete, wood, bar joist or I-beam adapters Integrated angle gauge easily displays brace member angle of installation Snap -off bolt head helps enable easy installation and inspection of seismic sway braces Works with 1 " through 2" brace pipes to reduce inventory Low profile minimizes prying effect on concrete fasteners Meets NFPA® 13 as pre -qualified for seismic applications FMOO Specification Tested SPECIFICATIONS Finish ElectrogaIvan ized Material Steel Catalog Hole Size(HS) Width(W) Thickness(T A E D C B UL Listed Number ) Load CSBU1 9/16" 115/16" 3/16" 21/16" 13/4" 11/4" 13/8" 1 5/16" 2,000Ib Catalog Number CSBU2 DIAGRAMS Hole Size(HS) Width(W) 13/16" 1 15/16" Thickness(T A E 3/16' 21/16" 13/4 �A E B + R q T a D S � w WARNING D C g UL Listed Load 11/4" 13/8" 1 5/16" 2,000Ib nVent products shall be installed and used only as indicated in nVent's product instruction sheets and training materials. Instruction sheets are available at www.nvent.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. North America Europe +1.800.753.9221 Netherlands: Option 1 — Customer Care +31 800-0200135 Option 2 — Technical Support France: +33 800 901 793 Europe Germany: 8001890272 Other Countries: +31 13 5835404 APAC Shanghai: + 86 21 2412 1618/19 Sydney: +61 2 9751 8500 CERTIFICATIONS C V�) UL FEATURES HCAi FM APPROVED Use for both lateral and longitudinal sway brace applications Unique slotted holes provide for easy slip-on installation eliminating loose hardware Snap -off bolt head helps enable easy installation and inspection of seismic sway braces Works with 1 " through 2" brace pipes to reduce inventory Meets NFPA®-13 requirements for seismic sway bracing FMOO Specification Tested Meets CEN/TS 17551:2021 requirements for Seismic Sway Bracing SPECIFICATIONS Finish ElectrogaIvan ized Material Steel Brace Pipe Width( Angle( Catalog Number Pipe A B C D Certifications Size Size W) a) CSB0100 1 " 1 " — 2" 1 1/2" 45' CSB0125 1 1 /4" 1" — 2" 1 1/2" 45' CSB0150 1 1/2" 1" — 2" 1 1/2" 45° CSB0200 2" 1" — 2" 1 1/2" 45' CSB0250 2 1/2" 1" — 2" 1 1/2" 45' CSB0300 3" 1" — 2" 1 1/2" 45' CSB0500 5" 1" — 2" 1 1/2" 45' CSB1000 10" V — 2" 1 1/2" 45' CSB1200 12" 1" — 2" 1 1/2" 45' CSB0400 4" 1" — 2" 1 1/2" 45' CSB0600 6" 1" — 2" 1 1/2" 45' CSB0800 8" 1" — 2" 1 1/2" 45' ADDITIONAL PRODUCT DETAILS cUL, UL, OSHPD/HCAI, FM 3 9/16" 1 5/16" 5/8" 5" Approved, Seismic cUL, UL, OSHPD/HCAI, FM 3 9/16" 1 5/16" 11/16" 5 1/2" Approved, Seismic cUL, UL, OSHPD/HCAI, FM 3 9/16" 1 5/16" 3/4" 5 3/8" Approved, Seismic cUL, UL, OSHPD/HCAI, FM 3 9/16" 1 5/16" 13/16" 6" Approved, Seismic cUL, UL, OSHPD/HCAI, FM 3 9/16" 1 5/16" 15/16" 6 3/4" Approved, Seismic cUL, UL, OSHPD/HCAI, FM 3 9/16" 1 5/16" V 7 3/8" Approved, Seismic cUL, UL, OSHPD/HCAI, FM 3 9/16" 1 5/16" 1" 10 1/16" Approved, Seismic cUL, UL, OSHPD/HCAI, FM 3 9/16" 1 5/16" 1" 15 3/16" Approved, Seismic OSHPD/HCAI, FM 3 9/16" 1 5/16" 1" 16 7/8" Approved, Seismic cUL, UL, OSHPD/HCAI, FM 3 9/16" 1 5/16" 1 1/16" 8 1/2" Approved, Seismic cUL, UL, OSHPD/HCAI, FM 3 9/16" 1 5/16" 1 1/8" 10 7/8" Approved, Seismic cUL, UL, OSHPD/HCAI, FM 3 9/16" 1 5/16" 1 1/4" 13'' Approved, Seismic FM® Specification Tested for 1-1/2" to 4" pipe sizes using no hub cast iron pipe. Load ratings for Sch 10 may also be applied to AS 1074 Medium, GB/T 3091, EN 10255 (Medium or Heavy), and JIS G3452 pipe. Load ratings for Sch 40 may also be applied to AS 1074 Heavy, GB/T 3091, EN 10255 (Heavy), and JIS G3454 pipe. Load ratings for FM approved lightwall may also be applied to AS 1074 Lightwall, EN 10255 L,-EN 10220, and GB/T 8163 pipe. DIAGRAMS �A a (Cy 1 T o� � --i w if 2 WARNING nVent products shall be installed and used only as indicated in nVent's product instruction sheets and training materials. Instruction sheets are available at www.nvent.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. North America +1.800.753.9221 Option 1 — Customer Care Option 2 — Technical Support Europe Netherlands: +31 800-0200135 France: +33 800 901 793 Europe Germany: 8001890272 Other Countries: +31 13 5835404 APAC Shanghai: + 86 21 2412 1618/19 Sydney: +61 2 9751 8500 CERTIFICATIONS c UXL L FEATURES Accepts 3/8" or 1/2" (M10 or M12) threaded rod Quick grip clamp simplifies measuring and cutting of threaded rod Eliminates need to cut threaded rod to exact dimensions Works with rough -cut threaded rod and eliminates pipe -side deburring Can be installed with threaded rod above or below the service pipe Shear -off head helps ensure correct torque and simplifies inspection SPECIFICATIONS FM APPROVED Finish ElectrogaIvan ized Material Steel Catalog Number Pipe Size Outer Diameter(OD) Rod Size(RS) Width(W) Height(H) Length(L) CSBBRP0100EG 1" 1.320" 3/8", 1/2" 0.880" 6.670" 1.630" CSBBRP0125EG 1 1/4" 1.660" 3/8", 1/2" 0.880" 7.560" 1.970" CSBBRP0150EG 1 1/2" 1.900" 3/8", 1/2" 0.880" 8.200" 2.210" Catalog Number Pipe Size Outer Diameter(OD) CSBBRP0200EG 2' 2.380" Rod Size(RS) Width(W) Height(H) 3/8", 1/2" 0.880' 9.450" Length(L) 2.690'' DIAGRAMS RS T I OD H — WARNING nVent products shall be installed and used only as indicated in nVent's product instruction sheets and training materials. Instruction sheets are available at www.nvent.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. North America +1.800.753.9221 Option 1 — Customer Care Option 2 — Technical Support Europe Netherlands: +31 800-0200135 France: +33 800 901 793 Europe Germany: 8001890272 Other Countries: +31 13 5835404 APAC Shanghai: + 86 21 2412 1618/19 Sydney: +61 2 9751 8500 CERTIFICATIONS UL FEATURES FM APPROVED Swivel barrel nut accepts 3/8" or 1/2" (M10 or M12) threaded rod Attaches to wood or concrete where cracked concrete approval is not needed SPECIFICATIONS Catalog Number Materia Finish CSBBRS2EG Steel Electrogalvanized ADDITIONAL PRODUCT DETAILS Rod Length(L Height(H Screw Screw Size(RS Width(W) Diameter Length( (Sc) L) 3/8 ' 1.590" 1.110" 1.060" 1 /4" 1 3/4" 1/2" Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. Drill Bit Diameter 3/16" DIAGRAMS S� CADDY• CHINS H RS L W WARNING nVent products shall be installed and used only as indicated in nVent's product instruction sheets and training materials. Instruction sheets are available at www.nvent.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. North America +1.800.753.9221 Option 1 — Customer Care Option 2 — Technical Support Europe Netherlands: +31 800-0200135 France: +33 800 901 793 Europe Germany: 8001890272 Other Countries: +31 13 5835404 APAC Shanghai: + 86 21 2412 1618/19 Sydney: +61 2 9751 8500 Valves & Accessories FireLock° Check Valves Series 717 Check Valve ✓ctaulic® Series 717H High Pressure Check Valve 10.08 Series 717H High Pressure Check Valve Series 717 Series 717 (2 — 3'YDN50 — DN80) (21h — 3773 mm — DN80) (4 — 12YDN100 — DN300) 1.0 PRODUCT DESCRIPTION Available Sizes • 2 — 37DN50 — DN80 (Series 717H) • 21/2 — 12773 mm — DN300 (Series 717) Pipe Material • Carbon Steel, Schedule 10, Schedule 40. For use with alternative material please contact Victaulic. Maximum Working Pressure • Up to 365 psi/2517 kPa/25 bar • Working pressure dependent on pipe size, valve size and approval requirements. Application • Designed for use in Fire Protection systems. • Prevents back flow. • Single -disc mechanism incorporates a spring -assisted feature for non -slamming operation. • Can be installed either vertically (flow upwards only) or horizontally. • Valve body cast with arrow indicator to assist with proper valve orientation. • Optional upstream and downstream pressure taps included on select sizes. See Section 3.0. • Provided with grooved ends. • Rated for ambient temperature use in fire protection systems. Available End Connections • Victaulic Original Groove System (OGS) standard groove 2.0 CERTIFICATION/LISTINGS cQDS FM udS OLPCB LISTED LP 6 1166: Issue 3.1 C6rt/LPCD Ref. 106h/01 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. victaulic.com 10.08 1479 Rev V Updated 11/2021 © 2021 Victaulic Company. All rights reserved. 1 ictaulicr victaulic.com 2.0 CERTIFICATION/LISTINGS Approvals/Listings Series 717H Size Approval/Listing Service Pressures Actual Outside Nominal Diameter cULus FM LPCB VdS CCCf inches inches psi psi psi psi psi D N mm kPa kPa kPa kPa kPa 2 2.375 365 365 365 363 N/A DN50 60.3 2517 2517 2517 2500 2 Y2 2.875 365 365 365 363 N/A 73.0 2517 2517 2517 2500 3.000 365 365 365 363 363 DN65 76.1 2517 2517 2517 2500 2500 3 3.500 365 365 365 363 363 DN80 88.9 2517 2517 2517 2500 2500 Series 717 Size Approval/Listing Service Pressures Actual Outside Nominal Diameter cULus FM LPCB VdS CCCf inches inches psi psi psi psi psi DN mm kPa kPa kPa kPa kPa 2 Y2 2.875 250 N/A N/A N/A N/A 73.0 1725 3.000 250 232 N/A N/A N/A DN65 76.1 1725 1600 3 3.500 250 232 N/A N/A N/A DN80 88.9 1725 1600 4 4.500 365 365 365 363 363 DN100 114.3 2517 2517 2517 2500 2500 5.500 365 365 365 363 363 DN125 139.7 2517 2517 2517 2500 2500 5 5.563 365 365 365 N/A N/A 141.3 2517 2517 2517 6.500 365 365 365 363 N/A 165.1 2517 2517 2517 2500 6 6.625 365 365 365 363 N/A DN150 168.3 2517 2517 2517 2500 8 8.625 365 365 348 247 363 DN200 219.1 2517 2517 2400 1700 2500 10 10.750 250 250 250 N/A 232 DN250 273.0 1725 1725 1725 1600 12 12.750 250 250 250 N/A N/A DN300 323.9 1725 1725 1725 10.08 1479 Rev V Updated 11/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com ✓ctauhcr victaulic.com 3.0 SPECIFICATIONS — MATERIAL Body: L Ductile Iron conforming to ASTM A536, Grade 65-45-12. E Body Coating: ❑ Series 717H Body: Black Paint ❑ Series 717H Endface: Electroless Nickel conforming to ASTM B733 Series 717 (21/2 — 3"/73mm — DN80): PPS Coating ❑ Standard: Series 717 (4 — 12"/DN100 — DN300): Black Paint Optional: Series 717 (4 — 12"/DN100 — DN300): PPS Coating ❑❑ Body Seat: Series 717H: Nitrile 0-ring installed into an Electroless Nickel plating conforming to ASTM B733 Series 717 (21/2" — 3773 mm — DN80): PPS Coated Ductile Iron ❑ Series 717 (4 — 12"/DN100 — DN300): Ductile Iron with Electroless Nickel plating conforming to ASTM B733 ❑ Disc Seal or Coating: (specify choice') Nitrile (Series 717H only) EPDM NOT COMPATIBLE FOR PETROLEUM SERVICES. F i Discs: ❑ Series 717H: CF8M Cast Stainless Steel Series 717 (21/2 — 3773 mm — DN80): Aluminum bronze with elastomer seal ❑ Series 717 (4 — 12"/DN100 — DN300): Elastomer encapsulated disc. ❑ Shaft: ❑ Series 717H: Brass Series 717 (21/2 — 3773 mm — DN80): Type 416 Stainless Steel Series 717 (4 — 127DN100 — DN300): Type 316 Stainless Steel El Spring: Type 302/304 Stainless Steel Shaft Plug: LJ Series 717H: Carbon Steel Zinc Plated Series 717: Carbon Steel Zinc Plated ❑ Pipe Plug: ❑ Series 717H: Carbon Steel Zinc Plated Series 717: Carbon Steel Zinc Plated ❑ Optional Pressure Taps: ❑ Series 717H: Available on all sizes Series 717: Available on sizes 4 — 12"/DN100 — DN300 10.08 1479 Rev V Updated 11/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 3 ✓ctaulicr victaulic.com 4.0 DIMENSIONS Series 717H Typical 2 - 3750 - 80 mm Size Dimensions Weight Actual Outside E to E Nominal Diameter A B C E J R Approx. (Each) inches inches inches inches inches inches inches inches lb DN mm mm mm mm mm mm mm kg 2 2.375 8.66 6.46 3.23 3.02 2.80 4.25 10.7 DN50 60.3 220 165 83 77 72 108 4.9 2 Y2 2.875 9.37 6.94 3.31 3.40 3.38 4.38 13.8 73.0 238 177 85 87 86 112 6.3 3.000 9.37 6.94 3.31 3.40 3.38 4.38 13.8 DN65 76.1 238 177 85 87 86 112 6.3 3 3.500 9.62 7.44 3.53 3.65 3.38 4.63 20.0 DN80 88.9 244 189 90 93 86 118 9.1 10.08 1479 Rev V Updated 11/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com ✓ctauhcr victaulic.com 4.1 DIMENSIONS Series 717 Typical 2 lh - 3773 mm - DN80 A�� R I,� P - - C D 110, E p K, 2 1T Yz" NPT Upstream Drain '/2" NPT Downstream Drain 0 2" NPT (Drain Optional) Typical 4 - 87DN100 - DN200 Us- 'll� III III II � O (1) 1/2" NPT Upstream Drain ® MY' NPT Downstream Drain Typical 10 - 12"/DN250 - DN300 Size Dimensions Weight Actual Outside E to E Approx. Nominal Diameter A B C E J K P R (Each) inches inches inches inches inches inches inches inches inches inches lb DN mm mm mm mm mm mm mm mm mm kg 21h 2.875 3.88 4.26 3.57 - - - - - 3.6 73.0 99 109 91 - - - - - 1.6 3.000 3.88 4.26 3.57 - - - - - 3.6 DN65 76.1 99 108 91 - - - - - 1.6 3 3.500 4.25 5.06 4.17 - - - - - 4.5 DN80 88.9 108 129 106 - - - - - 2.0 4 4.500 9.63 6.00 3.88 3.50 2.00 4.50 3.50 3.35 20.0 DN100 114.3 245 152 99 89 51 114 89 85 9.1 5.500 10.50 6.80 4.50 4.17 2.15 5.88 4.08 3.98 27.0 DN125 139.7 267 173 114 106 55 149 104 101 12.2 5 5.563 10.50 6.80 4.50 4.17 2.15 5.88 4.08 3.98 27.0 141.3 267 173 114 106 55 149 104 101 12.2 6.500 11.50 8.00 5.00 4.50 2.38 6.67 4.73 3.89 38.0 165.1 292 203 127 114 60 169 120 99 17.2 6 6.625 11.50 8.00 5.00 4.50 2.38 6.67 4.73 3.89 38.0 DN150 168.3 292 203 127 114 60 169 120 99 17.2 8 8.625 14.00 9.88 6.06 5.65 2.15 8.85 5.65 5.75 64.0 DN200 219.1 356 251 154 144 55 225 144 146 29.0 10 10.750 17.00 12.00 7.09 6.69 2.15 10.92 6.73 - 100.0 DN250 273.0 432 305 180 170 55 277 171 - 45.4 12 12.750 19.50 14.00 8.06 7.64 2.51 12.81 7.73 - 140.0 DN300 323.9 495 356 205 194 64 325 196 - 63.5 10.08 1479 Rev V Updated 11/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 5 ✓ctauhcr victaulic.com 5.0 PERFORMANCE Flow Characteristics The charts below express the flow of water at 60°F/16°C through valve. Formulas for Cv/Kv values: AP = Qz Where: K 2 Q = Flow (GPM) V AP = Pressure Drop (psi) Q = CV x AP CV = Flow Coefficient Series 717H Size Flow Characteristics Actual Outside Nominal Diameter Full Open inches inches Cv DN mm K� 2 2.375 160 DN50 60.3 138 2 Yz 2.875 215 73.0 186 3.000 215 DN65 76.1 186 3 3.500 315 DN80 88.9 272 Series 717 Size Flow Characteristics Actual Outside Nominal Diameter Full Open inches inches Cv DN mm Kv 2.875 140 73.0 121 3.000 140 DN65 76.1 121 3 3.500 250 DN80 88.9 216 4 4.500 390 DN 100 114.3 337 5.500 700 DN 125 139.7 606 5 5.563 700 141.3 606 6.500 1000 165.1 865 6 6.625 1000 DN 150 168.3 865 8 8.625 1800 DN200 219.1 1557 10 10.750 3000 DN250 273.0 2595 12 12.750 4200 DN300 323.9 3633 AP = Q2 Where: K 2 Q = Flow W/hr) V AP = Pressure Drop (Bar) Q = KV x AP KV = Flow Coefficient 10.08 1479 Rev V Updated 11/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com m ✓ctaulrlo° victaulic.com 5.0 PERFORMANCE (CONTINUED) Flow Characteristics The charts below express the flow of water at 60°F/160C through valve. S717H 10 0.1 100 m IL Y 0. 0 p` 10 ar 10 100 1000 Flow Rate — GPM 100 1000 10000 Flow Rate — Liters/Min. 10.08 1479 Rev V Updated 11/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 7 ✓ctaullc® victaulic.com 5.1 PERFORMANCE Flow Characteristics The charts below express the flow of water at 60°F/160C through valve. S717 10 0.1 1 L 'r �r / r �#- I I i I I 1 1 1 1 1 III I 1 1 1 1 1 III 10 100 1000 10000 100000 Flow Rate — GPM 100 m a Y o. 0 p` 10 a 1 10 IIIIIII III■II■I■■■111 1111111111111 milli ��■■■�III��■ MIN ..111IIII.. IIIII mllliiiiim IIIIIIII■III■II■I■■■■11 mill 100 1000 10000 100000 Flow Rate — Liters/Min. 10.08 1479 Rev V Updated 11/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com ✓ct illc® ES-A-Deringer 30 Job Name Job Location Engineer — Approval — DeringerTM 30 Double Check Detector Assembly Sizes: 2"** - 8" The DeringerTm 30 Double Check Detector Assembly (DCDA-ll) prevents non -health hazard pollutants from entering a potable water supply system when backpressure and/or backsiphonage conditions occur. Used primarily on fire sprinkler systems when monitoring of unauthorized water use is required. Features • Integral shutoff valves indoor/outdoor application • 100% stainless steel housing • Tamper -resistant test cocks • Patented Dual-actionTM check modules - Poppet action at low flow - Swing action at high flow • Lead Free` Bronze bypass components • CuFt or gallons bypass meter • DCDA-II single check bypass • Silicone elastomer check discs • Prewired supervisory switches • Flange adapters available • IPS grooved ends Specifications The Deringer 30 Double Check Detector Assembly shall utilize two independent Dual -action check modules and two integral resiliently seated shut-off valves all of which shall be contained within a single rigid valve housing constructed entirely of 304 stainless steel. Both integral shutoff valves shall include pre -wired supervisory tamper switches contained within a weatherproof actuator housing approved for both indoor and outdoor use. Dual -action check modules shall operate as a "poppet style" check under low flow conditions, operate as a "swing style" check under high flow conditions and utilize replaceable silicone elastomer sealing discs. Assembly test cocks shall be handle -less and operate via a tamper resistant actuator. Assembly shall have a single full access service port and cover with an "inline" replaceable elastomer seal. The bypass assembly shall include a meter registering either gallons or cubic feet, a single check valve and required test cocks. Assembly shall be serviceable without special tools and approved for both horizontal and vertical applications. Contractor Approval Contractor's P.O. No Representative OPMHORIZONTAL !a Approved for Fire Protection, Waterworks, Plumbing, and Irrigation Applications. Materials Valve Housing: 304 Stainless Steel Valve Cover: 304 Stainless Steel SOV Disks: EPDM/304SS SOV Shafts: 304 Stainless Steel Bypass Spring 302 Stainless Steel SOV Bearings: Teflon° fluoropolymer/Bronze Non -wetted Bolts: Grade 8 Zinc Plated Check Disks: Silicone (NSF) Wetted Fasteners: 18-8 Stainless Steel Bypass Components: Lead Free Bronze Check Springs: 17-7 Stainless Steel Check Pins: 17-7/18-8 Stainless Steel Check Seats: Noryl° Polymer (NSF) O-rings: Buna-N (NSF) Bypass Internals: ABS Polymer (NSF) Pressure — Temperature Temperature Range: 33°F -140°F Working Pressure: 10-175psi 'The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. Teflon® is a registered trademark of The Chemours Company. Noryl® is a registered trademark of SABIC Global Technologies B.V. The information contained herein is not intended to replace the full product installa- tion and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. Ames Fire & Waterworks product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measure- ments, please contact Ames Fire & Waterworks Technical Service. Ames Fire & Waterworks reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligafion to make such changes and modificafions on Ames Fire & Waterworks products previously or subsequently sold. A M E FIRE & WATERWORKS A WATTS Brand Flow Performance 379 757 1136 1514 1893 18 a 16 14 12 J 10 N 8 6 cn 4 2 N 00 3" = Rated Flow A = UL Tested O = 15 fps 2271 2650 3028 124 110 96 83 69 55 41 28 14 (kPa) 0 100 200 300 400 500 600 700 800 Specific orientation &agency flow characteristics available on website Rate of Flow (gpm) _ 1pm) 1514 3028 4542 6056 7571 9085 9 16 a 14 12 0 10 J 8 6 4 2 0 0 400 800 1200 Specific orientation & agency flow characteristics available on website Standards AWWA C510-07 Compliant NSF/ANSI 372, UL CERTIFIED LEAD FREE End Connections - IPS Groove for Steel Pipe: AWWA C606 - Flange Adapters: ANSI 1316.1 Class 125 �P,SSIFj� APPROVED C, Ls ft55E U S C APPROVED 1015 A M E S FIRE & WATERWORKS A WATTS Brand ES-A-Deringer 30 1951 Dimensions - Weights o 83 69 55 , 14 Rate of • •• 2 (2Y2)- 30 1 7.1 180 2.9 74 22.3 566 0.0 0 10.0 254 1 11.0 279 52 24 2'/2 30 7.1 180 2.9 74 18.7 475 0.0 0 10.0 254 11.0 279 47 21 3 30 7.4 188 2.9 74 18.7 475 0.0 0 10.3 262 11.0 279 49 22 4 30 7.9 201 3.1 79 18.7 475 0.2 5 11.0 279 11.0 279 51 23 6 30 10.1 257 4.5 114 25 726 1.0 25 14.6 370 16.9 429 99 45 8 30 10.4 264 5.4 137 31.0 787 1.8 46 15.8 401 13.8 351 150 68 "2" size utilizes a 2 1/2" assembly with 2 1/2" groove to 2" female NPT adapter and couplings. Adapter and couplings ship unassembled. USA: Backflow T: (978) 689-6066 • F: (978) 975-8350 • AmesFireWater.com USA: Control Valves T: (713) 943-0688 • F: (713) 944-9445 • AmesFireWater.com Canada: T: (905) 332-4090 • F: (905) 332-7068 • AmesFireWater.ca Latin America: T: (52) 55-4122-0138 • AmesFireWater.com 0 2020 Watts Single Clapper, Siamese Straight F P P g pp g Description The Straight Pattern Fire Department Connection is UL Listed and FM Approved. Manufactured from solid brass* components to increase service life. The single clapper design features brass clapper and brass seats within a cast brass body. The 21/2" inlets are pin lug design for ease of use and compatibility with local fire service districts. Swivel gaskets are included. Breakable caps or plugs should be installed to protect threads and prevent debris from being accidently introduced into the water way. Installation Installation of the Fire Department Connection is achieved with readily available jobsite tools. Prior to installation make sure the proper identification sign has been installed on the nipple. Coat male threads of 4" IPS nipple liberally with a suitable pipe thread sealant such as PipeFit°. Tighten FDC one full turn past hand tight. Make sure FDC is aligned according to requirements. DO NOT OVER TIGHTEN. OVERTIGHTENING MAY CAUSE SEVERE STRETCHING AND POSSIBLE CRACKING OF THE OF THE FDC BODY. The information above is believed to be reliable and accurate, but meant for reference only. FPPI and its agents cannot be held responsible or liable for incidental or consequential damages or loss suffered by any person as a result of the use or misuse of any of the information or its product by any person whose methods and qualifications are beyond our control. It is the user's responsibility to assure that products and methods of use are suitable for the intended purpose, and the preparation prior to installation, and the installation is executed properly and according to existing code, regulations where applicable and accepted industry practices. If you are not trained on the installation of this product, seek guidance from a qualified installer. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 + 1 (760) 599-1168 + 1 (800) 344-1822 + 1 (800) 344-3775 FAX Specifications Size: 4" IPS Outlet (2) 21/2" Inlets Type: Straight Pattern Material: B16 Brass* Finishes: Rough Brass Polished Chrome** Pin Lugs: NST 3.0686 x 71/2 T BCT 3.0000 x 8 TP CF 2.9900 x 71/2 T CIN-new 3.0580 x 6 TP CIN-old 3.0930 x 6 TP CLV 3.0780 x 8 TP Dayton 3.2340 x 6 TP DET 3.1250 x 71/2 T NovaSco 3.2300 x 5 TP NYFD 3.0300 x 8 TP ONT 3.1250 x 5 TP PHX 3.0620 x 6 TP QST 3.0310 x 7 TP Raleigh 3.3400 x 6 TP Richmon 3.3120 x 8 TP TEM 3.0750 x 6 TP Approvals: UL Listed 300psi FM Approved 300psi "Contains lead. Not for use in water systems intended for human consumption. © 2016 Fire Protection Products, Inc. UL FM "Polished chrome finish Only LISTED APPROVED available for NST pin lugs. Identification Signs F P P I Description Fire Protection Products, Inc. FDC Wall Plates are for identifying automatic sprinkler, standpipe and combination fire department connections for the fire service. Manufactured from aluminum (red finish), rough brass (also available in polished chrome finish), or plastic (red finish), they are durable and fade resistant. Installation Round plates are installed around the pipe and are available for either 4" or 2 1/2" IPS. Square shaped signs are mounted directly to the wall. Configuration ITEM NUMBER I SIZE I INSCRIPTION Specifications Material: Plastic, Aluminum, Rough Brass, Chrome Plated Brass Size: 4" IPS MATERIAL 21/2" IPS 4" x 8" 09-507-00 09-508-00 09-509-00 09-510-00 09-510-10 09-514-00 09-516-00 09-520-00 09-522-00 4" IPS AUTO SPKR PLASTIC AUTO SPKR ALUMINUM FIRE DEPT CONN ALUMINUM AUTO SPKR ROUGH BRASS AUTO SPKR POLISHED CHROME STANDPIPE ALUMINUM STANDPIPE -AUTO SPKR ALUMINUM AUTO SPKR ROUGH BRASS AUTO SPKR ALUMINUM 4" IPS 4" X 8" 4" IPS 4" IPS 4" IPS 4" IPS 21/2" IPS 21/2" IPS The information above is believed to be reliable and accurate, but meant for reference only. FPPI and its agents cannot be held responsible or liable for incidental or consequential damages or loss suffered by any person as a result of the use or misuse of any of the information or its product by any person whose methods and qualifications are beyond our control. It is the user's responsibility to assure that products and methods of use are suitable for the intended purpose, and the preparation prior to installation, and the installation is executed properly and according to existing code, regulations where applicable and accepted industry practices. If you are not trained on the installation of this product, seek guidance from a qualified installer. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 + 1 (760) 599-1168 + 1 (800) 344-1822 + 1 (800) 344-3775 FAX 0 2017 Fire Protection Products, Inc. Breakable Caps, Metal F P P Description The Metal Breakable Caps for Fire department Connections are cast aluminum. Each set includes two caps and 4 eyelets with nuts for 21/2" swivels. The caps have been molded with "scored" tabs for easy removal with a hydrant wrench or other similar tool. Metal Breakable caps provide inexpensive protection against the introduction of foreign material into the swivels but allow for quick access when a hose connection is necessary. Installation Remove the caps from their packaging. Hold the breakable cap to the opening of swivel. Align the breakable tans with the pin lugs on the swivel. Once aligned, insert the threaded end of one eyelet through the hole in the tab of the cap then slide the eyelet over the pin lug. Once the eyelet is in place, carefully thread the included'/4-20 finished hexnut on to the threaded end of the eyelet until snug. Caution: Do not overtighten. The tabs of the break caps are designed to break with minimal force. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 0 2012 Fire Protection Products, Inc. Specifications Material: Cast Aluminum Size: 2'/2" 3" Type: Pin lug Color: Red Green Yellow Included per set: (2) caps (4) eyelets (4) finished hexnuts Available in sets only Victaulic° Series UTD ✓ctaulli Universal Test and Drain 30.73 P 1.0 PRODUCT DESCRIPTION Available Sizes • 1 — 27DN25 — DN50 Pressure Class • Up to 300 psi/2068 kPa/21 Bar Test Orifice K-Factor • IVDN25 - K2.8 (4.0) • 1 1/dYDN32 — K4.2 (6.0) • 27DN50 — K5.6 (8.1) Available Connections • 1VDN25 — NPT/IGS • 1 1/d'/DN32 — NPT/OGS • 27DN50 — NPT/OGS Ports • (2) Integrated ports with clear Polycarbonate plugs, allowing for a visual indication water is flowing Standard: • Preinstalled Series ARV (refer to publication 30.75) and plastic tubing. 2.0 CERTIFICATION/LISTINGS 3.0 SPECIFICATIONS - MATERIAL 3 Way Test and Drain Body: Brass UTD Test and Drain Ball: Chrome -plated brass UTD Test and Drain Handle Stem: Stainless Steel 3-Way Test and Drain Stem 0-Ring: EPDM UTD Test and Drain Seal: PTFE Sight Glass: Polycarbonate 3-Way Red Handle: EPDM Retaining Nut: Stainless Steel ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. 30.73 15917 Rev A Updated 06/2021 © 2021 Victaulic Company. All rights reserved. 1 /ctaulli victaulic.com 4.0 DIMENSIONS Size Dimensions Weight Actual Outside Approximate Nominal Diameter A B C D E (Each) inches inches inches inches inches inches inches lb DN mm mm mm mm mm mm kg 1 1.315 4.88 3.25 1.88 4.13 2.13 3.3 DN25 33.7 124 83 48 105 1 54 1.5 1 1/4 1.660 5.00 3.38 2.25 4.88 2.63 4.6 DN32 42.4 127 86 57 124 67 2.1 2 2.375 5.50 3.75 2.75 6.00 3.38 8.2 DN50 60.3 140 95 70 152 86 3.7 30.73 15917 Rev A Updated 06/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com ✓ctaulic victaulic.com 5.0 PERFORMANCE Size Actual Outside Maximum Nominal Diameter Working Pressure inches inches psi DN mm kPa 1 1.315 300 1 1/4 1 1.660 1 300 2.375 1 300 6.0 NOTIFICATIONS A WARNING • Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS 30.71: Series UM Universal Manifold Assembly 30.72: Series UMC Universal Manifold Control Assembly 10.54: FireLockTM Innovative Groove System I IGSTM 10.64: FireLockTM Installation -Read yTm Rigid Couplings Style 009N and Style 109 30.74: Series ARV Adjustable Relief Valve User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end -use application, in accordance with industry standards and project specifications, as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 30.73 15917 Rev A Updated 06/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 3 ✓ctaulilc Alarms & Supervisory Devices Bourdon Tube Pressure Gauges Standard Series Type 111.10SP Applications ■ Fire sprinkler systems ■ Suitable for all media that will not obstruct the pressure system or attack copper alloy parts Product Features ■ UL-listed (UL-393), United States and Canada ■ Factory Mutual (FM) approved ■ Reliable and economical Specifications Design EN 837-1 & AS ME B40.100 Sizes 4" (100 mm) Accuracy class ± 3/2/3% of span (ASME B40.100 Grade B) Ranges 0/80 psi (5,5 bar), retard to 250 psi (17 bar), air 0/300 psi (20 bar), water 0/400 psi (28 bar), water 0/600 psi (40 bar), water Working pressure Steady: 3/4 of full scale value Fluctuating: 2/3 of full scale value Short time: full scale value Operating temperature Ambient: -40°F to 140°F (-40°C to 60°C) Media: 140°F (+60°C) maximum Temperature error Additional error when temperature changes from reference temperature of 68°F (20°C) ±0.4% of span for every 18°F (10°K) rising or falling. WIKA Datasheet 110.10SP • 3/2019 WIKA Datasheet 111.10SP .` 150 100sPRirnc 200 -- WAT =50 250—= 300 FM -' WOK •'®• APPROVED C UL US LISTED Bourdon Tube Pressure Gauge Type 111.10SP Bourdon tube Material: copper alloy C-shape Pressure connection Material: copper alloy 1/4" NPT lower mount (LM) Movement Copper alloy Dial White aluminum with stop pin; black and red lettering Pointer Black aluminum Case Black polycarbonate Window Snap -in clear polycarbonate Approvals UL listed (UL-393) Factory Mutual Page 1 of 2 WIKA Optional Extras (not all options are UL or FM approved) Dimensions ■ Brass restrictor ■ Black -painted steel case ■ Custom dial layout ■ Other dual scales in combination with psi are available: bar, kPa, MPa, kg/cm2 4" mm 100 71 30 11.5 3.75 in 4.0 2.79 1.18 0.45 0.15 1/4" Ordering information Pressure gauge model / Nominal size / Scale range / Size of connection / Optional extras required Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Modifications may take place and materials specified may be replaced by others without prior notice. 14 0.55 0.35 lb. L L I� E W(sq) T(NPT) Page 2 of 2 WIKA Datasheet 111.10SP • 3/2019 WIKA WIKA Instrument Corporation 1000 Wiegand Boulevard Lawrenceville, GA 30043-5868 Tel: 888-WIKA-USA • 770-513-8200 Fax: 770-338-5118 E-Mail: info@wika.com www.wika.com POTTER The Symbol of Protection Specifications subject to change without notice. Ordering Information Nominal Pipe Size Model Part Number 2" DN50 VSR-2 1144402 21/2" DN65 VSR-2 1/2 1144425 3" I DN80 VSR-3 1144403 3 1/2" VSR-3 1/2 1144435 4" I DN100 VSR-4 1144404 5" VSR-5 1144405 6" I DN150 VSR-6 1144406 8" DN200 VSR-8 1144408 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD UL, CUL and CSFM Listed, FM Approved, LPCBApproved, For CE Marked (EN12259-5) / VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. • Temperature Range: 40°F-120°F, (4.5°C - 49°C) - UL • Non -corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 _AWARNIN • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. CAUTION Waterflow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Important: This document contains important information on the installation and operation of the VSR waterflow switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. General Information Enclosure The Model VSR is a vane type waterflow switch for use on wet sprinkler The VSR switches and retard device are enclosed in a general purpose, systems. It is UL Listed for use on a steel pipe; schedules 5 through 40, die-cast housing. The cover is held in place with two tamper resistant sizes 2" - 6" and is UL Listed and FM Approved for use on steel pipe; screws which require a special key for removal. A field installable schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC cover tamper switch is available as an option which may be used approved sizes are 2" thru 8" (50 turn thru 200 mm). See Ordering to indicate unauthorized removal of the cover. See bulletin number Information chart. 5401103 for installation instructions of this switch. The VSR may also be used as a sectional waterflow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. #5401146 - REV M PAGE 1 OF 4 11115 (E)POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterflow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow. Take care not to damage the non -corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1). The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. Do not obstruct or otherwise prevent the trip stem of the flow switch from moving when water flows as this could damage the flow switch and prevent an alarm. If an alarm is not desired, a qualified technician should disable the alarm system. Fig. 1 Retard Adjustment DO NOT LEAVE COVER OFF FOR AN EXTENDED PERIOD OF TIME The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at '61i the minimum required to prevent false alarms DIRECTION OF WATERFLOW TIGHTEN NUTS ALTERNATELY O l V J MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION \ OF WATERFLOW CAUTION Hole must be drilled perpendicular to the pipe and vertically centered Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect - O ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW (Flowing water activates device in one direction only.) DWG. 1146-ti SOmm ADAPTER ADAPTER 20--- MAX. DN50 ONLY USE (2) 5180162 ADAPTERS AS SHOWN ABOVE DWG IW-IF Compatible Pipe/ Installation Requirements Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Hole Size U-Bolt Nuts Torque Lightwall Schedule 10 (UL) Schedule 40 (UL) BS-1387 (LPC) DN (VDS) inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-m VSR-2 2 DN50 2.375 60.3 .065 1.651 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25 + .125/- 062 33.0+2.0 VSR-21/2 2.5 2.875 73.0 .084 2.134 0.120 3.05 0.203 5.16 - - - - VSR-21/2 - DN65 3.000 76.1 - - - - - - 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 .083 2.108 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 2.00+.125 50.8+2.0 20 27 VSR-31/2 3.5 4.000 101.6 - - 0.120 3.05 0.226 5.74 - VSR-4 4 DN100 4.500 114.3 .084 2.134 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR-5 5 - 5.563 141.3 - - 0.134 3.40 0.258 6.55 - - - - VSR-6 6 DN150 6.625 168.3 .115 1 2.921 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 1 DN200 8.625 1 219.1 0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 NOTE: For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MFG. #5401146 - REV M PAGE 2 OF 4 11115 CF. POTTER The Symbol of Protection Fig. 2 To remove knockouts: Place screwdriver at inside edge of knockouts, not in the center. Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig. 3 Break out thin section of cover when wiring both switches from one conduit entrance. Fig. 5 Typical Electrical Connections Notes: 1. The Model VSR has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. 2. For supervised circuits, see "Switch Terminal Connections" drawing and warning note (Fig. 4). rim VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Fig. 4 Switch Terminal Connections Clamping Plate Terminal �i8G0�ING 00"OING owc. #1146-16 A NIN An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8" of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. CONNECTOR NEUTRAL FROM BELL BREAKER NEUTRAL FROM BELL 0 a 1 BREAKER r0 J a v LINE FROM BREAKER 0 EOL (End Of Line Resistor) NOTE: When connecting to a ILL Listed control panel, use the panel's resistor value for circuit supervision. Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. vise the person responsible for testing of the fire protection system that this system must be tested in accordance h the testing instructions. Fig. 6 Mounting Dimensions 3.50 in U-B U-BOLT PIPE PLASTIC 2.00 (50.8 ,IA. in mm) U owo. 114a14 NOMINAL PIPE DIA. +L75 in (+44.5 MM) FOR ON 50 — DN 65 2-2.5 in NOMINAL PIPE DIA. +2.125 in (+54.0 MM) FOR ON 80 — DN 200 3-8 in Fig. 7 GREEN GROUND PRINTED IN USA MFG. #5401146 - REV M 11115 PAGE 3 OF 4 (E)POTTER ® The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterflow switch should provide years of trouble -free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 8). There is no maintenance required, only periodic testing and inspection. Retard/Switch Assembly Replacement (See Fig. 8) The Retard/Switch Assembly is field -replaceable without draining the system or removing the waterflow switch from the pipe 1. Make sure the fire alarm zone or circuit connected to the waterflow switch is bypassed or otherwise taken out of service. 2. Disconnect the power source for local bell (if applicable). 3. Identify and remove all wires from the waterflow switch. 4. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. 5. Remove the retard assembly by lifting it straight up over the tripstem. 6. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. 7. Re -install the (2) original mounting screws. 8. Reconnect all wires. Perform a flow test and place the system back in service. Fig. 8 DO NOT REMO'v (2) RETARD HOL SCREWS Removal of Waterflow Switch REMOVE (2) ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE BREAKOUTTHIN SECTION OF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2) ORIGINAL MOUNTING SCREWS RETARD/SWITCH ASSEMBLY / Li (2) LOCATING PINs� ft (2) LOCATII BOSSES IN DWG# 1146-10 • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterflow detector saddle. • Lift detector clear of pipe. PRINTED IN USA MFG. #5401146 - REV M PAGE 4 OF 4 11115 (E)POTTER h The Symbol of Protection Features • Listed for indoor and outdoor use • Outdoor use requires BBK-1 or HC-BB weatherproof back box • Indoor use mounts directly to standard 4" box • Low current draw • High dB output • AC and DC models • DC models are motor driven, polarized, and have built in transient protection for supervised alarm circuits • Available in 6", 8" and 10" sizes Description These vibrating type bells are designed for use as fire or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 or HC-BB weatherproof backbox for outdoor applications. Weatherproof backbox model BBK- 1 or HC-BB, Stock No. 1500001. Notes 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30' to 150°F (-34° to 66°C) 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to PDC-DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6 (150) 12VDC PDC-6-12 1750500 200mA 96 76 8 (200) 12VDC PDC-8-12 1750502 .200mA 96 77 10 (250) 12VDC PDC-10-12 1750504 .200mA 96 78 6 (150) 1 24VDC PDC-6-24 1750501 .20mA 95 77 8 (200) 24VDC PDC-8-24 1750503 20mA 83 79 10 (250) 24VDC PDC-10-24 1750505 20mA 85 80 6 (150) 24VAC PBA246 1806024* .17A 91 78 8 (200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6 (150) 120VAC PBA1206 1806120* .05A 92 83 8 (200) 120VAC PBA1208 1808120* .05A 99 84 10 (250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. BELLS PBA AC & PDC-DC U U C/ FM ** ��° 9�h APPROVED * ULC on PDC-DC Only ** FM on PBA-AC Only Technical Specifications Dimensions 6" (150mm), 8" (200mm) and 10" (250mm) Cover: Steel Finish: Red Powder Coat Enclosure Base: non -corrosive composite material All parts have corrosion resistant finishes Model BBK-1 or HC-BB weatherproof backbox (optional) 24VAC Voltages Available 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Indoor or outdoor use (See Note 1) Environmental -400 to 150OF (400 to 66°C) Limitations (Outdoor use requires weatherproof backbox.) AC Bells - 4 No. 18 AWG stranded wires Termination DC Bells - 18 AWG stranded wire Service Use NFPA 13, 72, local AHJ *Specifications subject to change without notice. BWARNING I Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. WARNIN In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or HC-BB. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 5400777 - REV A • 12/20 PAGE 1 OF 2 (E)POTTER BELLS The Symbol of Protection PBA AC & PDC-DC Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. 1. Remove the gong. 2. Connect wiring (see Fig. 3). 3. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 4. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 5. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). Weatherproof Backbox Dimensions WARNING Inches (mm) Wtoinstaller down will prevent bell froWringing. MODEL BBK-1 OR HC-BB Fig 2 Bell Dimension Inches (mm) _ Fig 1 53/4" _ (146 mm) 10" (250 mm) 8„ r - I (200 mm) 6" j I5/8" (150 mm) I I 211/16" (68 mm) DWG#776-1 Wiring Rear View Fig 3 D,C. BELLS (OBSERVE POLARITY) A,C, BELLS (86 mm) 4 1/4" (108 mm) 3 3/8" 5" (86 mm) (127 mm) RED (IN) RED (OUT) WHITE (IN) WHITE (OUT) O O FROM CONTROL PANEL CBLIACK EXT BELL FROM CONTROL PANEL OR D-OF-LINE OR PRECEDING BELL SISTOR PRECEDING BELL BLACK (IN) OT) BLACK (IN) O CBLACK CAUTION - WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN, NOTES: CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS. 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY 2. RED WIRES POSITIVE (+). AFTER LAST BELL. 3. BLACK WIRES NEGATIVE (-). 2. END -OF -LINE RESISTOR IS NOT REQUIRED ON AC BELLS . 4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 5400777 - REV A • 12/20 PAGE 2 OF 2 Fire Sprinklers Bulletin 016 January 2022 Reliably Features • Coverage for long and narrow light hazard spaces such as hallways, decks, and rooms • Coverage area up to 28 ft (8.5m) long and 10 ft (3m) deep • Available in four trim styles and a variety of finish combina- tions. Product Description The Reliable Model DH56 Dry Extended Coverage Horizontal Sidewall Sprinkler is a quick -response sprinkler utilizing a sensitive 3mm glass bulb thermal element listed for use in light hazard applications. Dry sprinklers are intended for use on wet, dry, and preaction systems to protect indoor and outdoor areas that are subject to freezing. When used on wet systems, it is important that a minimum exposed length of barrel inside the face of the wall or insulation is provided to offset conduction of potentially freezing temperatures from the unconditioned (sprinkler) end along the barrel. See Figure 6 for guidelines on using dry sprinklers on wet systems. Environments where dry sprinklers are employed are often corrosive. For this reason, Model DH56 dry sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax prevents contaminants from entering the internal portion of the drop nipple and must not be removed. Model DH56 Dry Extended Coverage Horizontal Sidewall Sprinkler cULus Listed DH56 Dry EC HSW with standard escutcheon Application The Model DH56 is a horizontal sidewall dry sprinkler intended for installation in light hazard occupancies in accordance with NFPA 13. These sprinklers are designed to provide fire protection in long and narrow spaces such as hallways, corridors, decks and rooms up to 28 feet (8.5m) wide and 10 feet (3m) deep. Model DH56 sprinklers are rated for 250 psi (17.2 bar) and can be mounted between 4 and 12 inches (102 and 305mm) down from the ceiling. Max. Working Maximum Coverage Area Flow Rate Pressure Sprinkler Sprinkler Model Pressure Width x Length 9pm (L/min) psi (bar) Identification psi (bar) ft x ft (m x m) Number (SIN) 28 x 8 (8.5 x 2.4) 23 (87.1) 16.9 (1.2) DH56 Dry EC 250 (17.2) RA1664 28 x 10 (8.5 x 3) 28 (106) 25(1.7) www.reliablesprinkler.com Technical Specifications Style: Extended Coverage Horizontal Sidewall Threads: 1" NPT or ISO7-1 R1 Nominal K-Factor: 5.6 (80) Max. Working Pressure: 250 psi (17.2 bar) Max. Spacing: 28 ft (8.5m) Min. Spacing: 16 ft (4.9m) Material Specifications Inlet Fitting: Brass Alloy Flip Disk: Brass Alloy Seal: PTFE Coated Belleville Spring Outer Tube: Galvanized Steel Pipe Sprinkler Frame: Brass Alloy Bulb Insert: Copper Alloy Thermal Element: Glass Bulb Deflector: Bronze Alloy Load Screw: Brass Alloy Model DH56 EC HSW Coverage Area Sprinkler Finishes See finish combination tables on following pages Sensitivity Quick Response Temperature Ratings 155°F (68°C) 175°F (79°C) 200-F(93°C) it Recessed Escutcheons/Cover Plates Standard Escutcheon HB Escutcheon FP Escutcheon SWC Cover Plate Listings and Approvals cULus Listed for Light Hazard 28' [8.5m] Maximum Spacing 16' [4.9m] Minimum Spacing Shown here with standard escutcheon. See pages 3-6 for additional trim styles )H56 INKLER 4" [100mm] Min. from Ceiling 12" [300mm] Max. from Ceiling DH56DRYCOVAREA \ 8' [2.4m] or 10' [3m] Based on Selected Discharge Flow and Pressure Bulletin 016 ReliablEc Page 2 of 10 January 2022 www.reliablesprinkler.com Model DH56 Dry Sprinkler with Standard Escutcheon System Tee \ 1_ \� I 016STD 4" [102mm] Min. 12" [305mm] Max. 1/4" [6mm] Nominal Protrusion 1/4" [6mm] Escutcheon Adjustment "A" Dimension: 2" to 48" (50mm to 1200mm) in 1/4" (6mm) increments Finish Combinations: Standard Escutcheon Sprinkler Escutcheon(2)(3) Bronze Polished Stainless Steel Bronze Laquered Brass Chrome Polished Stainless Steel White Polyester)') White Polyester Black Polyester)') Black Polyester Custom Color Polyester(') Custom Color Polyester Electroless Nickel PTFEM Polished Stainless Steel Notes: 1. UL Listed as Corrosion Resistant. 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is 316 stainless steel. 3" Dia. [76mm] Bulletin 016 Reliable Page 3 of 10 January 2022 www.reliablesprinkler.com Model DH56 Dry Sprinkler with HB Escutcheon Ceiling Escutcheon 4" [102 m m ] Min. Sprinkler Can 12" [305 mm] Max. Inlet Fitting 1-15/16 System Tee [49mm] — - — - — - — - — - — - - — - — -- — 5/8" [16 mm] 3-1/2" [89 mm] Dia. if 2 1/2" Dia. [64 mm] Hole in Wall 1-1/4" 1-1/4" [32mm] Nominal 016HB [32mm] Projection 1/2" [13 mm] Escutcheon Adjustment 1/2" [13 mm] Escutcheon Nominal Escutcheon Position Adjustment "A" Dimension "A" Dimension: 3-1/2" to 36" (90mm to 900mm) in 1/4" (6mm) increments Finish Combinations: HB Escutcheon Sprinkler Escutcheon(2)(3) Bronze Chrome Chrome Chrome White Polyester(') White Polyester Black Polyester(') Black Polyester Custom Color Polyester') Custom Color Polyester Electroless Nickel PTFEM Stainless Steel Notes: 1. UL Listed as Corrosion Resistant. 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is cold rolled steel unless noted. Bulletin 016 January 2022 Page 4 of 10 www.reliablesprinkler.com Model DH56 Dry Sprinkler with FP Escutcheon System Tee IT 016FP Escutcheon Sprinkler Cup Inlet Fitting 2 5/8" Dia. [67mm] Hole in Wall 1/4" [6mm] Escutcheon Adjustment "A" Dimension E ling Nom 1 1/4" [32mm] 4" [102mm] Min. 12" [305mm] Max. 5/8" [16mm] 3-1/4 [82mm] —1/4" [6mm] Escutcheon Adjustment Nominal Position of Escutcheon "A" Dimension: 3-1/2" to 48" (90mm to1200mm) in 1/4" (6mm) increments Note: Do not install the Model DH56 Dry Sprinkler with FP recessed escutcheon in locations where there is positive pressure in the cavity behind the sprinkler relative to the pressure at the sprinkler. Finish Combinations: FP Recessed Escutcheon Sprinkler') Escutcheon(3)(4) Bronze Brass Chrome Chrome White Polyester(2) White Polyester Black Polyester(2) Black Polyester Custom Color Polyester(2) Custom Color Polyester Electroless Nickel PTFE(2) Stainless Steel Notes: 1. Cup for FP Recessed is unfinished galvanized steel except electroless nickel PTFE sprinkler uses a stainless steel cup. 2. UL Listed as Corrosion Resistant. 3. Escutcheons do not carry corrosion resistant listings. 4. Base material is cold rolled steel unless noted. Bulletin 016 Reliable Page 5 of 10 January 2022 www.reliablesprinkler.com Model DH56 Dry Sprinkler with SWC Cover Plate Sprinkler Cup System Tee Inlet Fitting I -I - - i I 016SWC 2-5/8" [67mm] Dia. Hole in Wall 1-9/16" [40mm] 4" [102mm] Min 12" [305mm] Max 5/8" [16mm] 3-7/32" Dia. [82mm] 1/4" [6mm] Cover Plate Adjustment 1/4" [6mm] _ Cover Plate Adjustment ' Nominal Position of Cover Plate "A" Dimension "A" Dimension: 3-1/2" to 48" (90mm to1200mm) in 1/4" (6mm) increments Note: Do not install the Model DH56 Dry Sprinkler with SWC cover plate in locations where there is positive pressure in the cavity be- hind the sprinkler relative to the pressure at the sprinkler. Finish Combinations: SWC Concealed Cover Plate Sprinkler(') Cover Plate(2) Bronze White Polyester Chrome Bright Chrome Dull Bright Brass Unfinished Bronze Custom Color Notes: 1. Cup for SWC Concealed is unfinished galvanized steel. 2. Cover plates do not carry corrosion resistant listings. AV Bulletin 016 January 2022 Page 6 of 10 www.reliablesprinkler.com MINIMUM EXPOSED BARREL LENGTH WHEN CONNECTED TO WET PIPE SPRINKLER SYSTEM NOTE: STANDARD DRY PENDENT IS SHOWN, HOWEVER, MINIMUM EXPOSED BARREL LENGTH APPLIES TO ALL STYLES OF DRY SPRINKLERS CONNECTED TO A WET PIPE SYSTEM. WET PIPE AMBIENT TEMPERATURE EXPOSED TO DISCHARGE END OF SPRINKLER*(F EXPOSED BARREL AMBIENT TEMPERATURE 40'F/4'C I 50'F/10'C 60'F/16'C EXPOSED MINIMUM BARREL LENGTH** CE OF FITTING TO TOP OF CEILING)*** IN. (MM) IN. (MM) IN. (MM) 40°F (4'C) 0 0 0 30-F (-1'C) 0 0 0 20°F (-7'C) 4 (100) 0 0 10'F (-12'C) 8 (200) 1 (25) 0 07 (-18'C) 12 (300) 3 (75) 0 —10'F (-23'C) 14 (350) 4 (100) 1 (25) —207 (-29'C) 14 (350) 6 (150) 3 (75) —30-F (-34`C) 16 (400) 8 (200) 4 (100) —40'F (-40'C) 18 (450) 8 (200) 4 (100) —50-F (-46'C) 20 (500) 10 (250) 6 (150) —607 (-51'C) 20 (500) 10 (250) 6 (150) * FOR AMBIENT TEMPERATURES EXPOSED TO THE DISCHARGE END OF THE SPRINKLER THAT OCCUR BETWEEN THE VALUES LISTED, USE THE NEXT COOLER TEMPERATURE. ** THE MINIMUM EXPOSED BARREL LENGTH IS NOT THE SAME AS THE "A" DIMENSION. THE MINIMUM EXPOSED BARREL LENGTH IS BASED ON A PROPERLY SEALED PENETRATION WITH A MAXIMUM WIND VELOCITY ON THE EXPOSED SPRINKLER OF 30 MPH (48 KM/H). LONGER EXPOSED BARREL LENGTHS WILL HELP AVOID FREEZING OF THE WET PIPING WHERE HIGHER WIND VELOCITY IS EXPECTED. * THE MINIMUM EXPOSED BARREL LENGTH IS MEASURED FROM THE FACE OF THE FITTING TO THE INSIDE FACE OF THE INSULATION, WALL, OR CEILING LEADING TO THE COLD SPACE, WHICHEVER IS CLOSEST TO THE FITTING. SYSTEM PIPING MINIMUM EXPOSED BARREL LENGTH DECKTITE FLASHING (SEE ABOVE) RASCO #4003910 (RECOMMENDED) (PROTECTED AREA) \ "'j ' I 1 4 o NOTE: TEE MAY BE IN ANY —t—Ii, ---}�L — ORIENTATION FOR WET PIPE n�iI'II 'ISYSTEMS. L__iPt___�� Lr—] l tJ i IF HUMIDITY AND TEMPERATURE DIFFERENTIAL CAUSES CONDENSATION ON THE EXPOSED DRY SPRINKLER, CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION, FOAM INSULATING TAPE OR EQUIVALENT. MINIMUM (HEATED AREA) SEAL THE CLEARANCE SPACE EXPOSED AROUND THE SPRINKLER TO AVOID BARREL LEAKAGE OF AIR INTO THE PROTECTED LENGTH AREA AND CONSEQUENT FORMATION OF "A" DIMENSION CLEARANCE HOLE CONDENSATE AROUND THE FRAME, WHICH COULD INHIBIT OPERATION OR CAUSE PREMATURE OPERATION. SEE BELOW FOR RECOMMENDED METHODS. ____---_— _—________ INSIDE SURFACE OF ------INSULATION, WALL, OR ______CEILING ______ �iH_z iz ___ ____ _\_\______ THERMAL `ESCUTCHEON BARRIER DISCHARGE END OF SPRINKLER PROTECTED (NON —CONDITIONED) AREA RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS (DRY SPRINKLER WITH STANDARD ESCUTCHEON SHOWN) -------- —r rt— --#--- a, (HEATED AREA (HEATED AREA) INSIDE FACE zlz [SEAL CLEARANCE .. .... HOLE .. . .......... ... .. . .'................. INSULATED .......................... FREE OR COOLER STRUCTUZER, RE OR EXTERIOR ... ...... FRAMING .... ....... DISCHARGE END OF DRY SPRINKLER IN COLD AREA PIPING MINIMUM EXPOSED BARREL LENGTH (SEE ABOVE) (PROTECTED AREA) DISCHARGE END OF DRY SPRINKLER i IN COLD AREA COMDRYDETII Bulletin 016 ReliablE� Page 7 of 10 January 2022 www.reliablesprinkler.com *CAUTION* RELIABLE DRY SPRINKLERS MAY BE INSTALLED IN A LISTED CPVC SPRINKLER FITTING, ONLY UPON VERIFICATION THAT THE FITTING DOES NOT INTERFERE WITH THE SPRINKLER'S INLET. Do not install dry sprinklers with standard inlets into CPVC fittings that have an internal obstruction; this will damage the sprinkler, the fitting, or both. Short inlet ("PL") versions of Reliable dry sprinklers are available that may or may not be compatible with fittings having internal obstructions in existing installations. Sprinklers with the short inlet ("PL") should only be installed in CPVC fittings of wet -pipe systems. In all cases, verify sprinkler and fitting dimensions prior to installation to avoid interference. Internal "struction Female Pipe Thread Female Pipe Thread CPVC Fitting with Internal Obstruction 1 Shorter Inlet Male Pipe Thread Dry Sprinkler Short Inlet ("PL Longer Inlet Male Pipe Thread No Internal ^'- Struction No Internal Obstruction Dry Sprinkler Standard Inlet BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION Bulletin 016 Reliable Page 8 of 10 January 2022 www.reliablesprinkler.com Installation (General) Dry sprinklers connected to wet pipe systems must be installed as indicated in Figure 6 and as required by NFPA 13 with the Exposed Minimum Barrel Length located in a heated area. Reliable Model DH56 dry sidewall sprinklers may be installed in ductile or malleable cast iron threaded tees, or CPVC tees and adapters upon verification that the sprinkler inlet fitting does not interfere with the interior of the fitting (see Figure 7). DO NOT install Reliable Model DH56 dry sidewall sprinklers into elbows or couplings, welded outlets, mechanical tees, or gasket sealed CPVC fittings. DH56 HSW with Standard Escutcheon Cut a 2-1/8" (54mm) diameter hole in the wall as shown in Fig. 2. Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench (see Fig. 8) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and sliding the escutcheon over the finished sleeve until tight to the finished surface. DH56 HSW with HB Escutcheon Cut a 2-1/2" (64mm) diameter hole in the wall as shown in Fig. 3. Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench (see Fig. 8) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and sliding the skirt over the finished sleeve until tight to the finished suface. DH56 HSW with FP Recessed Escutcheon Cut a 2-5/8" (67mm) diameter hole in the wall as shown in Fig. 4. Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench (see Fig. 8) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and pushing (or threading) the FP escutcheon into the threaded cup. Final adjustment is made by turning the FP escutcheon clockwise until the flange makes full contact with the wall surface. DH56 HSW SWC Concealed Cover Plate Cut a 2-5/8" (67mm) diameter hole in the wall as shown in Fig. 5. Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench (see Fig. 8) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and pushing (or threading) the SWC cover plate into the threaded cup. Final adjustment is made by turning the cover plate clockwise until the cover plate flange makes full contact with the finished surface. Note: 1. The Model XLO2 installation wrench for FP Recessed and SWC Concealed installations has a open side to accommodate the sprinkler deflector and can only be inserted in one way (see Figure 8). Care must be taken not to damage the deflector during installation. 2. Do not over -tighten sprinklers into fittings. It is recommended that Reliable dry sprinklers be installed using the wrench referenced in this bulletin. A pipe wrench may also be used to install dry sprinklers provided that it only engages the outer tube (steel pipe) of the assembly. Note that a pipe wrench will impart a large amount of torque into the final assembly. This torque will need to be matched or exceeded to remove the sprinkler at a later date. A leak free joint can normally be obtained by installing the sprinkler to a minimum torque of 22 ft-lb (30 N-m) after applying an appropriate thread sealant. 3. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling, and installation. Reliable installation wrenches are designed to install sprinklers while bulb protectors are in place. REMOVE THE PROTECTORS AT THE TIME THE SPRINKLER SYSTEM IS PLACED INTO SERVICE. Removal of the protectors before this time may leave the glass bulb vulnerable to damage. Remove protectors by undoing the clasp by hand. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. 4. Do not remove the wax fillet in the gap between the cup that supports the bulb and the wrenching boss. XLO2 Installation Procedure Step 1 Step 2 T Step 3 i Bulletin 016 January 2022 Page 9 of 10 www.reliablesprinkler.com F3R Wrench (Standard & HB trims) Maintenance Reliable Model DH56 series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non -operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. XL02 Wrench (FP recessed and SWC trims) Ordering Information Specify: Sprinkler Type • Model DH56 Dry Extended Coverage Horizontal Sidewall Sprinkler Trim Style • Standard Escutcheon • HB Escutcheon • FP Recessed Esctucheon • SWC Cover Plate Replace any sprinkler which has been painted (other than factory Temperature Rating applied). A stock of spare sprinklers should be maintained to 155°F (68°C) allow quick replacement of damaged or operated sprinklers. 175°F (79°C) Failure to properly maintain sprinklers may result in inadvertent 200°F (93°C) operation or non -operation during a fire event. Finish Guarantee See available combinations (depending on trim style) on pages 3-6 For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents US Patent No. 7,841,418 Length • "A" Dimension (face of fitting to finished wall surface, in 1/4" [6mm] increments) Installation Wrench • Model F3R (Standard & HB trims) • Model XL02 (FP Recessed & SWC trims) 00 0 M O ti 0) M Bulletin 016 January 2022 Page 10 of 10 www.reliablesprinkler.com :1 Bulletin 135 April 2021 Rel ® Model F1 Res Series Glass Bulb Residential Sprinklers cULus Listed Features • cULus Listed Residential Sprinklers • Available in pendent and horizontal sidewall orientations • Decorative finishes available, including recessed escutcheons and conical concealed cover plates Product Description Model F1 Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The F1 Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model F1 Res Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The Model F1 Res residential sprinklers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA 13D applications, the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this Bulletin. For NFPA 13 applications, Residential Sprinkler Summary Important Note: Model D wrench and Model GFR2 wrench are no longer compatible with this product. Model W2 (non - recessed) and Model W4 (recessed, concealed) are required. fi the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/ min), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model F1 Res Series sprinklers are listed for use in wet systems only. Sprinkler Model Sprinkler Identification Number (SIN) Orientation K-Factor gpm/psi112 (Ipm/bar'/2) Thread Size NPT or ISO7-1 Installation Options Max. Coverage Area ft x ft (m x m) F1 Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x16 (4.9 x 4.9) F1 Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1 Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1 Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1 Res30 CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed 14 x 14 (4.3 x 4.3) F1 Res49 CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed 20 x 20 (6.1 x 6.1) F1 Res58 CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed 20 x 20 (6.1 x 6.1) F1 Res76 CCP R7618 Pendent 7.6(109) 3/4 Conical Concealed 20 x 20 (6.1 x 6.1) F1 Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20 (4.9 x 6.1) F1 Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20 (4.9 x 6.1) F1 Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20 (4.9 x 6.1) F1 Res 58 HSWX RA3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 14 x 26 (4.3 x 7.9) Note: Please note SIN difference between F1 Res58 HSW (R3533) and F1 Res58 HSWX (RA3533). www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or ISO7-1 R1/2 Sensitivity Nominal K-Factor: 3.0 (43 metric) Fast -response Max. Working Pressure: 175 psi (12 bar) Temperature Ratings 155°F(68°C) Material Specifications 175°F (79°C) Thermal Sensor: 3 mm glass bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed" Sealing Assembly: Nickel Alloy with PTFE Sprinkler Wrenches Load Screw: Bronze Alloy Model W2 Deflector: Bronze Alloy Model W4 (Recessed) *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Ow Model F1 Res30 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) DIA. Face of fitting 1-15/16' to finished (49mm) DIA. ceiling 1/2" (13mm) Threads +/- 1/4" (6mm) Wrench Flat 'VH Sealing Assembly 2 1/4" MStll1 FOM 09 Glass Bulb (57mm) I 1-3/4" (44mm) +/- Load Screw 1/4" (6mm) Deflector 1-1/4" (32mm) 2 7/8" (72mm) DIA. Components Dimensions F2 & FV Recessed Escutcheon Installation Model F1 Res30 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems0) Maximum Coverage Area (2) ft. x ft.(m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 8 (30) 7.0 (0.48) 1 to 4 inches (25 to 100 mm) 14 x 14 (4.3 x 4.3) 10 (38) 11.0 (0.76) 15 x 15 (4.6 x 4.6) 12 (45) 16.0 (1.1) 16 x 16 (4.9 x 4.9) 13 (49) 18.8 (1.3) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliable Page 2 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or IS07-1R1/2 Sensitivity Nominal K-Factor: 4.9 (71 metric) Fast -response Max. Working Pressure: 175 psi (12 bar) Temperature Ratings 155°F (68°C) Material Specifications 175°F (79°C) % Thermal Sensor: 3 mm glass -bulb Recessed Escutcheons \ / Sprinkler Frame: Brass Alloy F1 Recessed Button: Copper Alloy F2 Recessed Sealing Assembly: Nickel Alloy with PTFE FV Recessed* _ Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model W4 (Recessed) *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1 Res49 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) 2-1/4" (57mm) DIA. Face of fitting DIA. Face of fitting 1-15/16" to finished 1-15/_ to finished (49mm) DIA. ceiling (49mm) DIA. ceiling 5/8" (16mm) 1/2" (13mm) +/- 3/8" (9mm) +/ 1/4" (6mm) fYJStltI 2-1/4" (57) 1-5/8" (41mm) +/- 1-3/4" (44mm) +/- 3/8" (9mm) 1/4" (6mm) 1-1/4" y I I (32mm) 2-7/8" (72mm) DIA. 2-7/8" (72mm) DIA. Dimensions F1 Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model F1 Res49 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area(') ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 13 (49) 7.0 (0.48) 1 to 4 inches (25 to 100 mm) 14 x 14 (4.3 x 4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9 x 4.9) 13 (49) 7.0 (0.48) 18 x 18 (5.5 x 5.5) 17 (64) 12.0 (0.83) 20 x 20 (6.1 x 6.1) 20 (76) 16.7 (1.15) 12 x 12 (3.7 x 3.7) 15 (57) 9.4 (0.65) 4 to 8 inches (100 to 200 mm) 14 x 14 (4.3 x 4.3) 16 (61) 10.7 (0.74) 16 x 16 (4.9 x 4.9) 17 (64) 12.0 (0.83) 18 x 18 (5.5 x 5.5) 19 (72) 15.0 (1.03) 20 x 20 (6.1 x 6.1) 22 (83) 20.2 (1.39) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliably Page 3 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or ISO7-1 R1/2 Sensitivity Nominal K-Factor: 5.8 (84 metric) Fast -response Max. Working Pressure: 175 psi (12 bar) Temperature Ratings 155°F (68°C) Material Specifications 175°F (79°C) Thermal Sensor: 3 mm glass bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy F1 Recessed Button: Copper Alloy F2 Recessed Sealing Assembly: Nickel Alloy with PTFE FV Recessed* Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model W4 (Recessed) *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1 Res58 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) 2-1/4" (57mm) DIA. Face of fitting V of fitting 1-15/16'. to finished inished 4 (49mm) DIA. ceiling eiling 5/8" (1 6mm)(13mm) +/ 3/8" (9mm)4" (6mm) O�Stl� 2-1/4" (57)44mm)1-5/8" (41mm) +/-" (6mm) 3/8" (9mm) 1-1/4" I (32mm) 2-7/8" (72mm) DIA. 2-7/8" (72mm) DIA. Dimensions F1 Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model F1 Res58 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems') Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16 (4.9 x 4.9) 16(61) 7.6(0.52) 1 to 4 inches (25 to 100 mm) 18 x 18 (5.5 x 5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1 x 6.1) 22 (83) 14.4 (1.0) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliable Page 4 of 15 April 2021 www.reliablesprinkler.com Finishes Technical Specifications (See Table N) Style: Pendent and Recessed Pendent Sensitivity Threads: 3/4" NPT or ISO7-1 R3/4 Fast -response Nominal K-Factor: 7.6 (109 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) Material Specifications 175°F (79°C) Recessed Escutcheons \ t Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy F1 Recessed F2 Recessed 1 Button: Copper Alloy FV Recessed* Sealing Assembly: Nickel Alloy with PTFE Sprinkler Wrenches' Load Screw: Bronze Alloy Model W2 Deflector: Bronze Alloy Model W4 (Recessed) *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1 Res76 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) 2-1/4" (57mm) DIA. Face of fitting4,(49 Face of fitting 1-15/16" to finished to finished (49mm) DIA. ceiling ceiling 5/8" (16mm)1/2" (13mm) +/- 3/8" (9mm)+/- 1/4" (6mm) 09StlH 2-1/4" (57)1-3/4" (44mm)1-5/8" (41mm) +/1/4" (6mm) 3/8" (9mm) 1-5/8" I (44mm) 2-7/8" (72mm) DIA. 2-7/8" (72mm) DIA. Dimensions F1 Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model F1 Res76 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area (2) Flow Pressure Deflector to ft. x ft. (m x m) gpm (1/min) psi (bar) Ceiling Distance 18 x 18 (5.5 x 5.5) 21 (80) 7.6 (0.52) 1 to 4 inches (25 to 100 mm) 20 x 20 (6.1 x 6.1) 23 (87) 9.2 (0.63) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliable Page 5 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPT or IS07-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast -response Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model W4 *Note: Model FP escutcheons and CCP cover plates are not listed for use in positively pressurized ceiling plenums. Model F1 Res30 CCP and FP Recessed Pendent Sprinkler Installation Dimensions 9_R/n'- tP,7 --. CCP Recessed Escutcheon Installation 2-5/8" (67mm) DIA. 2-5/16" (59mm)DIA. :ace of fitting to finished ceiling Face of fitting to finished ceiling -1/4" (32mm) 1-1/4" (32mm) / 1/4" (6mm) +/ 1/4" (6mm) 15/16"4mm 1" /4" (6m (24mm) +/- 1/4" (6mm) L3-3/16" (78mm) DIA. FP Recessed Escutcheon Installation Model F1 Res30 CCP Pendent & FP Recessed Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe SystemsM Maximum Coverage Area(z) Flow Pressure Deflector to Ceiling Distance ft. x ft. (m x m) gpm (1/min) psi (bar) 12 x 12 (3.7 x 3.7) 8 (30) 7.0 (0.48) 1/2 to 1 inch (13 to 25 mm) 14 x 14 (4.3 x 4.3) 11 (38) 13.4 (0.92) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Reliable Page 6 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPT or ISO7-1 131/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast -response Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model W4 *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model F1 Res49 CCP & FP Recessed Pendent Sprinkler Installation Dimensions 7_V/R-1 /R7mm1 CCP Recessed Escutcheon Installation 2-5/8" (67mm) DIA. 2-5/16" (59mm)DIA. ace of fitting to finished ceiling i Face of fitting to finished ceiling -1/4" (32mm) 1-1/4" (32mm) /- 1/4" (6mm) o , r, r_-- r,, ,T, +/- 1/4" (6mm) 15/16"4mm 1" /4" (6m (24mm) +/- 1/4" (6mm) L3-3/16" (78mm) DIA. - FP Recessed Escutcheon Installation Model F1 Res49 CCP Pendent and FP Recessed Pendent Hvdraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 14 x 14 (4.3 x 4.3) 13 (49) 7.0 (0.48) 1/2 to 1 inch (13 to 25 mm) 16 x 16 (4.9 x 4.9) 14 (53) 8.2 (0.57) 18 x 18 (5.5 x 5.5) 18 (68) 13.5 (0.93) 20 x 20 (6.1 x 6.1) 20 (76) 16.7 (1.15) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Reliable Page 7 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPT or IS07-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast -response Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model W4 *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model F1 Res58 CCP and FP Recessed Pendent Sprinkler Installation Dimensions 2-5/8" (67mm) 2-5/8" (67mm) DIA. DIA. CCP Recessed Escutcheon Installation 2-5/16" (59mm)DIA. ace of fitting to finished ceiling Face of fitting to finished ceiling -- 1/4" (32mm) () 1-1/4" (32mm) - 1/4" (6mm) �, T r,,,, T„ +/- 1/4" (6mm) 11" m) (24mm4mm) L \�V +/- 1/4/4"" (6mm) 3-3/16" (78mm) DIA. FP Recessed Escutcheon Installation Model F1 Res58 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria - Minimum Flow and Residual Pressure in Wet Pipe Systems(' Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16 (4.9 x 4.9) 16(61) 7.6(0.52) 112 to 1 inch (13 to 25 mm) 18 x 18 (5.5 x 5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1 x 6.1) 22 (83) 14.4 (1.0) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Reliable Page 8 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Finishes Style: Conical Concealed Pendent and (See Table N) Recessed Pendent Sensitivity Threads: 3/4" NPT or ISO7-1 R3/4 Fast -response Nominal K-Factor: 7.6 (109 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) Recessed Escutcheons/Cover Plates Material Specifications CCP Conical Concealed Plate 135°F (57°C)* Thermal Sensor: 3 mm glass bulb FP Recessed* Sprinkler Frame: Brass Alloy Sprinkler Wrenches Button: Copper Alloy Model W4 Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model F1 Res76 CCP and FP Recessed Pendent Sprinkler Installation Dimensions ace of fitting to finished ceiling -1/4" (32mm) i- 1/4" (6mm) 15/16" (24mm) CCP Recessed Escutcheon Installation FP Recessed Escutcheon Installation Model F1 Res76 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria 1 -ace of fitting to finished ceiling -1/4" (32mm) /- 1/4" (6mm) 1" (25mm) /- 1/4" (6mm) Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area (2) Flow Pressure Deflector to Ceiling Distance ft. x ft. (m x m) gpm (1/min) psi (bar) 16 x 16 (4.9 x 4.9) 21 (80) 7.6 (0.52) 1 inch 1/2 (13 to o 25 mm) 18 x 18 (5.5 x 5.5) 22 (83) 8.4 (0.58) 20 x 20 (6.1 x 6.1) 25 (95) 10.8 (0.75) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 ReliablE� Page 9 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2" NPT or ISO7-1 R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast -response Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model W4 (Recessed) Model F1 Res44 Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 1-5/8" (41mm) 2-7/16" (62mm) 5/16" (8mm) Dimensions 3/8" (10mm) +/- 1/4" (6mm) 2-1/4" 1-15/16" (57mm) (49mm) - - DIA. DIA. +/- 1/4" (6mm) Top of Deflector Down from _ Ceiling to be Either 4" to 6" (100 to 150 mm) or 6" to 12" (150 to 300 mm) Based on Hydraulic Calculations F2 & FV Recessed Escutcheon Installation Model F1 Res44 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe SystemsM Maximum Coverage Area(') ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 12 (45) 7.5 (0.52) 4 6 inches (100 to 150 mm) t 14 x 14 (4.3 x 4.3) 14 (53) 10.2 (0.70) 15 x 15 (4.6 x 4.6) 15 (57) 11.6 (0.80) 16 x 16 (4.9 x 4.9) 16 (61) 13.3 (0.92) 16 x 18 (4.9 x 5.5) 18(68) 16.8(1.16) 16 x 20 (4.9 x 6.1) 23 (87) 27.4 (1.89) 18 x 18 (5.5 x 5.5) 19 (72) 18.7 (1.29) 12 x 12 (3.7 x 3.7) 14 (53) 10.2 (0.7) 6 to 12 inches (150 to 300 mm) 14 x 14 (4.3 x 4.3) 16(61) 13.2(0.91) 15 x 15 (4.6 x 4.6) 16 (61) 13.2 (0.91) 16 x 16 (4.9 x 4.9) 17 (64) 15.0 (1.03) 16 x 18 (4.9 x 5.5) 20 (76) 20.7 (1.43) 16 x 20 (4.9 x 6.1) 23 (87) 27.4 (1.89) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliable Page 10 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Sidewall Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass -bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast -response Temperature Ratings 155°F (68°C) 1 175°F (79°C) (1) SWC Cover Plates SWC Conical Concealed Plate (2) SWC-2 (Slotted) Conical Concealed Plate(3) Sprinkler Wrenches _ Model W4 SWC-2 Note: (1) Not for installation where the maximum ceiling temperature exceeds 100°F due to cover plate temperature rating. (2) 135°F SWC Conical Concealed Plate for 155°F (68°C) sprinklers (3) 135°F SWC-2 (Slotted) Conical Concealed Plate for 175°F (79°C) sprinklers Model F1 Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler and Installation Dimensions 1" (25mm) 1" (25mm) +/- 1/4" (6mm) 1/4" (6mm) Face of fitting to finished wall 2-5/16" ------ Top of Deflector Down a_= y from Ceiling to be Either 3 5/16" ffR�1_ (67mm) (58mm) - - - 4" to 6" (100mm to (84mm) DIA. DIA. 150mm) or 6" to 12" DIA. 5/16" (150mm to 800mm) r�, (8mm) Based on Hydraulic - Calculations 1 5/8" (41 mm) Dimensions SWC & SWC-2 Concealed Cover Plate Installation Model F1 Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems('( Maximum Coverage Area (2) ft. x ft. (m x m) Ordinary Temperature Rating 155°F (68°C) Intermediate Temperature Rating 175°F (79°C) Deflector to Ceiling Distance Flow gpm (I/min) Pressure psi (bar) Flow gpm (I/min) Pressure psi (bar) 12 x 12 (3.7 x 3.7) 13 (49) 8.7 (0.60) 14 (53) 10.2 (0.7) 14 x 14 (4.3 x 4.3) 14 (53) 10.2 (0.7) 14 (53) 10.2 (0.7) 15 x 15 (4.6 x 4.6) 16 (61) 13.2 (0.91) - - - - 4 to 6 inches 16 x 16 (4.9 x 4.9) 17 (64) 15.0 (1.03) -- _ (100 to 150 mm) 16 x 18 (5.5 x 5.5) 19(72) 18.7(1.31) -- -- 16 x 20 (4.9 x 6.1) 23 (87) 27.4 (1.89) - - - - 12 x 12 (3.7 x 3.7) 14 (53) 10.2 (0.7) - - - - 14 x 14 (4.3 x 4.3) 15 (57) 11.7 (0.81) - - - - 15 x 15 (4.6 x 4.6) 17 (64) 15.0 (1.03) - - 6 to 12 inches (150 to 300 mm) 16 x 16 (4.9 x 4.9) 18 (68) 16.8 (1.16) -- -- 16 x 18 (4.9 x 5.5) 20 (76) 20.7 (1.43) -- -- Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliably Page 11 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Finishes Style: Sidewall and Recessed Sidewall (See Table N) Threads: 1/2" NPT or ISO7-1 R1/2 Sensitivity Nominal K-Factor: 5.8 (84 metric) Fast -response Max. Working Pressure: 175 psi (12 bar) Temperature Ratings 155°F (68°C) �A C Material Specifications Thermal Sensor: 3 mm glass bulb 175°F (79°C) Recessed Escutcheons Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed Sealing Assembly: Nickel Alloy with PTFE Sprinkler Wrenches Load Screw: Bronze Alloy Model W2 Deflector: Bronze Alloy Model W4 (Recessed) Model F1Res58 Residential Horizontal Sidewall Sprinkler Installation Dimensions 2-7/16" (62mm) 5/16" (8mm) Dimensions Face of fitting to finished wall 3/8" (10mm) +/- 1/4" (6mm) 2-1/4" 1-15/16" (57mm) (49mm) DIA. DIA. 1-5/8" (41mm) +/- 1/4" (6mm) F2 & FV Recessed Escutcheon Installation Model F1 Res58 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Top of Deflector Down from Ceiling to be Either 4" to 6" (100 to 150 mm) or 6" to 12" (150 to 300 mm) Based on Hydraulic Calculations Minimum Flow and Residual Pressure in Wet Pipe Systems') Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 16 (61) 7.6 (0.52) 4 to 6 inches (100 to 150 mm) 14 x 14 (4.3 x 4.3) 18 (68) 9.7 (0.66) 15 x 15 (4.6 x 4.6) 19 (72) 10.7 (0.74) 16 x 16 (4.9 x 4.9) 21 (80) 13.2 (0.91) 16 x 18 (4.9 x 5.5) 25 (95) 18.6 (1.28) 16 x 20 (4.9 x 6.1) 29 (110) 25.0 (1.72) 12 x 12 (3.7 x 3.7) 22 (83) 14.4 (1.0) 6 to 12 inches (150 to 300 mm) 14 x 14 (4.3 x 4.3) 22 (83) 14.4 (1.0) 15 x 15 (4.6 x 4.6) 24 (91) 17.1 (1.18) 16 x 16 (4.9 x 4.9) 26 (98) 20.1 (1.39) 16 x 18 (4.9 x 5.5) 31 (117) 28.6 (1.97) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. Please note SIN difference between F1 Res58 HSW (R3533) and F1 Res58 HSWX (RA3533). Bulletin 135 Reliably Page 12 of 15 April 2021 www.reliablesprinkler.com Finishes Technical Specifications (See Table N) Style: Sidewall and Recessed Sidewall Sensitivity Threads: 1/2" NPT or ISO7-1 R1/2 Fast -response Nominal K-Factor: 5.8 (84 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) 175°F (79°C) Material Specifications Recessed Escutcheons Thermal Sensor: 3 mm glass bulb F2 Recessed ( Sprinkler Frame: Brass Alloy FV Recessed ' I� Button: Copper Alloy Sprinkler Wrenches Sealing Assembly: Nickel Alloy with PTFE Model W2 Load Screw: Bronze Alloy Model W4 (Recessed) Deflector: Bronze Alloy Model F1 Res58 HSWX Residential Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 1-7/8" (48mm) 3/8" (10mm) +/ 1/4" (6mm) +/- 1/4" (6mm) 2-7/8" (73mm) IF/ 2-1/4" 1-15/16" Top of Deflector Down From (57mm) (49mm) - - -- Ceiling to be Either 4" to 6" DIA. DIA. (100 to 150 mm) or 6" to 12" (150 to 300 mm) Based on 5/16° Hydraulic Calculations (8mm) Dimensions F2 & FV Recessed Escutcheon Installation Model F1Res58 HSWX Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems') Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 18 x 20 (5.5 x 6.1) 30 (114) 26.8 (1.85) 4 to 6 inches (100 to 150 mm) 20 x 20 (6.1 x 6.1) 30 (114) 26.8 (1.85) 16 x 22 (4.9 x 6.7) 33 (125) 32.4 (2.23) 16 x 24 (4.9 x 7.3) 38 (144) 42.9 (2.96) 14 x 26 (4.3 x 7.9) 42 (160) 52.4 (3.63) 18 x 20 (5.5 x 6.1) 35 (133) 36.4 (2.51) 6 to 12 inches (150 to 300 mm) 16 x 22 (4.9 x 6.7) 38 (144) 42.9 (2.96) 16 x 24 (4.9 x 7.3) 42 (160) 52.4 (3.61) 14 x 26 (4.3 x 7.9) 46 (174) 62.9 (4.34) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. Please note SIN difference between F1 Res58 HSW (R3533) and F1 Res58 HSWX (RA3533). Bulletin 135 Reliable Page 13 of 15 April 2021 www.reliablesprinkler.com Finishes Standard Finishes Special Application Finishes Sprinkler 1 F1, F2. FV, FP(3), CCP, SWC Conical ) Sprinkler �'� F1, F2. FV, FP(3), CCP, SWC (Conical) Escutcheons Cover Plates (1) Escutcheons Cover Plates (1) Bronze Brass Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Satin Chrome Satin Chrome Satin Chrome White White White Paint Black Black Black Paint Polyester 2> Polyester Polyester (2) Polyester Custom Color Custom Color Custom Color Paint Polyester Polyester Electroless Nickel - - PTFE (2) - Notes: (1) Paint or any other coating applied over the factory finish will void all approvals and warranties. (2) cULus Listed Corrosion Resistant. (3) The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Installation Models F1 Res sprinklers are to be installed as shown in this bulletin. Model F1, F2, FV, and FP recessed escutcheons are the only recessed escutcheons to be used with Model F1 Res sprinklers. Not all F1 Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutcheon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1 Res sprinklers, use only the Model W2 sprinkler Wrench; for installing Models F1 Res Recessed Pendent, Sidewall, Conical Concealed Pendent (CCP), and Sidewall Concealed (SWC and SWC-2) sprinklers use only the Model W4 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Installation of F1 Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4" (57 mm) for F1 or F2 recessed escutcheons; or 2-5/8" (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC-2 cover plates. Install F1 Res HSW sprinklers with a ceiling to deflector distance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and "Top" marking must face the ceiling. A 'leak tight" sprinkler joint can be obtained with the following torque: • 1/2" NPT and ISO7-1 R1/2: 8-18 ft-Ibs (11 — 24 N-m) • 3/4" NPT and ISO7-1 R3/4: 14-20 ft-Ibs (19 — 27 N-m) Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Model W2 Model W4 Model W4 Wrench Installation Examole IF') The Model W4 wrench includes two sets of jaws. One set of jaws is equivalent to a Model GFR2 wrench and the other set of jaws is equivalent to a Model W1 wrench. Use the smallest of the two sets of jaws that will fit on the sprinkler's wrench flats. The Model W4 wrench is used in conjunction with the installer's nominal 1/2" square drive ratchet and nominal 5" (125mm) long extension (not provided) as shown in Figure 13. Bulletin 135 Reliable Page 14 of 15 April 2021 www.reliablesprinkler.com Maintenance Reliable Model F1 Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non -operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed CCP, SWC, and SWC-2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non -operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler • Model (See Table A) • Temperature Rating • Threads (NPT or IS07-1) • Finish (See Table N) Escutcheon or Cover Plate • Model • Finish (See Table N) Sprinkler Wrench • Model W2 (Pendent and HSW) • W4 (Recessed and Concealed) Note: Please note SIN difference between F1 Res58 HSW (R3533) and F1 Res58 HSWX (RA3533). Ln m N O ti M 0) Z d Bulletin 135 ReliablE� Page 15 of 15 April 2021 www.reliablesprinkler.com Bulletin 074 October 2022 Reliable Features • Standard coverage quick -response sprinklers • Upright, pendent, horizontal sidewall, and vertical sidewall deflectors • Low profile, compact design • Available in a wide variety of finishes Product Description Reliable Model F1 FR56 series sprinklers are quick -response standard spray automatic fire sprinklers utilizing a sensitive 3.0 mm glass bulb thermal element. Pendent and horizontal sidewall sprinklers may be installed exposed or surface mounted using escutcheons such as the Reliable Models B, C, or HB (reference Technical Bulletin 204). When installed recessed or concealed, the Model F1 FR56 series sprinklers are specifically listed with and may only be installed with listed Reliable escutcheons and cover plates. Refer to the technical information on the following pages for specific listings for recessed and concealed installations and refer to Figures 5 and 6 for dimensional information. When fitted with an approved water shield, these sprinklers may considered intermediate sprinklers for use in racks, below grated walkways, and other areas where intermediate level sprinklers are required. Table A provides a summary of the approvals and availability of specific Model F1 FIR series sprinkler configurations. Additional technical information for each sprinkler model is provided on the following pages. F1 FR Series Sprinklers Summary F1 FR56 Series Quick Response Sprinklers K-factor 5.6 (80) Model F1 FR56 Pendent Model F1 FR56 Upright Model F1 FR56 Vertical Sidewall Model F1 FR56 Horizontal Sidewall Note: Not all versions of the product are shown. Note: This bulletin may contain information on New and Legacy sprinklers that reflects a dimensional change only. Sprinkler Iden- tification Number (SIN), application, performance, and listings/ approval are not otherwise affected. Sprinklers with New frames will include the suffix "N" in the order. Sprinkler K-Factor gpm/psi"2 Max. Working Pressure Sprinkler Model (Ipm/bar'1Z) Orientation Listings & Approvals psi (bar) Identification Number (SIN) Upright cULus, FM, LPCB, VdS, 175 (12) RA1425 Intermediate Upright EC, WM 250 (17) (cULus only) Pendent cULus, FM, LPCB, VdS, 175 (12) RA1414 EC, WM 250 (17) (cULus only) Concealed Pendent cULus, VdS, EC, WM 175 (12) 250 (17) (cULus only) RA1414 F1FR56 5.6(80) Horizontal Sidewall cULus, FM 175 (12) 250 (17) (cULus only) RA1435 Vertical Sidewall cULus, FM, LPCB 175 (12) RA1485 www.reliablesprinkler.com Technical Specifications Style: Upright, Intermediate Upright Threads: 1/2" NPT or ISO 7-131/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F(93°C) 286°F (141°C) Guards & Shields (New Frames) Factory Water Shield (cULus, FM) F-1 Guard (cULus, FM) F-3 Guard with Shield (cULus, FM) Guards and Shields (Legacy Frames) Factory Water Shield C-1 Guard (FM) C-3 Guard with Shield (cULus, FM) D-1 Guard (cULus) D-3 Guard with Shield (cULus) Sprinkler Wrench Model W2 Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals cULus Listed FM Approved LPCB VdS EC WM Model F1 FR56 Upright Sprinkler Components and Dimensions Deflector Glass Bull (3 mm Wrench FIz Threads �d Screw F1FR_HALF _UPR_INT Cap/Seal Assem 3 1/4" [83mm] Shown with Optional Factory Installed Water Shield ( Intermediate Upright) mm] Bulletin 074 Reliable Page 2 of 9 October 2022 www.reliablesprinkler.com Technical Specifications Style: Pendent Recessed Pendent Concealed Pendent Threads: 1/2" NPT or ISO 7-131/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings0l, 135-F(57-C) 155-F(68-C) 175-F(79-C) 200-F(93-C) 286-F (141-C) Recessed Escutcheons Model F1 (cULus, LPCB, VdS, CE, WM) Model F2 (cULus, FM, LPCB, VdS, CE, WM) Model FP (cULus, VdS, CE, WM) Cover Plate Model CCP (cULus, VdS(�), CE(2)) Guards & Shields (New Frames)(3) F-1 Guard (FM) F-5 Guard/Shield Kit (FM) F-7 Guard (cULus) F-8 Guard/Shield Kit (cULus) S-1 Shield (cULus, FM) Guards & Shields (Legacy Frames)(3) C-1 Guard (FM) C-5 Guard/Shield Kit (FM) D-1 Guard (cULus, FM) D-4 Guard/Shield Kit (FM) D-5 Guard/Shield Kit (cULus, FM) S-1 Shield (cULus, FM) Sprinkler Wrenches Model W2 (pendent) Model W4 (recessed or concealed) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals(4) cULus Listed FM Approved LPCB VdS EC WM Notes: 1. 286T (141 °C) temperature rated sprinkler not listed for recessed or concealed use. 2. VdS and CE approval for CCP concealed use is for 155°C (68°C) sprinkler ONLY. 3. Not suitable for recessed or concealed pendent installations. 4. When used surface mounted or exposed. See Recessed Escutcheon and Cover Plate section for specific approvals when installed recessed or concealed. Model F1 FR56 Pendent Sprinkler Components and Dimensions Threads Wrench Flat Glass Bulb (3 mm) Deflector F1FR_HALF _PEND_INT Cap/Seal Assembly — Screw Note: Please refer to Figure 8 for recessed and concealed installation. 3 1/4" [83mm] Rim — 2 1/4" [57mm] 1" [25mm] Shown with Optional S-1 Water Shield (Ordered Separately) Bulletin 074 Reliably Page 3 of 9 October 2022 www.reliablesprinkler.com Technical Specifications Style: Horizontal Sidewall Recessed Horizontal Sidewall Threads: 1/2" NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings (1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Recessed Escutcheons(z) Model F1 (cULus) Model F2 (cULus, FM) Model FP (cULus) Guards & Shields (New Frames)(3) F-4 Guard (FM) F-7 Guard (cULus) Guards & Shields (Legacy Frames)(3) C1 Guard (FM) D1 Guard (cULus) Sprinkler Wrenches Model W2 (non -recessed) Model W4 (recessed) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals cULus Listed(4) FM Approved(5) Notes: 1. 286°F (141°C) temperature rated sprinkler not listed for recessed use. 2. FM approved recessed installation when used with Model F2 escutcheon ONLY. 3. Not suitable for recessed horizontal sidewall installations. 4. cULus Listed for Light and Ordinary Hazard when installed exposed or surface mounted. installed recessed. 5. FM Approved for Light Hazard ONLY. Model F1 FR56 Horizontal Sidewall Sprinkler Components and Dimensions Deflector Glass Bul (3 mn Wrench FI, -ad Screw Note: Please refer to Figure 9 for recessed installation. Frame F1FR_HALF _HSW Cap/Seal Assembly Threads i Listed for Light Hazard ONLY when 1 1/8" [28mm] mm] Bulletin 074 Reliable Page 4 of 9 October 2022 www.reliablesprinkler.com Technical Specifications Style: Upright Vertical Sidewall Pendent Vertical Sidewall Threads: 1/2" NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Guards & Shields (New Frames) F-2 Guard (FM) Guards & Shields (Legacy Frames) C1 Guard (FM) Sprinkler Wrenches Model W2 Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals') cULus Listed FM Approved LPCB(2) Notes: 1. Listed and approved for Light Hazard ONLY. 2. LPCB approved for use in pendent position ONLY. Model F1 FR56 Vertical Sprinkler Components and Dimensions Deflector Glass Bulb (3 mm) Wrench Flat Screw Frame F1FR_HALF_VSW Cap/Seal Assembly Threads 1 112" [38mm] 2 1/4" [57mm] Bulletin 074 Reliable Page 5 of 9 October 2022 www.reliablesprinkler.com Recessed and Concealed Installation: Pendent Sprinklers 2-1/4" 2-1/4" (57 mm) Dia. (57 mm) Dia. Hole in Ceiling Hole in Ceiling 1-15/16" 1-15/16" (49 mm) Dia. Reducing (49 mm) Dia. Reducing Fitting Fitting Face of Fitting Face of Fitting to Face of Ceiling to Face of Ceiling 1-1/8" (29 mm) at 7/8" (22 mm) at Max. Recess Max. Recess 3/8" (10 mm) at 3/8" (10 mm) at Min. Recess Min. Recess 03 1-3/4" 1-3/4" (44 mm) 1" (44 mm) 1-1/4" (25 mm) (32 mm) Minimum Maximum Minimum Maximum Recess 2-7/8" (72 mm) Dia. Recess Recess 2-7/8" (72 mm) Dia. Recess Models F1 & F1 FR Pendent Sprinkler Models F1 & F1 FR Pendent Sprinkler with Model F1 Recessed Escutcheon with Model F2 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment 1/2" (13mm) Nominal Adjustment Fi-REC_PEND-CCP 2-1/2" 2-1/2" (64 mm) Dia. (64 mm) Dia. Hole in Ceiling Hole in Ceiling 2-5/16" 2-5/16" (59 mm) Dia. Reducing (59 mm) Dia. Reducing Fitting Fitting Face of Fitting Face of Fitting Vented Cup to Face of Ceiling Vented Cup to Face of Ceiling 1-1/2" (38 mm) at 1-1/2" (38 mm) at Max. Recess Max. Recess 1" (25 mm) at 1" (25 mm) at Min. Recess Min. Recess r � (25 mm) 1/2" -L (12 mm) Minimum Recess 3-3/16" (78 mm) Dia. Maximum Recess Models F1 & F1 FR Pendent Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Note: Model FP recessed assemblies may not be used where the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. F1 Escutcheon (F2 Similar) w (25 mrn 1/2" (12 mm) Minimum Recess Maximum 3-5/16" (84 mm) Dia. Recess Model F1 FR56 CCP Conical Concealed Sprinkler 1/2" (13mm) Nominal Adjustment (Nominal Cover Plate Projection is 1" (25 mm)) Note: Model CCP concealed assemblies may not be used where the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model CCP cup are unobstructed following installation. FP Escutcheon CCP Cover Plate Bulletin 074 Reliable Page 6 of 9 October 2022 www.reliablesprinkler.com Recessed Installation: Horizontal Sidewall Sprinklers 1/2" (12 mm) Reducing +/- 3/8" (10 mm) 1-3/8" (35 mm) Maximum Recess Fitting Face of fitting to face of wall 1 4„ _ 12" (102 mm - 305 mm) Deflector to ceiling 2-1/4" 1-15/16" 2-7/8" (57 mm) (49 mm) - - - - (73 mm) Dia. Hole Dia. Dia. 1I — : 9/16 [14mm] F1 Recessed escutcheon 3/4" (19 mm) Adjustment 2 1/8" (54 mm) Minimum Recess Model F1 FR Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment F1FR_REc_Hsw 3/8" (16 mm) Reducing +/- 1/4" (6 mm) 1-5/8" (42 mm) Maximum Recess FittingNace of fitting o face of wall 1 4„ _ 12„ (102 mm - 305 mm) Deflector to ceiling 2-1/4" 1-15/16' 2-7/8" (57 mm) (49 mm) - - -- - (73 mm) Dia. DIA. Dia. Hole J9/16 [14mm] F2 Recessed escutcheon 1/2" (13 mm) Adjustment 2-1/8" (54 mm) Minimum Recess Model F1 FR Horizontal Sidewall Sprinkler with Model F2 Recessed Escutcheon 1/2" (13mm) Nominal Adjustment 1-1/4" (32 mm) Reducing +/- 1/4" (6 mm) Fitting Face of fitting 7/8" (22 mm) Maximum Recess to face of wall 1 4-1- 12" (102 mm - 305 mm) Deflector to ceiling 2-5/8" 2-5/16" 3-1/4" (67 (58 mm) - - - - (83 mm) Diaa Hole. Dia. Dia. 9/16 [14mm] �T Vented Cup 1-3/8" (35 mm) Minimum Recess Model F1 FR Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Note: Model FP recessed assemblies may not be used where the pressure in the space behind the sprinkler is positive with respect to the space in the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. Bulletin 074 ReliablE� Page 7 of 9 October 2022 www.reliablesprinkler.com Model W2 (upright, pendent) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed, similar but with zinc finish) Finishes') Model W4 (recessed, concealed pendent) Standard Finishes Special Application Finishes Sprinkler F1, F2 and FP(2) Escutcheons CCP Cover Plate(2) Sprinkler F1, F2 and FP(2) Escutcheons CCP Cover Plate(2) Bronze Brass Chrome Electroless Nickel PTFE(3)(4) Bright Brass Bright Brass Chrome Chrome White Paint Bright Brass(5) Satin Chrome Satin Chrome White Polyester(3) White Polyester Satin Chrome Custom Color Polyester Custom Color Paint Custom Color Pol est&3> Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Model FP escutcheons and Model CCP sprinklers utilize a galvanized steel cup with a finished trim ring or cover plate. 3. cULus Listed as corrosion resistant. 4. FM Approved as corrosion resistant. 5. For 200oF (93°C) maximum temperature rated sprinklers only. Installation Model F1 FIR Series sprinklers must be installed in accordance with NFPA13 and the requirements of all applicable authorities having jurisdiction. Model F1 FIR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in this Bulletin. Any other wrench may damage the sprinkler. The Models W2 and W4 wrenches have two sets of jaws. Use the smallest set of jaws that fit on the wrench flats of the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N•m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Glass bulb sprinklers have orange bulb protectors or protective caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Maintenance Reliable Model F1 FIR series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non -operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non -operation during a fire event. Bulletin 074 Reliable Page 8 of 9 October 2022 www.reliablesprinkler.com Guarantee For the guarantee, terms, and conditions, visit www. reliablesprinkler.com. Ordering Information Specify the following when ordering: Model F1FR56 Deflector/Orientation • Upright • Intermediate Upright • Pendent • CCP Concealed Pendent • Horizontal Sidewall • Vertical Sidewall Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table B Recessed Escutcheon(')(2) • F1 • F2 • FP Escutcheon Finish • See Table B CCP Cover Plate Temperature Rating • 135°F (57°C) [For use with 135°F (57°C) and 155°F (68°C) sprinklers.] • 165°F (74°C) [For use with 175°F (79°C) and 200°F (93°C) sprinklers.] CCP Cover Plate Finish • See Table B Sprinkler Wrench • Model W2 • Model W4 (recessed, concealed) • Model J (New frame with guard installed) • Model JD (Legacy frame with guard installed) Notes: 1. 286°F (141 °C) sprinklers are not listed to be used recessed or concealed. 2. For FM, recessed sprinklers must use the Model F2 escutcheon. co N Q0 0 rn rn rn M M L1 Bulletin 074 Reliable Page 9 of 9 October 2022 www.reliablesprinkler.com Miscellaneous PTFE THREAD SEAL TAPE (INDUSTRIAL) 1!1 4,itas=;� -For all industrial applications. -Made from 100% virgin PTFE. -No pigments, no additives. -Exceeds MILSpec T-27730A. 140 Meets MILSpec T-27730A -Temperature range of -450F to +550F. •VOC's (Volatile Organic Compounds): Minimal. 1.5% or less -May be used on all applicationsincluding water, oil, chemical, medical, and food processing where non -contamination standards are high. 60-10-260 1/2" x 260" STANDARD 0.4 DENSITY INDUSTRIAL GRADE 60-10-262 1/2" x 520" STANDARD 0.4 DENSITY INDUSTRIAL GRADE 60-10-264 1/2" x 1296" STANDARD 0.4 DENSITY INDUSTRIAL GRADE 60-10-262 3/4" x 260" STANDARD 0.4 DENSITY INDUSTRIAL GRADE 60-10-267 3/4" x 520" STANDARD 0.4 DENSITY INDUSTRIAL GRADE 60-10-269 3/4" x 1296" STANDARD 0.4 DENSITY INDUSTRIAL GRADE 60-10-270 1" x 260" STANDARD 0.4 DENSITY INDUSTRIAL GRADE 60-10-271 1" x 520" STANDARD 0.4 DENSITY INDUSTRIAL GRADE 60-10-272 1" x 1296" STANDARD 0.4 DENSITY INDUSTRIAL GRADE System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com ARGCO Updated 9/10/2018 0 ARGCO ARGCO... , aoo_asa_,o,s TUF-GLIDE Thread Sealant with PTFE Tuf-Glide® is the #1 selling PTFE paste in the fire sprinkler industry. It has replaced it's competitors as the pipefitters choice. APPLICATIONS: Tuf-Glide may be used on steel, aluminum, brass, copper, iron, reinforced fiberglass, CPVC, PVC and ABS threaded connections. Not for use with Stainless Steel Pipe. Tuf-Glide thread sealant is a non hardening, safe to use sealant containing PTFE for sealing and protecting threaded connections. Its low coefficient of friction allows tight makeup with low torque and breaks out easily without damaging threads. Tuf-Glide contains no lead or other harmful metals and is perfectly safe for use on potable water lines. Contains no silicone. NOT FOR USE ON OXYGEN LINES. Tuf-Glide is recommended for threaded pipe carrying: Acids, Dilute Helium Gases Air Hydraulic 011 Ammonia Inert Gases Aliphatic Solvents Kerosene Brine LP Gases CO2 Mineral Oils Caustic, Dilute Natural Gas Cold Tar Naphtha Nitrogen, Gaseous Cutting Oils Petroleum Solvents Fatty Acids Steam Heating Oils Vegetable Oils Freon Water Tuf-Glide is listed under the Uniform Plumbing Code (IAPMO), File No. 1282. Conforms to Federal Specification TT-S-1732 and the require- ments of British Standard 6920: Parts 1 & 2. TFW is recommended for Plumbing, HVAC, Industrial Piping, Chemical Processing Plants, Manufacturing Plants, Gas Utilities and Fire Sprinkler Piping. Meets U.S. Federal Specification TT-S-1732. VOC Content: Zero Grams per Liter ITEM # DESCRIPTION 1010005 1/2 PINT with BRUSHTOP 1010006 1 PINT with BRUSHTOP 1010007 1 QUART FLAT TOP 1010008 1 QUART with BRUSHTOP 1010009 1 GALLON PAIL 1010010 5 GALLON PAIL 1010011 55 GALLON DRUM FBC SYSTEM COMPATIBLE AR CO SINCE © 1981 THREAD SEALANT with PTFE C"e W lble with CPVC Pipe & Fitli'y' FBIC FBCTM System Compatible indicates that this product has been tested, and is monitored on an ongoing basis, to assure its chemical compatibility with FlowGuard Gold®, BlazeMaster@ and Corzan® piping systems and products made with TempRite@ Technology." "The FBC System Compatible Logo, FBCTM, FlowGuard Gold®, BlazeMaster@, Corzan@, and TempRite® are trademarks of Lubrizol Advanced Materials, Inc. or its affiliates. Service Rating: -350 F (-37° C) to 5000 F (2600 C) Pressures: to 10,000 psi for liquids, 2,000 psi for gases Shelf Life: Indefinite V.O.C. Content: None Fluid Type: Synthetic Color/Appearance: White Grainy Paste Dropping Point: (ASTM D-566) Not Applicable Specific Gravity: 1.20 Density (lb/gal): 10.0 Oil Separation: <5.0 WT. % LOSS @ 212°F (100°C) Flash Point: (ASTM D-92) >350°F (177°C) Nonvolatile Content: 100% Viscosity, Brookfield (ASTM D-2196) #7 Spindle, 5 rpm @ 77°F (25°C) 160,000-260,000 cps Brushable To: 0°F (-18°C) Copper Strip Corrosion: 1A (ASTM D-4048) System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com ARGCO Updated 1/3/2022 11 ARGOO.- aoo_as,_,a,s TUF-GLIDE Thread Sealant with PTFE APOR-M S© California Proposition 65 requirements are that any material produced after October 31st be labeled with the statement below. The only product considered hazardous in ARGCO TUF-GLIDE is Titanium dioxide which is still food grade allowable. Additionally titanium dioxide is only a respirable cancer substance when in a submicron size. Since it is encapsulated in a paste and greater than 1 micron particle size for the largest percentage it is debatable it even needs to be reported as there is no exposure mode. WARNING: This product can expose you to Titanium dioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov. Below is the formula chemical list for ARGCO TUFGLIDE with CAS Numbers. INGREDIENT CAS # Polybutenes 9003-29-6 Calcium sulfonate 61789-86-4 Potassium aluminum silicate 12001-26-2 Kaolin Clay 1332-58-7 Polyethylene 9002-88-4 Talc 14807-96-6 PTFE 9002-84-0 Titanium dioxide (1.2%) 13463-67-7 Organophyllic clay 68953-58-2 System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com ARGCO Updated 7/29/2020ARGCO.- 800-854_1015 Description ThreadFit° CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti -wear and anti -weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. Features • Heavy Duty Cutting Oil • Excellent Tool Life • Chlorine Free • All types of ferrous metal or pipe • Improved Surface Finish • Low Odor • Low Smoke SPEARS Spears® Compatible indicates that ThreadFit° CLEAR Thread Cutting Oil has been tested by Spears® Manufacturing to be compatible with Flameguaro'O pipe and fittings. FBC SYSTEM COMPATIBLE FBC'" System Compatible indicates that this product has been tested, and is monitored on an ongoing basis, to assure its chemical compatibility with FlowGuard Gold'', BlazeMaster° and CorzanO pipe and fittings. FBC'", FlowGuard Gold', BlazeMaster° and Corzan® are licensed trademarks of The Lubrizol Corporation or its affiliates. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 Installation ThreadFit° can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Nu © 2015 Fire Protection Products, Inc. FPPI°, ThreadFit° are registered trademarks of Fire Protection Products, Inc. LA MADE IN U.S.A. ThreadFit Thread C.ninq Oil Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See SDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources -Please recycle this container. See Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hotline. They may be reached at 1 800 424-9300. SPEARS° MANUFACTURING COMPANY SPERRS FS-5 = RED SPEARS ameG uard® CPVC FIRE SPRINKLER PRODUCTS TECHNICAL SPECIFICATIONS Low VOC CPVC Solvent Cement PRODUCT: Spears® F1ameGuard® FS-5 RED One -Step (no primer required) CPVC cement specifically formulated and approved for use with Spears® F1ameGuard® and other approved CPVC Fire Sprinkler Products with interference fit through 3". INTENDED USE: Spears® FS-5 is approved for use with Spears® F1ameGuard® and other approved CPVC Fire Sprinkler Products. See publication FG-3, F1ameGuard® Installation Instructions for additional application details. GENERAL PRODUCT SPECIFICATIONS: COLOR: RESIN: SPECIFIC GRAVITY: BROOKFIELD VISCOSITY RELATIVE SET: MAX VOC EMISSIONS: SHELF LIFE: Red CPVC 0.985 f 0.04 Heavy Body - Minimum 1600 cP@ 73 f 2°F (23°C +1 ° C) Fast 490 G/L per SCAQMD Rule 1168/316A 2 years from date stamped on the bottom of container. Note: Product usability is limited by the evaporation of the solvents when the container is opened and can cause the cement to thicken and reduce its usefulness. Always seal the can tightly between uses to prevent the solvent from becoming thickened, stringy or jelled. Do not add thinners to change viscosity of thickened cement. Significant changes in cement properties can result. CONFORMANCE STANDARDS AND APPROVALS: • NSF®/ANSI Standard 14 Listed and Certified for compliance to ASTM F493 • NSF®/ANSI Standards 14/61 Listed and Certified for Potable Water, Drain Waste and Vent, and Sewer service use (NSF®-PW, DWV, SW) NSF® Listed and Certified to requirements of the Uniform Plumbing Code (NSF® U.P. Code); NSF® Certified Lead -Free. • FM® and UL® approved for use with Spears®F1ameGuard® and other approved CPVC Fire Sprinkler Products. • Meets SCAQMD Rule 1168/316A for Compliance with LEED® (Leadership in Energy and Environmental Design). Low VOC product credit can be claimed for LEED Green Building Rating System - Indoor Environmental Quality. PACKAGING, SHIPPING & TRANSPORTATION INFORMATION: Can Size Standard Case OuantitX Pint 12 Quart 12 The following is general information for ground shipping, see SDS FS5-6 for additional detail. Proper Shipping Name: Adhesive Exceptions for Quantities < 1 liter Hazard Class: 3 Classification: Limited Quantity Identification Number: UN 1133 49CFR172.315 Marking: Packing Group: II <:> Label Required: Class 3 Flammable Liquid Note: Purchasers who may repackage this product must also conform to all local, state and federal labeling, safety and other regulations. SAFETY & USE PRECAUTIONS: WARNING: CAN CAUSE SERIOUS EYE IRRITATION. HARMFUL IF INHALED. MAY CAUSE DROWSINESS OR DIZZINESS. MAY CAUSE RESPIRATORY IRRITATION. REPEATED EXPOSURE MAY CAUSE SKIN DRYNESS OR CRACKING. KEEP OUT OF REACH OF CHILDREN. Do not take internally. Keep away from heat, spark, open flame, other sources of ignition. Vapors may ignite explosively. Use only in well ventilated area; if not well ventilated, use forced ventilation or NIOSH approved respirator. Avoid breathing vapors. Do not smoke, eat or drink while using. Avoid contact with skin and eyes. Use skin and eye protection. Eye contact may cause injury. Keep container closed when not in use. Contains Tetrahydrofuran (CAS#109-99-9); Methyl Ethyl Ketone (CAS# 78-93-3); Cyclohexanone (CAS# 108-94-1); Acetone (CAS# 67-64-1); CPVC Resin (CAS# 68648-82-8). FIRST AID Contact with eyes: Flush eyes immediately with plenty of water for 15 minutes and seek medical advice immediately. Skin contact: Remove contaminated clothing and shoes. Wash skin thoroughly with soap and water. If irritation develops, seek medical advice. Inhalation: Remove to fresh air. If breathing is stopped, give artificial respiration. If breathing is difficult, give oxygen. Seek medical advice. Ingestion: Rinse mouth with water. Give 1 or 2 glasses of water or milk to dilute. Do not induce vomiting. Seek medical advice immediately. INSTALLATION & INSTALLER TRAINING FS-5 is specialty cement; see Spears® publication FG-3, F1ameGuard® Installation Instructions, for specific details and limitations. Installation instructions are printed on the can label and instructional information is available on Spears®website at www.spearsmfg.com. Certified Installers Training for F1ameGuard® CPVC Fire Sprinkler Systems is also available. Contact Spears® for additional instructional information or formal training. AVOID USE AROUND DRY GRANULATED CALCIUM HYPOCHLORITE While CPVC Fire Sprinkler Systems typically are not disinfected, a fire or explosion may result if dry granular calcium hypochlorite is used to disinfect plastic piping systems that are exposed to organic vapors found in solvent cements, cleaners or primers when a water solution is not used. Calcium hypochlorite is a strong oxidizer and common in Pool & Spa chemicals such as "pool -shock". If required, it is recommended to purify lines by pumping nonvolatile chlorinated water into the piping system. Do not store or use dry granular calcium hypochlorite near solvent cements, cleaners and primers. Refer to Safety Data Sheet (SDS), Spears® publication FS5-6, for more information. LIMITED LIFETIME WARRANTY: Spears® Manufacturing Company warrants all new Solvent Cement and Primer products shall be free from defects in material and workmanship for the specified product shelf life based on the assigned manufactured date on the original product container. If any such product becomes defective under normal use and storage conditions during this warranty period, Spears® will replace the nonconforming solvent cement or primer product without charge. Spears® liability will be limited, without exception, to product replacement. Spears® further warrants properly made solvent cement joints using this product for the life of the system. See Spears® standard Limited Lifetime Warranty for additional detailed information and exclusions. Progressive Products From Spears® Innovation & Technology SPEARS® MANUFACTURING COMPANY • CORPORATE OFFICE `� rt n 15853 Olden St., Sylmar, CA 91342 • PO Box 9203, Sylmar, CA 91392 sv (818) 364-1611 • www.spearsmfg.com NTH P�,ow © Copyright 2013 Spears® Manufacturing Company. All Rights Reserved. Printed in the United States of America 10/13. FS-5TS-1013 MI`MI High-performance intumescent firestop sealant FS-ONE MAX Applications ■ For effectively sealing most common through penetrations in a variety of base materials ■ For use on concrete, masonry and drywall ■ Mixed and multiple penetrations ■ Metal pipe penetrations: copper, steel and EMT ■ Insulated metal pipe penetrations: steel and copper ■ Plastic pipe penetrations: closed or vented Advantages ■ US -produced: 'Buy American" compliant ■ One product for a variety of common through penetrations ■ Cost-effective, easy -to -use solution ■ Water -based and paintable ■ Industry -leading VOC results ■ Ethylene glycol -free FBe ��....��}} SYSTEM COMPATIBLE Ill En,s.Eauo Chemical Mold and mildew resistant resistant F M PSSIF� FILL, VOID OR CAVITY MATERIAL °y 6o FOR USE IN THROUGH -PENETRATION W ~� UFIRESTOP SYSTEMS C �S US aPvrsoveo '° SEE UL FIRE RESISTANCE DIRECTORY 66Y7 I ntertek Order Designation FS-ONE MAX 20oz foil (3 case + disp) FS-ONE MAX 10oz tube (1 case) FS-ONE MAX 5 gallon (18 pails) FS-ONE MAX 20oz foil (1 case) FS-ONE MAX 20oz foil (3 cases) FS-ONE MAX 20oz Foil -Pallet FS-ONE MAX 10 oz cartridge FS-ONE MAX 5 gallon pail Technical data Chemical basis Water -based acrylic dispersion Approx. Density 84.3 IbMs Color Red Application temperature range 41 - 104 °F Approx. cure time') 4 mm/3 days Temperature resistance range -4 to 212 °F Mold and mildew performance Class 0 (ASTM G21-96) Mold and mildew resistance Yes Surface burning characteristics UL 723 (ASTM E84) Flame spread: 0 Smoke development: 10 Tested in accordance with UL 1479, ASTM E814, ASTM E84, CAN/ ULC-S115, ASTM G21, ASTM E90 California State fire marshal approval CSFM Listing 4485-1200:0108 for FS-ONE MAX Intumescent Firestop Sealant Expansion ratio (unrestricted, up to) 1:5 1) at 75°F/24°C, 50% relative humidity Package Content Item number 1 x Foil pack dispenser manual CS 270-P1, 75x Firestop sealant FS-ONE MAX 20 oz foil 3530252 12x Firestop sealant FS-ONE MAX 10 oz cartridge 3530249 18x Firestop sealant FS-ONE MAX 5 gallon pail 3530263 25x Firestop sealant FS-ONE MAX 20 oz foil 3530250 75x Firestop sealant FS-ONE MAX 20 oz foil 3530251 600x FSONE-MAX 20 oz foil, 290x Bulk Shipping Condition 3534713 2101531 2101533 Hilti. Outperform. Outlast. U © Tulle Hilti, Inc. (USA) 1-800-879-8000 1 www.us.hilti.com I en espahol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca Product information CAST -IN FIRESTOP DEVICES (CP 680-P AND CP 680-M) For use in Dust and fiber free environments such as hospitals, computer centers and laboratories Concrete floor assemblies rated up to 4 hours Product description A one-step cast -in firestop device for a variety of pipe materials and diameters Helps reduce labor costs and increase productivity Ready -to -use out of the package Internationally tested and approved by UL and FM Reduces the chance of project delays due to failed inspections Product features Quick and simple installation SpeedLine Alignment system promotes faster layout QuickTurn System creates fast, simple vertical connections Integrated moisture and smoke seal Innovative adapter for metal deck applications Installation and applications Concrete floors from 2.5" (63 mm) thickness for either flat concrete or concrete over metal deck CP 680-M: - Insulated and non -insulated metal pipes - EMT and electrical conduits - Cable bundles - Multiple pipes CP 680-P: Addresses all applications for CP 680-M as well as the following: - Plastic pipes such as PVC, CPVC, ABS, ENT and FRPP - Fresh and waste water pipes Not suited for Areas with high condensation Outdoor areas Wall applications Installation and applications Notice Before handling, read Material Safety Data Sheet and product label for safe usage and health information. Instructions below are general guidelines — always refer to the applicable drawing in the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information Instructions for use Before pouring concrete, secure the cover cap in place, thereby preventing the flow of concrete into the cast -in device Do not use for wall applications CP 680-P in CP 680-M in CP 680-P over CP 680-M over concrete over concrete over metal deck metal deck wood forms wood forms Technical Data CP 680-P and CP 680-M ID Footprint Opening required thru metal deck 2" 3-3/4" x 4-1/2" 3-1/2" diameter 3" 4-3/4" x 5-5/8" 4-1/2" diameter 4" 6-3/8" x 6-3/4" 5-1/2" diameter 6" 9" x 9-1/2" 7-1/2" diameter Expansion temperature 392°F (200°C) Expansion rate Standard height Temperature resistance Color Tested in accordance with • LIL 1479 • ASTM E 814 Internationally tested and approved 1:50 (unrestrained) 1:30 (Load expansion, Load = 20g/cm3) 8" Maximum 212°F (100°C) CP 680-P: red CP 680-M: black • ASTM G21 • CAN/LILC-S115 QSSIF� FIRESTOP DEVICE 40� FOR USE IN THROUGH -PENETRATION U FIRESTOP SYSTEMS F M C 1 uc SEE UL FIRE RESISTANCE DIRECTORY J APPXOVEO FBCT System Compatible indicates that this product has been tested, and is monitored on anongoing basis, to assure its chemical compatibility with FlowGuard Gold@, BlazeMasterOO and CorzanOO piping systems and products made with TempRiteOO Technology." "The FBC System Compatible Logo, FBCT"', Flow - Guard Gold®, BlazeMasterOO, Corzan0, and TempRiteO are trademarks of Lubrizol Advanced Materials, Inc. or its affiliates." ,7 /Hilti Firestop Hilti, Inc. Saving lives 1-800-879-8000 1 en espanol 1-800-879-5000 through innovation www.hilti.com and education 91 Cl MI` Floor Device Standoff Component (for use with CP 680 P/M) Product description ■ Standoff component provides a pre- or post -poured solution for water containment and riser clamp support of vertical pipe penetrations. ■ Fully threaded coupler for use with height extensions and assembly of standoff component to CP 680 P/M. Product features ■ Standoff component may be installed before or after the concrete is poured ■ Post poured installation allows floor finisher to work without obstacles or risk of damaging pre -installed standoffs ■ Designed to meet requirements for a minimum 2" standoff above substrate surface ■ The completed application can provide an effective solution for fire protection, water containment and riser clamp support for vertical pipe penetrations' ■ Tested load values according to UL 203 Areas of application ■ Vertical pipe penetrations, metallic and non-metallic ■ Support of vertical pipe clamps for CP 680 P/M ■ Areas subject to flood or needing water containment Riser clamp support for CP 680 P/M only. Standoff component may be used with Hilt! Firestop Drop in device CFS-DID for standoff requirements and water containment. Standoff component is not intended for use with CFS-DID as a load bearing element. Installed CP 680 with coupler and CFS-DID lid. Installed CP 680 with standoff component Installed CP 680 with standoff component and CP 680 lid. Technical Data* Floor Device Standoff Component Dimensions (height) 2 inch diameter: 3.15" 3 inch diameter: 3.15" 4 inch diameter: 3.4" 6 inch diameter: 3.4" Installed height 2 inch diameter: 2.35" (height above coupler after 3 inch diameter: 2.16" threading) 4 inch diameter: 2.32" 6 inch diameter: 2.16" Minimum Slab Thickness 2 inch diameter: 4.5" slab 3 inch diameter: 5" slab 4 inch diameter: 5.5" slab 6 inch diameter: 5.6" slab Consistency Coupler: Polypropylene Standoff: Metal with plastic overlay Color Red Storage temperature 40 °F (5 °C) to 104 °F (40 °C) Curing time Non -curing Tested in accordance with ASTM G21 Load Values (maximum allowable)* per UL 203 2 inch 750 7 Metallic and non-metallic pipes 3 inch 1050 4 inch 1500 6 inch 2650 *Check local codes and requirements. Hilti Firestop Saving lives through innovation l and education Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.com • www.us.hilti.com/firestop • an espanol 1-800-879-5000 Hilti (Canada) Corporation 1-800-363-4458 www.hilti.ca • www.hilti.ca/firestop FIRE SPRINKLER SPARE HEAD BOXES -Heavy duty 20 gauge steel construction V -Red powder coated finish -Knockouts and shelf to accommodate any 1/2" or 3/4" sprinkler head -Shelf is positioned to allow for a typical sprinkler head wrench -All-welded construction and full length hinge -Slotted for easy mounting with screws, rivets or strapping (Not intended for exposed or harsh environments) 3 Head Box (6510152) 6 Head (6510151) 12 Head Box ,4"- (6510150) 6 Large Head Box (6510151A) zs• System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com ARGCO Updated 10/15/2020 0 ARGCO AAGCO- , aoo_as4_,o, a