APPROVED FIR2022-0135+Fire_Sprinkler_Plan+5.22.2023_7.23.46_AM+3558769RISER ROOM COMPONENTS LEGEND SPARE SPRINKLER STOCK SYMBOL LEGEND SCOPE OF WORK REDHAWK FIRE PROTECTION, LLC X # QTY SIZE DESCRIPTION MANUFACTURER MODEL / PART NO REQUIRED SIGNAGE QTY SIZE DESCRIPTION EXISTING SPRINKLER PIPING WITH LABEL 1 1 4 GROOVED FLEXIBLE COUPLING GENERIC N/A N/A 10 t/2 RELIABLE, F1Res49, R3516, 4.9K, 155°F, WHITE X 2 1 4 DOUBLE CHECK DETECTOR ASSEMBLY DERINGER D30 N/A 2 t/2 RELIABLE, F1 Res49, R3516, 4.9K, 175°F, WHITE NEW WET STEEL SPRINKLER PIPE WITH LABEL X-X 3 1 4 x 2 GROOVED CONCENTRIC REDUCER GENERIC N/A N/A 1 N/A RELIABLE SPRINKLER MODEL W4 WRENCH X 4 1 2 CPVC GROOVED ADAPTER GENERIC N/A N/A NEW WET CPVC SPRINKLER PIPE WITH LABEL 5 1 2 x 1'/4 WATERFLOW SWITCH POTTER VSR-M N/A / PIPE HANGER 6 1 1 TEST & DRAIN W/ t/2' PRESSURE RELIEF GLOBE UTD MAIN DRAIN (1) 7 1 t/2 PRESSURE GAUGE GENERIC N/A N/A Approved GROOVED RIGID COUPLING 8 1 4 GROOVED CHECK VALVE RELIABLE MODEL G N/A DFM Gkrlsgurt 9 1 12 CT SPARE SPRINKLER STOCK BOX (SEE SPARE STOCK LEGEND) ARGCO 6510150 N/A South County Fire GROOVED FLEXIBLE COUPLING NOTES: Date: 06/01 /2023 777�� 1. SIGNAGE TO BE PROVIDED ON ALL CONTROL VALVES, DRAIN VALVES, TEST CONNECTIONS, FIRE DEPARTMENT CONNECTIONS AND SUPERVISORY AIR LINES AND 06-01-2023 0W ROOM SEISMIC BRACE - LATERAL (PERPENDICULAR TO PIPE) PLAN REVIEW 0-11 1-7 INSTALLED AT LOCATIONS GIVEN PER NFPA 13 (2013) SECTION A6.10. APPROVED WITH CONDITIONS: 2. HYDRAULIC CALCULATION PLACARDS TO BE PROVIDED AND INSTALLED ON THE SYSTEM RISER PER NFPA 13 SECTION 25.5. 1. SEE SOUTH COUNTY FIRE SPRINKLER STANDARDS REGARDING SIGNAGE REQUIREMENTS. (SOUTHCOUNTYFIRE.ORG) ���' SEISMIC BRACE - LONGITUDINAL (PARALLEL TO PIPE) 2. AN ALL WEATHER MAP OF THE SPRINKLER SYSTEM REQUIRED INTHE RISER ROOM. 3. KNOX BOX REQUIRED AT RISER ROOM DOOR. (SOUTH COUNTY YY SEISMIC BRACE - LATERAL AND LONGITUDINAL SPRINKLER STANDARD) 4. ALL CONTROL VALVES REQUIRED TAMPER SWITCHES INCLUDING DOUBLE CHECK VALVE CONTROL VALVES. N — — — — — REMOTE AREA BOUNDARY 5. MEANS SHALL BE PROVIDED DOWNSTREAM OF BACKFLOW PREVENTION VALVES FOR FORWARD FLOW TESTS AT A MINIMUM FLOW RATE OF THE SYSTEM DEMAND. (NFPA 2013 6.8.8) • XX HYDRAULIC NODE 6. LOCKING KNOX FDC PLUG IS REQUIRED. (SOUTH COUNTY FIRE SPRINKLER STANDARD) 7. FDC STEM SHALL BE PAINTED RED WITH 4" WHITE ADDRESS OF THE ELEVATION TAG BUILDING THE FDC SERVES. er 8. FDC SHALL HAVE INFORMATION STATING "AUTO SPRINKLER". N N DFM BURT 2 ELECTRIC FIRE ALARM BELL FOCI, , y FIRE DEPARTMENT CONNECTION - REMOTE FP1 � FIRE HYDRANT 1 2 3 4 5 6 -0o- GATE VALVE ENLARGED RISER ROOM PLAN FM7 VAULT B0 6" V 2' 4' SCALE: 1 /2"=1 '-0" A BUILDING CROSS SECTION (LOOKING NORTH 0 2' 4' 8' 16' SCALE: 1 /8"=F-0" ol5�P 1200M 2 ■ N 9 M CABINET `V 0 c RHFP POINT OF m CONNECTION 0 FIRE RISER SECTION C0 6" V 2' 4' SCALE: 1 /2"=1 '-0" 5 4 2 33 rn : 8" DI WATER LINE 6" PRIVATE � • 55-2" DI CLASS 52 HYDRANT - D ■ 4' WATER SUPPLY (BY OTHERS) 4" x 2'/z" x 2'/2" (BY OTHERS) YARD FDC ■ (BY OTHERS) 2 3 (4 5 6 7 8 9 10 11 12 ■ 10" BELL MOUNTED TO BUILDING EXTERIOR : (ALL WIRING & INSTALL : 200' DI CLASS 52 4" FDC LINE TO BE BY OTHERS) ; t..........................................................................................................................................................................................................................� . U) A T BLDG C BLDG AN 5; i Wr UNDER SEPARATE PERN IT ■ : RHFP STARTING POINT ■ ■ ■ ■ B : ■ ■ w■ w. z■ z_■ J• J■ IZ'■ Q'■ ■ _F ■ . C ■ ■ 00 DO ■ BLDG D BLDG B UNDER SEPARATE PERMIT UNDER SEPARATE PERMIT ■ ■ .D D .M 5 16 18 19 20 22 /7�2.5 23 71C24 25 N � D ■ .. oDD ■ �i ■ 8' DI WATER LINE ■ ■ ■ ALL UNDERGROUND WORK TO BE DONE BY OTHERS 1 0-7 D v U ILL OI `a RISER DRAIN PIPED TO EXTERIOR ABBREVIATIONS ATR ALL -THREAD ROD BB BOTTOM OF BEAM CL CENTERLINE CTS CUT TO SUIT DIN PIPE DOWN DR DROP FDC FIRE DEPARTMENT CONNECTION FF (OR AFF) ABOVE FINISH FLOOR FOC FACE OF CONCRETE FOW FACE OF WALL GALV GALVANIZED GOL GROOVE-O-LET IFOW INSIDE FACE OF WALL MT MECHANICAL TEE O.C. ON CENTER PIV POST INDICATOR VALVE POL THREADED PIPE-O-LET RC REDUCING COUPLING RN RISER NIPPLE SP SPRIG SS STAINLESS STEEL THR THREAD TS TOP OF STEEL OR TO STRUCTURE TYP TYPICAL UNO UNLESS NOTED OTHERWISE UP PIPE UP UNDERGROUND NOTES 01 - ALL UNDERGROUND WORK BY OTHERS. CONTRACTOR TO BE STATE LICENSED AND CERTIFIED TO INSTALL UNDERGROUND PIPING PER WAC 212-80. 02 - PIPE TYPE AND CLASS TO MEET LOCAL JURISDICTION APPROVAL. 03 - ALL UNDERGROUND PIPING SHALL HAVE 3 FEET MINIMUM BURY DEPTH TO TOP OF PIPE. 04 - ALL UNDERGROUND PIPING SHALL BE UL LISTED AND/OR FM APPROVED FOR FIRE PROTECTION. 05 - ALL UNDERGROUND PIPING SHALL BE RESTRAINED IN ACCORDANCE WITH THE SPECIFICATIONS AND NFPA 24 (2014). 06 - ALL UNDERGROUND PIPING SHALL BE HYDROSTATICALLY TESTED AT NOT LESS THAN 200 PSI OR 50 PSI ABOVE STATIC PRESSURE IN EXCESS OF 150 PSI (WHICHEVER IS GREATER) FOR TWO HOURS IN ACCORDANCE WITH NFPA 24. 07 - ALL UNDERGROUND PIPING SHALL BE FLUSHED IN ACCORDANCE WITH NFPA 24. FLOW THE REQUIRED RATE UNTIL WATER IS CLEAR AS INDICATED BY NO COLLECTION OF FOREIGN MATERIAL IN BURLAP BAGS AT OUTLETS. 4" - 490 GPM 10" - 2,400 GPM 6" - 880 GPM 12" - 3,520 GPM 228th Si SW 228th St SW SITE Whirly6all I, Safeway 1 $ 238th St SW Burlington Q r � \LE -VILLAGE I I .' A I ' 2aath St SW ' RED HAWK FIRE PROTECTION, LLC. (RHFP) WILL PROVIDE (1) WET PIPE AUTOMATIC SPRINKLER SYSTEM TO PROTECT THE ENTIRE PROPOSED NEW BUILDING. RHFP WILL START WORK AT 4" THREADED CONNECTION 6" AFF IN RISER ROOM ON LEVEL 1. ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED BY OTHERS AT A MINIMUM 40°F TO PREVENT FREEZING. EXCLUSIONS PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES. CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES ALL UNDERGROUND WORK INCLUDING BUT NOT LIMITED TO: BACKFILL, SELECT FILL, BREAKING PATCHING, SAW CUTTING, LAWN REPAIR, LANDSCAPING, TREE REMOVAL, STERILIZATION, DEVELOPMENT FEES AND CITY CONNECTION. HEAT TRACING IF REQUIRED GENERAL NOTES 01 - SPRINKLER SYSTEM DESIGN PER NFPA #13R (2016), AND CITY OF EDMONDS (AHJ). 02 - ALL MATERIALS SHALL BE NEW AND UL AND/OR FM APPROVED. 03 - FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH NFPA #13 AND AUTHORITY HAVING JURISDICTION. 04 - IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGH OUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE, AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. 05 - FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF. 06 - ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING, OR PATCHING TO BE BY OTHERS. 07 - 1" - 2" CPVC PIPE TO BE SCHED 80 CPVC WITH GLUE -ON CPVC FITTINGS. 08 - TYPICAL CPVC HANGER TO BE CPVC TYPE LINO. BUILDING CODE ANALYSIS OCCUPANCY CLASSIFICATION AND USE: R-2 BUILDING CONSTRUCTION TYPE: V-B APPLICABLE CODE(S): IBC (2018), IFC (2015) APPLICABLE STANDARDS: NFPA 13R (2016) NUMBER OF STORIES: 3 ACTUAL BUILDING HEIGHT: 38'-3" BUILDING AREA IN SQUARE FEET: 10,315 FT FIRE SPRINKLERS: YES FIRE ALARM: YES SMOKE CONTROL SYSTEM: NO SITE CLASS: D SEISMIC DESIGN CATEGORY: D OCCUPANCY CATEGORY: II SS: 1.32 S1: 0.50 SIDS: 0.88 SD1: 0.50 WATER FLOW INFORMATION WATERFLOW INFORMATION HAS BEEN PROVIDED BY PACE ENGINEERING SERVICES. THE FOLLOWING INFORMATION OBTAINED FROM WATER FLOW MODEL RECEIVED 08/11/2022. STATIC PRESSURE: 65 PSI RESIDUAL PRESSURE: 20 PSI @ 1900 GPM MODELED HYDRANT LOCATION ON 236TH ST. DESIGN CRITERIA PER NFPA 13R (2016), CITY OF EDMONDS, AND PROJECT SPECIFICATION RESIDENTIAL WET SYSTEM RESIDENTIAL (NFPA 13R) 16' x 16' SPACING DESIGN DENSITY: 13 GPM @ 7 PSI / MOST DEMANDING 4 SPRINKLERS 228th St SW P J I - I Ballinger Park �- v 1 r 236th SI Nile Shrine Golf Course l Costco Wholesale Q z .\1 ' l H I L LW OO D Ballinger Commons I = - Apartment Homes f � 1 , Regal Cinelnr e Mountlake D ©t lyrojod Cemetery Z �)m 5,evc V�/Aaye 80VALLEY AVE NW, SUITE D PUYALLUP, WA 98371 PHONE: (253) 840-9900 FAX (800) 591-4382 WA CL# REDHAHF90I OP NICET Stamp ....... �.....................� WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Travis Clifton Kinne co ■ 0835-1021-C Level 0 ■ Red Hawk Fire Protection, LLC N i REDHAHF901QP o Exphres ■ Signature DEC 31. 23 1 i...... ...................... A Approvals Required CITY OF EDMONDS OWNER / ARCHITECT Revisions Contract With: KIRTLEY-GOLF ASSOCIATES LLC 2820 OAKES AVE B EVERETT, WA 98201 PM: JAMES SCHWARTZ Phone: (425) 231-8426 Email: JSchwartz@Kirtley-Cole.com Contract Name: HOUSING HOPE EDMONDS LUTHERAN 8215 236TH ST SW EDMONDS, WA 98026 Drawing Title GENERAL NOTES Key Plan RECEIVED May 22 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT F I R2022-0135 Date: April 27, 2023 Job Number: 70106 Designer: LAUREN MAIN Building Permit: Drawing No. FP1 OF 2 SITE PLAN - FOR REFERENCE ONLY 0 4' 8' 16' 32' SCALE: 1/1 6"= F-0" VICINITY MAP NOT TO SCALE 02 #905 REWS W/ BACKING NUTS REDHAWK FIRE PROTECTION, LLC CA CA5 CB CA5 C DESIGN NOTES ❑ EXTERNAL WATER SOURCE AND RISER LOCATION. ❑2 WALKWAY LOCATED ABOVE, FIRE PROTECTION REQUIRED BELOW. (TYP) OPIPE AND SPRINKLERS LAID OUT TO AVOID STRUCTURAL BEAMS, HVAC DUCTWORK, LIGHTING AND ANY OTHER OBSTACLES. (TYP) in CEILING LEGEND CEILING BUILT UP DIRECTLY TO TJIs, FINISH HEIGHT TO BE 8'-0" SPRINKLER LEGEND Symbol Manufacturer SIN Model K-Factor Type Size Response Finish Temperature Note Quantity Reliable R3516 F1 Res49 4.9 Pendent % Quick White 175 °F SEMI -RECESSED 7 Reliable RA1664 DH56 5.6 Sidewall 1/2 Quick Brass 155 OF DRY HEAD 8 O Reliable R3516 F1Res49 4.9 Pendent % Quick White 155 °F SEMI -RECESSED 125 Total =140 n5 ----------------------------------- -------------------, o�--------------------------------- ti o� ---------------------------- -� I I \ , - a23 MAINT�N�NC� b32 pl5�i? pM AbA-1310� / 213A a' o O • 2 2 • • t • N • • • • �� LL ao 00 A17A CIO / VA O 2• ,2 • ; APA-[3 26b/ 1P C102 2 AnA-6 21312/ 113A 003 2 300 • • - • • ,, �� • • _ • O o 33 N 8,O • 2 N N 2 • - 4 3 3 ` • OOC 0 0 o 0 o 0 0 i 3 i • P I � - . -� • „ T A 1 CNZOOM � E-H • • FP1 I I I �AUNbpY 8 _ C121 LLLI I I L------ I ----------------------� --------------- I I------- -------------------- I -- ` Hydraulic Information Remote Area C OCCUPANCY CLASSIFICATION Residential 13R DENSITY (gp11111 0.10 for 432.04 ft2 (Actual 432.04 ft2) TOTAL HOSE STREAMS 100.00 TOTAL HEADS FLOWING 4 K-FACTOR 4.9 TOTAL WATER REQUIRED 155.64 TOTAL PRESSURE REQUIRED 29.556 BASE of RISER (gpm) 155.64 BASE of RISER (psi) 29.556 SAFETY MARGIN (psi) +35.004 (54.2%) FIG. 187 HANGER CPVC PIPE (1" - 2" ONLY) FIG. 187 HANGER UNHEATED AREA INSULATION FIRE SPRINKLER PIPING TJI JOISTS INSULATION AIR GAP REQUIRED TENTING PIPE AROUND ALL WET (BY OTHERS) SPRINKLER PIPING HEATED AREA AFCON FIG 187 TO WOOD JOIST CPVC / STEEL HANGER N.T.S FIG. 188 HANGER CPVC PIPE (1" - 2" ONLY) (2) #905 SCREWS W/ BACKING NUTS FIG. 188 HANGER TJI JOISTS AFCON FIG 188 TO WOOD JOIST CPVC / STEEL HANGER N.T.S PIPE TENTING (BY OTHERS N.T.S TOLCO FIG 29 TO WOOD JOIST CPVC / STEEL HANGER FIRE SPRINKLER PLAN -FIRST FLOOR 0 2' 4_ 8' 16' SCALE: 1 /8"=1'-0" n2 n3 n4 n5 n6 11011101- o� - tio 3 CZO��A7 �� 2CCn/ 1113A F LL C201 a' a co ❑ 213n/ 113A 26n/ IPA IF • 2 2 C203 2 2 C202 2 00 2 • • • 302 I LL • 3 • • • = • • '- • • • •JIL • 3 • 3 3 •� � ' UZ 0 E • • I I A A rt 11 FP1 I , ❑ 2 ❑ C C N.T.S Quo ❑/O A 2�n 3A LL s o • 2 2 a -0 2 2<c❑13A 2 2 23❑2A 2 303 304 306 • • 70 \` ice. • • - • O o mom 3 • • 3 ❑ � � 3 i • ' 305 351 307 _ � e • • ❑ , 353 LLJ 00 A FP1 • • • • 352 354 Moo FIRE SPRINKLER PLAN - SECOND FLOOR FIRE SPRINKLER PLAN - THIRD FLOOR 0 2' 4' 8' 16' 0 2' 4' 8' 16' SCALE: 1 /8"=1'-0" SCALE: 1 /8"=l'-0" 801 VALLEY AVE NW, SUITED PUYALLUP, WA 98371 PHONE: (253) 840-9900 FAX (800) 591-4382 WA CL# REDHAHF901 OP NICET Stamp ...........................-� WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Travis Clifton Kinne N 0835-1021-C Level CD Red Hawk Fire Protection, LLC 00 i REDHAHF901QP a- I Slynaturr jI �....................... =Mond Approvals Required CITY OF EDMONDS OWNER/ARCHITECT Revisions Contract With: KIRTLEY-COLE ASSOCIATES LLC 2820 OAKES AVE B EVERETT, WA 98201 PM: JAMES SCHWARTZ Phone: (425) 231-8426 Email: JSchwartz@Kirtley-Cole.com Contract Name: HOUSING HOPE EDMONDS LUTHERAN 8215 236TH ST SW EDMONDS, WA 98026 Drawing Title FIRE SPRINKLER PLANS Key Plan RECEIVED May 22 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT F I R2022-0135 Date: April 27, 2023 Job Number: 70106 Designer: LAUREN MAIN Building Permit: Drawing No. FP2 OF 2