APPROVED FIR2024-0090+Fire_Alarm_Plan+9.24.2024_6.58.58_AM+4518672REDHAWK FIRE PROTECTION, LLC WOODWAY HIGH SCHOOL PORTABLE P3 EDMONDS SD FIRE ALARM SYSTEM 7600 212TH ST. SW, EDMONDS, WA 98020 SYMBOL LEGEND SYMBOL QTY DESCRIPTION MOUNTING REQUIREMENTS SUPPLIER PART NUMBER CONVENTIONAL FIRE ALARM PANEL PART INCLUDES ENCLOSURE; MOUNT AT 72" TO TOP FACP - SIMPLEX 4001 SERIES EX PHOTO SMOKE DETECTOR 4 SQUARE DEEP w/ 3" ROUND RING s 1 SIMPLEX 4098-9714 MANUAL PULL STATION 4 SQUARE DEEP w/ 1 GANG RING; MOUNTED AT 48" TO TOP � 2 SIMPLEX 2099-9754 120VAC VOLTAGE PROTECTOR for CONTROL PANELS MOUNTS IN 1/2" OR 3/4" CABINET KNOCKOUT ® 1 w/ LOCKOUT & LABELS SPACEAGE E120V-GT 24VDC SURGE SUPPRESSOR; 2PR, 14-30VDC, 16-22AWG 4 SQUARE DEEP ss 1 DITEK DTK-2MHLP24FWB REMOTE NAC POWER SUPPLY w/ ONBOARD FCM-1 PART INCLUDE BACKBOX; SURFACE MOUNT APs 1 6.OA, 5- 3.OA NAC & 1- 0.5A AUX POWER HONEYWELL HPF-PS6 w/ FCM-1 1 WALL HORN w/ STROBE: WHITE 4 SQUARE DEEP; MOUNTED AT 80" TO BOTTOM SYSTEM SENSOR P2WL L'J SEE DEVICE DESIGNATION FOR STROBE cd SETTING V 1 WALL HORN w/ STROBE: WHITE: WEATHERPROOF SA-WBB BACK BOX: SURFACE MOUNT AT 80" TO BOTTOM SYSTEM SENSOR P2WK [i] SEE DEVICE DESIGNATION FOR STROBE cd SETTING NOTES: 1- DEVICE SUBSCRIPT: NW=NEW RR=REMOVE & RELOCATE EX=EXISITNG TO REMAIN AC=ABOVE CEILING RB=RELAY BASE WP=WATERPROOF WG=WIRE GUARD ISO=ISO BASE 2- CABLEING SHOWN IS FOR CIRCUIT REFERENCE ONLY AND DOES NOT INTENDED TO INDICATE THE EXACT PATHWAY. 3- DEVICES SHOWN ON DRAWINGS IN GRAY SCALE ARE EXISTING DEVICES AND MAY NOT BE INCLUDED IN THIS SYMBOL LEGEND UNLESS NOTED. 4- HORN/STROBE DECIBLE SETTING TO BE DETERMINED ON SITE, UNLESS OTHERWISE NOTED ON THE DRAWINGS. CAN BE FIELD ADJUSTED AT REQUEST OF AHJ. 5- ALL DEVICES WITH A WP SUBSCRIPT WILL REQUIRE THE USE OF A OUTDOOR OR WP BACKBOX. WIRE LEGEND SYMBOL DESCRIPTION THHN FPL FPLP WET COLOR CODING CIRCUIT TYPE NOTES A 1 PAIR 18AWG FIRE RATED CABLE YES 970 D60980 AQ293 CONVENTIONAL (IDC) CIRCUIT C 1 PAIR 14AWG FIRE RATED CABLE YES 972 60993B AQ226 AUDIBLE (NAC) CIRCUIT NOTES: ** DIFFERENT COLORS/STRIPE COMBINATIONS TO BE USED FOR DIFFERENT CIRCUIT TYPES. LABEL ALL CIRCUITS ACCORDINGLY 1- WIRE MANUFACTURER IS FOR REFERENCE PURPOSE ONLY. WHEN USING OTHER MANUFACTURE, ENSURE PROPER CROSS REFERENCE 2- FPLP CAN BE USED IN MOST ALL APPLICATIONS WITH THE EXCLUSION OF WET AND CIRCUIT INTEGRITY REQUIREMENTS 3- INSTALL WIRING PER NEC. USE CABLE TYPE CONSISTENT WITH NEC REQUIREMENTS, IE: PLENUM, RISER, UNDERGROUND, ETC. 4- THE "Y" FIBER OPTIC CABLE LISTED IS A BELDEN CABLE PART NUMBER AS WEST PENN NO LONGER SUPPORTS FIBER OPTIC CABLE 5- THIS CABLE MUST BE INSTALLED IN A CONTINUOUS PATH POINT-TO-POINT. ABSOLUTLEY NO SPLICES ARE ALLOWED. 6- THIS IS A SPECIFIC CABLE, NO ALTERNATES ARE ALLOWED =LAGNOTES NOTE # DESCRIPTION 25 PROVIDE HINGED PLASTIC COVER FOR FIRE ALARM MANUAL PULL STATION (TYP.) NAC Circuit Load, Voltage Drop & Battery Load Calculations APS-1 A APS Name: APS-1A Location: NEXT TO FACP IN STADIUM P.S. Type: HPF-PS6 Part#: Description: Standby: Alarm: P4 Output #1 NAC Sync N1A Output #2 Output #3 NAC Sync NAC Sync X-X X-X Output #4 Not Used X-X Output #5 Not Used X-X Output #6 Output #7 Not Used Not Used X-X X-X Aux Power X-X Total Qty 0.1390 0.1570 P2WL (135) Wall Horn w/ Strobe set at 135cd 0.0000 0.1960 1 1 P2WK (75) Wall Horn w/ Strobe set at 75cd, WP 0.0000 0.1760 1 1 # Devices per Circuit: Total Standby Circuit Calculated Amps (3): Total Alarm Circuit Calculated Amps (1): Wire Gauge Used (awg): Circuit Length (ft): Estimated Voltage Drop (dc): Estimated EOL Voltage (dc): Calculated Voltage Drop %: 2 0.000 0.372 14AWG 100 0.19 23.81 1 0.8% 0 0 0 0 0 0 0 2 0.000 0.000 0.000 0.000 0.000 0.000 0.0000 0.1390 0.000 0.000 0.000 0.000 0.000 0.000 0.0000 0.1570 14AWG 14AWG 14AWG 14AWG 14AWG 14AWG 0 0.00 24.00 14AWG 0 0.00 24.00 Total Amps Required 0.372 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 24.00 24.00 24.00 24.00 24.00 1 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 1) Current Draw Measurement based on: UL1971, 16-33V, DC, High db & Temporal Patten 2) Some Outdoor/WP Devices have the same Measured Current Draw as the Indoor Devices and may not listed separately above. 3) When the APS is configured for "Doors", Output #4 shutsdown on loss of AC Power. Therefore no "Standby" Current Draw is shown BATTERY LOAD CALC for APS-1 A: NAC P.S. Max Rating: 6.000 Hours Standby: 24 Total Standby Current: 0.1390 Minutes Alarm: 5 Total Alarm Current: 0.5290 Backup Generator? No Voice Evacuation? No Spare Circuit Capacity: 20% Military? No Spare Battery Load Factor: 25% MAXIMUM CHARGER CAPACITY IS: 33AH Total Amps Required: 0.372 % Used: Total Hours Required for Standby (AH): Total Hours Required for Alarm (AH): Minimum Battery Size Needed (AH): Spare Battery Capacity Required: Actual Battery Size Required (AH): Total AH Rated Batteries Supplied: = 6% 3.34 0.04 3.38 0.85 4.23 7.0 I T I I SYMBOL & WIRE STYLE IDENTIFICATION -Box 2C,D WIREXABLE INDENTIFIER 2C = 2 TYPE "C" CABLES D =1 TYPE "D" CABLE oPE Rac�EW CABLE INSTALLATION TYPES V7 S- ��- � �"� -S DEMO OR REMOVE EQUIPMENT FROM SERVICE S- 2HR- -2HR -S RACEWAY REQUIRED TO BE INSTALLED UTILIZING 1 of 3 NEC APPROVED 2HR METHODS OF PROTECTION --S AC POWER (120, 240 or 480VAC) --]-ENLARGED VIEW BOUNDRY i XTOP LINE INDICATES THE DETAIL # XX ' BOTTOM LINE INDICATES THE SHEET # XX END of LINE RESISTOR ELEVATION DETAIL CEILING INFO FLAG NOTE SHEET NOTE EQUIPMENT NOTE - - - _ _ ADA ROOM, AREA OR ZONE BOUNDRIES - - - - 2HR RATED WALL 1HR RATED WALL A EXISTING STADIUM FULL HEIGHT WALL PARTIAL HEIGHT WALL A,C C -CD C�- A EX APS FACP 120VAC DEDICATED MOUNT NEW APS NEXT TO EXISTING FACP IN STADIUM CUSTODIAN ROOM PORTABLE FIRE ALARM LAYOUT SCALE:1/8" = 1'-0" INSTALLATION & GENERAL WIRING NOTES: GENERAL NOTES: 1. INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE AHJ's, NEC AND CONTRACT DRAWINGS 2. WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT ROUTING. 2.1. WIRING SHOWN GOING "THRU" A DEVICE DOES NOT NEED TO TERMINATE AT THAT DEVICE IF DEVICE IS NOT ON THAT CIRCUIT. 2.1.1. MEANING VOICE, STROBE/NAC CIRCUITS DO NOT NEED TO PASS THRU SLC DEVICES & SLC CIRCUITS DO NOT NEED TO PASS THRU NOTIFICATION DEVICES. POWER CIRCUITS ONLY NEED TO GO FROM POWERED DEVICE TO POWERED DEVICE. 3. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. 4. VERIFY ALL LOCATIONS OF DEVICES WITH ELECTRICAL/ARCHITECTURAL PLANS. SCALE AND PLACE ALL DEVICES PER ELECTRICAL/ARCHITECTURAL PLANS. 5. ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS, SHORTS, GROUNDS AND PROPER "END -OF -LINE" RESISTANCE. EACH CIRCUITS METER READING MUST BE DOCUMENTED AND PRESENTED TO RED HAWK FIRE PROTECTION FIELD TECHNICIAN UPON ARRIVAL ONSITE FOR STARTUP & CHECKOUT. 6. AS-BUILTS: 6.1. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY RED HAWK FIRE PROTECTION TECHNICIAN. 6.2. AS-BUILTS SHALL BE KEPT ORDERLY AND BE CLEARLY MARKED WITH DIFFERENT COLOR PENS FOR EACH CIRCUIT AND/OR CIRCUIT TYPE. AS-BUILTS MUST INDICATE CHANGES TO THE FINAL DEVICE INSTALLED LOCATIONS IF NOT INSTALLED AT LOCATION SHOWN ON DESIGN DOCUMENTS. 6.3. AS -BUILT REDLINES NOT PROVIDING THIS INFORMATION WILL BE RETURNED TO THE INSTALLATION CONTRACTOR FOR CORRECTION. RED HAWK FIRE PROTECTION IS NOT RESPONSIBLE FOR THESE DELAYS. 7. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WITH RED HAWK FIRE PROTECTION PROJECT MANAGER. 8. ALL RED HAWK FIRE PROTECTION FIELD SERVICES MUST BE SCHEDULED WITH RED HAWK FIRE PROTECTION PROJECT MANAGER WITH A MINIMUM OF 14 WORKING DAYS ADVANCE NOTICE. 9. DO NOT INSTALL LINE VOLTAGE IN SAME CONDUIT AS POWER LIMITED CABLES. FIRE ALARM SPECIFIC NOTES: 1. SMOKE DETECTORS SHALL NOT BE INSTALLED WITHIN 36" OF ANY AIR DIFFUSER. 2. 2019 NFPA 72-17.7.1.12.3 REQUIRES THAT SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER FINAL CONSTRUCTION CLEAN-UP. 2.1. ANY SMOKE DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO CLEAN-UP MUST BE CLEANED OR REPLACED AND WILL BE INVOICED ON A T&M BASIS. 3. WALL MOUNTED NOTIFICATION DEVICES BACKBOX BETWEEN A MINIMUM OF 80" AFF TO A MAXIMUM OF 96" AFF. 3.1. DEVICES THAT ARE UNABLE TO BE MOUNTED WITHIN THAT RANGE MUST BE VERIFIED BY RED HAWK FIRE PROTECTION PRIOR TO INSTALLATION. 3.2. SEE FLOOR PLANS FOR CANDELA RATING OF EACH DEVICE INSTALLED. 4. ALL MANUAL PULL STATIONS ARE TO BE MOUNTED AT A HEIGHT NO GREATER THAN 48" TO TOP AND NO LOWER THAN 36" TO BOTTOM (PER ADA REQUIREMENTS). 5. FIELD VERIFY ALL SPRINKLER MONITORING DEVICES WITH FIRE PROTECTION CONTRACTOR 6. FIELD VERIFY ALL HVAC, FAN CONTROL, FIRE/SMOKE DAMPERS AND DUCT DETECTORS LOCATIONS WITH MECHANICAL CONTRACTOR 7. FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF RED HAWK FIRE PROTECTION TECHNICIANS. 8. NO TAPPING OF SIGNALING OR INITIATING ZONE CIRCUITS ARE ALLOWED. T-TAPPING OF STYLE 4 ADDRESSABLE CIRCUITS IS ALLOWED PROVIDING A SPLICE IS PROFESSIONALLY INSTALLED, POLARITY IS OBSERVED AND SHIELDS ARE CONTINUOUS AND FREE OF GROUNDS. SHIELDS MUST BE TERMINATED AT FACP ONLY. 8.1. CABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY JUNCTION BETWEEN THE FACP AND THE LAST DEVICE ON EACH CABLE RUN. SHIELDS AND OTHER FIRE ALARM CONDUCTORS (EXCEPT POWER GROUNDS) SHALL BE INSULATED AND COMPLETELY FREE FROM CONDUIT OR EARTH GROUNDS. SHIELDS WILL BE TIES TO GROUND ONLY AT THE FACP BY THE RED HAWK FIRE PROTECTION FIELD TECHNICIAN. 9. THE SYSTEM SHALL BE MONITORED BY A U.L. LISTED MONITORING STATION BEFORE AHJ TEST. 10. AS-BUILTS ARE REQUIRED AT TIME OF AHJ ACCEPTANCE. RED HAWK FIRE PROTECTION REQUIRED ELECTRICAL RED LINES WITHIN 2 WEEKS PRIOR TO AHJ TESTS. 10.1. EACH CIRCUIT (SLC, NAC OR POWER) MUST BE CLEARLY IDENTIFIED WITH A DISTINCT COLOR 10.2. EACH NAC CIRCUIT MUST BE CLEARLY MARKED AS TO WHICH DEVICES ARE ON EACH CIRCUIT AND IN THE ORDER THE DEVICES ARE WIRED TO COMPLETE THE CIRCUIT. FIRE ALARM - SEQUENCE OF OPERATIONS PANEL OUTPUTS o Cn m 0 Of� >, I_-cv o cn 06 co o � U_ c W N Q N C N W F a Alarm From � 0 0 0.0.0 E Area Smoke or Heat Detector X X X X Manual Station X X X X NOTES: X = ACTIVATE PROJECT CONTACT INFORMATION: CUSTOMER: NAME: SCOTT'S ELECTRIC SERVICE, LLC ADDRESS: 23811 STATE ROUTE 2 MONROE, WA 98272 CONTACT: BRIAN FURRIER PHONE: 206-679-3613 FAX: EMAIL: Brian@scottselectricservice.com FIRE ALARM / LIFE SAFETY PROVIDER: NAME: RED HAWK FIRE PROTECTION ADDRESS: 917 134TH AVE SW SUITE B-3 EVERETT, WA 98204 PHONE: 425-818-3313 FAX: SALESMAN: JEREMY MUNSON JeremyM@redhawkfp.com EXT: PM: JAMES PAN JamesP@redhawkfp.com EXT: DESIGNER: SEAN FODOR SeanF@redhawkfp.com EXT: SCOPE OF WORK & DESIGN BASIS FIRE ALARM SYSTEM INSTALL IN NEWLY ADDED PORTABLE BUILDING. NEW POWER SUPPLY, NOTIFICATION, INITIATION & DETECTION DEVICES TO BE ADDED. AREAS OF WORK SHOWN IN THESE DRAWINGS ARE ONLY AREAS WITHIN RED HAWK'S SCOPE. SITE MAP: hw� • VM r--, E J0,- row ' -W'P W . 4%9�. I T AREA OF WORK PORTABLE P3 SCALE: "' = 1'-O" 16 8 6 4 2 0 917 134nu Avc SW, STE B-3 Evotm, WA 98204 P"omE: )42S) 818-3313 WA CLN REDHAHF901 C2P WA EL# REDHAHF8030D NICET Stamp NICET CERTIFICATION THESE FIRE ALARM DRAWINGS HAVE BEEN REVIEWED BY: MIKE SERESUN FIRE PROTECTION ENGINEERING TECHNOLOGY FIRE ALARM SYSTEMS - LEVEL III NICET CERTIFICATION # 101668 CERTIFICATION EXPIRES-11101/2024 Approvals Required Revisions ISSUE DATE BY DESCRIPTION 0 09/23/2024 SDF PERMIT SUBMITTAL SET Contract With SCOTT'S ELECTRIC SERVICE, LLC 23811 STATE ROUTE 2 MONROE, WA 98272 Contract Name WOODWAY HIGH SCHOOL PORTABLE #3 EDMONDS SD 7600 212TH ST. SW, EDMONDS, WA 98020 FIRE ALARM SYSTEM Sheet Title FIRE ALARM SYSTEM PROJECT INFO, CALC & FAS LAYOUT Key Plan Date: 09/23/2024 Job Number: 390031 Designer: SEAN D. FODOR Building Permit: Sheet Number FA=1 mOO SHEET 1 OF 1