FIR2024-0090+Fire_Alarm_Equipment_Specification_Sheets+9.24.2024_6.58.50_AM+4518671Date: 9/23/2024 RED HAWK FIRE PROTECTION Customer: SCOTT'S ELECTRIC 23811 STATE ROUTE 2 MONROE, WA 98272 Job #: 390031 System Type: FAS PORTABLE Project: WOODWAY HS PORTABLE P3 7600 212TH ST. SW EDMONDS, WA 98020 Material List of Data Sheets Item Manufacture Model Description 1 Simplex 4098-9714 Photoelectric Smoke Detector: White 2 Simplex 2099-9754 Manual Pull Station 3 Ditek DTK-2MHLP24FWB 24VDC Surge Suppressor; 2pr, 14-30VDC, 16-22awg 4 SPACEAGE E120V-GT 120VAC VOLTAGE PROTECTOR 5 Honeywell HPF-PS6 Remote 6A NAC Power Supply; 5- 3.OA Outputs 6 System Sensor P2WL Wall Horn w/ Strobe, Multi-cd (15, 30, 75, 95, 110,135 or 185cd) 7 System Sensor P2WK Wall Horn w/ Strobe, WP, Multi-cd (15, 30, 75, 95, 110 or 115cd) 8 UltraTech Batteries This page intentionally left blank i3 Simplex Datasheet TrueAlarm Analog Sensing UL, ULC, CSFM Listed, FM Approved* Features TrueAlarm Analog Sensors - Photoelectric and Heat, Standard Bases and Accessories TrueAlarm analog sensing You can use TrueAlarm analog sensing to digitally transmit analog sensor values with IDNet or MAPNET II two -wire communications. You can use True Alarm analog sensing with the following Simplex products: 4007ES, 4010, 4010ES, 4100ES, and 41000 series fire alarm control units (FACUs), and 4008 series FACUs with reduced feature set. 4020, 4100, and 4120 series FACUs, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET II operation Features compatible with the FACU Peak value logging with accurate analysis of each sensor for individual sensitivity selection Sensitivity monitoring meets NFPA 72 sensitivity testing requirements. The automatic individual sensor calibration check verifies sensor integrity Automatic environmental compensation, multi -stage alarm operation, and display of sensitivity directly in percent for each foot Display and print detailed sensor information in English Photoelectric smoke sensors features Sensitivity levels from 0.2% to 3.1 %. See TrueAlarm sensors for more information. Heat sensors features Three fixed temperature sensing thresholds: 135°F, 155°F and 190°F Rate -of -rise temperature sensing Utility temperature sensing Listed to UL 521 and ULC-SS30 General features Ceiling or wall mounting Listed to UL 268 7th Edition and ULC-S529 NEMA 1 rated. See TrueAlarm analog sensing product selection chart for more information. Louvered smoke sensor design enhances smoke capture by directing flow to chamber. Entrance areas are minimally visible when ceiling mounted Designed for EMI compatibility Magnetic testing Different bases support a supervised or unsupervised output relay, or a remote LED alarm indicator Additional base reference For isolator bases, refer to data sheet S4098-0025 For isolator2 bases, refer to data sheet S4098-0026 For sounder bases, refer to data sheet S4098-0028 For photo/heat sensors, refer to data sheet S4098-0024 , single address and S4098-0033 , dual address Description Digital communication of analog sensing TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. The control unit analyses the data, determines an average value, and stores it. Comparing the sensor's present value against its average value and time, determines an alarm or other abnormal condition. Intelligent data evaluation Monitoring each sensor's average value provides a continuously shifting reference point. A software filtering process compensates for environmental factors, such as dust and dirt, and component aging, to provide an accurate reference for evaluating new activity. This reduces the probability of false or nuisance alarms caused by shifts in sensitivity. Control unit selection The control unit stores peak activity for each sensor for evaluating specific locations. The host control unit determines the alarm set point for each TrueAlarm sensor, selectable as more or less sensitive as the individual application requires. Figure 1: 4098-9714 TrueAlarm photoelectric sensor mounted in base Timed/multi-stage selection You can program the sensor alarm set points for timed automatic sensitivity selection, such as more sensitive at night or less sensitive during day. You can program the control unit to provide multi -stage operation for each sensor. Sensor alarm and trouble LED indication Each sensor base's LED pulses to indicate communications with the unit. If the control unit determines a sensor is in alarm, is dirty, or has some other type of trouble, the details display at the control unit and the sensor's base LED turn on steadily. During a system alarm, an LED indicating a trouble returns to pulsing to help identify the alarmed sensors. TrueAlarm sensor bases and accessories Sensor base features Base mounted address selection Address remains with its programmed location Accessible from front, DIP switch under sensor General features Automatic identification provides default sensitivity when substituting sensortypes Integral red LED for power -on, pulsing, or alarm or trouble, steady on Locking anti -tamper design mounts on standard outlet box Magnetically -operated functional test *These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. see CSFM Listings 7272-0026:218, 7271-0026:231, 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4098-0019 Rev.31 06/2023 simplex TrueAlarm Analog Sensors - Photoelectric and Heat, Standard Bases and Accessories Sensor bases 4098-9792, standard sensor base 4098-9789, sensor base with wired connections 2098-9808 remote LED alarm indicator or 4098-9822 relay. The relay is unsupervised and requires separate 24 VDC. Supervised relay bases not compatible with 2120 CDT: 4098-9791, four -wire sensor base, use with remote or locally mounted 2098-9737 relay, requires separate 24 VDC 4098-9780, two -wire sensor base, use with remote or locally mounted 4098-9860 relay, no separate power required You can program supervised relay operation, and manually operate it from the control unit Includes wired connections for remote LED alarm indicator or 4098-9822 relay, relay is unsupervised and requires separate 24 VDC Sensor base options 2098-9737, remote or local mount supervised relay DPDT contacts for resistive or suppressed loads power limited rating of 3 A at 28 VDC non -power limited rating of 3 A at 120 VAC, requires external 24 VDC coil power 4098-9860, remote or local mount supervised relay SPDT dry contacts, power limited rating of 2 A at 30 VDC, resistive. Non -power limited rating of 0.5 A at 125 VAC, resistive 4098-9822, LED annunciation relay Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive or suppressed loads, power limited rating of 2 A at 28 VDC. Non -power limited rating of 1 /2 A at 120 VAC, requires external 24 VDC coil power 4098-9832, adapter plate Required for surface or semi -flush mounting to 4 in. square electrical box and for surface mounting to a 4 in. octagonal box You can use the 4098-9832 adapter plate for cosmetic retrofitting to an existing 6 3/8 in. diameter base product 2098-9808, remote red LED alarm indicator Mounts on single gang box Figure 2: Remote red LED alarm indicator Description TrueAlarm sensor bases contain integral addressable electronics that monitor the status of the detachable photoelectric or heat sensors. The sensors transmit digitalized output to the system fire alarm control unit every four seconds. You can change different TrueAlarm sensor types to meet location requirements. You can use this feature to substitute sensors during building construction. When conditions are temporarily dusty, you can install heat sensors without reprogramming the control unit. Although the control unit indicates an incorrect sensor type, the heat sensor operates at a default sensitivity and provides heat detection for building protection at that location. Mounting reference Figure 3: Mounting reference Electrical Box Requirements: (coxes are oy others) Wdho nflft in ft b-ox: 4' octagonal or 4' square. 1-112' deep. single gang. 2' deep Unth relay in the box : 4' octagonal or 4' square. 1.1,2' deep, wth 1-1.2" eIxerigon ring 4" 1102 mm) Square Box 4" (102 mml Octagonal Box Surface mount reference- 1.1,2' (38 mm) mnmum box depth Flush mount reference, mount even vMth final surtax or wM up to VV 164 mm) maximum rewss Supervised Relay Relay (mounts (mounts in vase electrical box or in base efactneal box) rematdy) FRelay )See 2-1,•2' X 1-1,7^ X 1' 1375in)(64men X38mmX254mm) Supervised RelaAmounts in base electrical box or rem40*. 241r X 1-1/4' X 11/32" (10?)(00.4mmX31.8mmXB6MM) ts—Emr NOTE: Rev(ew total wre Cowl, wire Sine, and socessones barg w+red to determine required box volume. L^ ff3.r8'(tff2mm) .i r Adapter Plate• required for - 1-4' mounbng to surface mounted boxes (6 4 mm) and 4' square flush box �.— 4-7,•8' (124 mm) .� 15�16' (24 mm) n TrupAhrm RAAPS Table 1: Product mounting - SKU reference Relay 14098-9822 ple 2 4098-9860 Haapter plate 4Uy)d-y)bJ2 TrueAlarm bases 4098-9780, 4098-9789, 4098-9791, Page 2 S4098-0019 Rev. 31 06/2023 simplex TrueAlarm Analog Sensors - Photoelectric and Heat, Standard Bases and Accessories TrueAlarm sensors Features Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors: - Selectable rate -compensated, fixed temperature sensing with or without rate -of -rise operation Table 2: Rated spacing distance between sensors Fixed Temp. Setting UL and ULC Spacing FM Spacing, Either Fixed Temperature Setting 135°F (57.2°C) 60 ft x 60 ft 20 ft x 20 ft (6.1 m) for fixed 190°F (88°C) (18.3 m) temperature only. RTI = Quick 50 ft x 50 ft (15.2 m) for fixed 40 ft x 40 ft 155°F (68°C) (112.2 m) temperature with either rate -of -rise selection. RTI = Ultra Fast Note: 190°F (88°C) ratings only apply to the 4098-9734 sensor. Smoke sensors Photoelectric technology sensing 360' smoke entry for optimum response Built-in insect screens 4098-9714 photoelectric sensor TrueAlarm photoelectric sensors use a stable, pulsed LED light source and a silicon photodiode receiver to deliver low power smoke sensing. There are three user -selectable sensitivities for special applications for each individual sensor: 0.2%, 0.5%, and 1 % for each foot. Standard sensitivity is 1.25% to 3.1 % for each foot. The fire alarm control unit can vary the sensitivity for normal applications between 1.25% and 3.1 % for each foot. Note: Fixed sensitivity settings higher than 1.0% for each foot are not UL268 7th Edition compliant. The sensor head design provides 360' smoke entry for response to smoke from any direction. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. Figure 4: 4098-9714 photoelectric sensor with base T� 2-1 V (54 mm) 4098-9733 and 4098-9734 heat sensors TrueAlarm heat sensors are self -restoring and provide rate - compensated, fixed temperature sensing with or without rate -of -rise temperature sensing. The sensor measures the local temperature for analysis at the fire alarm control unit. You can select rate -of -rise temperature detection at the control unit for either 15°F or 20oF, (8.3°C or 11.1 °C) for each minute. Fixed temperature sensing is independent of rate -of -rise sensing and you can program it to operate at 135°F or 155°F (57.2°C or 68°C). The 4098-9734 sensor provides an additional 190°F (88°C) set point. In a slowly developing fire, the temperature may not increase rapidly enough to operate the rate -of -rise feature. However, when the temperature reaches the rated fixed temperature setting, it triggers an alarm. You can program TrueAlarm heat sensors as a utility device to monitor for temperature extremes in the range of 32°F to 155°F (0°C to 68°C). This feature can provide freeze warnings, or alert you to HVAC system problems. Refer to panel specifications for availability. Figure 5: 4098-9733 heat sensor with base 77 —4-7/r (124 mm j— dieator I --LED status in 2-3V (60 mm) x Figure 6: 4098-9734 high temperature heat sensor with base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. Application reference Only choose sensor locations after careful consideration of the physical layout and contents of the area that you want to protect. Refer to N FPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, you can use a smoke sensor spacing of 30 ft (9.1 m) as a guide. For detailed application information including sensitivity selection, refer to 4098 Detectors, Sensors, and Bases Application Manual (574-709). Page 3 S4098-0019 Rev. 31 06/2023 simplex TrueAlarm Analog Sensors - Photoelectric and Heat, Standard Bases and Accessories TrueAlarm analog sensing product selection chart Table 3: TrueAlarm sensor bases, for use with sensors 4098-9714 and 4098-9733 SKU Color Description Compatibility Mounting requirements 4098-9792 White Standard sensor base No options 4 in. octagonal or 4 in. square box, 1 1/2 in. min. depth, or single 4098-9776 Black gang box, 2 in. min. depth 4098-9789 White Sensor base with connections remote alarm indicator or 4098-9789IND for remote LED alarm indicator or unsupervised relay 4098-98 4098 9822 unsupervised relay 4 in. octagonal or 4 in. square box 4098-9775 Black 4098-9791 Four -wire sensor supervised 2098-9737 supervised remote relay Note: NOT compatible White relay base with connections for LED indicator or unsupervised Note: 2098-9808 remote alarm indicator or with the 2120 CDT relay 4098-9822 unsupervised relay Box depth requirements depend on total wire count and wire size. See Table 5 4098-9780 Two -wire sensor supervised 4098-9860 supervised remote relay Note: NOT compatible White relay base with connections for LED indicator or unsupervised 2098-9808 remote alarm indicator or with the 2120 CDT relay 4098-9822 unsupervised relay Note: SKU numbers ending in IND are assembled in India. Refer to 4098 Detectors, Sensors, and Bases Application Manual (574-709) and 4098 Smoke/Heat Sensor Bases Installation Instructions (574-707) for additional information. Table 4: TrueAlarm sensors SKU Color Description Compatibility Mounting requirements 4098-9714 4098-9714-IND White Photoelectric smoke sensor Bases 4098-9775, 4098-9776, 4098-9792, 4098-9789, 4098-9791, and 4098-9780 Refer to base requirements 4098-9774 Black 4098-9733 White Heat sensor 4098-9778 Black 4098-9734 White High temperature heat sensor Note: SKUs are NEMA 1 rated. The 4098-9734 Heat Sensor is only compatible with IDNet on the 4100ES, 4010ES, and 4007ES Table 5: TrueAlarm sensor and base accessories SKU Description Compatibility Mounting requirements 2098-9737 Supervised relay, mounts remote or in base 4098-9791 base Remote mounting requires 4 in. octagonal electrical box or in. square box, 1 1/2 in. minimum depth 4098-9860 Supervised relay, mounts remote or in base 4098-9780 base Base mounting requires 4 in. octagonal electrical box box, 2 1/8 in. deep with 1 1/2 in. extension ring 2098-9808 Remote red LED alarm indicator on single Bases 4098-9789, 4098-9791, and Single gang box, 1 1/2 in. minimum depth gang stainless steel plate 4098-9780 4098 9822 Unsupervised relay, tracks base led status. Bases 4098-9789, 4098-9791, and 4 in. octagonal box, 2 1/8 in. deep with 1 Note: Only mounts in base electrical box. 4098-9780 1/2 in. extension ring Bases 4098-9792, 4098-9789, Required for surface or semi -flush 4098-9832 Adapter plate 4098-9791, and 4098-9780 mounted 4 in. square box and for surface mounted 4 in. octagonal box Note: 2098-9808 is NEMA 1 rated. Specifications Table 6: General operating specifications Specification Rating Communications and sensor supervisory power IDNet or MAPNET II communications, auto -selected, one address for each base Communications connections Screw terminals for in/out wiring, 18 to 14 AWG, 0.82 mm2 to 2.08 mm2 Remote LED alarm indicator current 1 mA typical, no impact to alarm current Remote LED alarm indicator and relay connections Color coded wire leads, 18 AWG, 0.82 mm2 UL listed operating temperature range 32°F to 100°F, 0°C to 38°C Page 4 S4098-0019 Rev. 31 06/2023 simplex TrueAlarm Analog Sensors - Photoelectric and Heat, Standard Bases and Accessories Table 6: General operating specifications Specification Rating Operating temperature range with 4098-9733 Heat Sensor 32°F to 122°F, 0°C to 50oC with 4098-9714 Smoke Sensor 15°F to 122T, -9°C to 50°C with 4098-9734 Heat Sensor 32°F to 1 SOT, 0°C to WC Storage temperature range 0°F to 140°F, -18°C to 60oC Humidity range 10%to 95% RH 0 to 4000 ft/min, 0 to 1220 m/min Frost white or black 4098-9714 smoke sensor air velocity rating Housing color Table 7: 4098-9791 Base with supervised remote relay 2098-9737 bpecrncation Kating Externally supplied relay coil voltage 18 VDC to 32 VDC, nominal 24 VDC Supervisory current 270 NA, from 24 VDC supply Alarm current with 2098-9737 relay 28 mA, from 24 VDC supply sor base options for contact Table 8: 4098-9780 Base with supervised remote relay 4098-9860 Specification Rating Power ISupplied from communications Table 9: 4098-9822 Unsupervised relay, requirements for bases 4098-9789, 4098-9791, and 4098-9780 Specification 0 jff IRating Externally supplied relay coil voltage 18 VDC to 32 VDC, nominal 24 VDC Supervisory current Supplied from communications Alarm current 13 mA from separate 24 VDC supply Note: See Sensor base options for contact ratings. Page 5 S4098-0019 Rev. 31 06/2023 Osimplex TrueAlarm Analog Sensors - Photoelectric and Heat, Standard Bases and Accessories © 2023 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. Simplex, and the product names listed in this material are marks or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). S4098-0019 Rev.31 06/2023 asimplEx UL, ULC, CSFM Listed, FM Approved, MEA (NYC) Acceptance* Manual fire alarm stations for general purpose applications: • Operation complies with ADA requirements • Pull lever protrudes when alarmed • Break -rod is supplied (use is optional) • Screw terminals for wiring connections • Tamper resistant reset key lock (keyed same as Simplex fire alarm cabinets) Operation types include: • Single action • Double Action, Breakglass or Push Type • Institutional Model, key operated only • Optional NO GRIP Single Action Retrofit Kits are available with a more easily operated pull lever for applications where anticipated users may find the standard station lever difficult to activate • Optional Local Alarm cover • Optional pre -signal and annunciator contacts Multiple mounting options: • Surface or semi -flush with standard boxes or matching Simplex boxes • Flush mount adapter kit UL listed to Standard 38 Jnpil Activation of the Simplex single action manual stations requires a firm downward pull to activate the alarm switch. Completing the action breaks an internal plastic break -rod (visible below the pull lever, use is optional). The use of a break -rod can be a deterrent to vandalism without interfering with the minimum pull requirements needed for easy activation. The pull lever latches into the alarm position and remains extended out of the housing to provide a visible indication. Double Action Stations (Breakglass) require the operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station. Double Action Stations (Push Type) require that a spring loaded interference plate (marked PUSH) be pushed back to access the pull lever of the single action station. Station reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. (If the break - rod is used, it must be replaced.) Station testing is performed by physical activation of the pull lever. Electrical testing can be also performed by unlocking the station housing to activate the alarm switch. Multi -Application Peripherals Non -Coded, Non -Addressable Manual Stations; 2099 Series Single and Double Action Operation Single Action Station Double Action Station (Breakglass) 0®0 PULL DOWN O Double Action Station (Push Type) O Local Fire Alarm Cover Option �PIU� II U�I�I Single Action Station with 4099-9805 NO GRIP Institutional Cover Retrofit kit Institutional Stations activate by key operation only allowing access for manual alarms to be initiated by authorized personnel. Operation requires key insertion and opening of the station cover. Single Action Station NO GRIP Retrofit Kit 4099-9805. For applications such as California Building Code, Title 24, which requires "Controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist" the model 4099-9805 Retrofit kit provides a more easily operated pull lever compared to standard stations. * Refer to page 2 for models with MEA acceptance. These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7150-0026:175 (Pull Boxes) and 7150-0026:0224 (NO GRIP Retrofit Kit) for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S2099-0007-18 12/2014 Pre -Signal Option activates when the lever is pulled. General alarm initiation requires a key to activate a keyswitch located behind the pull lever. Station Reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. If the break -rod is used, it must be replaced. Testing requires physical activation of the pull lever (except for institutional stations). VIM. T"TRITZ7.0"Iffl- Refer to NFPA 72, the National Fire Alarm and Signaling Code, and all applicable local codes for complete requirements for manual stations. Product Selection Single Action Models (General Alarm) .. .WITMER• The following summarizes the basic requirements. 1. Stations shall be located in the normal path of exit and distributed in the protected area such that they are unobstructed and readily accessible. 2. Mounting shall be with the operable part not less than 42 in (1.07 m) and not more than 48 in (1.22 m) above floor level. 3. At least one station shall be provided on each floor. Additional stations shall be provided to obtain a travel distance not more than 200 ft (61 m) to the nearest station from any point in the building. 4. When manual station coverage appears limited in any way.additional stations should be installed. Model MEA Pre -Signal Annunciator Contacts, N.O. Annunciator Contacts, N.C. Local Alarm Cover Institutional Cover Mounting Notes 2099-9754 ✓ 1 2099-9101 ✓ ✓ 2099-9102 ✓ J 2 2099-9107 ✓ J 2099-9755 It ✓ 1 2099-9762 If ✓ 1 Double Action Models (General Alarm) Model MEA Break -Glass Push Pre -Signal Annunciator Contacts N.O. Annunciator Contacts N.C. Mounting Notes 2099-9103 ✓ ✓ 1 2099-9104 ✓ J J 2099-9105 ✓ ✓ ✓ 2 2099-9108 J ✓ J 2099-9756 ✓ ✓ 1 2099-9757 ✓ J J 2099-9758 ✓ ✓ ✓ 2 2099-9759 ✓ ✓ J Accessories Model Description 4099-9805 Retrofit Kit for field conversion of a single action station to a NO GRIP station; (reference Instructions 579-1007) 2099-9803 Replacement breakglass (standard, English) 2099-9804 Replacement break -rod 2099-9819 Flush adapter kit, black (refer to page 4) 2099-9820 Flush adapter kit, beige (refer to page 4) 2099-9822 Replacement retaining clip for breakglass 2099-9828 Institutional cover kit 2975-9178 Red, surface mount box, sheet metal, 5-3/16" H x 4" W x 2-3/16" D (127 mm x 102 mm x 56 mm) 2975-9022 1 Red, cast aluminum surface mount box, 5" H x 3-7/8" W x 2-3/16" D (127 mm x 98 mm x 56 mm) Notes: 1. These models can be semi -flush mounted using a standard single gang 2-1/2" (64 mm) deep switch box. DO NOT RECESS BOX, mount box flush or with 1/16" (2 mm) maximum protrusion. These models can also be surface mounted on a Wiremold box model number V5744S, 4-5/8" H x 2-7/8" W x 2-1/4" D (117 mm x 73 mm x 57 mm). 2. For surface mount, these models require 2975-9178 or 2099-9022 boxes. For semi -flush mount, these models require a 4" (102 mm) square box with a single gang cover plate (see diagram on page 3). Additional Non -Addressable Manual Stations Releasing Stations Data Sheet S2099-0010 Addressable Manual Stations Standard Addressable Data Sheet S4099-0005 Stations for hazardous locations (Ring -Pull) S2099-0008 Addressable for Releasing S4099-0006 Metal housing and explosion-proof/weather-proof stations (T-Handle) S2099-0009 Wire Guard (addr./non-addr.) S2099-0004 S2099-0007-18 12/2014 Surface Mounting Reference 2975-9178 Box 5-3/16" H x 4" W x 2-3/16" D Knockouts located (132 mm x 102 mm x 56 mm) /top and bottom (ordered separately) \ 011 10 5" (127 mm) 2975-9022 Cast Box 5" H x 3-7/8" W x 2-3/16" D (127 mm x 98 mm x 56 mm) (ordered separately) n FIRE ®ALARM PULL DOWN 0 Simplex 2975-9178 box (shown for reference) Side View J Station cover hinges open for 0 installation access Access for 3/4" threaded conduit located top and bottom �SImpiEX _L k 1" (25.4 mm) �3-3/4" (95 mm)� Semi -Flush Mounting Reference Single Gang Box Mount Single gang box, 2-1/2" deep (64 mm), RACO #500 or equal (supplied by others) o C CC 0 4" Square Box Mount 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO #231 or equal (supplied by others) FIRE ®ALARM £35implEx 0 ITC Mount flush or with 1/16" (2 mm) maximum extension°DO NOT RECESS 4" Square box with cover plate ---------- J i O ' i i Station side view Single gang cover plate, 3/4" (19 mm) extension, RACO #773 or equal (supplied by others) Single gang box outline Wall surface 3 Semi -Flush Mount Side View S2099-0007-18 12/2014 Flush Mount Reference 8" (203 mm) 6" (152 mm) Specifications DC 4-3/4" (121 mm) 6-3/4" (171 mm) Front View Flush mount adapter kit 2099-9819, Black 2099-9820, Beige I Hole cutout must be a minimum of 6" H by 5" W (152 mm by 127 mm) Wall surface Box must be recessed into wall 1" to 1-1/8" (25.4 mm to 29 mm) 0 0 4-11/16" (119 mm) square box, 2-1/8" (54 mm) minimum depth (by others) Side View Wire Connections Screw terminal for in/out wiring, for 18 to 14 AWG wire UL Listed Temperature Range 32' to 120° F (0' to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100' F (38' F) Housing Color Red with white raised lettering Material Housing and pull lever are high impact polycarbonate Pull Lever Color White with red raised lettering Housing Dimensions 5" H x 3-3/4" W x 1" D (127 mm x 95 mm x 25 mm) TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association (NFPA). f3eS i m p I :X Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA S2099-0007-18 12/2014 www.simplex-fire.com © 2014 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. DN-6726:D • H-240 NBG-12LX Addressable Manual Pull Station ,General The Notifier NBG-12LX is a state-of-the-art, dual -action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire -ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-10 or SB-1/0) or semi - flush mounted. Semi -flush mount to a standard single - gang, double -gang, or 4" (10.16 cm) square electrical box. • Smooth dual -action design. • Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Up to 99 NBG-12LX stations per loop on CLIP protocol loops. • Up to 159 NBG-12LX stations per loop on FlashScanO pro- tocol loops. • Dual -color LED blinks green to indicate normal on FlashScanO systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications • Shipping Weight: 9.6 oz. (272.15 g) • Normal operating voltage: 24 VDC. • Maximum SLC loop voltage: 28.0 VDC. • Maximum SLC standby current: 375 pA. • Maximum SLC alarm current: 5 mA. • Temperature Range: 32°F to 120°F (0°C to 49°C) • Relative Humidity: 10% to 93% (noncondensing) • For use indoors in a dry location �J NOTI FI ER° by Honeywell The NBG-12LX Addressable Manual Pull Station Installation The NBG-12LX will mount semi -flush into a single -gang, dou- ble -gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-1/0 sur- face backbox. If the NBG-12LX is being semi -flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi -flush mounting with 4" (10.16 cm) or double -gang boxes (not with single -gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 — 159 on FlashScanO systems, 1 — 99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non -coded, with a key - operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red -colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi -flush mounting on a standard single -gang, double -gang, or DN-6726:D • 4/13/2012 — Page 1 of 2 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information NBG-12LX: Dual -action addressable pull station. Includes key locking feature. (Listed for Canadian and non -Canadian appli- cations.) NBG-12LXSP: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. SB-10: Surface backbox; metal. SB-1/0: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. NY -Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL/ULC Listed: S692 (listed for Canadian and non -Cana- dian applications). • MEA:67-02-E. • CSFM:7150-0028:0199. • FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). • BSMI: C1313066760047. • U.S. Coast Guard. • Lloyd's Register. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIERO and FlashScanO are registered trademarks of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Aso 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. INSINISfW68MMIFUTRRIS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — DN-6726:D • 4/13/2012 DITEK's DTK-2MHLPF Seric— of low voltage surge protectors provide robust protection In a compact package. This series was designed to remove load instead of shorting to ground. Convenient field -replaceable modules offer ease of Installation, and the Snap -Track base system allows installers to protect multiple circuits while utilizing a common ground point. DTK-2MHLPF Series Modular Low Voltage Surge Protectors ve Product Features DTK-2MHLP 5F 12F 24F 36F 413F 75F > Protects (2) low voltage circuit pairs Service voltage: 5V 12V 24V 36V 48V 75V per module > Hybrid design utilizing SAD and GDT MCOV- 6V 18V 33V 48V 64V 90V technologies Clamping voltage: 6.8V 21 6V 39V 57V 76V 108V > Opens circuit when compromised Protection Modes: Common Mode (L-G) > Field -replaceable modular design with single point ground for fast and Surge Current Rating: 20.000A easy installation Max. Continuous 1A Six voltage configurations available Current: to protect various types of circuits Failure Mode: Open Circuit > Hardwired multi -base mounting system allows protection for up to (10) pairs with a common ground Mechanical Sivecifications > Suitable for use on both AC and DC Base Connection Method: Hardwired terminals. 30-12 AWG low voltage circuits Module Connection Method: Edge card into nxounling base Housing: ABS Applications Operating Temperature: -40°F - 158`F (40`C - 70'C) > Fire Alarm Panel SLC. PIV and IDC Maximum Humidity: 951/6 non -condensing Circuits Module Module with Base > Burglar Alarm Panel IDC Circuits Dimensions: 2.1' L x 1.4' 1h' x 1.9' H 3.25' L x II.5''A' x 2.6' H 4-20mA Current Loops (53 mm x 36 mm x 48 mm) 183 rrm x 38 mm x 66 mm) Weight: 1.2 oz (34 g) 2.8 oz (79 g) Accessories > To order module with base, add (tuallit' "Approvals VVB" to end of part number Certifications: UL497B > Test Module Kit, pin DTK-2MHLPTM Warranty: 10 Year Limited Warranty NFPA USTED DITEK Surge Protection, Largo, FL 33771 • Sa4&W.753.2345 &www.diteksugppmWAion.com • SPS• 100010.003 Rev 4 04121 E.n PWNA n no Owe NUr 10 a+wn nw to Mvsw a uano 1101 co*OAO WIN caopOrakn awven no vwDvoa ft aW u*drw a1 6004 b w owM409'I= b w* OF M rAvr~ Or M any •ton Or Orono* DITE Base Part Numbers and Dimensions DTK-2MHLPF Series Signaling Circuit Modular Surge Protectors DTK-MB10 2 3.25" H x 1.50" W (82.5 mm x 38.1 mm) DTK-2MB 4 3.25" H x 3.00" W (82.5 mm x 76.2 mm) DTK-3MB 6 3.25" H x 4 50" W (82.5 mm x 114.3 mm) DTK-4MB 8 3.25" H x 6.00- W (82.5 mm x 152.4 mm) DTK-5MB 10 3.25" H x 7.50' W (82.5 mm x 190.5 mm) DTK-2M.B DTK-3MB DTK-4?AB DTK-5MB ® E=CLAMM Ff2ov.Gr ..& cyst ift --dm=L InvAt Date, j` LED oN In Ske J_ Insp DI_ J �Insp pl_ H iz FA _ _ AIAFN 6 afY1Y 'r: ;.Ht p:Acai A 18 Standard Features: • Available in 120 VAC • ANSI/UL Listed 1449 4th Edition, Type 2 • CSA C22.2 No. 269.2-17 2nd edition, Type 2 • Includes lockout & labels per NFPA 72 2013 10.6.5.2 • Surface or conduit mounting • Diagnostic indicator light • Self restoring • 3 Wire device (188"" length) 1 Made In U.S.A. NFPA �- Uses UL Recognized Components Hybrid Surge Protection Device Safety and performance is what Eclips is all about. While there are many varying criteria to be considered for surge protective devices (SPD), if the design engineer neglects the importance there can be serious implications for the client and equipment. Every piece of electrical equipment is designed to operate at a specified nominal voltage. Typically equipment is designed to handle minor variations. However external sources such as lightning, motors, and short circuits cause wild and damaging variations. Critical systems wired to your electrical service like Fire Alarm Control Panels (FACP), Mass Notification systems, amplifiers, motors, pumps (HVAC), power boosters and many more must require appropriate levels surge protection. The E120 series is an ideal choice for your 120V AC applications_ because it has the robustness not only to absorb a spike, but to clamp long enough to trip the branch circuit breaker and still be functional for additional surges. The number one cause of destruction, degradation and down- time of critical electrical equipment is from power surges and lightning strikes_ The El20V-GT device is an ideal solution to protect equip- ment. UL listed it maintains system integrity and protects against transients introduced into / onto electrical lines via poor atmospheric and utility conditions as well as internally gener- ated inductive loads and transient TVSS. It reduces system downtime associated with power surges and lightning strikes. Prevents destruction and degradation of electrical components in the system. Fix your nuisance and non -billable service calls as a result of transients and poor power quality and show your customer you care about system integrity. ISO 9001 REGISTERED COMPANY Space Age Electronics, Inc. www.ISAE.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2013 LT10629 Rev.7 1/2 No Excuses, Just Solutions! rSPACEAGE ELECTRONICS, INC. Specifications: All 120volt AC equipment will have Transient Voltage Surge Suppression (TVSS) protection manu-factured by Space Age Electronics, Inc., part number E120V--GT ECLIPS Brand. The Unit shall be ANSI/UL listed to standard 1449, 4th edition. The unit will be labeled clearly with indelible ink. Mounting can be conduit mounted with a %" pipe threaded nipple to secure in panel, or surface panel mount with 2 external mounting holes. The unit shall have thermal fuses to protect against fire in short circuit conditions. The E120V will have 18" long, 14 gauge wires (3x) ground wire must be green. The enclosure will be a non dielectric material UL94 QMFZ2/8 grade material providing UV protection. The unit shall provide visual indication (LED) that unit is protecting and functioning. Specifications - Performance: Short Circuit Current Rating (SCCR) Enclosure Material VPR=700(L — N) 700 (L — G) 600 (N — G) Capacitance Clamping Response Time Current Max Operating Voltage (MCOV) : Design Operation Indicators 1OKA UL94 QMFZ2/8 (green) < 2,000 pf < 5 nanoseconds Non -Load Bearing 140 volts AC, 50/60 Hz Thermally Fused Hybrid LED Specifications - Compliance: Wiring Diagram: Specifications - Operating: Service Voltage : 120 Single Phase Circuits Protected : L-N L-G N-G Connection Type : Hardwired Installation Configuration : Parallel Specifications - Physical: Weight Dimensions Operation Temperature Mechanical Drav UL Listed : 1449 4th Edition - VZCA 1.5" File Number: E319370 Vol. 1 Sec. 1 Breaker panel 0 0 ® L� em ®® O .a0000000 � O Space Age Electronics, Inc. www.ISAE.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! Y W E01 2.6" Protected Device ,Ill�j r4 Ordering Information: Part # Description 5.2oz 2.75" x 1.55" x 4" long -40 to +850 C E120V-GT 120V Hybrid Surge Protective Device ELOCK-FA Circuit Lockout Kit This document is subject to change without notice, see doc # ED0479 for legal disclaimer LT10629 Rev.7 2/2 SERIES 6 Amp and 10 Amp, 24 Volt Power Supplies The PS Series are independently configurable power supplies, allowing you to pair any input with any output, and feature LED diagnostics for troubleshooting. The PS Series is a remote power supply line from Honeywell Power Products and is a direct replacement for the HPF-24S6/8. The HPF-PS6 is a 6 amp and the HPF-PS10 is a 10 amp, remote power supply with battery charger that may be connected to any 12 or 24 volt fire alarm control panel (FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs (notification appliance circuits) configured as either Class B or Class A (requires the ZNAC-PS option card) with multiple sync protocol options. The PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door holders, and otherfire alarm system peripherals. The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. The HPF-PS6E and H PF-PS10E are models rated for 240V operation. FEATURES AND BENEFITS • Up to five (6 amp model) or seven (10 amp model) independently -configurable, power - limited output circuits for: —Class B and/or Class A NACs —Class B and/or Class A resettable or non- resettable 24V auxiliary power —door holder power • Converts from Class B to Class A wiring without losing any outputs using the ZNAC- PS converter card (sold separately) • Optimal for powering four -wire smoke detectors, annunciators, and other system peripherals requiring regulated power • Optional addressable control, monitor, and relay modules and power -supervision relay (EOLR-1) • Configurable for ANSI° Temporal or Temporal coded output • UL-Listed NAC synchronization using System Sensor', Wheelock', Gentex°, or AMSECO° appliances • Synchronization can be triggered from FACP NAC/remote sync outputs, cascaded power supply, or a control module, single or multi, which may be housed within the power supply cabinet • Ability to cascade up to four power supplies • Two (6 amp model) orthree (10 amp model) fully -isolated input/control circuits which can be programmed to any output • Two Form C normally -closed trouble relays for AC Trouble and General Trouble • 6 or 10 amp full load output, respectively, with 3 A maximum/circuit • Individual NAC power and trouble LEDs for diagnostic efficiency • Trouble history mode for diagnostic support • Wide range end -of -line supervision value (normal: 2-27K ohms) • Selectable earth fault detection (enable or disable) • AC trouble report delay timer • Completely configurable via onboard DIP switches, no extra software required • Self-contained in compact, locking cabinet constructed of heavy gauge steel with a corrosion -resistant powder coat chip and scratch -resistant finish • Cabinet designed with ten double knockouts and a removable door for ease of installation and wiring • Includes integral battery charger capable of charging up to 33 AH batteries • Cabinet can house two 7 AH or 18 AH batteries • Battery charger may be disabled via DIP switch for applications requiring larger batteries and external battery charger • Removable terminal blocks accommodate up to 12 AWG (3.1mm2) wire • Works with any UL 864 FACP which utilizes an industry -standard reverse -polarity notification circuit HPF-PS61101E HPF-PS68/108/E Honeywell ORDERING INFORMATION HPF-PS6: 6.0 A,120 VAC remote charger power supply in a lockable, metal enclosure, red HPF-PS613: 6.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, black HPF-PS6E: 6.0 A, 240 VAC remote charger power supply in a lockable, metal enclosure, red HPF-PS10:10.0 A,120 VAC remote charger power supply in a lockable, metal enclosure, red HPF-PS10B:10.0 A,120 VAC remote charger power supply in a lockable, metal enclosure, black HPF-PS10E:10.0 A, 240 VAC remote charger power supply in a lockable, metal enclosure, red ZNAC-PS: Optional Class A converter card, sold separately TC81ON1013: Addressable Control Module for one Class B or Class A zone of supervised, polarized Notification Appliances. Notification Appliance Circuit option requires external24 VDC to power notification appliances. TC81OR1024: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch TC809A1059: Addressable Monitor Module for one zone of normally open dry -contact initiating devices. Includes plastic cover plate and end -of -line resistor. Module may be configured for either a Class B or Class A TC809D1004: Dual Monitor Module. Same as TC809A1059 except it provides two inputs for Class B wiring only TC822A1010: Provides two monitored inputs and two Form-C relays. Functions in Class B wiring only XP6-C: Six -circuit supervised control module XP6-R: Six Form-C relay control module EOLR-1:12/24 VDC end -of -line relay for monitoring four -wire smoke detector power BAT-1270-BP: Battery,12 volt, 7.0 AH, 5-pack (two required) BAT-12180-BP: Battery, 12 volt, 18AH, 2-pack BAT-12330: Battery,12 volt, 33AH SEISKIT-MULTI-1: Seismic kit for the PS Series. Includes bracket and hardware for two 7AH or two 18AH batteries. Page 2 of 3 — DH-61094:C • 3/10/2021 P.' SERIES TECHNICAL SPECIFICATIONS PRIMARY (AC) POWER H PF-PS6(B): 120 VAC, 50/60 Hz, 5.OA maximum HPF-PS10(B):120VAC, 50/60 Hz, 6.2 A maximum HPF-PS6E: 240 VAC, 50/60 Hz, 2.7A maximum HPF-PS10E: 240 VAC, 50/60 Hz, 3.5A maximum Wire Size: #12-14 AWG with 600 V insulation COMMAND INPUT CIRCUIT Trigger Input Voltage: 9 to 32 VDC Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 -16 V) RELAY CIRCUITS Trouble Contact Rating: 4 A at 24 VDC OUTPUT CIRCUITS • 24 VDC filtered • HPF-PS6(B): T138-TB9 -1A Regulated, 3A special applications; TB10-TB12 - 0.3A Regulated, 3A special applications • HPF-PS10(B): T138-TB11-1.5A Regulated, 3A special applications; TB12-TB14 - 0.3A Regulated, 3A special applications • 6.0 A (H PF-PS6) or 10.0 (HPF-PS10) maximum total continuous current for all outputs Honeywell Power Products 12 Clintonville Road Northford, CT06472-1610 203.484.7161 www.honeywellpower.com SECONDARY POWER (BATTERY) CHARGING CIRCUIT • Supports lead -acid batteries only • Float -charge voltage: 27.6 VDC • Maximum current charge:1.5 A • Maximum battery capacity:18 AH (inside cabinet) • Maximum battery charging capacity: 33 AH (external cabinet) PHYSICAL Dimensions: 20.0"H x 14.5"W x 3.5"D (cm: 50.8H x 36.83W x 8.9D) Weight: with two 7Ah batteries is 24 pounds (10.9 kg), with two 18 AH batteries is 39 pounds (17.7 kg) STANDARDS AND CODES The HPF-PS complies with the following standards: NFPA 72: National Fire Alarm Code UL 864: Standard for Control Units for Fire Alarm Systems (NAC expander mode) UL 1481: Power Supplies for Fire Alarm Systems AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S24562 CSFM: 7315-1637:0505 FDNY Approved FM Approved DH-61094 I C 1 03/21 ©2021 Honeywell International Inc. THE FUTURE Is WHAT WE MAKE IT Honeywell DN-60918:B Indoor Selectable -Output Horns, Strobes, and Horn J Strobes for Wall Applications General The L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower cur- rent draws and modern aesthetics. With white and red plastic housings, standard and small footprint devices, and plain, FIRE -printed devices, L-Series can meet virtually any applica- tion requirement. The L-Series product line of wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually elim- inating costly and time-consuming ground faults. To further simplify installation and protect devices from con- struction damage, L-Series utilizes a universal mounting plate for all standard and compact models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela set- tings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Features • Updated modern aesthetics. • Small profile devices for Horns and Horn Strobes. • Plug-in design with minimal intrusion into the back box. • Tamper -resistant construction. • Automatic selection of 12- or 24-volt operation at 15 and 30 candela. • Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185. • Horn rated at 88+ dBA at 16 volts. • Rotary switch for horn tone and two volume selections. • Universal mounting plate for all standard and all compact wall units. • Mounting plate shorting spring checks wiring continuity. before device installation. • Electrically Compatible with legacy SpectrAlert® and SpectrAlert Advance devices. • Compatible with MDL3 sync module. • Listed for wall mounting only. Architectural/Engineering Specifications General: L-Series standard horns, strobes, and horn strobes shall mount to a standard 2" x 4" x "/8" back box, 4" x 4" x 11/2" back box, 4" octagon back box, or double -gang back box. L-Series compact products shall mount to a single -gang 2" x 4" x 17/8" back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard -size models and a separate universal mounting plate shall be used for mounting compact wall models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•CircuitTM Module accessory, shall be powered from a non -coded notifi- cation appliance circuit output and shall operate on a nominal N OTI F 1 E Re by Honeywell P2RL F F I.yam R� R3t y'� - E �� v i E P2GWL SGWL HWL 12 or 24 volts. When used with the Sync -Circuit Module, 12- volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated c appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unaltered power supply. Strobes and horn strobes shall have field -select- able candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe. The strobe shall be a L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appli- ance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/ reflector system. DN-60918:B • 5/19/17 — Page 1 of 4 Horn Strobe Combination. The horn strobe shall be a L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visi- ble signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (contin- uous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module. The module shall be a Sync -Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while oper- ating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/6" x 411/16" x 21/8" back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. PHYSICAL/ELECTRICAL SPECIFICATIONS • Standard Operating Temperature: 320F to 120°F (0°C to 49°C). • Humidity Range: 10 to 93% non -condensing. • Strobe Flash Rate: 1 flash per second. • Nominal Voltage: Regulated 12 DC or regulated 24 DC/ FWR1 (full wave rectified). • Operating Voltage Range2: 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal). • Operating Voltage Range: MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal). • Input Terminal Wire Gauge: 12 to 18 AWG. • Wall -Mount Dimensions (including lens): 5.6" L x 4.7" W x 1.25" D (143 mm L x 119 mm W x 32 mm D). • Compact Wall -Mount Dimensions (including lens): 5.26" L x 3.46" W x 1.93" D (133 mm L x 88 mm W x 49 mm D). • Horn Dimensions: 5.6" L x 4.7" W x 1.25" D (143 mm L x 119 mm W x 32 mm D). • Compact Horn Dimensions: 5.25" L x 3.45" W x 1.25" D (133mm L x 88mm W x 32mm D). NOTE. 1. Full Wave Rectified (FWR) voltage is a non -regulated, time - varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 cd and 30 cd. L-Series Drawings Compact Horn 3.46 1.25 0 00000 0 0000000000000 0000000000000 0000000000000 o000000000000 .27 00000000000 • 000000000000. 0000000000000 00000oo0o0a0o 0oi�l1�0�1p0�0 o 00�000000 0 Compact Combo 3.46 77�mnoo 5.27 Horn mo 47 .7 age 2 of 4 — DN-60918:B • 5/19/17 UL Current Draw Data UL MAX. HORN CURRENT DRAW (MA RMS) UL MAX. STROBE CURRENT DRAW (MA RMS) Candela 8-17.5 Volts 16-33 Volts DC DC FWR 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 The 3.1 k is the sound of the mini -horns. The EM (which stands for Electro-mechanical) is the sound of the SpectrAlert Advance line which uses an algorithm that hops frequencies between 2Hz and 4Hz. Sound Pattern dB 8-17.5 Volts 16-33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non -Temporal High 43 47 54 Non -Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL MAX. CURRENT DRAW (MA RMS), 2-WIRE HORN STROBE, CANDELA RANGE (15-115 CD) The 3.1 k is the sound of the mini -horns. The EM (which stands for Electro-mechanical) is the sound of the SpectrAlert Advance line which uses an algorithm that hops frequencies between 2Hz and 4Hz. DC Input: 8-17.5 Volts DC Input: 16-33 Volts FWR Input: 16 FWR 15 cd 30 cd 15 cd 30 cd 75 cd 95 cd 110 cd 135 cd 185 cd 15 cd 30 cd 75 cd 95 cd 110 cd 135 cd 185 cd Temporal High 98 158 54 74 121 142 162 196 245 83 107 156 177 198 234 287 Temporal Low 93 154 44 65 111 133 157 184 235 68 91 145 165 185 223 271 Non -Temporal High 106 166 73 94 139 160 182 211 262 111 135 185 207 230 264 316 Non-TemporalLow 93 156 51 71 119 139 162 190 239 79 104 157 175 197 235 283 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 81 105 155 177 196 234 284 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 68 90 145 166 186 222 276 3.1K Non -Temporal High 99 162 69 90 135 157 175 208 261 104 131 177 204 230 264 326 3.1K Non -Temporal Low 93 156 52 72 119 138 162 192 242 77 102 156 177 199 234 291 DN-60918:B • 5/19/17 — Page 3 of 4 HORN TONES AND SOUND OUTPUT DATA: HORN AND HORN STROBE OUTPUT (DBA) The 3.1 k is the sound of the mini -horns. The EM (which stands for Electro-mechanical) is the sound of the SpectrAlert Advance line which uses an algorithm that hops frequencies between 2Hz and 4Hz. In the coded positions, temporal coding must be provided by the NAC. If the NAC voltage is held constant, the horn output will remain constantly on. Pos. Sound Pattern dB 8-17.5 Volts 16-33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 9t Coded High 85 90 90 10t 3.1 KHz Coded High 84 89 89 tSettings 9 and 10 are not available on the 2-wire horn strobes. Agency Listings and Approvals The listings and approvals below apply to L-series devices. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UUULC-Listed — S4011 Wall Horn Strobes — S5512 Wall Strobes — S5512 Wall Horns — S5512 Strobe -only ALERT devices • FM Approved (All except ALERT models) • CSFM Listed: 7135-1653:0503 (Wall Horns and Wall Horn Strobes), 7125-1653:0504 (Wall Strobes) Product Line Information WALL HORN STROBES P2WL(A)(-E)(-F), P2RL(A)(-E)(-F). 2-Wire, Horn Strobe (White, Red). P2GWL(A)(-E)(-F), P2GRL(A)(-E)(-F). 2-Wire, Compact Horn Strobe (White, Red). P2WL(A)-P, P2RL(A)-P. 2-Wire, Horn Strobe, Plain (White, Red). P2WL-SP, P2RL-SP. 2-Wire, Horn Strobe, FUEGO (White, Red). WALL STROBES SWL(A)(-E)(-F), SRL(A)(-E)(-F). Strobe, Red (White, Red). SGWL(A)(-E)(-F), SGRL(A)(-E)(-F). Compact Strobe (White, Red). SWL(A)-P, SRL(A)-P. Strobe, Plain (White, Red). SRL-SP. Strobe, FUEGO (Red). SWL-CLR-ALERT. Strobe, ALERT (White). SWL-ALERT. Strobe, Wall, Amber Lens, ALERT (White). HORNS HWL(A), HRL(A). Horn (White, Red). HGWL(A), HGRL(A). Compact Horn (White, Red). ACCESSORIES TR-2W, TR-2. Universal Wall Trim Ring (White, Red). SBBWL, SBBRL. Wall Surface Mount Back Box (White, Red). SBBGWL, SBBGRL. Compact Wall Surface Mount Back Box (White, Red). NOTE. `A" suffix indicates ULC-Listed model. ULC-listed devices include required French labeling. See Agency Listings for listing details. NOTE. `A" suffix indicates ULC-listed models, ULC models have FIRE/FEU marking on cover. NOTE. ULC-listed models add "-E" suffix for English only "FIRE" marking on cover. NOTE. ULC-listed models add "-F" suffix for French only "FEU" marking on cover. NOTIFIERO and SpectrAlertO are registered trademarks and Sync•CircuitTM is a trademark of Honeywell International Inc. ©2017 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISD 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. INGINMN6 & MhNUFUTUAW All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4 — DN-60918:6 • 5/19/17 O,�� SYSTEM � SENSOR - Outdoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAIWO Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field -selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from —40°F to 151 °F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Listed for ceiling or wall mounting Agency Listings SIGNALING L FM MEA 7300-1653:187 (outdoor strobes) LISTED approved 7125-1653:188 (horn strobes, S4011 (chimes, horn strobes, horns) APPROVED pp chime strobes) S3593 (outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189 (horns, chimes) i f o m S V s t e rn S e n s o r SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40oF to 151°F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field -selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and - out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock -outs located on the back eliminate the need to drill holes for screw -in mounting. Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch knock -outs at the back. A screw -in NPT plug with an O-ring gasket for a watertight seal is included with each back box. AVDS115-02. 12/3/2019 • Page 1 SpectrAlert Advance Outdoor Horn, Strobe, and Horn StrobeSpecifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•CircuitTM Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40 and 151 degrees Fahrenheit from a regulated DC or full - wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non -coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature —40°F to 151 °F (-40oC to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MLD3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 2.5-D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7-L x 5.1-W x 2.0-D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS115-02 • 12/3/2019 • Page 2 UL Current Draw Data 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non -Temporal High 57 56 69 75 95 NA NA 181 176 Non -Temporal Medium 42 50 60 69 110 NA NA 202 195 Non -Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 Max. Current Draw (mA RMS), 2-Wire Horn Strobe,UL .. . 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low 132 154 80 90 105 161 184 202 211 Max. Current Draw (mA RMS), 2-Wire Horn Strobe,UL 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output candela ratings must be reduced in accordance with 8-175 16-33 24-Volt Nominal this table. S Volts ' Volts Reverberant Anechoic StrobeOutput Listed Candela Candela rating at —40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 wit d c h S Position oun Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe SpectrAlert Advance Diagrams 119 m m IVA Wall -Mount Horn Strobes Wall Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Wall -Mount Horn Strobe with Plastic Weatherproof Back Box Red White Wall Horn Strobes P2RK P2WK 2-Wire Horn Strobe, Standard cd, Outdoor (includes plastic weatherproof back box) P2RK-P P2WK-P 2-Wire Horn Strobe, Standard cd, Outdoor, Plain (includes plastic weatherproof back box) P2RK-R P2WK-R 2-Wire Horn Strobe, Standard cd, Outdoor (does not include plastic weatherproof back box) P2RHK P2WHK 2-Wire Horn Strobe, High cd, Outdoor (includes plastic weatherproof back box) P2RHK-P P2WHK-P 2-Wire Horn Strobe, High cd, Outdoor, Plain (includes plastic weatherproof back box) P2RHK-R P2WHK-R 2-Wire Horn Strobe, High cd, Outdoor (does not include plastic weatherproof back box) P4RK P4WK 4-Wire Horn Strobe, Standard cd, Outdoor (includes plastic weatherproof back box) P4RK-R — 4-Wire Horn Strobe, Standard cd, Outdoor (does not include plastic weatherproof back box) P2RHK-120 — 2-Wire Horn Strobe, High cd, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK SWK Strobe, Standard cd, Outdoor (includes plastic weatherproof back box) SRK-P SWK-P Strobe, Standard cd, Outdoor, Plain (includes plastic weatherproof back box) SRK-R SWK-R Strobe, Standard cd, Outdoor (does not include plastic weatherproof back box) SRHK SWHK Strobe, High cd, Outdoor (includes plastic weatherproof back box) SRHK-P SWHK-P Strobe, High cd, Outdoor, Plain (includes plastic weatherproof back box) SRHK-R SWHK-R Strobe, High cd, Outdoor (does not include plastic weatherproof back box) Horns HRK — Horn, Red, Outdoor (includes plastic weatherproof back box) HRK-R — Horn, Red, Outdoor (does not include plastic weatherproof back box) Accessories SA-WBB SA-WBBW Metal Weatherproof Back Box WTP WTPW Metal Weatherproof Outdoor Flush -mounting Plate Notes: All -P models have a plain housing (no "FIRE" marking on cover). All -R models require metal weatherproof outdoor flush mounting plate or a metal weatherproof outdoor back box (order separately). "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2019System Sensor. SENSOR® Phone: 800 SENSOR2 •Fax: 630 377 6495 Product rcurre tproductinfns information, to change wtheltestive version of systemsen for current product information, including the latest version of this data sheet. www.systemsensor.com AVDS115-02.12/3/2019 ffTm! POWER PRODUCTS Rated Voltage 12V Nominal Capacity 7.OAh (C2011.75V/cell,20hrs) Length 5.95 inches ( 151 mm) Dimensions Width 2.56 inches ( 65 mm) Container Height 3.68 inches (93.5 mm) Total Height 3.92 inches (99.5 mm) Approx Weight 4.34 Ibs (1.97 Kg) Terminal F1 Container Material ABS 7.00Ah (20hr,0.350A,1.75V/cell) 6.53Ah (1 Ohr,0.653A,1.75V/cell) Rated Capacity (25°C) 5.85Ah (5hr,1.19A,1.75V/cell) 5.30 Ah (3hr,1.77A,1.75V/cell) 4.27 Ah (1 hr,4.27A,1.60V/cell) Max. Discharge Current 105A (5s) Internal Resistance (25°C) Approx 33mf0 Discharge 5 - 1220F (-15 - 50°C) Operating Temp.Range Charge -4 - 104°F (-20 - 40°C) Storage 5 - 1040F (-15 - 40°C) Nominal Operating Temp. Range 77±5°F (25±3°C) Standby/Float Use Initial Charging Current less than 2.1A. Voltage 13.5V-13.8V at 770F(25l C)Temp. Coefficient -1 OmV/o F 104°F (40°C) 103% Temperature Effect on Capacity 770F (25°C) 100% 320F ( 0°C) 86% IM series batteries may be stored for up to 6 months Self Discharge at 77°F(25°C) and then a freshening charge is required. For higher temperatures - time interval will be shorter. F.V/Time 5min 10min 15min 20min 30min 45min 1.85V/cell 17.0 12.5 9.90 8.10 6.12 4.64 1.80V/cell 18.5 13.2 10.3 8.35 6.28 4.73 1.75V/cell 19.9 13.8 10.7 8.60 6.43 4.83 1.70V/cell 21.4 14.4 11.1 8.86 6.57 4.92 1.67V/cell 22.3 14.8 11.3 9.01 6.67 4.98 1.60V/cell 24.3 15.7 11.8 9.40 6.87 5.11 C.O.V - Cutoff Voltage/cell. The battery is fully charged & being discharged to COV Constant• F.V/Time 5min 10min 15min 20min 30min 45min 1.85V/cell 32.3 23.9 19.1 15.6 11.8 9.01 1.80V/cell 34.8 25.0 19.7 16.0 12.1 9.15 1.75Wcell 37.4 26.1 20.3 16.4 12.3 9.30 1.70V/cell 39.9 27.2 20.9 16.8 12.5 9.40 1.67V/cell 41.4 27.8 21.3 17.1 12.7 9.50 1.60V/cell 44.7 29.2 22.1 17.6 13.0 9.70 C.O.V -Cutoff Voltage/cell. The battery is fully charged & being discharged to COV a I I co o. rs oo 5.94�0.0 F1 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h 3.91 2.90 2.38 1.72 1.36 1.16 0.99 0.780 0.637 0.343 3.99 2.95 2.41 1.74 1.38 1.18 1.01 0.790 0.644 0.347 4.06 3.00 2.45 1.77 1.40 1.19 1.02 0.800 0.653 0.350 4.13 3.05 2.49 1.79 1.42 1.21 1.03 0.809 0.660 0.354 4.17 3.08 2.51 1.81 1.43 1.22 1.04 0.816 0.665 0.356 4.27 3.14 2.56 1.84 1.46 1.24 1.06 0.829 0.675 0.361 1h 1.5h 2h 3h 4h 5h 6h 81h 10h 20h 7.61 5.67 4.65 3.37 2.69 2.29 1.96 1.55 1.27 0.686 7.73 5.74 4.71 3.42 2.72 2.32 1.99 1.57 1.28 0.693 7.84 5.82 4.77 3.46 2.76 2.35 2.01 1.58 1.29 0.700 7.95 5.90 4.84 3.50 2.79 2.37 2.03 1.60 1.31 0.707 8.02 5.95 4.87 3.53 2.81 2.39 2.05 1.61 1.32 0.712 8.17 6.05 4.95 3.59 2.85 2.43 2.08 1.64 1.34 0.722 O e lmm� Mi 31 P111111MIE3 PRBDUCTS Applications -All purpose • Uninterruptable Power Supply (UPS) • Electric Power System (EPS) • Emergency backup power supply -Alarm and security system • Communication power supply • DC power supply • Auto control system G= General Features Standards • 5 years design life(77oF) • Compliance with IEC 60896 standards, • Special exhaust structure and sealing technology, EU Battery Directive safe and reliable, flexible installation, convenient • UL, CE Certified maintenance • High purity PbCaSn raw material alloy is used for plate ' Manufactured in IATF16949,ISO45001, grids, assuring less gassing & low self -discharge rate ISO 9001 and ISO 14001 certified • High quality AGM separator: extend cycle life production facilities and prevent micro short circuit Discharge Characteristics MIL4 810 20 40 60 2 4 6810 20 in — H — Discharge Time Curves represent Constant Current draw ( Amp.) 1C curve= 1 x Nominal capacity= 7amp. constantdraw 0.05C curve =0.05x Nominal capacity = 0.35amp. draw Sp WN V d S Standby/Float Charge Charging Charging Volume Current Voltage (XCA) M 0.10CA-2.25V/cell Temperature77°F(25°C) 0.25 120 15 - 110 100 0.20 4- 90 80 0.15 7 13 - 60 50 0.10 12 - 40 30 0.05 20 1 0 0 ........... ..ENNE---N SIMMMMMINIM mmmmmimommi N.SA...®ENEE. I/IN'..NCO210 M 100203 0 0 4 8 12 16 20 24 28 32 36 40 Charging Time(hours) Temperature Effectes on Battery Capacity Temperature Effectes on Long Term Float Life 120 100 80 T 60 U 40 20 0.1 CA -4 14 32 50 68 86 104 122 140 -20 -10 0 10 20 30 40 50 60 Battery Temperature Sales: 1.800.233.6261 Website: www.adiglobaldistribution.us www.adiglobaldistribution.ca 5 m 4 a) T 3 0 LL 2 1 �F 0 °C 68 77 86 95 104 113 122 T 20 25 30 35 40 45 50 °C Battery Temperature Publication No.: LB-IM-1272F1-PD-ADI-V1.1-202106 e lmm� PGWER PRIBDUCTS Rated Voltage 12V Nominal Capacity 8.OAh (C2011.75V/cell,20hrs) Length 5.95 inches ( 151 mm) Dimensions Width 2.56 inches ( 65 mm) Container Height 3.68 inches (93.5 mm) Total Height 3.92 inches (99.5 mm) Approx Weight 5.03 Ibs (2.28 Kg) Terminal F1 Container Material ABS 8.00Ah (20hr,0.400A,1.75V/cell) 7.25Ah (10hr,0.725A,1.75V/cell) Rated Capacity (25°C) 6.45Ah (5hr,1.29A,1.75V/cell) 5.73 Ah (3hr,1.91 A,1.75V/cell) 4.9OAh (1 hr,4.90A,1.60V/cell) Max. Discharge Current 113A (5s) Internal Resistance (25°C) Approx 23mf0 Discharge 5 - 1220F (-15 - 50°C) Operating Temp.Range Charge -4 - 104°F (-20 - 40°C) Storage 5 - 1040F (-15 - 40°C) Nominal Operating Temp. Range 77±5°F (25±3°C) Standby/Float Use Initial Charging Current less than 2.25A. Voltage 13.5V-13.8V at 770F(25l C)Temp. Coefficient -1 OmV/o F 104°F (40°C) 103% Temperature Effect on Capacity 770F (25°C) 100% 320F ( 0°C) 86% IM series batteries may be stored for up to 6 months Self Discharge at 77°F(25°C) and then a freshening charge is required. For higher temperatures - time interval will be shorter. F.V/Time 5min 10min 15min 20min 30min 45min 1.85V/cell 24.4 16.5 12.3 10.1 7.40 5.41 1.80V/cell 26.3 17.5 12.9 10.5 7.63 5.56 1.75V/cell 27.7 18.2 13.3 10.7 7.83 5.68 1.70V/cell 29.0 18.9 13.8 11.1 8.03 5.80 1.67V/cell 30.0 19.5 14.1 11.3 8.17 5.90 1.60V/cell 31.8 20.3 14.6 11.6 8.39 6.04 C.O.V - Cutoff Voltage/cel I. The battery is fully charged & being discharged to COV F.V/Time 5min 10min 15min 20min 30min 45min 1.85V/cell 46.2 31.4 23.5 19.4 14.3 10.5 1.80V/cell 49.2 33.1 24.5 20.0 14.7 10.7 1.75V/cell 51.3 34.2 25.2 20.5 15.0 10.9 1.70V/cell 53.2 35.3 25.9 21.0 15.3 11.1 1.67V/cell 54.5 36.1 26.4 21.3 15.5 11.3 1.60V/cell 56.7 37.2 27.1 21.9 15.9 11.5 a I I co o. rs oo 5.94�0.0 F1 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h 4.43 3.25 2.57 1.85 1.48 1.26 1.08 0.848 0.708 0.391 4.54 3.31 2.62 1.88 1.50 1.27 1.09 0.860 0.718 0.395 4.63 3.37 2.66 1.91 1.52 1.29 1.11 0.869 0.725 0.400 4.72 3.43 2.70 1.94 1.54 1.31 1.12 0.878 0.732 0.403 4.79 3.48 2.73 1.96 1.55 1.32 1.13 0.885 0.738 0.406 4.90 3.55 2.79 2.00 1.58 1.34 1.14 0.898 0.747 0.411 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h 8.62 6.34 5.03 3.64 2.91 2.48 2.13 1.68 1.41 0.782 8.80 6.45 5.11 3.69 2.95 2.51 2.16 1.70 1.43 0.791 8.95 6.55 5.19 3.74 2.98 2.54 2.18 1.72 1.44 0.800 9.08 6.64 5.25 3.79 3.02 2.57 2.20 1.74 1.45 0.806 9.20 6.71 5.30 3.82 3.04 2.59 2.22 1.75 1.46 0.812 9.37 6.83 5.38 3.88 3.09 2.63 2.25 1.77 1.48 0.821 C.O.V -Cutoff Voltage/cell. The battery is fully charged & being discharged to COV O POWER PRODUCTS Applications -All purpose • Uninterruptable Power Supply (UPS) • Electric Power System (EPS) • Emergency backup power supply -Alarm and security system • Communication power supply • DC power supply • Auto control system G= General Features Standards • 5 years design life(77eF) • Compliance with IEC 60896 standards, • Special exhaust structure and sealing technology, EU Battery Directive safe and reliable, flexible installation, convenient • UL, CE Certified maintenance • High purity PbCaSn raw material alloy is used for plate ' Manufactured in IATF16949,ISO45001, grids, assuring less gassing & low self -discharge rate ISO 9001 and ISO 14001 certified • High quality AGM separator: extend cycle life production facilities and prevent micro short circuit Discharge Characteristics 01k4 810 20 40 60 2 4 6 810 20 in — H — Discharge Time Curves represent Constant Current draw ( Amp.) 1C curve= 1 x Nominal capacity= 7.5amp. constantdraw 0.05Ccurve = 0.05x Nominal capacity=0.375amp. draw Sp WN V d S Standby/Float Charge Charging Charging Volume Current Voltage (XCA) M 0.10CA-2.25V/cell Temperature77°F(25°C) 0.25 120 15 - 110 100 0.20 4- 90 80 0.15 7 13 - 60 50 0.10 12 - 40 30 0.05 20 1 0 0 ........... ..ENNE---N N.SA...®ENEE. I/IN'..NCO210 0 4 8 12 16 20 24 28 32 36 40 Charging Time(hours) Temperature Effectes on Battery Capacity Temperature Effectes on Long Term Float Life 120 100 80 T 60 U 40 20 RL 0.1 CA -4 14 32 50 68 86 104 122 140 -20 -10 0 10 20 30 40 50 60 Battery Temperature Sales: 1.800.233.6261 Website: www.adiglobaldistribution.us www.adiglobaldistribution.ua 5 m 4 a) T 3 0 LL 2 1 �F 0 °C 68 77 86 95 104 113 122 T 20 25 30 35 40 45 50 °C Battery Temperature Publication No.: LB-IM-1280F1-PD-ADI-V1.1-202106 e ffTm! POWER PRODUCTS Rated Voltage 12V Nominal Capacity 12.0Ah (C2011.75V/cell,20hrs) Length 5.95 inches (151 mm) Dimensions Width 3.86 inches( 98 mm) Container Height 3.74 inches( 95 mm) Total Height 3.98 inches (101 mm) Approx Weight 7.14 Ibs (3.24 Kg) Terminal F2 Container Material ABS 12.0Ain (20hr,0.600A,1.75V/cell) 11.2Ah (10hr,1.12A,1.75V/cell) Rated Capacity (25°C) 10.2Ain (5hr,2.04A,1.75V/cell) 9.00Ain (3hr,3.00A,1.75V/cell) 7.20 Ah (1 hr,7.20A,1.60V/cell) Max. Discharge Current 180A (5s) Internal Resistance(25°C) Approx 19mf0 Discharge 5 - 1220F (-15 - 50°C) Operating Temp.Range Charge -4 - 104°F (-20 - 40°C) Storage 5 - 1040F (-15 - 40°C) Nominal Operating Temp. Range 77±5°F (25±3°C) Standby/Float Use Initial Charging Current less than 3.6A. Voltage 13.5V-13.8V at 770F(25l C)Temp. Coefficient -10mV/o F 104°F (40°C) 103% Temperature Effect on Capacity 770F (25°C) 100% 320F ( 0°C) 86% IM series batteries may be stored for up to 6 months Self Discharge at 77°F(25°C) and then a freshening charge is required. For higher temperatures - time interval will be shorter. F.V/Time 5min 10min 15min 20min 30min 45min 1.85V/cell 30.6 22.7 18.1 14.8 11.0 8.07 1.80V/cell 33.2 23.9 18.8 15.2 11.3 8.23 1.75V/cell 35.9 25.1 19.5 15.7 11.5 8.39 1.70V/cell 38.6 26.2 20.2 16.2 11.8 8.55 1.67V/cell 40.2 26.9 20.6 16.4 12.0 8.65 1.60V/cell 43.7 28.6 21.6 17.1 12.3 8.88 C.O.V - Cutoff Voltage/cel I. The battery is fully charged & being discharged to COV F.V/Time 5min 10min 15min 20min 30min 45min 1.85V/cell 58.2 43.5 34.8 28.4 21.2 15.7 1.80V/cell 62.7 45.4 36.0 29.2 21.7 15.9 1.75V/cell 67.3 47.4 37.1 29.9 22.1 16.2 1.70V/cell 71.8 49.3 38.2 30.7 22.5 16.4 1.67V/cell 74.6 50.5 38.9 31.1 22.8 16.6 1.60V/cell 80.4 53.1 40.4 32.1 23.3 16.9 C 2 F2 5.95±0.08 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h 6.59 4.81 3.82 2.91 2.34 1.99 1.70 1.34 1.09 0.587 6.72 4.90 3.88 2.95 2.37 2.01 1.72 1.35 1.10 0.594 6.84 4.98 3.94 3.00 2.40 2.04 1.74 1.37 1.12 0.600 6.96 5.06 4.01 3.04 2.43 2.07 1.77 1.39 1.13 0.606 7.03 5.11 4.04 3.07 2.45 2.08 1.78 1.40 1.14 0.609 7.20 5.22 4.12 3.13 2.50 2.12 1.81 1.42 1.16 0.618 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h 12.8 9.40 7.49 5.72 4.60 3.92 3.36 2.65 2.17 1.17 13.0 9.53 7.58 5.79 4.66 3.97 3.40 2.68 2.19 1.19 13.2 9.66 7.68 5.87 4.72 4.02 3.44 2.71 2.22 1.20 13.4 9.79 7.78 5.94 4.77 4.06 3.48 2.74 2.24 1.21 13.5 9.87 7.84 5.98 4.80 4.09 3.50 2.76 2.26 1.22 13.8 10.0 7.97 6.08 4.88 4.15 3.56 2.80 2.29 1.24 C.O.V -Cutoff Voltage/cell. The battery is fully charged & being discharged to COV O 1111m, MY 61 POWER PRODUCTS Applications -All purpose • Uninterruptable Power Supply (UPS) • Electric Power System (EPS) • Emergency backup power supply -Alarm and security system • Communication power supply • DC power supply • Auto control system G= General Features Standards • 5 years design life(77eF) • Compliance with IEC 60896 standards, • Special exhaust structure and sealing technology, EU Battery Directive safe and reliable, flexible installation, convenient • UL, CE Certified maintenance • High purity PbCaSn raw material alloy is used for plate ' Manufactured in IATF16949,ISO45001, grids, assuring less gassing & low self -discharge rate ISO 9001 and ISO 14001 certified • High quality AGM separator: extend cycle life production facilities and prevent micro short circuit Discharge Characteristics 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 Min — M Discharge Time AM Curves represent Constant Current draw ( Amp.) 1C curve= 1 x Nominal capacity= Ramp. constantdraw 0.05Ccurve=0.05x Nominal capacity=0.60amp. draw Sp WN V d S Standby/Float Charge Charging Charging Volume Current Voltage (XCA) M 0.10CA-2.25V/cell Temperature77°F(25°C) 0.25 120 15 - 110 100 0.20 4- 90 80 0.15 7 13 - 60 50 0.10 12 - 40 30 0.05 20 1 0 0 ........... ..ENNE---N N.SA...®ENEE. I/IN'..NCO210 0 4 8 12 16 20 24 28 32 36 40 Charging Time(hours) Temperature Effectes on Battery Capacity Temperature Effectes on Long Term Float Life 120 100 80 T 60 U 40 20 0.1 CA -4 14 32 50 68 86 104 122 140 -20 -10 0 10 20 30 40 50 60 Battery Temperature Sales: 1.800.233.6261 Website: www.adiglobaldistribution.us www.adiglobaldistribution.ca 5 m 4 a) T 3 0 LL 2 1 �F 0 °C 68 77 86 95 104 113 122 T 20 25 30 35 40 45 50 °C Battery Temperature Publication No.: LB-IM-12120F2-PD-ADI-V1.1-202106 ffTm! POWER PRODUCTS Rated Voltage 12V Nominal Capacity 18.0Ah (C2011.75V/cell,20hrs) Length 7.14 inches (181.5 mm) Dimensions Width 3.01 inches ( 76.5 mm) Container Height 6.59 inches (167.5 mm) Total Height 6.59 inches (167.5 mm) Approx Weight 11.8 Ibs (5.35 Kg) Terminal F2 Container Material ABS 18.0Ah (20hr,0.900A,1.75V/cell) 17.0Ah (10hr,1.70A,1.75V/cell) Rated Capacity (25°C) 15.5Ah (5hr,3.10A,1.75V/cell) 13.8 Ah (3hr,4.59A,1.75V/cell) 11.8Ah (1 hr,11.8A,1.60V/cell) Max. Discharge Current 270A (5s) Internal Resistance (25°C) Approx 16m.0 Discharge 5 - 1220F (-15 - 50°C) Operating Temp.Range Charge -4 - 104°F (-20 - 40°C) Storage 5 - 1040F (-15 - 40°C) Nominal Operating Temp. Range 77±5°F (25±3°C) Standby/Float Use Initial Charging Current less than 5.4A. Voltage 13.5V-13.8V at 770F(25l C)Temp. Coefficient -10mV/o F 104°F (40°C) 103% Temperature Effect on Capacity 770F (25°C) 100% 320F ( 0°C) 86% IM series batteries may be stored for up to 6 months Self Discharge at 77°F(25°C) and then a freshening charge is required. For higher temperatures - time interval will be shorter. F.V/Time 5min 10min 15min 20min 30min 45min 1.85V/cell 54.7 37.5 29.2 24.0 17.9 13.1 1.80V/cell 58.9 39.8 30.6 25.0 18.4 13.4 1.75V/cell 62.0 41.4 31.7 25.7 18.9 13.7 1.70V/cell 64.9 43.0 32.7 26.4 19.4 14.0 1.67V/cell 67.2 44.2 33.5 27.0 19.7 14.2 1.60V/cell 71.3 46.1 34.7 27.8 20.3 14.6 C.O.V - Cutoff Voltage/cell. The battery is fully charged & being discharged to COV Constant• F.V/Time 5min 10min 15min 20min 30min 45min 1.85V/cell 103.5 71.4 55.9 46.3 34.6 25.4 1.80V/cell 110.3 75.2 58.3 47.9 35.5 25.9 1.75V/cell 114.9 77.6 59.9 48.9 36.2 26.4 1.70V/cell 119.2 80.2 61.5 50.1 37.0 26.9 1.67V/cell 122.3 82.0 62.8 51.0 37.5 27.3 1.60V/cell 127.2 84.4 64.5 52.3 38.4 27.8 25 7.14:0.08 F2 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h 10.7 7.84 6.16 4.45 3.54 3.02 2.58 2.03 1.66 0.880 11.0 8.00 6.28 4.52 3.59 3.06 2.62 2.06 1.69 0.890 11.2 8.15 6.39 4.59 3.64 3.10 2.65 2.09 1.70 0.900 11.4 8.29 6.48 4.66 3.69 3.14 2.68 2.11 1.72 0.907 11.6 8.40 6.56 4.70 3.73 3.17 2.71 2.12 1.73 0.914 11.8 8.58 6.69 4.79 3.79 3.22 2.75 2.15 1.75 0.924 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h 20.8 15.3 12.1 8.74 6.98 5.95 5.11 4.03 3.31 1.76 21.3 15.6 12.3 8.87 7.07 6.03 5.18 4.09 3.35 1.78 21.6 15.8 12.4 8.98 7.16 6.10 5.23 4.13 3.38 1.80 21.9 16.1 12.6 9.10 7.24 6.17 5.29 4.17 3.41 1.81 22.2 16.2 12.7 9.18 7.30 6.22 5.33 4.20 3.43 1.83 22.6 16.5 12.9 9.32 7.41 6.30 5.40 4.25 3.47 1.85 C.O.V -Cutoff Voltage/cell. The battery is fully charged & being discharged to COV O e lmm� Mi 31 P111111MIE3 PRBDUCTS Applications -All purpose • Uninterruptable Power Supply (UPS) • Electric Power System (EPS) • Emergency backup power supply -Alarm and security system • Communication power supply • DC power supply • Auto control system G= General Features Standards • 5 years design life(77eF) • Compliance with IEC 60896 standards, • Special exhaust structure and sealing technology, EU Battery Directive safe and reliable, flexible installation, convenient • UL, CE Certified maintenance • High purity PbCaSn raw material alloy is used for plate ' Manufactured in IATF16949,ISO45001, grids, assuring less gassing & low self -discharge rate ISO 9001 and ISO 14001 certified • High quality AGM separator: extend cycle life production facilities and prevent micro short circuit Discharge Characteristics E&k81020 40 60 2 4 6 8 10 20 Min — H Discharge Time Curves represent Constant Current draw ( Amp.) 1C curve= 1 x Nominal capacity=18amp. constant draw 0.05C curve=0.05x Nominal capacity=0.90amp. draw Sp WN V d S Standby/Float Charge Charging Charging Volume Current Voltage (XCA) M 0.10CA-2.25V/cell Ternperature77°F(25°C) 0.25 120 15 - 110 100 0.20 4- 90 80 0.15 7 13 - 60 50 0.10 12, 40 30 0.05 20 1 0 0 ........... ..ENNE---N SIMMMMMINIM mmmmmimm N.SA...®ENEE. I/IN'..NCO210 MEN'0020300 0 4 8 12 16 20 24 28 32 36 40 Charging Time(hours) Temperature Effectes on Battery Capacity Temperature Effectes on Long Term Float Life 120 100 80 T 60 0 40 20 RL 0.1 CA -4 14 32 50 68 86 104 122 140 -20 -10 0 10 20 30 40 50 60 Battery Temperature Sales: 1.800.233.6261 Website: www.adiglobaldistribution.us www.adiglobaldistribution.ua 5 m 4 a) T 3 0 LL 2 1 �F 0 °C 68 77 86 95 104 113 122 T 20 25 30 35 40 45 50 °C Battery Temperature Publication No.: LB-IM-12180F2-PD-ADI-V1.1-202106 lurmlIgH-11F,"' P1111MIE11111 PAGBUCTi Rated Voltage Nominal Capacity Dimensions Approx Weight Terminal Container Material Rated Capacity (25°C) Max. Discharge Current Internal Resistance (25°C) Operating Temp.Range Nominal Operating Temp. Range Standby/Float Use Temperature Effect on Capacity Self Discharge 12V 26.OAh (C2011.75V/cell,20hrs) Length 6.56 inches (166 mm) Width 6.89 inches (175 mm) Container Height 4.92 inches (125 mm) Total Height 4.92 inches (125 mm) 17.2 Ibs (7.8 Kg) F2 ABS 26.0 Ah (20hr,1.30A,1.75V/cell ) 23.5 Ah (1 Ohr,2.35A,1.75V/cell) 20.7 Ah (5hr,4.13A,1.75V/cel1) 18.9Ah (3hr,6.31A,1.75V/ce11) 15.4 Ah (1 hr,15.4A,1.60V/cell) 360A (5s) Approx 16mQ Discharge 5 - 1220F (-15 - 50°C) Charge -4 - 104°F (-20 - WC) Storage 5 - 1040F (-15 - 40°C) 77±5°F (25±3°C) Initial Charging Current less than 7.2A. Voltage 13.5V-13.8V at 770F(25° C)Temp. Coefficient-10mV/° F 104°F (40°C) 103% 770F (25°C) 100% 320F ( 0°C) 86% IM series batteries may be stored for up to 6 months at 77°F(25°C) and then a freshening charge is required. For higher temperatures - time interval will be shorter. I I o v I I v I I I I m I I -t} °=°3 I F2 ® i 6.89t0.08 F.V/Time 5min 10min 15min 20min 30min 45min 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 60.2 41.6 32.9 26.9 20.2 15.0 12.7 9.48 7.59 5.68 4.50 3.75 3.22 2.56 2.16 1.21 1.80V/cell 70.2 49.0 38.3 31.0 22.9 16.8 14.0 10.4 8.26 6.15 4.85 4.04 3.46 2.74 2.31 1.28 1.75V/cell 76.6 52.6 40.5 32.5 23.9 17.4 14.6 10.7 8.51 6.31 4.97 4.13 3.53 2.79 2.35 1.30 1.70V/cell 83.0 56.1 42.8 34.2 24.9 18.1 15.1 11.1 8.78 6.50 5.09 4.22 3.60 2.84 2.38 1.31 1.67V/cell 86.7 58.1 44.1 35.2 25.6 18.5 15.4 11.3 8.93 6.59 5.16 4.27 3.65 2.86 2.40 1.32 1.60V/cell 95.5 62.9 47.3 37.4 27.0 19.5 16.2 11.8 9.30 6.84 5.34 4.41 3.75 2.93 2.45 1.34 C.O.V -Cutoff Voltage/cel I. The battery is fully charged & being discharged to C OV Constant• • r r F.V/Time 5min 10min 15min 20min 30min 45min 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 114.8 79.6 63.2 51.8 39.1 29.1 24.7 18.5 14.8 11.1 8.84 7.38 6.35 5.05 4.28 2.40 1.80V/cell 132.1 92.9 72.8 59.1 43.8 32.3 27.1 20.1 16.1 12.0 9.49 7.92 6.80 5.40 4.56 2.53 1.75V/cell 142.3 98.5 76.2 61.4 45.4 33.3 27.9 20.7 16.5 12.3 9.70 8.08 6.92 5.48 4.63 2.56 1.70V/cell 152.1 103.8 79.7 64.0 47.0 34.3 28.7 21.2 16.9 12.6 9.90 8.24 7.05 5.57 4.69 2.59 1.67V/cell 157.4 106.8 82.3 65.4 47.9 34.9 29.2 21.5 17.1 12.7 10.0 8.32 7.12 5.62 4.73 2.61 1.60V/cell 171.5 114.3 86.2 68.7 50.0 36.3 30.3 22.3 17.7 13.1 10.3 8.54 7.29 5.73 4.81 2.66 C.O.V -Cutoff Voltage/cell. The battery is fully charged & being discharged to COV O e ffffM 14H PGWEN PROMUCTi Applications -All purpose • Uninterruptable Power Supply (UPS) • Electric Power System (EPS) • Emergency backup power supply • Alarm and security system • Communication power supply • DC power supply • Auto control system r3 General Features Standards • 5 years design life(77eF) • Compliance with IEC 60896 standards, • Special exhaust structure and sealing technology, EU Battery Directive safe and reliable, flexible installation, convenient • UL, CE Certified maintenance • High purity PbCaSn raw material alloy is used for plate ' Manufactured in IATF16949,ISO45001, grids, assuring less gassing & low self -discharge rate ISO 9001 and ISO 14001 certified • High quality AGM separator: extend cycle life production facilities and prevent micro short circuit Discharge Characteristics MM6M8 10 20 40 602 4 6 8 10 20 in — H Discharge Time Curves represent Constant Current draw ( Amp.) 1C curve= 1 x Nominal capacity=24amp. constant draw 0.05C curve=0.05 x Nominal capacity=1.20amp. draw W ® 1LJ VdS Standby/Float Charge Charging Charging Volume Current Voltage (XCA) M 0.10CA-2.25V/cell Ternperature77°F(25°C) 0.25 120 15 - 110 100 0.20 4- 90 80 0.15- 70- 13- 60 50 0.10 12 - 40 30 0.05 20 1 0 0 ........... ..ENNE---N §Iffin �-IIIIII,IIIIII,IIIIII,IIIIIl��� N.SA...®ENEE. 0 4 8 12 16 20 24 28 32 36 40 Charging Time(hours) Temperature Effectes on Battery Capacity Temperature Effectes on Long Term Float Life 120 100 80 T 60 U 40 20 RL 0.1 CA -4 14 32 50 68 86 104 122 140 -20 -10 0 10 20 30 40 50 60 Battery Temperature Sales: 1.800.233.6261 Website: www.adiglobaldistribution.us www.adiglobaldistribution.ca 5 m 4 a) T 3 0 LL 2 1 �F 0 °C 68 77 86 95 104 113 122 T 20 25 30 35 40 45 50 °C Battery Temperature Publication No.: LB-IM-12260F2-PD-ADI-V1.1-202106 Y,9 ffJ17 114 H -1 P11111w13 P886UCTi Rated Voltage 12V Nominal Capacity 26.OAh (C2011.75V/cell,20hrs) Length 6.56 inches (166 mm) Dimensions Width 6.89 inches (175 mm) Container Height 4.92 inches (125 mm) Total Height 4.92 inches (125 mm) Approx Weight 17.2 Ibs (7.8 Kg) Terminal NB 2 Container Material ABS 26.0 Ah (20hr,1.30A,1.75V/cell ) 23.5 Ah (1 Ohr,2.35A,1.75V/cell) Rated Capacity (25°C) 20.7Ah (5hr,4.13A,1.75V/cel1) 18.9Ah (3hr,6.31A,1.75V/ce11) 15.4 Ah (1 hr,15.4A,1.60V/cell) Max. Discharge Current 360A (5s) Internal Resistance (25°C) Approx 16m.0 Discharge 5 - 1220F (-15 - 50°C) Operating Temp.Range Charge -4 - 104°F (-20 - WC) Storage 5 - 1040F (-15 - 400C) Nominal Operating Temp. Range 77±5°F (25±3°C) Standby/Float Use Initial Charging Current less than 7.2A. Voltage 13.5V-13.8V at 770F(25lC)Temp. Coefficient -10mV/o F 104°F (40°C) 103% Temperature Effect on Capacity 770F (25°C) 100% 320F ( 0°C) 86% IM series batteries may be stored for up to 6 months Self Discharge at 77°F(25°C) and then a freshening charge is required. For higher temperatures - time interval will be shorter. ma i F.V/Time 5min 10min 15min 20min 30min 45min 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 60.2 41.6 32.9 26.9 20.2 15.0 12.7 9.48 7.59 5.68 4.50 3.75 3.22 2.56 2.16 1.21 1.80V/cell 70.2 49.0 38.3 31.0 22.9 16.8 14.0 10.4 8.26 6.15 4.85 4.04 3.46 2.74 2.31 1.28 1.75V/cell 76.6 52.6 40.5 32.5 23.9 17.4 14.6 10.7 8.51 6.31 4.97 4.13 3.53 2.79 2.35 1.30 1.70V/cell 83.0 56.1 42.8 34.2 24.9 18.1 15.1 11.1 8.78 6.50 5.09 4.22 3.60 2.84 2.38 1.31 1.67V/cell 86.7 58.1 44.1 35.2 25.6 18.5 15.4 11.3 8.93 6.59 5.16 4.27 3.65 2.86 2.40 1.32 1.60V/cell 95.5 62.9 47.3 37.4 27.0 19.5 16.2 11.8 9.30 6.84 5.34 4.41 3.75 2.93 2.45 1.34 C.O.V - Cutoff Voltage/cel I. The battery is fully charged & being discharged to C OV Constant• • r r F.V/Time 5min 10min 15min 20min 30min 45min 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 114.8 79.6 63.2 51.8 39.1 29.1 24.7 18.5 14.8 11.1 8.84 7.38 6.35 5.05 4.28 2.40 1.80V/cell 132.1 92.9 72.8 59.1 43.8 32.3 27.1 20.1 16.1 12.0 9.49 7.92 6.80 5.40 4.56 2.53 1.75V/cell 142.3 98.5 76.2 61.4 45.4 33.3 27.9 20.7 16.5 12.3 9.70 8.08 6.92 5.48 4.63 2.56 1.70V/cell 152.1 103.8 79.7 64.0 47.0 34.3 28.7 21.2 16.9 12.6 9.90 8.24 7.05 5.57 4.69 2.59 1.67V/cell 157.4 106.8 82.3 65.4 47.9 34.9 29.2 21.5 17.1 12.7 10.0 8.32 7.12 5.62 4.73 2.61 1.60V/cell 171.5 114.3 86.2 68.7 50.0 36.3 30.3 22.3 17.7 13.1 10.3 8.54 7.29 5.73 4.81 2.66 C.O.V - Cutoff Voltage/cell. The battery is fully charged & being discharged to COV r 0.551 0.0ry79 � o 0 a NB 2 O e ffffM 14H PGWE• PII111111OIICTi Applications -All purpose • Uninterruptable Power Supply (UPS) • Electric Power System (EPS) • Emergency backup power supply • Alarm and security system • Communication power supply • DC power supply • Auto control system r3 General Features Standards • 5 years design life(77eF) • Compliance with IEC 60896 standards, • Special exhaust structure and sealing technology, EU Battery Directive safe and reliable, flexible installation, convenient • UL, CE Certified maintenance • High purity PbCaSn raw material alloy is used for plate ' Manufactured in IATF16949,ISO45001, grids, assuring less gassing & low self -discharge rate ISO 9001 and ISO 14001 certified • High quality AGM separator: extend cycle life production facilities and prevent micro short circuit Discharge Characteristics MM6M8 10 20 40 602 4 6 8 10 20 in — H Discharge Time Curves represent Constant Current draw ( Amp.) 1C curve= 1 x Nominal capacity=24amp. constant draw 0.05C curve=0.05 x Nominal capacity=1.20amp. draw W ® 1LJ VdS Standby/Float Charge Charging Charging Volume Current Voltage (XCA) M 0.10CA-2.25V/cell Ternperature77°F(25°C) 0.25 120 15 - 110 100 0.20 4- 90 80 0.15- 70- 13- 60 50 0.10 12 - 40 30 0.05 20 1 0 0 ........... ..ENNE---N §Iffin �-IIIIII,IIIIII,IIIIII,IIIIIl��� N.SA...®ENEE. 0 4 8 12 16 20 24 28 32 36 40 Charging Time(hours) Temperature Effectes on Battery Capacity Temperature Effectes on Long Term Float Life 120 100 80 T 60 U 40 20 RL 0.1 CA -4 14 32 50 68 86 104 122 140 -20 -10 0 10 20 30 40 50 60 Battery Temperature Sales: 1.800.233.6261 Website: www.adiglobaldistribution.us www.adig oba distribution.ca 5 m 4 a) T 3 0 LL 2 1 �F 0 °C 68 77 86 95 104 113 122 T 20 25 30 35 40 45 50 °C Battery Temperature Publication No.: LB-IM-12260NB-PD-ADI-V1.1-202106 e fflm� PGWEB PRIBDUCTS Rated Voltage 12V Nominal Capacity 35.OAh (C2011.75V/cell,20hrs) Length 7.68 inches (195mm) Dimensions Width 5.12 inches (130mm) Container Height 6.46 inches (164mm) Total Height 7.01 inches (178mm) Approx Weight 23.6 Ibs (10.7 Kg) Terminal NB 3 Container Material ABS 35.0 Ah (20hr,1.75A,1.75V/cell) 33.1 Ah (1 Ohr,3.31A,1.75V/cell) Rated Capacity (25°C) 30.1 Ah (5hr,6.02A,1.75V/cell) 27.1 Ah (3hr,9.03A,1.75V/cell) 23.8Ah (1 hr,23.8A,1.60V/cell) Max. Discharge Current 525A (5s) Internal Resistance (25°C) Approx 10mQ Discharge 5 - 1220F (-15 - 50°C) Operating Temp.Range Charge -4 - 104°F (-20 - 40°C) Storage 5 - 1040F (-15 - 40°C) Nominal Operating Temp. Range 77±5°F (25±3°C) Standby/Float Use Initial Charging Current less than 10.5A. Voltage 13.5V-13.8V at 770F(25lC)Temp. Coefficient -1 OmV/o F 104°F (40°C) 103% Temperature Effect on Capacity 770F (25°C) 100% 320F ( 0°C) 86% IM series batteries may be stored for up to 6 months Self Discharge at 77°F(25°C) and then a freshening charge is required. For higher temperatures - time interval will be shorter. F.V/Time 5min 10min 15min 20min 30min 45min 1.85V/cell 114.4 78.5 60.4 48.8 36.0 26.3 1.80V/cell 123.1 83.2 63.4 50.8 37.1 27.0 1.75V/cell 129.7 86.5 65.5 52.2 38.0 27.6 1.70V/cell 135.8 90.0 67.7 53.7 39.0 28.2 1.67V/cell 140.5 92.5 69.3 54.8 39.7 28.6 1.60V/cell 149.0 96.4 71.7 56.5 40.8 29.4 C.O.V - Cutoff Voltage/cel I. The battery is fully charged & being discharged to COV Constant• F.V/Time 5min 10min 15min 20min 30min 45min 1.85V/cell 216.5 149.3 115.6 94.1 69.5 51.0 1.80V/cell 230.6 157.2 120.6 97.3 71.3 52.2 1.75V/cell 240.3 162.3 123.8 99.5 72.9 53.1 1.70V/cell 249.2 167.7 127.2 101.8 74.4 54.1 1.67V/cell 255.7 171.4 130.0 103.7 75.5 54.8 1.60V/cell 266.0 176.4 133.5 106.3 77.2 55.8 C.O.V -Cutoff Voltage/cell. The battery is fully charged & being discharged to COV 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h 21.5 15.7 12.3 8.74 6.89 5.86 5.02 3.96 3.23 1.71 22.1 16.0 12.5 8.89 6.99 5.95 5.10 4.01 3.28 1.73 22.5 16.3 12.7 9.03 7.08 6.02 5.16 4.06 3.31 1.75 22.9 16.6 12.9 9.16 7.18 6.11 5.22 4.10 3.34 1.76 23.3 16.8 13.0 9.25 7.25 6.16 5.27 4.13 3.37 1.78 23.8 17.2 13.3 9.42 7.38 6.26 5.34 4.19 3.41 1.80 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h 41.9 30.6 24.0 17.2 13.6 11.6 9.93 7.84 6.43 3.42 42.8 31.2 24.4 17.4 13.7 11.7 10.1 7.95 6.51 3.46 43.5 31.6 24.8 17.7 13.9 11.9 10.2 8.03 6.57 3.50 44.1 32.1 25.1 17.9 14.1 12.0 10.3 8.10 6.63 3.53 44.7 32.4 25.3 18.0 14.2 12.1 10.4 8.16 6.68 3.56 45.5 33.0 25.7 18.3 14.4 12.3 10.5 8.27 6.75 3.59 O POMIER PRODUCTS Applications -All purpose • Uninterruptable Power Supply (UPS) • Electric Power System (EPS) • Emergency backup power supply -Alarm and security system • Communication power supply • DC power supply • Auto control system r:1 General Features Standards • 5 years design life(77eF) • Compliance with IEC 60896 standards, • Special exhaust structure and sealing technology, EU Battery Directive safe and reliable, flexible installation, convenient • UL, CE Certified maintenance • High purity PbCaSn raw material alloy is used for plate ' Manufactured in IATF16949,ISO45001, grids, assuring less gassing & low self -discharge rate ISO 9001 and ISO 14001 certified • High quality AGM separator: extend cycle life production facilities and prevent micro short circuit Discharge Characteristics 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 Min — M Discharge Time AM Curves represent Constant Current draw ( Amp.) 1C curve= 1 x Nominal capacity=35amp. constantdraw 0.05C curve =0.05x Nominal capacity=1.75amp. draw Sp WN V d S Standby/Float Charge Charging Charging Volume Current Voltage (XCA) M 0.10CA-2.25V/cell Temperature77°F(25°C) 0.25 120 15 - 110 100 0.20 4- 90 80 0.15 7 13 - 60 50 0.10 12 - 40 30 0.05 20 1 0 0 ........... ..ENNE---N N.SA...®ENEE. I/IN'..NCO210 0 4 8 12 16 20 24 28 32 36 40 Charging Time(hours) Temperature Effectes on Battery Capacity Temperature Effectes on Long Term Float Life 120 100 80 T 60 N U 40 20 RL 0.1 CA -4 14 32 50 68 86 104 122 140 -20 -10 0 10 20 30 40 50 60 Battery Temperature Sales: 1.800.233.6261 Website: www.adiglobaldistribution.us www.adiglobaldistribution.ua 5 m 4 a) T d 3 m LL 2 1 �F 0 °C 68 77 86 95 104 113 122 T 20 25 30 35 40 45 50 °C Battery Temperature Publication No.: LB-IM-12350NB-PD-ADI-V1.1-202106 Y's ffffM 114 H -I PIWEI PROBUCTi Rated Voltage 12V Nominal Capacity 75.OAh (C2011.75V/cell,20hrs) Length 10.2 inches (260mm) Dimensions Width 6.61 inches (168mm) Container Height 8.19 inches (208mm) Total Height 9.06 inches (230mm) Approx Weight 50.05 Ibs (22.7 Kg) Terminal U Container Material ABS 75.0 Ah (20hr, 3.75A,1.75V/cell ) 73.7 Ah (1 Ohr,7.37A,1.75V/cell) Rated Capacity (25°C) 67.5Ah (5hr,13.5A,1.75V/cel1) 61.5Ah 47.3Ah (3hr,20.5A,1.75V/ce11) (1hr,47.3A,1.60V/cel1) Max. Discharge Current 750A (5s) Internal Resistance (25°C) Approx 7.5m4 Discharge 5 - 1220F (-15 - 50°C) Operating Temp.Range Charge -4 - 104°F (-20 - 40°C) Storage 5 - 1040F (-15 - 40°C) Nominal Operating Temp. Range 77±5°F (25±3°C) Standby/Float Use Initial Charging Current less than 22.5A. Voltage 13.5V-13.8V at 770F(25lC)Temp. Coefficient -1 OmV/o F 104°F (40°C) 103% Temperature Effect on Capacity 770F (25°C) 100% 320F ( 0°C) 86% IM series batteries may be stored for up to 6 months Self Discharge at 77°F(25°C) and then a freshening charge is required. For higher temperatures - time interval will be shorter. F.V/Time 10min 15min 20min 30min 451min 1.85V/cell 109.8 95.2 74.9 67.0 49.0 1.80V/cell 124.7 107.9 84.7 72.9 51.9 1.75V/cell 135.2 116.8 91.4 74.4 53.8 1.70V/cell 144.2 124.1 96.9 75.9 54.8 1.65V/cell 148.7 127.7 99.6 77.0 55.6 1.60V/cell 153.8 131.7 102.1 78.1 56.4 C.O.V - Cutoff Voltage/cell. The battery is fully charged & being discharged to COV Constant• F.V/Time 10min 15min 20min 30min 45min 1.85V/cell 206.7 180.3 142.5 128.0 94.2 1.80V/cell 231.2 201.7 159.4 138.2 99.1 1.75V/cell 246.7 215.3 170.1 140.0 102.1 1.70V/cell 259.4 226.3 178.8 141.6 103.4 1.65Wcell 263.6 230.0 181.7 142.6 104.3 1.60V/cell 267.3 233.2 184.2 143.2 104.8 C.O.V - Cutoff Voltage/cell. The battery is fully charged & being discharged to COV 8.z7 f 0.2±0.os 1h 2h 3h 4h 5h 6h 8h 10h 20h 41.5 25.3 18.5 14.5 12.6 11.1 8.56 6.95 3.57 43.0 26.1 20.1 15.5 13.3 12.0 9.00 7.35 3.71 45.1 27.5 20.5 15.8 13.5 12.0 9.05 7.37 3.75 46.0 28.0 20.9 16.1 13.7 12.1 9.19 7.42 3.78 46.7 28.4 21.1 16.3 14.0 12.2 9.32 7.52 3.83 47.3 28.8 21.3 16.5 14.2 12.2 9.44 7.60 3.87 1h 2h 3h 4h 5h 6h 8h 10h 20h 80.2 49.2 36.2 28.5 24.9 22.0 17.0 13.8 7.12 82.6 50.5 39.1 30.3 26.0 23.5 17.8 14.4 7.36 86.3 53.0 39.8 30.8 26.4 23.6 17.9 14.6 7.43 87.6 53.8 40.4 31.2 26.8 23.7 18.1 14.7 7.50 88.4 54.4 40.6 31.6 27.2 23.8 18.3 14.9 7.58 89.0 54.8 40.8 31.8 27.5 23.7 18.5 15.0 7.66 O Y's ffffM 11 a H -I PGWE■ PRI111116UCTi Applications -All purpose • Uninterruptable Power Supply (UPS) • Electric Power System (EPS) • Emergency backup power supply • Alarm and security system • Communication power supply • DC power supply • Auto control system r3 General Features Standards • 5 years design life(77eF) • Compliance with IEC 60896 standards, • Special exhaust structure and sealing technology, EU Battery Directive safe and reliable, flexible installation, convenient • UL, CE Certified maintenance • High purity PbCaSn raw material alloy is used for plate ' Manufactured in IATF16949,ISO45001, grids, assuring less gassing & low self -discharge rate ISO 9001 and ISO 14001 certified • High quality AGM separator: extend cycle life production facilities and prevent micro short circuit Discharge Characteristics MM6M8 10 20 40 602 4 6 8 10 20 in — H Discharge Time Curves represent Constant Current draw ( Amp.) 1C curve= 1 x Nominal capacity=75amp. constant draw 0.05C curve=0.05 x Nominal capacity=3.75amp. draw W ® 1LJ VdS Standby/Float Charge Charging Charging Volume Current Voltage (XCA) M 0.10CA-2.25V/cell Ternperature77°F(25°C) 0.25 120 15 - 110 100 0.20 4- 90 80 0.15- 70- 13- 60 50 0.10 12 - 40 30 0.05 20 1 0 0 ........... ..ENNE---N §Iffin �-IIIIII,IIIIII,IIIIII,IIIIIl��� N.SA...®ENEE. 0 4 8 12 16 20 24 28 32 36 40 Charging Time(hours) Temperature Effectes on Battery Capacity Temperature Effectes on Long Term Float Life 120 100 80 T 60 U 40 20 RL 0.1 CA -4 14 32 50 68 86 104 122 140 -20 -10 0 10 20 30 40 50 60 Battery Temperature Sales: 1.800.233.6261 Website: www.adiglobaldistribution.us www.adiglobaldistribution.ua 5 m 4 a) T 3 0 LL 2 1 �F 0 °C 68 77 86 95 104 113 122 T 20 25 30 35 40 45 50 °C Battery Temperature Publication No.: LB-IM-12750U-PD-ADI-V1.1-202106