APPROVED BLD BLD2024-0809+Architectural_Plan+6.18.2024_1.15.54_PM+4329845EXIST PIPING
SIMPSON LUS
HANGER, TYP
3 MAX
TYP
aL
LL LL
0 0
x x
" -
F-
SISTER NEW JOIST TO
J
L J
L
—
EXIST W/ (2) ROWS 16d
NAILS @ 12" OC IN
STAGGERED ROWS, TYP
2'-10"±
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
BATHROOM
13'-11"±
EXIST 2x10 @ 16" OC
FLOOR JOIST
2x10 HF#2
2x10 HF#2
UNIT D101 PARTIAL FLOOR PLAN
0
x
N
X
LLJ
SCALE: 1/4" = V-0"
NOTE:
1. CONTRACTOR FIELD VERIFY FLOOR PLAN ABOVE MATCHES UNIT D101 FLOOR PLAN.
NOTIFY ENGINEER IF CONDITIONS DIFFER FOR POSSIBLE REDESIGN.
--------------
Fire rated
assemblies are to i
i maintained and any i
new construction
shall meet the
minimum i
I requirements as the i
i original construction.
i OBTAIN A SEPARATE
PLUMBING PERMIT
FROM THE CITY OF
EDMONDS.
City Of Edmonds
Building Department
--- ----
Work ; REPAIR FLOOR JOISTS
--------------------------------------
Address 8615 238TH ST SW D101
-----------------:---
Owner:N
--------------------
Approved Date: 4/02/2024
Building Official ---------------
Permit Number:
BLD2024-0809
RECEIVED
6/18/24
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
0611,5124
C
ENGINEERING
PARK PLACE CONDOMINIMUMS
8615 238TH ST SW UNIT D101
EDMONDS, WA 98026
DATE 06/18/24
SHEET
PROJECT NO. 24142.10
SCALE 1/4" - V-0••
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
TITLE
STRUCTURAL DETAILS
DRAWN BY JEC
S K -1
CHECKED BY LMS
APPROVED BY DMT