APPROVED BLD BLD2024-1226+Architectural Plan+9.12.2024_1.34.03_PM+4496896TINGSTAD RES DENCE, DRY ROT REPAIR 533 ALDER ST, UNIT Al EDMONDS, WA 98020 OWNER ANDREW TINGSTAD 533 ALDER ST, UNIT Al EDMONDS, WA 98020 LEGAL DESCRIPTION CONSULTANTS STRUCTURAL ENGINEER CG ENGINEERING 250 4TH AVE S, SUITE 200 EDMONDS, WA 98020 425.778.8500 FAX 778.5536 CONTACT: MIKE MAECHLER, PE, SE UNIT 1, BUILDING A, THE MARINER, A CONDOMINIUM, ACCORDING TO THE DECLARATION THEREOF, RECORDED UNDER SNOHOMISH COUNTY RECORDING NO. 2336723, AND ANY AMENDMENTS THERETO, SAID UNIT IS LOCATED ON SURVEY MAP AND PLANS FILED IN VOLUME 34 OF CONDOMINIUMS, PAGES 71 THROUGH 72, INCLUSIVE, AND ANY AMENDMENTS THERETO. SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. PARCEL NUMBER 00639900100100 PROPERTY INFORMATION TOTAL LOT AREA = 25,400 SQFT EX BUILDING FOOTPRINT = 9,240 SQFT PROPOSED BUILDING FOOTPRINT = NOT TO CHANGE TOTAL IMPERVIOUS SURFACE = NOT TO CHANGE SCOPE OF WORK REPAIR EXISTING ROTTED BEAM AT EXISTING CONDO. NOTE: SITE PLAN HAS BEEN PREPARED BASED ON FIELD MEASUREMENTS & COUNTY RECORDS & IS NOT A SURVEY, PROPERTY LINES ARE APPROXIMATE. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS & UTILITY LOCATIONS. Fire rated assemblies shall be maintained or restored to match or exceed existing conditions. City Of Edmonds Building Department Work DRY ROT/FRAMING REPAIRS Address 533 ALDER ST A-1 - L......................................................................................................... Owner TINGSTAD ..............................-................................................................... Approved Date Building Official Permit Number 09/24/202'4............................................... ...................................... ------------------------------------- ..__..__..__..__..__..__.............................................. cl-- ............................................ BLD2024-1226 EXISTING SIDEWALK EXISTING DRIVEWAY SITE ALL WORK SUBJECT "— = 0 TO FIELD INSPECTION FOR CODE COMPLIANCE ALDER ST APPROVED PLANS MUST BE ON JOB SITE Dayton St Dayton St Dayton St Dayton St Dayton St D N 7 < eD Q < N s N Maple St D W _A n Alder St D < =r D < � N N D A N o� Beck Ln D Bec, N Walnut St Walnut St Kelso Ct °' Q. D �^ Holly Dr er Cek C D ghellabar9re D m fn N Howell Way VICINITY MAP NTS = PROJECT SITE 10 0 5 10 16 20 C G ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 wOF WAS$ IONAL 011 09/06/24 DESIGN: BTJ DRAWN: JOS CHECK: MTM JOB NO: 24296.10 DATE: 09/06/24 RECEIVED Sep 19 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT a z Q W I- N z Z O WD00 o � V z w p Ld (n F 0 o Q z O W z M o Low () � SHEET: S001 STRUCTURAL NOTES (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) CODE GENERAL ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL, AND SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2021 EDITION. SPECIFICATIONS AND STANDARDS MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. DESIGN LOADS CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION DEAD LOADS: OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. ROOF 15 PSF FLOOR 41 PSF CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. LIVE LOADS: ROOF (SNOW LOAD) 25 PSF RESIDENTIAL 40 PSF STATEMENT OF SPECIAL INSPECTIONS SPECIAL INSPECTIONS ARE NOT REQUIRED. SHOP DRAWINGS SHOP DRAWINGS ARE NOT REQUIRED. STRUCTURAL STEEL STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE AISC "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS", LATEST EDITION. WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992, Fy = 50 KSI. PLATES, ANGLES, CHANNELS, AND RODS SHALL CONFORM TO ASTM A36, Fy = 36 KSI. STRUCTURAL TUBING SHALL CONFORM TO ASTM A500 GRADE C, RECTANGULAR/SQUARE Fy = 50 KSI, ROUND Fy = 46 KSI. STEEL PIPE SHALL CONFORM TO ASTM A53 GRADE B, Fy = 35 KSI. BOLTS CONNECTING STEEL MEMBERS SHALL CONFORM TO ASTM A325-N. BOLTS SHALL BE 3/4"0 MINIMUM, UNO ANCHOR BOLTS SHALL CONFORM TO ASTM A307. CONTRACTOR SHALL PROVIDE CONNECTION ADJUSTMENT TOLERANCES TO SATISFY THE REQUIREMENTS OF AISC MANUAL OF STEEL CONSTRUCTION. UNLESS SPECIFIED AS STAINLESS STEEL, ALL STEEL MEMBERS, SHAPES, BOLTS, AND ACCESSORIES EXPOSED TO WEATHER SHALL BE HOT DIP GALVANIZED. LUMBER ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: SIZE CLASSIFICATION SPECIES GRADE Fb (PSI) Fc (PSI) SLEEPERS DOUG-FIR STUD 700 - LIGHT FRAMING (STUDS) HEM -FIR STUD 675 800 2x JOISTS AND PLANKS HEM -FIR #2 850 - PLATES AND BLOCKING HEM -FIR #2 850 - 6x AND LARGER BEAMS AND STRINGERS DOUG-FIR #2 875 - 4x AND SMALLER BEAMS AND STRINGERS HEM -FIR #2 850 - ALL POSTS AND TIMBERS DOUG-FIR #1 1200 1000 REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1. NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1 NAILING SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: NAIL SHANK 0 MIN LENGTH 8d COMMON 0.1310 2 1/2" SHANK 10d COMMON 0.1480 3" SHANK 12d COMMON 0.1480 3 1/4" SHANK 16d COMMON 0.1620 3 1/2" SHANK 10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148" 0 x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE SHANK AND THREADED PORTIONS PER NDS 12.1.4.2. CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS, SCREWS, OR BOLTS IN EACH MEMBER. INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. RATED SHEATHING RATED SHEATHING SHALL BE GRADE C-D INT-APA WITH EXTERIOR GLUE OR OSB SHEATHING WITH EXTERIOR GLUE IN CONFORMANCE WITH IBC STANDARD 2303.1.5. EXISTING BUILDING CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. LEGEND DEFINITION DIRECTION OF FRAMING EXTENT OF FRAMING COLUMNS COLUMN BEARING ON BEAM BEAM CONTINUOUS OVER SUPPORT CONCRETE WALL SYMBOL DEFINITION NATIVE SOIL GRANULAR FILL STRUCTURAL STEEL RATED SHEATHING SHEAR WALL (SEE SCHEDULE) SYMBOL 1_1 1_1 P SWX O COLUMN MARK (SEE SCHEDULE) FOOTING MARK (SEE SCHEDULE) HOLDOWN MARK (SEE SCHEDULE) BEARING STUD WALL NON -BEARING STUD WALL BEARING STUDVV SHEAR WALL HANGER MARK (SEE SCHEDULE) FLAG NOTE (SEE PLAN NOTES) STEEL MOMENT FRAME CONN. O NON -BEARING STUD SHEAR WALL CMU WALL �V ABBREVIATIONS (A) AB ABOVE ANCHOR BOLT HORIZ HORIZONTAL KING POST KIP ALT ARCH ALTERNATE ARCHITECT BELOW KSI KIPS PER SQUARE INCH MECHANICAL MECH (B) MF MOMENT FRAME BLKG BM BLOCKING BEAM BOTTOM BETWEEN COMPLETE JOINT PENETRATION CLEAR NS NEAR SIDE ON CENTER OPPOSITE PLATE PLACES POUNDS PER SQUARE INCH OC BOT BTWN OPP PL CJP CLR PLCS PSI CIVIL) CONCRETE MASONRY UNIT COLUMN CONCRETE CONNECTION PSF POUNDS PER SQUARE FOOT COL P/T POSTTENSIONED CONIC PT PRESSURE TREATED REINFORCING CONN REINF CONT CONTINUOUS REQ'D REQUIRED DBL DOUBLE DETAIL SCHED SIM SCHEDULE SIMILAR DIET DIM EA DIMENSION SOG SLAB ON GRADE STANDARD SHEAR WALL TOP OF CONCRETE EACH STD ELEV ELEVATION SW EXIST EXISTING TOC EXP EXPANSION FLOOR TOS TOP OF STEEL TOP OF WALL TYPICAL UNLESS NOTED OTHERWISE FLR TOW FDN FTG FOUNDATION FOOTING TYP LINO FS FH FAR SIDE VFY VERIFY FULL HEIGHT GLUE -LAMINATED BEAM VIF VERIFY IN FIELD VERTICAL GLB VERT Welding performed on -site shall be performed by a WABO certified welder and be inspected by a qualified third party inspector. Provide documents to inspector for any off site welding. UNIT Al AT EXISTING ROTTED STUDS, ADD NEW 2x4 HF STUD — 0.131"0 x 3" NAILS @ 6" OC — REPLACE EXISTING DBL PT SILL PLATE — CONCRETE TOPPING SLAB — A35 W/ (12) PH6121 SCREWS @ 16" OC, TYP EA SIDE OF FILLER BLOCK REMOVE AND REPLACE EXISTING HANGERS W/ LIKE -KIND EXIST JOIST PER PLAN J (2) ROWS OF 5/8" 0 THRU BOLTS @ 12" OC, STAGGERED CHANNEL PER PLAN BEAM PER PLAN SECTION SCALE: 1" = V-0" ❑0 v PARTIAL MAIN FLOOR FRAMING PLAN SCALE: 1/4" = V-0" UNIT A2 NOTE: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY SHORING 2. CONTACT FOR IF ADDITIONAL ROT IS DISCOVERED 3. PAINT ALL EXISTING SURFACES WHERE ROT IS REMOVED W/ KILZ OR EQUIVALENT APPROXIMATE EXTENT OF ROT (± 10 1/2" DEEP); REMOVE AND REPLACE W/ FILLER BLOCK N \ N 2 1/2" MIN. � CONTACT FOR IF ROT --- EXTENDS DEEPER N \ [V EXIST TOPPING SLAB & SHEATHING EXIST JOISTS PER PLAN + LN - THRU BOLTS PER DET 2 �3/16 )/ N + PL 1/4 x 3 x 0'-8" W/ (2) 1/2"0 x 6" LAG SCREWS, MIN POST PER PLAN; ATTACH TO EXISTING POST W/ 5/8" 0 x 7" LAG SCREWS @ SECTION 12" OC, STAGGERED (8 MINIMUM) PARAPET ELEV = 20'-0" _ROOF LEVEL ELEV = 19'-0" _$SECOND FLOOR �ELEV = 9'-2" _$FIRST FLOOR �ELEV = 0'-0" BASEMENT LEVEL ELEV = 4-2" 2'-0" 0 2'-0" PARTIAL BUILDING ELEVATION (SOUTHWEST CORNER 4'-0" C G ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 �1�THI' � OF WAS$ iJsL��ti 'ZONAL 09/06/24 i DESIGN: BTJ DRAWN: JOS CHECK: MTM JOB NO: 24296.10 DATE: 09/06/24 (All Q RECEIVED Sep 19 2024 CITY OF EDMONDS DEVELOPMENT SERVICES -V DEPARTMENT Z r Q Q a— Z D Q V ! W La I-- Z o 0 Z 0C Uj Cy) �--� � Q Q Ld cy— Q�� 0 0 Q H U Q Z O v LL ., Z z Lo W (� SHEET: S1.1 SCALE: 1" = V-0" SCALE: 1/4" = V-0"