APPROVED BLD2024-0917+ SITE & ARCH PLANS+7.15.2024_10.50.44_AM+4377274 (2)PARKVIEW TWIN CONDOMINIUMS 517B & 517D 4 TH A VENUE S EDMONDS, WA 98020 APPLICANT PARKVIEW TWIN CONDOMINIUMS HOA 517 & 519 4TH AVENUE S EDMONDS, WA 98020 CONTRACTOR ADVANTAGE CONTRACTORS, INC MICHAEL COOK 24202 118TH AVENUE NE ARLINGTON, WA 98223 STRUCTURAL ENGINEER SIDESWAY ENGINEERING, PLLC CHRIS BERNARDS, PE, SE 20305 87TH AVENUE W. EDMONDS, WA 98026 APPROVED PARCEL NUMBERS 00649300100200(517B) 00649300100400(517D) LEGAL DESCRIPTION BEGINNING AT A POINT 160 FEET WEST AND 132 FEET SOUTH OF THE NORTHEAST CORNER OF THE SOUTH HALF OF THE NORTHEAST QUARTER OF THE NORTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 26, TOWNSHIP 27 NORTH, RANGE 3 EAST, W.M.; THENCE RUNNING WEST 130 FEET TO THE EAST LINE OF THAT CERTAIN PROPERTY DEEDED TO THE CITY OF EDMONDS, BY DEED RECORDED UNDER SNOHOMISH COUNTY AUDITOR'S FILE NO. 956380; THENCE SOUTH ALONG SAID EAST LINE 132 FEET; THENCE EAST 130 FEET TO A POINT SOUTH OF POINT OF BEGINNING; THENCE NORTH 132 FEET TO THE POINT OF BEGINNING. SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. SCOPE OF WORK REPAIR DRY ROT DECKS FOR UNITS 517B AND 517D WHICH CANTILEVER OFF THE WEST SIDE OF THE EXISTING CONDOMINIUM BUILDING. REMOVE FAILED TOPPING SLAB AND EXISTING PRE -MANUFACTURED HANDRAIL SYSTEM TO FACILITATE THE DRY ROT REPAIR OF THE EXISTING SHEATHING, JOISTS, BEAMS, AND RIM BOARDS. UPGRADE FRAMING AS REQUIRED TO CONFORM TO THE 2021 IBC. INSTALL NEW DECK SURFACE, WEATHERPROOFING (BY OTHERS), AND REINSTALL THE EXISTING HANDRAIL WITH ADDITIONAL STRENGTHENING OF BLOCKING AND TENSION STRAPS. PLANS MUST BE ON JOB SITE City Of Edmonds Building Department Work DRY ROT REPAIR- DECKS -------------------------------------------- Address 517 4TH AVE S ------------------------------------------ -------------------------------- Owner LORAH & NELSON -------------------- -------------------- Approved Date 07/24/2024 Building Official Permit NumberBLD2024-0917- UNIT B BLD2024-0918- UNIT D ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE HARDWARE & FASTENERS IN CONTACT WITH PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. IN THE ABSENCE OF MANUFACTURER'S RECOMMENDATIONS A MINIMUM OF ASTM A 653 TYPE G185 ZINC -COATED GALVANIZED STEEL, OR EQUIVALENT, SHALL BE USED. IRC R317.3.1 IBC 2304.10.5.1 GUARDS SHALL NOT HAVE AN OPENING FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT THAT WILL ALLOW THE PASSAGE OF A 4" SPHERE IN ACCORDANCE WITH 2O21 IBC 1015.4. SITE PLAN SCALE: 1 " = 10'-0" EXIST TREE, TYP PROPERTY LINE 130.0' F'HUF'tH I Y LINL 10 10 G z cc LU Cl- 20 Z W W Z W ' I..I__I ' A C v J Lu :73 N o Q = Q � 0 � Z Lo O 4 W �1 1� Q RECEIVE Jul 16 2024 U LLI 7 O CITY OF EDMONDS DEVELOPMENT SERVICE DEPARTMENT O A. � aL ONAL 07/12/24 REV. DATE DESCRIPTION 0 07112124 PERMIT SUBMITTAL PROJECT NO.: 23088.02 DESIGNED BY: CAB DRAWN BY: CAB CHECKED BY: CAB SHEET TITLE: SITE PLAN A SHEET NO.: A1.1 STRUCTURAL NOTES CODE ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS AND THE INTERNATIONAL BUILDING CODE (IBC) AS AMENDED BY THE LOCAL JURISDICTION. SPECIFICATIONS AND STANDARDS WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. DESIGN LOADS LIVE LOADS: RESIDENTIAL: 40 PSF DECK: 60 PSF SPECIAL INSPECTION SPECIAL INSPECTION IS NOT REQUIRED UNLESS OTHERWISE NOTED BY THE JURISDICTION. STRUCTURAL OBSERVATION STRUCTURAL OBSERVATION IS NOT REQUIRED. WOOD FRAMING ALL WOOD FRAMING SHALL BE PERFORMED IN ACCORDANCE WITH IBC CHAPTER 23, ANSI/AWC "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION", AND AITC "TIMBER CONSTRUCTION MANUAL". SAWN LUMBER SHALL BE IDENTIFIED BY THE GRADE MARK OF AN AGENCYAPPROVED BYAN ACCREDITATION BODY COMPLIANT WITH DOC PS 20. ALL GRADES SPECIFIED IN THE STRUCTURAL DRAWINGS ARE MINIMUM STANDARDS AND SHALL BE AS FOLLOWS: • STUDS, PLATES, AND BLOCKING DOUG-FIR STUD GRADE • JOISTS DOUG-FIR #2 • 4x OR SMALLER BEAMS AND HEADERS DOUG-FIR #2 • 6x OR LARGER BEAMS AND HEADERS DOUG-FIR #1 • POSTS AND TIMBERS DOUG-FIR #2 WOOD FRAMING SHALL BE KILN -DRIED TO A MAXIMUM MOISTURE CONTENT OF 19%. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY, OR EXPOSED TO EARTH OR WEATHER SHALL BE PRESSURE TREATED IN ACCORDANCE WITH AWPA STANDARD U1 AND M4 FOR THE SPECIES, PRODUCT, PRESERVATIVE, AND END USE REQUIRED. GLUED LAMINATED TIMBER SHALL BE MANUFACTURED AND IDENTIFIED IN CONFORMANCE WITH ANSI/AITC A 190.1 AND ASTM D3737. UNLESS OTHERWISE SPECIFIED, ALL GLUED LAMINATED TIMBERS SHALL BE DOUGLAS FIR SPECIES. SINGLE SPAN BEAMS SHALL BE COMBINATION 24F-V4 AND MULTI -SPAN BEAMS OR BEAMS THAT CANTILEVER SHALL BE COMBINATION 24F-V8. ALL EXPOSED GLULAMS SHALL HAVE AN ADDITIONAL TENSION LAMINATION SUBSTITUTED FOR A CORE LAMINATION ON THE TENSION SIDE OF UNBALANCED 24F-V4 BEAMS AND ON BOTH SIDES OF BALANCED 24F-V8 BEAMS. STRUCTURAL WOOD PANEL SHEATHING USED ON WALLS, FLOORS, OR ROOFS SHALL CONFORM TO THEIR SPECIFIC REQUIREMENTS IN DOC PS 1, DOC PS 2, OR ANSI/APA PRP 210. PLYWOOD SHALL BE GRADE C-D WITH EXTERIOR GLUE. REFER TO IBC SECTIONS 2303.1.4, 2304.6, AND 2304.7 FOR ADDITIONAL COMPLIANCE REQUIREMENTS. PRE -MANUFACTURED JOISTS, BEAMS, AND TRUSSES PRE -MANUFACTURED JOISTS, BEAMS, AND TRUSSES SHALL BE SIZED, SPACED, AND DETAILED TO MATCH THE LOADING AND DIMENSIONAL REQUIREMENTS INDICATED ON THE STRUCTURAL DRAWINGS. TRUSSES SHALL COMPLY WITH IBC 2303.41 I -JOISTS SHALL COMPLY WITH IBC 2303.1.2, AND COMPOSITE BEAMS SHALL COMPLY WITH 2303.1.9. THE MANUFACTURER'S DESIGNER IS RESPONSIBLE FOR CODE COMPLIANCE AND SHALL PROVIDE SHOP DRAWING AND CALCULATION SUBMITTALS AS SPECIFIED. ENGINEER AND BUILDING OFFICIAL APPROVAL IS REQUIRED PRIOR TO FABRICATION OF PRE -MANUFACTURED COMPONENTS. REFER TO THE DESIGN LOADS FOR BASIC STRUCTURAL LOADING REQUIREMENTS. REFER TO THE ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR ADDITIONAL LOADING AND OPENING REQUIREMENTS NOT SPECIFICALLY NOTED ON THE STRUCTURAL DRAWINGS. DEFLECTIONS SHALL NOT EXCEED L/480 FOR LIVE LOADS OR L/360 FOR TOTAL LOADS UNLESS APPROVED IN WRITING BY THE ENGINEER. ALL TRUSSES WITH A DEPTH EQUAL TO OR GREATER THAN 24" SHALL BE DESIGNED FOR A BOTTOM CHORD LIVE LOAD OF 10PSF, NOT APPLIED CONCURRENT WITH THE TOP CHORD LIVE LOAD. PROVIDE TEMPORARY BRACING UNTIL SHEATHING AND PERMANENT BRACING IS INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. THE MANUFACTURER SHALL PROVIDE ALL SPECIALTY ITEMS REQUIRED FOR A COMPLETE INSTALLATION OF THE SYSTEM (INCLUDING BUT NOT LIMITED TO FULL DEPTH BRIDGING, BLOCKING, WEB STIFFENERS, AND PRODUCT SPECIFIC CONNECTORS. NAILS, SCREWS, BOLTS, AND CONNECTORS REFER TO THE PLANS, NOTES, SCHEDULES, AND DETAILS FOR ALL NAILING REQUIREMENTS. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.9.1. ALL NAILS SHALL CONFORM TO THE STANDARD DIMENSIONS OF COMMON NAILS AS DEFINED BY THE NDS AND SHALL MEET THE FOLLOWING MINIMUM GUIDELINES: 8d = 0.131 "Q x 2 1/2" 10d = 0.14870 X 3" 16d=0.162"0x31/2" 10d BOX NAILS (0.128"0 x 3) MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148.0 x 3 1/4'), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THE DRAWINGS. OTHER NAILS MAY BE SUBSTITUTED ONLY WITH THE ENGINEER'S APPROVAL PRIOR TO START OF CONSTRUCTION. ALL LAG SCREWS AND BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE STANDARD CUT WASHERS UNDER THE HEADS AND NUTS OF ALL LAG SCREWS AND BOLTS BEARING ON WOOD. LEAD HOLES FOR BOLTS SHALL BE PROVIDED AND SHALL BE A MINIMUM OF 1/32" AND A MAXIMUM OF 1/16" LARGER THAN THE BOLT DIAMETER. LEAD HOLES FOR LAG SCREW SHANK AND THREADS SHALL BE PER NDS 11.1.4.2. ALL WOOD CONNECTORS SHALL BE SIMPSON STRONG -TIE OR ENGINEER APPROVED EQUIVALENT. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS USING THEIR SPECIFIED NUMBER AND SIZE OF FASTENERS. IF STRAPS CONNECT TWO MEMBERS, PLACE 1/2 OF THE NAILS, SCREWS, OR BOLTS INTO EACH MEMBER. ALL NAILS, SCREWS, BOLTS, AND METAL CONNECTORS IN CONTACT WITH PRESSURE TREATED OR FIRE RETARDANT TREATED WOOD SHALL BE HOT DIP GALVANIZED IN ACCORDANCE WITH ASTM A153. WOOD FRAMING GENERAL NOTES SILL PLATES BEARING ON CONCRETE FOUNDATIONS SHALL BE PRESSURE TREATED AND SHALL ATTACH TO THE CONCRETE WITH 1/2"0 ANCHOR BOLTS EMBEDDED 7" MINIMUM. PLACE ANCHORS AT 4'-0" OC MAXIMUM FOR SHEAR WALLS AND AT 6'-0" OC FOR BEARING AND PARTITION WALLS. USE A MINIMUM OF (2) ANCHOR BOLTS PER SILL PLATE AND PLACE ONE WITHIN 12" OF EACH END OF EACH PIECE. REFER TO THE SHEAR WALL SCHEDULE FOR MORE STRINGENT ANCHORAGE SIZE AND SPACING REQUIREMENTS. CONTRACTOR SHALL INSTALL 3 GAUGE PLATE WASHERS BENEATH EACH NUT AT EACH ANCHOR BOLT IN A SHEAR WALL THAT EXTEND TO WITHIN 1/2" OF SHEATHED EDGE. ALL SHEAR AND/OR BEARING WALLS SHALL BE FRAMED WITH 2x STUDS 0 16" OC. REFER TO PLAN NOTES FOR TYPICAL HEADER SIZES NOT SPECIFICALLY CALLED OUT. ALL HEADERS SHALL BE SUPPORTED BYA MINIMUM OF (1) CRIPPLE AND (1) FULL HEIGHT STUD. COLUMNS BELOW FLUSH FRAMED MULTIPLE JOIST BEAMS SHALL BE EQUAL IN WIDTH TO THE BEAM. ALL COLUMNS NOT CALLED OUT SHALL BE (2) STUDS. BEAMS SHALL HAVE FULL BEARING ON COLUMNS AND POSITIVE CONNECTION SHALL BE PROVIDED. PROVIDE SOLID BLOCKING BETWEEN JOISTS AND RAFTERS AT ALL SUPPORTS, AT 8'-0" OC MAXIMUM SPACING BETWEEN SUPPORTS, AND BENEATH PARTITIONS PERPENDICULAR TO THE DIRECTION OF FRAMING. INSTALL DOUBLE JOISTS UNDER PARTITIONS EXTENDING ONE HALF OR MORE OF THE JOIST SPAN. MINIMUM NAILING REQUIREMENTS SHALL BE PER IBC TABLE 2304.10.1. THE USE OF NAIL GUNS IS APPROVED IF NAILING INTO THE DIAPHRAGMS IS FLUSH WITH FACE OF SHEATHING. NAIL PENETRATIONS GREATER THAN 1/16" ARE NOT ACCEPTABLE. NOTCHES AND HOLES IN WALL STUDS ARE ALLOWED WITHIN THE PARAMETERS OF IBC SECTIONS 2308.5.9 AND 2308.5.10. NOTCHES AND HOLES IN JOISTS AND RAFTERS ARE ALLOWED WITHIN THE PARAMETERS OF IBC SECTIONS 2308.4.2 AND 2308.7.4. VERTICAL SHRINKAGE WILL OCCUR AND ACCUMULATE AT EACH LEVEL FROM THE WOOD DRYING OVER TIME. THIS IS ESTIMATED TO BE APPROXIMATELY 0.15" PER FLOOR AND ASSUMES THE WOOD HAS AN INITIAL MOISTURE CONTENT OF 19% OR LESS. ADDITIONAL SHRINKAGE WILL OCCUR IF THE MOISTURE CONTENT IS HIGHER. THE CONTRACTOR SHALL ALLOW FOR THIS MOVEMENT IN THEIR INSTALLATION OF ALL VERTICAL ASSEMBLIES INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, MECHANICAL, AND ARCHITECTURAL SYSTEMS. GENERAL NOTES STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE ARCHITECTURAL, CIVIL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. REFER TO THE ARCHITECTURAL DRAWINGS FOR ELEVATIONS, SLOPES, NON -BEARING WALLS, STAIRS, CURBS, DRAINS, RAILINGS, WATERPROOFING, FINISHES, ETC. REFER TO THE ARCHITECTURAL, CIVIL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF PIPES, VENTS, DUCTS, AND OTHER OPENINGS NOT SPECIFICALLY INDICATED ON THE STRUCTURAL DRAWINGS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND FIELD CONDITIONS FOR COMPATIBILITY WITH THE PLANS, SPECIFICATIONS, AND REFERENCED STANDARDS BEFORE PROCEEDING WITH ANY WORK. THE MOST STRINGENT REQUIREMENT SHALL GOVERN ANY CONFLICT UNLESS APPROVED IN WRITING OTHERWISE. ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN TEAM BEFORE PROCEEDING. CONTRACTOR SHALL BE RESPONSIBLE FOR STRENGTH AND STABILITY OF ANY PARTLY COMPLETED STRUCTURE. CONTRACTOR IS SOLELY RESPONSIBLE FOR JOB SITE SAFETY AND SHALL PROVIDE TEMPORARY SHORING AND SUPPORT AS REQUIRED UNTIL THE STRUCTURE HAS BEEN COMPLETED. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE DESIGN TEAM FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES ON SHOP DRAWINGS DO NOT SATISFY THIS REQUIREMENT. REVIEW OF ALTERNATE SYSTEMS MAY BE AN ADDITIONAL SERVICE BY THE ENGINEER. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE DESIGN TEAM. LEGEND DEFINITION SYMBOL DEFINITION SYMBOL DIRECTION OF FRAMING NATIVE SOIL lift GRANULAR FILL I I m I m I m I m — — — — — EXTENT OF FRAMING COLUMNS COLUMN BEARING ON BEAM BEAM CONTINUOUS OVER SUPPORT CONCRETE WALL P ell STRUCTURAL STEEL RATED SHEATHING SHEAR WALL (SEE SCHEDULE) COLUMN MARK (SEE SCHEDULE) SWX O X O BEARING STUD WALL NON -BEARING STUD WALL BEARING STUD SHEAR WALL NON -BEARING STUD SHEAR WALL CMU WALL FOOTING MARK (SEE SCHEDULE) HOLDOWN MARK (SEE SCHEDULE) , HANGER MARK (SEE SCHEDULE) FLAG NOTE (SEE PLAN NOTES) STEEL MOMENT FRAME CONN. XXXXX ABBREVIATIONS (A) ABOVE AB ANCHOR BOLT ALT ALTERNATE GLB GLUE -LAMINATED BEAM HORIZONTAL HORIZ KP KING POST ARCH ARCHITECT KSI KIPS PER SQUARE INCH (B) BELOW L ANGLE BD BAR DIAMETER MECH MECHANICAL BLKG BLOCKING MF MOMENT FRAME BM BEAM MTL METAL BOT BOTTOM NS NEAR SIDE BRNG BEARING OC ON CENTER OPPOSITE PLATE PLACES POUNDS PER SQUARE INCH POUNDS PER SQUARE FOOT POST TENSIONED BTWN BETWEEN OPP CJP COMPLETE JOINT PENETRATION PL CLR CLEAR PLCS CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONN CONNECTION PSI PSF P/T PT PRESSURE TREATED CONT CONTINUOUS REINF REINFORCING COORD COORDINATE REQ'D REQUIRED DBL DOUBLE SCHED SCHEDULE DET DETAIL SIM SIMILAR DIA DIAMETER SOG SLAB ON GRADE DIM DIMENSION STD STANDARD DIR DIRECTION STIFF STIFFENER EA EACH STL STEEL ELEV ELEVATION SYMM SYMMETRICAL ES EACH SIDE SW SHEARWALL TOP OF CONCRETE TOP OF STEEL EX EXISTING TOC EXP EXPANSION TOS FLR FLOOR TOW TOP OF WALL FDN FOUNDATION TYP TYPICAL FTG FOOTING FS FAR SIDE GC GENERAL CONTRACTOR LINO UNLESS NOTED OTHERWISE VERT VERTICAL WF WIDE FLANGE Z W W Z o W �i c a� A v J Lu N Q '::7) U` 0 O � Q Q � O Lo m Lo cc Q RECEIVE Jul 16 2024 wCITY 7 O OF EDMONDS DEVELOPMENT SERVICE DEPARTMENT CL O A. pF �PASk � 40785 ssIONAL 07/ 12/ 2� REV. DATE DESCRIPTION 0 07112124 PERMIT SUBMITTAL PROJECT NO.: 23088.02 DESIGNED BY: CAB DRAWN BY: CAB CHECKED BY: CAB SHEET TITLE. STRUCTURAL NOTES SHEET NO.: S1.1 r TYPICAL FLOOR FRAMING PLAN SCALE: 114"= 1'-0" 7STING DECK D WORK HERE) 7STING AWNING D WORK HERE) 7STING DECK TO REPAIRED, TYP I I I I I I I I I I I I I I I I I I I I I I I I �---------------� I GENERAL DECK REPAIR NOTES: 1. REMOVE FAILED TOPPING SLAB & FLOOR COVERINGS FROM ALL EXISTING DECKS. 2. REMOVE EXISTING HANDRAIL SYSTEMS AND STORE FOR FUTURE RE -INSTALLATION. 3. REMOVE EXISTING FASCIA AND STORE IF IT REMAINS IN GOOD CONDITION FOR FUTURE RE -INSTALLATION. 4. EVALUATE EXISTING SHEATHING FOR DRY ROT & REPLACE WITH SIMILAR THICKNESS APA RATED SHEATHING IN MINIMUM 32" x 32" SECTIONS. 5. EVALUATE EXISTING RIM & JOIST FRAMING FOR DRY ROT. REPLACE WITH LIKE KIND IF DRY ROT OBSERVED IN 112" OR MORE OF THE JOIST DEPTH OR IF EITHER JOIST END HAS CRUSHED GREATER THAN 118". IF RIM IS NOT CONTINUOUS, REPLACE WITH LIKE KIND. IFJOIST HAS BEEN REPAIRED WITH SMALLER SIZED JOIST, REPLACE WITH NEW FULL DEPTH JOIST. 6. SISTER 1 3/4"LVL TO EACH EXISTING BEAM ON THE INTERIOR FACE. RIP LVL TO MATCH THE BEAM DEPTH WHICH VARIES FROM 4x10 TO 4x12. REFER TO DETAILS FOR FASTENER REQUIREMENTS. 7. INSTALL NEW SLOPING PRESSURE TREATED PLYWOOD DECK SURFACE TO MATCH THE DEPTH OF THE EXISTING TOPPING SLAB THAT WAS REMOVED. 9. RE -INSTALL OR ADD NEW FASCIA AND TRIM AROUND THE DECK PERIMETER AND BEAMS BELOW. 10. INSTALL NEW CONTINUOUS DECK MEMBRANE SURFACE THAT LAPS UP 6" MINIMUM UNDER THE EXISTING SIDING AND OVER NEW DRIP EDGE FLASHING INSTALLED AROUND THE DECK PERIMETER. ALL WATERPROOFING DETAILS AND SYSTEMS ARE TO BE DESIGNED AND INSTALLED BY OTHERS. 11. RE -INSTALL THE EXISTING HANDRAIL SYSTEMS TO THE DECK. INCORPORATE NEW BLOCKING AND STRAPPING AT EACH HANDRAIL POST PER THE APPLICABLE DETAILS ON S3.1. HANDRAIL PENETRATIONS AT PERIMETER SHALL BE SEALED AND FLASHED BY OTHERS. 12. INSTALL NEW VENTED ALUMINUM OR PVC CEILING PANELS AS APPROVED BY HOA. 2 EXISTING 2x RIM & /Ir 1 4x BEAM BELOW S4.1 1 314" L VL BEAM DEI TYP. ATTI PER DETI 2 S4.1 0 0 0 o w w w J O O N N N c V) N N N W W W W W W W W W U U U Q Q Q Q Q Q 2 S4.1 \,—EXISTING 4x BEAM EXTENDS INTO UNIT LINE OF BUILDING TYPICAL DECK FRAMING PLAN SCALE: 112" = 1 '-0" UNIT SPECIFIC WORK: RIPPED TO MATCH 'TH (4x 10 OR 4x 12), I CH TO 4x BEAM IILS ON S4.1 �®' E mil III REFER TO GENERAL DECK REPAIR NOTES FOR ALL UNITS. NOTIFY FOR IFANYADDITIONAL STRUCTURAL DEFECTS ARE OBSERVED WHICH COULD AFFECT THE REPAIR WORK TO BE PERFORMED ON THE DECKS OR THE STRUCTURAL SYSTEM OF THE CONDOMINIUM BUILDINGS. UNIT 517B: REPLACE RIM BOARD, UPGRADE BEAMS, REPLACE DRY ROT SHEATHING. UNIT 517D: REPLACE RIM BOARD, (2) JOISTS, UPGRADE BEAMS, REPLACE DRY ROT SHEATHING. Z 4- W W Z W o %o 010 �i c '• W a� A v J Lu � N Q O V O � O O m W Q RECEIVE Jul 16 2024 wCITY 7 OF EDMONDS DEVELOPMENT SERVICE DEPARTMENT Q CL O� A' WA 4078' O ` ORAL 5'1 �yti SSIONAL 07/12/24 REV. DATE DESCRIPTION 0 07112124 PERMIT SUBMITTAL PROJECT NO.: 23088.02 DESIGNED BY: CAB DRAWN BY: CAB CHECKED BY: CAB SHEET TITLE: FLOOR FRAMING PLAN I •J SHEET NO.: S2.1 EXISTING & PROPOSED NORTH ELEVATION SCALE. 3/16" = 1 '-0" POST a RIM PARALLEL TO JOIST EXISTING PRE-MFR GUARD. RE -INSTALL W/ NEW THRU BOLT EXTENDING TO TENSION DEVICE SEAL & FLASH HANDRAIL PENETRATION (BY OTHERS) FRAMING PER PLAN 10d Cd 4" OC cc 1800 LB TENSION STRAP EA SIDE OF BLKG 2x DF BLKG @a EA POST. ADD (3) 10d RING SHANK NAILS EA END GUARD SECTIONS SCALE: 1 " = 1'-0" POST @a RIM PERPENDICULAR TO JOIST EXISTING PRE-MFR GUARD. RE -INSTALL W/ NEW THRU BOLT EXTENDING TO TENSION DEVICE. SEAL & FLASH HANDRAIL PENETRATION (BY OTHERS) 1:111►I921:1001TA FRAMING PER PLAN 1800 LB TENSION STRAP Ca JOIST. IF POST LOCATED BTWN JOISTS, PROVIDE (1) STRAP C EA ADJACENT JOIST REMOVE AND RE -INSTALL HANDRAILS UPON COMPLETION OF DECK REPAIR, TYP EXISTING & PROPOSED WEST ELEVATION SCALE: 3/16" = 1 '-0" Z OC `� W W c\I Z W o i i '• I.. j O � N � O Q = Q � Z Lo O m Uj W_ Q RECEIVE Jul 16 2024 wCITY 7 OF EDMONDS DEVELOPMENT SERVICE DEPARTMENT Q CL A. pF WAg� � nL Cs~ �SIoNAL 07112/ 24 REV. DATE DESCRIPTION 0 07112124 PERMIT SUBMITTAL PROJECT NO.: 23088.02 DESIGNED BY: CAB DRAWN BY: CAB CHECKED BY: CAB SHEET TITLE: ELEVATIONS & DETAIL A SHEET NO.: S3.1 NOTES 1. DECK SURFACE, FLASHING, & WATERPROOFING BY OTHERS. INSTALL IN STRICT ACCORDANCE W/ MFR'S REQUIREMENTS. 2. NOTIFY FOR IF PT DECK SLOPE SYSTEM IS NOT COMPATIBLE W/ EXISTING SLAB DEPTH WHICH WILL BE REMOVED. 3. REFER TO DETAIL 2 FOR ADDITIONAL INFORMATION NOT SPECIFICALLY NOTED HERE. 4. REFER TO SHEET S3.1 FOR INFORMATION ON THE EXISTING HANDRAIL SYSTEM TO BE REMOVED AND RE -INSTALLED ONCE DRY ROT REPAIRS HAVE BEEN COMPLETED. EXISTING RIM REPLACED WHERE REQUIRED LVL BEAM PER PLAN SISTERED TO EXISTING 4x BEAM W/ (2) 5" LEDGERLOK @a 8" OC. REFER TO DETAIL 2 FOR ADDITIONAL FASTENER REQUIREMENTS. EXISTING BEAM PER PLAN DECK SECTION SCALE: 1 " = 1 '-0" EXTEND & ADHERE DECK MEMBRANE 6" UP EXTERIOR WALL. FLASHING & MEMBRANE SYSTEM BY OTHERS. PROVIDE PT 314" SHEATHING OVER PT 2x4 SLEEPER Ca 16" OC RIPPED FROM 1 112" TO 0". VFY DEPTH W/ EXISTING TOPPING SLAB TO BE REMOVED. EXISTING JOISTS & SHEATHING PER PLAN EXISTING LEDGER. VFY/PROVIDE 10d Ca 6" OC THRU SHEATHING. VFY/PROVIDE 112"0 LAG OR 4" LEDGERLOK ca 12" OC 112" LEDGER SECTION SCALE: 1"= 1'-0" EXISTING FLOOR JOISTS NOTES 1. DECK SURFACE, FLASHING, & WATERPROOFING BY OTHERS. INSTALL IN STRICT ACCORDANCE W/ MFR'S REQUIREMENTS. 2. NOTIFY FOR IF PT DECK SLOPE SYSTEM IS NOT COMPATIBLE W/ EXISTING SLAB DEPTH WHICH WILL BE REMOVED. PROVIDE PT 3/4" SHEATHING OVER PT 2x4 SLEEPER 9 16" OC RIPPED FROM 1 112" TO 0". VFY DEPTH W/ EXISTING TOPPING SLAB TO BE REMOVED. EXISTING JOISTS & SHEATHING. REPLACE DRY ROT JOISTS PER PLAN Z' FLASHING BY OTHERS. LAP DECK SURFACE OVER FLASHING AS REQD BY MFR CEDAR TRIM & CAULK WRAP AROUND BEAM (DESIGN BY OTHERS) NOTES 1. DECK SURFACE, FLASHING, & WATERPROOFING BY OTHERS. INSTALL IN STRICT ACCORDANCE W/ MFR'S REQUIREMENTS. 2. NOTIFY FOR IF PT DECK SLOPE SYSTEM IS NOT COMPATIBLE W/ EXISTING SLAB DEPTH WHICH WILL BE REMOVED. 3. REFER TO DETAIL 1 FOR ADDITIONAL INFORMATION NOT SPECIFICALLY NOTED HERE. 4. REFER TO SHEET S3.1 FOR INFORMATION ON THE EXISTING HANDRAIL SYSTEM TO BE REMOVED AND RE -INSTALLED ONCE DRY ROT REPAIRS HAVE BEEN COMPLETED. PROVIDE PT 314" SHEATHING OVER PT EXTEND & ADHERE DECK MEMBRANE 2x4 SLEEPER 0 16" OC RIPPED FROM 6" UP EXTERIOR WALL. FLASHING & 1 112" TO 0". VFY DEPTH W/ EXISTING MEMBRANE SYSTEM BY OTHERS. TOPPING SLAB TO BE REMOVED. EXISTING LEDGER. EXISTING JOISTS & REFER TO DETAIL 3. EXISTING FLOOR SHEATHING. REPLACE DRY JOISTS I ROT JOISTS PER PLAN —\ • • • • • • • • BEAM PER PLAN SISTERED EXIST BEAM PER TO EXISTING 4x BEAM W/318 (2) 5" LEDGERLOK ca 8" OC 2 DISTST, TY O END PLAN .- ADD (8) 5" LEDGERLOK Ca 2'-6" FROM 2'-8" MIN EXIST EXIST EXTERIOR WALL & (5) 9 WALL. PROVIDE 2 718" STUD WALL PER VERT SPACING & 1 " BETWEEN ROWS BEAM IN GOOD CONDITION PLAN DECK SECTION SCALE: 1 " = 1'-0" 1- 4 cc W W 1.4 Z o W m c A v J Z � Uj � N WO 6) O � Q � CO Lo C Uj W L Q RECEIVE ,. Jul 16 2024 wCITY OF EDMONDS DEVELOPMENT SERVICE DEPARTMENT O CL O A' 1PA ' z CUD) Oss' ORAL 5'�� ONAL 01/ 12/ 24 REV. DATE DESCRIPTION 0 07112124 PERMIT SUBMITTAL PROJECT NO.: 23088.02 DESIGNED BY: CAB DRAWN BY.- CAB CHECKED BY: CAB SHEET TITLE: FRAMING DETAILS k SHEET NO.: S4.1