Loading...
APPROVED PLN BLD RESUB1 BLD2024-0989+Architectural_Plan+9.5.2024_5.07.28_PM+4483600APPROVED BY PLANNING C)111�41a__a_ Oct 01 2024 Nothing in the permit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the permit application, regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate enforcement action. 1 WHERE ADDITIONS OR ALTERATIONS REQUIRE A PERMIT 1 TO BE ISSUED INTERCONNECTED SMOKE ALARM AND CO DETECTORS THROUGHOUT THE DWELLING IS REQUIRED. 1 � REFER TO 2021 IRC R314 AND R315 FOR MORE 1 INFORMATION. 1 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE City Of Edmonds Building Department ------------------------------------- Work ADU Address 403 12TH PL N ---------------------------- ----------------------------- Owner MEAD --------------------------------------------- --- ------------------------------------- Approved Date CL9/06/20 Building Official --------------------------------- Permit Number BLD2024-0989----------------------------------------- 60x48 Slider sill 37 Z 12x12 bedroom 144sgft ADU ' 0 1 SD Ceiling 8' \� ( 0 L SD Shower �Tl� 32x40 <> 50 CFM w Exh o Bathroom ADU 36x80 O ADU SD&CO Ceiling 7' m 3 O O w SD z iY a 30x80 sink CO 0 Electric SD service a light , Panel z0 u kitchen ti o x ADU o io cx,,i a� Q a a� laundry 3 x <> w Common 150 CFM z � Exh °J Ceiling 71" light � — 30x80 aa�a� ao Ln 8x13 bedroom/office 0 v m n 104sclft SD a a . m °1 rao o io ADU Ceiling 8' 48x48 Slider bedroom 36x80 family room 0 fireplace SD UQ O CO CO mechanical 0 ligIt 0 SD bedroom/office LEVEL 1 Scale 1/8" = V Project: ADU within existing building structure at 403 12th PI N, Edmonds, WA 98020 Contact: Tanya Mead, manager.svp@gmail.com ADU will have a separate address Notes: 1. ADU area marked "ADU" in red. 2. Floor area of ADU is 477 sq.ft. 3. Floor area of main unit is 2,993 sq. ft. 4. All ADU & main smoke detectors hardwired & interconnected. 5. All ADU & main CO detectors are hardwired. 6. All ADU (and main) bedroom windows are above grade, minimum openable area 6.1 sq.ft., min openable width 20", openable height 44". 7. Each ADU room has individually -controlled electric heater. 8. New partitions for separation are marked "NEW", everything else is existing. RESUB Jul 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 72x48 72x48 Slider Slider 30x80 (6' slider) Z bedroom bedroom Living Room 0 fl 0 SD j] SD fireplace O SD&CO light kitchen 2 of 32x80 `- LEVEL 2 O 32x80 SD 36x80 Scale 1/8" = 1' bedroom x `v c N Garage Project: ADU within existing building structure at 403 12th PI N, Edmonds, WA 98020 Contact: Tanya Mead, manager.svp@gmail.com ADU will have a separate address RESUB Jul 25 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT