APPROVED PLN BLD RESUB1 BLD2024-0989+Architectural_Plan+9.5.2024_5.07.28_PM+4483600APPROVED BY PLANNING
C)111�41a__a_
Oct 01 2024
Nothing in the permit approval process shall be
interpreted as allowing or permitting the maintenance
of any currently existing illegal, nonconforming or
unpermitted building, structure or site condition which
is outside the scope of the permit application, regardless
of whether such building, structure or condition is
shown on the site plan or drawing. Such building,
structure or condition may be the subject of a separate
enforcement action.
1
WHERE ADDITIONS OR ALTERATIONS REQUIRE A PERMIT 1
TO BE ISSUED INTERCONNECTED SMOKE ALARM AND CO
DETECTORS THROUGHOUT THE DWELLING IS REQUIRED.
1 �
REFER TO 2021 IRC R314 AND R315 FOR MORE 1
INFORMATION.
1
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
City Of Edmonds
Building Department
-------------------------------------
Work ADU
Address 403 12TH PL N
----------------------------
-----------------------------
Owner MEAD
--------------------------------------------- ---
-------------------------------------
Approved Date CL9/06/20
Building Official
---------------------------------
Permit Number BLD2024-0989-----------------------------------------
60x48 Slider
sill 37
Z
12x12 bedroom
144sgft
ADU '
0 1
SD
Ceiling 8' \� ( 0
L SD
Shower �Tl�
32x40
<>
50 CFM w
Exh o
Bathroom
ADU
36x80
O ADU
SD&CO
Ceiling 7'
m
3 O O
w SD
z iY
a
30x80
sink
CO
0
Electric
SD
service
a
light ,
Panel
z0 u kitchen
ti
o
x
ADU
o
io cx,,i
a�
Q a
a�
laundry 3 x
<>
w
Common 150 CFM
z
�
Exh
°J
Ceiling 71"
light
� —
30x80
aa�a�
ao Ln
8x13
bedroom/office
0
v m n
104sclft
SD
a a . m
°1 rao o
io
ADU
Ceiling 8'
48x48 Slider
bedroom
36x80
family room
0
fireplace SD UQ
O
CO
CO mechanical
0
ligIt
0
SD bedroom/office
LEVEL 1
Scale 1/8" = V
Project: ADU within existing building structure
at 403 12th PI N, Edmonds, WA 98020
Contact: Tanya Mead, manager.svp@gmail.com
ADU will have a separate address
Notes:
1. ADU area marked "ADU" in red.
2. Floor area of ADU is 477 sq.ft.
3. Floor area of main unit is 2,993 sq. ft.
4. All ADU & main smoke detectors hardwired & interconnected.
5. All ADU & main CO detectors are hardwired.
6. All ADU (and main) bedroom windows are above grade,
minimum openable area 6.1 sq.ft., min openable
width 20", openable height 44".
7. Each ADU room has individually -controlled
electric heater.
8. New partitions for separation are marked "NEW",
everything else is existing.
RESUB
Jul 25 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
72x48 72x48
Slider Slider 30x80 (6' slider)
Z
bedroom bedroom
Living Room
0 fl 0
SD j] SD
fireplace
O
SD&CO
light
kitchen
2 of 32x80 `-
LEVEL 2
O 32x80
SD
36x80 Scale 1/8" = 1'
bedroom
x `v
c N
Garage
Project: ADU within existing building structure
at 403 12th PI N, Edmonds, WA 98020
Contact: Tanya Mead, manager.svp@gmail.com
ADU will have a separate address
RESUB
Jul 25 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT