REVIEWED BLD2024-0533 Energy Code Compliance Form4/22/24, 11:56AM waenergycodes.com/print_ project _summary _form. php?k=Y29tYm9fdGZ2X3BOPWxOZ 19zY29wZV9uZXdfaW50ZXJpb31INONwZF9hbHRlcmFOaW9uX2dOXzUwJnRmdj1sdGdfc2N...
LIGHTING COMPLIANCE SUMMARY
2021 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: 02024 NEEA, All rights reserved
Project Title
South Hill Pain and Wellness - 2021 WSEC
For Building Department Use: M
C E I V E Gate • Apr 22, 2024
FN
Project Address
21701 76th Ave W
Suite 104
REVIEWED
Project & Applicant
Edmonds, WA 98026
BY
Apr 22 2024
Applicant Name
Amanda Promisloff
Information
CITY OF EDMONDS
CITY OF EDMONDS B L D2024-0533
Applicant Phone
425-599-4467
VELOPMENT SERVICES
DEPARTMENT
Applicant Email
apromislofi@tgbarchitects.com
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
General Occupancy
All Commercial
General Building Use Type
Office, Medical
Building Cond. Floor Area
1,500
New Building or
Project Cond. Floor Area
1,500
General Project Types
Alteration
Addition
Alteration
LihtinScoe
gg p
Interior Lighting
Floors Above Grade
3
Compliance Method
General Prescriptive
Lighting Scope
Lighting Project
Description
remodel of existing suite located on the 1st floor of he building including reception, waiting, exam rooms, work areas, utility rooms, and a break room.
Lighting Compliance
Project Type
Interior / Exterior
(Interior includes both interior
Luminaire Replacement Scope
Compliance Method
LPA Calculation
Compliance
Scope
P
&parking)
Adjustment
I
Verification
and Method
Alteration
Interior Lighting
20% or more replaced
Space by space
No Calculation Adjustments allowed
COMPLIES
Additional Energy
Efficiency (AEC)
No lighting or electrical additional energy efficiency
Load Management (LDM) Measures Included
No lighting or electrical load management measures included in project
Measures Included
measures included in project
Project Title South Hill Pain and Wellness - 2021 WSEC Date Apr 024
Lighting Power Calculation ALTERATION -INTERIOR LIGHTING (20% or more replaced) Compliance Verification COMPLIES
Compliance Method Space by space LPA Calculation Adjustment none
Interior Lighting Power Allowance - Space by Space
General Space Type
Specific Space Type
Gross Interior Area (SF)
LPA (Watts/SF)
Total Watts Allowed
(SF x LPA x 1)
Total Proposed Watts
(LPD + Display LPD)
Compliance Status
Lobby
General
215
0.84
181
Restroom
General
63
0.63
40
Storage room
50-100 sf
75
0.38
29
Healthcare facility
Corridor
151
0.71
107
Healthcare facility
Exam/treatment room
443
1.40
620
Healthcare facility
Lounge/breakroom
89
0.42
37
Healthcare facility
Nurse station
31
1.17
36
Proposed Total LPD
668
Totalsl
1,050
668
COMPLIES
Proposed Lighting Power Density
Watts or
Total Watts
Fixture Type
Fixture ID
Quantity of
Wattage Limit
Total Linear
Watts per Linear
Proposed
Fixtures (#F)
per Fixture
Feet (LF)
Foot (WpLF)
(#F x WpF) or
(WpF)
(LF x WpLF)
Individual Fixtures
Direct / indirect pendant
I LED Pendent
2
9
18
Troffer
LED 2x4
1 16
32
1
1
507
Recessed downlight
LED Downlight
1 7
17
1
1
119
https://waenergycodes.com/print_project _summary _form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3l l NONwZF9hbH Rlcm FOaW9uX2dOXzUwJnRmdj 1 sdGdfc2NvcGVfbmV3X2... 112
4/22/24, 11:56AM waenergycodes.com/print_project _summary _form. php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3iINONwZF9hbHRIcmFOaW9uX2dOXzUwJnRmdj1sdGdfc2N...
Wall-mountedl Lighted Mirror 1 24 1 24
Proposed Total LPD 668
Project Title
South Hill Pain and Wellness - 2021 WSEC
Da a
Apr 22, 2024
Proposed Fixtures Details
ALTERATION -INTERIOR LIGHTING (20% or more replaced)R
E CTN
Fixture Type/Application
Fixture ID
Location in Documents
Lamp Type
r -to-Remain
Individual FixturesBI02024-0533
Direct / indirect pendant
LED Pendent
Lobby
LED
DEVELOPMENT SEId�fMS
Fixture Description:
Are these fixtures located wit1RhPa &ytCl"tTzone?:
Do these fixtures require specific application lighting controls?:
Troffer
LED 2x4 All LED
New
Fixture Description:
Are these fixtures located within a daylight zone?:
Do these fixtures require specific application lighting controls?:
Recessed downlight
LED Downlight Hallway, storage, and toilet LED
New
Fixture Description:
Are these fixtures located within a daylight zone?:
Do these fixtures require specific application lighting controls?:
Wall -mounted
Lighted Mirror Toilet LED
New
Fixture Description:
Are these fixtures located within a daylight zone?:
Do these fixtures require specific application lighting controls?:
https://waenergycodes.com/print_project _summary _form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3llNONwZF9hbHRIcmFOaW9uX2dOXzUwJnRmdjl sdGdfc2NvcGVfbmV3X2... 212