OLD BLD2024-0847+Interior_Lighting_Summary+6.18.2024_2.05.51_PM+43300886/18/24, 2:01 PM waenergycodes.com/print_ project_summary_ form. php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3liNONwZF9hbHRlcmFOaW9uX2dOXzUwJnRmdj1sdGdfc2Nv...
LIGHTING COMPLIANCE SUMMARY
2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: 02024 NEEA, All rights reserved
Project & Applicant
Information
Project Title
Healthcare Realty Transformation Care Network - 2018 WSEC
For Building Department Use: Date: Jun 18, 2024
Project Address
WA
Applicant Name
Amanda Promisloff
Applicant Phone
425-599-4467
Applicant Email
apromisloff@tgbarchitects.com
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
General Occupancy
All Commercial
General Building Use Type
Office, Medical
Building Cond. Floor Area
4,790
General Project Types
Alteration
New Building or
Addition
Lighting Scope
Alteration
LihtinScoe
gg p
Interior Lighting
Project Cond. Floor Area
4,790
Floors Above Grade
3
Compliance Method
General Prescriptive
Lighting Project
Description
Lighting Compliance
Project Type
Interior / Exterior
(Interior includes interior
Luminaire Replacement Scope
Compliance Method
LPA Calculation
Compliance
Scope
aparking)
Adjustment
Adjustment
Verification
and Method
Alteration
Interior Lighting
50% or more replaced
Space by space
No Calculation Adjustments allowed
COMPLIES
Projec Healthcare Realty Transformation Care Network - 2018 WSEC un 18, 2024
Lighting Power Calculation ALTERATION -INTERIOR LIGHTING (50% or more replaced) Compliance Verification COMPLIES
Compliance Method Space by space LPA Calculation Adjustment none
Interior Lighting Power Allowance - Space by Space
General Space Type
p YP
Specific Space a
p p Type
Gross Interior Area SF
( )
LPA Watts/SF
(
Total Watts Allowed
(SF x LPA x 1)
Total Proposed Watts
(LPD + Display LPD)
Compliance Status
p
Corridors
General
70
0.41
29
Lobby
General
131
0.84
110
Office
Enclosed less than 250 sf
103
0.74
76
Office
Enclosed less than 250 sf
103
0.74
76
Office
Enclosed less than 250 sf
1 88
0.74
65
Office
Enclosed less than 250 sf
89
0.74
66
Office
Enclosed less than 250 sf
100
0.74
74
Office
Enclosed less than 250 sf
100
0.74
74
Office
Enclosed less than 250 sf
98
0.74
73
Office
Enclosed less than 250 sf
103
0.74
76
Office
Enclosed less than 250 sf
103
0.74
76
Office
Enclosed less than 250 sf
145
0.74
107
Office
Enclosed less than 250 sf
109
0.74
81
Office
Enclosed less than 250 sf
96
0.74
71
Office
Enclosed less than 250 sf
95
0.74
70
Office
Enclosed less than 250 sf
95
0.74
70
Office
Enclosed less than 250 sf
94
0.74
70
Office
Enclosed less than 250 sf
89
0.74
66
Office
Enclosed less than 250 sf
86
0.74
64
Office
Enclosed less than 250 sf
110
0.74
81
Office
Enclosed less than 250 sf
99
1 0.74
73
ELI
hftps://waenergycodes.com/print_project _summary _form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3l l NONwZF9hbH Rlcm FOaW9uX2dOXzUwJnRmdj 1 sdGdfc2NvcGVfbmV3X2... 112
6/18/24, 2:01 PM waenergycodes.com/print_ project _summary _form. php?k=Y29tYm9fdGZ2X3B0PWx0Z19zY29wZV9uZXdfaW50ZXJpb3llNONwZF9hbHRIcmFOaW9uX2dOXzUwJnRmdj1sdGdfc2Nv...
Office
Enclosed less than 250 sf
100
0.74
74
Restroom
General
77
0.63
49
Restroom
General
55
0.63
35
Restroom
General
79
0.63
50
Seating area
306
0.23
70
Storage room
Less than 50 sf
1 35
0.51
18
Storage room
Less than 50 sf
23
0.51
12
Storage room
Less than 50 sf
23
0.51
12
Healthcare facility
Corridor
62
0.71
44
Healthcare facility
Corridor
575
0.71
408
Healthcare facility
Corridor
179
0.71
127
Healthcare facility
Corridor
155
0.71
110
Healthcare facility
Exam/treatment room
69
1.40
97
Healthcare facility
Exam/treatment room
118
1.40
165
Healthcare facility
Exam/treatment room
164
1.40
230
Healthcare facility
Lounge/breakroom
183
0.42
77
Healthcare facility
Patient room
146
0.68
99
Proposed Total LPD
2,688
Totals
3,224
2,688
COMPLIES
Proposed Lighting Power Density
Fixture Type
Fixture ID
Quantity of
Fixtures (#F)
Watts or
Wattage Limit
per Fixture
(WpF)
Total Linear
Feet (LF)
Watts per Linear
Foot (WpLF)
Total Watts
Proposed
(#F x WpF) or
(LF x WpLF)
Individual Fixtures
Troffer
2x4
60
32
1,920
Troffer
2x2
26
1 27
1
1
702
Recessed downlight
Recessed LED
1 6
11
66
Proposed Total LPD
2,688
Project Title
Healthcare Realty Transformation Care Network - 2018 WSEC ate
Jun 18, 2024
Proposed Fixtures Details
ALTERATION - INTERIOR LIGHTING (50% or more replaced)
Fixture Type/Application
Fixture ID
Location in Documents Lamp Type
New or Existing -to -Remain
Individual Fixtures
Troffer
2x4
301, 318, 316, 321, 331, 333, 335, 337, 339, 341, 343, 345, 347, 362, 361, 352, 350, 348, 346, 344, LED
New
Fixture Description:
Are these fixtures located within a daylight zone?:
Do these fixtures require specific application lighting controls?:
Troffer
2x2 1 300, 315, 310, 320, 330, 360 LED
New
Fixture Description:
Are these fixtures located within a daylight zone?:
Do these fixtures require specific application lighting controls?:
Recessed downlight
Recessed LED T 317, 338, 349 LED
New
Fixture Description:
Are these fixtures located within a daylight zone?:
Do these fixtures require specific application lighting controls?:
https://waenergycodes.com/print_project _summary _form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3llNONwZF9hbHRIcmFOaW9uX2dOXzUwJnRmdjl sdGdfc2NvcGVfbmV3X2... 212