Loading...
REVIEWED BLD2024-0847+Interior_Lighting_Summary+7.30.2024_9.37.00_AM+44093547/30/24, 9:34AM waenergycodes.com/print_project_summary_form.php?k=aWQ9Mjc4MDgmZnZpPTIzJmN0aT0=&print=1 BLD2024-0847 TING COMPLIANCE SUMMARY 2021 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2024 NEEA, All rights reserved Project & Applicant Information Project Title Healthcare Realty Transformation Care Network - 2021 WSEC For Building Department Use: I Date: M 30, 2024 REVIEWED BY RE S U B CITY O F E D M O N DS Jul 30 2024 Project Address WA Applicant Name Amanda Promisloff Applicant Phone 425-599-4467 Applicant Email apromisloff@tgbarchitects.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at c DEVE DEPARTMENRVICES General Occupancy All Commercial General Building Use Type Office, Medical Building Cond. Floor Area 4,790 General Project Types Alteration New Building or Addition Lighting Scope Alteration Lighting Scope Interior Lighting Project Cond. Floor Area 4,790 Floors Above Grade 3 Compliance Method General Prescriptive Lighting Project Description Lighting Compliance Project Type Interior / Exterior (Interior includes both interior Luminaire Replacement Scope Compliance Method LPA Calculation Compliance Scope P &parking) Adjustment Verification and Method Alteration Interior Lighting 20% or more replaced Space by space No Calculation Adjustments allowed COMPLIES Additional Energy Efficiency (AEC) No lighting or electrical additional energy efficiency Load Management (LDM) Measures Included No lighting or electrical load management measures included in project Measures Included measures included in project Project Title Healthcare Realty Transformation Care Network - 2021 WSEC Date Jul 30, 2024 Lighting Power Calculation UFALTERATION - INTERIOR LIGHTING (20% or more replaced) Compliance Verification COMPLIES Compliance Method Space by space LPA Calculation Adjustment I none Interior Lighting Power Allowance - Space by Space General Space Type Specific Space Type Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts (LPD + Display LPD) Compliance Status Corridors General 62 0.41 25 Corridors General 154 0.41 63 Corridors General 180 0.41 74 Corridors General 575 0.41 236 Corridors General 70 0.41 29 Office Enclosed < 250 sf 131 0.74 97 Office Enclosed < 250 sf 103 0.74 76 Office Enclosed < 250 sf 103 0.74 76 Office Enclosed < 250 sf 89 0.74 66 Office Enclosed < 250 sf 100 0.74 74 Office Enclosed < 250 sf 100 0.74 74 Office Enclosed < 250 sf 98 0.74 73 Office Enclosed < 250 sf 103 0.74 76 Office Enclosed < 250 sf 103 0.74 76 Office Enclosed < 250 sf 145 0.74 107 Office Enclosed < 250 sf 109 0.74 81 Office Enclosed < 250 sf 1 96 0.74 71 Office Enclosed < 250 sf I i 95 0.74 70 https://waenergycodes.com/print_ project_summary_form.php?k=aWQ9Mjc4MDgmZnZpPTIzJmN0aT0=&print=1 1/2 7/30/24, 9:34 AM waenergycodes.com/print_ project_summary_form.php?k=aWQ9Mjc4MDgmZnZpPTIzJmN0aT0=&print=1 Office Enclosed < 250 sf 95 0.74 70 Office Enclosed < 250 sf 93 0.74 69 Office Enclosed < 250 sf 89 0.74 66 Office Enclosed < 250 sf 86 0.74 64 Office Enclosed < 250 sf 110 0.74 81 Office Enclosed < 250 sf 1 99 0.74 73 Office Enclosed < 250 sf 100 0.74 74 Restroom General 77 0.63 49 Restroom General 55 0.63 35 Restroom General 79 0.63 50 Seating area 305 0.23 70 Storage room Less than 50 sf 35 0.51 18 Storage room Less than 50 sf 23 0.51 12 Storage room Less than 50 sf 23 0.51 12 Healthcare facility Exam/treatment room 146 1.40 204 Healthcare facility Exam/treatment room 69 1 1.40 97 Healthcare facility Exam/treatment room 118 1.40 165 Healthcare facility Exam/treatment room 164 1.40 230 Healthcare facility Lounge/breakroom 183 0.42 77 Proposed Total LPD 2,688 Totals 2,959 2,688 COMPLIES Proposed Lighting Power Density Fixture Type Fixture ID Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Troffer LED 2x2 26 27 702 Troffer LED 2x4 60 32 1 1,920 Recessed downlight LED Downlight 6 11 1 66 Proposed Total LPD 2,688 Project Tit a Healthcare Realty Transformation Care Network - 2021 WSEC Date Ju130, 2024 Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (20% or more replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Troffer LED 2x2 300, 310, 315, 320, 330, 360 LED New Fixture Description: Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Troffer LED 2x4 1 301, 318, 316, 321, 331, 333, 335, 337, 339, 341, 345, 347, 362, 361, 352, 350, 348, 346, 344, 342, LED New Fixture Description: Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Recessed downlight LED Downlight 1 317, 338, 349 LED New Fixture Description: Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: https://waenergycodes.com/print_ project_summary_form.php?k=aWQ9Mjc4MDgmZnZpPTIzJmN0aT0=&print=1 2/2