APPROVED BLD FIR-RESUB1 BLD2022-1279+Architectural_Plan+5.17.2023_3.09.22_PM+3552079GENERAL NOTES
GENERAL REQUIREMENTS
ALL WORK SHALL COMPLY WITH THE 2018 EDITION OF THE INTERNATIONAL BUILDING CODE (STRUCTURAL DESIGN),
INTERNATIONAL RESIDENTIAL CODE (ORDINANCE), MOST RECENT EDITION OF THE UNIFORM PLUMBING CODE,
INTERNATIONAL MECHANICAL CODE, NATIONAL ELECTRIC CODE, WASHINGTON STATE ENERGY CODE, ANY STATE
AND LOCAL AMENDMENTS, AND ANY APPLICABLE LAND USE CODE.
THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR DEVELOPING CONSTRUCTION DETAILS NECESSARY TO
CONSTRUCT A WEATHER TIGHT, DURABLE BUILDING. ALL FLASHING, WEATHERPROOFING, ROOFING AND
WATERPROOFING DETAILS AND CONSTRUCTION OF THESE DETAIL ASSEMBLIES ARE THE FULL AND COMPLETE
RESPONSIBILITY OF THE OWNER/BUILDER AND THESE DETAILS SHALL BE CONSTRUCTED PER MANUFACTURER
REQUIREMENTS, BUILDING CODE REQUIREMENTS AND ACCEPTED INDUSTRY STANDARDS FOR PERFORMANCE.
THE DESIGNER HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION SERVICES OR
CONSTRUCTION OBSERVATION SERVICES FOR THIS PROJECT AND IS NOT LIABLE OR RESPONSIBLE FOR
DETERMINING ADEQUACY OF CONSTRUCTION OF BUILDING ENVELOPE OR DETAILS. THE OWNER/BUILDER SHALL
BE RESPONSIBLE FOR INSPECTING AND VERIFYING THAT ALL FLASHING, WEATHERPROOFING, ROOFING AND
WATERPROOFING DETAILS ARE BUILT CORRECTLY AND MEET OWNER/BUILDER'S APPROVAL BEFORE BEING
COVERED BY SUBSEQUENT CONSTRUCTION WORK. USE OF THESE PLANS BY ANYONE OTHER THAN THE
INTENDED OWNER/BUILDER IS NOT PERMITTED.
ANY REDUNDANCY BETWEEN THESE NOTES AND S-SHEETS THE S-SHEETS SHALL SUPERSEDE.
SITE WORK
1. BACKFILL FOUNDATION DRAIN AT PERIMETER OF BUILDING WITH COURSE GRANULAR FILL. (1 1/2-3/8
CLEAN WASHED ROCK WITH MIN. 12" WIDE BLANKET EXTENDING TO FINISHED GRADE.) PROTECT DRAIN
TILE AND WATERPROOFING.
2. ROUGH GRADING SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. TRENCH TO ELEVATIONS
BELOW FROST LINE FOR STORM DRAINS, WATER LINES, SEWERS, AND IRRIGATION SLEEVES.
3. PROVIDE PERFORATED PLASTIC PIPE FOUNDATION DRAINS WHERE SHOWN IN DRAWINGS. CONNECT TO
ROOF AND STORM WATER SYSTEM. IN JURISDICTIONS REQUIRING SEPARATE ROOF DRAIN LINES,
PROVIDE TIGHT LINE CONNECTED TO ROOF DRAINS IN ADDITION TO PERFORATED DRAIN LINES.
4. ROCKERIES AND RETAINING WALLS SHALL BE DESIGNED BY A LICENSED ENGINEER AND INSTALLED PER
APPLICABLE CODE.
MECHANICAL
1. PLUMBING SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT, EXPERIENCED PLUMBER AND
IN ACCORDANCE WITH THE UNIFORM PLUMBING CODE AND LOCAL CODES.
2. HVAC SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED MECHANICAL
CONTRACTOR IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE, 2018 IRC, AND LOCAL CODES.
PROVIDE DOCUMENTATION OF FURNACE A.F.U.E. DUCTWORK INSULATION SHALL CONFORM TO THE
WASHINGTON STATE ENERGY CODE. WHEN INSTALLED IN GARAGE, HEATING UNITS SHALL BE PLACED SUCH
THAT ALL PILOT LIGHTS, BURNERS, HEATING ELEMENTS, OR SWITCHES ARE LOCATED A MIN. OF 18" ABOVE
THE GARAGE FLOOR.
THERMAL AN D MOISTU RE
1. INSULATION REQUIREMENTS SHALL MEET OR EXCEED THE LATEST EDITION OF THE WASHINGTON ENERGY
CODE OR ENERGY CODE ADOPTED BY THE LOCAL JURISDICTION. INSULATION REQUIREMENTS SHALL BE
SHOWN ON PLANS OR ON A SEPARATE ENERGY CALCULATION SHEET.
2. APPLY 1 COAT (MIN) HEAVY BODIED ASPHALT BITUMINOUS DAMPPROFING TO EXTERIOR OF FOUNDATION
WALLS, FROM FOOTING TO FINISHED GRADE AT FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE
INTERIOR SPACES AND FLOORS BELOW GRADE.. (R406.1)
3. APPLY APPROPRIATE WATER REPELLENTS TO ANY MASONRY, CEMENT, PLASTER, OR STUCCO PER
MANUFACTURER'S INSTRUCTIONS.
4. PROVIDE 6 MIL BLACK POLYETHYLENE VAPOR BARRIER IN ALL CRAWLSPACE AREAS, LAPPED AT ALL SPLICES
AND OVER FOOTINGS.
FINISHES
GARAGE CEILINGS BENEATH HABITABLE SPACES SHALL BE COVERED WITH 5/8" TYPE "X" GYPSUM WALL BOARD.
GARAGE CEILINGS BENEATH ATTIC OR NON LIVING SPACE SHALL BE COVER WITH 5/8" GYPSUM WALL BOARD.
WALLS AND STRUCTURE SEPARATING RESIDENTIAL AND GARAGE SPACES SHALL BE COVERED WITH 1/2" GYPSUM
WALL BOARD. ALL GARAGE GYPSUM WALLBOARD SHALL HAVE JOINTS FIRETAPED WITH NAILS SET AND
COMPOUNDED. ALL OTHER WALLS SHALL RECEIVE 1/2" GYPSUM WALLBOARD. CEILINGS WITH JOISTS/ TRUSS
SPACES GREATER THAN 16" SHALL RECEIVE 5/8" GYPSUM WALLBOARD OR 1/2" GYPSUM CEILING BOARD. WALLS
SURROUNDING TUBS OR SHOWERS SHALL BE COVERED WITH WATER-RESISTANT GYPSUM WALL BOARD. WATER-
PROOF SURFACE TO A HEIGHT OF 72" ABOVE ADJACENT FLOOR. ANY CEMENT PLASTER OR STUCCO SHALL BE
INSTALLED IN ACCORDANCE WITH NORTHWEST WALL AND CEILING BUREAU RECOMMENDATIONS FOR MATERIALS,
BACKING, LATH, APPLICATION TECHNIQUES, AND FINISHES.
ELECTRICAL
SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED ELECTRICAL CONTRACTOR IN
ACCORDANCE WITH MOST CURENT STATE AND LOCAL ELECTRICAL CODE. ELECTRICAL SCHEMATICS PROVIDED IN
THIS SET OF PLANS ARE FOR REFERENCE LAYOUT ONLY.
FIRESTOPPING
FIRESTOPPING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND
HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND
THE ROOF SPACE. FIRESTOPPING SHALL BE PROVIDED IN WOOD FRAME CONSTRUCTION IN THE FOLLOWING
LOCATIONS:
1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES NOT TO EXCEED
10'-0" HORIZONTALLY, AND AT THE CEILING AND FLOOR LEVEL.
2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR
AT SOFFITS, DROP CEILINGS, COVE CEILINGS, ETC.
3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND WALL
CAVITIES IN LINE WITH STRINGERS.
4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS AND FIREPLACES AT CEILING AND FLOOR LEVEL,
WITH NON-COMBUSTABLE MATERIALS.
MISCELLANEOUS
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC. IN THE FIELD PRIOR TO PROCEEDING.
2. VERIFY SIZE AND LOCATION OF ALL OPENINGS IN THE FLOOR, ROOF, AND WALL WITH MECHANICAL AND
ELECTRICAL WORK.
3. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH (R314) SMOKE DETECTORS TO BE HARD WIRED AND
INTERCONNECTED. (R314.4, R314.5). A SMOKE DETECTOR SHALL BE INSTALLED IN EACH SLEEPING ROOM
AND OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. (R314) CARBON
MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE EACH SEPARATE SLEEPING AREA AND IN THE VICINITY
OF THE BEDROOMS. (R315)
4. KITCHEN RANGE, DRYER, BATH AND LAUNDRY ROOM VENTILATION DUCTS SHALL TERMINATE OUTSIDE THE
BUILDING AND BE EQUIPPED WITH BACK DRAFT DAMPERS.
5. EXTERIOR OPENINGS TO THE WEATHER SHALL BE FLASHED AND COUNTER -FLASHED IN SUCH A MANNER AS
TO MAKE THEM WATERPROOF. ROOF FLASHING PER R903.
6. GUARDRAILS TO BE A MIN. OF 36" ABOVE FINISH FLOOR. (R312) (EXCEPTIONS TO COMMERCIAL PER I.B.C.)
7. OPEN GUARDRAILS TO HAVE INTERMEDIATE RAILS OR PICKETS PLACED SUCH THAT A SPHERE 4" IN
DIAMETER CANNOT PASS THROUGH.
8. BEDROOM EMERGENCY EGRESS WINDOWS MUST HAVE A MIN. NET CLEAR OPENING OF 5.7 S0. FT. MINIMUM
NET CLEAR OPENABLE WIDTH OF 20" AND MIN. NET CLEAR OPENING HEIGHT OF 24". MAX. FINISHED HEIGHT
OF 44" FROM FINISHED FLOOR TO BOTTOM OF CLEAR OPENING (R310.1).
FIRE SPRINKLERS
A RESIDENTIAL FIRE SPRINKLER SYSTEM WILL BE INSTALLED PER CITY OF EDMONDS FIRE CODE.
DEFERRED SPRINKLER PLANS BY OTHERS WILL BE SUBMITTED AT TIME OF SPRINKLER PERMIT APPLICATION.
AREA CALCULATIONS
HEATED AREAS SQUARE FOOTAGE
2ND FLOOR 734
MAIN FLOOR 1844
TOTAL 2578
NON -HEATED AREAS SQUARE FOOTAGE
GARAGE (1ST FLOOR)
461
LAWN GARAGE
80
BASEMENT STORAGE RM.
300
COVERED ENTRY
60
COVERED PATIO
153
DRAWING INDEX
SHEET NO. DESCRIPTION
AO
SITE PLAN
Al
COVER SHEET, INDEX, GENERAL NOTES
A2
ENERGY CALCULATIONS
A3
ELEVATIONS
A4
ELEVATIONS
A5
BASEMENT FLOOR PLAN
A6
1ST FLOOR PLAN
A7
2ND FLOOR PLAN
A8
BUILDING SECTIONS AND MISC. DETAILS
A9
BUILDING SECTION/DETAIL
S1
STRUCTURAL NOTES/SCHEDULES
S2
SHEARWALL &HOEDOWN LOCATIONS
S3
FOUNDATION PLAN
S4
MAIN FLOOR FRAMING
S5
2ND FLOOR FRAMING
ROOF PLAN
S6
S7
STRUCTURAL DETAILS
SYMBOL LEGEND
OO
CARBON MONOXIDE DETECTOR
INTERCONNECTED 110v w/ BATTERY BACKUP
c.o.
CAN BE COMBINED w/ S.D.
O
SMOKE DETECTOR
INTERCONNECTED 110v w/ BATTERY BACKUP
s.o.
O
EXHAUST FAN (VENT TO OUTSIDE)
OKEYNOTE
101
DOOR SCHEDULE SYMBOL
1i
WINDOW SCHEDULE SYMBOL
REVISION- SEE DESCRIPTION IN
TITLE BLOCK
SIM
DETAIL SYMBOL
1 �
SIMILAR DETAIL
101
DETAIL N0.
—
SHEET N0.
SIM
1 �
BUILDING CROSS SECTION
�A101�
DETAIL NO.
SHEET N0.
Room name � ROOM NAME
� Know what's belOW.
STATE LAW REQUIRES THAT YOU CALL BEFORE YOU DIG TO
Call before you dig. LOCATE ALL UNDERGROUND UTILITIES.
GOODNIGHT &
FELLOWS RESIDENCE
J3'1ALOHA STREET, EDMONDS, WA 98020
741
OBTAIN ELECTRICAL
ALL WORK SUBJECT
APPROVED
PERMIT FROM
TO FIELD
PLANS MUST BE
STATE LABOR &
INSPECTION FOR
INDUSTRIES
CODE COMPLIANCE
ON JOB SITE
j',InterconnectedSmokeAlarmsAreARequirement�' � SEPARATE PLUMBING PERMIT
OfThisPermitlnAccordanceWithR314.2.2 �_� � REQUIRED FOR THIS PROJECT. I
..�;_._�
City Of Edmonds
Building Department
Work
Address 741 ALOHA ST
Owner GOODNIGHT &FELLOWS
------------ ------------
------------ ------------------
Approved Date 6/21 /2023
Building Official �P�%lf�it ��OOfytj
Permit Number BLD2022-1279
Approved
DFM CMr�s Burt
South County Fire
Date: 06/09/2023
06-09-2023
REVISION PLAN REVIEW
NOTES: APPROVED WITH CONDITION:
A RESIDENTIAL SPRINKLER SYSTEM IS
REQUIRED. A RECOMMENDED
FLOW -THROUGH DESIGN WILL MEET
SPECIFICATIONS AND REDUCE
EQUIPMENT AND CONTINUAING
MAINTENANCE REQUIRMENTS.
PROVIDE A MINIMUM COMBINATION
WATER SERVICE OF ONE INCH (1")
METER AND ONE AND ONE HALF (1 1/2")
SERVICE LINE OR SHOW THAT THE
DOMESTIC AND FIRE PROTECTIONS
NEEDS CAN BE MET WITH A SMALLER
SERVICE.
DFM BURT
REVISIONS
DATE - PAGES - CHANGES
REV1
REV2
REV3
REV4
REV5
V
Z N
[O
O
CO
Z Q �
a ��
U
� Y= �
Wd�
w��
���
O "��
J
U J��
���
M � �
Z �N�
W
� o °'
W m
J �
W �
O
u
C
�` %%_ +
c_:- �
' y� \ sar�.�.-
C
Hr �
�;,
p °' m� s N 'O � D N� N O O
Z m .- m N m m m° m°
NZ= p C O O �=� m U N QO_
N a m o:��m o r F `o o D � s U E m° o
=�¢�n o-°-o" � °.� `off � o=-
p0� o N� o o� �'° t6 m o� mt- y
O� 9 m "� '° c N�� .� � � N E y
a � � � o � N � o � � 9 0 � � n.m 8 0
OO J�r�m°aoO O-nm mp`��O
F �no y-�� aEim�oFE�`m
RESUB
W
May 17 2023
V
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Z
W
�
�
N
h
�
W
pC
�
H
t/�
t/�
�
�
O
O
N
J
J
J
�
�
a
W
W
a
H
H
Z
O
W
�
Z
�
Z
W
�
0
a
�
zo
0
0
W O
O cn
�a
J
O
V
Z
!�
V
�
O Q
n
�
�
�
C'7
N
(D
�
M
N
CO
�
c
a�
�
o
�
•-
�
�
a�
�
'�
a
a�
�
0
.�
o
�
E
T
m
�
L
o
c
�
m
�
�
�
.�
.�
�
�
Z
�
N
PROJECT NO.
210905
DESIGNED BY
TL
DRAWN BY
TL & RM
CHECKED BY
TL
SHEET NO.
PRINT DATE 5/12/2023 7:45:54 AM
R301 CLIMATE ZO N E
THIS PLAN IS DESIGNED FOR CLIMATE ZONE 5 AND MARINE 4 PER TABLE R301.1, 2018 WASHINGTON STATE
ENGERY CODE.
R402.2 FENESTRATION (PRESCRIPTIVE)
R402.3 Fenestration (Prescriptive). In addition to the requirements of Section R402, fenestration shall comply with Sections
R402.3.1 through R402.3.6.
R402.3.1 U-factor. An area -weighted average of fenestration products shall be permitted to satisfy the U-factor requirements.
R402.3.2 Glazed fenestration SHGC. An area -weighted average of fenestration products more than 50 percent glazed shall be
permitted to satisfy the SHGC requirements.
R402.3.3 Glazed fenestration exemption. Up to 15 square feet (1.4 m2) of glazed fenestration per dwelling unit shall be
permitted to be exempt from U-factor and SHGC requirements in Section R402.1.1. This exemption shall not apply to the U-
factoralternative approach in Section R402.1.3 and the total UA alternative in Section R402.1.4.
R402.3.4 Opaque door exemption. One side -hinged opaque door assembly up to 24 square feet (2.22 m2) in area is exempted
from the U-factor requirement in Section R402.1.1. This exemption shall not apply to the U-factor alternative approach in Section
R402.1.3 and the total UA alternative in Section R402.1.4
R404.1 LIGHTING EFFICACY
MIN. OF 75%OF LAMPS IN PERMANENTLY INSTALLED FIXTURES SHALL BE HIGH EFFICACY LAMPS.
M 1505 MECHANICAL VENTILATION
M1505.4 Whole -house mechanical ventilation system. Each dwelling unit shall be equipped with a ventilation system. The whole -house mechanical ventilation
systems shall be designed in accordance with Sections M1505.4.1 through M1505.4.4.
M1505.4.1 System design. The whole house ventilation system shall consist of one or more supply fans, one or more exhaust fans, or an ERV/HRV with
integral fans, associated ducts and controls. Whole -house mechanical ventilation system with supply and exhaust fans per Sections M1505.4.1.2, M1505.4.1.3,
M1505.4.1.4, and M1505.4.1.5. Local exhaust fans are permitted to serve as part of the whole house ventilation system when provided with the proper controls
per Section M1505.4.2. The systems shall be designed and installed to exhaust and/or supply the minimum outdoor airflow rates per Section M1505.4.3 as
modified by the whole house ventilation system coefficients in Section M1504.4.3.1 where applicable. The whole house ventilation system shall operate
continuously at the minimum ventilation rate determined per Section M1505.4.2 unless configured with intermittent off controls per Section M1505.4.3.2.
M1505.4.1.1 Whole house system component requirements. Whole house ventilation supply and exhaust fans specified in this section shall have a minimum
efficacy as prescribed in the Washington State Energy Code. Design and installation of the system or equipment shall be carried out in accordance with
manufacturers' installation instructions. Whole house ventilation fans shall be rated for sound at no less than the minimum airflow rate required by Section
M1505.4.3.1. Ventilation fans shall be rated for sound at a maximum of 1.0 sone. This sound rating shall be at a minimum of 0.1 in. w.c.
(25 Pa) static pressure in accordance with HVI procedures specified in Sections M1505.4.1.2 and M1505.4.1.3.
Exception: HVAC air handlers, ERV/HRV units, and remote mounted fans need not meet the sound requirements. To be considered for this exception, a
remote mounted fan must be mounted outside the habitable spaces, bathrooms, toilets, and hallways, and there must be at least 4 ft (1 m) of ductwork
between the fan and the intake grille.
The whole house supply fan shall provide ducted outdoor ventilation air to each habitable space within the residential unit.
Exception: Interior joining spaces provided with a 30 cfm whole house transfer fan or a permanent opening with an area of not less than 8 percent of the floor
area of the interior adjoining space but not less than 25 square feet do not require ducted outdoor ventilation air to be supplied directly to the space. Whole
house transfer fans shall meet the sone rating of Section M1505.4.1.1 and shall have whole house ventilation controls that comply with Section M1505.4.2.
M1505.4.1.2 Exhaust fans. Exhaust fans required shall be ducted directly to the outside. Exhaust air outlets shall be designed to limit the pressure difference to
the outside and equipped with backdraft dampers or motorized dampers in accordance with the Washington State Energy Code. Exhaust fans shall be tested
and rated in accordance with the airflow and sound rating procedures of the Home Ventilating Institute (HVI 915, HVI Loudness Testing and Rating Procedure,
HVI 916, HVI Airflow Test Procedure, and HVI 920, HVI Product Performance Certification Procedure as applicable). Exhaust fans required in this section may
be used to provide local ventilation. Bathroom exhaust fans that are designed for intermittent exhaust airflow rates higher than the continuous exhaust airflow
rates in Table M 1505.4.3(3) shall be provided with occupancy sensors or humidity sensors to automatically override the fan to the high speed airflow rate. The
exhaust fans shall be tested and the testing results shall be submitted and posted in accordance with Section M1505.4.1.6.
M1505.4.1.3 Supply fans. Supply fans used in meeting the requirements of this section shall supply outdoor air from intake openings in accordance with IMC
Sections 401.4 and 401.5. When designed for intermittent off operation, supply systems shall be equipped with motorized dampers in accordance with the
Washington State Energy Code. Supply fans shall be tested and rated in accordance with the airflow and sound rating procedures of the Home Ventilating
Institute (HVI 915, HVI Loudness Testing and Rating Procedure, HVI 916, HVI Airflow Test Procedure, and HVI 920, HVI Product Performance Certification
Procedure as applicable). Where outdoor air is provided by supply fan systems, the outdoor air shall be filtered. The filter shall be accessible for regular
maintenance and replacement. The filter shall have a Minimum Efficiency Rating Value (MERV) of at least 8.
M1505.4.1.4 Balanced whole house ventilation system. A balanced whole house ventilation system shall include both supply and exhaust fans. The supply and
exhaust fans shall have airflow that is within 10 percent of each other. The tested and balanced total mechanical exhaust airflow rate is within 10 percent or 5
cfm, whichever is greater, of the total mechanical supply airflow rate. The flow rate test results shall be submitted and posted in accordance with Section
M1505.4.1.7. The exhaust fan shall meet the requirements of Section M1505.4.1.2. The supply fan shall meet the requirements of Section M1505.4.1.3.
Balanced ventilation systems with both supply and exhaust fans in a packaged product, such as an ERV/HRV, shall meet the requirements of HVI 920, as
applicable. Intermittent dryer exhaust, intermittent range hood exhaust, and intermittent toilet room exhaust airflow rates above the residential dwelling or
sleeping unit minimum ventilation rate are exempt from the balanced airflow calculation.
M1505.4.1.5 Furnace integrated supply. Systems using space heating and/or cooling air handler fans for outdoor air supply distribution are not permitted.
Exception: Air handler fans shall have multispeed or variable speed supply airflow control capability with a low speed operation not greater than 25 percent of
the rated supply airflow capacity during ventilation only operation. Outdoor air intake openings must meet the provisions of Sections R303.5 and R303.6 and
must include a motorized damper that is activated by the whole house ventilation system controller. The motorized damper must be controlled to maintain the
outdoor airflow intake airflow within 10 percent of the whole house mechanical exhaust airflow rate. The flow rate for the outdoor air intake must be tested and
verified at the minimum ventilation fan speed and the maximum heating or cooling fan speed. The results of the test shall be submitted and posted in
accordance with Section M1505.4.1.7.
M1505.4.1.6 Testing. Whole -house mechanical ventilation systems shall be tested, balanced and verified to provide a flow rate not less than the minimum
required by Sections M1505.4.3 and M1505.4.4. Testing shall be performed according to the ventilation equipment manufacturer's instructions, or by using a
flow hood, flow grid, or other airflow measuring device at the mechanical ventilation fan's inlet terminals, outlet terminals or grilles or in the connected ventilation
ducts. Where required by the building official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by
the party conducting the test and provided to the building official and be posted in the dwelling unit per Section M1505.4.1.7.
M1505.4.1.7 Certificate. A permanent certificate shall be completed by the mechanical contractor, test and balance contractor or other approved party and
posted on a wall in the space where the furnace is located, a utility room, or an approved location inside the building. When located on an electrical panel, the
certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect label, or other required labels. The certificate shall list the flow
rate determined from the delivered airflow of the whole -house mechanical ventilation system as installed and the type of mechanical whole house ventilation
system used to comply with Section M1505.4.3.1.
M1505.4.2 System controls. The whole -house mechanical ventilation system shall be provided with controls that comply with the following:
1. The whole house ventilation system shall be controlled with manual switches, timers or other means that provide for automatic operation of the ventilation
system with ready access by the occupant.
2. Whole -house mechanical ventilation system shall be provided with controls that enable manual override off of the system by the occupant during periods of
poor outdoor air quality. Controls shall include permanent text or a symbol indicating their function. Recommended control permanent labeling to include text
similar to the following: "Leave on unless outdoor air quality is very poor." Manual controls shall be readily accessible by the occupant.
3. Whole house ventilation systems shall be configured to operate continuously except where intermittent off controls and sizing are provided per Section
M 1505.4.3.2.
M1505.4.3 Mechanical ventilation rate. The whole -house mechanical ventilation system shall provide outdoor air at a continuous rate as determined in
accordance with Table M1505.4.3(1) or Equation 15-1.
TABLE 1505.4.3 (1) WHOLE HOUSE MECHANICAL VENTILATION AIRFLOW RATES
FLOOR AREA
BEDROOMS
(SQ. FT.)
0-1
2
3
4
5 OR MORE
< 500
30
30
35
45
50
501-1000
30
35
40
45
50
55
55
1001-1500
3p
40
60
1501-2000
35
45
50
60
65
2001-2500
40
50
55
65
70
2501-3000
45
55
60
70
75
3001-3500
50
60
65
75
80
3501-4000
55
65
70
80
85
90
4001-4500
60
70
75
g5
4501-5000
65
75
80
90
95
TABLE 1505.4.3(3) INTERMITTENT OFF WHOLE HOUSE MECHANICAL VENTILATION RATE FACTORS (a,b)
RUN-TIME % IN EACH
4-HOUR SEGMENT
50% 66%
75% 100%
FACTOR
2
1.5
1.3
1.0
THIS PLAN USES AN INTERMITTENT WHOLE HOUSE VENTILATION SYSTEM WITH TIMER(s).
TOTAL HEATED FLOOR AREA = 2578 SQ. FT. BEDROOMS = 4
WHOLE HOUSE VENTILATION SIZE = 70 CFM X 2 (50% PER 4-HOUR) = 140 TOTAL CFM FAN(s) SIZE.
INTEGRATED FURNACE OUTSIDE AIR INTAKE WITH EXHAUST FANS AS NOTED IN PLAN .
MULTIPLE WHOLE HOUSE VENTILATION FANS TO BE INTERCONNECTED TO OPERATE SIMULTANEOUSLY.
2018 WASHINGTON STATE ENERGY CODE
MISC. ENERGY CODE NOTES
A permanent certificate shall be completed and posted on or within three feet of the electrical distribution panel by the
builder or registered design professional. The certificate shall be completed by the builder or registered design
professional and shall not cover or obstruct the visibility of the circuit directory label, service disconnect label or other
required labels. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls,
foundation (slab, below -grade wall, and/or floor) and ducts outside conditioned spaces; U-factors for fenestration and the
solar heat gain coefficient (SHGC) of fenestration, and the results from any required duct system and building envelope
air leakage testing done on the building. Where there is more than one value for each component, the certificate shall list
the value covering the largest area. The certificate shall list the types and efficiencies of heating, cooling and service
water heating equipment.
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes
per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).Where
required by the code official, testing shall be conducted by an approved third party. A written report of the results of
the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed
at any time after creation of all penetrations of the building thermal envelope.
Where the primary heating system is a forced -air furnace, at least one thermostat per dwelling unit shall be capable of
controlling the heating and cooling system on a daily schedule to maintain different temperature set points at different
times of the day. Specifics and Exceptions see SEC.
ALL DUCTWORK SHALL BE SEALED AND TESTED PER R403.2.2
WINDOW AND DOOR HEADERS SHALL BE INSULATED WITH R-10 RIGID INSULATION EXCEPT IN SITUATIONS
WHERE STRUCTURAL BEAM SIZE REQUIREMENTS OVERRIDE.
ALL APPLIANCES SHALL BE U.L. LISTED.
WHOLE HOUSE FANS
Whole house ventilation fans shall be installed so as to run simultaniously.
EXHAUST FANS
Exhaust fans to terminate at building exterior with clearances per SRC
M1506.2 (min. 3 ft to openings) and for clothes dryer vent terminations to be per M1502.3 (3 ft to Bldg. openings).
ALL FENESTRATION SHALL BE NFRC CERTIFIED.
tx6 TOP PLATES
.W.B.
.ID R-10 INSULATION
tLLED IN CAVITY BETWEEN
ER AND INTERIOR G.W.B.
ER PER PLAN
..,,.�OW, FINISH &TRIMS
PER MISC. DETAILS
HEADER INSULATION
PRESCRIPTIVE ENERGY CODE COMPLIANCE
2018 Washington State Energy Code -Residential
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Single Family -New &Additions (effective February 1, 2021) Version 1.0
These re uirements a I to all IRC buildin t es includin detached one- and two-famil
q pp Y g Yp g Y
dwellings and multiple single-family dwellings (townhouses).
Project Information Contact Information
737 Aloha Street, Edmonds, WA Brian Goodni ht
Instructions: This single-family project will use the requirements of the Prescriptive Path below and
incorporate the minimum values listed. Based on the size of the structure, the appropriate number of
additional credits are checked as chosen by the permit applicant.
Provide all information from the following tables as building permit drawings: Table R402.1-Insulation and
Fenestration Requirements by Component, Table R406.2 -Fuel Normalization Credits and 406.3 -Energy Credits.
Authorized Representative I I Date 04/15/2023
All Climate Zones (Table R402.1.1)
R-Value a U-Factor a
Fenestration U-Factorb n/a 0.30
Skylight U-Factorb n/a 0.50
Glazed Fenestration SHGC bje n/a n/a
Ceiling e 49 0.026
Wood Frame Wall g•h 21 int 0.056
Floor 30 0.029
Below Grade Wall `•h 10/15/21 int + TB 0.042
Slab d.t R-Value &Depth 10, 2 ft n/a
R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity that is less
a than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix
Table A101.4 shall not be less than the R-value specified in the table.
b .The fenestration U-factor column excludes skylights.
"10/15/21 +STB" means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on
the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at
c the interior of the basement wall. "10/15/21 +5T6" shall be permitted to be met with R-13 cavity insulation on
the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5T6"
means R-5 thermal break between floor slab and basement wall.
d R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1.
For single rafter- orjoist-vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth
e extends over the top plate of the exterior wall.
R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter
f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall
meet the requirements for thermal barriers protecting foam plastics.
For log structures developed incompliance with Standard ICC 400, log walls shall meet the requirements for
g climate zone 5 of ICC 400.
Int. (intermediate framing) denotes framing and insulation as described in Section A103.2.2 including standard
h framing 16 inches on center, 78% of the wall cavity insulated and headers insulated with a minimum of R-10
insulation.
Prescriptive Path -Single Family 2018 Washington State Energy Code-R
FENENSTRATION CALCULATIONS
VERTICAL GLAZING 367 SF
LESS EXEMPT GLAZING -00 SF
GLAZED DOORS PLUS OTHER
EXTERIOR DOORS 152 SF
TOTAL FENESTRATION: 519 SF
NOTE:
SEE SHEET A8 & A9 FOR
ADDITIONAL INSULATION
LOCATIONS AND DETAILS.
ENERGY CREDITS
OPTIONS
DESCRIPTION
HEATING
Combustion heating equipment meeting minimum federal
OPTION 1
efficiency standards for the equipment listed in Table
C403.3.2(4) or C403.3.2(5)
ENERGY
Prescriptive compliance is based on Table R402.1.1 with the
OPTION 1.3
following modifications:
Vertical fenestration U = 0.28
Floor R-38
Slab on grade R-10 perimeter and under entire slab
Below grade slab R-10 perimeter and under entire slab
ENERGY Compliance based on R402.4.1.2:
OPTION 2.1 Reduce the tested air leakage to 3.0 air changes per hour
maximum at 50 Pascals
ENERGY Energy Star rated (U.S. North) Gas or propane furnace with
OPTION 3.1 minimum AFUE of 95%
ENERGY Water heating system shall include one of the following:
OPTION 5.3 Energy Star rated gas or propane water heater with a minimum
UEF of 0.91
ENERGY For each 1200 kWh of electrical generation per housing unit
OPTION 6.1 provided annually by on -site wind or solar equipment a 1.0 credit
shall be allowed, up to 3 credits. Generation shall be calculated
as follows:
For solar electric systems, the design shall be demonstrated to
meet this requirement using the National Renewable Energy
Laborator calculator PVWATTs or a roved alternate b the
Y PP Y
code official.
Documentation noting solar access shall be included on the
plans.
CREDIT
0.5
0.5
1.0
1.0
3.0
TOTAL CREDITS 6.0
2018 Washington State Energy Code -Residential
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Single Family -New &Additions (effective February 1, 2021)
Each dwelling unit in a residential building shall comply
with sufficient options from Table R406.2 (fuel
normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of
credits. To claim this credit, the building permit drawings shall specify the option selected and the
maximum tested building air leakage, and show the qualifying
ventilation system and its control sequence
of operation.
1. Small Dwelling Unit: 3 credits
Dwelling units less than 1,500 sf in conditioned floor
area with less than 300 sf of fenestration area.
Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf.
2. Medium Dwelling Unit: 6 credits
All dwelling units that are not included in #1 or #3
3. Large Dwelling Unit: 7 credits
Dwelling units exceeding 5,000 sf of conditioned floor
area
4. Additions less than 500 square feet: 1.5 credits
All other additions shall meet 1-3 above
Before selecting your credits on this Summary table, review the
details in Table 406.3 (Single Family), on page 4.
Summary of Table
R406.2
Heating
Options Fuel Normalization Descriptions
Credits -select ONE
heating option User Notes
1 Combustion heating minimum NAECAb
0.0 0 Gas Radiant heat +solar
2 Heat pump`
1.0 ❑
3 Electric resistance heat only - furnace or zonal
-1.0 ❑
4 DHP with zonal electric resistance per option 3.4
0.5 ❑
5 All other heating systems
-1.0 ❑
Energy
Credits -select ONE
O tions Energy Credit Option Descriptions
energy option from each
P
cate or
1.1 Ix�0000l�t®o 00 � � ®oo
0.5 ❑
1.2 Efficient Building Envelope
1.0 ❑
1.3 Efficient Building Envelope
_
0.5 �
1.4 Efficient Building Envelope
1.0 ❑
1.5 Efficient Building Envelope
2.0 ❑
1.6 Efficient Building Envelope
3.0 ❑
1.7 Efficient Building Envelope
0.5 ❑
2.1 Air Leakage Control and Efficient Ventilation
0.5 �
2.2 Air Leakage Control and Efficient Ventilation
1.0 ❑
2.3 Air Leakage Control and Efficient Ventilation
1.5 ❑
2.4 Air Leakage Control and Efficient Ventilation
2.0 ❑
3.1a High Efficiency HVAC
1.0 � Gas boiler for radiant floor ht
3.2 High Efficiency HVAC
1.0 ❑
3.3a High Efficiency HVAC
1.5 ❑
3.4 High Efficiency HVAC
1.5 ❑
3.5 High Efficiency HVAC
1.5 ❑
3.6a High Efficiency HVAC
2.0 ❑
4.1
High Efficiency HVAC Distribution System
0.5
1.0
❑
❑
4.2
High Efficiency HVAC Distribution System
Prescriptive Path -Single Family 2018 Washington State Energy Code-R 2
HEATING SYSTEM SIZE
simple rteanng system s¢e: wasningcon Mace
This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA
Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads.
Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section,
some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at
energycode@energy.wsu.edu or (360) 956-2042 for assistance.
Project Information
Contact Information
GOODNIGHT RESIDENCE
BRIAN GOODNIGHT
EDMONDS, WA98020
Heating System Type: .All other Systems
O Heat Pump
To see detailed instructions for each section, place your cursor on the word "Instructions"
Design Temperature
Instructions
Design Temperature Difference (4T) 46
Edmonds
� J oT =Indoor (70 degrees) -Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area (sq ft)
2,578
Average Ceiling Height
Conditioned Volume
Instructions Average Ceiling Height (ft)
9.1 23,460
Glazing and Doors
U-Factor X Area = UA
Instructions
`u-o.ze
� 0.280 519 145.32
Skylights
Instructions
Insulation
Attic
U-Factor X Area = UA
0.50 0� ---
U-Factor X Area = UA
Instructions �R49
�
I 0.026 2,157 56.08
J
Single Rafter or Joist Vaulted Ceilings
U-Factor X Area UA
Instructions
L No Vaulted Ceilings in this project.
Ceilings in this project.
�
lVaulted
Above Grade Walls tree Figure tj
U-Factor X Area UA
Instructions
`R-21 Intermediate
�
I 0.056 3,645 204.12
Floors
U-Factor X Area UA
Instructions
0.025 1,882 47.05
I
R-38
�
Below Grade Walls tree Figure ��
U-Factor X Area UA
Instructions
`No Below Grade Walls in this project.
�
0.028 0�
J
Slab Below Grade tree Figure tj
F-Factor X Length UA
Instructions
Slab Below Grade in
�
0.303 0�
No this project.
Slab on Grade (see Figure +�
F-Factor X Length UA
Instructions
No Slab Grade in
�
---
1
on this project.
Location of Ducts
Instructions
Duct Leakage Coefficient
Conditioned Space
�
I 1.00
Sum of UA 452.57
Envelope Heat Load 20,818
Btu /Hour
Fiaure 1.
Sum of UA x oT
Air Leakage Heat Load 11,655
Btu /Hour
Volume x 0.6 x 4T x 0.018
Above Grade
Building Design Heat Load 32,473
Btu /Hour
�
Air leakage +envelope heat loss
Building and Duct Heat Load 32,473
Btu /Hour
Ducts in unconditioned space: sum of building heat loss x 1.10
Ducts in conditioned space: sum of building heat loss x 1
Maximum Heat Equipment Output 45,462
Btu /Hour
Building and duct heat loss x 1.40 for forced air furnace
Building and duct heat loss x 1.25 for heat pump
2018 Washington State Energy Code -Residential
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Single Family -New &Additions (effective February 1, 2021)
Summary of Table R406.2 (cont.)
Energy Credits -select ONE
Energy Credit Option Descriptions (cont.) energy option from User Notes
Options each category d
5.1d Efficient Water Heating 0.5 ❑
5.2 Efficient Water Heating 0.5 ❑
5.3 Efficient Water Heating 1.0 �
5.4 Efficient Water Heating 1.5 ❑
5.5 Efficient Water Heating 2.0 ❑
5.6 Efficient Water Heating 2.5 ❑
6.1e Renewable Electric Energy(3 credits max) 1.0 0 12,000 KW total unit
7.1 Appliance Package 0.5 ❑
Total Cred►t5 6.0 Calculate Total Clear Form
a. An alternative heating source sized at a maximum of 0.5 W/sf (equivalent) of heated floor area or 500 W,
whichever is bigger, may be installed in the dwelling unit.
b. Equipment listed in Table C403.3.2(4) or C403.3.2(5)
c. Equipment listed in Table C403.3.2(1) or C403.3.2(2)
d. You cannot select more than one option from any category EXCEPT in category 5. Option 5.1 may be combined
with options 5.2 through 5.6. See Table 406.3.
e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max.
See the complete Table R406.2 for all requirements and option descriptions.
f. Use the single radiobutton in the upper right of the second column to deselect radiobuttons in that group.
Please print only pages 1 through 3 of this worksheet for submission to your building official.
Prescriptive Path -Single Family 2018 Washington State Energy Code-R 3
(07/01/13J
U
Z N
Z Q E
Q � o
� Y = o,
C w���
C w �, °'
��
O "��
J
U J��
���
M � �
Z � O ,C
W � @
� o °E'
W m
� o
W �
H
Q
U
C
�/ +
� /�i`�` .G�
\\, � �,
`R� �
r A'
_� . � . ��.
II '�
C y
U voi aims_ � ads °'aoo
z} .L y0 N N C J N L N� p- �� V! O
oQ �`o '� q c0 °'r�� � � o d n�- .
c� '� o d F o p U E o �n c
FD-m o��mat.. �c��Y ay 4
00� o o.� 0 0 o c m `° m o� m£ N`
L L N T C
U �'od u�mcrn �L=m�NEv�
a W� Q E aui N� c i i m a o� d �- -° o
O W� U�� w o U o o c c'� 3� d y U
U��H c m u c-oU o. o.�m m0 a'� `o
111 O N U d Ul -O E N� N L O 'C
F Z O- O y�� N N i O F r= N O
RESUB
LJJ
May 17 2023
V
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Z
W
0
H
W
�
�
v I
O
O
N
J
J
J
�
�
o•
I.L
I.L
�
H
H
Z
O
W
�
Z
�
Z
It-
W
� �
0
a
z O
O
�
W O
Z O N
J
� �
�
3 � 0
O Q
M
n
�
(6
�
Cr)
N
�
N
�
M
N
�
N
�
c
a>
�
o
�
�
�
•-
�
�
a�
o
'�
-a
�
a>
0
.�
o
�
E:
T
m
;�
�,
L
�
�
�
�
.�
.�
�
�
Z
�
N
PROJECT NO.
210905
DESIGNED BY
TL
DRAWN BY
TL & RM
CHECKED BY TL
SHEET NO.
PRINT DATE 5/12/2023 7:46:20 AM
ELEVATION NOTES
PROVIDE METAL FLASHING OVER TOPS OF WINDOWS AND TOPS OF TRIMS DIRECTLY EXPOSED TO
WEATHER.
ROOFING MATERIAL, SIDING AND FLASHING SHALL BE INSTALLED PER MANUFACTURER'S
SPECIFICATIONS, INDUSTRY STANDARDS AND PER I.R.C.
PORCHES, BALCONIES, RAMPS OR RAISED SURFACES LOCATED MORE THAN 30" ABOVE THE FLOOR OR
GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 36" IN HEIGHT. OPEN SIDE OF STAIRS WITH A TOTAL
RISE OF MORE THAN 30" SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT MEASURED VERTICALLY
FROM THE NOSING OF THE TREADS. INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES SHALL BE
SPACED SUCH THAT A 4" SPHERE CANNOT PASS THROUGH. THE TRIANGLE OPENINGS FORMED BY THE
RISER, TREAD, AND BOTTOM OF RAIL SHALL BE SUCH THAT A 6" SPHERE CANNOT PASS THROUGH.
EXTERIOR STAIRS SHALL BE NOT LESS THAN 36"WIDE. HANDRAILS SHALL NOT PROJECT MORE THAN 4.5"
ON EITHER SIDE OF THE STAIRWAY AND MIN. CLEAR WIDTH AT OR BELOW THE HANDRAIL SHALL NOT BE
LESS THAN 31.5". MAX. RISER HEIGHT IS 7 3/4". MIN. TREAD DEPTH SHALL BE 10". A LANDING IS REQUIRED
AT TOP AND BOTTOM OF EACH STAIRWAY.
SITE ADDRESS SHALL BE VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY.
NUMBERS SHALL CONTRAST WITH BACKGROUND, BE ARABIC NUMBERS OR ALPHABETICAL LETTERS, BE A
MIN. OF 4" IN HEIGHT WITH A MIN. STROKE WIDTH OF 1/2". (R319.1)
Shingles
WeatherSealuowel-applied membrane
Step flashing taped and sealed
Kick -out flashing
� Kick -out and fascia
�� taped and sealed
Wall sheathing
KICKOUT FLASHING DETAIL
ELEVATION KEYNOTES
KEYNOTE NO. DESCRIPTION
E3
40+YEAR PRESIDENTIAL RANDOM CUT ARCHITECTURAL COMPOSITION ROOFING (IF PITCH
IS 3:12 OR LESS, INSTALL ROOFING OVER ICE AND WATER SHEILD.)
E5
CONTINUOUS ALUMINUM GUTTER ON 5/4x6 FASCIA
E9
FASCIA: 1x4 ON 5/4x10 (TYPICAL AT GABLE ENDS)
E14
HORIZONTAL BEVEL CEMENT BOARD SIDING PER BUILDER SPECS
E25
SLIMLINE METAL CORNER TRIM.
E44
TIMBER BEAM PER STRUCTURAL PLANS. STAIN OR PAINT PER OWNER SPECS.
E63
6" MINIMUM CLEARANCE ABOVE FINISHED GRADE OR PROVIDE TREATED MATERIAL PER
I RC317.
E66
CONCRETE LANDING AND STEPS PER IRC.
E70
HARDI PANEL SHEET SIDING WITH E-Z TRIM CHANNELS
E71
STONE VENEER PER MANUF. INSTALLATION SPECIFICATIONS o/P.T. PLYWOOD BOX FRAME
AND FRAMING o/ P.T. POST PER PLANS.
E81
EXTERIOR ENTRY DOOR w/TEMP. GLASS PER OWNER SPECIFICATIONS.
E83
DOUBLE SLIDING GLASS PATIO DOOR w/TEMP. GLASS
E84
INSULATED STEEL OVERHEAD GARAGE DOOR
E85
GARAGE DOOR -ALUMINUM OR STEEL FRAMNE w/ FROSTED TEMP. GLASS PANELS. MAKE
AND MODEL PER OWNER OR BUILDER.
E87
LOCKING DEADBOLD AT ENTRY DOOR.
E89
DOUBLE STORE DOOR w/ TEMP. GLASS.
0
0
z
w
U
H
Y
Q �
w
g
22
3, 112
- 0 5/8"
6' - 01 /2"
E83
SOLAR PANELS
7'-3
eni nn nnni�i c
� i
- 5 1 /2"
CV
0
SOUTH ELEVATION
ao
o
_ Max. Hei hg t �
106' -11 5/8" 1
Top of Ridge n
106' -1 1 /8"
2ND FLOOR PLATE �
102' - 3 1 /4" 1
_ 2ND FLOOR �
94' - 2 1 /4" 1
1ST FLOOR PLATE I1
93' - 1 5/8"
1ST FLOOR
85' - 0 5/8"
BASEMENT PLATE
84' - 0"
Average Grade
81' - 11 5/8"
Max. Hei ht
106' - 11 5/8"
Top of Ridge n
106' - 1 1 /8"
� _ 2ND FL00_R PLATE
102' - 3 1 /4"
E70
29
oO� -
a - ,
3„i12° 00
00
- o
CV
OD
_�,, 2ND FLOOR
13 0 94' - 2 1 /4"
1ST FLOOR PLATE
0 93' - 1 5/8"
O
o -
O
nnnn O oo E7
' ' ' '��������� o 0 1ST FLOOR
00 0� 85' - 0 5/8"
— I _ I
- FINISHED GRADE (APPROX) E84 III }-} I� � — -- -- — � � t BASEMENT PLATE
L�--t�—��� �I I�� �I — lL� I� 84 -0
EXI STI NGIGRADEi }-� {- � � _ � _ -- -f - � — t � � �4vera e Grade
- �_��-I---t�—�T � � I I I � �-81'-11 5/8��
—I-Ft—�it1—��T �� � I I I��
III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III I
WEST ELEVATION
V
z
N
W
Z a E
a ��
� Y x Q,
ula�u,
w ,� a�
���
O "�
U J�
���
M Cfl �
Z � N C
W � ��
� o °'
W op
J �
W a
H
O
U
C
�` %%_ _ +
c=== 'a
\`�� C
..r ` �
.`� II �
.. —
�� ��, ! �
�i�l � � >k...-.
Z �����° �m=���oo
}�� (/7 N N 3 J" N E T d N N C D
N Z_ `o � c m 0 d" a m c� m c c m n
Nam c:� � o L F `o p T � L U£� y E
2�¢ n a�� w c c m � .. o�� o U
O J N OIQCQ O O- N N O D= � N
U LL Q N�"� N C N w L ` l0 �Up�pJJ � E p Np
a W O � E O N N O n O d�� C N N O U
� W� U�� w c U c o c c= 3 c a� N
UJJH c m � $.oV aa'� m0 m� o
= O m��� v E w e a`� r c c L
r za_v @ �d o�Em�
RESUB
W
May 17 2023
V
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
W
�
N
h
�
W
pC
�
H
�
�
O
O
J
J
J
J
o
a
W
W
a
LL
LL
�
H
H
Z
O
_
_
�
W
�
Z
�
Z
W
�
0
a_
�
ZO
O
w
O
�a
Z O N
O
_
O Q
n
ii
V
V
�
�
�
M
(V
�
�
M
N
�
�
c
N
O
�
c
�
o
��
�
-a
N
-�
.goo
�
E
�
�
rn
L
o
�
��
��
�
�
Z
�
N
PROJECT NO.
210905
DESIGNED BY
TL
DRAWN BY
TL 8� RM
CHECKED BY
TL
SHEET NO.
PRINT DATE 5/12/2023 2:33:46 PM
Step 1: Prepare the WRB at the rough
opening: install a small section of house
wrap below the sill (referred to as an
"apron");alternatively, install self-adhesive
pan flashing with split backing (where the
release paper backing can be removed incre-
mentally) to seal to the house wrap later.
Step 2: Install pan flashing: cover the rough
sill and extend onto the face of the wall/
WRB.
Step 3: Install the window: according to
manufacturer instructions.
Step 4: Install the jamb flashing: over
window flange and pan flashing and extend
above the head flange.
Step 5: Install the head flashing: over and
beyond the jamb flashing (and over the win-
dowdrip cap if installed).
Step 6: Integrate the WRB: Install house
wrap shingle -fashion, integrated with the
apron, and seal house wrap at jambs and
head using sealant (beneath the house wrap)
or construction tape. SILL FLASHING NOTE:
INSTALL BENJAMIN OBDYKE
HYDROCORNER SILL FLASHING OR EQUIV.
ALL WINDOW SILL CORNERS
INSTALL BENJAMIN OBDYKE HYDROFLASH®GP SILL /
PENETRATION FLASHING OR EOUIV. OVER CORNER SHIELD, AS
EXTRA PREVENTION FOR LEAKS @SILL CORNERS
HEAD FLASHING NOTE: SEE NOTE BELOW -
DRAWING FOR INSTALLATION �O5 O
OF METAL HEAD FLASHING
@ THIS AREA
---
WEATHER RESISTIVE BARRIER
HYDROGAP DRAINABLE HOUSEWRAP
(BENJAMIN OBDYKE) W/BENJAMIN
OBDYKE HYDROFLASH®GP SILL /
PENETRATION FLASHING AND BENJAMIN
OBDYKE HYDROCORNER SILL FLASHING
(APPROVED SUBSTITUTIONS OKAY)
Housewrap
Rigid cap flashing
Flashing tape
over head trim
i
�o° to is°
slope � )
HEAD FLASHING NOTE: -
Flashing
AT WINDOW HEAD METAL DRIP
tape
FLASHING :INSTALL METAL HEAD
overtop
FLASHING @WINDOWS &EXTERIOR
flange
DOORS PER THE DETAIL BELOW.
Head trim �
Flashing tape
over side -
window flange
/I
�/4-in. gap
beneath
siding
WINDOW FLASHING
ELEVATION KEYNOTES
KEYNOTE N0. DESCRIPTION
E3
40+YEAR PRESIDENTIAL RANDOM CUT ARCHITECTURAL COMPOSITION ROOFING (IF PITCH
IS 3:12 OR LESS, INSTALL ROOFING OVER ICE AND WATER SHEILD.)
CONTINUOUS ALUMINUM GUTTER ON 5/4x6 FASCIA
E5
E9
FASCIA: 1x4 ON 5/4x10 (TYPICAL AT GABLE ENDS)
E14
HORIZONTAL BEVEL CEMENT BOARD SIDING PER BUILDER SPECS
E25
SLIMLINE METAL CORNER TRIM.
E44
TIMBER BEAM PER STRUCTURAL PLANS. STAIN OR PAINT PER OWNER SPECS.
E63
6"MINIMUM CLEARANCE ABOVE FINISHED GRADE OR PROVIDE TREATED MATERIAL PER
IRC317.
E66
CONCRETE LANDING AND STEPS PER IRC.
E70
HARDI PANEL SHEET SIDING WITH E-Z TRIM CHANNELS
E71
STONE VENEER PER MANUF. INSTALLATION SPECIFICATIONS o/P.T. PLYWOOD BOX FRAME
AND FRAMING o/ P.T. POST PER PLANS.
E81
EXTERIOR ENTRY DOOR w/TEMP. GLASS PER OWNER SPECIFICATIONS.
E83
DOUBLE SLIDING GLASS PATIO DOOR w/ TEMP. GLASS
E84
INSULATED STEEL OVERHEAD GARAGE DOOR
E85
GARAGE DOOR -ALUMINUM OR STEEL FRAMNE w/FROSTED TEMP. GLASS PANELS. MAKE
AND MODEL PER OWNER OR BUILDER.
E87
LOCKING DEADBOLD AT ENTRY DOOR.
E89
DOUBLE STORE DOOR w/ TEMP. GLASS.
Max. Height
106' - 11 5/8"
� Top of Rldge
106' - 1 1 /8"
0
— N
� Top of Ridge
2ND FLOOR PLATE �
102' - 3 1 /4"
2ND FLOOR
94' - 2 1 /4" ��
1ST FLOOR PLATE n
93' - 1 5/8"
— 1ST FLOOR �
85' - 0 5/8" V
��
�� rt � �r � � �fi - �� fi �� rt � �r � � �fi - �� fi �� rt � �r � � �fi � - �� fi �� � � �r � � �t � - �� � fi �� � �� � � -BASEMENT F 5009
NORTH ELEVATION
— -- SOLAR PANELS PER PLAN.
��— — �
o
E3
E5
_ _ _ _ _ _ 2ND FLOOR PLAT
102' - 3 1 /4"
E70
E9
28
i7p
0
_ — — — — — — _ — — _ — — 2ND FLOOR �
� — — — — — — — -- — — — — — — 94'-21/4"
1ST FLOOR PLATE tom,
93' - 1 5/8" �1
16
E14
17
Average Grade — � � � � � � � � � � � Es3
81 -11 5/8 — — _
III III — _
1--m - �--r r � fi �--r-r fi r-m - t�--r r � � �-r fi r-m - t�--r r � fi �-r fi r-m - t�--r r � t� r�-r fi r-m - t�--r r � � �--r-r fi r-rr - �--r
��� ��� ��� �� III III �� ��� ��� ��� ��� ��� III III � ��� ��� ��� ��� III III � ��� ��� ��� ��� ��� � III III �� ��� ��� ��� ��� ��� III III
EAST ELEVATION
_ 1ST FLOOR �
85' - 0 5/8" 1
BASEMENT PL E �.
84' - 0" �I
i+�
co
_ BASEMENT FLOOR
75� __9��
V
Z
N
W
o
Z ¢ E
a ��
� Y x Q,
ul o_ �u,
w ,n a�
���
O "�
U J�
���
M Cfl �
Z � N C
W � ��
� o °'
W op
J �
W a
H
O
u
C
�` %%_ +
c=== 'a
\`�� C
..r ` �
:: �i �
1 ' � �� �r�i� � ��'�
�� �I , � � �
I,' 1 h' t'�;; ''' �`�_�;:;
Z N .0..0 L i d � N C C U C O O
r� O N O J L N G O_ �� N O
N Z� � U C N Q d =' � (D U N C C N n
Nam C.0 � O L F O O T j L U E O N C
2�¢na=mow �ccm�.-���°
O J N OIQCQ O O- N N O D= � N
U LL Q N�"� N C N w L ` l0 �Up�pJJ � E p Np
a W O � E O N N O n O d�� C N N O U
p W� V o�� c U o p c c_ 3� a� N
UJJH c m � $.oU aa'� m0 m� o
= O m��� v E w e a`� r� c L
r za_v @ �d o�Em�
RESUB
W
May 17 2023
V
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
W
N
W
pC
�
H
O
O
N
ee�
�
eeJ
�
O•
W
W
a
LL
LL
�
�
�
z
W
�
Z
�
Z
W
�
0
a
�
z0
O
w0
�a
ZO "'�
o
� 11 �
o Q
�
V
�
�
�
M
(V
�
�
M
N
�
v
c
a�
o
.�
_�
o-a�
'�
.�
a�
o
0
�
E
�
L
o
�
m
a�i
�
�
.�
.�
�
�
Z
�
N
PROJECT NO.
210905
DESIGNED BY
TL
DRAWN BY
TL 8� RM
CHECKED BY
TL
SHEET NO.
PRINT DATE 5/12/2023 2:34:07 PM
DOOR SCHEDULE -BASEMENT FLOOR
SYM. N0. WIDTH HEIGHT � DOOR TYPE COMMENTS
BASEMENT FLOOR
D1 3' - 0" 6' - 8" SINGLE PANEL
KEYNOTE
N0.
KEYNOTE SCREED
DESCRIPTION
A01
GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE OR 20 MIN. FIRE RATED RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A
SELF -CLOSING DEVICE. (R302.5.1)
A02
LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN
THE TOP OF THE THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12.
(R311.3.1 & 311.3.2)
A03
GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR
EQUIV. IS REQUIRED BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 &TABLE 302.6)
A04
COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS.
RANGE HOOD SHALL HAVE LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM
SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT EQUIV. TO THE EXHAUST RATE. (M1503)
A05
CRAWLSPACE OPENING: MIN. 18"x24" THROUGH THE FLOOR OR MIN. 16"x24" THROUGH THE PERIMETER WALL. (R408.4)
A06
GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30"
ABOVE THE FLOOR OR GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO
THAT A 4" SPHERE CANNOT PASS THROUGH. (R312)
A07
STAIR TREADS AND RISERS (R311.7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE
ADJACENT TREADS. DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN. TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH
SHALL NOT BE GREATER THAN 3/8". FIREBLOCK STAIRS PER IRC 302.11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM
OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM (311.7.6)
A08
EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44"
ABOVE FLOOR. OPENABLE AREA IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE.
(R310.1)
A09
DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SHALL BE INSTALLED PER MANUFACTURER SPECIFICATIONS AND IN STRICT ACCORDANCE W/ LOCAL
BUILDING CODES. MUST BE U.L. LISTED. (M1303/ G2427.2.1)
A10
DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL.
MAX. DUCT LENGTH PER TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502)
A11
TYPICAL EXTERIOR WALL: SIDING o/INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT
INSULATION AND 1/2" MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER.
Al2
PILOTS, BURNERS, &SWITCHES TO BE 18" MIN. ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE
WALLS OR CEILINGS SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE.
WATER HEATERS SHALL BE ANCHORED AGAINST MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDE PRESSURE RELIEF LINE
PLUMBED TO OUTSIDE.
A17
CLOSET ROD w/VINYL COATED WIRE SHELF
A19
TEMP. GLASS DOOR
A20
TEMP. GLASS WINDOW
A24
FIBERGLASS TUB w/TILE SURROUND AND CURTAIN OR TEMP. GLASS DOOR PER BUILDER SPECIFCATIONS.
A27
UNDER -STAIR PROTECTION -ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER -STAIR SURFACES AND ANY SOFFITS
PROTECTED ON THE ENCLOSED SIDE WITH 1/2" GWB. (IRC R302.7)
A34
HEAT SENSOR AT GARAGE. INTERCONNECTED TO SMOKE DETECTORS PER R314.2.3.
2
1
BASEMENT FLOOR
co
N
O
M
N
CV
1
V
z
N
W
O
W
Z a E
a ��
� Y = Q,
ula�u,
w ,� a�
���
O "�
U J�
���
M Cfl �
Z � N C
W � ��
� O °�
W op
J �
W a
0
u
c
�` %%_ _ +
c=== 'a
\`�� C
..r ` �
.`� II �
.. —
�� ��� ! �
�' 1 I� � ��� " ��;�;.;
Z N .0..0 L i d � N C C U C O O
r� O N O J L N G O_ �� N O
N Z� �p U� .y � N y L N U N C C N .n
Nam c:� � _o t~ `o p T � L U E� y E
2�¢ n a�� w c c m �~���
O J N 0I QCQ O O— N t0 O D= � N
C� U LL� N�"� N C N w L '= l0 U� E N
aw�aEdNyoa�a��c�N�°�
p W� V o�� c U o p c c_ 3� a� N
UJJH c m � $.oU aa'� m0 m� o
= O m��� v E w e a`� r� c L
r z a_ v @ � d o� E m�
RESUB
W
May 17 2023
V
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
W
�
N
h
�
W
pC
�
H
t/�
t/i
O
O
O�
W
W
a
LL
LL
�
�
�
z
H
H
O
_
_
�
W
�
Z
�
Z
W
�
0
a
�
z0
O
wp
z0 N°
�a
o
�
o V Q
�
�
�
�
M
(V
�
�
M
N
�
�
C
N
O
�
C
�
���
��
�
N
.;oo
!_
�
�
;�
L
0
C
.>
.,
N�
L.1�
��/
I'✓
Z
�
N
PROJECT NO.
210905
DESIGNED BY
TL
DRAWN BY
TL 8� RM
CHECKED BY
TL
SHEET NO.
PRINT DATE 5/12/2023 2:34:24 PM
DOOR SCHEDULE - 1ST FLOOR
SYM. N0. WIDTH HEIGHT � DOOR TYPE COMMENTS
1ST FLOOR
D6
16' - 0"
8' - 0"
DOUBLE SLIDING PATIO DOOR
D7
18' - 0"
7' - 0"
OVERHEAD GARAGE DOOR
TEMP. GLASS PANELS IN METAL FRAME PER MFGR.
D8
3' - 6"
7' - 0"
SINGLE ENTRY -CONTEMPORARY (TEMP.)
TEMP. GLASS (U=0.28)
D9
2' - 8"
6' - 8"
SINGLE PANEL
D10
2' - 6"
6' - 8"
SINGLE POCKET
POCKET DOOR
D11
2' - 8"
6' - 8"
SINGLE PANEL
D12
3' - 0"
8' - 0"
SINGLE PANEL
D13
3' - 0"
8' - 0"
SINGLE PANEL
1 3/8" SOLID CORE w/SELF CLOSING MECHANISM. SEE KEYNOTE 1
D16
2' - 8"
6' - 8"
SINGLE PANEL
D17
3' - 0"
6' - 8"
SINGLE POCKET
POCKET DOOR
D18
3' - 6"
7' - 0"
Door -Opening
D19
6' - 0"
7' - 0"
OVERHEAD GARAGE DOOR -EMBOSSED
PANEL
INSULATED STEEL DOOR PER MFGR.
D20
6' - 0"
7' - 0"
DOUBLE GLASS (TEMP.)
WINDOW SCHEDULE - 1ST FLOOR
SYM. N0. WIDTH HEIGHT AREA WINDOW TYPE U-VALUE COMMENTS
1ST FLOOR
3
4' - 0"
5' - 0"
20 SF
PICTURE (FIXED)
0.28
4
4' - 0"
5' - 0"
20 SF
PICTURE (FIXED)
0.28
5
4' - 0"
5' - 0"
20 SF
CASEMENT -SINGLE
0.28
6
4' - 0"
4' - 0"
16 SF
SLIDER
0.28
8
4' - 0"
4' - 0"
16 SF
PICTURE (FIXED)
0.28
10
3' - 0"
5' - 0"
15 SF
PICTURE (FIXED)
0.28
11
3' - 0"
5' - 0"
15 SF
CASEMENT -SINGLE
0.28
12
3' - 0"
5' - 0"
15 SF
CASEMENT -SINGLE
0.28
13
4' - 0"
3' - 0"
12 SF
PICTURE (FIXED)
0.28
14
4' - 0"
3' - 0"
12 SF
PICTURE (FIXED)
0.28
15
4' - 0"
3' - 0"
12 SF
PICTURE (FIXED)
0.28
16
4' - 0"
4' - 0"
16 SF
SLIDER
0.28
17
5' - 0"
5' - 0"
25 SF
SLIDER
0.28
TEMP. GLASS
18
3' - 8"
2' - 0"
7 SF
PICTURE (FIXED)
0.28
19
4' - 0"
1' - 3"
5 SF
PICTURE (FIXED)
0.28
20
6' - 0"
1' - 3"
8 SF
PICTURE (FIXED)
0.28
22
4' - 0"
4' - 0"
16 SF
PICTURE (FIXED)
0.28
23
4' - 0"
1' - 3"
5 SF
PICTURE (FIXED)
0.28
1ST FLOOR PLATE
24
3' - 8"
2' - 0"
7 SF
PICTURE (FIXED)
0.28
25
3' - 8"
2' - 0"
7 SF
PICTURE (FIXED)
0.28
26
3' - 8"
2' - 0"
7 SF
PICTURE (FIXED)
0.28
Grand total 277 SF
KEYNOTE
N0.
KEYNOTE SCH ELDU LE
DESCRIPTION
A01
GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE OR 20 MIN. FIRE RATED RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A
SELF -CLOSING DEVICE. (R302.5.1)
A02
LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN
THE TOP OF THE THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12.
(R311.3.1 & 311.3.2)
GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR
A03
EQUIV. IS REQUIRED BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 &TABLE 302.6)
A04
COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS.
RANGE HOOD SHALL HAVE LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM
SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT EQUIV. TO THE EXHAUST RATE. (M1503)
A05
CRAWLSPACE OPENING: MIN. 18"x24" THROUGH THE FLOOR OR MIN. 16"x24" THROUGH THE PERIMETER WALL. (R408.4)
A06
GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30"
ABOVE THE FLOOR OR GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO
THAT A 4" SPHERE CANNOT PASS THROUGH. (R312)
A07
STAIR TREADS AND RISERS (R311.7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE
ADJACENT TREADS. DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN. TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH
SHALL NOT BE GREATER THAN 3/8". FIREBLOCK STAIRS PER IRC 302.11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM
OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM (311.7.6)
EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44"
A08
ABOVE FLOOR. OPENABLE AREA IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE.
(R310.1)
A09
DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SHALL BE INSTALLED PER MANUFACTURER SPECIFICATIONS AND IN STRICT ACCORDANCE W/ LOCAL
BUILDING CODES. MUST BE U.L. LISTED. (M1303/ G2427.2.1)
A10
DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL.
MAX. DUCT LENGTH PER TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502)
A11
TYPICAL EXTERIOR WALL: SIDING o/INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT
INSULATION AND 1/2" MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER.
Al2
PILOTS, BURNERS, &SWITCHES TO BE 18" MIN. ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE
WALLS OR CEILINGS SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE.
WATER HEATERS SHALL BE ANCHORED AGAINST MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDE PRESSURE RELIEF LINE
PLUMBED TO OUTSIDE.
A17
CLOSET ROD w/VINYL COATED WIRE SHELF
A19
TEMP. GLASS DOOR
A20
TEMP. GLASS WINDOW
A24
FIBERGLASS TUB w/TILE SURROUND AND CURTAIN OR TEMP. GLASS DOOR PER BUILDER SPECIFCATIONS.
A27
UNDER -STAIR PROTECTION -ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER -STAIR SURFACES AND ANY SOFFITS
PROTECTED ON THE ENCLOSED SIDE WITH 1/2" GWB. (IRC R302.7)
A34
HEAT SENSOR AT GARAGE. INTERCONNECTED TO SMOKE DETECTORS PER R314.2.3.
'v
M
v
M
'v
c�
rn
0
0
(V
CV
'v '
0
CV
ti
O
-v
0
CV
A B C D E F
45' - 6"
I I I I I / sue, I
5���'
ti'
16
�AN OPENIN OF NOT LESS THAN 100" SHALL I
i BE PROVED IN THE LAUNDRY CLOSET
ENCLOSURE OR MAKEUP AIR SHALL BE �
I I I I I PROVIDEDI BY OTHER APPROVED MEANS '
O�6,
�,
0 1
���
ti`� I -' � %� � � I A9 I
`� D.W. �
>� �
��
�'
'� KITCHEN \
' �� I
3.
�' ����
' A04 � RE
`� � � �
�' �'� �
� � � o
� � \� O
o
� n
-r, BUILT IN o �o, ��\ �w�/ 6 � „
��. " SETTE o � �� 13 - 9
d
-: � °�
-, 19 � 3 ��\� D17 1 \\ WASH'R AO
10 " -"._ $ O 80CFM � PRIMARY SUITE
I I
"- I ." I \ �� � 0
- - �o �r.o. DRY'R o0
`� � '� � LA U N D RY A10
io
�, �'� �� 2x6 W LL
- .. �,
1 � '�, � � I
A _� = _- A19 � `� 2�, QUEEN BED
- � , 2p" � �
� � ��A� � �� DOUBLE L -
�A02 ". - - � � s BARN -STYLE
D12
. - ,, - "_ ' / -8 DOOR DOOR PER NER
��
.0 4' OW
- �" � � �. ' �o � - . _ "_ A07 � ® o
,. "' O
9 UP C.°. _ BATH
-,,�" "" � � A20
- - - - � - -' - r _ 00
- `� A06
PATIO -
$oO
f)IRF(�T VFNT ,AS - - - - - - �I I _ I I v.r.o.
-" , � " " � "
6
O
�. �A$ , "� � �" ,� .� "; �,�
__- ---::- ---�. I
-„ - - - - �
�. - - -.. ."- 18'-0"�
9'-6"
1ST FLOOR
/ 1
5��� 23
22
I //,
A03
D19 LAW GARAGE
A34
HEAT SENSOR O
A03 2x6 WALL -
OFF CE
I � I ��
3 - �
13 �" A08
11'-1"
- �
14 4
-�-�-
15 5
' - 51 /2" 4' - 3" I
3'-6" 12'-
- � I�� .........
O � �O �� ��i�i�i�i�i�i�i�i
i�i�i�i�i�i�i�i�i
��i�i�i�i�i�i�i0
- �i�i�i�i�i�i�iO.'�
e � `�=
�.,
-
-
���
I I
4'-9" 2'-0" 3'-91/2" i II
I I
O I II I
I - I 6, _ 5„ I
-v I b
I , I
,„
- -� - -
I II
CV
A03 A01 A34
PWD � 140 CFM (MIN.) WHOLE A03
HOUSE EXHAUST FAN HEAT SENSOR
w/ TIMER
9'-11" 12'-2"
00
°�°�S�°� ENTRY � C GARAGE
SLOPE GARAGE SLAB
O 1/8" PER 1'-0" TOWARDS
9 DOOR.
. I
GARAGE CEILING: __
A03 5/8" TYPE "X" GWB UNDER
HABITABLE SPACES ABOVE.
0
A19
------ - - ---- - ----
I I I
I I
- - - �-
I � I
I R.O. FOR FUTURE I
o EQ EQ I ELECT. VEHICLE I
- � CHARGING STATION
� 22 1
02 ' � I I
� - - -- �
I I
I I
T-0" � � 23'-0"
5'-41/2" 7'-2"
2x6 WALL
D16
N
rn
M
FREE STANDING
SOAKING TUB
- -TEMP. GL. °O
WINDOW
1
A8
SHOWER
OPTIONAL SOAP
SHELF
A11
SEE BSMT. PLAN
CV
V
z
N
W
O
Z
a E
a
��
�
Y= m
ula�u,
w ,� a�
��
"�
O
J�
U
���
M Cfl �
Z
� N C
W
� ��
�
o
W
op
J
�
a
=
H
_ .,� °u
�, �,� +
//��=-
c=== 'a
\`�� C
Kr �
.`� II _ _ �
■a
�i � i ! I � � �� ���� I '�,' .
�� ��� ! �
�I�I � � >k...-.
i
Z N .0..0 L i d � N C C U C O O
r� O N O J L N G O- M O N O
N Z� � V C N � d" L N U N C C N n
Nam C .0 'w0- O L F O O T j L U E O N C
O J N OIQCQ O O- N N O D= � N
U LL Q N�"� N C N w L ` l0 �Up�pJJ � E p Np
a W O � E O N N O n O d�� C N N O U
p W� V o�� c U o p c c_ 3� a, N
UJJH c m � $.oU aa'� m0 m� o
= O m��� v E w� m t� c
r za_v @ �d o�Em�
RESUB
W
May 17 2023
V
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
W
N
W
�
H
t/�
t/�
O
O
J
J
J
J
o
a
W
W
a
Z
i
i
W
�
Z
�
Z
W
�
0
a
�
z0
O
=_
w
O
�a
Z O N
O
p Q
n
�
V
V
�
�
�
M
(V
�
�
M
N
�
v
c
a�
�
o
�
�.
c
�
o-a�
.�
�
�
.�
N
O
O
�
E
�
�
�
L
o
�
m
a�i
�
�
��
Z
�
N
PROJECT NO.
210905
DESIGNED BY
TL
DRAWN BY
TL 8� RM
CHECKED BY
TL
SHEET NO.
PRINT DATE 5/12/2023 7:48:12 AM
DOOR SCHEDULE - 2ND FLOOR
SYM. N0.
WIDTH
HEIGHT DOOR TYPE COMMENTS
2ND FLOOR
D21
2' - 8"
6' - 8"
SINGLE PANEL
D22
2' - 8"
6' - 8"
SINGLE PANEL
D23
2' - 6"
6' - 8"
SINGLE PANEL
D24
2' - 6"
6' - 8"
SINGLE PANEL
D25
2' - 8"
6' - 8"
SINGLE PANEL
WINDOW SCHEDULE - 2ND FLOOR
SYM. N0.
WIDTH
HEIGHT
AREA
WINDOW TYPE
U-VALUE
COMMENTS
2ND FLOOR
27
7' - 0"
4' - 0"
28 SF
CASEMENT -PICTURE
0.28
28
7' - 0"
4' - 0"
28 SF
CASEMENT -PICTURE
0.28
29
7' - 0"
4' - 0"
28 SF
CASEMENT -PICTURE
0.28
30
2' - 0"
3' - 0"
6 SF
SINGLE HUNG
0.28
TEMP. GLASS
Grand total 90 SF
KEYNOTE SCH ELD
KEYNOTE
N0.
DESCRIPTION
A01
GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE OR 20 MIN. FIRE RATED RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A
SELF -CLOSING DEVICE. (R302.5.1)
A02
LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN
THE TOP OF THE THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12.
(R311.3.1 & 311.3.2)
A03
GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR
EQUIV. IS REQUIRED BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 &TABLE 302.6)
A04
COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS.
RANGE HOOD SHALL HAVE LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM
SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT EQUIV. TO THE EXHAUST RATE. (M1503)
A05
CRAWLSPACE OPENING: MIN. 18"x24" THROUGH THE FLOOR OR MIN. 16"x24" THROUGH THE PERIMETER WALL. (R408.4)
A06
GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30"
ABOVE THE FLOOR OR GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO
THAT A 4" SPHERE CANNOT PASS THROUGH. (R312)
A07
STAIR TREADS AND RISERS (R311.7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE
ADJACENT TREADS. DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN. TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH
SHALL NOT BE GREATER THAN 3/8". FIREBLOCK STAIRS PER IRC 302.11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM
OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM (311.7.6)
A08
EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44"
ABOVE FLOOR. OPENABLE AREA IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE.
(R310.1)
A09
DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SHALL BE INSTALLED PER MANUFACTURER SPECIFICATIONS AND IN STRICT ACCORDANCE W/ LOCAL
BUILDING CODES. MUST BE U.L. LISTED. (M1303/ G2427.2.1)
A10
DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL.
MAX. DUCT LENGTH PER TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502)
A11
TYPICAL EXTERIOR WALL: SIDING o/INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT
INSULATION AND 1/2" MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER.
Al2
PILOTS, BURNERS, &SWITCHES TO BE 18" MIN. ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE
WALLS OR CEILINGS SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE.
WATER HEATERS SHALL BE ANCHORED AGAINST MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDE PRESSURE RELIEF LINE
PLUMBED TO OUTSIDE.
A17
CLOSET ROD w/VINYL COATED WIRE SHELF
A19
TEMP. GLASS DOOR
A20
TEMP. GLASS WINDOW
A24
FIBERGLASS TUB w/TILE SURROUND AND CURTAIN OR TEMP. GLASS DOOR PER BUILDER SPECIFCATIONS.
A27
UNDER -STAIR PROTECTION -ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER -STAIR SURFACES AND ANY SOFFITS
PROTECTED ON THE ENCLOSED SIDE WITH 1/2" GWB. (IRC R302.7)
A34
HEAT SENSOR AT GARAGE. INTERCONNECTED TO SMOKE DETECTORS PER R314.2.3.
HANDRAIL, GUARD AND
BALUSTERS TO CONFORM TO
I.R.C. OPENINGS SPACED
SUCH TF'"T " "" """r"r
CANNOTI
O
�
II
0
w
�
�
i
�
CO
CV
`i
i4S
_
�
�
z
� w
10"MIN.
�
-
� �
r,
TREAD
o
ti
iv
��
II
II
II
I
I I
II II
I II
RESIDENTIAL STAIRS TO BE
MIN. 36" (CLR) WIDE.
1/4" DIA. MIN; 2" DIA. MAX.
IANDRAIL w/ RETURNS TO
VALL.
TRIANGLE OF STEPS TO RAIL
OPENING SPACED SUCH THAT A
6" SPHERE CANNOT PASS THRU.
-FIRE BLOCK BETWEEN STUD
3/4"MIN; BAYS AT WALLS IN CONTACT
1 1/4" MAX. WITH STRINGERS.
NOSING 1/2"MIN. PLYWOOD
RISERS
TYPICAL STAIR DETAIL
DBL. JOIST
(U.N.O.IN PLAN)
SIMPSON
LUS210 JOIST
HANGER
- SIMPSON A35
EACH SIDE OF
STRINGERS
- (1) LAYER
1/2" GWB
- 2x12 STRINGERS
PER PLAN
A B C D E F G
I I I I I / I I
//�\
I I I I /� I� �.� I 1
� I � A9
�� � \�
� / I �
I I I �� � I I � I I
i� / I
i � I �
I I ��/ I/ I I I \� I I
i� � I \�
� I \
i�// � I \�
I �� I/ I I I I �� I/
i� I
,, / � /ram ---
� I� I I I I I // I
I
� � I � /
��\ � / //
�O I� I I I I I � / I I
I /
\\ � � //
\ I I I I / I // I I
� I � / 36' - 0"
1 �
A9 � 17'-9" '-31/2" 3'-6"
\ it /
I I �� I � � I // I
� � I /
\\ / I //
2ND FLOOR
H
I
-----I—�
6'-33/4"
I
V
z
N
W
O
Z
¢ E
a
��
�
Y= m
ula�u,
w ,� a�
���
"�
O
J�
U
���
M Cfl �
Z
� N C
W
� ��
�
o °'
W
op
J
�
W
a
H
0
u
c
Hr W
.`� II �
.. —
�� ��� ! �
�i�l � � >k...-.
�' 1 h' ��� " ��;�;.;
Z �����,� �m=���oo
oz� o� o �OL"a m L ai `o a�i 16 n
cram c.�� _otF `ooT�LU E_�v,E
2�¢ n a�� w c c m � .. o�� o U
Ur � J U y N p Cp U� L N U D� t y`
� Q N �� C N .r L �` l0 U� E N
aw��EdNyoa�a��c�No°o
O W� U o �'U w� U o o c c= 3 c a� N
UJJH c m � $.oU aa'� m0 m� o
= Om���v Ew�a,t�c
r za_v @ �d o�Em�
RESUB
W
May 17 2023
V
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Z
W
N
W
pC
H
�
�
O
O
N
J
J
J
�
�
a
W
W
a
Z
W
�
Z
W
�
Z
�
0
a
�
z0
O
wQ
Z� N�
�a
o
�
o Q
�
V
�
�
���
M
(V
�
M
N
�
c
a�
o
�
.c
�
o
'w
�
-a
N
-�
.�
a�
o
0
�
E
�
�
;�
L
0
C
�
�
�
y
�
�
Z
�
N
PROJECT NO.
210905
DESIGNED BY
TL
DRAWN BY
TL 8� RM
CHECKED BY
TL
SHEET NO.
PRINT DATE 5/12/2023 7:48:28 AM
A
2ND FLOOR PLATE �
2ND FLOOR �
1ST FLOOR PLATE
1ST FLOOR
BASEMENT PLATE
I
�N D
>TION
AND
\TION
1 BUILDING SECTION
A8 s�A�E.�,,.a
V
z
N
W
Z
QU
>Q O
�
1' 2 rn
wa��,
��v
"��
O
J
J V �
U
���
M � w
Z
ANC
W
N
� ��
�
o °�'
W
m
J
O
a
W
H
R
V
,K ,%r
f
/�,�! + vi
"/ 4s�c:. N
,�
�
� i ���
C
"' II �
�
� i,
� V�
ALA''
W
n
�
CC •■
L��
.y
Z H O V .0 N r` O L�� a �� C 0
N} owcctidE�a� cm'-
�QZyc`-'��°aU ca���o°aa
2
.. .- c � m y 2
� U m L f0 N @ O y� L =� f0 USE N
aw�'�U c y c � a`�i� o d d a`-' o 0
UwO
nam`o mJOQ��O ?�o°
v w d � w t aEi �� o� E� m
��
J Q O �
RESUB
W May 17 2023
V CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
W
y
O O
�
� �
� �
O
�
W W
a
LL LL
�
o
�
T� T�
i i
�
w
� �
Z Z
W
�
� �
�
ZO O
a
w
w_ O z O N
o
�
Q
� � � � �
�
M
O Q
1�
a�
0
c
0
r
a
�L
i.i
0
0
z
PROJECT NO.
210905
DESIGNED BY
TL
DRAWN BY
TL & RM
CHECKED BY
TL
SHEET:
PRINT DATE 5/12/2023 7:49 AM
ROOFING PER ELEVATIONS
o/ 30# FELT OVER
SHEATHING PER STRUCTURAL
o/ MANUF. TRUSSES PER PLAN
FASCIA BOARD PER ELEVATIONS
R-49 BATT OR BLOWN INSUL.
THROUGHOUT ATTIC AREA
SOFFIT PER ELEVATIONS
BACKING
1ST FLOOR PLATE
FRAMING MEMBER ATTACHED TO
TOP PLATES PER STRUCTURAL
(2) 2x6 TOP PLATES.
STAGGER JOINTS A MIN. OF 48"O.C.
%" G.W.B. CEILING BOARD
EXTERIOR FINISH PER ELEVATION o/
15# BUILDING PAPER OR
APPROVED AIR INFILTRATION
BARRIER o/ SHEATHING PER
STRUCTURAL PLANS
R-21 BATT INSULATION
(IN FULL WALL CAVITY)
2x6 STUDS @16" O.C.
(U.N.O. IN STRUCTURAL)
%" G.W.B. w/APPROVED
P.V.A. VAPOR RETARDER
3/4" T&G PLY OR EQUIV. SUB -FLOOR
GLUED &NAILED TO
FLOOR JOISTS PER STRUCTURAL
R-21 BATT INSULATION AT RIM
CAULKING/ SEALANT BEAD
AT FLOOR PERIMETER
P.T. BASE PLATE PER
STRUCTURALPLAN�
1ST FLOOR -
BASEMENT PLATE
(1) LAYERS 8'
TYPE "X" GWE
4" CONC. SLAB.
o/ COMPACTED GRANULAR FILL
FOUNDATION WALL SIZE AND
REINFORCING PER
STRUCTURAL PLANS
THERMAL BRAKE
BASEMENT FLOOR _
4" PERF. FT'G DRAIN. WRAP IN FILTER
FABRIC w/GRAVEL OVER FABRIC
FOOTING SIZE AND REINFORCING
PER STRUCTURAL PLANS /
-�
a
e Q
e�
e
d
a a
25'-0"
RADIA T COIL HEATING IN 1.5"
LIGHT IGHT CONCRETE.
STORAGE / MECH. RM.
a - d a L - a ad
12
�3
KITCHEN
RADIANT COIL HEATING IN 1.5"
LIGHTWEIGHT CONCRETE.
a _ e � e a
1 BUILDING SECTION
A9/ SCALE: 1/2" = 1'-0"
J
Z
ROOFING PER ELEVATIONS
o/ 30# FELT OVER
SHEATHING PER STRUCTURAL
o/ MANUF. TRUSSES PER PLAN
R-49 BATT OR BLOWN INSUL.
THROUGHOUT ATTIC AREA
1"AIR SPACE w/
BAFFLE. EXTENDED
24" ABOVE INSULATION
VENT BLOCKS w/ (3) 2" dia. WIRE
SCREENED VENTHOLES
@ EA. BLOCK
RIM JOIST PER STRUCTURAL
R-30 BATT INSULATION
4" TIGHTLINE DRAIN WHERE REO'D
U
z
N
W
Z
>Q O
Q U
Y 2 0�
Wl a '�,
w��
� � a
"��
O
J V �
U ��o
z °�
N N ..
W � �@
pC o °�'
W m
� o
W
H
O
%R ,
t�
/,
�� +
.�
�
.�
'
� I
K � I I i
AC�
�I
�
� n
ALA,,
W
CC ���
—
Iii.IL,� � h
I. 1 s f'�..
n!.! .I
N
U W N N .w �= 'O N -O N O O O
c
Z U E �.N a L �� c� � w .-
o r� m a@ o
}~� O U C C U N E �' C O
�N Cp d
N Q O C U O. (, O �� �� N d
���aoa�o=ga��"�Noo
O -O O. N N O
J N C N �p "O NL- N i
O
_ � w
�Um�mfO �OON�L''=mU�EN
} W¢�� y y� U N O) � N y 0
OWW °w�o3a�i >.ti o�c3a:60o
UJO o u � =O m3 0 �—p..-�o N
W _ n n °� E d
� � -°o '� � o w m � �' a F �
J Q O �
RESUB
W May 17 2023
V CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
W
y
W
DC H
O O
� �
� �
O
a
W W
a
� �
�
�
T� T�
i i
�
W
� �
Z Z
H
W
�
� � �
a
z0 O
o
wQ Z� N�
� � � � �
� O ¢
M
n
a>
a
0
c
y.+
.`
N
a>
C
Z
PROJECT NO.
210905
DESIGNED BY
TL
DRAWN BY
TL & RM
CHECKED BY
TL
SHEET:
PRINT DATE 5/12/2023 7:51 AM
SEE 3/S1 FOR ALTERNATE AT WOOD FRAMING PER PLAN VARIES.
HUNG JOISTS SEE 20/S8 FOR CONNECTIONS AND
GENERAL NOTES WQQD
FRAMING NOT SHOWN
All design and construction shall conform to the requirements of the 2018 International Building SAWN LUMBER: Structural sawn lumber shall be kiln dried and be of the species and grade noted
PT SILL PLATE w/ANCHOR BOLTS
SHEAR WALL PER PLAN FLOOR BOUNDARY NAILING PER
Code. below or better:
SEE 11/S1 AND 12/S1 FOR AND WASHERS PER SHEAR WALL
DIAPHRAGM SCHEDULE
Use Grade Fb si
FOUNDATIONS GREATER SCHEDULE. MINIMUM ANCHOR
SHEAR WALL PER PLAN
Contractor shall verify all levels, dimensions and existing conditions in field before proceeding with Wall Studs Hem Fir Stud 675
THAN 4 FT BOLT EMBEDMENT = 7".
2x PT SILL PLATE RIPPED TO
SOLE PLATE NAIL/SCREW
MATCH CONC. WALL WIDTH w/
any construction or demolition. Contractor shall notify the Architect of any discrepancies or field Plates &Planks Hem Fir #2 850
BOLTS PER SHEAR WALL
changes Joists &Rafters Hem Fir #2 850
SHEAR WALL PER PLAN
PT SILL PLATE w/ANCHOR BOLTS
SCHEDULE
4x Beams Douglas Fir -Larch #2 900
Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or 6x Beams Douglas Fir -Larch #2 875
AND WASHERS PER SHEAR WALL
EDGE NAILING
procedures required to perform the work. Contractor shall provide adequate shoring and bracing of Posts Douglas Fir -Larch #2 750
SCHEDULE. MINIMUM ANCHOR
BOLT EMBEDMENT - 7".
all structural members, existing construction and soil excavations as required, in a manner suitable 2x4 T&G Decking Douglas Fir -Larch Select 1750
to the work sequence. Temporary shoring and bracing shall not be removed until all final
connections have been completed in accordance with the drawings and materials have achieved All lumber and plywood exposed to weather or water or in contact with concrete, stucco, masonry
�
design strength. Foundations walls greater than 4 feet shall not be backfilled until the floor framing or other cementitious materials shall be treated with an E.P.A. acceptable wood preservative, such
�
,�
and all connections to the floor framing per these details are complete. as Alkaline -Copper -Quaternary "ACQ" or Copper Azole "CBA" type A and B.
�\//�
�\\/�
8" THICK WALL ���\ #4 HORIZ. AT 18' o.c. AND (2) AT
8" THICK WALL ���\ #4 HORIZ. AT 18" o.c. AND (2) AT
CHANGES: No than es to these structural drawin s are ermitted without written consent of the All wood connectors shall be manufactured b Sim son Stron Tie Com an or a roved e ual
9 9 P Y P 9 P Y( PP q )�
UNLESS NOTED TOP OF WALL
UNLESS NOTED TOP OF WALL
SLAB ON GRADE FLOOR JOISTS PER PLAN,
PER PLAN
Engineer. Changes will be billed to the client, owner or contractor at the Engineer's hourly rate. and of the size and type shown on the drawings. All wood connectors in contact with
OTHERWISE
#4 VERY. DOWELS AT 24" o.c.
OTHERWISE
#4 VERY. DOWELS AT 24" o.c.
JOIST BLOCKING AT 48" o.c. WHERE
preservative -treated wood shall be Triple Zinc G-185 galvanized (1.85 oz/sq ft coating).
Q z ALTERNATE HOOK AT BASE
Q z ALTERNATE HOOK AT BASE
JOISTS ARE PARALLEL TO WALL.
SUBMITTALS: Shop drawings shall be submitted to the Architect prior to any fabrication or
� �
� �
construction for all the following: MINIMUM WOOD NAILING REQUIREMENTS: Unless otherwise noted on the drawings, typical wood
- -
_ -
HANGER PER PLAN
Structural steel, steel canopies, glued -laminated members and pre -manufactured wood framing shall be fastened as follows. See IBC Table 2304.10.1 for fastener alternatives not shown.
O0 00 PERF. FTG.
� � DRAIN � FOOTING PER PLAN
� °� PERF. FTG.
� `� DRAIN FOOTING PER PLAN
PROVIDE VAPOR BARRIER BETWEEN
� JOIST AND CONCRETE WALL
members. Location Min. Nail Quantity/Spacing Type*
Beams (built up 2x's) 3" x 0.131" 24" o.c. T&B* FN
FOUNDATION PER PLAN.
Design drawings and calculations, for pre -manufactured wood trusses and joists shall bear the seal EF* staggered
�
�
SEE DETAIL 1/S1 UNLESS
and signature of the Washington State Registered Professional Engineer who is responsible for the Blocking -to joists, rafters, trusses 3" x 0.131" 2 each end TN
_
M � �
_
M J
v -
NOTED OTHERWISE
.-
O
design, and shall be submitted to the Architect and Building official for review prior to fabrication. or studs
-to top plates 3" x 0.131" 3 TN
DESIGN LOADS Bottom plate -to joist, rim joist 3" x 0.131" 12" o.c. FN
LIVE LOADS: Live loads are determined in accordance with ASCE Ch. 4 or blocking
L = 40 PSF (Residential) -to studs 3" x 0.131" 3 EN
TYPICAL CONCRETE FOUNDATION
1
TYPICAL CONCRETE FOUNDATION AT SLAB
2
HUNG JOISTS AT TYPICAL STEM WALL
3
= 60 PSF (Balcony) Header (built up 2x s) 16d box 12 o.c. T&B FN
SNOW LOADS: Snow loads are determined in accordance with ASCE Ch. 7 with the following Header -to studs 3" x 0.131" 4 TN
Factors: Joist -to supports 3" x 0.131" 3 TN
Ground Snow Load Pg = 20 psf Ct = 1.0 Ce = 1.0 -to rim joist 3" x 0.131" 4 EN
Roof Snow Load Ps = 25 psf Is - 1.0 Rafter -to supports 3" x 0.131" 4 TN, EN
WIND LOADS: Wind loads are based on ASCE 7 Ch. 28 (Envelope Procedure) with the following Rim Joist -to sill or blocking 3" x 0.131" 6" o.c. TN
LAP JOIST OVER BEARING MIN. 6" FLOOR SHEATHING PER
factors: Stud -to Stud 3" x 0.131" 12" o.c. FN
� ��
24
AND NAIL WITH (3) 10d STRUCTURAL NOTES
Ex osure Cate o = B -to top/bottom plate 3" x 0.131" 4 TN
P g ry
PT SILL PLATE w/ %"� ANCHOR
�� �� ��
Veloci 3 sec = 100 m h ult Kzt = 1.0 Top plate -to top plate 3 x 0.131 12 o.c. FN
tY ( ) P ( )
#4 x 24"
BOLTS AT 48" o.c.
7" MIN EMBED
Design wind pressured for determining forces on components and cladding are determined in -to studs 3 x 0.131 3 EN
MATCH HORIZ
TYP. WALL
I
accordance with ASCE 7 Cha ter 30. -laps at corners and 3" x 0.131" 3 FN
P
REINF.
REINF. TYP.
I
- - - - - -
SEISMIC LOADS: Seismic loads are based on the Equivalent Lateral Force Procedure in ASCE 7-16 intersections
24
STUD WALL PER PLAN
Section 12.8 with the following factors: Truss to top plate 3 x 0.131 4 TN
Risk Category = II Ss = 1.28
#4 x 24"
Site Class = D S1 = 0.500 *EN =end nail, FN =face nail, TN =toe nail, EF = "each face", T&B = "top and bottom"
MATCH HORIZ
FLOOR JOISTS PER PLAN
Design Category = D SDS = 0.851
REINF.
INSULATION PER ARCHITECTURAL
RATED SHEATHING: Wood structural panels shall bear the APA trademark of the American Plywood
R = 6.5 (wood shear wall) SD1 = 0.600
2x CONY. BLOCKING
Ie = 1.0 Cs = 0.131 (ult.) Association. Sheathing shall be as follows:
OVER BEAM BEAM PER PLAN
Shear Wall Shtg APA rated 7/16" 32/16 C-D INT with Exterior Glue (CDX or OSB)
HORIZONTAL EARTH LOADS: Horizontal soil loads used for design of retaining walls and
` :
FLOOR JOISTS PER PLAN, JOIST
basement walls are based on assumed soil values typical of this region. Roof Shtg APA rated 15/32" 32/16 C-D INT with Exterior Glue (CDX or OSB)
POST PER PLAN WITH CAP
BLOCKING AT 48" o.c. WHERE
Active Pressure (Restrained) -55 pcf (EFP) Sub Floor Shtg APA rated 3/4" 48/24 T&G C-D INT with Exterior Glue
(OR GUSSET PLATE) AND
JOISTS ARE PARALLEL TO WALL
Active Pressure (Unrestrained) -35 pcf (EFP) Sheathing shall be orientated over the supports as shown on the drawings. Shear wall sheathing
ALT. HOOK
BASE PER POST SCHEDULE
Passive Pressure -250 pcf (EFP) shall be blocked at all panel edges as shown in the shear wall schedule.
SINGLE REINFORCING #4 x 24"
#30 FELT BETWEEN POST AND
CONCRETE WALL AND
Coefficient of friction -0.4
GLUED LAMINATED MEMBERS: Glued Laminated members shall each bear an AITC identification
MATCH HORIZ
VAPOR BARRIER PER CONCRETE (NOT REQUIRED AT
PRESSURE TREATED POSTS)
REINFORCING PER 1/S1 a Z
mark and be accompanied by an AITC certificate of conformance. One coat of end sealer shall be
REINF.
ARCHITECTURAL
g �
FOUNDATIONS applied immediately after trimming either shop or field. Members shall be Visual Graded Western
FOOTING WITH
FOOTING PER PLAN � �
The allowable soil bearing pressure used for design = 2000 psf based on assumed values typical of Species Inductrual, Architectural or Premium grade with strength as follows:
NOTES:
REINFORCING PER PLAN
this regioN. Plan Symbol Common Name S ecies Fb E
1. VERTICAL REINFORCING NOT
- �
GLULAM Glulam DF 24F-V4 DF/DF 2400/1850 psi 1,800,000 psi
SHOWN FOR CLARITY
M v FINISHED GRADE
Concrete foundations shall be placed on Bearing Ground defined as follows. Bearing Ground shall be GLULAM V8 Glulam DF 24F-V8 DF/DF 2400/2400 psi 1,800,000 psi
2. SEE STRUCTURAL NOTES FOR
stiff, competent, non -expansive, undisturbed native soil. Where native soil is inadequate for bearing,
CLEAR COVER DOUBLE REINFORCING
foundations shall be placed on structural fill mixed and compacted in accordance with specifications ENGINEERED COMPOSITE LUMBER: Engineered Composite Lumber shall be manufactured by
provided by a Washington State licensed Geotechnical Engineer. Trus-Joist, Boise Cascade or approved equal and shall have the following minimum strength (based
on 12" member depth):
Bottom of footing elevation shall be located at minimum frost depth 18" below top of finished grade Symbol Common Name Manufacturer Fb _E
TYPICAL CONCRETE WALL AND FOOTING CORNER
4
TYPICAL CRAWL SPACE FRAMING
5
SECTION
6
unless required otherwise by the Building Official. The contractor shall confirm the minimum frost PSL Parallam Trussjoist 2900 psi 2,000,000 psi
depth with the Building Official prior to excavation. LVL Micolam Trussjoist 2600 psi 2,000,000 psi
LSL Timberstrand Trussjoist 1700 psi 1,300,000 psi
CONCRETE VL (13/-2%") versa Lam Boise Cascade 2800 psi 2,000,000 psi
Concrete work shall comply, in general, with ACI 301 (latest edition) "Specifications for Structural VL (3%" &wider) Versa Lam Boise Cascade 3100 psi 2,000,000 psi
A35 EACH BLOCK BOTH SIDES
STAGGERED
Concrete for Buildings."
PREMANUFACTURED OPEN WEB WOOD TRUSSES: Trusses shall be design by a Structural Engineer
10d AT 4" o.c. TO BLOCKING
CONCRETE MIXES: Concrete mixes shall conform ACI 318 Ch. 5. Minimum concrete strength fc at licensed in the State of Washington, who is regularly engaged in the design of plate -connected
SHEAR WALL PER PLAN. SHEAR WALL PER PLAN.
28 days shall be as follows: wood trusses. Truss design shall be accordance with IBC Section 2303.4.
FLOOR JOISTS PER PLAN
SEE 20/S8 FOR SEE 20/S8 FOR
Slab -on -grade, Curbs and Pads - 2000 psi
Trusses shall be design for the following superimposed dead loads:
CONNTECTIONS. A35 EACH JOIST BOTH SIDES CONNTECTIONS. EXTEND BLOCKING
FLOOR BOUNDARY NAILING
Footings - 2500 psi
top chord bottom chord total
STAGGERED AND NAILING TO 3RD
A35 EACH JOIST BOTH SIDES
Walls, Stems - 3000 psi (2500 psi used for structural design)
BAY AT 32" o.c.
STAGGERED
roof trusses 10 psf 5 psf 15 psf
- - - - - - - - - - - - - -
CONY. SOLID BLOCKING
Water/cement ratio shall be measured by weight and shall be based on the total cementitious
CONY. 2x RIM JOIST
material. Water/cement ratio shall be determined by the supplier based on strength requirements In addition to dead loads, the design shall include the live, wind, snow loads as identified in the
CONY. 2x RIM JOIST
and shall not exceed 0.55. Water -reducing admixtures may be incorporated in concrete mix designs "Design Loads" section of these drawings, and the snow drift, sliding and unbalanced loads per
but shall conform to ASTM C 464, and be used in accordance with the manufacturer's ASCE7 Chapter 7. The truss design shall include concentrated and axial loads shown on framing
recommendations. CaCI and other water-soluable chloride admixtures shall not be used. plans and hanger schedules in these drawings.
SHEAR WALL SHEAR CLIPS SHEAR WALL SHEAR CLIPS
OR ALTERNATE PER 18/S8 OR ALTERNATE PER 18/S8
REINFORCING STEEL: All reinforcing shall be deformed bar (rebar) with bar diameters specified in Roof trusses shall be designed for wind net uplift of 10 psf unless otherwise noted on the drawings.
these drawings and properties below:
All reinforcing unless noted otherwise - ASTM A615, Grade 60 Trusses shall be fabricated by a manufacturer who is a member of the Truss Plate Institute. Trusses
#3 stirrups and ties - ASTM A615 Grade 40 shall be supplied with the proper hangers, end connections, bridging, bracing to provide lateral
• (1) BAYS OF 2x BLOCKING
� DOUBLE PRESSURE TREATED . AT 16" o.c.
Welded rebar - ASTM A706, Grade 60 stability of all truss members, and tie -down connections to beams and tops of walls. Trusses shall
2x8 SILL PLATE NAILED WITH
SHEAR WALL SHEAR CLIPS
Galvanized Welded Wire Fabric - ASTM A165 be supplied with tapered hardwood shimming so that every chord bears on the full width of every
(2) ROWS 10d AT 6" o.c. DOUBLE PRESSURE TREATED
DOUBLE PRESSURE TREATED
support, without notching the truss members. The truss manufacturer is responsible for ensuring
2x8 SILL PLATE NAILED WITH
2x8 SILL PLATE NAILED WITH
Reinforcing steel shall be detailed in accordance with ACI 315 "Manual of Standard Practice for the bearing seat does not exceed the sill plate capacity of the supporting element.
(2) ROWS 1od AT 6" o.c.
(2) ROWS 10d AT 6" o.c.
Detailing Reinforced Concrete Structures."
PREMANUFACTURED WOOD I -JOIST: Shall be fabricated by Truss -Joist or Boise Cascade.
s �� s ��
/s DIA. ANCHOR BOLTS AT / DIA. ANCHOR BOLTS AT
Reinforcing steel shall be lapped as noted on the drawings. Where lap length is not shown, Alternative manufactures must be approved by the Architect or Engineer. Joists shall be installed
16" o.c. UNLESS TIGHTER 16" o.c. UNLESS TIGHTER
reinforcing bars shall be lapped as follows: according to the manufactures instructions including blocking, web stiffeners, bridging, etc. Fasten
SPACING IS REQUIRED PER 1-1/2" CLR. SPACING IS REQUIRED PER
%" DIA. ANCHOR BOLTS AT
#5 and smaller - 48 bar diameters joists to supports as recommended by the joist and hanger manufacturer. Provide temporary
SHEAR WALL SCHED. FROM INSIDE FACE SHEAR WALL SCHED.
16" o.c. UNLESS TIGHTER
bracin as recommended b the manufacturer to hold oasts in lace until ermanentl secured, Cut
#6 and larger - 60 bar diameters g y � P P y
EMBED = 7" MIN (+1/4", -0") EMBED = 7" MIN
SPACING IS REQUIRED PER
openings in joist webs only as allowed by the manufacturer.
SHEAR WALL SCHED.
EMBED = 7" MIN
Minimum concrete cover over reinforcing shall be as follows:
Nonstructural Slab -on -grade - Mid -Depth RECOMMENDED INSPECTIONS
•
a
Wall Bars: interior face - 3/4" The following recommended minimum items shall be inspected by a qualified individual
8" THICK CONCRETE WALL REINF. a
� � CONCRETE WALL AND
WITH #5 VERY. AT 12" o.c. AND
exposed to earth/weather - 1-1/2" (#5 and smaller) designated by the Building Official:
o o REINFORCING PER "JOISTS
#4 HORIZ. AT 18" o.c. AND (2) AT
CONCRETE WALL AND
2" #6 and lar er �� ��
( 9 ) -Footings bear on competent native soil per the Foundations section above
� � PERPENDICULAR TO WALL"
TOP.
REINFORCING PER 11/S8
Footings: Bottom Bars - 3" (cast against earth) -Footing reinforcement
Top Bars - 1-1/2" -Shear wall sill plate anchors and washers per schedule
Side Bars - 2" -Shear wall nailing and shear clips per schedule
12" THICK LAYER OF � 12" THICK LAYER OF �
FREE -DRAINING GRAVEL FREE -DRAINING GRAVEL
-Shear wall hold-downs
Provide supports as required for proper alignment and concrete cover around the reinforcement.
FULL HEIGHT OF WALL FULL HEIGHT OF WALL
12" THICK LAYER OF �
FREE -DRAINING GRAVEL
Consult the CRSI Manual of Standard Practice MSP-1 for specific information.
FULL HEIGHT OF WALL
#4 DOWEL AT 18" o.c. CENTERED
� ALTERNATE HOOK AT BASE �
SLAB ON GRADE PER PLAN SLAB ON GRADE PER PLAN
-
SLAB ON GRADE PER PLAN
0
N
TYPICAL DETAILS
In addition to the details and schedules on the framing plans, those noted as "Typical" shall be
used throughout the structure as applicable.
SLAB ON GRADE PER PLAN
PERF. FTG. DRAIN IN PERF. FTG. DRAIN IN
12" GRAVEL 12" GRAVEL
� �
: � •
U U
M
JOISTS PERPENDICULAR TO WALL "' JOISTS PARALLEL TO WALL
J
U
M
STRUCTURAL NOTES
FULL HEIGHT CONCRETE BASEMENT WALLS -BRACED
1 1
SECTION
12
Ross
Engineering
Design
Inc
rya n. ross@ rosseng i neer.com
4.30.2023
yPNN.R�s
� pE WAS,yi,�, S
�z
�
J B#
2 02
46411 �
�� 'PfGISTER�� \��
SS�ONAL ��v
ELECTRONIC COPY
ORIGINAL ON FILE AT
ROSS ����Cj �IGN
�2023
�I ayC1J7
� CITY OF EDMONDS
LOPMENT SERVICES
ZDEPARTMENT
W
�
t~
H
W
� H
H
O O
�
J �
J �
W W
a
a
LL LL
O
TH T�
i Z
�
W
Z Z
W
�
� �
Q
Z � O
a
w O Z O
� O
� �
� Q
O�� 11�� � 1�
V O V
�
Q �
a�
0
c
0
Q.
N
m
G
Z
FILE/ NO.
20000
DESIGNED BY
RR
DRAWN BY
RR
CHECKED BY
RR
SHEET:
PRINT DATE 4 / 26 / 2023
ST .
c
it
II
i
>�
II
�I
________________� �__________________________________________ J{
�',',
EXTERIOR WALLS
NOT MARKED SHALL BE
SW1
HOLDDOWNS CALLED OUT
ARE LOCATED AT BASE OF
SHEAR WALLS.
SEE SHEET S8 FOR SHEAR
WALL SCHEDULE AND
HOLDDOWN SCHEDULE
2ND FLOOR SHEARWALLS
SCALE: 1 /8" = 1'-0"
EXTERIOR WALLS
NOT MARKED SHALL BE
SW1
HOLDDOWNS CALLED OUT
ARE LOCATED AT BASE OF
SHEAR WALLS.
SEE SHEET S8 FOR SHEAR
WALL SCHEDULE AND
HOLDDOWN SCHEDULE
1ST FLOOR SHEARWALLS
SCALE: 1/8" = 1'-0"
U
z
N
W
Z >Q o
Q > U
Y 2 0�
Wl a '�,
w��
� � a
O "��
J V �
U ��o
Z ���
N N '..
W � �@
pC o °�'
W m
� o
W
H
O
t�
C
-�- �
�N
C
AL,
W
N
Z U E� .N a L �� c m i� c w .-
o r� m a@ o
}~� O U C C U N E �' C O
NQO C U�N O. (, O�� � � Cp N dd
��� O. O Q� O C CO �` O" U -p N �
O O J N C N -O O. t6 O N O 'p NL-. N i
� Z Q .5.. .@. f0 y N O N O s '- l6 U C E C
d �' J O U O N C C� � O d N N. 6 O �
OUZO o'u � �O m- � m� 3 c °' `�
W H nnm-O d� O'am �� �'o �
�� -°o '� b o w s m� �' a F E n d
� Q o �
4.30.2023
y p,N N. RCS
Q�
pE W ASHiN S
�i
�
J B#
2 02
��
46411 �
'�FGISTERE� \��
SS�ONAL �-�G
ELECTRONIC COPY
ORIGINAL
ON FILE AT
ROSS ENGINC�9FjSl��
W May 17 2023
V CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
W
� N
H �
W
DC �
� �
O O
J J
J J
o
�
W W
a
LL LL
?�
H H
O
_ =
o
W
� �
Z Z
H
W
�
� � �
a
z0 O
o
wQ Z� N�
� � � � �
� O ¢
M
n
a�
a
0
c
0
.`
N
a>
C
Z
PROJECT NO.
210905
DESIGNED BY
TL
DRAWN BY
TL & RM
CHECKED BY
TL
SHEET:
PRINT DATE 4/29/2023 10:06 AM
A B C D E F G H
I, i i i i � -�'' i I,
I i i i i/ �- i I
I I I I / �\ I, I, I
'I, I I I / I \ ��, I I, I
I, I I I S1 I, I, I
I I I I I 4" FLOOR I
I I I I / I � \ 'I DRAIN I
'I, I I I / \ I/ I i I
I I I I / °°°'/� �o \I I I
I, I I I / / \ �o I \ I I
I I o f I / �/ � I, I �'' I
I, I I - / I I\ �� I �-� I
I I I/ �/ I I- \ I I �" I
/ �� �-
• •° BOILERS AND \ ' /
/ / H.W.T. a. �,
I / �° � I / \� ° \ I I �,
I, I / , . / I I � I O/ � \ I I �-�,
/ 4" FLOOR \ �-�
I / I °j � STORAGE -BOOM DRAIN / / � ��- H
/ 4" CO ETE SLAB ' / \ �
- - - - - - - - - - - - - - - - - - / �� I - -- - - - - I - - - �- - / - i - - - - - - - / .-/ - - - — I — — — — — — — — I -- - - - - - - - - - - -
8 - - i- j �- /- — � - � --- T -- ---
�d
I I � I /. '� �' -- -- — ---
� I - I I / a .' I /�-�' I I TYP
\ _ / / i' � I 8" CONCRETE STEM WALL
\
i'/ / \ ' ° \ / / a . / / ' / ON 16"x8" CONCRETE FOOTING
/ / i �" / I I (TYP. U.N.O.)
-'- \ /' i / j / � � �-�j
i � Y 'I O I
- i o -�" I
° d \ • .
�-� �� I ,� I/ �� /� i I I I S 1
i'
a 1
/ ° i'
/-
�- o, I �- S \ . ° .�/I / I � / I I CR WLSPACE I
10 � I I I / � I / I I 6 IL. BLACK �.B.
I, I �� \ I / �-� � I I I
I I \ I �'' / I I I I I
I Q'- ���-' / I i I I I
�/4 T � �I
I I -
- - - - - I - - �- - - - I - - -�- I - - - - I - - I - - - - - - - ; � �
8 I I ' I I I I F-04 I A8
I I �'� I i I I�I, � I
CONCRETE LANDING &STEPS /�i"/ i i o i i � - � - M .
TO GRADE PER,LR.C. � I I
I, �- I a I � I I I I I
�-' I � I i I I � I � I
��,�" I I i I � I� I
,�- I I I I I I
i'' I I I I I I F-03 l
I
'- i 3 i 10
-�' I,
S1 S7 �p I
i SIM i � I 11 � I I
'� I
o �'� 'I, I I I - I S� I I
N
-'" I i i i CRI WLSPACE I I I
�- � i 10° I i � I I -
� i 6iMIL. BLACK V.B. i "oho � I .
� I
�"� I, I I i I I I, I
�''- i i i i I, CRAWLSPACE I
," 6 MIL. BLACK V.B.
i yO'4 I � i i II •'`�
I i I i L iJ j I
', i i i i i I, I
I 9'-6° '� I i I I I
I ors g• I � I � I I I
-- I --- �---I— � I L- I --- � I —� I, I I.
6 � -- - ----- A CESS a � ----- - --- � N-----------� �---------------------------
-----d !•� -- —� — -- —L° L---- ---� I
� � I � ` I � �I� N � � I � I
w—i_—_—_—_—_—_—_ ap�'_—_ _—_—_—_���_——_—_—_—_ _ � _ _—_—_—_—_ _—_—_i .
rJ _ _- -_ _-_-_-_-_-_-_-_-_-_-_-_-_-_-� _I,I__t_-_-_ -{ II r _-_-_-_ — — — — — — _-_-_-_-_-_-_-_-
c� I
Q � �aS.Q w 1 it 3 a 5$ ,e.
� i 9'-1" i, \ 6'-1/a" T-3/a" 4'-7/" 18'-4%"
w
a'. I
II GA�DEN SLAB � �° I � ��� II ���
�:I
4" CONC. iSLA6. SLOPE MIN. 8" ' f- I •."
o PER 1'-0" T WARDS GARAGE D00� i i - I i I;°; I
— — — _ ��� si I I I
`° � � � i � i�� i GARAGE SLAB I
N
PER 1'-0' TO ARDS GARAGE DOORS. I
°�� ! CRAWLSPACE � I I �
��� 6 MIL. BLACK V.B. °�, I
� 5 I I I I
3 i F-o2 �', I i i I
I I° i TYP _ _ S1 I I I 12
I i i S1
�I S1 I i i, � _o — — J I I
6] � N
- - - - - - - - - - - - -- - --- -- - -- - - - - � - - --- - NO BOLTS -I -- --- - -- - - - - - i - - - - - - - - - - - - - - - � - - - - - - - - - - - - -
3 ��- 1 C -- rt fi - F
���°� I i i.` = sT s��°�� i i I
' F-01 � ti I I I I
I' I TYP -- I ---J �: v �iQ -
t l � I I I I
- - - - - - - - - - - - - - - - - 1 - - - - --- --- - - - - - - - - - - - - --1- -- - -L- - - - - - - - - - - - - - - - � - - - - - - - - - - - - -
2 I ' --- ---' '°'
o T CONCRETE LANDING & S EPS I � — —
N I I I I � �` I
1 I TO GRADE PER LR.0 — — — CONT. FT'G UN ER GARAGE DR. — — — — -
- + - - i- - - a - -�- - -�- - -�-- -
I I I I I I I I
I I I I I I I I
�a i � I I �� i ��
'I I I I ,�� I g I I �s I yam
'I I I 'I � I � I I � I
2'-4%" � � 18'-3" 2'-4%" i
I I I
i, 3'-6" i, 12'�0" i T-0" I, � i 23'-0" i.
FOUNDATION NOTES
• VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO COMMENCING
ANY WORK.
• GENERAL CONTRACTOR AND/OR FOUNDATION CONTRACTOR SHALL VERIFY
THE LOCATION OF ANCHOR BOLTS AND HOEDOWNS PRIOR TO POURING
CONCRETE.
• ALL FOOTING SHALL BEAR 18" BELOW UNDISTURBED NATURAL SOIL.
FINISHED GRADE SHALL BE NO LESS THAN 12" ABOVE BOTTOM OF
FOOTINGS.
• TOP OF FOOTING SHALL BE LEVEL. BOTTOM SURFACE OF FOOTING SHALL
NOT SLOPE MORE THAN 10%. STEP FOOTING AS NECESSARY TO MAINTAIN
MIN. DEPTH OF FOOTING BELOW FINISHED GRADE.
• FOUNDATION WALL SHALL EXTEND MINIMUM 6" ABOVE FINISHED GRADE.
• ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED.
• UNLESS NOTED OTHERWISE OR IN SHEAR WALL SCHEDULE, ALL ANCHOR
BOLTS SHALL BE%Z' dia. x 10" AND EXTEND MINIMUM 7" INTO CONCRETE
WITH MINIMUM SPACING OF 48" ON CENTER. EACH ANCHOR BOLT SHALL
HAVE A 3"x3"x.229" GALVANIZED WASHER.
• SEE SHEARWALL &HOEDOWN SCHEDULES FOR SIZE AND PLACEMENT.
• CRAWLSPACE ACCESS SHALL BE A MIN. OF 18"x24". OPENINGS THROUGH A
PERIMETER WALL SHALL BE NOT LESS THAN 16"x24". (R408.4)
• PROVIDE A 6 MIL. BLACK VAPOR BARRIER OVER ALL CRAWLSPACE AREAS.
(R406.3.2)
• PROVIDE 2" SAND OVER 6 MIL BLACK VAPOR BARRIER OVER 4" COMPACTED
GRANULAR FILL UNDER ALL CONCRETE SLABS.
• PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT
CONNECTIONS ARE IN PLACE.
• ALL ISOLATED SPREAD FOOTING TO BE 24"x24"x8" REINFORCE FOOTINGS
WITH (2) #4 BARS EACH WAY UNLESS NOTED OTHERWISE IN PLAN.
• FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES
AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM TOP OF
FOOTING TO FINISHED GRADE. (R406.1)
• SEE SIMPSON RECOMMENDATIONS FOR HOLD DOWN PLACEMENT.
COORDINATE LOCATIONS WITH DOOR &WINDOW ROUGH FRAMING TO
PROVIDE ACCURATE DIMENSION FOR OPENINGS.
FOUNDATION VENT CALCS.
(R408.1)
THE MINIMUM NET AREA OF VENTILATION OPENINGS SHALL NOT BE LESS THAN 1
SQUARE FOOT FOR EACH 300 SQUARE FEET OF UNDER -FLOOR AREA. REQUIRED
OPENINGS SHALL BE EVENLY PLACED TO PROVIDE CROSS VENTILATION OF THE
SPACE EXCEPT ONE SIDE OF THE BUILDING SHALL BE PERMITTED TO HAVE NO
VENTILATION OPENINGS.
ASSUMED VENTS ARE MIN. 15.5"x6" AND HAVE A NET FREE VENTILATION AREA
OF .48 SQ. FT.
FOUNDATION VENT CALCULATIONS
CRAWLSPACE AREA 1455 SQ FT
NET VENTILATION
AREA / 300 SQ FT 4.85 NET AREA
NUMBER OF VENTS REQ'D
NETAREA/ 0.48 11
OPTIONAL POWER VENT
CRAWLSPACE HEIGHT 3 291 CFM
NOTE !
ALL FOUNDATION WALLS
TO BE 8" UNLESS CALLED OUT
OTHERWISE.
LEGEND
STEM WALL
— —FOOTING
CONCRETE SLAB
CONCRETE FOOTING SCHEDULE
SYM.
FOOTING SIZE
RE -BAR
PLACEMENT
F-01
'16"x8" CON'T.
(2) #4 CON'T.
F-02
24"x24"x8"
(2) #4 EA. WY.
F-03
16"x8" CON'T.
(2) #4 CON'T.
F-04
30"x30"x8"
(3) #4 EA. WY.
F-05
22"x8" CON'T.
(3) #4 CON'T.
F-06
SEE 12/S1
NOTE:
'EXTERIOR FOOTINGS SHALL BE MIN.
18" BELOW GRADE AND REST ON
BEARING SOIL.
FOUNDATION PLAN
SCALE: 1 /4" = 1'-0"
U
z
N
W
Z >Q O
Q U
Y 2 0�
w a '�n
w��
� � a
O "��
J V �
U ��o
z °�
W N ..
W
IOC o °Ei
W m
� o
W
O
C
-�' tii
.�
C
N
} F o '°'o � a m �° � m� a `` � c o
N Q O � o d o-U — �� E� O O n n.
���aoa�o@����o��o�
� O J N � d -o n@ m m p 'o m� m E
�Oms�.���fOON��'Tm�__E�
} W¢ w U � `� � U N O) � N y O
OWLL °w�o3�>. ti-�n o�c3a�No
W _ n n
=gomap'ias °����'>s End
~ J Q ` U 0� O H O
4.30.2023
y p,N N. RCS
�
of W ASyiN S
�Z
�n
J B#
2 02
��
46411 �
'�FGISTER�� \��
SS�ONAL �-�G
ELECTRONIC COPY
ORIGINAL
ON FILE AT
ROSS ENGIN�Ijj�G�FSI��
W May 17 2023
V CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
W
�
N
W
Il� �
h �
O O
� �
� �
W W
�
a
� �
�
�
z
i i
W
Z Z
W
�
� � �
a
z0 O
o
wO zO �'�
� � � � �
o a
M
�
0
c
0
c`�
z
PROJECT NO.
210905
DESIGNED BY
TL
DRAWN BY
TL & RM
CHECKED BY
TL
SHEET:
PRINT DATE 4/29/2023 10:06 AM
A B C D E F G H
I I I I I �'� I I I
�I I I �I I � �� I �I I
I I I I I /� I I I
�'
�'
�'
i�
��
10
E
-------
L
•.A
�'
�'
��
��
�'
9
---
---
BEAM SCHEDULE
SYM.
BEAM
BM-01
4x8 DF#2 OR BETTER
BM-02
4x10 DF#2 OR BETTER
BM-03
1.75"x11.875" LVL
BM-04
3.5"x11.875" PSL
BM-05
(2) 2x12 HF#2
BM-06
4x12 DF#2
BM-07
5.5"x16.5"GLULAM
BM-08
5.5"x18"GLULAM
BM-09
6.75"x18" GLULAM
BM-10
5.5"x13.5"GLULAM
BM-11
3.5"x10.5"GLULAM
NOTE !
P L.
POINT LOAD ABOVE.
SOLID BLOCKING REQUIRED IN
FLOOR FRAMING
NOTE !
ALL 1ST FLOOR FRAMING MEMBERS
TO BE 2x12 DF#2 @ 16" O.C. (U.N.O.)
LEGEND
CONCRETE WALL UNDER
}'^ WALLS UNDER
.............
WALLS/ FIXTURES OVER
FLOOR PERIMETER
FLOOR JOISTS
HEADERS &BEAMS
CONCRETE SLAB
1ST FLOOR FRAMING
SCALE: 1/4" = 1'-0"
V
z
N
W
Z
>Q O
QU
� 1' 2 rn
wa��,
��v
"��
O
J
J V �
U ���
0
M � w
Z ANC
W � ��
� o
W m
� a
W
H
u
,K ,�'
�.�
"/ 4s�c:.
N
,'�
��
��
C
"' II �
�
� i,
L
' �_
ai
CC L�� •■
.y
Z H O V .0 N r` O L�� a �� C 0
N} owcctidE�a� cm'-
�QZyc`-'��°aU ca���o°aa
2
.. .- c � m y 2
� U m L f0 N @ O y� L =� f0 USE N
aw�'�U c y c � a`�i� o d d a`-' o 0
UwO
nam`o mJOQ��O ?�o°
v w d � w t aEi �� o� E� m
��
J Q O �
4.30.2023
y PN N' RCS
�
OF WgS,y�N s,
��
ti o
H � B#
2 02
��
46411 �
�FGISTER�-0 \��
SS�ONAI. �-�G
ELECTRONIC COPY
ORIGINAL
ON FILE AT
ROSS ENGIN�R�LC�F,S��
W May 17 2023
V CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
W
� y
t/>
� H
h H
O O
� J
J �
W W
c,
a
� �
�
oI� df
o
� �
o
_ =
o
W
� �
Z Z
W
�
� �
�
z0 O
a
o
u O z O N�
w
Q
� � � � �
�
M
O Q
n
0
0
•L
N
m
0
C
Z
PROJECT NO.
210905
DESIGNED BY
TL
DRAWN BY
TL & RM
CHECKED BY
TL
SHEET:
PRINT DATE 4/30/2023 3:22 PM
A 6 C D
1
�A8�
�'
�'
�,�
�'
�'
9
0
2
1
F G H
1
�A8/
r��
I .:'I
I `1
I' ''1
I.; '. I
I. I
I . ' .,
r.•;I
I....: I
I , I
I': 'I
L :I
I'a
I I
I;.'I
�_—L
I. .'I
I, �; J
F,:. I
I;.. i
I ai
I `; 'I
1. I
�:
I: �i
I `.' a
�' `-�
I•
I•,. :�
r:I
I`,%. I
r..�
�_:-�
t I
G':I
r .I
4' : 1
I :•:. I
I ... I
I',:.I
I..; i
G:: <i
I .:`I
I-. 'I
I .' .
I •' .
---��---
BEAM SCHEDULE
SYM.
BEAM
BM-01
4x8 DF#2 OR BETTER
BM-02
4x10 DF#2 OR BETTER
BM-03
1.75"x11.875" LVL
BM-04
3.5"x11.875" PSL
BM-05
(2) 2x12 HF#2
BM-06
4x12 DF#2
BM-07
5.5"x16.5"GLULAM
BM-08
5.5"x18"GLULAM
BM-09
6.75"x18" GLULAM
BM-10
5.5"x13.5"GLULAM
BM-11
3.5"x10.5"GLULAM
NOTE !
P L.
POINT LOAD ABOVE.
SOLID BLOCKING REQUIRED IN
FLOOR FRAMING
NOTE !
ALL ROOF FRAMING MEMBERS TO BE
MANUFACTURED TRUSSES
HEADER NOTE !
HEADERS NOT CALLED
OUT IN PLAN SHALL BE:
A �'�
\�� BM-01 Q�
LEGEND
TRUSSES
--------- TRUSSES (TOP CHORD)
RAFTERS
�������������������������� OVER FRAMING
WALLS UNDER
WALLS/ FIXTURES OVER
HEADERS &BEAMS
FLOOR PERIMETER
FLOOR JOISTS
LANDING JOISTS
STAIR STRINGERS
LOWER ROOF LINES
LOWER ROOF VENT CALCULATIONS
1281 SQ FT
REQUIRED ROOF VENTILATION
AREA / 300 4.27 SQ FT
40-50% IN UPPER &LOWER ROOF
ROOF VENT AREA / 2 2.14 SQ FT
VENT BLOCKS IN EAVES
BLOCKS =AREA/ 0.074 29
ROOF VENTS IN UPPER 40-50
OPTION 1:
AF50 ROOF JACK =AREA / 0.333 7
OPTION 2: (ridge vent)
CORAVENT V300 =AREA/ 0.094 22.7 FEET
2ND FLOOR FRAMING
SCALE: 1/4" = 1'-0"
FLOOR TRUSS NOTE:
THIS LAYOUT IS FOR SCHEMATIC PURPOSES ONLY.
REFER TO TRUSS FRAMING PLANS PER MANUFACTURER
AND PREPARED BY A LICENSED TRUSS ENGINEER.
V
z
N
W
Z
>Q O
QU
� 1' 2 rn
wa��,
��v
"��
O
J
J V �
U ���
0
M � w
Z ANC
W � ��
� O °�'
W m
� a
W
H
u
,K ,�'
�.�
/� "!,, + rn
"/ 4s�c:.
N
,'�
��
��
C
"' II �
�
� i,
L
' �_
ai
CC L�� •■
.y
Z H O V .0 N r` O L�� a �� C 0
N} owcctidE�a� cm'-
�QZyc`-'��°aU ca���o°aa
2
.. .- c � m y 2
� U m L f0 N @ O y� L =� f0 USE N
aw�'�U c y c � a`�i� o d d a`-' ° o
UwO
narn`o mJOQ��O ?�o°
v w d � w t aEi �� o� E� m
��
J Q O �
4.30.2023
yPNN.R�s
�
of wasyiN s
�i
�
J B#
2 02
��
46411 �
'�F6ISTER�� \��
SS�ONAL �-�G
ELECTRONIC COPY
ORIGINAL
ON FILE AT
ROSS ENGIN�f�G�F„SI��
W May 17 2023
V CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Z
W
� y
t/>
� H
h H
O O
� J
J �
W W
c,
a
O
TH T�
i Z
�
w
� �
Z Z
1[-
W
�
� �
a
�
z O O
�
w
u O z O �'
�
Q
� � � � �
�
M
O Q
1�
0
0
•L
m
0
Z
PROJECT NO.
210905
DESIGNED BY
TL
DRAWN BY
TL & RM
CHECKED BY
TL
SHEET:
PRINT DATE 4/29/2023 10:07 AM
ROOF PLAN NOTES
• SEE DESIGN LOADS AND/OR STRUCTURAL NOTES FOR
GROUND AND ROOF SNOW LOADS.
• FOR MANUFACTUREDED TRUSS ROOFS: ROOF PLAN IS FOR
SCHEMATIC PURPOSES ONLY. ACTUAL ROOF PLAN TO BE
DESIGNED AND ENGINEERED BY A LICENSED TRUSS
ENGINEER. RAFTER FRAMING PER PLAN.
• TRUSS LAYOUT TO BE REVIEWED AND APPROVED BY THE
TRUSS MANUFACTURER PRIOR TO CONSTRUCTION.
• LOCATE DOWNSPOUTS PER SITE CONDITIONS AND PER
GENERAL CONTRACTOR.
• INSTALLATION OF ALL ROOFING AND WALL FLASHING
SHALL BE TO INDUSTRY STANDARDS AND IN COMPLIANCE
WITH CURRENT CODES.
• PROVIDE CONTINUOUS ALUMINUM GUTTERS ON FASCIA AS
SPECIFIED IN DETAILS.
• SKYLIGHT SIZES, IF ANY, ARE APPROXIMATE. CONTRACTOR
TO VERIFY ACTUAL ROUGH OPENING SIZE PER
MANUFACTURER SPECIFICATIONS.
• PROVIDE SOLID BLOCKING OVER ALL SUPPORTS.
• PROVIDE MIN. 22"x30" ATTIC ACCESS WITH APPROVED
WEATHERSTRIPPING. IF ACCESS IS IN A GARAGE, A SELF
CLOSING MECHANISM MUST BE INCORPORATED.
• 16d @ 8"o.c. END TRUSS TO TOP PLATES. (TYPICAL AT ALL
GABLE ENDS)
• ATTICS WHERE THE MAX. CLEAR HEIGHT BETWEEN JOIST
AND RAFTERS IS MORE THAN 42", OR WHERE THERE ARE
TWO OR MORE ADJACENT TRUSSES WITH THE SAME WEB
CONFIGURATION CAPABLE OF CONTAINING A RECTANGLE
42" HIGH BY 24" WIDE OR GREATER, MUST BE CONSIDERED
ATTIC WITH LIMITED STORAGE.
• ATTIC SPACE SERVED BY A FIXED STAIR SHALL BE
DESIGNED TO SUPPORT THE MIN. LIVE LOAD FOR SLEEPING
ROOMS.
ATTIC VENTILATION CALCULATIONS
ATTIC VENTILATION (R806.1 & 806.2)
PROVIDE 1 SQ. FT. OF ATTIC VENTILATION FOR EACH 150 SQ. FT. OF
ATTIC AREA.
EXCEPTION:
PROVIDE 1 SQ. FT. OF ATTIC VENTILATION FOR EACH 300 SQ. FT. OF
ATTIC SPACE WHEN NOT LESS THAN 40%AND NOT MORE THAN 50%
OF THE REQUIRED VENTILATION AREA IS PROVIDED BY VENTILATORS
LOCATED WITHIN THE UPPER PORTION OF THE ATTIC OR RAFTER
SPACE. UPPER VENTILATORS SHALL BE LOCATED NOT MORE THAN 3
FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACED
MEASURED VERTICALLY WITH THE BALANCE OF THE REQUIRED
VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE
LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH
THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION OF MORE
THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE
SHALL BE PERMITTED.
UPPER ROOF VENT CALCULATIONS
ROOF AREA
1429 SO FT
REQUIRED ROOF VENTILATION
AREA/ 300
4.76 SQ FT
40-50% IN UPPER &LOWER ROOF
ROOF VENT AREA/ 2
2.38 SQ FT
VENT BLOCKS IN EAVES
BLOCKS =AREA / 0.074
33
ROOF VENTS IN UPPER 40-50
OPTION 1:
AF50 ROOF JACK =AREA / 0.333
8
OPTION 2: (ridge vent)
CORAVENT V300 =AREA/ 0.094
25.3 FEET
A B C D
I,
I I I I
E F G H
I �'� I I I
-'- I, I,
I �-� I I I
I ,/ I I I
�''� i i I, i BEAM SCHEDULE
I, i i i�-'� i i I,
I I I �-I� I I I �' I sYM. BEAM
�' �'� BM-01 4x8 DF#2 OR BETTER
,-
i'/ �'� BM-02 4x10 DF#2 OR BETTER
-� BM-03 1.75"x11.875" LVL
i' �'
,� ,' BM-04 3.5"x11.875" PSL
I I L/ I I I I �' I
i'/ � i BM-05 (2) 2x12 HF#2
�'� � / BM-06 4x12 DF#2
�-� � BM-07 5.5"x16.5" GLULAM
i'
I � I I I I I / I
��� �-� BM-08 5.5"x18" GLULAM
�r� I I I I �d� I BM-09 6.75"x18" GLULAM
� I I I I I BM-10 5.5"x13.5" GLULAM
�' �'
,� I I I I I �� I I BM-11 3.5"x10.5" GLULAM
8 - - - - - - - - - - - - - - - - - - - iT-- - - I- - - - - - - - 1 - - - - - - -�- - - - - - - - --I- --- - - - - - -� - - - -fi- - - - - - - - - - - - - - - -fi- --- - -- - -- - ---
�'� I I I I I �'� I I
i'
i'
i'
i'
i'
�'
i'
i'
i'
i'
i'
i'
i'
i"
i"
i'
10
i"
/,i
i'
i'
�'
�'
i'
i'
i'
i
i'
i'
i'
i'
�-
��
9 ��
2
1
----- �PJ
a
NOTE !
ALL ROOF FRAMING MEMBERS TO BE
MANUFACTURED TRUSSES
HEADER NOTE !
HEADERS NOT CALLED
OUT IN PLAN SHALL BE:
A 0'�
\�� BM-01 Q�
LEGEND
TRUSSES
TRUSSES (TOP CHORD)
•••••••••••••••••••••••••• OVER FRAMING
GIRDER TRUSS
WALLS UNDER
HEADERS &BEAMS
ROOF LINES
LOWER ROOF LINES
ROOF PLAN
SCALE: 1/4" = 1'-0"
FOR SCHEMATIC PURPOSES ONLY.
REFER TO TRUSS FRAMING PLANS PER MANUFACTURER
AND PREPARED BY A LICENSED TRUSS ENGINEER.
U
z
N
W
Z >Q O
Q U
Y 2 0�
w a '�n
w��
� � a
O "��
J V �
U ��o
z °�
W N ..
W
pC o °E'
W m
� o
W
H
c°�
c
-�- .cii
C
N
tiw a°�i �.w � =g �-o c o `o 0
Z O E� .N a L �� c m c� c w .-
o Q� � �'� o o=�� m� o m a a
H�� o_ o n t o= g a ��"�� o 0
C=70�w Ada o.m �°ma-o m�mE
� U m y m <° '" � o N� s �'T m i�� E �
} W¢�� y y� U m O) � N y O
O W LL ° w � 0 3 a�i >. ti o� c 3 a :6 � o
UFO o � map J aa.a mOin� o
w_ aa�
���Na��i`o�sm��aF��a�
�¢ o�
4.30.2023
yPNN.R�s
� OF WgSy�N S
CJ,
�i Z
J B#
2 02
46411 �
��
ss�ISTER��G���
�4NAL
ELECTRONIC COPY
ORIGINAL ON FILE AT
ROSS ENGIN�i��.Sl��
W May 17 2023
V CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Z
W
� N
W
DC �
O O
� �
� �
O
�
W W
a
� �
�
i i
W
- -
Z Z
W
� � �
a
z O O
0
w O Z O N�
� � � � �
� O ¢
M
n
a
0
c
0
Q
.�
N
O
Z
PROJECT NO.
210905
DESIGNED BY
TL
DRAWN BY
TL & RM
CHECKED BY
TL
SHEET:
PRINT DATE 4/29/2023 10:07 AM
DIAPHRAGM NAILING SCHEDULE
NAIL SPACING
NAIL SPACING AT
AT BOUNDARIES
INTERMEDIATE
NAIL SPACING
BLKG
SIZE OF
AND "OTHER"
FRAMING
AT BLOCKED
LOCATION
SHEATHING
REQD
NAIL
PANEL EDGES
MEMBERS
PANEL JOINTS
ROOF
SEE STRUCT
NOTES
NO
lOd
6" OC
12" OC
6" OC
SUB-FLR
NO
10d &GLUE
6" OC
12" OC
6" OC
DIAPHRAGM NOTES
1.
ALL DIAPHRAGM SHEATHING IS TO BE STAGGERED IN THE DIRECTION OF
THE PLYWOOD SPAN PER
DIAPHRAGM DETAIL
2.
PROVIDE BOUNDARY NAILING CONTINUOUS AROUND THE ENTIRE
PERIMETER
OF THE DIAPHRAGM
3.
NAILS SHALL BE COMMON OR GALVANIZED BOX
4.
ALL FRAMING MEMBERS SHALL BE 2x MINIMUM NOMINAL WIDTH
BLOCKED DIAPHRAGM
TYPICAL CONTINUOUS
WHERE INDICATED
PAN EL JOINT
11 li 17 d
I. IJ CI IJ
a
I:
11
BOUNDARY
'I 11 11 11 11�
W rl IJ
il�
11
NAILING
� � 11 li 'r
li
11
11 TOP PLATE
II al:
II .I.
II
IJ
BLOCKED CONTINUOUS
�I �I:
11 11
IJ
la Ij
li
"OTHER" PANEL
PANEL JOINT
EDGE NAILING
li li
�� FI ��
]I:
w
��:
INTERMEDIATE
JOIST/TRUSS
NAILING
DIAPHRAGM DETAIL
TYPICAL DIAPHRAGM NAILING � 1
C~
.J
11
16
TOP PL
NOTES:
SEE STRUCTURAL NOTES FOR TYPICAL TOP
PLATE NAILING NOT SHOWN
TYPICAL TOP PLATE SPLICE � 2
7
12
17
CRIPPLE STUDS AT
16" O.C. WHERE APPLICABLE
TOP PLATES
NAIL STUD TO HEADER
W/ (8) 16d
STUDS) PER PLAN
FULL HEIGHT
TO TOP PLATES
TRIM STUDS (TRIMMERS)
PER POST PLAN
#4
M,
RE
TRUSS
f
16d
CANTIL
SD
ROOFBOUI�'^""" "'""'""'
2x CC
WITF
ROOF TRU
SHEAR WALI
SOLID BLKG MATCH
WIDTH OF BEAM/GIRDER
TYPICAL HEADER DETAIL $
TYPICAL FOOTING STEP � $
IDARY NAILING
TOP BEARING TRUSS
ON CANTILEVERED
BEAM
SECTION � 13
2x CONT. BLOCKING
WALL STUDS PER PLAN
NOTCH TRUSS OVER
LEDGER
2x12 DF#2 LEDGER
WITH (2) SDS25412 AT
12" o.c.
SECTION 18
NOTES:
1. USE THIS DETAIL AT ALL LOCATIONS WHERE
BEAM WIDTH EXCEEDS 3%" AND/OR BEAM
BOTTOM BEARING IS BELOW DOUBLE TOP
PLATES.
2. EXTEND BEAMS FOR 5-1/2" BEARING ON 2x6
WALLS, 3-1/2" BEARING ON 2x4 WALLS.
STUD WAL
ROOFBOUNDAR
RAFTERS
HANGERS
SON CS16 WITH (20)
�O DBL. TOP PLATE
D AT EACH SIDE.
JI AS NEEDED.
�� f PER PLAN
TYPICAL PLATE STRAP AT BEAMS � 4
t4 VERT AT END OF WALL
t4 CONT. AT TOP OF WALL
CONCRETE FOUNDATION
WALL PER PLAN
(TYPICAL REINFORCING
NOT SHOWN FOR CLARITY
TYPICAL CONCRETE WALL STEP � 9
2x12 LEDGER WITH
SDS25412 AT 16" o.c.
SECTION � 14
19
II II
I I ROOF TRUSSES/ -�! I
I I RAFTERS BELOW I I_ _ _ _ _
I I ��
I I
2x6 BLOCK BETWEEN `��_ _ _ _
ROOF TRUSSES BELOW W/ I I
(2) 16d EA END I I �
i
2x6 PLATE W/ (2) 16d I I � � /
INTO EA ROOF TRUSS I I i
BELOW I I�
i
I I
I I
2x4 RAFTERS @ 24"o.c. i I I
POST DOWN TO ROOF � i / I I �
TRUSS BELOW AT 24" o.c. � I I ao
II � II m
I I �� I I �
I I i I I �
I I �� I I �
I I / I I `�
I I �� I I
I I �
I I'
_ _
_ _ _
�
_ _
II
I I
I I
_�
I I
�r
I I
I I
I I
�
I
�
I
�
I I
�
I I
� .
TYPICAL ROOF OVERFRAMING I rj
LAP JOIST OVER BEARING MIN. 6"
AND NAIL WITH (3) 10d
FLOOR JOISTS PER PLAN
2x CONT. BLOCKING
OVER BEAM
VAPOR BARRIER PER
ARCHITECTURAL
m
ROOFBOUT'^""" "'""'""'
2x CC
WITF
ROOFTRU
SHEAR WALL
FLOOR SHEATHING PER
STRUCTURAL NOTES
IP�1�1�_\�[�l��l�:�_1:Zy71��i�r11:%LI
2x6 PONY WALL WITH
STUDS AT 16" o.c.
CONT. 2x BLOCKING
ATMID-HEIGHT
2x SILL PT SILL PLATE
WITH 1/Z" DIA. ANCHOR
BOLTS AT 48" o.c.
FOOTING WITH
REINFORCING PER PLAN
FINISHED GRADE
CRAWL SPACE SECTION � 10
SEE 20/S8 FOR SHEAR
WALL CONNECTIONS
NOT SHOWN
NG
1 %" RIM JOIST
FLOOR SHEATHING PER
STRUCTURAL NOTES TYP
FLOOR JOISTS PER PLAN
SECTION � 15
20
Ross
Engineering
Design
Inc
rya n. ross@ rosseng i neer.com
4.30.2023
yPNN.R�s
� pF WAS,yi,�, S
�z
�
J B#
2 02
46411 �
�� 'QfGISTER�� \��
SS�ON AL ��v
ELECTRONIC COPY
ORIGINAL ON FILE AT
ROSS ENGINEERING DESIGN
RESUB
�I ay 17 2023
� CITY OF EDMONDS
LOPMENT SERVICES
ZDEPARTMENT
W
� H
H �
W
� H
� �
� �
O O
�
� �
� �
O
�
W W
a
LL LL
0
T� T�
i i
�
W
Z Z
W
� �
Q
Z O O
a
w O Z O
� 0
� �
� Q
�
O� 1� � 1�
V O V
�
Q �
a�
0
0
�.
�L
V
N
d
O
Z
FILE/ NO.
20000
DESIGNED BY
RR
DRAWN BY
RR
CHECKED BY
RR
SHEET:
PRINT DATE 4 / 26 / 2023
1
C~
��
11
16
TYPICAL SHEAR WALL SCHEDULE
NUMBER OF
SHEAR WALL
STUD/BLKG.
SILL PLATE /SOLE PLATE
FRAMING
ANCHOR TO
NAIL/SCREW
�, z
SHEATHED
EDGE s
AT ADJOINING
s 9
SYMBOL
SHEATHING
SIDES
NAILING
PANEL EDGES s
SIZE
CONCRETE '
TO RIM JOIST
SHEAR CLIPS
SW1, SW1P
1
8d @ 6" OC
2x
2x
5/8" DIA. AB
3"x.131" NAIL
3"x.131" TOENAIL
io
@ 48" OC
@ 6" OC
@ 6" OC
SW2, SW2P
1
8d @ 6" OC
2x
2x
5/8" DIA. AB
16d BOX NAIL
LTP4 @ 24" OC
SEE
STRUCT
@ 48" OC
@ 6' OC
SW3, SW3P
1
8d @ 4" OC
2x
2x
5/8" DIA. AB
16d BOX NAIL
LTP4 @ 18" OC
NOTES
@ 32" OC
@ 4' OC
SW4, SW4P
1
1
2
8d @ 3" OC4
8d @ 2" OC4
8d @ 3" OC4
3x OR DBL. 2x6
3x OR DBL. 2x6
3x OR DBL. 2x6
2x
2x
3x
5/8" DIA. AB
@ 24" OC
5/8" DIA. AB
@ 18" OC
5/8" DIA. AB
16d BOX NA4L
@ 3' OC
16d BOX NA4L
@ 2.5" OC
SDS25600
LTP4 @ 14" OC
LTP4 @ 10" OC
LTP4 @ 14" OC
SWS, SWSP
SW6, SW6P11
@ 18" OC
@ 5" o.c.
EA. FACE
SHEAR WALL SCHEDULE NOTES
1. SHEAR WALLS NOTED AS "SW_" INDICATE "SEGMENTAL SHEAR WALL" PER DETAIL (RIGHT)
2. SHEAR WALLS NOTED AS "SW P" INDICATE "PERFORATED SHEAR WALL" PER DETAIL (RIGHT). APPLY ALL SHEATHING, NAILING AND FRAMING REQUIREMEN
PER SCHEDULE TO THE FULL LENGTH OF SHEAR WALL INCLUDING AREAS ABOVE AND BELOW OPENINGS.
3. NAILS SHALL BE COMMON OR GALVANIZED BOX UNLESS NOTED OTHERWISE.
4. WHERE NAIL SPACING IS LESS THAN 4"oc, STAGGER NAILS %".
5. ALIGN ALL VERTICAL ADJOINING PANEL EDGES WITH STUD PER SCHEDULE. PROVIDE BLOCKING PER SCHEDULE AT ALL HORIZONTAL ADJOINING PANEL EDGE
6. 3x FRAMING MAY BE SUBSTITUTED WITH (2)2x NAILED TOGETHER W/ 16d MATCHING EDGE NAIL SPACING. STAGGER PER NOTE #4.
7. AT SW1 PROVIDE STANDARD CUT WASHERS AT ALL SILL BOLTS. AT SW2 AND HIGHER PROVIDE 3"x3"x%4" STEEL PLATE WASHERS. LOCATE EDGE OF WASHER
WITHIN �" OF EDGE OF SHEATHED SIDE OF SILL PLATE. HOLE IN WASHER MAY BE DIAGONALLY SLOTTED 1.75" MAX.
8. ENSURE ONE CLIP EACH END OF SHEAR WALL AT EACH REQUIRED FACE OF SHEATHING.
9. SHEAR CLIPS ARE REQUIRED ONLY AS INDICATED IN THE SECTIONS.
10. SEE DETAIL (TOP FAR RIGHT) FOR TYPICALTOENAIL
11. SEE DETAIL (BOTTOM FAR RIGHT) FOR BLOCKING, NAILING AND SHEAR CLIP REQUIREMENTS AT DOUBLE SIDED SHEAR WALL
7
12
17
ROOF SHEATHING PER
STRUCTURAL NOTES
ROOF BOUNDARY NAILING
2x BLOCKING PANELS PROVIDED
BY TRUSS MANUFACTURER
SHEAR WALL SHEAR CLIPS
EDGE NAILING
SHEAR WALL PER PLAN
S��X
SHEAR CLIPS PER SHEAR WALL
SCHEDULE WHERE APPLICABLE TYP.
SQUASH BLOCKS IN RIM JOISTS AT
ALL POSTS AND HOLD-DOWNS, ALL
LEVELS. SEE TYPICAL POST BLKG.
DETAIL TYP.
ANCHOR TYPE HOLD-DOWN W/
ANCHOR ROD PER HOLD-DOWN
SCHEDULE TYP.
8d AT 12" o.c. NAILING AT ALL
INTERMEDIATE SUPPORTS
TS PANEL EDGE NAILING TYP.
SILL/SOLE PLATE W/
ANCHORS PER SCHED. TYP.
S.
ANCHOR TYPE HOLD-DOWN
PER PLAN WHERE APPLICABLE.
SEE SCHEDULE FOR ANCHOR
ROD TYP.
/� SDHEAR WALL O��
SW_ % 1
SHEAR WALL KEY
SEGMENTAL SHEAR WALL
ROOF TRUSSES PER PLAN
H1 CLIP EACH TRUSS
SHEAR WALL AT RAISED TRUSS HEEL � $
SOLE PLATE NAIL/SCREW
EDGE NAILING
EDGE NAILING TO RIM JOIST
FLOOR BOUNDARY NAILING
EXTEND LOWER SHEAR WALL
SHEATHING CONT. OVER RIM
JOIST. DO NOT BREAK AT
DOUBLE TOP PLATE.
EDGE NAILING TO TOP PLATE
FLOOR SHEATHING PER
STRUCTURAL NOTES
CONT RIM JOIST
FLOOR JOIST/BLOCKING
PER PLAN
ALTERNATE SHEAR FLOW AT UPPER FLOORS 13
SOLE PLATE NAIL/
EDGED
EXTEND SHEAR WALL SHE,
CONT. OVER RIM JOIST. [
BREAK AT SOLE
SHEAR WALL EDGE NAZI
RIM JOIST AND SIL
FLOOR BOUNDARY NAILING
PER DIAPHRAGM SCHED
2x SILL PLATE
FLOOR JOIST
�E:
SIMILAR SECTION PER
i8 FOR INFORMATION
SHOWN
ROOF BOUNDARY NAILING
CONT. 2x BLKG WITH VENTING PER
ARCHITECTURAL. SEE 8/S8 FOR
ALTERNATE AT RAISED TRUSS
HEELS.
EDGE NAILING �
SHEAR WALL PER PLAN TYP
SOLE PLATE NAIL/SCREW
EDGE NAILING
FLOOR BOUNDARY NAILING
2x RIM JOIST
SHEAR WALL SHEAR CLIPS,
OR ALTERNATE PER 13/S8
EDGE NAILING
SOLE PLATE NA
EDG
FLOOR BOUNDAR
2xl
SHEAR WALLSHI
OR ALTERNATE
STN�X
HOLD-DOWN I�
BLKG PER SCHED AT HORIZ.
PANEL JOINTSw/EDGE
NAILING BOTH SIDES OF
JOINT TYP.
LOCATE VERTICAL PANEL
JOINT ONSTUD w/EDGE
NAILING BOTH SIDES OF
JOINT
MIN (2) STUDS AT EACH
HOLD-DOWN UNLESS
NOTED OTHERWISE PER
PLAN OR POST
SCHEDULE TYP.
STRAP TYPE HOLD-DOWN
PER PLAN TYP.
SW_P
SHEAR WALL KEY
PERFORATED SHEAR WALL
ROOF SHEATHING PER
STRUCTURAL NOTES
ROOF TRUSSES PER PLAN
H1 CLIP EACH TRUSS
2x6 STUDS AT 16" o.c.
TYP
FLOOR SHEATHING PER
STRUCTURAL NOTES TYP
FLOOR JOISTS PER PLAN
H�UX
HOLD-DOWN ID
STRAP TYPE HOLD-DOWN
CENTER ON RIM JOIST AT
UPPER FLOORS TYP.
PANEL EDGE NAILING
TYP.
PANEL EDGE NAILING
ALL AROUND OPEINING
m
J
TYPICAL TOENAIL
�i� BOUNDARY NAILING PER
DIAPHRAGM SCHEDULE TO
RIM JOIST AND BLOCKING
CONT RIM JOIST
PANEL EDGE NAILING SHEAR CLIP PER
TYP. SCHED. EACH FACE FLOOR FRAMING
DOUBLE SIDED SOLID BLKG. BETWEEN
SHEAR WALL PER JOIST BLKG
PLAN
SHEAR CLIPS -DOUBLE SIDED SW
SHEAR WALL SCHEDULE AND NAILING DETAIL I rj
ROOF BOUNDARY NAILING
EDGE NAILING
SHEATH TRUSS PER
SHEAR WALLSWI
EDGE NAILING
SHEAR WALL SHEAR
CLIPS
EDGE NAILING
SOLE PLATE NAIL/SCREW
EDGE NAILING
FLOOR BOUNDARY NAILING
2x RIM JOIST
SHEAR WALL SHEAR CLIPS, OR
ALTERNATE PER 13/S8
EDGE NAILING
SOLE PLATE NAIL/SCREW
EDGE NAILING
FLOOR BOUNDARY NAILING
2x RIM JOIST
PRESSURE TREATED SILL
PLATE PER SHEARWALL
SCHEDULE.
BOLT EMBED = 7" MIN. SHEAR WALL SHEAR CLIPS,
OR ALTERNATE PER 18/S8
FLOOR JOISTS PER PLAN
FOUNDATION PER PLAN
FRAMING PERPENDICULAR TO WALL FRAMING PARALLEL TO WALL
�i
TYP ROOF
TRUSS
TRUSS AND GABLE WALL
BRACING PER TRUSS
MANUFACTURER
2x6 STUDS AT 16" o.c.
TYP
ER PLAN
�8"oc
(4) 10d TO BLKG
—PRESSURE TREATED SILL
PLATE PER SHEARWALL
SCHEDULE.
BOLT EMBED = 7" MIN.
FLOOR JOISTS PER PLAN
� 2x BLKG AT 48"oc
� FOUNDATION PER PLAN
ALTERNATE SHEAR FLOW AT LOWER FLOOR 18 I TYPICAL STRUCTURAL WOOD WALL/SHEAR WALL ASSEMBLIES 12O
Ross
Engineering
Design
Inc
rya n. ross@ rosseng i neer.com
4.30.2023
y p,N N � RCS
� pE WA$yi,� s'
�Z
� i
J B#
2 02
46411 �
��
ssGISTER� �G���
�4NALE
ELECTRONIC COPY
ORIGINAL ON FILE AT
ROSS ENGINEERING DESIGN
RESUB
�I ay 17 2023
� CITY OF EDMONDS
LOPMENT SERVICES
ZDEPARTMENT
W
N
W
� H
O O
�
� �
� �
O
�
W W
a
� �
�
0
T� T�
i i
�
W
Z Z
W
� �
Q
Z O O
a
w O Z O
cn 0
� �
� Q
�
O�� 11�� � 1�
V O V
�
Q �
a�
0
0
�.
�L
V
N
m
0
G
Z
FILE/ NO.
20000
DESIGNED BY
RR
DRAWN BY
RR
CHECKED BY
RR
SHEET:
PRINT DATE 4 / 26 / 2023