REVIEWED-RESUB1 BLD2022-1279+Energy-HEATING _Calculations+5.17.2023_3.09.22_PM+3552072simple mating system size: tnfasnington state This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information GOODNIGHT RESIDENCE BRIAN GOODNIGHT EDMONDS, WA98020 Heating System Type: 0 All other systems O Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (AT) Edmonds AT = Indoor (70 degrees) - Outdoor Design Temp A' ^F Buildina Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 2,578 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 9.1 23,460 Glazing and Doors U-Factor X Area = UA Instructions u-o.za 0.280 519 145.32 Skylights U-Factor X Area = UA Instructions 0.50 0� --- Insulation Attic U-Factor X Area = UA Instructions R-49 0.026 2,157 56.08 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No Vaulted Ceilings in this project. Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions R-21Intermediate 0.056 3,645 204.12 Floors U-Factor X Area UA Instructions 0.025 1,882 47.05 R-38 Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions No Below Grade Walls in this project. 0.028 0� Slab Below Grade (see Figure 1) F-Factor X Length UA Instructions No Below in � 0.303 0� --- Slab Grade this project. molk— Slab on Grade (see Figure 1) F-Factor X Length UA Instructions O No Slab on Grade in this project. --- Location of Ducts Instructions Duct Leakage Coefficient Conditioned Space 1.00 Sum of UA 452.57 Figure 1. Above Grade RESUB May 17 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 46 ................................................. REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT Envelope Heat Load 20,818 Btu I Hour Sum of UA x AT Air Leakage Heat Load 11,655 Btu I Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 32,473 Btu I Hour Air leakage + envelope heat loss Building and Duct Heat Load 32,473 Btu I Hour Ducts in unconditioned space: sum of buildinq heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 45,462 Btu I Hour Buildinq and duct heat loss x 1.40 for forced air furnace Buildinq and duct heat loss x 1.25 for heat pump (07101113) N FORECAST SOLAR (425) 487-6000 Designer: Forecast Solar LLC Address: 12820 Avondale Way Everett, WA 98204 Email: info@ForecastSolar.com Customer: Brian Goodnight Address: 737 Aloha St Edmonds, WA 98020 Phone: Equipment Array Size 12kW Modules QCELL Module Wattage 40OW Module Color All Black Inverter SolarEdge Inverter Model SE-11400H Optimizer SE-P400 Racking System Sunmodo Racking Color Black Mounts EZ Comp HR250 - 5m rail HR250 - 4m rail HR250 - 3m rail HR250 - 2m rail HR250 -1 m rail Splice Kits — Grounds End Clamp Mid Clamps Site/Job Details RoofType Standing seam Roof Pitch 3:12 Azimuth 90, 180, 270 System Weight Total Array SQ FT Total PSF Weight per mount I Ibs/mount Mount Spacing 6' Maximum Wind Speed 1110 Snow Load 130