Building PermitType: RESIDENTIAL BLDG Subtype: ADDITION I Status: ISSUED
Parcel No: 00463302400203
Subdivision: 007002, 004633
Fire Sprinklers:
Valuation: $180,029.60
Code Edition: 2018
Site Address: 24110 84TH AVE W EDMONDS,WA 98026-9153
Lot: 0
Lot Area: 15918.1
Occupancy Type: R2
No. Stories: 2
Zoning: RM-2.4
Construction Type: VB
# of Dwelling Units: 1
Scope of Work: LEISER- ADDITION (GARAGE & ADD 2ND FLOOR). M INCL P SEP
WA State Contractor L & I #: SCLENL*001K4
Applied: 12/18/2023
Issued:10/21/2024
Final:
Expiration Date: 10/21/2026
Issued by: NED
CONTACTS
NAME TYPE NAME
ADDRESS
PHONE
EMAIL
APPLICANT SHAUN LEISER
60216, SHORELINE WA 98160
(206)229-6038
SHAUN@SCLENTERPRISES.NET
CONTACT SCL ENTERPRISES
60216, SHORELINE WA 98160
(206)375-1478
jasonp@sclenterprises.net
CONTRACTOR SCL ENTERPRISES
PO BOX 60216, SEATTLE WA
(206)229-6078
SHAUN@SCLENTERPRISES.NET
98160
OWNER SHAUN C LEISER
PO BOX 60216, SEATTLE WA
(206)229-6038
98160
•' •
IF
DESCRIPTION
ACCOUNT
AMOUNT
PAID
PAID DATE
RECEIPT #
AC OR HEAT PUMP - 1.75 BTU OR
001.000.345.83.000.00
$57.00
$57.00
10/21/24
R40800
LESS
BLD - RES VALUE BASED FEE
001.000.345.83.000.00
$1,586.00
$1,586.00
10/21/24
R40800
BLD - RES VALUE BASED PLAN
001.000.345.83.000.00
$1,348.10
$1,348.10
12/18/23
R33322
REVIEW
CITY TECHNOLOGY FEE - PER
001.000.321.99.100.00
$45.00
$45.00
12/18/23
R33322
PERMIT
ENG - HOURLY REVIEW - 4.1.24
001.000.345.83.400.00
$264.00
$264.00
10/21/24
R40800
ENG - INSPECTIONS - 4.1.24
001.000.345.83.400.00
$132.00
$132.00
10/21/24
R40800
FAN CONNECTED TO A SINGLE
001.000.345.83.000.00
$17.00
$17.00
10/21/24
R40800
DUCT
MECHANICAL BASE PERMIT FEE
001.000.322.10.000.00
$57.00
$57.00
10/21/24
R40800
STATE BUILDING CODE SURCHARGE
001.000.237.150
$6.50
$6.50
10/21/24
R40800
RES
TOTALS:
$3,512.60
$3,512.60
CONDITIONS
CONDITION TYPE
STATUS
NOTES
Printed: Monday, October 21, 2024 1:16:09 PM 1 of 3
'RESIDENTIAL
BLDG PermitCity
-
• • • •
EL
98020 1 •
www.edmondswa.gov•
1- HOLD HARMLESS - Applicant on behalf of his or her spouse heirs assigns and successors
in interests, agrees to indemnify defend and hold harmless the City of Edmonds,
Washington, its officials, employees, and agents from any and all claims for damages of
whatever nature, arising directly or indirectly from the issuance of this permit. Issuance
of this permit shall not be deemed to modify, waive or reduce any requirements of any
City ordinance nor limit in any way the City's ability to enforce any ordinance provision.
2 - PERMIT DISCLOSURE - Any request for alternate design, modification, variance or
other administrative deviation from adopted codes ordinances or policies must be
specifically requested in writing and be called out and identified. Processing fees for such
requests shall be established by Council and shall be paid upon submittal and are
nonrefundable.
3- SOUND OR NOISE - Sound/Noise originating from temporary construction sites as a
ALL BUILDING PERMITS
FOR
result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only
INFORMATION
during the hours of 7:OOam to 6:OOpm on weekdays and 10:OOam to 6:OOpm on
Saturdays, excluding Sundays and Federal Holidays. At all other times the noise
originating from construction sites/activities must comply with the noise limits of
Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
4 - OCCUPANCY - Final approval on a project or final occupancy approval must be granted
by the Building Official prior to use or occupancy of the building or structure. Check the
job card for all required City inspections including final project approval and final
occupancy inspections.
5 - PLUMBING - Plumbing contractor license laws are regulated by Chapter 18.106 RCW.
Property owners who hire an unlicensed plumber may assume the risks and potential
monetary liability for work performed by unlicensed plumbing contractors. For more
information contact L&I Department of Licensing at 1-800-647-0982.
CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE
SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND ON EACH LEVEL IN
FOR
CARBON MONOXIDE SYSTEMS
NEW CONSTRUCTION AND IN EXISTING DWELLINGS WHEN ALTERATIONS, REPAIRS OR
INFORMATION
ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS
ARE ADDED OR CREATED.
It is the owner's responsibility to repair/replace all damage of utilities or frontage
DAMAGE TO FRONTAGE
FOR
improvements in City right of Ways or Easements to City Standards caused by or
IMPROVEMENTS
INFORMATION
occurring during the permitted project.
ELECTRICAL PERMIT
FOR
Obtain Electrical Permit from State Department of Labor and Industries 425-290-1309.
NFORMATION
FOR
MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD
ESC REQUIREMENTS
INFORMATION
REQUIREMENTS.
FOR
The engineering division requires 48 hours notice prior to the date of the FINAL
FINAL INSPECTION SCHEDULING
INFORMATION
Inspection.
Approval of this foundation design is conditional subject to inspection of existing site soil
FOR
conditions. Retaining walls must be designed and constructed to resist the lateral
FOUNDATION BEARING
INFORMATION
pressure of the retained material. Provisions must be made for the control and drainage
of surface water around buildings.
FOR
SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT.
INSPECTIONS
INFORMATION
www.mybuildingpermit.com
LOT LINES STAKED
FOR
Lot line stakes must be in place at the time of foundation setback inspection.
NFORMATION
LOT LINES STAKED
FOR
Lot line stakes must be in place at the time of foundation setback inspection.
NFORMATION
Maximum Height 25 feet. The agent or contractor shall set up the equipment; establish
the datum point and the point of average grade. Call for inspections to verify. These
MAXIMUM HEIGHT
O
items must be consistent with the approved plan. If the proposed height of a building is
INFORMATION
within 12 inches of the maximum height permitted for the zone an elevation survey is
required.
Printed: Monday, October 21, 2024 1:16:09 PM 2 of 3
'RESIDENTIAL
BLDG Permit
PERMIT NUM
of Edmonds
EdmondsCity
98020 1 C •
www.edmondswa.gov•
FOR
Heat pumps, AC units and similar equipment greater than 36 inches in height are not
SIDE YARD EQUIPMENT
INFORMATION
allowed within required building setbacks.
Sound or noise originating from temporary construction sites as a result of construction
activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of
FOR
7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding
SOUND AND NOISE
INFORMATION
Sundays and Federal Holidays. At all other times the noise originating from construction
sites and activities must comply with the noise limits of Chapter 5.30, unless a variance
has been granted pursuant to ECC 5.30.120.
Sound or noise originating from temporary construction sites as a result of construction
activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of
FOR
7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding
SOUND AND NOISE
INFORMATION
Sundays and Federal Holidays. At all other times the noise originating from construction
sites and activities must comply with the noise limits of Chapter 5.30, unless a variance
has been granted pursuant to ECC 5.30.120.
FOR
All utilities shall be located prior to any excavation. New locates shall be called for if at
UTILITY LOCATES
INFORMATION
time of excavation, original locates are no longer identifiable.
Installer shall provide the manufacturer installation, operating instructions, and a whole
WHOLE HOUSE FAN
FOR
house ventilation system operation description. A label shall be affixed to the whole
INFORMATION
house timer control that reads "Whole house ventilation, see operating instructions".
INSPECTIONS
- Schedule Online
at https://inspection.mybuildingpermit.com
INSPECTIONTYPE INSPECTOR
COMPLETED
RESULT
NOTES
A-1 BUILDING PRECON
B-1 SETBACKS
B-2 FOOTINGS
B-2 FOUNDATION WALL
B-2 ROOF TEAR OFF
B-3 EXT WALL SHEATHING
B-3 MECH ROUGH IN
B-3 ROOF SHEATHING
B-3 UNDERFLR FRAMING
B-4 DRYWALL FASTENING
B-4 FRAMING
B-4 INTERIOR SHEAR
B-5 INSULATION ENERGY
B-7 BUILDING OTHER INSP
X-3 BUILDING FINAL"
A-1 TESC AND MOBILIZE
E-3 STRM TIGHTLINE
E-9 COMPOST AMEND
X-2 ENGINEERING FINAL
Printed: Monday, October 21, 2024 1:16:09 PM 3 of 3