APPROVED ENG2024-0174 ROW PERMITRIGHT OF WAY EUC PERMIT
PERMIT NUMBER
City of Edmonds
- N, Edmonds WA •:0i i
www.edmondswa.govi
Description: PUD-REPLACE 2 BO POLES AND INSTALL TRANSFORMER
ISSUED: 10/25/2024
Address: 8517 186TH ST SW EDMONDS WA 98026-5733
EXPIRES: 04/25/2025
rmit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 00567800001000
i
NAME TYPE NAME ADDRESS PHONE
APPLICANT MOE MATTHEWS PO BOX 1107, EVERETT WA 98206 (425)783-5681
CONTACT SNOHOMISH COUNTY PUD PO BOX 1107, EVERETT WA 98206 (425)870-9753
CONTRACTOR SNOHOMISH COUNTY PUD PO BOX 1107, EVERETT WA 98206 (425)783-4353
OWNER DIANE F & KEVIN D MOONEY 8517 186TH ST SW, EDMONDS WA 98026-5733
FEE INFORMATION
DESCRIPTION AMOUNT PAID
CITY TECHNOLOGY FEE - PER PERMIT
$45.00 $45.00
ENG - INSPECTIONS - 4.1.24
$264.00 $264.00
ROW - STANDARD - 4.1.24 $396.00 $396.00
REQUIREMENTS
REQUIREMENT TYPE NOTES
TRAFFIC CONTROL
Traffic control and public safety shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification
verifying completion of the required training in their posession.
RESTORATION
Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with
asphalt or City approved material prior to the end of the workday - No Exceptions
WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final
inspection and acceptance of the work.
INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM
24 HR NOTICE REQUIRED
The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of
any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its
departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney
fees by reason of granting this permit.
RELEASED BY: MAJ DATE: 10/25/2024
Printed: Friday, October 25, 2024 3:04:53 PM 1 of 2
RIGHT OF WAY EUC PERMIT
PERMIT NUM11BE
City of Edmonds
....121
Sth Ave N, Edmonds WA •:0
www.edmondswa.gov • •
CONDITIONS
CONDITION TYPE
ALERT RESIDENTS
ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START.
It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in
DAMAGE TO FRONTAGE
City right of Ways or Easements to City Standards caused by or occurring during the permitted
IMPROVEMENTS
project.
MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD
ESC REQUIREMENTS
REQUIREMENTS.
Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to
indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and
agents from any and all claims for damages of whatever nature, arising directly or indirectly from the
HOLD HARMLESS
issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any
requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance
provision.
SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT.
INSPECTIONS
www.mybuildingpermit.com
POTHOLING
VERIFY CLEAR BORE CROSSINGS.
RESTORE LANDSCAPE
Restore landscape to like or better conditions
Sound or noise originating from temporary construction sites as a result of construction activity are
exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on
SOUND AND NOISE
weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all
other times the noise originating from construction sites and activities must comply with the noise
limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
All utilities shall be located prior to any excavation. New locates shall be called for if at time of
UTILITY LOCATES
excavation, original locates are no longer identifiable.
INSPECTIONS
INSPECTION TYPE
DATE
RESULT
COMPLETE
A-1 JOB START
X-2 ENGINEERING FINAL**
E-7 RESTOR LIMITS
E-7 CONCRETE SIDEWALK
Printed: Friday, October 25, 2024 3:04:53 PM 2 of 2
RECEIVED
of EpM04O�
SECTION A
RIGHT OF WAY CONSTRUCTION
PERMIT APPLICATION
Complete and submit this Application in accordance with the Submittal
Requirements outlined in Right-of-Wgy permit Handout E6�.
Apr 19 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
If any field is not applicable to your project, write "N/A' instead of leaving blank.
All fields required. Incomplete Applications will be denied.
General •
Project Name BO Pole Replacements - PLI 9011, 9004 (WO# 100130186)
Site Address or if no site address use Property Address at NW corner of project area: 85 17 186TH ST SW
Associated Permits: BLD PLN ENG
Owner and Entity Holding
Name of Company SNOHOMISH COUNTY PUD NO.1 Franchise Ordinance No: N/A
Point of Contact KENNETH LUU
Title DESIGNER
Address 21014 63RD AVE W
City LYNNWOOD
State WA
Zip 98036
Phone 425-670-3214
Email KCLUU@SNOPUD.COM & permits@snopud.com
Contractor and Authorized Agent of Owner
Name of Company SAME AS ABOVE
(see note below)
Contractor Contacts During Construction
Primary Name SAME AS ABOVE
Agent Name
Title
Title
Mobile
Address
Email
City State
Zip
Secondary Name
Phone
Title
Email
Mobile
City of Edmonds Business License No: N/A
Email
State License No: 3 1 3-005-74 1
Contractor verifies it is currently bonded
® Contractor verifies it currently has general liability insurance
NOTE: ECDC 18.6o. o2o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city
engineer.
❑ Multifamily residential ❑ Commercial ❑ City project
❑ Single family residential subdivision ❑ Single family -other ❑ Industrial
❑ Demo and rebuild or from vacant land?
❑ Other, please specify:
In Utility Franchise Work associated with development (check one of the above boxes as welt
❑ Traffic Control Only (no associated development)
❑ Utility Franchise Work (no associated development)
City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021
Include an overall narrative description of the proposed work. Be specific and detailed:
Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc.
Include whether this is construction, maintenance, or repair.
Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for
underground utilities, etc.)
Replace 2 total poles at SW corner of 8517 186th St SW (PLI 9011) and SE corner of 8615 187th PI SW (PLI 9004). Transfer primary and neutral lines and streetlights onto new
poles. Replace transformer and install (1) secondary riser on PLI 9004; tie riser to existing conduit feeding SW corner of 8608 185th PI SW. 50' section of westbound lane of 186th
St SW and 187th PI SW to be closed for 8 hours total between the hours of 8:OOAM - 4:00PM. Includes tree trimming at PLI 9004 and along north side of 187th PI SW. Ground
disturbance in soft surface only.
RIGHT-OF-WAY
CLOSURE
AREA
TOTAL
DURATION
(Number of Months)
Sidewalk 72 hours +
LF
I x
LF
SF
N/A
Alley'72 hours +
LF
Ix
I LF
SF
N/A
Parking 72 hours +
LF
I x
I LF
SF
N/A
SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C.
1. The work in the right of way is on or for the following type of facilities:
❑ telecommunications ❑ cable e power ❑ gas
❑ water ❑ sewer ❑ storm
Details of Work to be Completed
1. Does the utility owner have existing overhead infrastructure in the area of work?
Yes
X
No
2. Will any equipment be added underground or above ground (e.. pedestals, vaults, etc.)?
X
If yes, describe: pnl mQ
3.
Does the proposed work connect a lot or commercial development with utilities that serve more
than one lot or commercial development?
X
4.
Does the work involve rebuilding or relocating an existing aboveground utility system which
connects a lot or commercial development to an existing underground common utility stem?
X
5.
Does the work involve proposed additions to an aboveground utility stem? If es:
X
Are the additions for the purpose of serving new commercial development?
Are the additions for the purpose of serving a single-family residential subdivision?
Details
of Work to be Completed
Yes
No
6.
Does your project involve rebuilding or replacing utility equipment which currently serves more
than one lot or commercial development?
If yes, answer the following questions related to project area, i.e. the actual area in which the
X
project is proposed:
6a.
Does your project involve wires/cables/lines? If yes:
X
How many are existing? 12 1 How many are to be added? 1 0
City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021
6b.
Does your project involve poles? If yes:
X
How many poles are existing in the project area? 2
What is the height of the existing poles? 45'
How many poles are to be removed? o
Are additional poles to be laced? No
How many? I I What is the height of the additionalpoles?
6c.
Are any poles to be modified/rebuilt/replaced? If yes:
X
How many? 12 1 What is the height of the poles after? All 45'
Describe the modification rebuild: Pole replacement adjacent to existing location
SECTION C
Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as
required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have
certification verifying completion of the required training in their possession.
Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be
patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS.
Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to
any permit approval.
Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials,
officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever,
foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or
omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose
acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and
specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any
respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the
expiration, revocation, or termination of any resulting permit approval.
Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and
requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to
the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal
Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable
requirements of state and federal law.
Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a
licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by
owner to act on its behalf and have authority to bind the owner to this application.
Fees. The Applicant is responsible for all permit fees.
APPLICANT SIGNATURE: Kenneth Luu �a 202aU17161544-0TW DATE: 4i17/2024
APPLICANT PRINTED NAME: Kenneth Luu
APPLICANT TITLE: Engineering Tech 2
NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE
City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021
SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM
so�oMs�<o��,• OWNER/CONTRACTOR IS RESPONSIBLE FOR
PUBLIC UTILITY DISTRICT NO.1 OF SNOHOMISH COUNTY EROSION CONTROL AND DRAINAGE
LOCATION 8517 186TH ST SW & 8615 187TH PL SW LYNNWOODAREA
POLE NO. 9011 & 9004 NW1/4S 18 T 27 R 4 DATE 04/11/2024 ORDER 100130186
REASON FOR WORK PUD MAINTENANCE ENGINEER K. LUILI OPERATION 0030
BO POLES - PLI 9011 & 9004 DRAFTER U.G. NO.
SCALE 1" = 50=
APPROVED
& DATE PRINTED
DATE WORK COMPLETED
FOREMAN
FEES REQ'D El YES ■NO
PRIMARY OVERHEAD
❑ RESIDENTIAL
❑ COMMERCIAL
LEO NO.
@$ '=$
SECONDARY OVERHEAD
NESC VIOLATIONS
BASIC FEE E
■ NO ❑ YES (SEE NOTES)
@$ 1=$
PERMITS (DATE GRANTED)
❑ TREE TRIM
El STATE
METER/CONV. POLE 96
PRIMARY UNDERGROUND
❑ RESIDENTIAL
❑ COUNTY
❑ COMMERCIAL
■ CITY
BASIC FEE 3
❑
EASEMENTS
LEU NO.
@$ _$
■ REQUIRED ❑ NOT REQUIRED
E-64095
SECONDARY UNDERGROUND
BASIC FEE S
DATE RELEASED
@$ _$
UNDERGROUND PLAT
FOREIGN CONTACTS
■ JPN# 100130186
BASIC FEE S
q FT.@$ _$
❑ JOINT TRENCH ZIPLY & CATV
❑ JOINT BORE ZIPLY & CATV
STREET LIGHTING
❑
POLE STENCILING
WORK IN RIGHT OF WAY
FROM TO
❑ PRIMARY
TAKE OFF POLE
❑ SECONDARY
PRE—CONST. REQUIRMENTS
■ TREE TRIM ❑ PUD LOCATOR
q FT.@$ '=$
MISCELLANEOUS FEES
❑ BACKHOE ■ FLAGGING
VAULT
ONE CALL DATE 04/17/24
PERMIT S
No. MULTIPLE
STREET LIGHTING
$
$
■ YES ❑ NO
$
M&R
AS -BUILT
GIS
TOTAL DUE � N/
DATE PAID N/A
GIS OC
M&R
GIS Ph
JOINT USE
RECEIPT NO.
LOCATION MAP PAGE 454 J3
SERVICE ORDER NO.
LEGEND: i nr: TPKT#
24142499 - PLI 9011
O EXISTING POLE 24142510 - PLI 9004
X EXISTING POLE -TO BE REMOVED
• NEW POLE
NEW POLE TO REPLACE EXISTING POLE
DATE
SUBSTATION PRV
CIRCUIT NO. 12-93 PHASE 1 & 3
ENGR'S TEL. #
425-670-3214
ENGR'S CELL #
425-870-9753
TRANSFER OF UTILITIES, REMOVAL OF POLE AND FINAL RESTORATION TO BE CONSISTENT
WITH APPLICABLE POLE ATTACHMENT AGREEMENT(S) AND JOINT OWNERSHIP POLE AGREEMENT.
RECEIVED
SET 45' CL2 POLE 7' NE AT DEPTH OF 6.5' (PW2045) OCT 11 2024
FRAME POLE AS 7.2KV 1PH VERT TANGENT ANGLE PER 12V102
INSTL SIDEWALK GUY W/ 8' AHR, L=5' W (GO107) CITY OFEDMONDS
DEVELOPMENT
XFR EXISTING OH PRI & NEUT, AND SL-129736-A; SERVICES DEPARTMENT
INSTL NEW 10' SL ARM (1-0504)
- PUD TO ENFORCE POLE ATTACHMENT O
AGREEMENT.
- PUD IS RESPONSIBLE FOR ENSURING THAT THE
N OLD POLES ARE REMOVED.
PL 1 9004
NEW 50KVA XFMR
A-)
SCHEMATIC
NTS
SET 45'CL2 POLE 4'S AT DEPTH 0
6.5' (PW2045)
FRAME POLE AS 7.2KV 1PH VERT D
PER 12V102
INSTL 1PH SEC RISER TO EXISTIN(
OU705, NO V0101 & T1522); REROUI
EXISTING 350KCM TO NEW RISER
INSTL NEW 3/8'' SIDEWALK GUY
8' AHR, L=6' E (GO107, A0101)
RMV 75 KVA OH XFMR
UTC #75-1925
SER#
HANG NEW 37.5 KVA OH XFMR
(BA21P, 121`601)
UTC# -----------------
SER# -----------------
XFR EXISTING OH PRI & NEUT,
AND SL-129736-A; INSTL 8'
SL ARM (1-0503)
(45', CL1, 1970); RMV DG & AHR
y �
8618 8610
RESTORATION LIMITS TO BE DETERMINED
BY CITY ENGINEERING INSPECTOR
SL-1297316-A
WORK AREA
PuGu
sou ND A
VICINITY MAP
VEGi TRIM BRANCHES WITHIN 10' OF
OH PRI& NEUT
10
517
186TH S11 SVW
_--- 33952
Q) 25-25519
01
aNi
0
a
0
m
0
0
rn
0
OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING
ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY
UTILITIES MAY REQUIRE A SEPERATE PERMIT.
8520
8510 °
0
a
a
Q0
VEG: TRIM TREE WITHIN 3' OF �M
NEW & EXISTING POLE
�N
ENGINEERING DIVISION
Applicant shall repair/replace all APPROVED AS NOTED
damage to utilities or frontage
improvements in City right-of-way
per city standards that is caused or Jill 10/25/2024
occurs during the permitted project. —VV
LANE CLOSURE ON A TWO-LANE ROAD
(TWO FLAGGER OPERATION)
ROAD
W20-1 WORK
AHEAD
x
ONE LANE
W20-4 ROAD
AHEAD
x
W20-7A •�
x
Z Q
00
00
N M
(U)
F—
(n
r
O
x
G 2 0 - 2 ROADNWORK =
48" x 24"
(OPTIONAL)
RECEIVED
Apr 19 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
❑•
•❑
48" x 24'
i ROADNWORK G 2 0- 2
x (OPTIONAL)
0
0
PLI 9011
ml
N
NORTH
I
SIGN SPACING
= X
FREEWAYS & EXPRESSWAYS
55-70
MPH
1500'±
RURAL HIGHWAYS
60-65
MPH
800'±
RURAL ROADS
45-55
MPH
500'±
RURAL ROADS & URBAN ARTERIALS
35-40
MPH
350'±
RURAL ROADS & URBAN ARTERIALS
RESIDENTIAL & BUSINESS DISTRICTS
25-30
MPH
200'± (2)
URBAN STREETS
1 25 MPH OR LESS
I 100'± (2)
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE
RAMPS, AT -GRADE INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
zQ
LoO
x
•� W20-7A
x�',
ONE LANE
i ROAD W 2 0- 4
AHEAD
x
ROAD
i WORK W20-1
AHEAD
ENGINEERING DIVISION
APPROVED AS NOTED
,%,Pi/ (,Vb,10,,44z 10/25/2024
vv
W20-78
BE
PREPARED
TO STOP
OPTIONAL IF
40 MPH OR LESS
THIS PLAN MAY BE MIRRORED FOR
OPPOSITE SIDE OF ROADWAY USING
SAME SIGNS AND SPACING.
YES ❑ NO ❑ INITIAL
GENERAL NOTES:
1. ALL SIGNS AND SPACING SHALL CONFORM TO THE MUTCD.
2. NOTIFY LOCAL EMERGENCY SERVICES OF CLOSURE TIMES AND
DATES (OPTIONAL).
3. SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROAD
CONDITIONS.
4. PROTECTIVE VEHICLE RECOMMENDED -MAY BE A WORK TRUCK.
5. ALL SIGNS MINIMUM 48" X 48", UNLESS OTHERWISE SPECIFIED.
6. CHANNELIZATION DEVICES ARE 28" REFLECTIVE CONES. SEE TABLE 1
FOR SPACING DISTANCES.
7. ALL SPACING MAY BE ADJUSTED TO ACCOMODATE AT -GRADE
INTERSECTIONS AND/OR DRIVEWAYS.
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
25
30
35
40
45
50
55
60
65
70
LENGTH (FEET)
155
200
250
305
360
425
495
570
645
730
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT
9,900 TO 22,000 LBS.
HOST VEHICLE WEIGHT
> 22,000 LBS.
< 45 MPH
45-55 MPHJ
> 55 MPH
< 45 MPH
45-55 MPH
> 55 MPH
100' 1
123'
172'
74'
100'
150'
TABLE 1
CHANNELIZATION DEVICE
SPACING (FEET)
MPH
TAPER
TANGENT
50-65
10 TO 20
80
35-45
10 TO 20
60
25-30
1 10 TO 20
40
rwardamimlov
O
CHANNELIZING DEVICE
r
FLAGGING STATION
=
PORTABLE SIGN AND SUPPORT
�®
WORK VEHICLE WITH FLASHING
LIGHT
WORK AREA
E61011
r o •
m
GENERAL NOTES:
1. ALL SIGNS AND SPACING SHALL CONFORM TO THE MUTCD.
2. NOTIFY LOCAL EMERGENCY SERVICES OF CLOSURE TIMES AND
DATES (OPTIONAL).
3. SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROAD
N CONDITIONS.
NORTH 4. PROTECTIVE VEHICLE RECOMMENDED -MAY BE A WORK TRUCK.
5. ALL SIGNS MINIMUM 48" X 48", UNLESS OTHERWISE SPECIFIED.
6. CHANNELIZATION DEVICES ARE 28" REFLECTIVE CONES. SEE TABLE 1
FOR SPACING DISTANCES.
7. ALL SPACING MAY BE ADJUSTED TO ACCOMODATE AT -GRADE
INTERSECTIONS AND/OR DRIVEWAYS.
SIGN SPACING
= X
FREEWAYS & EXPRESSWAYS
55-70
MPH
1500'±
RURAL HIGHWAYS
60-65
MPH
800'±
RURAL ROADS
45-55
MPH
500'±
RURAL ROADS & URBAN ARTERIALS
35-40
MPH
350'±
RURAL ROADS & URBAN ARTERIALS
RESIDENTIAL & BUSINESS DISTRICTS
25-30
MPH
200'± (2)
URBAN STREETS
25 MPH OR LESS
100'± (2)
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE
RAMPS, AT -GRADE INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
Ism,"yRsZ
8628 `
8614
TABLE 1
O
CHANNELIZING DEVICE
CHANNELIZATION DEVICE
r
FLAGGING STATION
SPACING (FEET)
PORTABLE SIGN AND SUPPORT
MPH
TAPER
TANGENT
�®
WORK VEHICLE WITH FLASHING
50-65
10 TO 20
80
LIGHT
35-45
10 TO 20
60
25-30
10 TO 20
40
WORK AREA
RECEIVED
Apr 19 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
ENGINEERING DIVISION
APPROVED AS NOTED
jdl 10/25/2024
RECEIVED
Apr 19 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES CITY OF EDMONDS MyBuildingPermit.com
DEPARTMENT
Right -of -Way Application #1475481 - WO 100130186
Applicant
First Name Last Name Company Name
Moe Matthews Snohomish County PUD
Number Street Apartment or Suite Number E-mail Address
PO Box 1107 permits@snopud.com
City State Zip Phone Number Extension
Everett WA 98206 (425) 783-5681
Contractor
Company Name
Owner
Number Street Apartment or Suite Number
City State Zip Phone Number Extension
State License Number License Expiration Date UBI # E-mail Address
Project Location
Number Street Floor Number Suite or Room Number
8517 186TH ST SW
City Zip Code County Parcel Number
EDMONDS 98026 00567800001000
Associated Building Permit Number Tenant Name
Additional Information (i.e. equipment location or special instructions)_
Work Location
Property Owner
First Name Last Name or Company Name
Diane F & Kevin D Mooney
Number Street Apartment or Suite Number
8517 186TH ST SW
City State Zip
EDMONDS WA 98026-5733
Certification Statement - The applicant states:
I certify that I am the owner of this property or the owner's authorized agent. If acting as an authorized agent, I further certify that I have full power and
authority to file this application and to perform, on behalf of the owner, all acts required to enable the jurisdiction to process and review such application. I
have furnished true and correct information. I will comply with all provisions of law and ordinance governing this type of application. If the scope of work
requires a licensed contractor to perform the work, the information will be provided prior to permit issuance.
Date Submitted: 4/18/2024 Submitted By: Moe Matthews
Page 1 of 2
i
CITY OF EDMONDS MyBuildingPermit.com
Right -of -Way Application #1475481 - WO 100130186
Project Contact
Company Name: Snohomish County PUD
Name: Kenneth Luu Email: kcluu@snopud.com
Address: PO Box 1107 Phone #: (425) 870-9753
Everett WA 98206
Project Type
Utility Purveyor
Project Name: WO 100130186
Activity Type
Utility Work
Scope of Work
Disturbance of Surface
WO 100130186: Replace 2 total poles at SW corner of 8517 186th St SW (PLI 9011) and SE
corner of 8615 187th PI SW (PLI 9004). Transfer primary and neutral lines and streetlights onto
Description of new poles. Replace transformer and install (1) secondary riser on PLI 9004; tie riser to existing
Work: conduit feeding SW corner of 8608 185th PI SW. 50' section of westbound lane of 186th St SW
and 187th PI SW to be closed for 8 hours total between the hours of 8:00AM - 4:00PM. Includes
tree trimming at PLI 9004 and along north side of 187th PI SW. Ground disturbance in soft
surface only.
Project Details
Project Information
Job Number
WO 100130186
Page 2 of 2