Loading...
BLD2024-1413_Manufacturer_Specifications_and_Installation_Instructions_10.28.2024_8.14.26_AM_4583884FE4A, FESA EVOLUTION@ SERIES COMMUNICATING VARIABLE -SPEED FAN COIL bryant PURON® REFRIGERANT SIZES 002 THRU 006 bryant Product Data PREMIUM ENVIRONMENTALLY -SOUND FAN COIL The latest in technology makes the FE4A and FESA fan coil models the most advanced air handlers available. With attention to quiet, efficient, and comfortable operation, Bryant has developed a new benchmark for homeowner comfort and ease of installation. The FE4A and FESA utilize the Evolution® Control as a required accessory to enable state of the art smart -diagnostics capability. This enables faster troubleshooting, providing ease of service and repair. The FE4A and FESA also provide a 4-wire hook up with matching outdoor unit and the EvolutionO Control. This makes installation simpler and a lot quicker than with conventional fan coils. The FE4A and FESA have advanced technology that allows the fan coil to self -configure with a matching outdoor unit and the Evolution'5 Control, cutting down on installation time. The FE4A and FESA feature Puron@ refrigerant, the chlorine -free alternate that is the future for the residential heating and cooling industry. The FE4A and FESA using Puron® refrigerant maximize performance for environmentally sound systems. In addition to environmental safety, these systems are 30 to 40% more efficient than standard heating and cooling systems, thereby combining excellence in efficiency and environmental safety. The FE4A and FESA provide these benefits due to Bryant's command of Electronically Commutating Motor (ECM) technology. These motors are extremely efficient at all speeds, and enable the FE4A and FESA to operate at the correct speed to deliver airflow precisely, ensuring proper performance across a wide range of duct static pressures. This adaptive efficiency also makes installation quality easier to achieve for today's demanding homeowner. Bryant's command of ECM technology may be most evident in the comfort advantages that an ECM can deliver. For true comfort, the homeowner can achieve command of both temperature and humidity in cooling and heating modes. Another feature which sets the FE4A and FESA apart is the factory -installed TXV, which enhances efficiency and provides compressor -protecting operation at all recommended conditions. Grooved tubing, louvered aluminum fins, and the large face areas of the FE4A and FESA refrigerant coils also provide superior efficiency, for high SEER and HSPF performance. Bryant leads the way in condensate control, a hallmark of these multipoise fan coils. All of these featured components are protected within a rugged, pre -painted metal cabinet lined with super -thick, high -density insulation. For neat, high quality installations, the unit exterior features sweat refrigerant connections for simple leak free performance, and multiple electrical entry for both high and low voltage service. For superior technology and unmatched comfort, the environmentally sound and efficient FE4A and FESA fan coils can't be beat. FEATURES Smart Diagnostics • Self configuring (ease of installation) • Easier troubleshooting, providing faster service and repair Environmentally -Sound Refrigerant Technology • Puron® refrigerant the chlorine -free, non -ozone depleting refrigerant • Thermostatic Expansion Valve (TXV) designed to maximize performance with Puron® refrigerant Energy Efficient Operation • Electronically Commutated Motor (ECM) operates efficiently at all speeds • Maximizes efficiency of heating and cooling systems • Ultra -low power consumption during fan only operation Comfort Control • Warm, comfortable heating air temperatures • Unmatched humidity control Airflow and Sound Technology • Logarithmic spiral blower housings for high blower efficiency and quiet operation • Diffuser air discharge section for high airflow efficiency and quiet, smooth operation • High duct static capability • Unique cabinet design that meets new stringent regulations for air leakage. Meets requirements of a 2% cabinet leakage rate when tested at 1.0 in we of static pressure. Condensate Control and Disposal Technology • Minimal standing water - less microbial growth for improved IAO and reduced condensate line clogging and related condensate leakage • Condensate fittings relocated away from turbulent airflow patterns at the blower entrance for improved condensate control performance • Overflow feature for slope coil units allows condensate to exit the unit without damage to product under clogged primary and secondary line conditions • Tested for condensate disposal at conditions much more severe than those required by ARI • Primary and secondary drain connections to comply with HUD • All pans constructed of an injection molded glass -filled polycarbonate engineered resin material, with brass drain connections • High density, super thick cabinetry insulation with vapor barrier • Pre -painted galvanized sheet metal cabinet Heat Transfer Technology • Grooved tubing • Lanced sine wave aluminum fins • Discreet refined counterflow refrigerant circuitry • Bi-flow hard -shutoff TXV metering device Quality Assisting, Ease of Installation and Service Features • Easy 4 wire hook up: convenient and reduces installation time. • FE4A unit is multipoise • FE5A unit is upflow/downflow only (single drain pan). • Provision made for suspending from roof or ceiling joints • Modular cabinet on sizes 003 through 006 • Sweat connections for leak free service • Multiple electrical entry for application flexibility (high and low voltage) • Low voltage terminal strip, to safely hold connections within the cabinet • Cabinet construction features innovations designed to prevent cabinet sweating Controls and Electrical Features • Easy plug connection provided for quick installation of accessory heater packages • 40VA 208/230v transformer • Replaceable 3-amp blade -type auto fuse protects against transformer secondary short Filter Features • Factory supplied filter • Cleanable polyester filter media • Filter "springs" out for easy access - no tools required • Newly improved filter rack area - filter door insulation added for an improved air seal MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 F E 4 A N B 0 0 2 0 0 0 Product F = Fan Coil Type E = Evolution®, VS, Puron@ Refrigerant Position 4 = Multi —poise 5 = Upflow / Downflow Series A Electrical N = 208/230v, 1ph-60 Hz Pti�r6n_ the environmentally sound refrigerant Capacity 002 = 18-36,000 003 = 24-42,000 004 = 24-42,000 005 = 30-48,000 006 = 36-60,000 Cabinet / Insulation B = Modular F = Single piece IMM IFJ TM Mark indicates a ufacturer's participation in the program For verification of certification for individual prodduccts, go to hridiremory.org. IS0 9001 GMIS Global wi Coil Type T00 = Tin—plated 000 = Copper L00 = Aluminum 3 am m IUY VILW INLET AIR FRONT VIEW SHOWN WITH "A" COIL DETAILS CONNECTION IOCATIONS FOR UPFIOW OR HQR11. APRI If.ATIONS DIMENSIONS IA. N.O. OW VOLTAGE OL WIRING NOTE: I. SERIES DESIGNATION IS THE 14TH POSITION OF UNIT PRODUCT NUMBER IN n 2 1/8" NOTE: ALLOW 21'CE FROM FRONT 22 1/16' ID 3/I6" II' 1OUTLET AIR 718" 3/4' FOR SERVI ALTERNATE UNIT CONNECTION SIZES SUCTION: 002 d 003 - 3/4" I. D. SWEAT ALTERNATE 1/8" 3/32" 2"DIA. M.O.'S FOR HIGH VOLTAGE POWER WIRING NOTE: MODULAR UNITS WILL HAVE pp4 - 006 D. SWEAT 7/g"DIA. M.O. OPPOSITE SIDE A TWO-PIECE LIQUID: 3/8' I D. SWEAT FOR LOW VOLTAGE CONDENSATE. 3/4' FEE CONTROL WIRING CABINET OPTIONAL FIELD CONVERTED INLET AIR SIDE RI SHE NO R (SLOPE COIL UNIT TS ONLY) A � I I/2" SLOPE COIL DETAILS CONNECTION LOCATIONS SHOWN EON UPELOW OR E. , LEFT APPLICATIONS ACCESS PANEL CONFIG. FOR 1 114" SLOPE COILS DOWNFLOW OR HORIZ. RIGHT APPLICATIONS AND A" COILS DOWNFLOW APPLICATIONS o MA H FOR 19' MODULAR UNITS OPENING 1O 13/I6" 2 I/2° RIGHT SIDE VIEW INLET AIA A B C D E H* UNIT SIZE in mm in mm in mm in . mm in mm in mm FE4A 002 42-11/16 1084 17-5/8 448 15-3/4 400 15-5/8 397 10-3/4 273 — — FE4A 003 53-7/16 1357 21-1/8 537 19-1/4 489 19-1/8 486 19-3/16 487 FE4A 003* 53-7/16 1357 21-1/8 537 19-1/4 489 19-1/8 486 19-3/16 487 28-5/16 719 FE4A 005 53-7/16 1357 21-1/8 537 19-1/4 489 19-1/8 486 19-1/2 495 FE4A 005* 53-7/16 1357 21-1/8 537 19-1/4 489 19-1/8 486 19-1/2 495 28-5/16 719 FE4A 006* 59-3/16 1503 24-11/16 627 22-3/4 578 22-11/16 576 25-1/4 641 34-1/16 865 FE5A 004* 59-3/16 1503 24-11/16 627 22-3/4 578 22-11/16 576 25-1/4 641 34-1/16 865 F moawar uaDinei NOTES: I. CONDENSATE PAN DRAIN CAPS NOT SHOWN FOR CLARITY. ® El O T" 7/8" TYP.+ HORIZ. LEFT (AS SHIPPED) /I6" TYP. AIRFLOW f2 PLAC ES I» © I' TYP. PRIMARY DRAI 12 PLACES)» A R 0'b —1 3/16" TYP. PLACES)» SECONDARY DRAIN PRIMARY DR! I/4" SECONDARY DRAI TYP.» TYP.+ SECONDARY DRAIN ® PRIMARY DRAIN L �2 7/8" 16" El T5/ YP Fj Il4" " TYP . Id/PLACES), PL AC E51+ 2 3/I6" 3 I/4" I )TYP TYP. DOWNFLOW (2 PLACES); UPFLOW (FIELD CONVERTED) (AS SHIPPED) + HORIZONTAL MOUNT LOCATIONS - DIMPLES PROVIDED IN TOP PANEL, AND NA CM OE CABINET IN CAP INET BOTTOM. HOLES PROVIDED .136" DIA. HORIZONTAL HANGING HARDWARE TO BE FIELD SUPPLIED. SECONDARY PRIMARY DRAI PRIMARY DRAI I 13/16" SECONDARY DRAIN TYP» © e oo f 12" TYP» 11 3/165 718" TYP' 7l8" " 2 TYP+ l T/8' TYP. (2 PLACES)- HORIZ. LEFT (AS SHIPPED) DIMENSIONS TYP. ACES) AIRFLOW /16" TYP 12 PLACES)» TYP PLACES) J F d 3/4' — 3 I/I6" O • I PRIMARY DRAIN r 1/8 I6' T/I6" TYP, 1 (4 PLACES)» DOWNFLOW UPFLOW (FIELD CONVERTED) (AS SHIPPED) A -COI I HORIZ. RIGHT (FIELD CONVERTED) —SECONDARY DRAIN PA IMAAY DRAIN TYP.B/16"» SECONDARY DRAIN — (z © Q O 1" TYP. 12 PLACES)» r I I/2' 1 T 5 7/8" 3/I6'/2"�• 7 1/8' TYP.+ 1 13/16' TYR' HORIZ. RIGHT TVPe. (FIELD CONVERTED) F G COIL CONFIGURATION SHIPPING WEIGHT UNIT SIZE in mm in mm Slope 'A' lb / kg FE4A 002 18-9/16 472 18-1/4 464 — Yes 135/61 FE4A 003 26-15/16 684 27-1/2 699 Yes — 150/68 FE4A 003* 26-15/16 684 27-1/2 699 Yes — 150/68 FE4A 005 27-1/4 692 26-15/16 684 — Yes 172 / 78 FE4A 005* 27-1/4 692 26-15/16 684 — Yes 172/78 FE4A 006* 32-15/16 837 32-5/8 829 — Yes 207 / 94 FE5A 004* 32-15/16 837 32-5/8 829 — Yes 200 / 91 F moawar uaDlneT PHYSICAL DATA NOMINAL DIMENSIONS SHIPPING ORDERING NO. FIELD -INSTALLED HEAT COOLING CA - WEIGHT Height Width Depth (kW) PACITY lb / kg (BTUH) FE4ANF002000 18,000 42-11/16-in10 17-5/8-in 448 22-1/16-in 135 lb FE4ANF002T00 5, 8, 9, 10, 15, 20 to 84 mm mm 560 mm 61 kg FE4ANF0021-00 36,000 FE4ANF003000 24,000 53-7/16-in 21-1/8-in537 22-1/16-in 150lb FE4AN(B,F)003T00 5, 8, 9, 10, 15, 18, 20 to 1357 mm mm 560 mm 68 kg FE4AN (B, F)003L00 42,000 FE4ANF005000 30,000 53-7/16-in 21-1/8-in537 22-1/16-in 172lb FE4AN(B,F)005T00 5, 8, 9, 10, 15, 18, 20, 24, 30 to 1357 mm mm 560 mm 78 kg FE4AN (B, F)005L00 48,000 FE4ANB006000 36,000 59-3/16-in 24-11/16-in 22-1/16-in 207lb FE4ANB006T00 8, 9, 10, 15, 18, 20, 24, 30 to 1503 mm 627 mm 560 mm 94 kg FE4AN B006L00 60,000 FE5ANB004T00 24,000 59-3/16-in 24-11/16-in 22-1/16-in 2001b FE5ANB004L00 5, 8, 9, 10, 15, 18, 20 to 42,000 1503 mm 627 mm 560 mm 91 kg SPECIFICATIONS MODEL SIZE co Refrigerant Metering Device 002 003 005 00. PuronO Refrigerant (R-410A) TXV 004 TXV Size 2 Ton 3 Ton 4 Ton 5 Ton 3 Ton Configuration A Slope A A A Rows-Fins/In. 3 / 14.5 Face Area (Sq Ft) 3.46 3.46 5.93 7.42 7.42 MATCHES OUTDOOR UNIT SIZES Nominal Cooling Tons 1.5, 2, 2.5, 3 2, 2.5, 3, 3.5 2.5, 3, 3.5, 4 3, 3.5, 4, 5 2, 2.5, 3, 3.5 FAN Air Discharge Upflow, Downflow, Horizontal Upflow, Downflow CFM/Ton (Nominal Clg/Htg) 350+ Motor HP (ECM) 1/2 1/2 1/2 3/4 3/4 Filter 21-1/2-in (546 mm) x ABINET CONFIGURATION OPTIONS 16-3/8-in (417 mm) W 1-piece 19-7/8-in (505 mm) I 1-piece/Modular 19-7/8-in (505 mm) 1-piece/Modular 23-5/16-in (592 mm) Modular 23-5/16-in (592 mm) - ml Modular PERFORMANCE DATA AIRFLOW DELIVERY - COOLING, HEATING, ELECTRIC HEATING MODES The FE4 and FE5A fan coils will provide airflow at a rate that is requested by the Integrated System User Interface during air conditioning or heat pump heating (without electric heat) modes. The nominal airflow for both heating and cooling modes is 350 cfm/ton nominal size of the outdoor unit installed. The airflow actually requested by the User Interface is modified by its internal algorithms for zoning, comfort or efficiency concerns. Refer to the documentation for the User Interface for more information on how the User Interface controls the fan coil. Safe operation of electric heaters requires airflow delivery at or above the minimum CFM for electric heater application listed in the chart below. The fan coil will adjust its airflow delivery to maintain safe airflow as operating mode and staging conditions require. FE4A/FE5A FAN COIL AIRFLOW DELIVERY CHART (CFM) - ELECTRIC HEATING MODELS ELECTRIC HEATER kW RANGE MODEL FE4A OUTDOOR UNIT CAPACITY BTUH 5 9 10 15 20 24 30 EMERGENCY 625 625 675 775 950 — — 18,000 625 625 675 — — — — 002 24,000 650 725 775 900 30,000 800 875 875 925 1125 36,000 975 975 975 1025 1125 EMERGENCY 675 700 775 850 1050 — — 24,000 675 875 875 1100 1150 — — 003 30,000 800 875 875 1100 1150 — — 36,000 975 975 1025 1150 1250 42,000 1125 1125 1125 1150 1350 EMERGENCY 675 700 775 850 1050 1400 1425 30,000 800 875 875 1100 1150 — — 005 36,000 975 975 1025 1150 1250 — — 42,000 1125 1125 1125 1150 1250 48,000 1305 1305 1305 1305 1350 1500 1600 EMERGENCY 1050 1050 1050 1050 1125 1750 1750 36,000 1050 1050 1100 1350 1350 — — 006 42,000 1125 1125 1150 1350 1350 — — 48,000 1300 1300 1300 1350 1500 1750 1750 60,000 1625 1625 1625 1625 1750 1750 1750 ELECTRIC HEATER kW RANGE MODEL FE5A OUTDOOR UNIT CAPACITY BTUH 5 9 10 15 20 24 30 EMERGENCY 675 775 775 900 1125 — — 24,000 975 975 975 — — — — 004 30,000 1050 1050 1100 1125 36,000 1050 1050 1100 1350 1350 42,000 1125 1125 1150 1350 1350 Note 1: Emergency — Air conditioner with electric heater application, or emergency heat. Note 2: These airflows are minimum airflows as UL listed. Note 3: Dashed entry indicates that the heater/fan coil/outdoor unit combination is not approved. Do not apply. ACCEPTABLE DUCT CONDITIONS 0.7 0.6 0.5 3 0.4 W [C Z) CO U W c[ d 0.3 U Q W J a oz a CO CO 0.1 ------------------------------------------------ - ------------ ACCEPTABLE RANGE TOO HIGH RETURN STATIC -------------------------�-------------�------------ --- PRESSURE ---- (DIFFICULT TO MAKE TRAP) ------------ -------------------------- ------------- -------------+------------- i ni nP na RETURN STATIC PRESSURE (in wc) A07273 For satisfactory operation (specifically making dry secondary trap), subject fan coils must be installed with duct systems which fall within the "Acceptable Range" illustrated above. MINIMUM RPM TABLE MAXIMUM STATIC TABLE MODEL SYSTEM SIZES CFM RANGE MIN RPM FE4ANF002 018, 024, 030, 036 150 — 1200 300 FE4AN(B,F)003 024, 030, 036, 042 200 — 1400 285 FE4AN(B,F)005 030, 036, 042, 048 250 — 1600 275 FE4ANB006 036, 042, 048, 060 500 — 2000 275 FE5ANB004 024, 030, 036, 042 500 — 1400 275 MODEL AIRFLOW DELIVERY AVAILABLE STATIC PRESSURE FE4ANF002 525 CFM 1.00 in we 700 CFM 1.00 in we 875 CFM 1.00 in we 1050 CFM 0.80 in we 1200 CFM 0.60 in we FE4AN(B,F)003 700 CFM 1.00 in we 875 CFM 1.00 in we 1050 CFM 1.00 in we 1225 CFM 1.00 in we 1400 CFM 0.80 in we FE4AN(B,F)005 875 CFM 1.00 in we 1050 CFM 1.00 in we 1225 CFM 1.00 in we 1400 CFM 1.00 in we 1600 CFM 0.50 in we FE4ANB006 1050 CFM 1.00 in we 1225 CFM 1.00 in we 1400 CFM 1.00 in we 1750 CFM 1.00 in we 2000 CFM 0.60 in we FE5ANB004 700 CFM 1.00 in we 875 CFM 1.00 in we 1050 CFM 1.00 in we 1225 CFM 1.00 in we 1400 CFM 1.00 in we GROSS COOLING CAPACITIES (MBTUH) INDOOR COIL SATURATED TEMPERATURE LEAVING EVAPORATOR (°F / °C) AIR 35/2 40/4 45/7 50/10 55/13 CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF 72/22 40.19 19.65 0.00 36.23 17.59 0.00 31.86 15.48 0.00 27.00 13.31 0.00 21.65 11.11 0.00 500 67/19 32.99 19.92 0.01 28.96 17.79 0.01 24.52 15.62 0.01 19.64 13.40 0.01 14.28 11.17 0.01 62/17 26.44 20.11 0.01 22.36 17.93 0.01 17.93 15.73 0.01 13.56 13.56 0.03 11.28 11.28 0.19 72/22 49.76 24.23 0.00 44.85 21.76 0.00 39.40 19.20 0.00 33.36 16.55 0.01 26.66 13.83 0.01 650 67/19 40.90 24.80 0.01 35.90 22.22 0.01 30.37 19.55 0.02 24.27 16.82 0.02 17.58 14.06 0.02 62/17 32.84 25.24 0.02 27.75 22.56 0.02 22.25 19.85 0.02 17.13 17.13 0.06 14.25 14.25 0.21 72/22 61.99 30.08 0.00 55.87 27.15 0.00 49.04 24.04 0.01 41.48 20.80 0.02 33.10 17.46 0.02 875 67/19 51.08 31.23 0.03 44.83 28.09 0.03 37.91 24.84 0.03 30.23 21.47 0.03 21.83 18.03 0.03 62/17 41.11 32.14 0.03 34.76 28.88 0.03 27.91 25.53 0.04 22.04 22.04 0.10 18.33 18.33 0.25 72/22 67.83 32.91 0.00 61.10 29.76 0.00 53.66 26.40 0.02 45.36 22.89 0.03 36.17 19.27 0.03 1000 67/19 55.96 34.39 0.04 49.12 31.01 0.04 41.53 27.48 0.04 33.11 23.83 0.04 23.88 20.06 0.04 62/17 45.09 35.62 0.04 38.13 32.08 0.04 30.69 28.43 0.05 24.54 24.54 0.12 20.40 20.40 0.27 72/22 77.77 37.84 0.00 70.13 34.30 0.03 61.59 30.55 0.05 52.04 26.60 0.05 41.42 22.50 0.05 1250 67/19 64.36 40.02 0.06 56.52 36.24 0.06 47.77 32.27 0.06 38.04 28.12 0.06 27.46 23.81 0.07 62/17 51.98 41.92 0.06 44.00 37.93 0.06 35.61 33.77 0.08 29.12 29.12 0.16 24.20 24.20 0.30 FE4ANF003 72/22 43.01 20.98 0.00 38.69 18.78 0.00 33.92 16.51 0.00 28.64 14.18 0.00 22.85 11.81 0.01 600 67/19 35.27 21.34 0.01 30.88 19.04 0.01 26.07 16.71 0.01 20.79 14.34 0.01 15.03 11.95 0.01 62/17 28.24 21.59 0.01 23.81 19.25 0.01 19.05 16.90 0.02 14.56 14.56 0.05 12.11 12.11 0.21 72/22 53.83 26.15 0.00 48.40 23.49 0.00 42.36 20.71 0.00 35.72 17.83 0.02 28.38 14.89 0.02 800 67/19 44.23 26.92 0.02 38.71 24.10 0.02 32.61 21.20 0.03 25.91 18.24 0.03 18.65 15.26 0.03 62/17 35.47 27.49 0.03 29.87 24.58 0.03 23.89 21.65 0.03 18.67 18.67 0.09 15.51 15.51 0.24 72/22 63.07 30.60 0.00 56.66 27.57 0.00 49.58 24.36 0.02 41.76 21.04 0.03 33.10 17.62 0.03 1000 67/19 51.91 31.82 0.04 45.41 28.58 0.04 38.24 25.24 0.04 30.31 21.78 0.04 21.76 18.29 0.05 62/17 41.71 32.80 0.04 35.12 29.43 0.04 28.13 26.00 0.05 22.41 22.41 0.12 18.60 18.60 0.27 72/22 71.01 34.48 0.00 63.77 31.12 0.02 55.79 27.57 0.04 46.95 23.88 0.05 37.18 20.08 0.05 1200 67/19 58.54 36.17 0.05 51.21 32.59 0.05 43.10 28.87 0.06 34.13 25.02 0.06 24.47 21.08 0.06 62/17 47.12 37.60 0.06 39.70 33.86 0.06 31.89 30.00 0.07 25.83 25.83 0.15 21.43 21.43 0.29 72/22 77.95 37.95 0.01 70.07 34.31 0.04 61.29 30.47 0.06 51.54 26.47 0.06 40.78 22.33 0.07 1400 67/19 64.44 40.15 0.07 56.37 36.28 0.07 47.43 32.24 0.07 37.54 28.04 0.07 26.89 23.69 0.08 62/17 51.95 42.08 0.07 43.78 37.99 0.08 35.30 33.73 0.09 28.95 28.95 0.19 24.01 24.01 0.32 72/22 40.42 19.84 0.00 36.59 17.80 0.00 32.35 15.70 0.00 27.64 13.54 0.00 22.39 11.33 0.00 600 67/19 33.22 20.00 0.00 29.31 17.90 0.00 24.99 15.74 0.00 20.19 13.53 0.00 14.87 11.27 0.00 62/17 26.67 20.11 0.00 22.69 17.95 0.00 18.31 15.75 0.00 13.60 13.54 0.00 11.29 11.29 0.17 72/22 52.07 25.46 0.00 47.19 22.92 0.00 41.75 20.28 0.00 35.66 17.53 0.00 28.84 14.70 0.00 800 67/19 42.88 25.89 0.00 37.88 23.24 0.00 32.31 20.49 0.00 26.10 17.66 0.00 19.18 14.75 0.00 62/17 34.51 26.21 0.00 29.39 23.46 0.00 23.73 2064. 0.00 17.81 17.81 0.01 14.85 14.85 0.18 72/22 62.54 30.48 0.00 56.75 27.53 0.00 50.25 24.45 0.00 42.94 21.21 0.00 34.73 17.84 0.00 1000 67/19 51.63 31.28 0.00 45.66 28.17 0.01 38.98 24.93 0.01 31.49 21.55 0.01 23.12 18.06 0.01 62/17 41.65 31.91 0.01 35.51 28.66 0.01 28.71 25.30 0.01 21.89 21.89 0.03 18.26 18.26 0.19 72/22 71.89 34.94 0.00 65.33 31.70 0.00 57.89 28.24 0.00 49.50 24.59 0.00 40.06 20.76 0.00 1200 67/19 59.49 36.20 0.01 52.68 32.73 0.01 45.02 29.06 0.01 36.39 25.22 0.01 26.71 21.21 0.01 62/17 48.10 37.22 0.01 41.07 33.55 0.01 33.27 29.72 0.01 25.77 25.77 0.05 21.51 21.51 0.20 72/22 80.24 38.94 0.00 73.00 35.45 0.00 64.73 31.69 0.00 55.41 27.69 0.01 44.86 23.46 0.01 1400 67/19 66.53 40.71 0.01 58.99 36.93 0.01 50.47 32.91 0.02 40.84 28.66 0.02 29.98 24.20 0.02 62/17 53.91 42.17 0.02 46.10 38.14 0.02 37.43 00112111 145.46 33.92 0.02 29.46 29.46 0.07 24.60 24.60 0.22 72/22 57.24 28.01 0.00 51.64 25.08 0.00 22.08 0.00 38.59 19.00 0.00 30.99 15.85 0.00 750 67/19 46.98 28.35 0.00 41.29 25.33 0.00 35.01 22.24 0.00 28.09 19.09 0.00 20.47 15.90 0.01 62/17 37.67 28.59 0.01 31.89 25.50 0.01 25.61 22.37 0.01 1928. 1928. 0.02 16.05 16.05 0.19 72/22 69.68 33.97 0.00 62.89 30.52 0.00 55.32 26.92 0.00 46.89 23.21 0.00 37.57 19.40 0.00 950 67/19 57.29 34.68 0.01 50.33 31.06 0.01 42.64 27.33 0.01 34.14 23.51 0.01 24.80 19.63 0.01 62/17 45.99 35.21 0.01 38.92 31.47 0.01 31.24 27.68 0.01 23.90 23.90 0.04 19.89 19.89 0.20 72/22 80.80 39.28 0.00 72.96 35.40 0.00 64.17 31.32 0.00 54.37 27.06 0.01 43.48 22.66 0.01 1150 67/19 66.56 40.46 0.02 58.50 36.34 0.02 49.54 32.05 0.02 39.60 27.64 0.02 28.70 23.15 0.02 62/17 53.51 41.36 0.02 45.29 37.07 0.02 36.38 32.70 0.02 28.26 28.26 0.07 23.51 23.51 0.22 72/22 97.47 47.29 0.00 88.05 42.83 0.00 77.49 38.05 0.01 65.68 33.04 0.02 52.41 27.78 0.02 1500 67/19 80.52 49.40 0.03 70.85 44.58 0.03 60.01 39.53 0.03 47.89 34.25 0.03 34.64 28.83 0.04 62/17 64.96 51.12 0.03 55.02 46.04 0.03 44.30 40.80 0.04 35.27 35.27 0.10 29.34 29.34 0.25 72/22 105.61 51.26 0.00 95.43 46.52 0.01 84.03 41.43 0.03 71.21 36.06 0.03 56.82 30.42 0.03 1700 67/19 87.38 53.92 0.04 76.93 48.80 0.04 65.20 43.40 0.04 52.01 37.70 0.04 37.60 31.83 0.05 62/17 70.60 56.17 0.04 59.87 50.74 0.04 1 48.32 45.08 0.05 38.96 38.96 0.13 32.40 32.40 0.27 BOO. 72/22 76.01 37.07 0.00 68.82 33.39 0.00 60.76 29.56 0.00 51.72 25.55 0.00 41.64 21.42 0.00 1050 67/19 62.63 37.91 0.01 55.22 34.04 0.01 46.97 30.03 0.01 37.78 25.89 0.01 27.60 21.64 0.01 62/17 50.40 38.54 0.01 42.81 34.53 0.01 34.49 30.41 0.01 26.28 26.28 0.03 21.90 21.90 0.19 72/22 89.66 43.58 0.00 81.26 39.43 0.00 71.77 35.02 0.00 61.13 30.39 0.00 49.17 25.55 0.01 1300 67/19 74.04 45.04 0.01 65.36 40.60 0.01 55.62 35.94 0.01 44.72 31.09 0.01 32.62 26.09 0.01 62/17 59.73 46.18 0.01 50.78 41.52 0.02 40.97 36.70 0.02 31.77 31.77 0.06 26.48 26.48 0.21 72/22 110.09 53.41 0.00 99.92 48.64 0.00 88.41 43.46 0.01 75.38 37.95 0.02 60.66 32.13 0.02 1750 67/19 91.28 56.16 0.02 80.74 50.96 0.03 68.83 45.42 0.03 55.35 39.55 0.03 40.35 33.42 0.03 62/17 73.94 58.45 0.03 63.04 52.91 0.03 51.08 47.08 0.03 40.82 40.82 0.10 34.04 34.04 0.24 72/22 121.19 58.89 0.00 110.14 53.79 0.01 97.57 48.25 0.02 83.25 42.30 0.03 67.02 35.98 0.03 2050 67/19 100.75 62.56 0.04 89.24 56.99 0.04 76.15 51.01 0.04 61.30 44.63 0.04 44.72 37.88 0.04 62/17 81.81 65.71 0.04 69.88 59.72 0.04 56.88 53.37 0.05 46.27 46.27 0.12 38.60 38.60 0.26 72/22 126.10 61.36 0.00 114.71 56.14 0.02 101.67 50.45 0.03 86.78 44.32 0.03 69.87 37.76 0.04 2200 67/19 104.99 65.51 0.04 93.05 59.79 0.04 79.44 53.62 0.04 63.97 47.02 0.04 46.71 40.00 0.05 62/17 85.35 69.12 0.04 72.98 62.94 0.05 59.55 56.35 0.06 48.85 48.85 0.14 40.75 40.75 0.27 CFM - Cubic Ft per Minute EWB - Entering Wet Bulb (°F / °C) SHC - Gross Sensible Capacity 1000 Btuh BF - Bypass Factor NOTES: 1. Contact manufacturer for cooling capacities at conditions other than shown in table. 2. Formulas: Leaving db = entering db -sensible heat cap. 1.09 x CFM Leaving wb = wb corresponding to enthalpy of air leaving coil (hlwb) hlwb = hewb -total capacity (Btuh) 4.5 x CFM where hewb = enthalpy of air entering coil. Direct interpolation is permissible. Do not extrapolate. 3. SHC is based on 80OF db temperature of air entering coil. Below 80°F db, subtract (Correction Factor x CFM) from SHC. Above 80°F db, add (Correction Factor x CFM) to SHC. 4. Bypass Factor = 0 indicates no psychometric solution. Use by- pass factor of next lower EWB for approximation. ESTIMATED SOUND POWER LEVEL WBA) LWB - Leaving Wet Bulb (°F / °C) TC - Gross Cooling Capacity 1000 Btuh MBH - 1000 Btuh SHC CORRECTION FACTOR BYPASS FACTOR ENTERING AIR DRY-BULB TEMPERATURE ff) 79 78 77 76 75 Under75 81 82 83 84 85 Over 85 Correction Factor 0.10 .098 1.96 2.94 3.92 4.91 Use formula shown below 0.20 0.87 1.74 2.62 3.49 4.36 0.30 0.76 1.53 2.29 3.05 3.82 Interpolation is permissible. Correction Factor = 1.09 x (1 - BF) x (db - 80) MODEL SIZE CONDITIONS CFM ESP 400 0.25 OCTAVE BAND CENTER FREQUENCY 63 125 250 500 1000 2000 4000 61.0 57.0 55.0 50.0 48.0 46.0 42.0 600 0.25 62.7 58.7 56.7 51.7 49.7 47.7 43.7 FE4ANF002 800 0.25 64.0 60.0 58.0 53.0 51.0 49.0 45.0 1000 0.25 65.0 61.0 57.0 56.0 52.0 50.0 46.0 1200 0.25 65.8 61.8 57.8 56.8 52.8 50.8 46.8 1400 0.25 66.4 62.4 58.4 57.4 53.4 51.4 47.4 400 0.25 61.0 57.0 55.0 50.0 48.0 46.0 42.0 600 0.25 62.7 58.7 56.7 51.7 49.7 47.7 43.7 800 0.25 64.0 60.0 58.0 53.0 51.0 49.0 45.0 FE4ANF003 1000 0.25 65.0 61.0 59.0 54.0 52.0 50.0 46.0 1200 0.25 65.8 61.8 59.8 54.8 52.8 50.8 46.8 1400 0.25 66.4 62.4 58.4 57.4 53.4 51.4 47.4 1600 0.25 67.0 63.0 59.0 58.0 54.0 52.0 48.0 600 0.25 62.7 58.7 56.7 51.7 49.7 47.7 43.7 800 0.25 64.0 60.0 58.0 53.0 51.0 49.0 45.0 FE5ANB004 1000 0.25 65.0 61.0 59.0 54.0 52.0 50.0 46.0 1200 0.25 65.8 61.8 59.8 54.8 52.8 50.8 46.8 1400 0.25 66.4 62.4 60.4 55.4 53.4 51.4 47.4 1600 0.25 67.0 63.0 61.0 56.0 54.0 52.0 48.0 400 0.25 61.0 57.0 55.0 50.0 48.0 46.0 42.0 600 0.25 62.7 58.7 56.7 51.7 49.7 47.7 43.7 800 0.25 64.0 60.0 58.0 53.0 51.0 49.0 45.0 FE4ANF005 1000 0.25 65.0 61.0 59.0 54.0 52.0 50.0 46.0 1200 0.25 65.8 61.8 59.8 54.8 52.8 50.8 46.8 1400 0.25 66.4 62.4 58.4 57.4 53.4 51.4 47.4 1600 0.25 67.0 63.0 59.0 58.0 54.0 52.0 48.0 600 0.25 62.7 58.7 56.7 51.7 49.7 47.7 43.7 800 0.25 64.0 60.0 58.0 53.0 51.0 49.0 45.0 1000 0.25 65.0 61.0 59.0 54.0 52.0 50.0 46.0 1200 0.25 65.8 61.8 59.8 54.8 52.8 50.8 46.8 FE4ANB006 1400 0.25 66.4 62.4 60.4 55.4 53.4 51.4 47.4 1600 0.25 67.0 63.0 61.0 56.0 54.0 52.0 48.0 1800 0.25 67.5 63.5 59.5 58.5 54.5 52.5 48.5 2000 0.25 68.0 64.0 60.0 59.0 55.0 53.0 49.0 2150 0.25 68.3 64.3 60.3 59.3 55.3 53.3 49.3 *Est. sound power levels have been derived using the method described in the 1987 ASHRAE HVAC Systems & Applications Handbook, chapter 52, p. 52.7. AIRFLOW PERFORMANCE CORRECTION FACTORS HEATER kW ELEMENTS STATIC PRESSURE CORRECTION (in wc) Sizes 002-005 Size 006 0 0 +.02 +.03 5 1 +.01 +.02 8,10 2 0 0 9,15 3 -.02 -.03 20 4 -.04 -.06 18, 24, 30 6 -.06 -.10 The airflow performance table was developed using fan coils with 10kW electric heaters (2 elements) in the units. For fan coils with heaters made up of a different number of elements, the external available static at a given CFM from the table may be corrected by adding or subtracting pressure. Use table for this correction. 10 FACTORY -INSTALLED FILTER STATIC PRESSURE DROP (in wc) MODEL CFM 400 600 800 1000 1200 1400 1600 1800 2000 FE4A 002 0.020 0.044 0.048 0.072 0.100 003 - 0.020 0.035 0.051 0.070 0.092 - - - 005 - - 0.035 0.051 0.070 0.092 0.120 - - 006 - - - 0.038 0.053 0.070 0.086 0.105 0.133 MODEL CFM FE5A 400 600 800 1000 1200 1400 1600 1800 2000 004 - 0.015 0.026 0.038 0.053 0.070 - - - AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PRESSURE DROP (in wc) AT INDICATED AIRFLOW (DRY TO WET COIL) MODEL CFM FE4A 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 002 0.012 0.016 0.022 0.028 0.034 0.040 0.049 - - - - 003 - 0.026 0.034 0.042 0.052 0.063 0.075 0.083 0.091 0.098 0.110 005 - 0.006 0.008 0.010 0.012 0.015 0.017 0.020 0.023 0.027 0.030 CFM 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 006 0.013 0.016 0.018 0.020 0.023 0.027 0.030 0.034 0.039 0.044 0.048 MODEL CFM FE5A 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 004 0.004 0.005 0.007 0.009 0.011 0.013 0.016 0.018 0.020 0.023 - NOTE: Subtract the above pressure drop corrections from unit airflow data when that component or condition is used. The remaining external static pressure will be available for the duct system. UNITS WITHOUT ELECTRIC HEAT UNIT SIZE VOLTS -PHASE FLA MIN CKT AMPS BRANCH CIRCUIT Min Wire Size Awg* Fuse/Ckt Bkr Amps 002 208/230-1 4.3 5.4 14 15 003 208/230-1 4.3 5.4 14 15 005 208/230-1 4.3 5.4 14 15 004,006 208/230-1 6.8 8.5 14 15 * Use copper wire only to connect unit. If other than uncoated (non -plated) 75° C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used consult applicable tables of the National Electric Code (ANSI/NFPA 70). NOTE: If branch circuit wire length exceeds 100-ft (30.5 m), consult NEC 210-19a to determine maximum wire length. Use 2% voltage drop. FLA- Full Load Amps ACCESSORY ELECTRIC HEATERS HEATER PART NO. kW 240V VOLTS/ PHASE STAGES (kW OPERATING) INTERNAL p OTECTION CIRCUIT FAN COIL SIZE WITH HEATING CAP. @ 230V$ INTELLIGENT AT CAPABLE W OPERATING) KFCEH0501 N05 5 230/1 5 None All 15,700 - KFCEH0901N10 10 230/1 10 None All 31,400 - KFCEH3001 F15 15 230/1 5,15 Fuses** All 47,100 5, 10, 15 KFCEH3201 F20 20 230/1 5,20 Fuses** All 62,800 5, 10, 15, 20 KFCEH2901 N09 9 230/1 * 3,9 None All 28,300 3, 6, 9 KFCEH1601315 15 230/3 5,15 None All 47,100 - KFCEH3401 F24 24 230/3t 8, 16, 24 Fuses 005,006 78,500 8, 16, 24 KFCEH3501 F30 30 230/3t 10, 20, 30 Fuses 005,006 94,200 10, 20, 30 KFCEH2401 C05 5 230/1 5 Ckt Bkr All 15,700 - KFCEH2601 C1 0 10 230/1 10 Ckt Bkr All 31,400 - KFCEH3101C15 15 230/1 5,15 Ckt Bkr All 47,100 5, 10, 15 KFCEH3301 C20 20 230/1 5,20 Ckt Bkr All 62,800 5, 10, 15, 20 * Field convertible to 3 phase. Single point wiring kit required for these heaters in Canada. t These heaters field convertible to single phase. # Blower motor heat not included. ELECTRIC HEATER INTERNAL PROTECTION HEATER kW PHASE FUSES QTY / SIZE CKT BKR CITY / SIZE* 5 1 - 1 /60 8 1 - 1 /60 9 1/3 - - 10 1 - 1 /60 15 1 2/30, 2/60 2/60 15 3 - - 18 3 - - 20 1 4/60 2/60 24 3/1 6/60 - 30 3/1 6/60 - * All circuit breakers are 2 pole. 11 N ACCESSORY ELECTRIC HEATER ELECTRICAL DATA HEATER PART NO. kW P H A S E INTERNAL CIRCUIT PROTEG- TION HEATER AMPS 208/23DV BRANCH CIRCUIT Min Arn acl P N 208/230V** Min Wire Slze AWG (AWG) 208/230V11 Min Gnd Wire Six. 208/230V Max Fuse/Ckt Bkr Arn s P 208/230V Max WIre Length 9 208/230V (ft)## Single Circuit Dual Circuit Single Circuit Dual Circuit Single Circuit Dual Clrwtt Single Circuit Dual Circuit Single Circuit Dual Clmutt Single Circuit Dual Circuit 240v 208v L1,L2 L3,L4 L1,L2 L3,L4 L1,L2 L3,L4 L1,L2 L3,1_4 L1,L2 L3,L4 KFCEH0501N05 5 3.8 1 None 18.1/20.0 — — 312/33.5 — — 8/8 — — 10/10 — — 35/3585/88 — — KFCEH2401C05 5 3.8 1 Ckt Bkr 18.1120.0 — — 31.2133.5 — — 8/8 — — 10110 — — 35/3585/88 TRL4 — — KFCEH0801N08 8 6.0 1 None 28.9/32.0 — — 447/485 — — 8/8 — — 10110 — — 45/5059/60 — — KFCEH2501CD8 8 6.0 1 Gkt Bkr 28.9/32.0 — — 447/485 — — 8/8 — — 10/10 — — 45/5059160 — — KFCEH2901ND9* 9 6.8 1 None 32.8/36.0 — — 49.5/53.5 — — 8/6 — — 10/10 — — 50/6054187 — — KFCEH2901ND9*t 9 6.8 3 None 18.8/20.8 — — 32.0/34.5 — — 8/8 — — 10/10 — — 35/35 — — 83/85 — — KFCEH0901N10 10 7.5 1 None 36.2/40.0 — — 53.8/5B.5 — — 6/6 — — 10/10 — — 60/60 — — 78180 — — KFCEH2601C10 10 7.5 1 Ckt Bkr 36.2/40.0 — — 53.8/58.5 — — 6/6 — — 10/10 — — 60/60 — — 7B/80 — — KFCEH3001F15*1 15 11.3 1 Fuse 54.W59.9 36.2140.0 18.1/20.0 76.3/83.4 53.8/58.5 22.7/25.0 4/4 6/6 10/10 8/8 10/10 10/10 80/90 60/60 25/25 88/89 78/80 75/76 KFCEH3101C15* 15 11.3 1 Ckt Bkr — 36.2140.0 18.1/20.0 — 53.8/58.5 22.7125.0 — 6/6 10/10 — 10/10 10/10 — 60/60 25/25 — 78/80 75/76 KFCEH1601315 15 11.3 3 None 31.3134.6 — — 47.7/51.8 — — 8/6 — — 10/10 — — 50/60 — — 56190 — — KFCEH2O01318 18 13.5 3 None 37.6/41.5 — — 55.5/60.4 — — 6/6 — — 10/8 — — 60/70 — — 76/77 — — KFCEH3201F20*1 20 15.0 1 Fuse 72.3/79.9 36.2/40.0 36.2/40.0 98.9/10B.4 53.8/58.5 45.3/50.0 3/2 6/6 8/8 8/6 10/10 10/10 100/110 60/60 50/50 W109 78/80 59/59 KFCEH3301C20* 20 15.0 1 Ckt Bkr — 362/40.0 36.2/40.0 — 53.8/58.5 45.3/50.0 — 6/6 8/8 — 10/10 10110 — 60/60 50/50 — 78/80 59/59 KFCEH3401F24*t 24 18.0 3 Fuse 50.1155.4 — — 71.2/77.8 — — 4/4 — — 8/8 — — 80/80 — — D4/95 — — 24 18.0 1 Fuse 86.7/95.5 — — 116.9/127.9 — — 1/1 — — 6/6 — — 125/150 — — 115/116 — — KFCEH3501F30*t 30 22.5 3 Fuse 62.6/69.2 — — 86.8/95.0 — — 3/3 — — 8/8 — — 90/100 — — 97198 — — 30 22.5 1 Fuse 109.0I120.0 — — 144.6/158.5 — — 0/00 — — 6I6 — — 150/175 — — 117/150 — — FIELD MULTIPOINT WIRING OF 24-AND 30-kW SINGLE PHASE KW P H HEATER AMPS MIN AMPACITY MIN WIRE SIZE (AWG) MIN MAX FUSE/CKT BKR AMPS MAX WIRE LENGTH HEATER PART ASIZ 208/230V 208/230V** 208/230Vtt WIRE SIZE 208/230V 208/230V (FT)## NO. S 208/230V 240V 208V L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5, L6 L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 E KFCEH340l F24*t 24 18.0 1 28.9/32.0 28.9/32.0 28.9/32.0 44.7/48.5 36.2/40.0 36.2/40.0 8/8 8/8 8/8 10/10 45/50 40/40 40/40 59/60 73/73 73/73 KFCEH350l F30*t 30 22.5 1 36.2/40.0 36.2/40.0 36.2/40.0 53.8/58.5 45.3/50.0 45.3/50.0 6/6 8/8 8/8 10/10 60/60 50/50 50/50 78/80 1 59/59 59/59 * Heaters are Intelligent Heat capable when used with the FE fan coil and Zone Perfect Plus- or Evolution Control-. t Field convertible to 1 phase, single or multiple supply circuit. $ Field convertible to 3 phase. ** Includes blower motor amps of largest fan coil used with heater. tt Copper wire must be used. If other than uncoated (non -plated), 750C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the National Electric Code (ANSI/NFPA 70). $$ Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%. NOTES: 1. Single circuit application of F15 and F20 heaters requires single -point wiring kit accessory. ACCESSORIES REQUIRED ACCESSORY ACCESNOORY PART ITEM FAN COIL SIZE USED WITH Evolution® Connex- Control with Integrated Wi—Fi SYSTXBBECC01 All or 1. Evolution@ Connex- Control Wi—Fi with bundled router SYSTXBBECW01 All or Evolution® Connex— Control SYSTXBBECN01 All ADDITIONAL ACCESSORIES ITEM ACCESNOORY PART FAN COIL SIZE USED WITH 2. Evolutions Series 4 Zone Board SYSTXBB4ZC01 All 3. Evolution@ Series Smart Sensor SYSTXBBSMS01— D All 4. Evolution@ Remote Room Sensor SYSTXBBRRS01 All 5. Evolution® Series Network Interface Module SYSTXBBNIM01 All 6. Disconnect Kit KFADK0201 DSC Cooling controls and heaters 3— through 10—kW 7. Downflow Base Kit KFACB0201 CFB 002 KFACB0301 CFB 003,005 KFACB0401 CFB 004,006 8. Downflow Conversion Kit KFADCO201 SLID 003 KFADC0401ACL 002, 004, 005, 006 9. Single —Point Wiring Kit KFASP0101SPK Only with 15— and 20—kW Fused Heaters 10. Filter Kit (12 Pack) Filter Media Cabinet KFAFK0212MED 002 KFAFK0312LRG 003,005 KFAFK0412XXL 004,006 11. FNCCABBB0017 002 FNCCABBB0021 003,005 FNCCABBB0024 004,006 12. Media Filter Cartridges FILBBFNCO017 002 FILBBFNCO021 003,005 FILBBFNCO024 004,006 13. Evolutions Series Air Purifier GAPABXBB1620 002 GAPABXBB2020 003,005 GAPABXBB2024 004,006 14. PVC Condensate Trap Kit (50 pack) KFAET0150ETK All 15. Air Cleaner 240—volt Conversion Kit KEAVCO201240 All 16. Downflow/Horizontal Conversion Gasket Kit KFAHDO101 SLP All 17. Airflow Sensor Kit (Air Cleaner) KEAAC0101AAA All 18. Horizontal Water Management Kit (25 pack) KFAHCO125AAA All 19. Standard Filter Rack Kit KFAFR0101 FRM NA KFAFR0201 FRM 002 KFAFR0301 FRM 003,005 KFAFR0401 FRM 004,006 20. Hydronic Relay Interface Kit KFAIF0101 HWC All * Factory authorized and listed, field installed. 13 ACCESSORIES (CONT.) Accessory Kits Description Suggested and Required Use 1. EvolutionO Conner' Control with Integrated Wi-Fi Deluxe programmable wall -mounted system control with integrated Wi-Fi. or Evolution® Connex- Control Wi-Fi with bundled router Deluxe programmable wall -mounted system control with integrated Wi-Fi. Sold bundled with Wi-Fi router or Evolution® Connex- Control Deluxe programmable wall -mounted system control without remote access. 2. Evolution® 4 Zone Board 4-Zone Damper Control Module wall -mounted control. REQUIRED USE: For all four -zone systems. For systems with 5 to 8 zones, a second Damper Control Module is required. 3. Evolution® Smart Sensor Wall control used to monitor temperature and/or fan control. SUGGESTED USE: For use in zone systems. 4. EvolutionO Remote Room Sensor Wired remote temperature sensor for zone control. SUGGESTED USE: For use in zone systems.. 5. Evolution® Series Network Interface Module Connects Heat Recovery and Energy Recovery Ventilators on non -zoning applications and non -communicating 2-speed units. REQUIRED USE: For non -zoned systems installed with HRV or ERV, Hybrid Heat with non -communicating heat pumps or non - communicating 2-speed units. 6. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. SUGGESTED USE: Units for 3- through 10-kW electric resistance heaters and cooling controls. 7. Downflow Base Kit This kit is designed to provide a 1-in. minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides a gap -free seal with the floor. REQUIRED USE: This kit must be used whenever fan coils are used in downflow applications. 8. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal -left applications. Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications. Separate kits are available for slope coils and A -coils. REQUIRED USE: This kit must be used whenever fan coils are used in downflow applications. 9. Single Point Wiring Kit The single point wiring kit acts as a jumper between L1 and L3 lugs, and between the L2 and L4 lugs. This allows the installer to run 2 heavy -gauge, high -voltage wires into the fan coil rather than 4 light -gauge, high -voltage wires. SUGGESTED USE: Fan coils with 15- and 20-kW fused heaters only. 10. Filter Kit (12 pack) The kit consists of 12 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and, in turn, the efficiency of the system. SUGGESTED USE: To replace filters in fan coils. REQUIRED USE: All units unless a filter grille is used. 11. Filter Media Cabinet This cabinet is mounted to the fan coil on the return air end and designed to slip over the outer fan coil casing. The cabinets are insulated using the same insulation as production fan coils. They are designed for the removal of particulates from indoor air using FILCCFNC00(14, 17, 21, 24) media filter cartridges. SUGGESTED USE: All fan coils. 12. Media Filter Cartridges These fan coil media filter cartridge kits are designed for the removal of particles from indoor air. The cartridge is installed in the return air duct next to the air handler or further upstream. SUGGESTED USE: All fan coils. 13. Evolution® Series Air Purifier The Evolution Series Air Purifier wires directly to fan coil and requires no duct transitions with Bryant units. It comes with an airflow sensor. SUGGESTED USE: All fan coils. 14. Condensate Drain Trap Kit This kit consists of 50 PVC condensate traps. Each trap is pre -formed and ready for field installation. This deep trap helps the system make and hold proper condensate flow even during blower initiation. SUGGESTED USE: All fan coils. 15. Air Cleaner 240-volt Conversion Kit The AIRA electronic air cleaner comes ready for 115-v operation. REQUIRED USE: This kit is required when running 240-volt circuit to air cleaner. 14 ACCESSORIES (CONT.) 16. Downflow/Horizontal Conversion Gasket Kit This kit provides the proper gasketing of units when applied in either a downflow or horizontal application. REQUIRED USE: Fan coils in either downflow or horizontal applications. 17. Airflow Sensor Kit (Air Cleaner) The AIRA electronic air cleaner comes ready for 115-v operation REQUIRED USE: This kit is required whenever an electronic air cleaner is used. 18. Horizontal Water Management Kit This kit provides proper installation of fan coils under conditions of high static pressure and high relative humidity. SUGGESTED USE: All fan coils (except FE5 and 17171). 19. Standard Filter Rack Kit This kit mounts in fan coil filter rack area and modifies the existing filter rack to support standard 1-in. filter sizes. SUGGESTED USE: Fan coils using standard filter sizes. 20. Hydronic Relay Interface Kit This kit provides interface of the FE4 and FE5 fan coils with Hydronic Heat equipment. NOTE: Electric heat cannot be used with Hydronic Interface Relay Kit. SUGGESTED USE: All FE4 and FE5 fan coils installed with hydronic heat. 15 ©2014 Bryant Heating & Cooling Systems • 7310 W. Morris St. • Indianapolis, IN 46231 Edition Date: 02/14 U.S. Export Classification: EAR99. Catalog No. PDSFE4A-09 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Replaces: PDSFE4A-08 16