Loading...
APPROVED BLD2024-1164+Mechanical_Plan+9.6.2024_10.22.28_AM+44844580 Q) U 0 U O U O L N 0- Q �I O W C a- = LL X Lu O rl- Lf ) O 0 N X L CL 0 W U w Q O 0 LO 0 0 N X LD .C� C aj o� U) FL USF-1 Dx ow U C:) Eo �o am X Ln — _-E o� N O — N C �a- U C 0 U io 0- 0 o D oI �LO wo i o X o C N E o_ o i� U E U M vJ iL Q 0 N a- 0)O� �: r-- -0 LO � o U N X 0 0 0� W 0 U � Q � o O O r— LO Ln o o O N C:)X -0 CO 0 ~ E O� r- w LO o 0 U U o a- X m Q M U m ci) 0 X M 3/4"RMC, 2#10 & 1 #10G a T UTILIZE EXISTING EF-3 EXHUAST FAN EX MCC 601A TANDEM BUCKET LOCATED IN THIS O APPX LOCATION. REPLACE EXISTING BREAKERS AS REQUIRED EXISTING 480V — JUNCTION BOX = EX MCC 601 B EX PLC-601 a, �0 _ = P1 d •. a I P2 . d I I • d °' y ° i ° e d •. / P3 � ♦— 5'-4" E F-3 = I � NEMA 4X T-STAT I� ilk ----- GASIFIER ROOM AIR SUPPLY FANS 1AI SOLIDS HANDLING ROOM EXHAUST FAN SUSPENDED FROM CEILING I. 5'x5' Louver SERVICE RECEPTACLE FOR HVAC EQUIPMENT AT MAU-1 1"C,6#14 — ZSS G-601 2"RMC/LFMC, 1-3/C#10VFD & 4#12 /TO SCREEN I IN( CONTROL PAN 101 M�A 19 N _ E F-4 1-1/2"RMC/LFMC, 1-3/C#10VFD & 2#12 C-601 — LSH K LT 3/4"RMC/ LFMC, 2#14 _ SCREENINGS CONTROL PANEL (SC-601) P7 TO SCREENINGS 3/4"RMC, 1-2/C#16STP MCC 601 B NEMA 4X VFD FURNISHED BY OTHERS ° CONTROL SEQUENCE: b d• e e . ° °' :. a / a NOTES: • a d 1. PROVIDE INTERCONNECTIONS AS DESIGNED BY ECOREMEDY. CONSTRUCTION NOTES: U PROVIDE ENCLOSED CIRCUIT BREAKER. CIRCUIT BREAKER MUST BE A 3P-600A OR LARGER FRAME, 450A TRIP SETTING. PROVIDE CIRCUIT BREAKER IN A NEMA 4X ENCLOSURE. 2O PROVIDE CURRENT TRANSMITTER PER HVAC. INSTALL SENSOR ON POWER BRANCH CIRCUIT. PROVIDE SEPARATE MAGNETIC MOTOR CONTACTOR FOR EACH MOTOR CONTROLLED BY 24VDC PLC SIGNAL. ARRANGE CIRCUIT SUCH THAT MOTOR DAMPER ASSOCIATED WITH FAN IS CONTROLLED BY SAME CONTACTOR. EF3 — FAN IS TURNED ON OFF BY AMBIENT TEMPERATURE SENSOR LOCATED NEAR LOCATION AS SHOWN. SPEED OF FAN IS ADJUSTED MANUAL BY LOCAL SPEED CONTROL ON VFD. CURRENT SENSING SWITCH WILL BE PLACED IN MCC BUCKET WITH AN DISCRETE "RUNNING" SIGNAL WILL BE TRANSMITTED TO PLC-01. 11-I-------- EF4 — FAN IS TURNED ON/OFF BY AMBIENT TEMPERATURE SENSOR LOCATED ---1"---2/C#-- NEAR LOCATION AS SHOWN. SPEED OF FAN IS ADJUSTED MANUAL BY RM C,1"RMC, 1 CAT6 & 2-2/C#16STP LOCAL SPEED CONTROL ON VFD. CURRENT SENSING SWITCH WILL BE PLACED IN MCC BUCKET WITH AN DISCRETE "RUNNING" SIGNAL WILL BE 11�RMc, 3#10 & 1#10G TRANSMITTED TO PLC— 01 . EF-1 GASSIFICATION ROOM EXHAUST FAN VFD, SEE HVAC 5X5 LOUVER — MANUALLY CONTROLLED 111RMC,2-2/C#16STP i CONDUIT SCHEDULE: 3/4"RMC, 1-2/C#16STP CURRENT SENSORS 20 C 1 — 3 / 4 " , NEW, 4 # 14 FOR EF-2, EF-3 C2 — 3/4", NEW, 2#14 C3 — 3/4", NEW, 2#14 P1 — 3/4", NEW, 5#12 P2 — 4", EXISTING, 5#12 P3 — 3/4", NEW, 5#12 P4 — 3/4", NEW, 3#12 NEMA 4X VFD P 5 — 3 / 4 " , NEW, 3 # 12 4 — — FURNISHED BY OTHERS ---� TT- —_ P 6 — 3 / 4 " , NEW, 3 # 12 — — -----r � -- P 7 — 3/4 " , NEW, 3 # 12 L—_ J CONTROL PANEL MOTORIZED DAMPER q ° ° °. 1 "C, 8#14 & 3/4"C, $ Wp ® $ Wp M EF-2 EXHAUST FAN 2#12 & 1 #12G M M bh(;BHC Consultants, LLC Designed: N. Palmatier, P.E. 1601 Fifth Avenue, Suite 500 Seattle, Washington 98101 206.505.3400 Drawn: S.Olsoe ISSUED FOR CONSTRUCTION 10-2021 GRM RAID 206.505.3406 (fax) No. I Revision Date I By I App'd CONSULTANTS www.bhcconsultants.com Checked: G. Mockos, P.E. a• a •a e NEMA 4X T-STAT SCREENING WATER CONTROL PANEL - Scale 1/4" = 1'-0" One Inch at Full Scale If Not One Inch Scale Accordingly ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE AMERESCO Green •Clean •Sustainable � APPROVED PLANS MUST BE ON JOB SITE City Of Edmonds Building Department Work 2 FAMES AND LOUVER Address 200 2ND AVE S Owner WWTP Approved Date 09/09/2024 Building Official Erik C wfe r Permit Number BLD2024-1164 EDMONDS WWTP CARBON RECOVERY SOLIDS PROCESSING BUILDING SOLIDS HANDLING ROOM ELECTRICAL PLAN IVED i°0 OF'EDMONDS III 48 Hours )re You Dig .800-424-5555 NDERGROUND SERVICE WA 44806 GIST ��ti �slONAL �G 10/Ia/20.t � Drawing: E-9 Sheet: 108 of 114 File: P20-10570_E-9 Date: October 2021 COPYRIGHT © 2021 BHC CONSULTANTS, LLC. ALL RIGHTS RESERVED