APPROVED BLD BLD2022-0906+Architectural_or_Building_Floor_Plans+7.11.2022_10.53.25_AM+298059630'-0 3/4"
FT'Nommill IN 11111191191 Oki• , ,
SCALE: 1 /4" = 1 '-0"
Approved by Fire
08/01/2022 AFM IC�Gt�ef e{
■ ■ ■�■�■ !
The route to the of primary
'function area, including toilet !
facilities and drinking !
fountains serving the area of ■
.primary function, shall be '
!accessible. The costs of ■
providing the accessible routel
are not required to exceed 20
■percent of the costs of the i
!alteration affecting the area of
ithe primary function. !
■IEBC410.7/705.2/806.1 / !
1906.1 / 1012.8.1 / 1105.1
• 1204.1 / 1401.2.5 !
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
}o
Z Q co
�inQmrn
�0o��
� Z n
LU 0 r'j
ULn�
�k Ln
0
y
�a
E�
M
Ln U�
p�
'LLn
i � N
0 -0 -T
RECEIVED
City
Of Edmonds
Building
Department
------------------------------------------------------
Work
T.I. CHNG OF USE
--------------------
Address
-------------------,
115 5TH AVE S
----------------
Owner
-------------
JUICE N JOE
------------
Approved Date
--------------------
8/08/2022
Building Official__
D07LOTITiL W. W 09'�& ;
----------------
Permit Number
-------------------------------------
-----------
BLD2022-0906
Jul 1 2022
CITY
:VELD MENT SERVICES
DATE:
7/11/2022
SCALE:
1/4" = 1'-0"
SHEET:
J
The route to the of primary
'function area, including toilet
facilities and drinking !
fountains serving the area of ■
.primary function, shall be !
!accessible. The costs of ■
providing the accessible route!
are not required to exceed 20
.percent of the costs of the !
!alteration affecting the area of
ithe primary function. !
■IEBC410.7/705.2/806.1 / !
1906.1/1012.8.1/1105.1/ '
1204.1 / 1401.2.5 !
SCALE: 1/4" = 1'-0"
JUICE N JOE
Proposed Business: Juice bar, serving
fresh -made juice, coffee, and snacks.
Zoning: BD1
Building type of Construction: VB
No sprinkler system provided.
No fire alarm system provided.
Deferred submittals not included
Plumbing
All Walls to remain in same location.
No proposed shelving racks over 6ft in
height.
Upper cabinet storage in kitchen and
utility area.
Heating: Wall heater & electric fireplace
provides heat.
Ventilation: Bathroom ceiling vent &
register, windows and doors otherwise.
See Fire Safety Plan (sheet A5.0) for fire
safety details.
Equipment:
1: Refrigerator - 60" tall
2: Hot water heater - existing
3: Under counter refrigerator
4: Under counter refrigerator
5: Under counter Ice Maker
SINKS & USAGE:
A: Main Sink: Used for dishwashing &
cleaning.
B: Hand Washing Sink: Used for hand
washing only
C: Prep Sink: Used for dispensing and
dumping water &juice
D: Mop Sink: Used for rinsing mop only
E: Hand Sink: Used for hand washing
only
Grease trap to be located near the main
sink (A).
ADA Notes:
We are requesting possible exception to
restroom size per WAC 51-50-3411,
exception #1 of 3411.7.
Upgrades for ADA compliance to be
performed in proposed plan:
• Change of door swing of front door
to swing outward to meet 18"
clearance compliance, found in 404.2
of ADA standards. This will require
purchase of new door.
• Change back room door to a doorway
for compliance with 18" door
clearance.
• Remove current sink in bathroom and
install ADA compliant sink.
• Lever handles on all doors.
• Grab bars upgraded in bathroom.
• Mirror above sink at ADA height.
• Countertops built at ADA height.
OCCUPANCY CALCULATIONS
OCCUPANCY LOAD: PER 2018 IBC
TABLE 1004.5
OCCUPANCY CLASSIFICATION:
GROUP B
0
}o
Z Q co
�U)<rn
�0
cc: Ln
=wOr"j"J
E
O
U
ca
E
M
Ln
LLn
i � N
0-0-T
Assembly (chairs only - not fixed) = 5
net SF per allowance per occupant = w
7.5 x 9.75 = 73sf / 5net = 11 "
Kitchen Commercial = 60 gross sf
per allowance per occupant = 11.66
x 21.58 = 241 sf / 200gross = 2
TOTAL OCCUPANT LOAD= 13
TOTAL SPACE: 360 SQ FT
EXITS: 2
EXITS REQUIRED: 1
0
LU
U)
O
d Z
� J
d �
RECEIVED
Jul 1 202
M2
CITY
:VELD ENT SERVICES
(D
C)
0
m
rn
J J In j
Q O Q
z z
m O
w L o
0 — w
DATE:
7/11/2022
SCALE:
1/4" = 1'-0"
SHEET:
Interior• • - Building Area • •
Compliance with 2018 YVashington State Energy Code Date: 3.25.2021
Calculation Area: Spaces where the Use is changing Project Title: Juice N Joe
LPA Calculation Type: Standard
Maximum Allowed Lighting Wattage
Wafts
Gross
Allowed
Allowed
Interior
Watts per
(waits/ft" x
Building Area
Location (plan#, room*, or ALL
Area Description
Area in T
ft`
area)
Retail
ALL
Retail Juice Bar
327
1.060
347
Total Area 327
Retail Display Allowance from LTC—INT-DISPLAY 0
Allowed Watts 347
Proposed Lighting Wattage "ores
Wafts/
Location (plan #,
Number of
FbdureNOTC
Wafts
Building Area
room#1
Fixture Description NOTC4'ia
Fixtures
7
Proposed
Retail
Energy Compliance Plan
Existing Can Lights
6
48
Energy Compliance Plan
Existing Bathroom light
1
8
8
Reflected Ceiling Plan
Existing 2x4 light
2
56
112
Energy Compliance Plan
Existing Sconce
1
10
10
Energy Compliance Plan
Existing Track lights. 12 ft. so(
bulbs
1
30
31-1
0
Proposed Retail Display Lighting from LTG-INT-DISPLAY 0
■
Total Proposed Watts may not exceed Total AUovredWatts For Interior Lighting Total Proposed 208
Interior Lighting Power Allowance COMPLIES
Lighting Zone to remain the same: Zone 2, per
Table C405.4.2(1)
One sconce, and accent light to be removed from
previous use. All other existing fixtures, can lights,
switches to remain. No increase in wattage.
Proposed wattage does not exceed maximum
allowed per compliance path.
Egress Exit signs
Specs included.
Lighting Power Density = Watts/SF
Each Exit sign = 3 Watts
3/360SF=.016 Watts/SF
Under .02 Watts/SF. No need for automatic shutoff
controls.
No amp circuit controlled by a single switch or
automatic control will be loaded beyond 80%.
All equipment (refrigerators and ice machines)
shown in plan. Specs included.
Project close out documentation will include WSEC
lighting compliance reports, and address all interior
and exterior lighting area and/or surface types,
lighting power allowances and installed densities
Daylight Zone
Sidelit 7' 5" x 112"
atts per SF
o match 201
ode require
uilding area
FIXTURE SCHEDULE
-
12 ft Track Lighting, six bulbs - Existing
Sconce - Existing
p
Exit Lights
Electrical Panel - Existing
$
Switches - Existing
rGan
lights - Existing
Double Switch - Existing
SCALE: 1/4" = 1'-0"
\ iffillil i o M111, , 10
SCALE:
C
O
U
E
rn
U
� C�J
in Ln
i � N
0 -0 -T
0
z
J }
W
U Of W
0 W U
W Z Z
H W Q
Li 0
W °6 J
w
LLZ�
Wa0
EIVED
1 2022
SERVICES
0
CV
0
00
U rn
J J xn j
LU
z z
m O
in U ,n
L E5 7 o
cif- w
DATE:
7/11/2022
SCALE:
1/4" = 1'-0"
SHEET:
FAMIC
CD
}o
Z Q 00
�inQmrn
� ko
J of
cc: Q n
LU 0
UL^�
�k Ln
Countertop to be no more
than 34" for ADA compliance.
E
11' 2" 11' 2" O
ca
a E3 I rrn
E5 @
c ' Ln In
E1 E2 i o-0'
® � E4 JU
2'-11 1/2",I I EEE b' 2 1/2"b'-2" E 3'
WEST JUICE BAR ELEVATIONSCALE: 1/4" = V-0" SCALE: 1/4" = V-0"
2q'-1 1/4" 11'-2"
Z
O
Q
�w
w J
W
RECEIVED
Jul 11 2022
7
Cn CITY
DEVELOPMENT SERVICES
■ DE ARTMENT
CD
I� �1 5' 2" 4' b" V o
E E 00
1' 3 3/4" <
3'-1" q'-3" 4'-5" 5'-b" Q � vi LU �
1 q'-2" O LU vi
t Q o
E3 Countertop to be no more E4 E5 OUTH BACK ROOM ELEVATION N LU Ln 0
SCALE: 1/4" = V-0" than 34" for ADA compliance. SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" 0 - o
DATE:
7/11/2022
SCALE:
SHEET:
A4.0
CD
}o
Z Q 00
�inQmrn
�0
cc: Q Z n
LU 0 r'j
ULn�
�k Ln
Equipped with smoke o
detectors and a fire
extinguisher. E r,-
M
�V
No fire doors, fire partitions,
REQUIRED FIRE EXIT: 1 or pull stations. °'Ln
EXITS PROVIDED: 2 0 -0 �
OCCUPANCY: 13 Egress lighting specs
included in Lighting
Smoke Detector
Summary documents.
0 ,
0
E �EXIT L J 5D
� E E E y_•�
3 0 o Fire Extinguisher
m LL
X Q
Smoke Detector 5° 07
w Z
W
� � � ❑ ® � � e Electrical Panel � J
LL. d
RECEIVED
W2436R W2436R 436L 1IQ436L S
[EXIT] J u l 11 2022
CITY
DEVELOPMENT SERVICES
DE ARTMENT O
CD
O
co
V M
J J In Q
FIRE SAFETY PLAN Q o Q
SCALE: 1 /4" = 1'-0" N Lu Ln 0
L2
w R�o
—w
DATE:
7/11/2022
SCALE:
1/8" = 1'-0"
SHEET:
A5.0