Loading...
APPROVED BLD BLD2022-0906+Architectural_or_Building_Floor_Plans+7.11.2022_10.53.25_AM+298059630'-0 3/4" FT'Nommill IN 11111191191 Oki• , , SCALE: 1 /4" = 1 '-0" Approved by Fire 08/01/2022 AFM IC�Gt�ef e{ ■ ■ ■�■�■ ! The route to the of primary 'function area, including toilet ! facilities and drinking ! fountains serving the area of ■ .primary function, shall be ' !accessible. The costs of ■ providing the accessible routel are not required to exceed 20 ■percent of the costs of the i !alteration affecting the area of ithe primary function. ! ■IEBC410.7/705.2/806.1 / ! 1906.1 / 1012.8.1 / 1105.1 • 1204.1 / 1401.2.5 ! OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE }o Z Q co �inQmrn �0o�� � Z n LU 0 r'j ULn� �k Ln 0 y �a E� M Ln U� p� 'LLn i � N 0 -0 -T RECEIVED City Of Edmonds Building Department ------------------------------------------------------ Work T.I. CHNG OF USE -------------------- Address -------------------, 115 5TH AVE S ---------------- Owner ------------- JUICE N JOE ------------ Approved Date -------------------- 8/08/2022 Building Official__ D07LOTITiL W. W 09'�& ; ---------------- Permit Number ------------------------------------- ----------- BLD2022-0906 Jul 1 2022 CITY :VELD MENT SERVICES DATE: 7/11/2022 SCALE: 1/4" = 1'-0" SHEET: J The route to the of primary 'function area, including toilet facilities and drinking ! fountains serving the area of ■ .primary function, shall be ! !accessible. The costs of ■ providing the accessible route! are not required to exceed 20 .percent of the costs of the ! !alteration affecting the area of ithe primary function. ! ■IEBC410.7/705.2/806.1 / ! 1906.1/1012.8.1/1105.1/ ' 1204.1 / 1401.2.5 ! SCALE: 1/4" = 1'-0" JUICE N JOE Proposed Business: Juice bar, serving fresh -made juice, coffee, and snacks. Zoning: BD1 Building type of Construction: VB No sprinkler system provided. No fire alarm system provided. Deferred submittals not included Plumbing All Walls to remain in same location. No proposed shelving racks over 6ft in height. Upper cabinet storage in kitchen and utility area. Heating: Wall heater & electric fireplace provides heat. Ventilation: Bathroom ceiling vent & register, windows and doors otherwise. See Fire Safety Plan (sheet A5.0) for fire safety details. Equipment: 1: Refrigerator - 60" tall 2: Hot water heater - existing 3: Under counter refrigerator 4: Under counter refrigerator 5: Under counter Ice Maker SINKS & USAGE: A: Main Sink: Used for dishwashing & cleaning. B: Hand Washing Sink: Used for hand washing only C: Prep Sink: Used for dispensing and dumping water &juice D: Mop Sink: Used for rinsing mop only E: Hand Sink: Used for hand washing only Grease trap to be located near the main sink (A). ADA Notes: We are requesting possible exception to restroom size per WAC 51-50-3411, exception #1 of 3411.7. Upgrades for ADA compliance to be performed in proposed plan: • Change of door swing of front door to swing outward to meet 18" clearance compliance, found in 404.2 of ADA standards. This will require purchase of new door. • Change back room door to a doorway for compliance with 18" door clearance. • Remove current sink in bathroom and install ADA compliant sink. • Lever handles on all doors. • Grab bars upgraded in bathroom. • Mirror above sink at ADA height. • Countertops built at ADA height. OCCUPANCY CALCULATIONS OCCUPANCY LOAD: PER 2018 IBC TABLE 1004.5 OCCUPANCY CLASSIFICATION: GROUP B 0 }o Z Q co �U)<rn �0 cc: Ln =wOr"j"J E O U ca E M Ln LLn i � N 0-0-T Assembly (chairs only - not fixed) = 5 net SF per allowance per occupant = w 7.5 x 9.75 = 73sf / 5net = 11 " Kitchen Commercial = 60 gross sf per allowance per occupant = 11.66 x 21.58 = 241 sf / 200gross = 2 TOTAL OCCUPANT LOAD= 13 TOTAL SPACE: 360 SQ FT EXITS: 2 EXITS REQUIRED: 1 0 LU U) O d Z � J d � RECEIVED Jul 1 202 M2 CITY :VELD ENT SERVICES (D C) 0 m rn J J In j Q O Q z z m O w L o 0 — w DATE: 7/11/2022 SCALE: 1/4" = 1'-0" SHEET: Interior• • - Building Area • • Compliance with 2018 YVashington State Energy Code Date: 3.25.2021 Calculation Area: Spaces where the Use is changing Project Title: Juice N Joe LPA Calculation Type: Standard Maximum Allowed Lighting Wattage Wafts Gross Allowed Allowed Interior Watts per (waits/ft" x Building Area Location (plan#, room*, or ALL Area Description Area in T ft` area) Retail ALL Retail Juice Bar 327 1.060 347 Total Area 327 Retail Display Allowance from LTC—INT-DISPLAY 0 Allowed Watts 347 Proposed Lighting Wattage "ores Wafts/ Location (plan #, Number of FbdureNOTC Wafts Building Area room#1 Fixture Description NOTC4'ia Fixtures 7 Proposed Retail Energy Compliance Plan Existing Can Lights 6 48 Energy Compliance Plan Existing Bathroom light 1 8 8 Reflected Ceiling Plan Existing 2x4 light 2 56 112 Energy Compliance Plan Existing Sconce 1 10 10 Energy Compliance Plan Existing Track lights. 12 ft. so( bulbs 1 30 31-1 0 Proposed Retail Display Lighting from LTG-INT-DISPLAY 0 ■ Total Proposed Watts may not exceed Total AUovredWatts For Interior Lighting Total Proposed 208 Interior Lighting Power Allowance COMPLIES Lighting Zone to remain the same: Zone 2, per Table C405.4.2(1) One sconce, and accent light to be removed from previous use. All other existing fixtures, can lights, switches to remain. No increase in wattage. Proposed wattage does not exceed maximum allowed per compliance path. Egress Exit signs Specs included. Lighting Power Density = Watts/SF Each Exit sign = 3 Watts 3/360SF=.016 Watts/SF Under .02 Watts/SF. No need for automatic shutoff controls. No amp circuit controlled by a single switch or automatic control will be loaded beyond 80%. All equipment (refrigerators and ice machines) shown in plan. Specs included. Project close out documentation will include WSEC lighting compliance reports, and address all interior and exterior lighting area and/or surface types, lighting power allowances and installed densities Daylight Zone Sidelit 7' 5" x 112" atts per SF o match 201 ode require uilding area FIXTURE SCHEDULE - 12 ft Track Lighting, six bulbs - Existing Sconce - Existing p Exit Lights Electrical Panel - Existing $ Switches - Existing rGan lights - Existing Double Switch - Existing SCALE: 1/4" = 1'-0" \ iffillil i o M111, , 10 SCALE: C O U E rn U � C�J in Ln i � N 0 -0 -T 0 z J } W U Of W 0 W U W Z Z H W Q Li 0 W °6 J w LLZ� Wa0 EIVED 1 2022 SERVICES 0 CV 0 00 U rn J J xn j LU z z m O in U ,n L E5 7 o cif- w DATE: 7/11/2022 SCALE: 1/4" = 1'-0" SHEET: FAMIC CD }o Z Q 00 �inQmrn � ko J of cc: Q n LU 0 UL^� �k Ln Countertop to be no more than 34" for ADA compliance. E 11' 2" 11' 2" O ca a E3 I rrn E5 @ c ' Ln In E1 E2 i o-0' ® � E4 JU 2'-11 1/2",I I EEE b' 2 1/2"b'-2" E 3' WEST JUICE BAR ELEVATIONSCALE: 1/4" = V-0" SCALE: 1/4" = V-0" 2q'-1 1/4" 11'-2" Z O Q �w w J W RECEIVED Jul 11 2022 7 Cn CITY DEVELOPMENT SERVICES ■ DE ARTMENT CD I� �1 5' 2" 4' b" V o E E 00 1' 3 3/4" < 3'-1" q'-3" 4'-5" 5'-b" Q � vi LU � 1 q'-2" O LU vi t Q o E3 Countertop to be no more E4 E5 OUTH BACK ROOM ELEVATION N LU Ln 0 SCALE: 1/4" = V-0" than 34" for ADA compliance. SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" 0 - o DATE: 7/11/2022 SCALE: SHEET: A4.0 CD }o Z Q 00 �inQmrn �0 cc: Q Z n LU 0 r'j ULn� �k Ln Equipped with smoke o detectors and a fire extinguisher. E r,- M �V No fire doors, fire partitions, REQUIRED FIRE EXIT: 1 or pull stations. °'Ln EXITS PROVIDED: 2 0 -0 � OCCUPANCY: 13 Egress lighting specs included in Lighting Smoke Detector Summary documents. 0 , 0 E �EXIT L J 5D � E E E y_•� 3 0 o Fire Extinguisher m LL X Q Smoke Detector 5° 07 w Z W � � � ❑ ® � � e Electrical Panel � J LL. d RECEIVED W2436R W2436R 436L 1IQ436L S [EXIT] J u l 11 2022 CITY DEVELOPMENT SERVICES DE ARTMENT O CD O co V M J J In Q FIRE SAFETY PLAN Q o Q SCALE: 1 /4" = 1'-0" N Lu Ln 0 L2 w R�o —w DATE: 7/11/2022 SCALE: 1/8" = 1'-0" SHEET: A5.0