FIR2023-0113+Site_Plan+11.20.2023_10.37.26_AM+3910013SYMBOL LEGEND
VICINITY MAP
GENERAL NOTES
LEGAL DESCRIPTION
CONTACTS
OW U
Z
W
m
O
1
1.
IT IS THE INTENT OFTHE CONTRACT DOCUMENTS THAT ALL WORK COMPLY
CITY OF EDMONCIS BLOCK 120
D-00 - W 24.73 FT OF LOT 39
OWNER:
K
W a
=
g a
A+
P�
WITH THE 2018 INTERNATIONAL BUILDING CODE, 2018 WASH INGTON ENERGY
LESS N 40 FT AND LOT 40 LESS N 40 FT
RED TWIG EDMONDS LLC
COLUMN GRID INDICATORS
40
CODE, AND OTHERAPPLICABLE CODES, RULES, AND REGULATIONS OF
SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF
117 5TH AVE S
JURISDICTIONS HAVING AUTHORITY.
WASHINGTON.
EDMONDS, WA98020
ku)
2.
PRIOR TO COMMENCEMENT OFANY PORTION OFTHE WORK, THE CONTRACTOR
Lo
SHALL NOTIFYTHE ARCHITECT OFANY DISCREPANCIES NOTED AMONG OR
ARCHITECT:
BETWEEN THE CONTRACT DOCUMENTS, OWNER -PROVIDED INFORMATION,
CODE SUMMARY
CAPSULE
N
✓d'''es
SITE CONDITIONS, MANUFACTURER RECOMMENDATIONS, OR CODES,
CONTACT: MIKE La FON
REGULATIONS, OR RULES OFJURISDICTIONS HAVING AUTHORITY.
BUILDING CODE:
20181NT'L BUILDING CODE
2366 EASTLAKEAVE E#403
0
v
O
NORTH INDICATOR
S` ��
Q
3.
PRIOR TO COMMENCEMENT OFANY PORTION OFTHE WORK, THE CONTRACTOR
ENERGY CODE:
2018 WASHINGTON ENERGYCODE
SEATTLE, WA98102
=
a
SHALL BECOME FAMILIAR WITH THE CONTRACT DOCUMENTS OWNER-
LAND USE CODE:
EC 17
t: 206.395.9672
cn a
"
M Main St
PROVIDED INFORMATION, AND SITE CONDITIONS, INCLUDING TAKING FIELD
ZONING:
BD1
e: mike@capsule-space.net
� a
0—
v
1
_
M EASU REM ENTS AS NECESSARY.
OVERLAYS:
ENV. CRITICALAREAS
N/A
N/A
� <
a
�Q
SITE
4.
THE CONTRACTOR SHALL SECUREAND PAY FOR ALL GOVERNMENTAL PERMITS,
ENGINEER:
A1.01
BUILDING ELEVATION INDICATOR
FEES, LICENSES, AND INSPECTIONS NECESSARY FOR PROPER EXECUTION AND
HEIGHT LIMIT:
30'
HARRIOTT VALENTINE ENGINEERS
1n
v
COMPLETION OFTHE WORK, EXCEPT FOR THE GENERAL BUILDING PERMIT.
STREET SETBACK:
0'
CONTACT: TODD VALENTINE
1
5.
THE CONTRACT DOCUMENTS ARE COMPLEMENTARYAND WHAT IS REQUIRED
BY ONE SHALL BE BINDING AS IF REQUIRED BYALL.
REAR YARD SETBACK:
SIDE YARD SETBACKS:
0
0'
1932 FIRSTAVENUE #720
SEATTLE,WA 98101
4
A1.01
2
INTERIOR ELEVATION INDICATOR
Dayton st
Dayton St
6.
REPETITIVE FEATURES NOT INDICATED IN THE DRAWINGS EVERYWHERE THAT
PARKING REQUIREMENTS:
0 IN DOWNTOWN RETAIL CORE
t: 206.624.4760
<
THEY OCCUR SHALL BE PROVIDED AS IF DRAWN IN FULL.
e: tvalentine@harriottvalentine.com
3
`4)
7.
ALL DIMENSIONSARETO FACE OF FRAMING OR FACE OF CONCRETE, UNLESS
>
OTHERWISENOTED. CONTACT ARCHITECT FOR CLARIFICATIONS.
SNOHOMISH CO. PARCEL NUMBER
CONTRACTOR:
SECTION _
r L
8.
DO NOT SCALE THE DRAWINGS.
KASPER CONSTRUCTION
1 -A1.01
BUILDING SECTION INDICATOR
#00434212003900
CONTACT: JAMES KASPER
10625 FALK RD NE
=
BAINBRIDGE ISLAND, WA98110
1
Maple St
A1.01
DETAIL INDICATOR
N
e: kasperstairs@gmaiL.com rs@gmail.com
+100.00'
SPOT ELEVATION
Alder St
O
z
+100.00'
LEVEL DATUM
TENT PERMIT CONDITIONS
INSULATED STUD WALL
1.
OCCUPANT LOAD SHALL COMPLY WITH STATE REGULATIONS.
0
UNINSULATED STUD WALL
2.
DOORS AND DOOR HARDWARE SHALL COMPLYWITH IBC CHAPTER 10.
CONCRETE WALL
3.
CONCRETE BALLAST BLOCKS SHALL BE LOCATED SA AS TO SAFELY DISTRIBUTE WEIGHT ON EXISTING DECK STRUCTURE,
OR OTHER
NEW WALL
LOCATIONS AS APPROVED.
cn z o
w
4.
TENT STRUCTURE IS NOT TO BE OCCUPIED DURING HEAVY SNOW EVENTS.
a < U
� o
DEMOLISHED WALL
5.
TENT STRUCTURE IS NOT TO BE OCCUPIED DURING HIGH WIND EVENTS.
U-) o =
z
6.
THIS PERMIT IS TEMORARY AND TENT STRUCTURE MUST BE REMOVED NO LATER THAN 180 DAYS FROM ISSUANCE.
m
ROOM NAME
7.
PRE-OCCUPAN CYINSPECTI0NS BY FIREAND BUILDING INSPECTOR REQUIRED.
"'
o
101
ROOM IDENTIFIER
8.
POST -REMOVAL INSPECTION BY BUILDING INSPECTOR IS REQUIRED.
a76
9.
INSTALLATION, USE AND MAINTENANCE OF EQUIPMENTAND COMPONENTS SHALL BE PER MANUFACTURER'S SPECIFICATION,
76
E E
oN CN
101
DOOR IDENTIFIER
INSTALLATION INSTRUCTIONS, AND APPLICABLE STATE CODES.
LJJ
o
N `N
It
WINDOW IDENTIFIER
10.
HEATING EQUIPMENT MUST BE A PPROVED BY FIRE MARSHALL.
SG E
JEGRESS
INDICATOR
30"x24" FOUR TOP
Q
SAFETY GLASS INDICATOR
W1
WALLTYPE IDENTIFIER
❑
❑
(ZIREVISION
m
INDICATOR CLOUD
36"06" FOUR TOP
u')
DS
1-6
S 90000'00" E _ 71.75'
Fol
DOWNSPOUT
3411~
o
W
SD
SMOKE DETECTOR
Ln
g
COMBINATION SMOKE &
0
CARBON MONOXIDE DETECTOR
EXIST. BLDG - NO CHANGE
EXHAUSTFAN
a
It�t
SITE NOTES
1. SITE INFORMATION CONTAINED HEREIN,
INCLUDING BUT NOT LIMITED TO,
TOPOGRAPHIC ELEVATIONS, DIMENSIONS
AND LOCATIONS OF EXISTING UTILITIES, IS
BASED ON CITY OF EDMONDS DATA, AND IS
PROVIDED FOR INFORMATIONAL PURPOSES
ONLY. THE ARCHITECTTAKES NO
RESPONSIBILITY FOR ITSACCURACY.
2. CONTRACTOR SHALLVERIFY LOCATION OF
ALL EXISTING UTILITIES. CARE SHOULD BE
TAKEN TO AVOID DAMAGETO OR
DISTURBANCE OF EXISTING UTILITIES.
3. NO SEDIMENTSHALL BE TRACKED ONTO THE
STREET OR ONTO PAVED SURFACES.
SEDIMENT SHALL BE REMOVED FROM
TRUCKSAND EQUIPMENT PRIOR TO LEAVING
THE SITE. IN THE EVENT OF FAILURE OFTHE
EROSION CONTROLSYSTEM RESULTING IN
SEDIMENT BEINGTRACKED ONTO PAVED
SURFACES, THE CONTRACTOR SHALL
IMMEDIATELY IMPLEMENT MEASURES TO
CORRECT THE SITUATION, AND STREET
SWEEPING SHALL BE EMPLOYED ON AN
EMERGENCY BASIS. IF STREET SWEEPING
VEHICLES ARE UTILIZED, THEY SHALL BE OF
THE TYPE THAT ACTUALLY REMOVES THE
SEDIMENT FROM THE PAVEMENT.
4. ALL EARTH SURFACES EXPOSED BY WORK
PERFORMED SHALL BE LANDSCAPED WITH
SUITABLE VEGETATION TO PREVENT EROSION
FOR THE PERMANENT CONDITION.
5. ALLTEMPORARY CUTS MUST BE NO STEEPER
THAN 1-1/2HTO 1VIN FILLAND MEDIUM
STIFF COLLUVIUM AND NO STEEPER THAN
1 H:1V IN UNDERLYING STIFFTO HARD
GLACIAL DEPOSITS.
6. NO ENCROACHMENT ISALLOWED ON
ADJACENT PROPERTY, INCLUDING WORK FOR
TEMPORARY EXCAVATIONS, LANDSCAPING,
OR RETAINING WALL CONSTRUCTION.
1 SITE PLAN
I 1 /8" = 1 1-0"
RADIANT -TYPE
ELECTRIC PATIO HEATER
RADIANT -TYPE
ELECTRIC PATIO HEATER
r) SEATING PLAN
L1/2"=l'_011
L -ju. J I L I LIV I I 1\F M1 r LI\ I II I\
BALLAST EA. W/ MIN. 40 LB. WEIGHT, TYP.
TENT ENTRY
Cp
U O
N
06 00
CD
o Q
E -0
M c
au o
o m E
E �w
a., _
>' cn
a)
o Q
E _0 Ln
(D (D l�
m
m 00-0
z
O
Q
w �
w
c-D l-- O
z O w
�zz
z Q w
Q w Q c�
cn rz w
wzw
zo
cn l-- c-D lZ