REVIEWED BLD2021-0683+Manufacturer_Specifications_and_Installation_Instructions+5.17.2021_2.35.38_PM+2200931Job Name: . TR E® Unit Prepared YHC074F3RMAIX 0 Quantity: 1 Trane Precedent Gas/Electric Packaged Rooftop Application Unit Size �Cpply Fan IMENEVII = External � DX cooling, 6 Ton Dual Airflow Static Height gas heat compressor Pressure 2400 cfm 0.500 in H2O 3.91 ft Unit Features Fresh Air Selection Without fresh air selection SupplyFan/Drive/ MotorType Multi speed fan Panels/Filters Standard condenser coil Unit Electrical ge/phase/hertz 208-230/60/3 MCA 38.20 A MOP 50.00 A imensions m. Weight Width Length Minimum Maximum 4.44 ft 7.39 ft 1016.0 lb 639 kg • • Unit Controls Microprocessor controls 3ph Communications Option Without communications System Monitoring Controls 1 Without system monitoring controls System Monitoring Controls 2 No monitoring controls Entering Dry Bulb 80.00 F Entering Wet Bulb 67.00 F Ambient Temp 95.00 F Leaving Coil Dry Bulb 57.35 F Leaving Coil Wet Bulb 57.09 F Leaving Unit Dry Bulb 58.26 F Leaving Unit Wet Bulb 57.44 F Refrigeration System Options i Leaving Dew Point 56.92 F Heat Type Gas Heat Heating Stages 1 Output Heating Capacity 97.20 MBh Output Heating Capacity with Fan 98.52 MBh Heating EAT 70.00 F Heating LAT 107.80 F Heating Temp Rise 37.80 F Capacity Gross Total 73.60 MBh Gross Sensible 58.70 MBh Net Total 72.28 MBh Net Sensible 57.38 MBh Fan Motor Heat 1.32 MBh EER IEER/SEER 13.1 EER 16.00 2017-09-18 15:17:53Z Page 1 of 9 Job Name: . TR E® Unit Prepared YHC074F3RMAIX 0 Quantity: 1 Indoor Fan Data Drive Type Variable Direct Indoor Fan Performance Airflow 2400 cfm r Design ESP 0.500 in H2O Indoor Motor Operating Power 0.51 bhp Indoor Motor Power 0.38 kW Indoor RPM 916 rpm Indoor Fan FLA 2.40 A Power 4.51 kW Circuit 1 RLA 6.80 A Circuit 2 RLA 3.50 A Outdoor Fan Data Type Propeller Fan Quantity 1 Drive Type Direct Outdoor Fan Performance Outdoor Motor Power 0.52 kW Condenser Fan FLA 2.40 A Exhaust Fan Data Type FC Centrifugal Drive Type Direct Exhaust Fan Performance Exhaust Fan FLA 8.50 A 2017-09-18 15:17:53Z Page 2 of 9 Job Name: . TRAIVE® Unit Prepared YHC074F3RMAlX Quantity: 1 EVAPORATOR SECTION ACCESS PANEL CONDENSATE DRAIN (ALT) 3/4"-14 NPT DIA. HOLE — 4 PANEL CONDENSER FAN ONDENSER COIL Y7 y8• NR CONTROL WIRE 7/8" DIA HOLE e ERVICE GAUGE PORTACCESS 1 3/8'DIA HOLE 47 7/8` 1 UNIT POWER WIRE 12' NPT GAS CONNECTION � (BOM BH 8120M B H ) 3/4' NPT GAS CONNECTION 050MBM, 200MOH 6 250MBH) CON"T'ROLAND COMPRESSOR ACCESS PANEL PACKAGED GAS / ELECTRICAL THROUGH THE ISOMETRIC VIEW BASE CONDENSATE 11B' 27 5/8' NOTES: 1.THRU -THE -BASE ELECTRICALIS NOT STANDARD ON ALL UNITS. 2. VER IFYALL DIM EN SION S WITH INSTALLER DOCUMENTS BEFORE INSTALLATION. I I I I I I I I I I I I I I I I I 33" 1 I 3218" SUPPLY I I lI RETURN 17 12' 9 7/8' 17 12' PLAN VIEW UNIT DIMENSION DRAWING 1 RETURN 2.1(m- SUPPL L 4 aii 32 1 /4' 1 3/1" 19 1/4" 9 3/8" 16 3/4" 3 7/8' CONDENSATE 5/8' 46 718 24 12• 9 5/8" 5 5B" 4 1/4' 5 5/8" 7 5/8' PACKAGED GAS / ELECTRICAL 53 1/4 0 0 DIMENSION DRAWING HORIZONTAL AIR FLOW 2017-09-18 15:17:53Z Page 3 of 9 DIMENSION DRAWING HORIZONTAL AIR FLOW 2017-09-18 15:17:53Z Page 3 of 9 0 TRIIIYE Job Name: . Prepared By: . Unit Tag: YHC074F3RMAlX Quantity: 1 �0� 3/4'44DIAH0LE CONDENSATE DRAIN SUPPLY RETURN 27 5/8' 4 3/4' ISOMETRIC -PACKAGED COOLING 2017-09-18 15:17:53Z Page 4 of 9 Job Name: . TRAN6® Unit Prepared YHC074F3RMA1X Quantity: 1 ELECTRICAL / GENERAL DATA 12X4)(e) GENERAL HEATING PERFORMANCE Model YHC074F Oversized Motor HEATING -GENERALDATA Unit Operating Voltage. 187-253 61 CA. Unit Primary Voltage 208 I.IFS. Heating 6lodel Medium Unit Secondary Voltage 230 LI CB Heating Input (BTU) 120,000 Unit H ertz. 60 H eating Output (BTU ). 97.200 Unit Phase. 3 No Burners. 3 No Stages 1 EER Standard Motor Field Installed Oversized 61 otor Gas Inlet Pressure 1.1C A. 374 1.1C A Natural Gas (MiNM 11 4.5/14.0 MFS. 500 MFS LP 11d in Al ax) 11.0/14.0 IdC B 50 0 1.1C8 Gas Pipe Connection Size: 1/2' INDOOR MOTOR Standard 1.1 otor Oversized Motor Field Installed Oversized Motor Number 1 Number Number. Horsepower 3 8 Horsepower Horsepower: Motor Speed ( RPLI ). _ Motor Speed(RPM i. Motor Speed (RPM I, Phase 3 Phase Phase Full Load Amps: 8,5 Full Load Amps. Full Load Amps Locked RotorAmps _ Locked Rotor Amps. Locked Rotor Amps: COMPRESSOR Circut 1R OUTDOOR MOTOR Number 1 Number 1 Horsepower 5.0/2.3 Horsepower: 0.7 Phase 3 6lotorSpeed (RPM): 1100 Rated Load Amps 14.617.1 Phase. I Locked Rotor Amps 83.0/55.0 Full Load Amps. 3.5 Locked RotorAmps 109 POWER EXHAUST ACCESSORY FILTERS REFRIGERANT i2' iF ie lei Installed Power E xh aust) Type R-410 Phase. Type, Throwaway Horsepower Furnished. Yes Factory Charge Motor Speed(R PM) Number 4 Crcuit$1 `_81b Full Load Amps Recommended 20'x2"x2' Circuit*2 41 to Locked Rotor Amps R610 1 61 aximum (HACR ) Circuit Breaker sizing is br installations in the United States only 2 Refrigerant charge is an approxm ate value For a more pre ase value, see unit nameplate and sery ice instructions. 3 Value does not ncludePower Exhaust Accessory 4 Value includes oversized motor 5 Value does not include Power E xhaust Accessory 6. E E R is rated at AH RI conditions and in accordance with DOE test procedures 2017-09-18 15:17:53Z Page 5 of 9 Job Name: . TR E® Unit Prepared YHC074F3RMAIX 0 Quantity: 1 PACKAGED GAS / ELECTRICAL CORNER WEIGHT \O A INSTALLED ACCESSORIES NET WEIGHT DATA ACCE SSORY E IGH—S ECONOMIZER 1.1OTORIZED OUTSIDE AIR DAMPER I.IANUAl- OUTSIDE AIR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST THROUGHTTHE BASE ELECTRICAL/GAS.FIOPS UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS iFIOPS1 HAIL GUARD SMOKE DETECTOR, SUPPLY/ RETURN NOVAR CONTROL STAINLESS STEEL HEAT EXCHANGER REHEAT ROOFCURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET AO 33a 01b CO 2s801b EI LEN GH7 (F)WID7H 1114.0 b 1016.0 Ib BO 23LO Ib O 202 O Ib s t 23' OTE: All weights are a ppro w m a to Weights for options that are not list refer to Installation guide The actual walght are listed on the unit nameplate Ion guide for weights before scheduling transportation and Installation olcal unit operating veight for the configuration sekrted Estimated nenslon with installer documents before Installation Ition only �ssones should be added to unit velght Men ordering factory or field PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY 2017-09-18 15:17:53Z Page 6 of 9 Job Name: . TR E® Unit Prepared YHC074F3RMAlX 0 Quantity: 1 CLEARANCE 36" DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" ROOF OPENING UNIT OUTLINE — PACKAGED GAS/ELECTRIC CLEARANCE 46- 88 558' PACKAGED GAS/ELECTRIC DOWN FLOW TYPICALROOF OPENING CLEARANCE FROM TOP OF UNIT 72' CLEARANCE48" CLEARANCE 36" 46- 53 1/4' 2017-09-18 15:17:53Z Page 7 of 9 Aft Job Name: . TJMME® Unit Prepared YHC074F3RMA1X W Quantity: 1 Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather -resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM 13117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil - faced, fire -retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil -faced, closed -cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double -hemmed and gasket -sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2-inch MERV 8 and MERV 13 filters shall also be available. Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHC074F, T/YHC092F,T/YHC102F, 120F). Plenum fan design shall include a backward -curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors. All 6 to 8'/2 ton units (standard efficiency) shall have belt drive motors with an adjustable idler -arm assembly for quick -adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons, 6 ton (074), 7'/2 to 81/2 (high efficiency) units have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Outdoor Fans The outdoor fan shall be direct -drive, statically and dynamically balanced, draw -through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Multi -Speed Indoor Fan System Multi -speed indoor fan system is designed for use in applications for meeting the minimum requirement of CA Title 24. This system incorporates a multi -speed fan control to change the speed of the fan to 67% of full airflow based off of compressor stages. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard for all 3 to 10 ton standard efficiency models and 4, 5, 6, 7.5, 8.5 ton high efficiency models. The microchannel type condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube -to -fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all -aluminum microchannel coils also help to reduce the unit weight. These all aluminum coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils 2017-09-18 15:17:53Z Page 8 of 9 Aft Job Name: . TJMME® Unit Prepared YHC074F3RMA1X V Quantity: 1 shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A plastic, dual -sloped, removable and reversible condensate drain pan with through -the -base condensate drain is standard. High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory -installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field -installed kit) and also comply with the California requirement for low NOx emissions (Gas/Electric Only). Human Interface The Human Interface shall have a 5 inch color touchscreen display that conforms to FCC Part 15 Class B with an Ingress Protection Rating of IP24.The display text shall be readable by a person with 20/20 vision at a distance of 3 feet and 600 angle at lighting levels ranging from 100 lux - 25,000 lux. Also, the display shall operate at temperatures of -400 C to 70" C. Firmware and unit configurations shall be able to be restored via a USB storage device. 2017-09-18 15:17:53Z Page 9 of 9