APPROVED PLN BLD ENG BLD2022-0947+Arch & SITE_Plan+7.17.2022_9.45.36_AM+2994192PROJECT INFORMATION Owner and address: Megan McMurry 740 Hemlock St. Edmonds, WA 98020 Parcel I D#: 00484500701200 Neighborhood 1605001 NW1/4 SEC25 T27N R3E PROJECT DESCRIPTION Demo existing deck and build new 494 SF 2nd story composite deck with 36" guard rail. Zone RS-6 Corner NO Flag NO Setbacks: Required Actual Front 20 20 Sides 5 5 Rear 15 11 Other Height CODES AND DESIGN LiVE LOADS Ai methods. materials and workmanship shall conform to the 2018 International Building Cod,-. i iE3C} as amended and adopted by the local Building Department. Snow load- 25 psf Deck live load. 60 psf Seismic Criteria. Assumed Soil Site Class D, Seismic Design Category D. Sds = i2 859; 1 = 1 C FOUNDATION AND SOIL PRESSURE Presumptive vertical foundation pressure, 1.500 psf. STRUCTURAL REINFORCED CONCRETE All concrete shall meet the requirements of ACI-301, "Specifications For Structurai Concrete For Buildings." Place concrete per ACI-304 and conform to ACI-306R for cold weather placement and ACI-305R for hot weather placement. Protect all concrete from premature drying excessive hot or cold temperature. All concrete thicker or deeper than 4 inches shall be vibrated during placement, Use internal mechanical vibrators. Inserts, bolts. boxes, pipes.. conduits; and other accessories shall be securely installed and inspected prior to placing concrete. Remove water, debris tv°Ood, and loose -_�ncreyte from space where concrete is to be placed. 000 psi minimum at 28 days, 5'A sank minimum mix (special inspection is not required Si . i p . 5 inches maximum water / cement 0 47 maximum by weight air, entrainment. 5% +/- 1 % 3-4-inch maximum size aggregate Cement: ASTM C 150, normal — Type i or ASTM C595, Type IL Coarse and fine aggregate: ASTM C33 Water shall be clean and not detrimental to concrete. Admixtures containing chlorides shall be used. Do not use calcium chloride, fly ash and related materials Reinforcing steel shall conform to ASTM A615 Grade 60 new billet stock, deformed steel free of FtJst, scale or other bond -reducing coatings. Tie bars securely with #16 double annealed wire_ . WOOD FRAMING AND LUMBER GRADING Allowable stress required shall be in accordance with standard grading rules of West Coast L_,ar-,,ber No. 16. Moisture content shall be maximum 19%. Wood framing details, not shown otherwise, shall be constructed to the minimum standards of tl ,e IBC and shall conform to Table 2304.10.1 Fastening Schedule of the iBC. Notations on drawings regarding connectors refer to products by the Simpson Strong Tie Company, Catalog C-C-20: V1here preservative treated lumber is cut or drilled after treatment, the cut surface shall be field i Bated with approved preservative ; by repeated brushing, dipping or soaking until the wood adsorbs no more preservative. 8d common nail . Shank diameter = 0.131 inches minimum 1 Old common nail : Shank diameter = 0.148 inches minimum Galvanized nails shall be hot -dipped or tumbled. M!nimum nail penetration in framing = 1 1/2 inches Ali fasteners and connectors exposed to the elements or in contact with preservative treate-ri Material shall be hot dip galvanized. SECTIONS AND DETAILS Sections and details showing reinforcing. bolts. framing members. and connections are intendecl to illustrate specific detail No attempt has been made to show all elements passing through a specific section or detail. Construction details not specifically shown on the drawings shall follov- similar details or sections of this project as approved by the SER. I `Y I I I I I OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. LOT COVERAGE CALCULATIONS: Lot Area: 11,040 sf Structures: House 2,113 sf 2,113 sf/11,040 sf = 19% Coverage Imoervious surfaces: Driveway 2,165 sf House 2,113 sf Patio 120 sf Deck _ 218 sf 4,616 sf 4,616 sf/11,040 sf=42% Coverage NN OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE ALL DISTURBED SOILS SHALL BE COMPOST AMENDED PER CITY OF EDMONDS STANDARD DETAIL SD-642 OR APPROVED EQUAL. Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. l 19 1/1 0 �7O C) IL0,5 \0 I taz Z_ 50' F,r-,\zv,e_A ENGINEERING DIVISION APPROVED AS NOTED 08/01/2022 NO STORMWATER MANAGEMENT SYSTEM REQUIRED AT THIS TIME. IF NEW AND/OR REPLACED IMPERVIOUS SURFACE EQUALS 2000SQFT OR GREATER, A STORMWATER MANAGMEMENT SYSTEM MAY BE REQUIRED PER CITY CODES AND STANDARDS 34rk o " qy 12-1 �cr(Pz �� S} CCs �, i _-X \ 2 \ e-Age(- E ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE APPROVED BY PLANNING Aug 03 2022 City Of Edmonds Building Department ------------- Work ``RRn�---------- Address X4ZQV K ST Owner � Approved Date o� P v � SNP Building Official Er v ------------------ Permit Number `AAs? _.�4022-0947 ---------------------------- TTZ e- 6 l o co-V t o► 5 t,r,, t 9'/-2 t 23,) RECEIVED Jul 19 2022 CITY OF EDMONDS DEVELOPMENT SERVICES _I DEPARTMENT t WERKn s t , EXZhK vUo Wall OP t:NVaaE "NG0*A -- — ac,Mb - , aq atlew ur oae can 4— �— Soagar YNf"ats m : rows W. — � - >w•mn L /-I3'rren -�� 'aManeaWt>s rMK'adx 4Munn, etpe d,.rarti. lm � It?• a aq tan+n >7 ,sad o- It Out Watma 1. rfducw 1. aoeualum +cn+ss 9se Iha, or b9 as 60 aNv1 2a8 nurJacs,,rere Isvn.cw if,Aele, Mdae. m 2.6 bend Ruse 111' n Guards 6 Attachment Guards are required when the deck re more Then 30 ,oche* above grade I 2.2 UI.Sty, typ" j- 6'A' max. s0errq - - 2.6 0, 514 board ad cap- attach f f r_ ar to guard poet wM (31 012 by 3• - *sews uv,g (3) Me thft. wd {�-�� ab MM 0 14a --I 'i tlamoter 2.41 top arld boUwn. wwt re I' guard poal .11, (2)8d mreaded 1 I nab rr i21 e8 wood W"e � y t , ; I''I r 2 tr!' wny an Ineae lace 11 a.a guard poet rypral 00 Not Nolyh }} f r•' 2 a 8 —W rm a olawdo L -2 541• diamelur Lsoenj gs shell ' — attach bahAWS et lop and bo%o, won r —gh-bolls not neow the (1 t e8 1000 avow or (21 ad Poet-trame and waehws Od*sage of . 4' Uvest.0 nays wdn 0.135 oorrwu; drpmete, sphere dlamaW. A xooc+.*.oe,� i teem. s d.e...n ne wr Section A A twe a0see.Ibab Prartl �',m,or po+,n e,q„urad l know+-w, eaa• Section B fobA/" �WI,c0.rY 1 of lM Were oe 10c 6F 1eo) ;�, S r \ rt I 31� sh"NN S4" %W" Dec*vv JOltfs JOx%t HarxWs Trc Wad 2K ledger 75()o uOacKY hO+ddocW d M 4 kxaltom y ormo a" the deck stud w1thm ; e4cft end 11%s,til DW ft)an tN F01Y threaded 3M' dWmeter tat t)reCinNed w11h a —nwnum w s -n embedtnevll into SOW framing I_e,d 4�e ` vpuon ip 1 R 2' min x louts Post to Beam Connection with Knee Brace (Knee braces are required W Posts greeter than 4 feet to height. ( .I,e,.w•.. gra,�, a—psase.untors.a �- --�1i ,., nun, oo+es.c, •.,rr n,.. rer.,p C,••ow,,aas•.n �. >r .+r.,".x s... t.,.e Ql.eIn,ve•aamw,rO.ulwaorl,i- Ta aw. *raw 1,rr na'p1 r4 aNn M ( ',y r,N, wanes. fw a e+aem paar /N eaam W!, a.teq •aNs q �KJ, i t•+ drrrYna YldI00 4tr w'd ronnecWn „�_ +.,�Jllo>' I a 5 1 \ 1�a L� 3" of 1� CL RECEIVED Jul 19 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT