REVIEWED RESUB 1-BLD2023-0665+Energy_Calculations+8.29.2023_10.23.48_AM+3752676REVIEWED BY CITY OF EDMONDS 2018 Washington State Energy Code — Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family — New & Additions (effective February 1, 2021) Version 1.0' These requirements apply to all IRC building types, including detached one- and two-family dwellings and multiple single-family dwellings (townhouses). Project Information Contact Information Flores Addition J3 Architects- Neil Jorgensen 19804 81st PL W, Edmonds 98026 425-242-0369 Instructions: This single-family project will use the requirements of the Prescriptive Path below and incorporate the minimum values listed. Based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Provide all information from the following tables as building permit drawings: Table R402.1- Insulation and Fenestration Requirements by Component, Table R406.2 - Fuel Normalization Credits and 406.3 - Energy Credits. Authorized Representative KU Date 05/31/2023 i All Climate Zones (Table R402.1.1 R-Value a U-Factor a Fenestration U-Factor b n/a 0.30 Skylight U-Factor b n/a 0.50 Glazed Fenestration SHGC b,e n/a n/a Ceiling e 49 0.026 Wood Frame Wall g,h 21 int 0.056 Floor 30 0.029 Below Grade Wall `,h 10/15/21 int + TB 0.042 Slab d,f R-Value & Depth 10, 2 ft n/a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity that is less a than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. The fenestration U-factor column excludes skylights. b "10/15/21 +5TB" means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at c the interior of the basement wall. "10/15/21 +5TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB" means R-5 thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1. For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth e extends over the top plate of the exterior wall. R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall meet the requirements for thermal barriers protecting foam plastics. For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for g climate zone 5 of ICC 400. Int. (intermediate framing) denotes framing and insulation as described in Section A103.2.2 including standard h framing 16 inches on center, 78% of the wall cavity insulated and headers insulated with a minimum of R-10 insulation. RESUB Aug 29 2023 C OF EDMONDS DEVELOPMENT SERVICES EP Prescriptive Path —Single Family 2018 Washington State Energy Code-R 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of credits. To claim this credit, the building permit drawings shall specify the option selected and the maximum tested building air leakage, and show the qualifying ventilation system and its control sequence of operation. 1. Small Dwelling Unit: 3 credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. 2. Medium Dwelling Unit: o credits All dwelling units that are not included in #1 or #3 3. Large Dwelling Unit: 7 credits Dwelling units exceeding 5,000 sf of conditioned floor area 4. Additions less than 500 square feet: 1.5 credits All other additions shall meet 1-3 above Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4. Summary of Table R406.2 Heating Options Fuel Normalization Descriptions Credits - select ONE heating option User Notes 1 Combustion heating minimum NAECAb 0.0 0 2 Heat pump` 1.0 ❑ 3 Electric resistance heat only - furnace or zonal -1.0 ❑ 4 DHP with zonal electric resistance per option 3.4 0.5 ❑ 5 All other heating systems -1.0 Credits - select energy option category ❑ Energy Options p Energy Credit Option Descriptions ONE from each 1.1 Efficient Building Envelope 0.5 ❑ 1.2 Efficient Building Envelope 1.0 ❑ 1.3 Efficient Building Envelope 0.5 ❑ 1.4 Efficient Building Envelope 1.0 ❑ 1.5 Efficient Building Envelope 2.0 ❑ 1.6 Efficient Building Envelope 3.0 ❑ 1.7 Efficient Building Envelope El 0.5 ❑ 2.1 Air Leakage Control and Efficient Ventilation 0.5 ❑ 2.2 Air Leakage Control and Efficient Ventilation 1.0 ❑ 2.3 Air Leakage Control and Efficient Ventilation 1.5 ❑ 2.4 Air Leakage Control and Efficient Ventilation Li 2.0 ❑ 3. la High Efficiency HVAC 1.0 0 3.2 High Efficiency HVAC 1.0 ❑ 3.3a High Efficiency HVAC 1.5 ❑ 3.4 High Efficiency HVAC 1.5 ❑ 3.5 High Efficiency HVAC 1.5 ❑ 3.6a High Efficiency HVAC 2.0 ❑ 4.1 High Efficiency HVAC Distribution System 0.5 ❑ 4.2 High Efficiency HVAC Distribution System 1.0 ❑ Prescriptive Path - Single Family 2018 Washington State Energy Code-R 2018 Washington State Energy Code — Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family — New & Additions (effective February 1, 2021) — Summary of Table Energy Credit Option Descriptions (cont.) Efficient Water Heating Efficient Water Heating Efficient Water Heating R406.2 (cont.) Credits -select ONE energy option from each category d 0.5 ❑ 0.5 ❑ 1.0 0 Energy Options 5.1d 5.2 5.3 5.4 Efficient Water Heating 1.5 ❑ 5.5 Efficient Water Heating 2.0 ❑ 5.6 Efficient Water Heating 2.5 ❑ 6.1e Renewable Electric Energy (3 credits max) 1.0 0 7.1 Appliance Packaee 0.5 ❑ User Notes Total Credits 1 1 2.0 IlCalculate Totall I Clear Form a. An alternative heating source sized at a maximum of 0.5 W/sf (equivalent) of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. b. Equipment listed in Table C403.3.2(4) or C403.3.2(5) c. Equipment listed in Table C403.3.2(1) or C403.3.2(2) d. You cannot select more than one option from any category EXCEPT in category 5. Option 5.1 may be combined with options 5.2 through 5.6. See Table 406.3. e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max. See the complete Table R406.2 for all requirements and option descriptions. f. Use the single radiobutton in the upper right of the second column to deselect radiobuttons in that group. Please print only pages 1 through 3 of this worksheet for submission to your building official. Prescriptive Path —Single Family 2018 Washington State Energy Code-R 3 simple Heating System Size: wasnington state This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Flores Addition 19804 81st PL W Edmonds 98026 Heating System Type: O All Other Systems Contact Information Neil Jorgensen J3 Architects LLC 425 242 0369 QQ Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (AT) Edmonds ] AT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) Average Ceiling Height Instructions Average Ceiling Height (ft) Glazing and Doors Instructions Select U-Factor Skylights Instructions Insulation Attic Instructions l Select R-Value J Single Rafter or Joist Vaulted Ceilings Instructions R-38 Vented Above Grade Walls (See Figure 1) Instructions LR-21Intermediate Floors Instructions R-30 � J Below Grade Walls (see Figure 1) Instructions Select R-value J Slab Below Grade (see Figure 1) Instructions Select conditioning � Slab on Grade (see Figure 1) Instructions Select R-Value � , Location of Ducts Instructions Unconditioned Space;=::�'w Figure 1. Above Grade Below Grade 107 Conditioned Volume 7.8 829 U-Factor X Area = No selection U-Factor X Area = 0.50 U-Factor X Area = No selection U-Factor X Area 0.027 1 107 U-Factor X Area 0.056 1 22 U-Factor X Area 0.029 1 107 U-Factor X Area No selection F-Factor X Length No selection F-Factor X Length No selection Sum of UA Duct Leakage Coefficient 1.10 Envelope Heat Load Sum of UA x AT Air Leakage Heat Load Volume x 0.6 x AT x 0.018 UA UA UA M. UA 2.89 UA 1.20 UA 3.10 1U, UA UA 7.20 331 Btu / Hour 412 Btu / Hour Building Design Heat Load 743 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 817 Btu / Hour Ducts in unconditioned space: sum of buildingq heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 1,022 Btu / Hour Buildinq and duct heat loss x 1.40 for forced air furnace Buildinq and duct heat loss x 1.25 for heat pump (07101113)