Loading...
APPROVED BLD-BLD2021-0977+Architectural_Plan+7.14.2021_7.08.53_PM+2301276GENERAL NOTES S w o o2 z J V) z 0 0 o- w J W m z U) ry 0 L� 0 Y z Q E 0 to O I N O N LO w w a 0 0 J APPROVED PLANS MUST BE ON JOB SITE City of Edmonds Building Department APPROVED Plans ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE City Of Edmonds Building Department Work WINDOW ADDITION Address 9022 202ND PL SW Owner GRAHAM Approved Date 08/16/2021 Building Official Permit Number BLD2021-0977 1.0 GENERAL THE STRUCTURE HAS BEEN DESIGNED TO RESIST CODE -REQUIRED VERTICAL AND LATERAL FORCES AFTER THE CONSTRUCTION OF ALL STRUCTURAL ELEMENTS HAS BEEN COMPLETED. STABILITY OF THE STRUCTURE PRIOR TO COMPLETION IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THIS RESPONSIBILITY INCLUDES BUT IS NOT LIMITED TO JOBSITE SAFETY; ERECTION MEANS, METHODS, AND SEQUENCES; TEMPORARY SHORING, FORMWORK, AND BRACING; USE OF EQUIPMENT AND CONSTRUCTION PROCEDURES. CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO STARTING WORK. THE ENGINEER IS TO BE NOTIFIED OF ANY DISCREPANCIES. CHANGES, OMISSIONS, OR SUBSTITUTIONS ARE NOT PERMITTED WITHOUT WRITTEN APPROVAL OF THE ENGINEER. ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 2018 EXISTING INTERNATIONAL BUILDING CODE (IBC) AND/OR 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) AS AMENDED AND ADOPTED BY THE LOCAL BUILDING OFFICIAL OR APPLICABLE JURISDICTION. 2.0 DESIGN CRITERIA A. VERTICAL LOADS 1. LIVE LOADS ROOF (SNOW) Is = 1.0 25 PSF FLOORS (RESIDENTIAL) 40 PSF 2. DEAD LOADS ROOF 15 PSF FLOORS (RESIDENTIAL) 12 PSF B. LATERAL LOADS: LATERAL FORCES ARE TRANSMITTED BY DIAPHRAGM ACTION OF THE FLOORS TO SHEAR WALLS. LOADS ARE THEN TRANSFERRED TO THE FOOTINGS, WHERE ULTIMATE DISPLACEMENT IS RESISTED BY PASSIVE PRESSURE OF EARTH AND SLIDING FRICTION OF EARTH. OVERTURNING IS RESISTED BY THE DEAD LOAD OF THE STRUCTURE. 1. WIND: EXPOSURE B BASIC WIND SPEED = 100 M.P.H. (3 SECOND GUST, ULTIMATE). IMPORTANCE FACTOR, Iw = 1.0 Kzt = 1.39 SIMPLE DIAPHRAGM BUILDING, ENCLOSED 2. SEISMIC: SEISMIC DESIGN CATEGORY = D IMPORTANCE FACTOR, IE = 1.0 OCCUPANCY CATEGORY II MAPPED SPECTRAL RESPONSE COEFFICIENTS, Ss=1.29 AND S1=0.455 SPECTRAL RESPONSE COEFFICIENTS, SDs=1.032 AND SD1=0.571 RESPONSE MODIFICATION FACTOR R=6.5 SEISMIC RESPONSE COEFFICIENT Cs=0.159 (ULTIMATE STRENGTH) C. FOUNDATION DESIGN CRITERIA:: FOUNDATION DESIGN CRITERIA: SOIL BEARING PRESSURE: 1500 PSF (ASSUMED) ITS THE CONTRACTORS RESPONSIBILITY TO VERIFY THAT THE SITE SOILS PROVIDE THE MINIMUM BEARING CAPACITY. ALL FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH OR COMPACTED "STRUCTURAL BACKFILL". AREAS OVER -EXCAVATED SHALL BE BACKFILLED WITH "STRUCTURAL BACKFILL". 3.0 FOUNDATION CONCRETE: SHALL BE MADE WITH PORTLAND CEMENT ASTM C-150 TYPE II OR TYPE I AND SHALL BE READY -MIXED PER ASTM C-94. MINIMUM CONCRETE STRENGTH SHALL BE F'C = 2500 PSI UNLESS OTHERWISE NOTED. AT VERTICAL AND HORIZONTAL EXPOSED SURFACES, MINIMUM CONCRETE STRENGTH SHALL BE F'C = 3000PSI AND SHALL CONTAIN A MINIMUM OF 5% AIR ENTRAINMENT TO A MAXIMUM OF 7% FOR DURABILITY PURPOSES ONLY. SPECIAL INSPECTION OF THE CONCRETE IS NOT REQUIRED PER 2018 IBC 1705.3 METAL REINFORCEMENT: REINFORCING SHALL CONFORM TO ASTM A-615, GRADE 60 SPLICES SHALL BE 24 BAR DIAMETERS OR 18" MINIMUM UNLESS NOTED OTHERWISE ON DETAILS. PROVIDE CORNER BARS FOR ALL HORIZONTAL BARS IN FOOTING AND WALLS. FOUNDATION PLATE OR SILL BOLTING SHALL BE PER IBC CHAPTER 23. ALL FOUNDATION PLATES OR SILLS SHALL BE BOLTED TO CONCRETE OR MASONRY WITH MINIMUM 1/2" NOMINAL DIAMETER ANCHOR BOLTS EMBEDDED AT LEAST 7" AND SPACED NOT MORE THAN 6 FEET APART. THERE SHALL BE A MINIMUM OF TWO BOLTS PER PIECE WITH ONE BOLT LOCATED NOT MORE THAN 12 INCHES OR LESS THAN 4 INCHES FROM EACH END OF EACH PIECE. 3" x 3" x 0.229" WASHERS ARE REQUIRED AT ALL ANCHOR BOLTS PER AF&PA SDPWS-2015 SECTION 4.3.6.4.3 THE PLATE WASHER ARE PERMITTED TO HAVE A DIAGONAL SLOT WITH A CUT WASHER PER IBC 2308.3.2. FOR SHEAR WALL TYPES W3 AND GREATER THE PLATE WASHER MUST EXTEND TO WITHIN 1/2" OF THE EDGE OF THE BOTTOM PLATE ON SIDES) WITH SHEATHING. WHERE ANCHOR BOLTS ARE MISSED, USE SIMPSON TITEN HD ANCHOR SAME DIAMETER AND SPACING AS SHOWN ON S1.0 AND 4" MIN EMBEDMENT INTO CONCRETE WITH 1/4"x3"x3" WASHER. OPTIONAL TO USE SIMPSON SET-XP EPDXY WITH THREADED ANCHOR BOLT AND SAME DIAMETER AND SPACING AS SHOWN ON S1.0, 4" MIM EMBEDMENT. INSTALL SIMPSON PRODUCTS PER MFR RECOMMENDATIONS. WHERE REQUIRED PER IRC R406.1, FOUNDATION WALLS SHALL BE DAMP PROFFED AROUND THE ENTIRE PERIMETER USING A METHOD THAT IS APPROVED BY THE BUILDING DEPARTMENT. ANCHOR BOLTS, BARS, AND RODS ARE TO CONFORM TO ASTM A307, CARBON STEEL BOLTS, STUDS, & THREADED ROD 60000 PSI TENSILE STRENGTH". CAST -IN -PLACE COLD -FORM STEEL CONNECTORS IN CONCRETE FOR LIGHT FRAME CONSTRUCTION ARE TO BE SIMPSON STRONG -TIE AS SPECIFIED IN THE CURRENT SIMPSON STRONG -TIE ICC ES REPORT. CAST -IN -PLACE ANCHOR BOLTS ARE TO BE 'SB' AND 'SSTB' BY SIMPSON STRONG -TIE AS SPECIFIED IN THE CURRENT CATALOG AND ICC REPORT. CONCRETE COVER OVER REBAR FOR CONCRETE CAST AGAINST EARTH AND EXPOSED TO EARTH IS 3 INCHES AND 2 INCHES FOR CONCRETE CAST IN FORMS AND EXPOSED TO EARTH, WEATHER, OR BASEMENT INTERIOR. PROVIDE APPROPRIATE BLOCK -OUTS IN FOOTINGS OR WALLS FOR PLUMBING AND ELECTRICAL STUB -OUTS. RECEIVED Jul 16 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 4.0 CARPENTRY ALL 2x FRAMING LUMBER SHALL BE STUD GRADE HEM -FIR FOR STUDS AND STANDARD OR BETTER FOR PLATES UNLESS OTHERWISE NOTED ON THE DRAWINGS OR BELOW. ALL 2" LUMBER SHALL BE KILN DRIED (KD) OR SURFACE DRIED (SD). EACH PIECE OF LUMBER SHALL BEAR THE STAMP OF THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB) OR WESTERN WOOD PRODUCTS ASSOCIATION (WWPA) SHOWING GRADE MARK OR APPROVED EQUAL. OTHER MATERIALS SHALL BE AS SHOWN BELOW: MEMBER SPECIES 6x BEAMS & HEADERS #2 HEM FIR 2x & 4x JOISTS, PURLINS & HEADERS #2 HEM FIR 6x POSTS & COLUMNS #2 HEM FIR 4x COLUMNS #2 HEM FIR 2x STUDS STUD GRADE HEM FIR MINIMUM FASTENING SCHEDULE FOR CONSTRUCTION SHALL BE PER IRC TABLE R602.3 (1) UNLESS SPECIFIED OTHERWISE BY THE ENGINEER OF RECORD. SEE STRUCTURAL DETAILS FOR REQUIREMENTS. PLYWOOD/OSB SHEATHING: EACH SHEET SHALL BEAR THE TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIATION. ALL GRADING AND INSTALLATION SHALL CONFORM TO MOST CURRENT VERSION OF PS2 FOR OSB. USE THICKNESS AND NAILING AS SHOWN ON THE DRAWINGS. SHEATHING SHALL HAVE EXPOSURE RATING AS APPROPRIATE PER THE CONTRACTOR'S CONSTRUCTION AND WEATHER CONDITIONS SPECIFIED BY CONTRACTOR. EXCEPT AS OTHERWISE SHOWN OR NOTED, PROVIDE 0.131" DIA P-NAILS OR 8d COMMON NAILS AT 6" ON CENTER @ SUPPORTED PANEL EDGES AND 0.131" DIA P-NAILS OR 8d COMMON NAILS AT 12" ON CENTER ON OTHER SUPPORTING MEMBERS FOR WALLS AND ROOFS. FOR FLOORS, USE THE SAME SPACING PATTERN AS STATED FOR WALLS OR ROOF EXCEPT USE 0.148" DIA P-NAILS OR 10d COMMON NAILS. NOTE: EQUIVALENT RATED PLYWOOD MAY BE USED IN LIEU OF OSB CALLED OUT. ALL THICKNESS AND GRADING SHALL CONFORM TO PS1 OR PS2. SHEATHING SHALL HAVE EXPOSURE RATING AS APPROPRIATE PER THE CONTRACTOR'S CONSTRUCTION AND WEATHER CONDITIONS SPECIFIED BY CONTRACTOR. ROOF DIAPHRAGM: 1/2" MIN OSB (MIN PANEL INDEX = 24/16), WITH 0.131" DIA P-NAILS OR 8d COMMON NAILS AT 6" O.C. AT SUPPORTED PANEL EDGES AND AT 12" O.C. AT FIELD TYPICAL UNLESS NOTED OTHERWISE ON PLAN. USE PLY -CLIPS INSTALLED PER MANUFACTURER'S GUIDELINES AND APA GUIDELINES. FLOOR DIAPHRAGM: 3/4" TONGUE AND GROOVE OSB (MIN PANEL INDEX = 32/16), WITH 0.148" DIA P-NAILS OR 10d COMMON NAILS AT 6" O.C. AT SUPPORTED PANEL EDGES AND AT 12" O.C. AT FIELD TYPICAL UNLESS NOTED OTHERWISE ON PLAN. SHEATHING SHALL BE GLUE -NAILED TO FRAMING WITH APPROVED ADHESIVE PER THE ARCHITECT. FIELD NAILING SHALL BE 6" O.C. AT ALL INTERIOR SHEARWALL LOCATIONS INSTEAD OF TYPICAL 12" O.C. SPACING. I -JOISTS: SHALL BE TJI BY WEYERHAEUSER, OR PRE -APPROVED EQUAL, AS INDICATED ON THE STRUCTURAL DRAWINGS. I -JOISTS SHALL BE MANUFACTURED IN ACCORDANCE WITH A CURRENT ICC ES REPORT AND APPROVED SHOP AND INSTALLATION DRAWINGS. MANUFACTURED BEAMS & HEADERS: SHALL BE MICROLLAM (LVL), PARALLAM (PSL), OR TIMBERSTRAND (LSL) BY WEYERHAEUSER, OR APPROVED EQUAL, AS INDICATED ON THE STRUCTURAL DRAWINGS. MEMBERS SHALL BE MANUFACTURED IN ACCORDANCE WITH A CURRENT ICC ES REPORT AND APPROVED SHOP AND INSTALLATION DRAWINGS. GLUED LAMINATED BEAMS (GLB): GLUED LAMINATED BEAMS SHALL BE PER A190.1, AMERICAN NATIONAL STANDARDS FOR STRUCTURAL GLUED LAMINATED TIMBER. USE BALANCED GRADE OF DF 24F-V4, FB-2,400 PSI, FV=240 PSI. FOR CANTILEVERED OR MULTISPAN BEAMS USE DF 24F-V8. FRAMING CONNECTORS: SHALL HAVE ICC ES APPROVAL AND BE MANUFACTURED BY SIMPSON COMPANY, OR PRE -APPROVED EQUAL. PROVIDE MAXIMUM SIZE AND QUANTITY OF NAILS OR BOLTS PER MANUFACTURER, EXCEPT AS NOTED OTHERWISE. ALL LUMBER HARDWARE THAT IS IN CONTACT WITH TREATED LUMBER IN A PROTECTED ENVIRONMENT INCLUDING BUT NOT LIMITED TO CLIPS, HANGERS, NAILS ..... (EXCEPT ANCHOR BOLTS) SHALL BE HOT DIPPED GALVANIZED. ALL LUMBER HARDWARE THAT IS IN CONTACT WITH TREATED LUMBER IN AN EXPOSED ENVIRONMENT SHALL BE STAINLESS STEEL. PRE-ENGINEERED ROOF TRUSSES: ALL PREFABRICATED WOOD ROOF AND FLOOR TRUSSES SHALL BE DESIGNED BE OR UNDER THE DIRECT SUPERVISION OF A LICENSED PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE THE STRUCTURE IS LOCATED. THE TRUSS SHOP DRAWINGS SHALL BEAR THE STAMP OF THAT ENGINEER. ALL NECESSARY BRIDGING, BLOCKING, PRE -NOTCHED PLATES, HANGERS, ETC. SHALL BE DETAILED OR SPECIFIED, AND FURNISHED BY THE MANUFACTURER. ALL PERMANENT BRACING FOR TRUSSES SHALL BE DETAILED AND DESIGNED BY THE TRUSS SUPPLIER. THE TRUSS MANUFACTURER SHALL VERIFY ALL SETBACKS, DIMENSIONS, AND BEARING POINTS PRIOR TO FABRICATION. MAXIMUM ALLOWABLE DEFLECTIONS SHALL BE AS FOLLOWS: ROOF TOTAL LOAD SPAN/240 OR 1.5" ROOF LIVE LOAD SPAN/360 OR 1" TRUSSES SHALL BE DESIGNED FOR THE SPANS AND CONDITIONS SHOWN ON THE PLANS AND SHALL BE FURNISHED AND INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S PUBLISHED SPECIFICATIONS. ADDITIONAL CONCENTRATED LOADS FROM MECHANICAL UNITS, AND MISCELLANEOUS EQUIPMENT, ETC. SHALL BE ACCOUNTED FOR/COORDINATED WITH THE SUB -CONTRACTORS, ARCHITECT AND TRUSS ENGINEER. ALTERATION OF THE TRUSS LAYOUT INDICATED ON THE PLANS MAY REQUIRE SUPPORTING STRUCTURAL AND FOUNDATION CHANGES, THEREFORE PRIOR APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER IS REQUIRED. TRUSSES SHALL NOT BE FIELD ALTERED PRIOR TO WRITTEN APPROVAL OF THE ENGINEER OF RECORD DESIGNING THE TRUSSES. 5.0 PRESERVATIVE TREATMENT A. PRESERVATIVE TREATMENTS ALL EXPOSED FRAMING LUMBER, PLYWOOD AND DECK MATERIALS SHALL BE PRESSURE TREATED PER AWPA SPECIFICATION P-5 OR OTHER APPROVED TREATMENT. ACZA PRESERVATIVE TREATMENT SHALL NOT BE PERMITTED EXCEPT WHERE HARDWARE (INCLUDING NAILS) IN CONTACT WITH THE TREATED PRODUCT IS COMPOSED ENTIRELY OF STAINLESS STEEL MATERIAL. STAINLESS STEEL HARDWARE SUBSTITUTED FOR HDG PRODUCTS SHALL MEET OR EXCEED THE STRENGTH AND PERFORMANCE OF THE SUBSTITUTED HDG PRODUCT ORIGINALLY SPECIFIED. B. GALVANIZATION OF HARDWARE (EXPOSED OR IN CONTACT WITH PRESERVATIVE TREATED WOOD) PROTECTED ENVIRONMENT ALL HARDWARE (HANGERS, NAILS, BOLTS, LAG SCREWS, FLASHING ETC BE HOT -DIP GALVANIZED (HDG) TO A MINIMUM COATING LEVEL OF G185 (1.85oz/ft2 OF ZINC) WHEN IN CONTACT WITH PRESERVATIVE TREATED WOOD CONTAINING PRODUCTS SUCH AS, BUT NOT LIMITED TO; CCA, ACQ, OR CBA. HDG PRODUCTS SHALL CONFORM TO THE FOLLOWING ASTM STANDARDS AS APPLICABLE; ASTM A653, ASTM A123, AND ASTM A153. WHEN USING STAINLESS STEEL OR HOT -DIP GALVANIZED CONNECTORS, THE CONNECTORS AND FASTENERS SHALL BE OF THE SAME MATERIAL. 2. EXPOSED ENVIRONMENT ALL HARDWARE (INCLUDING CONNECTORS) IN CONTACT WITH PRESSURE TREATED WOOD IN AN EXPOSED OR POTENTIAL TO BE EXPOSED ENVIRONMENT (HAVING POTENTIAL FOR WIND BLOWN RAIN TO REACH) SHALL BE STAINLESS STEEL. z O U D Ln z O U O LL H- O z J � z O z o w O _ LL Ln (n J Q w O z cnm LU , r, UN LL rn LL = 't 0 pcn0y U-) < 0 cm 0 7 0 "' M = -0 LO 0O N 0 30 W 1-1 c a_ QMru= ci J LnJd n � z z Z gE � 0 -w � w ~" U W z > =1� Ul a J O W z •N T W MzF W U a)ZW I -I WE rr QW (D �a �z Cc$K r1 U L aC6o J � a U N 0 N 0 W M C V � V 4 Q o N a� � N N uv%rft m �o 0 W Z C7 ow {�G0 W '< > V A 03 ,0 21009998 ISTER� �SS�ONAL 511312021 JOB NUMBER: 21.00116 SHEET 1 OF 2 sizo c� z J i) z 0 U D_ W J W m z U) o- O w O Y Z Q H E O d1 I N O N Lo W w a 0 O J 0_ W N 0 Q 0 \ r2 GENERAL CONTRACTOR TO PROVIDE SHORING UNDER ROOF FRAMING / STRUCTURE PRIOR TO REMOVAL OF EXISTING HEADERS AND SUPPORTING STUDS z O U D (E) RAFTERS &Ln CEILING FRAMING zz U O B w O o' LLI z O z O o LL w Ln (N) HEADER PER w PLAN o m 00 z OL I cn U L, (E) FLOOR JOISTS LL O� O U) 000 U cm U-) Q O 0 . 3: M i 0U) M = -0 B N O C W o o 3 c 2 Qrnru J LnJa Cross section at Door - A -A zu SCALE 1 /4"=V-0" g a� —w � a zX w cd >� LU W z �� Ul a a J �" ` � � � �m T z •N Uw ww w W O zF c; Z M U ^ w W 1(�ll w z w Q(D • �Z K U cdF r1 Ln w a�o J � ,y a U ti N 0 W M H C V � V GENERAL CONTRACTOR TO PROVIDE 4 �O o NLU SHORING UNDER FLOOR AND ROOF FRAMING / STRUCTURE PRIOR TO REMOVAL OF EXISTING HEADERS AND O N a Q SUPPORTING STUDS z N (E) ROOF FRAMING o O CID O G G W w Z � GENERAL CONTRACTOR TO VERIFY ALL DIMENSION SHOWN z o w ON PLAN Q L� LEGEND L.� 0 m L(E) DBL TOP PLATE (E) = EXISTING w � Z (N) = NEW B O FH = FULL HEIGHT It (E) WALL STUDS B = BEARING Lu c Lo FF =FLUSH FRAMED +tK (E) 1ST FLOOR JOISTS & SHEATHING 01,E N 3-IL2x7-1 2 WA' PSL 2.0E �Po (E) DOOR & WALL SEGMENT B TO BE REMOVED FOR (N) ,0 21009998 OPENING AREA OF NEW DOOR REPLACMENT°.�� ISTER� �SS�ONAL (E) CONIC STEMWALLV ADD (N)2x4 STUDS IN & FOOTING FLOOR CAVAITY TO MATCH NUMBER OF STUDS ABOVE A A 511312021 (6) STUDS MIN RECEIVED JOB NUMBER: Jul 16 2021 CITY E ^/ L 1, 00116 DEVELOPMENT SERVICES M T SERVICES DEPARTMENT Proposed Window Addition - Elevation B-B Existing Roof Framing - Partial Plan SHEET 2 OF 2 SCALE 1/4"=1'-0" SCALE 1/4"=1'-0" S2mO � 0 (N)3-1/2x7-1/2 PSL 2.0E 10'-8" (2)2x4 BRG STUDS & (4)2x4 FH STUDS EA SIDE OF OPNG