APPROVED BLD BLD2020-1140+Architectural_Plan+10.22.2020_5.12.50_PMAPPROVED
PLANS MUST BE
ON JOB SITE
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
INDEX
A0.1 SITE PLAN / PROJECT INFORMATION
A1.0 EXISTING HOUSE PLAN
A1.1 PLAN/SECTION/ENERGY/MECH
BACKYARD
PROJECT INFORMATION
PROPERTY ADDRESS: 21916 92ND AVE W,
EDMONDS, WA 98020
PARCEL NUMBER: 00373600701403
LOT AREA : 0.19 ACRES
ZONING: 111 SINGLE FAMILY RESIDENCE -
DETACHED
LEGAL DESCRIPTION: ALDERWOOD MANOR 09
BLK 007 D-03 - N 80.79 FT OF E 103.36 FT OF S
161.79FT LOT 14
ECA : STEEP SLOPE 40% / RIPARIAN / WETLANDS
YEAR BUILT: 1958
OWNER: DALE JOSHUA G/DALE JANINA S
27'
SIDEY)
FRONT YARD
/-- 9'
im
SIDEYARD
PLAN LEGEND
MM/ EXISTING HOUSE, 1,094 SF
AREA OF IMPROVEMENT, 126 SF
EXISTING DRIVEWAY
EXISTING 6' WOOD FENCE
City Of Edmonds
Building Department
Work GARAGE CONVERSION TO BATH/UTILITY
Address 21916 92ND AVE W
Owner JOSHUA DALE
------ -----------------
Approved Date 11-2-2020
Building Official Erg CtP
--------------
Permit Number BLD2020-1140
- -----------------------------------
All Smoke Detectors to be interconnected as part of this
permit.
SITE PLAN
SCALE: 3/32" = 1'-0"
PROJECT DESCRIPTION/ EXEMPTION REQUEST
INTERIOR RENOVATION OF EXISTING GARAGE INTO A
BATHROOM AND LAUNDRY/UTILITY ROOM
IWRoLyGVZ4laINX"to] :71
3835 S EDMUNDS ST
SEATTLE, WA 98118
Uj
O
j N
O
W o)
Q�
0�
CZ, cl,
N 0
z �' z
1O
(ONCY) 75;
N W
PROFFESIONAL
STAMP(IF NEEDED)
BLDG DEPT STAMP
ISSUE DATE
PERMIT 09.27.2020
RECEIVED
Oct 29 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
AOO 1
SITE PLAN
PROJ. INFO
19'-311 9' 12'
PLUS ARCHITECTURE
3835 S EDMUNDS ST
SEATTLE, WA 98118
ui
> 3� O
N
W �
C
N �
z(Dz
�O
N W
PROFFESIONAL
STAMP(IF NEEDED)
BLDG DEPT STAMP
ISSUE DATE
PERMIT 09.27.2020
RECEIVED
Oct 29 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Al 00
BUILDING PLAN
SCALE: 1 /4" = 1'-0"
OVERALL
PLAN
ER
M
ry
N
z
� r
U M
L
�z
N
LU
a
SECTION
ma
14' Provide a minimum of 100 square
4'-911 ,. 2' . inches of make-up air for the dryer.
\ SLOPE
w \
o \Cn
SHOWER
` TILE PER SPEC // VV
p \ XX SF
Q �
w \
z
J \
\ I
GL}�SS ENCLOSURE
FOR\SHOWER
3'-9"
EXISTING 2BY4 WALL
TYP, SPRAY FOAM
INSULATION TO A
MINIMUM OR R29
TILE FLOOR PER PLAN
LEVELER
VAPOR BARRIER
"' PLYWOOD
2BY4
1 "' RIGID FOAM INSULATION
EXISTING SLAB ON GRADE
2'-611 loo
2
uJ
A2.2 -
BAT OOM
TILE PE SPEC
58 SF \
\
NEW`Q OOR
3o8)9
HALF LlbHT
HDWR PER OVVNER
R
2'-3"
6
HANGING ROD/
HAMPER
0
2'-5"
J
220 U
EXISTING
TER HEATER
STACKED
WASHER/ DRYER
A
NEW VENT FROM
NEW 2BY4AALL TYP, EXISTING HEATER
NO INSULATION,
DRYWALL FOR \
WET AREAS UTILITY/ LAUNDRY
TILE PER SPEC '-----�
64 SF
--------- EXISTING
\ DOOR
NOTE: ALL EXISTING 2BY4 WALLS TO NAVE TO
BLOWN IN INSULATION W/ A MIN OF R29 PER HOUSE
WASHINGTON STATE ENERGY CODE
TYPE X GYPSUM THIS WALL
1 HOUR FIRE RATED WALL BETWEEN
BLOCKING UNDER PLATE
EXISTING SLAB ON GRADE
RIGID FOAM
2BY4 @ 12" O.C.
PLYWOOD
M
—IN
U)
_ 0�
CD w
w F___
_ LL
o ryo
w H
= O
U)
z
O
LL
Lu O
U) m
O O
a_
O m
� Q
� J
SIN Cf)
M �
ti �
LL
0
00
Hotwater tank to be
placed in a pan
draining to the
exte for
92
PLAN KEY
AIR INLET
AIR INTAKE VENT
4 SQUARE INCHES MIN
PER SRC 1507.3.4.4
O SMOKE DETECTOR
/CARBON MONOXIDE
DETECTOR TYP
CFM, 110, SWITCHED
PANASONIC WHISPER
CEILING VENT FAN
WALL TAG
MECHANICAL NOTES
NEW SPACE TO BE HEATED BY EXISTING GAS FORCED
AIR FURNACE VIA DUCTING ON NORTH WALL, SEE PLAN
NEW BATHROOM DOOR UNDERCUT FOR AIR FLOW
LIGHTING / ELECTRICAL LEGEND
SWITCH, LED, W/ DIMMER
2 GANG SOCKET
42 GANG SOCKET, 220
220
4" DIAMETER RECESSED LED CAN
LIGHT
O \ ^ / 4" DIAMETER RECESSED CAN LIGHT
VV (WET LABEL) LED
BATH BAR VANITY PER OWNER
EXHAUST FAN: PANASONIC 100
'4E F 1 CFM INTERMITTENT
NOTE:
WHF TO BE MAXIMUM 1.0 SONE, AS REQUIRED BY SRC
M1507.3.4.2'S FAN NOISE SECTION
NOTE :
1. THE NAME OF THE PROPOSED SPRAY FOAM PRODUCT,
ITS MANUFACTURER, AND ITS ESR REPORT NUMBER.
2. A COPY OF THE ICC ESR REPORT FOR THE PRODUCT
USED MUST BE PROVIDED ON THE JOB SITE FOR FIELD
INSPECTOR VERIFICATION.
3. THE APPLIED SPRAY FOAM MUST BE INSTALLED BY A
CERTIFIED INSTALLER.
DESIGN PROFESSIONAL OR BUILDER SHALL COMPLETE
AND POST AN "INSULATION CERTIFICATE FOR RESIDENTIAL
CONSTRUCTION" WITHIN T OF THE ELECTRICAL PANEL
PRIOR TO FINAL INSPECTION
NO STRUCTURAL ALTERATIONS, ALL ASSEMBLIES
BROUGHT UP TO CURRENT WASHINGTON STATE ENERGY
REQUIREMENTS
WALL R21
CEILING R49
FLOOR ON GRADE R10
WSEC COMPLIANCE
EFFICIENT BUILDING ENVELOPE 1 B 1.0 POINTS
WALL R-21 PLUS R-4
SLAB ON GRADE R-10
EFFICIENT WATER HEATING 5A 0.5 POINTS
ALL SHOWERHEAD AND KITCHEN SINK FAUCETS
INSTALLED IN THE HOUSE SHALL BE RATED AT 1.75
GPM OR LESS. ALL OTHER LAVATORY FAUCETS
SHALL BE RATED AT 1.0 GPM OR LESS
Iwlill)LyGVZ4laINX"to] :71
3835 S EDMUNDS ST
SEATTLE, WA 98118
Uj
O
j N
O
W o)
Q
C C _
z (n
CV
Z (' z
1O
Nrn �
�o
00) N W
PROFFESIONAL
STAMP(IF NEEDED)
BLDG DEPT STAMP
ISSUE DATE
PERMIT 09.27.2020
RECEIVED
Oct 29 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Al 01
PLANS
ENLARGED PLAN AND SECTION
SCALE: 1" = 1'-0"