Loading...
APPROVED PLN FIR REV1- BLD2022-0769+Site_Plan+5.10.2023_9.28.40_AM+3536012A I I I I EXISTING FENCE I X � X X I '` EXISTING Y, I 55' 6" STEALTH MONOPOLE X I X� — — — — — — — X % I � 1 EXISTING T MOBILE II �- /\\\ EQUIPMENT SHELTER I / EXISTING I / I � I BUILDING EXISTING T-MOBILE I II CABINETS I / I I / x I I PROPOSED BOLLARDS O I II __ 5' C/0, (5) TOTAL_ - - / x 20 I I — / Ck N / EXISTING PROPERTY LINE (TYP) I / x _-- m °° m / __-- io a 5, / I G GEN M I BLDG / —— — — — — — — ------ PROPOSED T—MOBILE 120/240VAC, 10, 200A � \ / AUTOMATIC TRANSFER SWITCH (ATS) MOUNTED ON IXISTING BACKBOARD (INTERCEPT INCOMING EXISTING COMMERCIAL POWER \ !@Cc euCCT A-4 MD CAI 110LACUT DI ALA PROPOSED T—MOBILE 48kW DIESEL GENERATOR AND 240 GALLON BELLY TANK ON PROPOSED 4'-0"x9'-0" CONCRETE PAD IN PROPOSED >-- 10' x 17' LEASE AREA EXISTING T-MOBILE ig (SEE SHEET A-1 FOR EQUIPMENT PLAN) PPC ra EXISTING T-MOBILE METER / A GENERAL NOTES 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, JAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITIES COMPANY OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, N WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. (THERE IS NO HANDICAP ACCESS REQUIRED). 8. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 9. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE RECEPTACLES. 10. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE, NO SIGNS WILL BE POSTED EXCEPT THOSE REQUIRED. 11. NO SIGNIFICANT NOISE, SMOKE, DUST OR ODOR WILL RESULT FROM THIS FACILITY. 12. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88). Zone -BN -- - Corner X Flag Setbacks: Required Actual Front N 20 20+ Front E 20 ; 20 Front W 20 : - : 20+ -- --. = = 15 15 Other S ------------- 25 12 Height ---- APPROVED BY PLANNING May 19 2023 Approved DFM CMy�s Burt South County Fire Date: 05/17/2023 05-17-2023 PLAN REVIEW REVISION NOTE: APPROVED, NO COMMENT DFM BURT 1 SITE PLAN S-1 SCALE:3116"=1'-0" BLD2022-0769 GRAPHIC SCALE 1 0 1 '' 4 = 16 REVISION ( IN FEET) May 10 2023 DMONDS 3/1 6 inch — 1 ft. CILOPMTY OF ETSERVI DEVELOPMENT SERVICES DEPARTMENT (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) I 011111i 0 Mobile T-MOBILE WEST LLC 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WASHINGTON 98011 SSynergy a division of advantage engineers 7543 WOODLEY AVENUE SUITE 201 VAN NUYS, CALIFORNIA 91406 SAC: SAM BUTLER T-MOBILE: ALLAN BATUSAN A&E: TRISTRAM HOKENSON SCHEDULE OF REVISIONS 6 5 4 3 04-18-2023 REVISED GENERATOR LOCATION 2 10-13-2022 REVISED GENERATOR LOCATION 1 07-28-2022 NOISE REPORT 0 05-26-2022 FINAL CDs A 03-04-2022 PRELIMINARY CDs REV. NO. DATE DESCRIPTION OF CHANGES DRAWN BY: SA CHECKED BY: SIP SCALE: NOTED JOB NO: 21 W0057.001 I DRAWING TITLE: COMPOUND PLAN DRAWING SHEET: SE01705E N FIRDALE VILLAGE/ DENTAL CROWN BU #826146 10014 238TH STREET SW EDMONDS, WA 98020 SHEET NO. 5 OF 15 '� M H 0� qF 1 ASy ONAk- TRISTRAM HOKENSON, P.E. WASHINGTON PROFESSIONAL ENGINEER LICENSE #: 54901 GENERAL NOTES C PROPOSE! O 5' C/C PROPOSED T-MOBILE Q AND 240 GALLON BELL 4'-0" x9'-0" CONCRETE PAD AND LEASE AREA (SEE SHEET A-1 FOR EQUIPMENT PLAN) STING —6" STEALTH MONOPOLE )POSED T-MOBILE 120/240VAC, 10, 200A OMATIC TRANSFER SWITCH (ATS) MOUNTED EXISTING BACKBOARD (INTERCEPT DMING EXISTING COMMERCIAL POWER E SHEET A-1 FOR EQUIPMENT PLAN S-2 SCALE:1/4"=1'-0" GRAPHIC SCALE 4 0 - ( IN FEET ) 1/4 inch = 1 ft. (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 16 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, JAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITIES COMPANY OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, N WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 'Pm Mobile • poli T-MOBILE WEST LLC 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WASHINGTON 98011 SSynergy a division of advantage engineers 7543 WOODLEY AVENUE SUITE 201 VAN NUYS, CALIFORNIA 91406 7. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. (THERE IS NO SAC: SAM BUTLER HANDICAP ACCESS REQUIRED). T-MOBILE: ALLAN BATUSAN 8. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR I I A&E: TRISTRAM HOKENSON SANITARY SERVICE. 9. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE RECEPTACLES. 10. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE, NO SIGNS WILL BE POSTED EXCEPT THOSE REQUIRED. 11. NO SIGNIFICANT NOISE, SMOKE, DUST OR ODOR WILL RESULT FROM THIS FACILITY. 12. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88). BLD2022-0769 REVISION May 10 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEDULE OF REVISIONS 6 5 4 3 04-18-2023 REVISED GENERATOR LOCATION 2 10-13-2022 REVISED GENERATOR LOCATION 1 07-28-2022 NOISE REPORT 0 05-26-2022 FINAL CDs A 03-04-2022 PRELIMINARY CDs REV. NO. DATE DESCRIPTION OF CHANGES DRAWN BY: SA CHECKED BY: SIP SCALE: NOTED JOB NO: 21 WO057.001 DRAWING TITLE: ELEVATION DRAWING SHEET: S=2 SE01705E N FIRDALE VILLAGE/ DENTAL CROWN BU #826146 10014 238TH STREET SW EDMONDS, WA 98020 SHEET NO. 6 OF 15 TRISTRAM HOKENSON, P.E. WASHINGTON PROFESSIONAL ENGINEER LICENSE #: 54901