ECE-PRCCECA-DRZB_SUBMITTAL_1Date: Weights: Units: Part Number: gMicroMet l 8/23/2017 1761bs/79.83kg ECE-PRCCECA-DRZB Submitted To: Job: Notes: Economizer - Ultra Low Leak Economizer, Horizontal Orientation, ReliaTel Controller, Differential Enthalpy Sensor, Belimo Actuator. Painted Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels And Hardware Included. A RTVM Ventilation Module Is Required From Trane Factory When A CO2 Sensor Is Combined With Any Of The Following... Multi -Speed, VAV, Or Zone Sensor. External, gear driven Direct coupled dampers. actuators. .0" Return air damper (external) 18.4" and sleave. 30.0" 20.375" Stainless steel blade side seal on return and Actuator access. outside air blades. R/A Outside air damper O/A and hood. O Relief hood. Mounts on return air duct. Damper Side View The Information contained in this drawing is the sole property of Micrometl Corporation. Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC -- Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC -- Longview_201 Kodak Blvd., Longview, TX 75602_903.248.4800 Date: Weights: Units: Part Number: gMicroMet l 1761bs/79.83kg 8/23/2017 ECE-PRCCECA-DRZB Submitted To: Job: Notes: Economizer - Ultra Low Leak Economizer, Horizontal Orientation, ReliaTel Controller, Differential Enthalpy Sensor, Belimo Actuator. Painted Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels And Hardware Included. A RTVM Ventilation Module Is Required From Trane Factory When A CO2 Sensor Is Combined With Any Of The Following... Multi -Speed, VAV, Or Zone Sensor. Compliant Economizer: 1. Title 24: Economizers meet California Energy Commission Title 24-2013 / 2016 prescriptive section 140.4 (damper leakage etc.), and when used with ReliaTel TM controls and field supplied TracerTm TD-5 Display Module, meet mandatory section 120.2.i for Fault Detection and Diagnostic requirements. 2. ASHRAE 90.1: Economizers meetASHRAE 90.1-2013/2016 damper leakage requirements as stated in Table 6.4.3.4.3., and meet 2016 Fault Detection and Diagnosis requirements in section 6.4.3.12 when used with ReliaTel TM control systems. 3. IECC: Economizers meet IECC 2012 section C402.4.5.2 and, IECC 2015 sections C403.2.4.3 and C403.3.3.5 for outside air, return air, and relief damper (when provided) leakage requirements, and when used with ReliaTel TM controls and field supplied TracerTm TD-5 Display Module control systems meet IECC 2015 section C403.2.4.7 for Fault Detection and Diagnostic requirements. Note: IECC 2015 section C403.2.4.7.1 requires differential return air sensor, which must be ordered separately. 4. AMCA: Outside air and return air (volume) dampers are AMCA Class 1A rated at 1" w.g. Refer to MicroMetl NS1 catalog sheet on web site for details. Relief air dampers (when provided) are also AMCA rated. Refer to GR1 series catalog sheet on web site for details. Features: • Gear driven design for trouble -free operation, eliminating slippage and binding associated with standard linkage. • Includes assembled rainhood with aluminum water entrainment filters in the outside air section. AIR IERNRGF • Rainhood is sloped for water run-off. AIR PERfORR1RROE • Power exhaust options available. • Logic wiring is field supplied and installed between the commercial 2 stage thermostat and HVAC low voltage terminal board. MicroMetl Corporation certifies that the models GR1 and NS1 shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. The Information contained in this drawing is the sole property of Micrometl Corporation. Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC -- Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC -- Longview_201 Kodak Blvd., Longview, TX 75602_903.248.4800