Loading...
REVIEWED 2019-10-16 Signed Stamped Revision to Permitted Home (6)Design Build 5ervice5, Inc. Engineering & Corlotruction Management 28119 -120th 5t. S.E., Monroe, WA 98272 Phone /Fax: (360) 793-9659 E-mail: rhoWe@dbomonroe.com October 16, 2019 REVIEWED BY CITY OF EDMONDS Eric Thuesen Thuesen Custom Homes 18333 - 85th Place W Edmonds, WA 98020 (425) 772-9401 Subject: Revision to Permitted Residence and Attached Garage at 514 8th Ave N, Edmonds As requested I have reviewed the proposal to cut about 2' off the back of the house we originally engineered for this location with a stamp date of April 20, 2017. We provided engineering for the back foundation wall to be installed last year to act as a retaining wall through the winter with a stamp date of August 22, 2018. The as constructed position of this wall is what necessitated the reduction in building depth. With the revision and review of resulting site elevations the attached garage has been detached, and a one car garage has been added at the basement level of the house. My engineering review of the proposal required the following reviews or changes to the originally approved plans. 1. The lateral engineering had to be redone to address the revision in shear wall lengths, and the detaching and addition of a floor to the garage. Revised engineering sheets for this review and these revisions are included in the first section. 2. Beam and Foundation changes were also required. These changes included: a. Revisions to the floor framing at the kitchen area that resulted from the new garage below extending out 2' past the original basement wall. The deck was reduced in size and the kitchen was reconfigured slightly. b. The retaining wall provided in 2018 has been included with the addition of a ledger design to allow construction of the lower retaining/basement wall similar to the one constructed last year. c. A 10' basement wall was required to allow the entry elevation at the main floor to be accommodated. d. The pile layout and associated pile caps had to be reconfigured and added to to provide support for the basement floor joist and the added pile supported garage floor. The pile caps were all within the original grade beam and pile cap design and the revised and abandoned pile locations have been added and sized. And the pile supported slab was designed. Eric Thuesen Revision to Permitted Residence and Attached Garage at 514 8th Ave N, Edmonds October 16, 2019 Page 2 of 2 3. The detached garage required a gravity analysis for the beams and the foundation design. This is included as the last section of the attached engineering. In addition the new foundation will have to be tied into the retaining wall constructed last year. A detail for the tie in is attached along with engineering summary and detailed calculation sheets are attached to support this. This should provide the required engineering support to the revised plans. If you have any further questions or I can be of any further assistance please call me at the above number. Rick Heide, P.E. President Attachments Standard Foundation Tie -In R. D. Heide, P.E. Design Build Services, Inc. C3(00) IC33-9659 footing tie-in-dfd.clwe SET-XP EPDXY OR AT ADHESIVE MIN 4" EMBEDMENT - INSTALL PER MANUFACTURER'S INSTRUCTIONS - TYP NEW FOUNDATION 10" MIN (� f—REBAR PER PLAN =_ ===� __-�---------a---- -------------- a .Q- Ul =1 11=1 11=1 I I a� a :III —I I_I=1 I I —I tr ------------------- ----------------------- i o a EXISTING FOUNDATION e . 411 TIE-IN NEW FND WITH Ty MIN 3 - 1*4 STUB BAR Foundation Tie-in to Ex. 1=nd. Detail Scale 3/4" = P-0" Design Code = 2015 IRC/IBC 514 Sth Ave N - Lot 2 R. D. Heide, P.E. 514 Sth Ave N, Edmonds, WA 'B5020 Design 5uild Services, Inc. Job M 30221 Thuesen Custom Homes 13(00)-f93-CMO59 3/30/11 20113-10-14 Thuesen Custom Homes -Lot 2 514 Sth Ave N.dwg 5asement Floor Plan lm) Rev 10/14/Ig Scale 1" = 20' Y3 Aspect Ratios 10' 3.5:1 2.8ro' Ile 0"9­ 7_1rod Ik ' w. .... _.E 4.4 4.4 30 2020 30 I YI Upper Floor Plan (u) 183 23b Y3 Q8.0i °J� Y2 35 3.0 Id 3.8 3.8 i YI 17.0 15.0 XI X2 ( X3 Design Code = 2015 IRC/IBC Wind Loads (limmph - Risk Cat 11, Exposure 5, Kzt 1) Selsmlc Load - V = 0.10 t W Seismic Load - Roof Snow load 25 psf 1 514 Sth Ave N - Lot 2 514 Sth Ave N, Edmonds, WA 13a020 Job 0 30221 Thuesen Custom Homes Basement Floor Plan (m) Upper Floor Plan (u) KEY � - STHD14 FULL HEIGHT CONC. WALLS R. D. Heide, P.E. Design Build Services, Inc. (360) 793-9659 3/30/11 Rev 10/14/i9 CRAWL SPACE s Y3 f,6s O I y� tp siS�s elm S� 6s l� 6 O 6 � � F -1 �O �w, l — DTT2Z Inside 4 Outside to deck joist/blocking -- with e" threaded rod between Yl MSTA36 STRAPS REQ'D TOP i 4 BOTTOM OF OPENING S1-6 Sl-6 1'l.0 Xl X2 ►-W7 Y3 Y2 YI 15/19 1 514 Sth Ave N - Lot 2 R. D. Heide, P.E. 514 Sth Ave N, Edmonds, WA 98020 Design Build Services, Inc. Job # 30221 Thuesen Custom Homes (360) -193-CJ(o59 3/30/11 Rev 10/16/19 Seismic Controls Shear Wall Distribution Front Elevation (No Scale) 36 xl 936 1368 16-12 Concrete Walls Shear Wall Distribution Right Elevation Seismic Controls X2 X3 931 93-1 216-I 2161 J46 w 1263 1263 634 934 1683W Concrete Walls YI ' Y2 Wind Controls Detached Garage 665 1 oaO x4 Wind Controls Detached Garage 665 1o8O Y3 I Z 5/9 QA -C'eA$ 10/16/2019 Michael Leachman P.E. 1.71& Design Build 5ervice5, Inc. Engineering and Construction Management 28119 -120th 5t. 5.E„ Monroe, WA 98272 Phone/Fax (360) 793-9659 Thuesen Cuotom Homes-510 8th Ave N, Lot2 A,) Lateral Demand, 5hear Wall Detailing 13.) Gross Loading 13.1) 5eiomic Load 11687 lb 13.2) Wind 8,2.1) Front 5735i lb 10/5 pof MIN 8.2.2) 50e 6800 Ib 10/5 p5f MIN C.) 5hear Wall Loads, WIND C.1) Front X-X Diaph. Between A [of] Freooure Load [ID] Distribution Factors Xin X(i+1)n X1u - X2u 71 61 10 5 710.0 305.0 0.50 0.35 0.50 0.65 Total X2u - X3u 113 200 10 5 1130.0 1000.0 0.50 0.60 0.50 0.40 Total X3u - X4u 35 49 5 10 175.0 490.0 0.00 0.00 1.00 1.00 Total X3m - X4m Totalo 108 V, [Ib] 10 1080.0 0.00 Wall Lengths, [ft] 1.00 v, [plf] Distribution Xin X(i+1)n 355 107 355 198 462 553 565 600 565 400 1165 965 0 0 175 490 0 665 0 5cheduled 5hear 1080 Wall X1u 461.8 14.2 32.5 51-6 X2u 1718.3 23.03 74.6 51-6 X3u 965.0 21.1' 45.7 51-6 X4u 665.0 11.5 57.8 51-6 X1m 461.8 Conc. Wallo X2m 1718.3 Conc. Wallol X3m 965.0 Conc. Wallo X4m 1745.0 16 109.1 51-6 Z1 1746.0 3.0 Fanelo 581.7, LRF Z2 1745.0 24.0 72.7 51-6 10/14/2019 Michael Leachman P.E. 7/9 Design Build 5ervice5, Inc. Engineering and Construction Management 28119 -120th 5t. 5.E., Monroe, WA 98272 Phone/Fax (360) 793-9659 C,2) 5ide Y-Y Distribution Factors Distribution Diaph. Between A [of] Pressure Load [lb] Yin Y(i+1)n Yin Y(i+1)n Y1u - Y2u 36 10, 360.0 0.90 0.10 324 36 15 5 75.0 0.90 0.10 68 8 78 10 780.0 0.45 0.55 351 429 116 5 580.0 0.35 0.65 203 377 Total 946 850 Y2u - Y3u 47 10 i 470.0 0.20 0.80 94 376 43 5 215.0 0.15 0.851 32 183 77 10 770.0 0.70 0.30' 539 231 134 5' 670.0 0.75 0.25 503 168 Total 1168 957 Y1m - Y2m 86 10' 860.0 0.90 0.10 774 86 202 10: 2020.0 0.45 0.55 909 1111 Total 1683 1197 Totals y, [Ib] Wall Lengths, [ft] v, [plf] Scheduled 5hear Wall Y1u 945.5 13.6 69.5 51-6 Y2u 2017.3 24.2 83.4 51-6 Y3u 957.3 41.9' 22.8 51-6 Y1m 2628.5 18.8 139.8 51-6 Y2m 3214.3 Conc. Walls Yam 957.5 Conc. Walls 10/14/2019 Michael Leachman P.E. 8/9 Design Build 5ervice5, Inc. Engineering and Construction Management 28119 -120th St. 5.E., Monroe, WA 98272 Phone/Fax (360) 793-9659 D) Seismic Roof Area 3535 sf Floor Area 1725 sf D.1) Front X-X Dianh. Between A X1u - X2u X2u - X3u X3u - X4u Totalo V, [It Redundancy(p)-D.3 Seismic Shear 6208 1 6208 Seismic Shear 5479 1 5479 Distribution Factors Distribution Load [Ib] Xin X(i+1)n Xin X(i+1)n 1872.1 0.50 0.50 936 936 3039.9 0.45 0.55 1368 1672 0.0 0.45 0.55 0 0 Wall Lengths, [ft] V, [plf] 5cheduled Shear Wall X1 u 936.0 14.2 65.9 X2u 2304.0 23.05 100.0 X3u 1671.9 21.1 79.2 X1m 936.0 Conc. Wallo X2m 2304.0 Conc. Wallo X3m 1671.9 Conc. Wallo D,2) Side Y-Y Dianh. Between A Y1u - Y2u Y2u - Y3u Y1m - Y2m Y2m - Y3m Totalo V, [11 Y1u Y2u Y3u Y1 m Y2m Y3m 956.9 5104.0 2167.1 2200.0 5500.9 5100.9 Distribution Factors Load [lb] Yin Y(i+1)n Yin 1873.8 0.50 0.50 937 4334.2 0.50 0.50 2167 2526.3 0.50 0.50 1263 1867.6 0.50 0.50 934 Wall Lengths, [ft] V, [plf] 13.6 68.9 24.2 125.3 41.9 51.7 18.8 117.0 Conc. Wallo Conc, Walls Distribution Y(i+1)n 937 2167 1263 934 5cheduled Shear Wall 9/9 Design Build Services, Inc. Engineering and Construction Management 28119 -120th St. S.E., Monroe, WA 95272 Window o s Wau !'hone/Fax #(360) 793-9659 X4m 3t <H;ght b Reference AWA SDf WS-2015 Section 4.3.5.3 p 29. Window 2.00 0 ° poor o m t � wall Ho 2 ft a w a °w c c 3N 3N Height (H) Hw 9 ft 22 % b b Lfh 3.00 6,00 3.00 12.00 ft Adj Lfh 2.00 2.67 2.00 6.67 ft Width of s eb hing l4ax Height Lw 24.0 ft 28% Co 100% l Overall Width Design Required Shear adjustment, W 109.1 lb/ft 109 Ib/ft 51-6 Shear adjustment, E N/A Ib/ft #VALUE! Ib/ft #VALUEI Shear Capacity Adjustment Factor Co for Perforated Shearwalls Ratio of opening Maximum window or door height height to wall height H/3 H/2 2H/3 5H/6 H 22% Percent full -height sheathing Effective shear capacity ratio 0% 1.00 0.67 0.50 0.40 0.33 10% 1.00 0.69 0.53 0.43 0.36 20% 1.00 0.71 0.56 0.45 0.38 30% 1.00 0.74 0.59 0.49 0.42 40% 1.00 0.77 0.63 0.53 0.45 50% 1.00 0.80 0.67 0.57 0.50 60% 1.00 0.83 0.71 0.63 0.56 70% 1.00 0.87 0.77 0.69 0.63 80% 1.00 0.91 0.83 0.77 0.71 90% 1.00 0.95 0.91 0.87 0.83 100% 1.00 1.00 1.00 1.00 1.00 280/6 Co 1.00 Dead Load Roof 3 15 1080 lb Walls 16 10 3840lb Floor 0_ _ _ _ 12 0 lb DL= 4920lb (DL*.6)/2= 1476 lb Uplift Calculation Uplift Wind 491 lb 1476 lb -985 lb Uplift Seismic #VALUE! lb 1476 lb #VALUE! lb Hold Down Req'd;,STHD14 F-1 � WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN Thuesen-510 8th Ave N rev 2019.wwa WoodWorksO Sizer 11.1.1 Oct. 15, 2019 09:50:06 Concept Mode: Beam View Floor 2: ill 65' 63' 61' 50, 57'-6„ 56' 54'-6" - 5'�' 51' 48' 46-6" 43'-6" 41,_6" _.... 40' 37' 36' 35' 33' 32' 29' 2-7' 26' 24' 34. �'b24 -b1�9 b19b 19; 21 d 1 b11 b b38" b20 _ Q4�r.. �g� n 18' 19 L b89 b99 _ 15' 20 13' 11 b2 b103 - " 1 12' 3 b21 , P 11' 14 7�+ ' 7' 15 : _. 3' 40 .. �' is 01 AT T A BC]V K\BMADAV. U NARYFJAX AGX NAYAW AlCAHZ C AE' BD ANAUH AO (AN B R SI G AC E AMB AAAF JAE 0' 2' 4' 5'-6"7' 8' 9' 11' 13' 18' 20'-6" 24' 26' 28'-6" 32' 34' 36' 38'-6' 42' 44' 47'-6" 50' 52' 54'-6" 59, 65'-6" 70' 74' 86, 90'-6" 9'-6"-6'2'-6" 17' 1920' 22' 25' 27'-6" 31' 33' 37'-6" 40' 43' 46' 48' 54' 73' 87'-6" 91'-6" COMPANY Design Build Services, Inc. 20th St SE WoodWorkso Monroe, WA 98272 (360) 793-9659 (360) 7 3-9659 SOFFWARE FOR WOOD DESIGN Oct. 15, 2019 09:11 Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads Load Type Distribution Pat- tern Location (ft] Start End Magnitude Start End Unit l c75 Dead Point No 0.00 361 lbs 2 c75 Snow Point Yes 0.00 544 lbs Load3 Dead Full Area No 12.00 psf Load4 Live Full Area Yes 40.00 psf Self -weight Dead Full UDL No 1.9 plf Maximum Reactions (lbs): 13' PROJECT 510 8th Ave N - Lot 2 510 8th Ave N Edmonds, WA 98020 Thuesen Custom Homes b89.wwb Unfactored: Dead 563 30 Live 410 293 Snow 643 -99 Factored: Uplift -69 Total 1353 323 b89 1-Joist, APA PRI, PRI-50, 1-3/4"x11-7/8" Supports: All - Non -wood Floorjoist spaced at 16" c/o; Total length: 13` Clear span: 2% 1V Analysis vs. Allowable Stress and Deflection using Nos 2015 : Criterion Analysis Value Design Value Unit Analysis/Design Shear V = 940 Vr = 1633 hips V/Vr = 0.58 Bending(+) M = 732 Mr = 4915 kip-ft M/Mr = 0.15 Bending(-) 1.1 = 1845 Mr = 5652 kip-£t M/Mr = 0.33 Deflection: -0.01 = <L/999 Interior Dead Live 0.05 = <L/999 0.28 = L/480 in 0.19 Total 0.04 = <L/999 0.55 = L/240 in 0.07 Cantil. Dead 0.02 = <L/999 Live 0.05 = L/512 0.10 = L/290 in 0.47 Total 0.07 = L/345 0.20 = L/120 in 0.35 Additional Data: FACTORS: F/E CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC4 Vr 1420 1.15 - - - - - - 1.00 - - 4 Mr+ 4915 1.00 - - - - - 1.00 1.00 - - 6 Mr- 4915 1.15 - - - - - 1.00 1.00 - - 4 EI 316.0 million - - - - - - 1.00 - - 6 CRITICAL LOAD COMBINATIONS: Shear : LC 44 = D+S, V max = 940 lbs Bending(+): LC 46 = D+L (pattern: L), M = 732 lbs-ft Bending(-): LC 04 = D+S, 1.1 = 1845 lbs-ft Deflection: LC 46 = (live) LC 04 = D+S (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load Patterns: s=S/2, X=L+S or L+Lr, =no pattern load in this span Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 348e06 lb-in2 K= 27.49e06 lbs "Live" deflection = Deflection from all non -dead loads (live, wind, snow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. Design Notes: 1. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Wood Works Sizer provides preliminary estimates for kjoist design. Each wood I -joist producer develops its own proprietary design values. Please contact the manufacturer for a custom I -joist version of Sizer or other I -joist design software. 4. The critical deflection value has been determined using maximum back -span deflection. Cantilever deflections do not govern design. COMPANY Design Build Services, Inc. PROJECT 510 8th Ave N - Lot 2 Monroe, WA 98272 510 eth Ave N Edmonds, WA 98020 WoodWorks' (360) 7 3-9h 59SE (360) 793-9659 Thuesen Custom Homes Oct. 15, 2019 09:17 b90.wwb W Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads: Load Type Distribution Pat- tern Location Ifni Start End Magnitude Start End Unit 1.79 Dead Point No 7.51 32 lbs 2 c79 Snow Point Yes 7.81 50 lbs Load3 Dead Full UDL t!o 16.0 plf Load4 Dead Partial UDL tto 0.04 6.04 16.0 16.0 plf Loads Live Partial UDL Yes 0.04 6.04 53.3 53.3 plf Self -weight Dead Full UDL tto 1.9 if Maximum Reactions (lbs): 8'-0.5" A 6-0.25" 8'-025" Unfactorsd• Dead 87 185 Live 159 160 1.. -15 65 Factored: Total 246 354 Bearing: Length 0.5V 0.00 Erin re 'd 0.50- 0.00 'Minimum bearing length setting used: 1/2" for end supports Maximum reaction on at least one support is from a different load combination than the critical one forbearing design, shown here, due to Kd factor. See Analysis results for reaction from critical load combination. b90 I -Joist, APA PRI, PRI-50, 1-3/4"All-7/8" Supports: 1 - Lumber -soft Beam, D.Fir-L No.2; 2 - Non -wood; Floorjoist spaced at 16" c1c; Total length: 8'-0.5'; Clear span: 6'. 2' Analysis vs. Allowable Stress and Deflection using Nos 2016 : Criterion Analysis s Value DesignValue Unit Anal sis/Desi Shear V =278 Vr 1420 kips V w = 0n20 Bending(+) it = 350 it = 4"1 kip-ft t4/tor = 0.07 Bending(-) M = 182 Dir = 1652 kip-ft 11/Mr = 0.03 Deflection: Interior Dead 0.00 = <L/999 Live 0.00 = <L/999 0.15 = L/480 0.03 Total 1.11 = <L/999 0.30 = L/240 in 0.02 Cantil. Dead negligible Live -0.00 = <L/999 0.10 = L/240 in 0.05 Total -0.01 = <L/999 0.20 = L/120 0.03 Additional Data: FACTORS: F/E CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Vr 1420 1.00 - - - - - - 1.00 - - 2 Dlr+ 4915 1.00 - - - - - 1.00 1.00 - - 2 tdr- 4915 1.15 - - - - - 1.00 1.00 - - 4 EI 316.0 million - - - - - - 1.00 - - 2 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D+L, V max = 278 lbs Bending(+): LC 42 = D+L, M = 350 lb a- Bending(-): LC #4 = D+S, 1 = 182 lbs-ft Deflection: LC #2 = D+L (live) LC #2 = D+L (total) D=dead L=1ive S=snow W=wind 1-impact Lr=roof live Lc=concentrated E=earthquake A LC's are listed in the Analysis output Load Patterns: s=S/2, %=L+S or L+Lr, - o pattern load in this span Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 348e06 lb-in2 K= 27.49e06 lbs "Live" deflection = Deflection from all roc -dead loads hive, wind, Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.n Design Notes: 1. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NOS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Wood Works Sizer provides preliminary estimates for I-jolst design. Each wood I -joist producer develops its own proprietary design values. Please contact the manufacturer for a custom I -joist version of Sizer or other I -Joist design software. deflection. Cantilever deflections do not COMPANY Design Build Services, Inc. PROJECT 510 elh Ave N - Lot 2 Tj R BE Monroe, WA 98272 13-9h 510 8ih Ave N Edmonds, WA 98020 WoodWork s 59 (360) 793-9659 (360) Thuesen Custom Homes Oct. 15, 2019 09:04 b99.wwb IGN Design Check Calculation Sheet Wood Works Sizer 1i1AA Loads: Load Type Distribution Pat- Location [ftl magnitude Maximum Reactions (lbs) and Bearing Lengths (in) 1 T-2.49" 0' 2'- . 1" 1311.86" **Minimum bearing length governed by the required width of the supporting member. Maximum reaction on at least one support is from a different load combination than the critical one for bearing design, shown here, due to Kd factor. See Analysis results for reaction from critical load combination. b99 PSL, ME, 2.OE, 5-1/4"x11-7/8" Supports: All - Timber -soft Column, D.Fir-L No.2 Total length: 13'-2.49"; Clear span: 2% 11 ; volume = 5.7 cu.R. Lateral support: top= full, ballom= at supports: Analysis vs. Allowable Stress and Deflection using NOS 2015: in Additional Data: FACTORS: F/E(psi)CD CM Ct CL cV Cfu Cr Cfrt Ci Cn LC4 Fv' 290 1.15 - 1.00 - - - - 1.00 - 1.00 2 Fb'+ 2900 1.15 - 1.00 1.000 1.00 - 1.00 1.00 - - 4 Fb'- 2900 1.15 - 1.00 0.997 1.00 - 1.00 1.00 - - 2 Fcp' 750 - - 1.00 - - - - 1.00 - - - E' 2.0 million - 1.00 - - - - 1.00 - - 4 Eminy' 1,04 million - 1.00 - - - - 1.00 - - 4 CRITICAL LOAD COMBINATIONS: Shear LC k2 = D+S, V m = 4952, V design = 4798 lb. Bending(+): LC p4 = D+S (pattern: s51, hi = 24186 lbs-ft Bending(-): LC 42 = D+S, M = 515 lbs-ft Deflection: LC #4 = (live) LC 44 = (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load Patterns: s=5/2, X=L+S or L+Lr, - o pattern load in this span Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 1465eO6 lb-in2 "Live" deflection = Deflection from all non -dead loads (live, wind, s ow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflaetion.n Lateral stability(-): Lu = 2'-0.63" Le = 3'-10.00'. RP = 4.5; In based on full span Design Notes: 1. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NOS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. SCL-BEAMS (Structural Composite Lumber): the attached SCL selection is for preliminary design only. For final member design contact your local SCL manufacturer. 4. Size factors vary from one manufacturer to another for SCL materials. They can be changed in the database editor. 5. The critical deflection value has been determined using maximum back -span deflection. Cantilever deflections do not govern design. tern Start End Start End Unit 1 w52 Dead Partial UDL t!o 0.00 2.00 15.3 15.3 plf 2 w52 Snow Partial UDL Yes 0.00 2.00 25.0 25.0 plf 3 c76 Dead Point tto 2.00 264 lb. 4 c76 Snow Point Yes 2.00 370 lbs 5 c77 Dead Point fro 7.82 3120 1bs 6 c77 Snow Point Yes 7.82 9731 lb 7 c124 Dead Point No 0.00 78 lbs 8 c124 Snow Point Yes 0.00 112 lbs Lead' Dead Partial UDL No 2.00 13.00 150.0 150.0 plf Self-crei eight Dead Fu11 UDL No 19.5 if Unfactored: Dead 2880 2518 Snow 2829 2496 Factored: Total 5709 9964 Dearing: Length 1.23 1.26 Fiin r 'd 1.23*" 1.26 Criterion Analysis Value Design Value Unit Mal sis/Desi n Shear fv = 115 Fv' = 333 psi fv Fv' = 0.35 Bending(+) fb = 2352 Fb' = 3338 = 0.70 Hendingl-) fb = 50 Eb' = 3329 Nifb/Fb' psi fb/Fb' = 0.02 Deflection: Interior Dead 0.14 = L/937 Live 0.16 = L/846 0.37 = L/360 0.93 Total 0.30 = L/499 0.56 = L/240 n 0.54 Cant il.Dead -0.08 = L/319 Live -0.09 = L/286 0.19 = I./180 0.62 Total -0.16 = L/150 0.21 = L/120 in 0.80 Cantilever Retaining Wall R. F-). Heide, P.E. Thuesen Lot 2 2:1 5ackslope F-)eeien E3uild Services, Inc. (3(00) 1133-e(0513 0/21/18 CONCRETE Fr-=2500psi 10/15/19 Added Ledger REINFORCING STEEL Fy=&0ks1 FRAMING 5ACKFILL SAND OR GRAVEL A50VE ti ANCHOR 501-T PER SHR SCH. 1\0Z > 414 @ 10" o.r-. NOR. ,—A VERT. x X 2° CLEAR 10 MIL J"x-1 TITEN 010" or— VAPOR BARRIER Staggered IT L2 ca z LU Ir Cil C, 5ars w/ hook 0 ---' 5,5' wall 4 04 LONG. 06. DRAIN REQ. Wall section No 6r-a I(s 5 HOOK BARS Bar Spacing (o.c.) tI H t2 LI L2 L3 E3 C, all 5.51 101, 2011 (oil 30" � 12 � 12 all 1.51 HII 3111 1211 3 0 " *S '@ 12 #5 012 #5 � 12 I ;�,� �� S � � o'u � YZ`'r' M � Cc �o � �n [O I vS \\q ra WO $ Tck Lei Z E. v Zit �%3 -> oL,41V�, 100 t,5 --�5-" - G-sf` Ire , -v -7 � L-, e 4/ZO %7 420 Z+ 0 I 1.75 x I _ 11 1/9 QuickWall 8.1 - RETAINING WALL ANALYSIS AND DESIGN -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- Job ID 30142 Job Description : Basement 5`-6 ft wall w-slope Designed By : RDH PE -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- yt� 02- s.00 i . 1. ft. • 0.50 ft. 5.50 ft. 35.00 pcf. i 0.00 in. 1,950 psf. ' 2.83 R. 8/21/2018 5:18 PM QuickWall 8.1 - RETAINING WALL ANALYSIS AND DESIGN 2/9 Job ID 30142 Job Description : Basement 5'-6 ft wall w-slope Designed By : RDH PE -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- FOOTING DESIGN METHOD: Ultimate Strength ACI 318-11 STEM DESIGN METHOD Ultimate Strength ACI 318-11 (Concrete) WALL TYPE Cantilever Retaining Wall RETAINING WALL DIMENSIONS: ------------------------------------ Wall Stem Height = 5.50 ft. Stem Thickness @ Top = 8.00 in. Stem Thickness @ Bottom = 8.00 in. Footing Thickness = 10.00 in. Heel Width . . . . . . Min. = 0.33 ft. Max. = 3.00 ft. Toe Width . . . . . . Min. = 0.33 ft. Max. = 0.50 ft. Footing Key Depth = 0.00 ft. Footing Key Width = 0.00 ft. Backfill Slope (Vert/Horiz) = 6.00 :12 RETAINING WALL LOADS: Design Heel Width = 1.66 ft. Design Toe Width = 0.50 ft. Design Key Depth = 0.00 ft. Design Key Width = 0.00 ft. Horizontal Equivalent Fluid Pressure = 35.00 pcf. Backfill Height = 5.00 ft. Equivalent Fluid Pressure Angle = 0.00 deg. Vertical Surcharge on Backfill = 0 psf. Horizontal Surcharge = 0 psf. Vertical Surcharge on Toe = 0 psf. Wind Load on Fence = 0 psf. Fence Height = 0.00 ft. Line Ld. Type No. (H or V) 1 2 3 4 5 6 7 8 9 10 Magnitude Dist. (x) Load Case (plf) (ft.) (Load Case = Soil) (Load Case = Soil) (Load Case = Wind) (Load Case = Soil) (Load Case = Wind) Notes: 1. "H" = Horizontal loads. "V" = Vertical loads. 2. Vertical loads are positive down. 8/21/2018 5:18 PM 1 of 8 3/9 ULTIMATE STRENGTH LOAD COMBINATIONS (Concrete Design): ------------------------------------ 1. 4D + 1.4H 1.2D + 1.6L + 1.6H + 0.5R 1.2D + 1.6R + 1.6H + 1.OL 1.2D + 1.6R + 1.6H + 0.5W 1.2D + 1.OW + 1.OL + 0.5R 1.2D + 1.0E + 1.OL + 1.6H + 0.2R 0.9D + 1.OW + 1.6H 0.9D + 1.0E + 1.6H WORKING STRESS LOAD COMBINATIONS (Stability Checks and Masonry Design): ------------------------------------ D + L + R + H D + L + 0.6W + H D + L + 0.6W + 0.5R + H D + L + R + 0.3W + H D + L + R + E/1.4 + H D + E/1.4 + H 8/21/2018 5:18 PM 2 of 8 4/9 RETAINING WALL RESISTING FORCES: ------------------------------------ Allowable Soil Pressure = 2,000 psf. Passive Equivalent Fluid Press. = 300.00 pcf. Passive Soil Height = 0.00 ft. Coefficient of Friction = 0.50 Cohesion = 500 psf. Use Vertical Surcharge as Resisting Wt.? = Yes Overturning Safety Factor = 1.50 Sliding Safety Factor = 1.50 Limit Reaction to Mid 1/3? = No MATERIAL DATA: ------------------------------------ Concrete Strength, f'c = 2.50 ksi. Steel Yield Strength, Fy = 60.00 ksi. Concrete Unit Weight = 150.00 pcf. Soil Unit Weight = 110.00 pcf. Fence Weight = 10.00 psf. REINFORCING STEEL DATA: Concrete cover to center of steel: Wall Inside Face = 2.25 in. Footing Heel (Top Face) = 2.25 in. Footing Toe (Bottom Face) = 3.25 in. Minimum Ratios for Shrinkage and Temperature Reinf: Vertical Stem Reinf. = 0.0018 Horizontal Stem Reinf. = 0.0020 Footing Reinforcement = 0.0018 8/21/2018 5:18 PM 3 of 8 ************************************************** 5/ 9 S U M M A R Y O F R E S U L T S ************************************************** DIMENSIONS: Stem Height = 5.50 ft. Heel Length = 1.66 ft. Stem Thick. @ Top = 8.00 in. Toe Length = 0.50 ft. Stem Thick. @ Base = 8.00 in. Total Ftg. Width, B = 2.83 ft. Footing Thickness = 10.00 in. Key Depth = 0.00 ft. Key Width = 0.00 ft. ANALYSIS RESULTS: Max Brg Press. @ Toe = 1,950 psf. @ Heel = 0 psf. Allowable Brg. Press. = 2,000 psf. Resultant Loc From C.L.= 0.77 ft. Kern Point Loc., B/6 = 0.47 ft. Limit Resultant To Mid 1/3? = No Sliding Force = 777 Lb Resisting Force = 2,023 Lb F.O.S. = 2.60 Overturn. Moment = 1,727 ft-lb Resisting Moment = 2,954 ft-lb F.O.S. = 1.71 -------------------------------------------------------------------------------- DESIGN RESULTS: Design Method, Stem: USD, ACI 318-11 (Concrete) Ftg.: Ultimate Strength ACI 318-11 d Mu Vu Phi Vn As Flex. As Min. As T+S (in.) (ft-k) (kip) (kip) (in^2) (in^2) (in^2) Stem 5.75 1.85 0.95 5.18 0.073 0.097 0.197 Toe 6.75 0.94 1.70 6.08 0.031 0.041 0.216 Heel 7.75 1.31 1.44 6.98 0.038 0.051 0.216 Key 0.00 0.00 0.00 0.00 0.000 0.000 0.000 Notes: 1. Stem moments are positive if they cause tension on the soil face. Negative if they cause tension on the outside face. Stem shear is positive to the left as measured on a section cut below the top of wall. 2. Heel moments are positive if they cause tension in the top of the footing. Heel shear is positive up as measured on a section cut to the right of the end of the heel. 3. Toe moments are positive if they cause tension in the bottom of the footing. Toe shear is positive up as measured on a section cut to the left of the end of the toe. 8/21/2018 5:18 PM 4 of 8 ************************************************** 6/9 S T A B I L I T Y A N A L Y S I S R E P O R T ************************************************** --------------------------------------------------------- Stability Analysis: Governing Combination = D + L + R + H ----------RESISTING FORCES --------- ---------OVERTURNING FORCES--------- ElementWeight x Arm = Moment Element Force x Arm = Moment Soil 991 1,998 R at Top Ftg. 353 1.41 499 R at Bot. Stem 550 0.83 457 Horiz. EFP 777 2.22 1,727 Vert Sur Vert Sur Vert EFP Horiz Sur Toe Sur. Wind Fence Wt. Horiz line V. line Vert. line Sum WT = -------- 1,894 MR = -------- 2,954 -------- -------- Sum F = 777 MOT = 1,727 Friction Force = 947 Lb Passive Pressure = 104 Lb Cohesion = 971 Lb Resist. Force, Sum RF = 2,023 Lb F.O.S. Sliding = RF / F = 2.60 F.O.S. Overturn. = MR / MOT = 1.71 Coef. Vert. Surcharge or Line Load to Horiz. = EFP / Soil Dens. = 0.318 Resultant Loc From Toe, X = (MR - MOT) / Sum WT = 0.65 ft. Eccentricity From Ftg. C.L., e = (B / 2) - X = 0.77 ft. Soil Pressure @ Toe = (2 * WT) / (3 * X) = 1,950 psf. Soil Pressure @ Heel = = 0 psf. 8/21/2018 5:18 PM 5 of 8 ************************************************** 7/ 9 D E T A I L E D D E S I G N R E P O R T ************************************************** -------------------------------------------------------------------------------- STEM DESIGN: Steel Design Comb = 1.2D + 1.6L + 1.6H + 0.5R Shr Strength @ Base, Phi Vn = 5.18 kip Dist From d Mu Vu As Flex. As Min. As T+S As Reqd Comb Top (ft) (in.) (ft-k) (kip) (in^2) (in^2) (in^2) (in^2) 0.55 5.75 0.01 0.02 0.000 0.000 0.173 0.173 2 1.10 5.75 0.03 0.06 0.001 0.001 0.173 0.173 2 1.65 5.75 0.07 0.11 0.003 0.004 0.173 0.173 2 2.20 5.75 0.15 0.18 0.006 0.008 0.173 0.173 2 2.75 5.75 0.27 0.27 0.011 0.014 0.173 0.173 2 3.30 5.75 0.45 0.37 0.017 0.023 0.173 0.173 2 3.85 5.75 0.68 0.49 0.027 0.035 0.173 0.173 2 4.40 5.75 0.99 0.63 0.039 0.051 0.173 0.173 2 4.95 5.75 1.38 0.78 0.054 0.072 0.173 0.173 2 5.50 5.75 1.85 0.95 0.073 0.097 0.197 0.197 2 -------------------------------------------------------------------------------- Vertical Stem Reinforcement: Shear -Friction Steel Added at Stem Base (ACI 11 11.6), Avf = 0.024 in^2 Available Length for Hook Embedment into Footing = 7.25 in. Available Length for Straight Embedment into Stem = 64.00 in. Development Length Straight Hook Percent Spac. 50o Cut Off (in.) (in.) Develop. (in.) (in.) #4 14.40 8.40 86.31 10.51 66.00 #5 18.00 10.50 69.05 13.03 66.00 #6 21.60 12.60 57.54 15.42 66.00 #7 31.50 14.70 49.32 18.00 66.00 #8 40.00 16.80 43.15 18.00 66.00 #9 50.90 18.95 38.26 18.00 66.00 #10 64.52 21.34 33.98 18.00 66.00 #11 79.52 23.69 30.61 18.00 66.00 -------------------------------------------------------------------------------- Horizontal Stem Reinforcement: Area of steel for Shrinkage and Temp. Reinforcement = 0.192 in^2 -----Spacing, in.----- ------Total Bars------ I.F. Only EA. Face I.F. Only EA. Face #4 12.50 18.00 6.00 5.00 #5 18.00 18.00 5.00 5.00 #6 18.00 18.00 5.00 5.00 #7 18.00 18.00 5.00 5.00 #8 18.00 18.00 5.00 5.00 #9 18.00 18.00 5.00 5.00 #10 18.00 18.00 5.00 5.00 #11 18.00 18.00 5.00 5.00 8/21/2018 5:18 PM 6 of 8 8/9 TOE DESIGN: * Steel Design Comb. = 0.9D + 1.OW + 1.6H * Thickness Design Comb. = 0.9D + 1.OW + 1.6H * Available Length for Hook Embedment into Stem = 6.25 in. * Available Length for Straight Embed. into Toe = 3.96 in. -------------------------------------------------------------------------------- d Mu Vu Phi Vn As Flex. As Min. As T+S As Req'd (in.) (ft-k) (kip) (kip) (in^2) (in^2) (in^2) (in^2) 6.75 0.94 1.70 6.08 0.031 0.041 0.216 0.216 -------------------------------------------------------------------------------- Development Length Straight Hook Percent Spac. ,- (in.) (in.) Develop. (i-n- ) t .. #4 14.40 8.40 27.50, 3.06ft- #5 18.00 10.50 72,2:00 3.79 #6 21.60 12 18.33 4.48 #7 78.75 70 5.03 1.68 ` #8 90.010 16.80 4.40 1.93 #9 18.95 3.90 2.17 #10 ,,Ial.52 114.30 21.34 3.46 2.44 #11 126.90 23.69 3.12 2.70 -------------------------------------------------------------------------------- HEEL DESIGN: * Steel Design Comb. = 1.4D + 1.4H * Thickness Design Comb. = 1.2D + 1.6L + 1.6H + 0.5R * Available Length for Straight Embedment into Toe = 11.96 in. * Available Length for Straight Embedment into Heel = 17.96 in. -------------------------------------------------------------------------------- d Mu Vu Phi Vn As Flex. As Min. As T+S As Req'd (in.) (ft-k) (kip) (kip) (in^2) (in^2) (in^2) (in^2) 7.75 1.31 1.44 6.98 0.038 0.051 0.216 0.216 -------------------------------------------------------------------------------- Development Length Straight Hook Percent Spac. (in.) (in.) Develop. (in.) �t #4 14.40 8.40 9.23 Q #5 18.00 10.50 6.44 (\55_ 11.44Z--- #6 21.60 12.60 13.53 #7 31.50 14.70 37.97 12.66 #8 40.00 16.80 29.90 13.12 #9 50.90 18.95 23.50 13.06 #10 64.52 21.34 18.54 13.08 #11 79.52 23.69 15.04 13.03 8/21/2018 5:18 PM 7 of 8 9/9 LONGITUDINAL FOOTING REINFORCEMENT (TEMP & SHRINK ONLY): Spacing (in.) #4 11.11 #5 17.22 #6 24.44 #7 33.33 #8 43.89 #9 55.56 #10 70.56 #11 86.67 8/21/2018 5:18 PM 8 of 8 1/9 QuickWall 8.1 - RETAINING WALL ANALYSIS AND DESIGN -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- Job ID 30142 Job Description : Basement 7' ft wall w-slope Designed By : RDH PE -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- ti VY r t. 35.00 ptf. 2.58 ft. 1.00 R. .50 ft. 1.00 in. 1,957 psf. 4.25 R. 8/22/2018 9:10 AM 2/9 QuickWall 8.1 - RETAINING WALL ANALYSIS AND DESIGN -------------------------------------------------------------------------------- Job ID 30142 Job Description : Crawlspace 7' ft wall w-slope Designed By : RDH PE -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- FOOTING DESIGN METHOD: Ultimate Strength ACI 318-11 STEM DESIGN METHOD Ultimate Strength ACI 318-11 (Concrete) WALL TYPE Cantilever Retaining Wall RETAINING WALL DIMENSIONS: ------------------------------------ Wall Stem Height - 7.50 ft. Stem Thickness @ Top - 8.00 in. Stem Thickness @ Bottom = 8.00 in. Footing Thickness = 11.00 in. Heel Width . . . . . . Min. = 0.33 ft. Max. = 4.00 ft. Toe Width . . . . . . Min. = 0.75 ft. Max. = 1.00 ft. Footing Key Depth = 0.00 ft. Footing Key Width = 0.00 ft. BackFill Slope (Vert/Horiz) = 6.00 :12 RETAINING WALL LOADS: Design Heel Width = 2.58 ft. Design Toe Width = 1.00 ft. Design Key Depth = 0.00 ft. Design Key Width = 0.00 ft. Horizontal Equivalent Fluid Pressure = 35.00 pcf. Backfill Height = 7.00 ft. Equivalent Fluid Pressure Angle = 0.00 deg. Vertical Surcharge on Backfill = 0 psf. Horizontal Surcharge = 0 psf. Vertical Surcharge on Toe = 0 psf. Wind Load on Fence = 0 psf. Fence Height = 0.00 ft. Line Ld. Type No. (H or V) 1 2 3 4 5 6 7 8 9 10 Magnitude Dist. (x) Load Case (plf) (ft.) (Load Case = Soil) (Load Case = Soil) (Load Case = Wind) (Load Case = Soil) (Load Case = Wind) Notes: 1. "H" = Horizontal loads. "V" = Vertical loads. 2. Vertical loads are positive down. 8/22/2018 9:10 AM 1 of 8 ULTIMATE STRENGTH LOAD COMBINATIONS (Concrete Design): ------------------------------------ 1. 4D + 1.4H 1.2D + 1.6L + 1.6H + 0.5R 1.2D + 1.6R + 1.6H + 1.OL 1.2D + 1.6R + 1.6H + 0.5W 1.2D + 1.OW + 1.OL + 0.5R 1.2D + 1.0E + 1.OL + 1.6H + 0.2R 0.9D + 1.OW + 1.6H 0.9D + 1.0E + 1.6H WORKING STRESS LOAD COMBINATIONS (Stability Checks and Masonry Design): ------------------------------------ D + L + R + H D + L + 0.6W + H D + L + 0.6W + 0.5R + H D + L + R + 0.3W + H D + L + R + E/1.4 + H D + E/1.4 + H 3/9 8/22/2018 9:10 AM •00 4/9 RETAINING WALL RESISTING FORCES: ------------------------------------ Allowable Soil Pressure = 2,000 psf. Passive Equivalent Fluid Press. = 300.00 pcf. Passive Soil Height = 0.00 ft. Coefficient of Friction = 0.50 Cohesion = 500 psf. Use Vertical Surcharge as Resisting Wt.? = Yes Overturning Safety Factor = 1.50 Sliding Safety Factor = 1.50 Limit Reaction to Mid 1/3? = No MATERIAL DATA: ------------------------------------ Concrete Strength, f'c = 2.50 ksi. Steel Yield Strength, Fy = 60.00 ksi. Concrete Unit Weight = 150.00 pcf. Soil Unit Weight = 110.00 pcf. Fence Weight = 10.00 psf. ------------------------------------ Concrete cover to center of steel: Wall Inside Face = 2.25 in. Footing Heel (Top Face) = 2.25 in. Footing Toe (Bottom Face) = 3.25 in. Minimum Ratios for Shrinkage and Temperature Reinf: Vertical Stem Reinf. = 0.0018 Horizontal Stem Reinf. = 0.0020 Footing Reinforcement = 0.0018 8/22/2018 9:10 AM 3 of 8 ************************************************** 5/9 S U M M A R Y O F R E S U L T S -------------------------------------------------------------------------------- DIMENSIONS: Stem Height = 7.50 ft. Heel Length = 2.58 ft. Stem Thick. @ Top = 8.00 in. Toe Length = 1.00 ft. Stem Thick. @ Base = 8.00 in. Total Ftg. Width, B = 4.25 ft. Footing Thickness = 11.00 in. Key Depth = 0.00 ft. Key Width = 0.00 ft. ANALYSIS RESULTS: Max Brg Press. @ Toe = 1,957 psf. @ Heel = 0 psf. Allowable Brg. Press. = 2,000 psf. Resultant Loc From C.L.= 0.93 ft. Kern Point Loc., B/6 = 0.71 ft. Limit Resultant To Mid 1/3? = No Sliding Force = Resisting Force = F.O.S. _ Overturn. Moment = Resisting Moment = F.O.S. _ 1,483 Lb 3, 668 Lb 2.47 4,552 ft-lb 8,734 ft-lb 1.92 -------------------------------------------------------------------------------- DESIGN RESULTS: Design Method, Stem: USD, ACI 318-11 (Concrete) Ftg.: Ultimate Strength ACI 318-11 d Mu Vu Phi Vn As Flex. As Min. As T+S (in.) (ft-k) (kip) (kip) (in^2) (in^2) (in^2) Stem 5.75 5.32 1.92 5.18 0.215 0.230 0.229 Toe 7.75 2.51 2.71 6.98 0.073 0.097 0.238 Heel 8.75 3.94 2.72 7.88 0.101 0.135 0.238 Key 0.00 0.00 0.00 0.00 0.000 0.000 0.000 Notes: 1. Stem moments are positive if they cause tension on the soil face. Negative if they cause tension on the outside face. Stem shear is positive to the left as measured on a section cut below the top of wall. 2. Heel moments are positive if they cause tension in the top of the footing. Heel shear is positive up as measured on a section cut to the right of the end of the heel. 3. Toe moments are positive if they cause tension in the bottom of the footing. Toe shear is positive up as measured on a section cut to the left of the end of the toe. 8/22/2018 9:10 AM 4 of 8 ************************************************** 6/9 S T A B I L I T Y A N A L Y S I S R E P O R T ************************************************** --------------------------------------------------------- Stability Analysis: Governing Combination = D + L + R + H ----------RESISTING FORCES --------- ---------OVERTURNING FORCES--------- ElementWeight x Arm = Moment Element Force x Arm = Moment Soil 2,170 6,494 R at Top Ftg. 584 2.12 1,240 R at Bot. Stem 750 1.33 1,000 Horiz. EFP 1,483 3.07 4,552 Vert Sur Vert Sur Vert EFP Horiz Sur Toe Sur. Wind Fence Wt. Horiz line V. line Vert. line Sum WT = -------- 3,504 MR = -------- 8,734 -------- -------- Sum F = 1,483 MOT = 4,552 Friction Force = 1,752 Lb Passive Pressure = 126 Lb Cohesion = 1,790 Lb Resist. Force, Sum RF = 3,668 Lb F.O.S. Sliding = RF / F = 2.47 F.O.S. Overturn. = MR / MOT = 1.92 Coef. Vert. Surcharge or Line Load to Horiz. = EFP / Soil Dens. = 0.318 Resultant Loc From Toe, X = (MR - MOT) / Sum WT = 1.19 ft. Eccentricity From Ftg. C.L., e = (B / 2) - X = 0.93 ft. Soil Pressure @ Toe = (2 * WT) / (3 * X) = 1,957 psf. Soil Pressure @ Heel = = 0 psf. 8/22/2018 9:10 AM 5 of 8 ************************************************** 7/9 D E T A I L E D D E S I G N R E P O R T ************************************************** -------------------------------------------------------------------------------- STEM DESIGN: Steel Design Comb = 1.2D + 1.6L + 1.6H + 0.5R Shr Strength @ Base, Phi Vn = 5.18 kip Dist From d Mu Vu As Flex. As Min. As T+S As Reqd Comb Top (ft) (in.) (ft-k) (kip) (in^2) (in^2) (in^2) (in^2) 0.75 5.75 0.03 0.07 0.001 0.002 0.173 0.173 2 1.50 5.75 0.11 0.15 0.004 0.006 0.173 0.173 2 2.25 5.75 0.26 0.26 0.010 0.014 0.173 0.173 2 3.00 5.75 0.51 0.40 0.020 0.026 0.173 0.173 2 3.75 5.75 0.87 0.58 0.034 0.045 0.173 0.173 2 4.50 5.75 1.38 0.78 0.054 0.072 0.173 0.173 2 5.25 5.75 2.06 1.02 0.081 0.108 0.173 0.173 2 6.00 5.75 2.92 1.29 0.116 0.154 0.173 0.173 2 6.75 5.75 4.00 1.59 0.160 0.213 0.173 0.213 2 7.50 5.75 5.32 1.92 0.215 0.230 0.229 0.230 2 -------------------------------------------------------------------------------- Vertical Stem Reinforcement: Shear -Friction Steel Added at Stem Base (ACI 11 11.6), Avf = 0.056 in^2 Available Length for Hook Embedment into Footing = 8.25 in. Available Length for Straight Embedment into Stem = 88.00 in. Development Length Straight Hook Percent Spac. 50o Cut Off (in.) (in.) Develop. (in.) (in.) #4 14.40 8.40 98.21 10.25 90.00 #5 18.00 10.50 78.57 12.71 90.00 #6 21.60 12.60 65.48 15.03 90.00 #7 31.50 14.70 56.12 17.57 90.00 #8 40.00 16.80 49.11 18.00 90.00 #9 50.90 18.95 43.53 18.00 90.00 #10 64.52 21.34 38.67 18.00 90.00 #11 79.52 23.69 34.83 18.00 90.00 -------------------------------------------------------------------------------- Horizontal Stem Reinforcement: Area of steel for Shrinkage and Temp. Reinforcement = 0.192 in^2 -----Spacing, in.----- ------Total Bars------ I.F. Only EA. Face I.F. Only EA. Face #4 12.50 18.00 8.00 6.00 #5 18.00 18.00 6.00 6.00 #6 18.00 18.00 6.00 6.00 #7 18.00 18.00 6.00 6.00 #8 18.00 18.00 6.00 6.00 #9 18.00 18.00 6.00 6.00 #10 18.00 18.00 6.00 6.00 #11 18.00 18.00 6.00 6.00 8/22/2018 9:10 AM 6 of 8 LIMA TOE DESIGN: * Steel Design Comb. = 0.9D + 1.OW + 1.6H * Thickness Design Comb. = 0.9D + 1.OW + 1.6H * Available Length for Hook Embedment into Stem = 6.25 in. * Available Length for Straight Embed. into Toe = 10.00 in. --------------------- --- ---------- ------------------------------------------- d Mu Vlj Phi Vn s Flex. As Min. As T+S As Req'd (in.) (ft-k) "'(kip) (kip) (in^2) (in^2) (in ^2) (in^2) 7.75 2.51 2.71 0.073 0.097 0.238 0.238 -------------------------------------------------------------------------------- Development Length Straight Hook Percent � Spac. (in.) (in.) Develop". (in.) #4 14.40 8.405 .44 7.01 #5 18.00 10.50 - s 55.56 8.70 #6 21.60 12-`60 46.30 10.29 #7 31.50 14.70 31.75 9.62 #8 36.00-'` 16.80 27.78 11.08 #9 4,0-.`61 18.95 24.63 12.44 #10 '45.72 21.34 21.87 14.03 #111, 55.06 23.69 18.16 14.31 -------------------------------------------------------------------------------- HEEL DESIGN: * Steel Design Comb. = 1.2D + 1.6L + 1.6H + 0.5R * Thickness Design Comb. = 1.2D + 1.6L + 1.6H + 0.5R * Available Length for Straight Embedment into Toe = 18.00 in. * Available Length for Straight Embedment into Heel = 28.96 in. -------------------------------------------------------------------------------- d Mu Vu Phi Vn As Flex. As Min. As T+S As Req'd (in.) (ft-k) (kip) (kip) (in ^2) (in^2) (in^2) (in^2) 8.75 3.94 2.72 7.88 0.101 0.135 0.238 0.238 -------------------------------------------------------------------------------- Development Length Straight Hook Percent Spac. (in.) (in.) Develop. (in.) �. #4 14.40 8.40 100.00 10.10 f �,C- #5 18.00 10.50 100.00 15.66 #6 21.60 12.60 83.33 18.00 #7 31.50 14.70 57.14 17.32 #8 40.00 16.80 45.00 17.95 #9 50.90 18.95 35.37 17.86 #10 64.52 21.34 27.90 17.90 #11 79.52 23.69 22.63 17.83 8/22/2018 9:10 AM 7 of 8 9/9 LONGITUDINAL FOOTING REINFORCEMENT (TEMP & SHRINK ONLY): Spacing (in.) #4 10.10 #5 15.66 #6 22.22 #7 30.30 #8 39.90 #9 50.51 #10 64.14 #11 78.79 8/22/2018 9:10 AM CONTINUOUS SHEETING NAILED TO MUDSILL PER SHEAR WALL SCHEDULE SOLID BLOCKING A 24" O.C. (6) 16d NAILS EACH BLOCK 32" MIN. LENGTH WHERE JOIST PARALLEL TO WALL •A35 CLIP ON EACH SIDE OF BLOCKING OR JOIST o 16" O.C. - a 2-12d TOENAILS- _ I JOIST TO HAVE RIM MATERIAL ON EACH SIDE FOR CLIP 1 _1 N FINISH GRADE SLAB a ENTRY 04 BARS ® 18" O.C. FROM SLAB TO WALL AND E.W. IN SLAB DESIGN CRITERIA • (5) SACK CONCRETE • f, PSI 2500 • GRADE 60 IEBAR y PSI 60=0 • Ea FLUID PRESS . 40 LBS. / 5a FT. SAND/GRAVEL BACK --ILL • SEISMIC (814) PILE SUPPORTED. , NOTES: DO NOT BACKFILL UNTIL FLOOR SHEATHING IS NAILED. ANCHOR BOLTS: • MIN. 1/2" DIA. x 10" UN.O. • MIN 7 EMBEDMENT • USE 3" Sa WASHERS 4 NUTS • 1 BOLT WITHIN 12" OF ENDS 4 MIN. 2 BOLTS PER PIECE OF SILL PLATE. • MIN. 24" LAP • BAR SPLICE FOOTING DRAIN OUTFALL TO DAYLIGHT FLOOR JOISTS SEE PLAN FOR SIZE AND SPACING (2) 04 CONT. 3"-6" FROM TOP OF WALL ANCHOR BOLT SPACING P BOLTS , HORIZONTAL 5 MBAR SPACING O 10" O.C. VERTICAL REBAR 5 a 12" O.C. 2" CONCRETE COVER 8" FOUNDATION WALL WIDTH DOWEL5-04 REBAR • loll O.G. W/ HOOK OVERLAP VERTICAL REBAR loll MIN. 31/2" CONCRETE SLAB 6 MIL. (2) 04 REBAR HORIZONTAL CCONTJ Concrete Beam Design Report Concrete Beam Design Job: 30728 Designed By: RDH PE Beam ID: Basement Wall -Vert Steel Checked By: Date: 7/12/2019 11:57:08 AM Program: Concrete Beam Design 4.0 2/10 Page 1 Description: Basement Wall Code ACI (2011) Design Method Ultimate Strength Member Tvoe One-Wav Slab I Cross Section Shane Rectaneular Snan Data: Main Span Length 11.000 Ft Left End Support Pinned Right End Support Pinned Left Support Width 4.000 In Right Support Width 4.000 In Left Haunch Start Location Not Present Right Haunch Start Location Not Present Cross Section Data: Total Depth at Mid -Span 8.000 In Top Width at Mid -Span 12.000 In Material Data: Pc 2.500 K/Inz Flexural Reinforcing fy 60.000 K/InZ Concrete Density 144.000 Lb/Ft' Shear Reinforcing Ivy 60.000 K/In2 Concrete Tensile Strength 0.420 K/In' Stress Block, Beta 0.850 Dp.Cn1n Criteria: Bottom Covert Stirrup 3.000 In Top Cover to Stirrup 2.000 In Total Load Deflection Limit L/240.00 Live Load Deflection Limit L/360.00 Allow Cuts in Tension Zone N Check Crack Control Provisions Y ECHO OF LOAD INPUT DEAD LOAD LIVE LOAD WIND LOAD EARTHQUAKE LOAD ROOF LOAD Check Deflection: Yes Yes Yes Main Span # I Uniform Load: 0.000 K /Ft 0.000 K /Ft 0.000 K /Ft -0.088 K /Ft Distance to Begin: 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft Distance to End: 0.000 Ft 0.000 Ft 0.000 Ft 11.000 Ft # I Triangular Load: 0.000 K /Ft -0.440 K /Ft 0.000 K /Ft 0.000 K /Ft Distance to Begin: 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft Distance to End: 0.000 Ft 11.000 Ft 0.000 Ft 0.000 Ft Distance to Peak: 0.000 Ft 10.990 Ft 0.000 Ft 0.000 Ft CRITICAL SHEARS & MOMENTS Load Combination Dead Load: 1.400 x Dead Load Load Combination # 1: 1.200 x Dead Load + 1.600 x L + 0.500 x R Load Combination # 2: 1.200 x Dead Load + 1.000 x L + 1.600 x R Load Combination # 3: 1.200 x Dead Load + 0.800 x W + 1.600 x R Load Combination # 4: 1.200 x Dead Load + 1.000 x L + 1.600 x W + 0.500 x R DEAD LOAD LOAD COMB 1 LOAD COMB 2 LOAD COMB 3 LOAD COMB 4 No No No No Shear Left End: 0.000 K 1.292 K 0.807 K 0.000 K 0.807 K Moment Left End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Shear Right End: 0.000 K -2.580 K -1.613 K 0.000 K -1.613 K Moment Right End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Maximum Moment 5.470 K -Ft 3.418 K -Ft 3.418 K -Ft Located at: 1 6.351 Ft 6.351 Ft 6.351 Ft Max Deflection 0.000 In -0.050 In -0.050 In 0.000 In -0.050 In L:Project Fi1esHomes051 - 4063 Rainier Ave S063 7/12/2019 11:57:08 AM Rainier Ave SCapswall design-revl vert.rtf Concrete Beam Design Report 3/10 Page 2 Located at: 0.000 Ft 5.713 Ft 5.713 Ft 0.000 Ft 5.713 Ft Dead Part: 0.000 In 0.000 In 0.000 In 0.000 In Inflection Points: 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft Reaction Left End: 0.000 K 1.292 K 0.807 K 0.000 K 0.807 K Reaction Right End: 0.000 K 2.580 K 1.613 K 0.000 K 1.613 K Load Combination # 5: 1.200 x Dead Load + 1.000 x L + 1.400 x E + 0.200 x R Load Combination # 6: 0.900 x Dead Load + 1.600 x W Load Combination # 7: 0.900 x Dead Load + 1.400 x E Load Combination # 8: 1.200 x Dead Load - 0.800 x W + 1.600 x R Load Combination # 9: 1.200 x Dead Load + 1.000 x L -1.600 x W + 0.500 x R LOAD COMB 5 LOAD COMB 6 LOAD COMB 7 LOAD COMB 8 LOAD COMB 9 No No No No No Shear Left End: 1.485 K 0.000 K 0.678 K 0.000 K 0.807 K Moment Left End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Shear Right End: -2.290 K 0.000 K -0.678 K 0.000 K -1.613 K Moment Right End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Maximum Moment 5.252 K -Ft 1.863 K -Ft 3.418 K -Ft Located at: 6.069 Ft 5.500 Ft 6.351 Ft Max Deflection -0.109 In 0.000 In -0.020 In 0.000 In -0.050 In Located at: 5.652 Ft 0.000 Ft 5.500 Ft 0.000 Ft 5.713 Ft Dead Part: 0.000 In 0.000 lln 0.000 hi 0.000 In 0.000 In Inflection Points: 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft Reaction Left End: 1.485 K 0.000 K 0.678 K 0.000 K 0.807 K Reaction Right End: 2.290 K 0.000 K 0.678 K 0.000 K 1.613 K Load Combination # 10: 1.200 x Dead Load + 1.000 x L - 1.400 x E + 0.200 x R Load Combination # 11: 0.900 x Dead Load - 1.600 x W Load Combination # 12: 0.900 x Dead Load -1.400 x E LOAD COMB 10 LOAD COMB l I LOAD COMB 12 LOAD COMB 13 LOAD COMB 14 No No No Shear Left End: 0.130 K 0.000 K -0.678 K Moment Left End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Shear Right End: -0.935 K 0.000 K 0.678 K Moment Right End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Maximum Moment 1.639 K -Ft -1.863 K -Ft Located at: 7.071 Ft 5.500 Ft Max Deflection -0.109 hi 0.000 In -0.020 In Located at: 5.652 Ft 0.000 Ft 5.500 Ft Dead Part: 0.000 In 0.000 Li 0.000 In Inflection Points: 0.000 Ft 0.000 Ft 0.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft Reaction Left End: 0.130 K 0.000 K -0.678 K Reaction Right End: 0.935 K 0.000 K -0.678 K SECTION DESIGN INFORMATION SECTION FLEXURAL DESIGN Mid -Span Region: Cross -Section Information: Total Depth : 8.000 In Distance to Centroid As : 4.69 In Top Width : 12.000 In Distance to Centroid A's : 2.31 In For Design Moment, Mu: 5.470 K -Ft Required As: 0.308 In2 (p : 0.005) Required A's : 0.000 In ( : 0.000) Provided As : 0.310 In2 (p : 0.006) Provided A's : 0.000 In2 ( : 0.000) L:Project FilesHomes051 - 4063 Rainier Ave S063 7/12/2019 11:57:08 AM Rainier Ave SCapswall design-revl vert.rtf Concrete Beam Design Report 4/10 Page 3 Reduction Factor, Phi : 0.90 Moment Capacity, *Mn: 6.030 K -Ft Gross Area : 96.000 I112 Gross Moment of Inertia: 512.000 In Neutral Axis Location : 4.00 In N (Es/Ec) : 10.17 Modulus, Ec : 2,851.20 K /In2 Cracked Moment of Inertia : 44.954 In2 Neutral Axis Location : 6.67 In Cracking Moment: 4.000 K -Ft Mid -Span Region: Cross -Section Information: Total Depth : 8.000 In Distance to Centroid As : 5.69 In Top Width: 12.000 In Distance to Centroid A's : 2.31 In For Design Moment, Mu : -1.863 K -Ft Required As : 0.173 In2 (p : 0.003) Required A's : 0.000 In ( : 0.000) Provided As : 0.310 In (p : 0.005) Provided A's : 0.000 In (p : 0.000) Reduction Factor, Phi : 0.90 Moment Capacity, *Mn : -7.425 K -Ft Gross Area: 96.000 In Gross Moment of Inertia: 512.000 In2 Neutral Axis Location : 4.00 In N (Es/Ec) : 10.17 Modulus, Ec : 2,851.20 K /In2 Cracked Moment of Inertia : 68.785 I112 Neutral Axis Location: 6.51 In Cracking Moment : 4.000 K -Ft * Indicates That Nominal Resistance Includes Appropriate Phi Factor BOTTOM BARS Mid -Span Region: Design Moment, Mu 5.47 K-Ft As Required 0.308 In As Provided 0.310 In2 d 4.6881 Bar Size #5 Number of Layers I 1 I Layer Spacing 0.00111 Number of Bars 1 Bars in Lower Layer I 1 I Ld 18.00 In At Left Support: Percent of Bars Continuing into Support 100 Suggested Bar Cutoff (from Centerline of Suppo_r_t_)_____j 0.00 In At Right Support: Percent of Bars Continuing into Support 100 Suggested Bar Cutoff (from Centerline of Support) 0.00111 TOP BARS - MID SPAN *** NOTE: Negative Moment Extends Across Span *** Design Moment, Mu 1 -1.86 K-Ft I As Required 1 0.173 In 1 As Provided 1 0.310 In 1 d Id : 5.688 In Bar Size #5 Number of Layers I 1 I Layer Spacing 0.00 In Number of Bars I Bars in Lower Layer I 1 I Ld 18.00 In MAXIMUM DEFLECTIONS Span Load Comb Short Total Long Total Max Allow Short Live Load Max Allow Ieffective In In In In In In' MAIN Dead 0.000 0.550 OK 512.00 1 -0.050 -0.075 0.550 OK -0.050 0.367 OK 512.00 2 -0.050 -0.075 0.550 OK -0.050 0.367 OK 512.00 3 0.000 0.000 0.550 OK 0.000 0.367 OK 512.00 4 -0.050 -0.075 0.550 OK -0.050 0.367 OK 512.00 5 -0.109 -0.163 0.550 OK -0.109 0.367 OK 328.16 6 0.000 0.000 0.550 OK 0.000 0.367 OK 512.00 7 -0.020 -0.030 0.550 OK -0.020 0.367 OK 512.00 8 0.000 0.000 0.550 OK 0.000 0.367 OK 512.00 L:Project Fi1esHomes051 - 4063 Rainier Ave S063 7/12/2019 11:57:08 AM Rainier Ave SCapswall design-revl vert.rtf Concrete Beam Design Report 5/10 Page 4 9 -0.050 -0.075 0.550 OK -0.050 0.367 OK 512.00 10 -0.109 -0.163 0.550 OK -0.109 0.367 OK 328.16 11 0.000 0.000 0.550 OK 0.000 0.367 OK 512.00 12 -0.020 -0.030 0.550 OK -0.020 0.367 OK 512.00 SHEAR DESIGN - MAIN SPAN --------------------- Left Side --------------------- --------------------- Right Side -------------------- Number @ Spacing Al Number @ Spacing Al In In2 Spacing starts from face of support .... None Re aired None Required L:Project FilesHomes051 - 4063 Rainier Ave S063 7/12/2019 11:57:08 AM Rainier Ave SCapswall design-revl vert.rtf Concrete Beam Design Report Concrete Beam Design Job: 30728 Designed By: RDH PE Beam ID: Basement Wall Horizontal Steel Checked By: Date: 7/12/2019 12:02:13 PM Program: Concrete Beam Design 4.0 Description: Basement Wall 6/10 Page 1 Code ACI (2011) Design Method Ultimate Strength Member Type One -Way Slab Cross Section Shape Rectangular Cnan Dnfnr Main Span Length 13.000 Ft Left End Support Fixed Right End Support Fixed Left Support Width 4.000 In Right Support Width 4.000 In Left Haunch Start Location Not Present Right Haunch Start Location Not Present Cross Section Data: Total Depth at Mid -Span 8.000 In Top Width at Mid -Span 12.0001 Material Data: fc 1 2.500 K/In2 Flexural Reinforcing fy 60.000 K/In2 Concrete Density 144.000 Lb/Ft' Shear Reinforcing fvy 60.000 K/In' Concrete Tensile Strength 0.420 K/In' Stress Block, Beta 0.850 Design Criteria: Bottom Cover to Stirrup 3.000 In Top Cover to Stirrup 1.500 In Total Load Deflection Limit L/240.00 Live Load Deflection Limit L/360.00 Allow Cuts in Tension Zone N Check Crack Control Provisions Y ECHO OF LOAD INPUT DEAD LOAD LIVE LOAD WIND LOAD EARTHQUAKE LOAD ROOF LOAD Check Deflection: Yes Yes Yes Main Span # 1 Uniform Load: 0.000 K /Ft -0.360 K /Ft 0.000 K /Ft 0.088 K /Ft Distance to Begin: 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft Distance to End: 0.000 Ft 13.000 Ft 0.000 Ft 13.000 Ft CRITICAL SHEARS & MOMENTS Load Combination Dead Load: 1.400 x Dead Load Load Combination # 1: 1.200 x Dead Load + 1.600 x L + 0.500 x R Load Combination # 2: 1.200 x Dead Load + 1.000 x L + 1.600 x R Load Combination # 3: 1.200 x Dead Load + 0.800 x W + 1.600 x R Load Combination # 4: 1.200 x Dead Load + 1.000 x L + 1.600 x W + 0.500 x R DEAD LOAD LOAD COMB 1 LOAD COMB 2 LOAD COMB 3 LOAD COMB 4 Shear Left End: 0.000 K 3.744 K 2.340 K 0.000 K 2.340 K Moment Left End: 0.000 K -Ft -8.112 K -Ft -5.070 K -Ft 0.000 K -Ft -5.070 K -Ft Shear Right End: 0.000 K -3.744 K -2.340 K 0.000 K -2.340 K Moment Right End: 0.000 K -Ft -8.112 K -Ft -5.070 K -Ft 0.000 K -Ft -5.070 K -Ft Maximum Moment 4.056 K -Ft 2.535 K -Ft 2.535 K -Ft Located at: 6.500 Ft 6.500 Ft 6.500 Ft Max Deflection 0.000 In -0.040 In -0.040 In 0.000 In -0.040 In Located at: 0.000 Ft 6.500 Ft 6.500 Ft 0.000 Ft 6.500 Ft Dead Part: 0.000 In 0.000 In 0.000 In 0.000 hr Inflection Points: 0.000 Ft 2.747 Ft 2.747 Ft 0.000 Ft 2.747 Ft 13.000 Ft 10.253 Ft 10.253 Ft 13.000 Ft 10.253 Ft Reaction Left End: 0.000 K 3.744 K 2.340 K 0.000 K 2.340 K L:Project Fi1esHomes051 - 4063 Rainier Ave S063 7/12/2019 12:02:13 PM Rainier Ave SCapswall design-revl.rtf Concrete Beam Design Report 7/10 Page 2 Reaction Right End: 1 0.000 K 1 3.744 K 1 2.340 K 1 0.000 K 1 2.340 K Load Combination # 5: 1.200 x Dead Load + 1.000 x L + 1.400 x E + 0.200 x R Load Combination # 6: 0.900 x Dead Load + 1.600 x W Load Combination # 7: 0.900 x Dead Load + 1.400 x E Load Combination # 8: 1.200 x Dead Load - 0.800 x W + 1.600 x R Load Combination # 9: 1.200 x Dead Load + 1.000 x L - 1.600 x W + 0.500 x R LOAD COMB 5 LOAD COMB 6 LOAD COMB 7 LOAD COMB 8 LOAD COMB 9 Shear Left End: 1.539 K 0.000 K -0.801 K 0.000 K 2.340 K Moment Left End: -3.335 K -Ft 0.000 K -Ft 1.735 K -Ft 0.000 K -Ft -5.070 K -Ft Shear Right End: -1.539 K 0.000 K 0.801 K 0.000 K -2.340 K Moment Right End: -3.335 K -Ft 0.000 K -Ft 1.735 K -Ft 0.000 K -Ft -5.070 K -Ft Maximum Moment 1.667 K -Ft -0.868 K -Ft 2.535 K -Ft Located at: 6.500 Ft 6.500 Ft 6.500 Ft Max Deflection -0.024 In 0.000 In 0.008 In 0.000 In -0.040 In Located at: 6.500 Ft 0.000 Ft 6.500 Ft 0.000 Ft 6.500 Ft Dead Part: 0.000 In 0.000 In 0.000 In 0.000 In 0.000 In Inflection Points: 2.747 Ft 0.000 Ft 2.747 Ft 0.000 Ft 2.747 Ft 10.253 Ft 13.000 Ft 10.253 Ft 13.000 Ft 10.253 Ft Reaction Left End: 1.539 K 0.000 K -0.801 K 0.000 K 2.340 K Reaction Right End: 1.539 K 0.000 K -0.801 K 0.000 K 2.340 K Load Combination # 10: 1.200 x Dead Load + 1.000 x L - 1.400 x E + 0.200 x R Load Combination # 11: 0.900 x Dead Load -1.600 x W Load Combination # 12: 0.900 x Dead Load - 1.400 x E LOAD COMB 10 LOAD COMB 11 LOAD COMB 12 LOAD COMB 13 LOAD COMB 14 Shear Left End: 3.141 K 0.000 K 0.801 K Moment Left End: -6.805 K -Ft 0.000 K -Ft -1.735 K -Ft Shear Right End: -3.141 K 0.000 K -0.801 K Moment Right End: -6.805 K -Ft 0.000 K -Ft -1.735 K -Ft Maximum Moment 3.403 K -Ft 0.868 K -Ft Located at: 6.500 Ft 6.500 Ft Max Deflection -0.024 In 0.000 In 0.008 In Located at: 6.500 Ft 0.000 Ft 6.500 Ft Dead Part: 0.000 In 0.000 In 0.000 In Inflection Points: 2.747 Ft 0.000 Ft 2.747 Ft 10.253 Ft 13.000 Ft 10.253 Ft Reaction Left End: 3.141 K 0.000 K 0.801 K Reaction Right End: 3.141 K 0.000 K 0.801 K SECTION DESIGN INFORMATION SECTION FLEXURAL DESIGN Mid -Span Region: Cross -Section Information: Total Depth : 8.000 In Distance to Centroid As : 4.75 In Top Width : 12.000 In Distance to Centroid A's : 1.75 In For Design Moment, Mu: 4.056 K -Ft Required As : 0.219 In (p : 0.004) Required A's : 0.000 In (p : 0.000) Provided As : 0.400 In (p : 0.007) Provided A's: 0.000 In (p : 0.000) Reduction Factor, Phi : 0.90 Moment Capacity, *Mn : 7.703 K -Ft Gross Area: 96.000 In Gross Moment of Inertia: 512.000 In2 Neutral Axis Location : 4.00 In N (Es/Ec) : 10.17 Modulus, Ec : 2,851.20 K /In2 Cracked Moment of Inertia : 56.470 In2 Neutral Axis Location : 6.51 In Cracking Moment: 4.000 K -Ft L:Project FilesHomes051 - 4063 Rainier Ave S063 7/12/2019 12:02:13 PM Rainier Ave SCapswall design-revl.rtf Concrete Beam Design Report At Left Support: Cross -Section Information: 8/10 Page 3 Total Depth : 8.000 In Distance to Centroid As : 6.25 In Top Width: 12.000 In Distance to Centroid A's : 1.75 In For Design Moment, Mu: -7.496 K -Ft Required As : 0.281 In2 (p : 0.004) Required A's : 0.000 In2 (p : 0.000) Provided As : 0.400 I112 (p : 0.005) Provided A's : 0.000 In2 (p : 0.000) Reduction Factor, Phi : 0.90 Moment Capacity, *Mn : -10.403 K -Ft Gross Area: 96.000 In2 Gross Moment of Inertia: 512.000 In2 Neutral Axis Location : 4.00 In N (Es/Ec) : 10.17 Modulus, Ec : 2,851.20 K /In2 Cracked Moment of Inertia : 103.824 In2 Neutral Axis Location : 6.25 In Cracking Moment: 4.000 K -Ft Mid -Span Region: Cross -Section Information: Total Depth : 8.000 hi Distance to Centroid As : 6.25 In Top Width: 12.000 In Distance to Centroid A's : 1.75 In For Design Moment, Mu: -8.112 K -Ft Required As : 0.306 In2 (p : 0.004) Required A's : 0.000 In2 (p: 0.000) Provided As : 0.400 In2 (p : 0.005) Provided A's: 0.000 In2 (p: 0.000) Reduction Factor, Phi : 0.90 Moment Capacity, *Mn: -10.403 K -Ft Gross Area : 96.000 In2 Gross Moment of Inertia: 512.000 I112 Neutral Axis Location : 4.00 In N (Es/Ec) : 10.17 Modulus, Ec : 2,851.20 K /h12 Cracked Moment of Inertia : 103.824 In2 Neutral Axis Location : 6.25 In Cracking Moment: 4.000 K -Ft At Right Support: Cross -Section Information: Total Depth : 8.000 In Distance to Centroid As : 6.25 In Top Width: 12.000 In Distance to Centroid A's : 1.75 In For Design Moment, Mu : -7.496 K -Ft Required As : 0.281 In2 (p : 0.004) Required A's : 0.000 h12 (p : 0.000) Provided As : 0.400 In2 (p : 0.005) Provided A's: 0.000 In2 ( : 0.000) Reduction Factor, Phi : 0.90 Moment Capacity, *Mn : -10.403 K -Ft Gross Area: 96.000 In2 Gross Moment of Inertia : 512.000 In2 Neutral Axis Location : 4.00 In N (Es/Ec) : 10.17 Modulus, Ec : 2,851.20 K /In2 Cracked Moment of Inertia: 103.824 In2 Neutral Axis Location : 6.25 In Cracking Moment: 4.000 K -Ft * Indicates That Nominal Resistance Includes Appropriate Phi Factor BOTTOM BARS Mid -Span Region: Design Moment, Mu 4.06 K-Ft As Required 0.219 hie As Provided 0.400 In2 d 4.7501 L:Project FilesHomesOS1 - 4063 Rainier Ave S063 7/12/2019 12:02:13 PM Rainier Ave SCapswall design-revl.rtf NWAUI Concrete Beam Design Report Page 4 Bar Size #4 Number of Layers I Layer Spacing 0.00 In Number of Bars 2 Bars in Lower Layer 2 1 Ld 14.40 In At Left Support: Design Moment, Mu 1.60 K-Ft As Required 0.216 In As Provided 0.400 In2 d 4.750 In Bar Size #4 Number of Layers 1 Layer Spacing 0.00 In Number of Bars 2 Bars in Lower Layer 2 Ld 14.40 In ***Anchor Bars Percent of Bars Continuing into Support 1 100 1 Suggested Bar Cutoff (from Centerline of Support) I0.00 In At Right Support: Design Moment, Mu 1.60 K-Ft As Required 0.216 I112 As Provided 0.400 In d 4.7501n Bar Size 44 Number of Layers 1 Layer Spacing 0.00 In Number of Bars 2 Bars in Lower Layer 2 Ld 14.40 In ***Anchor Bars Percent of Bars Continuing into Support 1 100 1 Suggested Bar Cutoff (from Centerline of Support) 1 0.00 In TOP BARS - LEFT SUPPORT Design Moment, Mu 1 -7.50 K-Ft I As Required 1 0.281 I112 1 As Provided 1 0.400 In 1 d 1 6.250 In Bar Size #4 Number of Layers 1 Layer Spacing 0.00 In Number of Bars 2 Bars in Lower Layer 2 Ld 14.40 In Suggested Bar Cutoff 0.00111 TOP BARS - MID SPAN *** NOTE: Negative Moment Extends Across Span *** Design Moment, Mu -8.11 K-Ft I As Required 0.3061n2 As Provided 0.400 In2 d d : 6.250 In Bar Size #4 Number of Layers 1 Layer Spacing I 0.00 In Number of Bars 2 Bars in Lower Layer 2 Ld 1 14.40 In TOP BARS - RIGHT SUPPORT Design Moment, Mu 1 -7.50 K-Ft I As Required 1 0.281 In2 I As Provided 1 0.400 In2 1 d 1 6.250 In Bar Size #4 Number of Layers 1 Layer Spacing 0.00111 Number of Bars 2 Bars in Lower Layer 2 Ld 14.40 In Suggested Bar Cutoff 0.00 In MAXIMUM DEFLECTIONS Span Load Comb Short Total Long Total Max Allow Short Live Load Max Allow Ieffective In In In In In In' MAIN Dead 0.000 0.650 OK 512.00 1 -0.040 -0.060 0.650 OK -0.040 0.433 OK 408.14 2 -0.040 -0.060 0.650 OK -0.040 0.433 OK 408.14 3 0.000 0.000 0.650 OK 0.000 0.433 OK 512.00 4 -0.040 -0.060 0.650 OK -0.040 0.433 OK 408.14 5 -0.024 -0.036 0.650 OK -0.024 0.433 OK 512.00 6 0.000 0.000 0.650 OK 0.000 0.433 OK 512.00 7 0.008 0.012 0.650 OK 0.008 0.433 OK 512.00 8 0.000 0.000 0.650 OK 0.000 0.433 OK 512.00 9 -0.040 -0.060 0.650 OK -0.040 0.433 OK 408.14 10 -0.024 -0.036 0.650 OK -0.024 0.433 OK 512.00 11 0.000 0.000 0.650 OK 0.000 0.433 OK 512.00 12 0.008 0.012 0.650 OK 0.008 0.433 OK 512.00 L:Project Fi1esHomes051 - 4063 Rainier Ave S063 7/12/2019 12:02:13 PM Rainier Ave SCapswall design-revl.rtf Concrete Beam Design Report SHEAR DESIGN - MAIN SPAN 10/10 Page 5 --------------------- Left Side --------------------- --------------------- Right Side --------------------- Number @ Spacing Al Number @ Spacing Al In2 In2 Spacing starts from face of support .... None Required None Required L:Project FilesHomes051 - 4063 Rainier Ave S063 7/12/2019 12:02:13 PM Rainier Ave SCapswall design-revl.rtf F-1 � WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN Thuesen-510 8th Ave N rev 2019.wwa WoodWorksO Sizer 11.1.1 Oct. 15, 2019 09:49:54 Concept Mode: Beam View Floor 1: 1' 41 65' 24 _ 56, 32 : 57' 33 51' g : : : : 48' 38 10 43'_6" 95i��®"' \ -. '_owl, -. LO'_. _. 40' 1 8 - : 37' 27 <w : J6' 17 �' .. .*�;P e ova : - - 35' 23 �# _ .. _ 33' 13 32 12 27' 2 - 26' pc7 30 : 24' pc8 ,)9 21 d1 19 pc5a : e 11 pc7a : -. 15' 20 12 36 PC2- + pc5 C6- c6 14 .. TBT TB3 TB5 -. 7' 39 7B2 TB4 5' 15 40 - - 2' AT T A BC)V K%BB3AL-AV U UARYF9AX AGX NAYAW AI OAHZ C AZS' BD ABAUH AO (AN B R SI G AC E AD\B AAAF JAE 0' 2' 4' 5'-6"7' 8' 9' 11' 13' 18' 20'-6' 24' 26' 28'-6" 32' 34' 36' 38'-6" 42' 44' 47'-6" 50' 52' 54'-6" 59' 65'-6" 70' 74' 86' 90'-6" 9'-6"-6"2'-6" 17' 19"0' 22' 25' 27'-6" 31' 33' 37'-6" 40' 43' 46' 48' 54' 73' 87'-6" 91'-6" 2/11 SHEARWALL PER PLAN ANCHOR E3OLT6 PER PLAN FIN. GR.� ----� 2-05 a Top and 04 6 IS" oc HORIZ m ii• i #4 9 9" oc VERT z 1-3 STIRRUPS - 6"oc x 24" I- ' co EA SIDE OF PILE AT CORNERS, 36" IN CENTER OF GRADE E3EAM. PILE CAP PER DETAIL 5/ tf' 12'1 (2) #'4 GR. 60 TOP 4 BOTTOM, LAP BAR5 26" AT SPLICES " CLR PIN PILES PER PLAN 1 PERIMETER GRADE BEAM NOT TO SCALE F-I � Thuesen-510 8th Ave N rev 2019.wwa WoodWorks® Sizer WoodWorksOO Concept Mode: Reactions at Base of Structure View Floor 1: 1' 41 16 37 28_. c122 c37 c137 c140 _c141_ c38 c117 C: c88 118 S 320 L 1845 S 1 D 1 D 24.. 3D. _. ._1563 _.... 1181D 25 S 215 D -34 U c108 w63 32 33 2384S _. _.......... 100S _... w121506 D 65 D c93 S 1109 S c116 86 c87 3180 S 1 D20 L 1 D 38 c109 1375 S 10 839 D 550 S 330 D c110) c20 c15 c134 w15 22 50 S 659 L, . 480 L - 486 L_ .... . 630 L _ ..... ........ ...... ........ .... c84 25 332 D, 192 D 175 D 175 D 230 D LbZ3 S 1552 D 139 S 839 D 27. _ _ c27 26 c25 w81365 D �198 D. 357 L 381 L 60 L 551 S c42 L 119 D 125 D 19 D 331 D 1950 S 187 S 1315 D 120 D c22 c24 11 c10 c73 c18 w7 c128 N�56 4 60 L 60 L 1220 L 1340 -54 S 864 L 83 S 1136 L Fi 19 D 19 D 393 D. 110 S -34 D 1960 S 50 t177 D4891 S 12 — c23c21 ` w c136 c13': c12 358 D 498 D\ -89 U 1568 D 82 D 3478 D 2 312 U8 L -104 S - 1025 L 953 L 4141 D 52 SI1 D 3164 D 14 S 36 S 30 _..... _. 61 D --168 U ._ 355 D 362 D. _..... _...... Lt _.. _..... ie }�_... _. CIA t� c144 c148 c147 log, 1 29 34 ,�, - - ` r g 1169 L 2543 L _ 4722 L 7L�744 34 L P1 -7 S 45 S -189 S 944S 21 - -- \� ,..3710D 5513D 8114D ',246D 19 -. - - 20 36 2256 L .. 9504 L 35 P2 P3 97 S 160 .'c143 8 P9 P1 - 2087 L 8033 L 2469 L 550 L 4877 L 5771 L 29 6 L275 L 3237 S 6335 S 3218 S 313 11778 S 927 S 32 8 S 14 - 3237D 6335D - .:3218D - -" li 16760D 9272D 716 D2271D 39 �P11 P12 1,13 15 40 _._. 1800 L _. _.... 2640 L _ 840 L _..... 1875 D 3065 D 1640 D 18 AT T A BCQ V K VBB,IBA,L AAV- U M AR Y F D AX AG X N AYO AW Al O AH Z C AZS' BD AM AU H AO CAN B R S I G 0' 2' 4' 6' 7' 8' 9' 10' 1 V 12' 13' 17' 18' 19' 20' 21' 22' 24' 25' 26' 27'-6" 31' 32' 33' 34' 36' 38'-6" 40' 42' 43' 44' 46' 47'-6" 50' 52' 54'-6" 59 5'-6" 9'-6")'-6" 12'-6' 20'-6" 27' 28'6" 37'-6"' 48' 54' Pile Analysis Column Footing # DL 2" 3" 4° Pile Capacities 4,000 12,000 20,000 lb Design DL+ Live Load LL SL WL DL+LL DL+SL LL+SL+WL) (lb) 188 10443 11445 19700 18730 10443 D87 1551 5602 5066 6244 2729 D33 1503 14774 8244 13893 8033 469 1358 5997 4886 6398 2870 942 938 5648 3644 5616 2942 504 1601 15438 7535 14263 9504 0 0 0 0 870 1778 11627 8535 11743 4986 750 786 15011 10047 14163 5750 973 3175 9258 9460 10896 4611 800 949 4245 3394 4507 2062 434 949 6034 4549 6137 2537 486 4400 1914 3779 2486 944 2468 3620 5144 5235 2559 550 3683 3133 3546 550 511 19 6443 4851 6055 1611 275 28 2546 2299 2498 275 204 23 7333 5152 6799 2204 722 12836 8114 11656 4722 543 8056 5513 7420 2543 Pile Cap Analysis V (lb) M (ft.lb) PC1 11763 12753 PC2 9274 10888 8036 13299 pc5a` 4080 8019 i 11 R C6{�����, 8017 13359 P,, PC7 8489 14734 8102 10063 Design Load (lb) 19700 6244 14774 6398 5648 15438 0 11743 15011 10896 4507 6137 4400 5235 3683 6443 2546 7333 12836 8056.0 Pile Dia 4 in 3 in 4 in 3 in 3 in 4 in 2 in 3 in 4 in 3 in 3 in 3 in 3 in 3 in 2 in 3 in 2 in 3 in 4 in 3 in 4h COMPANY Design Build Services, Inc. PROJECT 510 Bill Ave N - Lot 2 120th SE Monroe, WA 98272 510 Bih Ave N Edmonds, WA 98020 WoodWorks' (360) 59 (360)793-9659 Thuesen Custom Homes Oct. 15, 2019 09:42 PC4.-b I Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads Load Type Distribution Pat- tern Location IfI Start End Magnitude Start End Unit 1 c71 Dead Point Ito 3.96 432 lbs 2 c71 snow Point Yes 3.96 635 lbs 3 w24 Dead partial UDL No 0.9E 5.96 285.7 285.7 plf 4 w24 Live Partial UDL Yes 0.96 5.96 600.0 600.0 plf 5 w24 Snow Partial UDL Yes 0.96 5.96 141.0 141.0 plf 6 c4 Dead Point tto 5.96 601 lba 7 c4 Live Point Yea 5.96 1800 lbs 8 c5 Dead Point it 11.79 1426 lbs 9 c5 Live Point Yes 11.79 3000 lbs 10 c5 Snow Point Yes 11.79 758 1ba ll jl29 Dead Full UDL IT. 122.2 plf 12 jl29 Live Full UDL Yes 360.0 plf Load13 Dead Full UDL ito 250.0 plf self-wei ht Dead Full UDL I No 1 1 42.3 1pif Maximum Reactions (lbs) and Bearing Lengths (in) : I T-0.5" Unfactored: Dead 2775 5229 1211 Live 3560 6874 3620 Snow Factored: 713 992 537 Total Bearing: 6356 12103 4831 Length 11.50 1.50 11.50 Plin re 'd 0.88 1.50" 0.67 "Minimum bearing length governed by the required width of the supporting member. Maximum reaction on at least one support is from a different load combination than the critical one for bearing design, shown here, due to Kd factor. See Analysis results for reaction from critical load combination. pc4 Timber -soft, D.Fir-L, No.2, 12x16 (11-1/2"x15-1/2") Supports: 1,3 -Timber-soft Beam, D.Fir-L No.2; 2-Timber-soft Column, D.Fir-L No.2; Total length: IT-0.5"; Clear span: T-6.0", V-6.0"; volume = 16.1 cu.ft.; Beam and stringer Lateral support: top= full, bottom= at all supports; Analysis vs. Allowable Stress and Deflection using Nos 2015: Criterion Analysis Value Desi rt Value Unit Mal sis/Desi n Sheaf fv =54 Fv' = 170 psi fv I = 0.31 Bending(+) fb = 253 Fb' = 847 psi fb/Fb' = 0.30 Bending(-) fb = 211 Fb' = 847 psi fb/Fb' = 0.31 Dead Defl'n 0.11 = <1/999 Live Defl'a 0.01 = <L/999 0.25 = L/360 in 0.04 Total Defl'n 0.02 = <L/999 0.38 = L/240 in 0.05 Additional Data: FACTORS: F/E(psi)CD CPS Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 170 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 875 1.00 1.00 1.00 1.000 0.969 1.00 1.00 1.00 1.00 - 5 Fb'- 875 1.00 1.00 1.00 1.000 0.969 1.00 1.00 1.00 1.00 - 2 Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 - 5 CRITICAL LOAD COMBINATIONS: Shear : LC 42 = D+L, V max = 7512, V design = 6363 lbs Bending(+): LC N5 = D+L (pattern: L I, M = 9712 lbs-ft Bending)-): LC 42 = D+L, 14 = 10077 lbs-ft Deflection: LC #5 = (live) LC 45 = (total) D=dead L=live S=snow 4r=wind I -imp act Lr=roof live L-concentrated E=earthquake All LC's a e listed in the Analysis output Load Patterns: s=S/2, X=L+S or L+Lr, - o pattern load in this span Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 4639e06 1b-in2 "Live" deflection = Deflection from all non -dead loads (live, wind, snow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. Design Notes: i. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2015). the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2/3 of 2 span beams and to the full length of cantilevers and other spans. COMPANY Design Build Services, Inc. I PROJECT 510 8th Ave N - Lot 2 R 0 SE Monroe, WA 98272 510 8th Edmonds, WA 98020 ® ® Works (360) 7 3-9h 59 (360) 793-9659 Thuesen Custom Homes I Oct. 15, 2019 09:46 pc5r.wwb SOMVAREFOR WOOD DESIGN Design Check Calculation Sheet Wood Works Sizer 11A.1 Loads: Load Type Distribution Pat- tern Location tftl Stazt End Magnitude Start End Unit 1.33 Dead Point 4.04 1612 lb. 2 c33 Live Point 4.11 1850 lb 3 c33 Snow Point 4.01 1424 lbs 4 j143 Dead Full UDL 629.0 plf 5 j143 Live Full UDL 211'0 plf Load6 Dead Full UDL 250.0 plf Self -weight Dead Fu11 UDL 42.3 plf Maximum Reactions (lbs) and Bearing Lengths (in) 4'-1.32" Unfacto zed: Dead 1886 3511 Live 563 2417 Snow 1424 Facto zed: Total 2450 6392 Hearing: Length 0.50* 0.82 rlin z 'd 0.50* 0.82 Minimum bearing length setting used: 1/2" for end supports pc5 Timber -soft, D.Fir-L, No.2, 12x16 (11-1/2"x15-1/2") Supports: All - Timher-soft Column, D.Fir-L No.2 Total length: 4'-1.32"; Clear span: 4'; volume = 5.1 cu.ft.; Beam and stringer Lateral support: top= full, bottom= at supports; Analysis vs. Allowable Stress and Deflection using Nos 2016 : Criterion Analysis Value Desi Value Unit Anal s's/Desi Shear fv = 7 Fv' 170 psi fv Fv' = On04 Bending(+) to = 69 Eb' = 847 psi fb/Eb' = 0.08 Dead Def1'n 0.00 = <L/999 Live Defl'n negligible Total Defl'n 0.00 = <L/999 0.20 = L/240 0.01 Additional Data: FACTORS: F/E(psi)CD C6t Ct CL CF Cfu Cr Cfrt Ci Cc LC# Fv' 170 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 875 1.00 1.00 1.00 1.000 0.969 1.00 1.00 1.00 1.00 - 2 Fop' 121 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 - 2 CRITICAL LOAD COMBINATIONS: Shear : LC 12 = D+L, V m = 2426, V design = 850 lb. Bending(+): LC 42 = D+L, It T 2459 To -ft Deflection: LC #2 = D+L (live) LC #2 = D+L (total) D=dead L=live S=snow t9=wind I=impact Lr=roof live Lc=concentrated E=earthqua M.e All LC's are listed in the Analysis output Load combinations: ASCP. 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 4639e06 lb-in2 "Live. deflection = Deflection from all n n-dead loads (live, wind, sn ow...l Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflaction. Design Notes: 1. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. COMPANY Design Build Services, Inc. PROJECT 510 8th Ave N - Lot 2 0thWA 510 8th Ave N WoodWorks' 9 7 Monroe, WA 98272 Monroe, , Edmonds, WA 98020 (360) 793-9659 Thuesen Custom Homes SOFTWARE FOR WOOD DESIGN Oct. 15, 201909:47 pc5ar.wwb Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads: Load Type Distribution Pat- tern Location [ft] Start End Magnitude Start End Unit 1 pc4 Dead Point 9.04 987 lbs 2 pc4 Live Point 9.04 2032 lbs 3 pc4 Snow Point 9.04 469 lbs Load4 Dead Full UDL 250.0 plf Self -weight Dead Full UDL 42.3 plf Maximum Reactions (lbs) and Bearing Lengths (in) : 11'-1.07" a Unfactored: Dead 1800 2426 Live 372 1659 Snow 86 383 Factored: Total 2173 4086 Bearing: Length 0.50` 0.57 Min req'd 0.50* 0.57 'Minimum bearing length setting used: 1/2" for end supports pc5a Timber -soft, D.Fir-L, No.2, 12x16 (11-1/2"x15-1/2") Supports: All - Timber -soft Column, D.Fir-L No.2 Total length: 1 V-1.07"; Clear span: I V; volume = 13.7 cu.ft.; Beam and stringer Lateral support: top= full, bottom= at supports; Analysis vs. Allowable Stress and Deflection using Nos 2016 : Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 31 Fv' = 170 psi fv/Fv' = 0.18 Bending(+) fb = 209 Fb' = 847 psi fb/Fb' = 0.25 Dead Defl'n 0.03 = <L/999 Live Defl'n 0.01 = <L/999 0.37 = L/360 in 0.03 Total Defl'n 0.04 = <L/999 0.55 = L/240 in 0.07 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 170 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 875 1.00 1.00 1.00 1.000 0.969 1.00 1.00 1.00 1.00 - 2 Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 - 2 CRITICAL LOAD COMBINATIONS: Shear : LC 42 = D+L, V max = 4080, V design = 3695 lbs Bending(+): LC #2 = D+L, 1.1 = 8019 lbs-ft Deflection: LC #2 = D+L (live) LC #2 = D+L (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 4639e06 lb-in2 "Live" deflection = Deflection from all non -dead loads (live, wind, snow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. Design Notes: 1. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. COMPANY Design Build Services, Inc. PROJECT 510 8lh Ave N - Lot 2 20th59 SE Monroe, WA 98272 510 8th Ave N Edmonds, WA 98020 WoodWorks' (360) 793-9659 (360) 7 Thuesen Custom Homes Oct. 15, 2019 09:47 PC6r.wwb SOF7iYAREFOR N'OOD DESIGN Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads: Load Type Distribution Pat- tern Location 11tI Start End magnitude Start End Unit 1 w28 Dead Partial UDL Ito 11.43 13.93 205.4 205.4 Rif 2 w28 Live Partial UDL Yes 11.43 13. 93 449.1 449.1 plf 3 w28 Snow Partial UDL Yes 11.43 13. 93 119.7 119.7 plf 4 c6 Dead Point Ito 2.57 1755 lbs 5 c6 Live Point Yes 2.57 3528 ibs 6 c6 Snow Point Yes 2.57 737 lbs 7 c7 Dead Point Iro 11.43 1310 lbs 6 c7 Live Point Yes 11. 43 2458 lbs 9 c7 Snow Point Yes 11.43 643 lbs 10 j144 Dead Full UDL 11 629.0 plf ll jl44 Live Full UDL Yes 275.0 Rif Load12 Dead FuII UDL No 250.0 plf Self-wei ht Dead Full UDL 170 42.3 1plf Maximum Reactions (lbs) and Bearing Lengths (in) : 14'-3.74" Unfactored: Dead 3348 10010 3403 Live 2863 6017 2947 Snow 383 841 519 Fanter.d: Total 6211, 16027 6351 Bearing: Length 0.86 1.99 0.88 14in re 'd 0.86 1. 99" 0.88 "Minimum bearing length governed by the required width of the supporting member. Maximum reaction on at least one support is from a different load combination than the critical one for bearing design, shown here, due to Kd factor. See Analysis results for reaction from critical load combination. PC6 Timber -soft, D.Fir-L, No.2, 1WIB (11-1/2"x15-1/2") Supports: All - Timber -soft Column, D.Fir-L No.2 Total length: 14'-3.74"; Clear span: 7% T: volume = 17.7 cu.ft.; Beam and stringer Lateral support: top= full, bottom= at all supports; Analysis vs. Allowable Stress and Deflection using Nos 2015: Criterion Anal s s Value Desi n Value Unit Anal sis/Desi I Shear fv =r 54 Fv' 170 psi fv Fv' = 0.32 Bending(+) fb = 307 SO' = 847 psi fb/Eb' = 0.36 Bending(-) fb = 348 FBI = 847 psi fb/Fb' = 0.41 Dead Def1'n 0.01 = <L/999 Live Defl'n 0.01 = <L/999 0.24 = L/360 0.04 Total Def1'n 0.02 = <L/999 0.36 = L/240 i 0.05 Additional Data: FACTORS: F/E(psi)CD Cbl Ct CL CF Cfu Cr Cfrt Ci Cc LC# Fv' 170 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 875 1.00 1.00 1.00 1.000 0.969 1.00 1.00 1.00 1.00 - 5 Fb'- 875 1.00 1.00 1.00 1. 000 0.969 1.00 1.00 1.00 1.00 - 2 F-P' 625 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 - 5 CRITICAL LOAD COMBINATIONS: shear : LC 42 = D+L, V max = 6017, V design = 6363 lbs Bending(+I: LC #5 = D+L (pattern: L ), At = 11799 lbs-ft Sending(-1: LC #2 = D+L, I4 = 13359 lbs-ft Deflection: LC #5 = (live) LC #5 = (total) D=dead L=live S=snow W=wind I=impact Lr=roof live L-concentrated E=earthquake A11 LC, are listed in the Analysis output Load Patterns: s=5/2, X=L+S or L+Lr, - o pattern load in this span Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 4639e06 lb-in2 "Live" deflection = Deflection from all non -dead loads (live, orind, s new I Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. Design Notes: 1. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 213 of 2 span beams and to the full length of cantilevers and other spans. 4. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4A. COMPANY Design Build Services, Inc. PROJECT 510 8ih Ave N - Lot 2 28119 130th Monroe,WA98272Edmonds, Bth Ave N WA 98020 WoodWorks' 59SE510 (360) 793-9659 Thuesen Custom Homes Oct.15,201909:48 pc7r.mvbW Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads: Load Type Distribution Pat- tern Location I'll Start End Magnitude Start End Unit 1 w61 Dead Partial UDL 0.10 9.10 88.7 88.7 pit 2 w61 Live Partial UDL 0.10 9.10 213.3 213.3 plf 3 u,61 Snow Partial UDL 0.10 9.10 33.3 33.3 plf 4 c31 Dead Point 0.10 2724 lbs 5 c31 Snow point 0.10 4437 ibs 6 c80 Dead Point I.11 2510 lbs 7 c80 Snow Point 9.10 2555 lb s B C81 Dead Point 5.10 183 lbs 9 c81 Live Point 5.10 160 in 10 c81 Snow Point 5,10 67 lbs Loadll Dead Pa dial UDL -9'00 0.00 250.0 250.0 p11 Self-wei ht Dead Full UDL 42.3 if Maximum Reactions (lbs) and Bearing Lengths (in) : 10'-1.96, Unfactored: Dead 3723 2918 Live 1133 947 Snow 4897 2463 Factored: Total 8620 5476 Bearing: Length 1.20 0.76 Min re 'd 1.20 0.76 reaction an at least one support is from a different load combination than the critical one for bearing design, shown here, due to Kd factor. See Analysis results for reaction from cmical load combination. pc7 Timber -soft, D.Fir-L, No.2, 12x16 (11-1/2"x15-1/2") Supports: All - Timber -soft Column, D.Fir-L No-2 Total length: 10'-1.96"; Clear span: 10.; volume = 12.6 cu.ft.; Beam and stringer Lateral support: top= full, bottom= at supports; Analysis vs. Allowable Stress and Deflection using Nos 2015: Criterion Anal sis Value -� Desi Value Unit Anal sis/Desi Shear fv* = 31 Fv' 195 spsi fv* Fv' = On19 Bending(+) fb = 168 Fb' = 847 fb/Fb' = 0.20 Dead Defl'n 0.01 = <L/999 Live Defl'n 0.02 = <L/999 0.34 = L/360 0.04 Total Dafl'n 0.03 = <L/999 0.50 = L/240 in 0.06 The effect of point loads within a distance d of the support has been included as per LIDS 3.4.3.1 Additional Data: FACTORS: F/E(psi)CD Cft Ct CL CF Cfu Cc Cfrt Ci Cn LC# Fv' 170 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 3 Fb'+ 875 1.00 1.00 1.00 1.000 0.969 1.00 1.00 1.00 1.00 - 2 Fop' 125 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 - 3 CRITICAL LOAD COMBINATIONS: Shear : LC #3 = D+.75(L+S), V max = 5476, V design* = 4426 lb. Bending(+): LC 42 = D+L, M = 6461 lbs-ft Deflection: LC #3 = D+.75(L+S) (live) LC 43 = D+.75(L+S) (total) D=dead L=live S=snow i4=wind I=impact Lr=roof live L-concentrated E=earthquake All LC' a e listed in the Analysis output Load combinations: AS CE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 4639e06 lb-in2 "Live" deflection = Deflection from all n n-dead loads (live, oind, s ow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.n Design Notes: 1. WoodWorks analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NOS Design Supplement. 2. Please verity that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NOS Clause 4.4.1. COMPANY Design Build Services, Inc. 120thSt SE WoodWorkso Monroe, WA 98272 (360) (360) 793-965959 SOFrrVARFFOR WOOD DFSrON Oct. 15, 201909:48 Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads: Load Type Distribution Pat- tern Location tft] Start End Magnitude Start End Unit 1 w54 Dead Partial UDL 6.04 11.04 15.3 15.3 plf 2 w54 Snow Partial UDL 6.04 11.04 25.0 25.0 plf 3 c78 Dead Point 11.04 32 lbs 4 c78 Snow Point 11.04 50 lbs Load5 Dead Fu 11 UDL 250.0 plf Self -weight Dead Full UDL 42.3 plf Maximum Reactions (lbs) and Bearing Lengths (in) : PROJECT 5108thAve N-Lot 2 510 8th Ave N Edmonds, WA 98020 Thuesen Custom Homes pc7ar.wwb Unfactored: Dead 1637 1710 Snow 29 146 Factored: Total 1665 1857 Bearing: Length 0.50` 0.50* Min req'd 0.50* 0.50* 'Minimum bearing length setting used: 1/2" for end supports Maximum reaction on at least one support is from a different load combination than the critical one for bearing design, shown here, due to Kd factor. See Analysis results for reaction from critical load combination. pc7a Timber -soft, D.Fir-L, No.2, 12x16 (11-1/2"x15-1/2") Supports: All - Timber -soft Column, D.Fir-L No.2 Total length: IV-1.0'; Clear span: IV; volume = 13.7 cu.ft.; Beam and stringer Lateral support: top= full, bottom= at supports; Analysis vs. Allowable Stress and Deflection using NDS 2015: Criterion Analysis Value Design Value Unit Analysis/Design Shear fV = 11 Fv' 153 psi fv/Fv' = 0.07 Bending(+) fb = 119 Fb' = 763 psi fb/Fb' = 0.16 Dead Defl'n 0.02 = <L/999 Live Defl'n negligible Total Def1'n 0.02 = <L/999 1 0.55 = L/240 in 0.04 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 170 0.90 1.00 1.00 - - - - 1.00 1.00 1.00 1 Fb'+ 875 0.90 1.00 1.00 1.000 0.969 1.00 1.00 1.00 1.00 - 1 Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 - 2 CRITICAL LOAD COMBINATIONS: Shear : LC kl = D only, V max - 1673, V design = 1271 lbs Bending(+): LC #1 = D only, M = 4551 lbs-ft Deflection: LC ff2 = D+S (live) LC 142 = D+S (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 4639e06 lb-in2 "Live" deflection = Deflection from all non -dead loads (live, wind, snow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. Design Notes: 1. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. COMPANY Design Build Services, Inc. PROJECT 510 8th Ave N - Lot 2 R U BE Monroe, WA 98272 510 e ve N Edmonds, WA 98020 o d Wo r k s (360) 793-9659 (360) 7 3-96 9 Thuesen Custom Homes e Custom Oct. 15, 2019 09:39 pc8.twib S0Fr1VARE FOR WOOD DESIGN Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads: Load Type Distribution Pat- tern Location [ft) Start End Magnitude Start End Unit 1 w65 Dead Partial UDL Ile 0.06 8.06 100.8 100.8 plf 2 .65 Live Partial UDL Yes 0.06 8.06 190.9 190.9 pif 3 w65 Snow Partial UDL Yes 0.06 8.06 -1%4 -18.4 plf 4 c118 Dead Point Ito 4.56 -43 lbs 5 cll8 snow Point Yes 4.56 -99 lb. 6 j130 Dead Partial UDL Ile 2.06 8.06 50.8 50.8 pif 7 jl30 Live Partial UDL Yes 2.06 B.06 180.0 180.0 plf 8 j142 Dead Partial UDL Ito 8.06 20.06 50.8 50.8 pif 9 j142 Live Partial UDL Yes 8.06 20.06 180.0 180.0 pif 10 j143 Dead Partial UDL Ile 15.72 19.72 629.0 629.0 plf 11 jl43 Live Partial UDL Yes 15.72 19.72 275.0 275.0 plf 12 j144 Dead Partial UDL Ito 2.06 16.06 629.0 629.0 plf 13_j144 Live Partial UDL Yes 2.06 16.06 275.0 275.0 plf 14 j145 Dead Partial UDL iro 0.06 2.06 629.0 629.0 plf 15j 145 Live Partial UDL Yes 0.16 2.06 275.0 275.0 plf Loadl6 Dead Full UDL 11, 250.0 plf Self-wei ht Dead Fu11 UDL Ito 42.3 if Maximum Reactions (lbs) and Bearing Lengths (in) : 20'-4.11" Unfactored• Dead 3450 8576 6031 2144 Live 1932 5023 3418 1144 Snow -95 -189 45 -8 Factored: Total 5382 13600 9450 3287 Bearing: Length 0.75 1.69 1.17 0.50* .inre 'd 0.75 1. 69'* 1.17*� 0.50` 'Minimum bearing length setting used: 1/2° for end supports "Minimum bearing length governed by the required width of the supporting member. pc8 Timber -soft, D.Fir-L, No.2, 12x16 (11-1/2"x15-1/2") Supports: All - Timber -soft Column, D.Fir-L No.2 Total length: 20'-4.11"; Clear span: 8', 6', U; volume = 25.2 cu.fl.; Beam and stringer Lateral support: top= full, bottom= at all supports; Analysis vs. Allowable Stress and Deflection using Nos 2015 : Criterion Anal sis Value Desi n Value Unit Anal sis/Desi Shear fv = 49 Fv' = 170 psi fv Fv' = On29 Bending(+) fb = 250 Fb' = 847 psi fb/Fb' = 0.29 Bending(-) lb = 212 Fb' = 847 psi fb/Fb' = 0.31 Dead Defl'n 0.01 = <L/999 Live Defl'n 0.01 = <L/999 0.27 = L/360 in 0.03 Total Defl'n 0.02 = <L/999 0.41 = L/240 0.05 Additional Data: FACTORS: F/E(psi)CD CPS Ct CL CF Cfu Cr Cfrt Ci Cr, LCH Fv' 170 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 7 Fb'+ 875 1.00 1.00 1.00 1.000 0. 969 1.00 1.00 1.00 1.00 - 9 Fb'- 875 1.00 1.00 1.00 1.000 0.969 1.00 1.00 1.00 1.00 - 7 FOR' 625 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 - 9 CRITICAL LOAD COMBINATIONS: Shear LC p7 = D+L (pattern: LL I, V max = 8102, V design = 5817 lbs Bending(+): LC 49 = D+L (pattern: L LI' M = 9581 lbs-ft Bending(-1: LC q7 = D+L (pattern: LL_), M = 10063 lbs-ft Deflection: LC 49 = (live) LC N9 = (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC, Ile listed in the Analysis output Load Patterns: s=S12, X=L+S or L+Lr, o pattern load in this span Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 4639e06 lb-in2 "Live" deflection = Deflection from all non -dead loads (live, uind, s ow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.n Design Notes: 1. WoodWorks analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NOS Design Supplement. 2. Please vertfy that the default deflection limits are appropriate for your application. 3. Continuous or Cantilevered Beams: NOS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2/3 of 2 span beams and to the full length of cantilevers and other spans. 4. Sawn lumber bending members shall be laterally supported according to the provisions of NOS Clause 4.4.1. 1/7 ANCHOR BOLTS WALL PILE SUPPORTED SLAB NOT TO SCALE �r;s, 1018" O.G. 6 MIL PLASTIC UNDER SLAB Concrete Beam Design Report Concrete Beam Design Job: 30227 Designed By: RDH PE Beam ID: SLAB Checked By: Date: 10/15/2019 4:19:29 PM Program: Concrete Beam Design 4.0 Grade Beam 2/7 Page 1 Code ACI (2011) Design Method Ultimate Strength Member Type One -Way Slab Cross Section Shape Rectangular Snan Data: Main Span Length 11.000 Ft Left End Support Pinned Right End Support Pinned Left Support Width 4.000 In Right Support Width 4.000 In Left Haunch Start Location Not Present Right Haunch Start Location Not Present Cross Section Data: Total Depth at Mid -Span 8.000 In Top Width at Mid -Span 12.000 In Material Datn: Pe 3.000 K/ln2 Flexural Reinforcing fy 60.000 K/In2 Concrete Density 144.000 Lb/Ft' Shear Reinforcing fvy 60.000 K/In2 Concrete Tensile Strength 0.420 K/In2 Stress Block, Beta 0.850 Design C'riteriw Bottom Cover to Stirrup 1.500 In Top Cover to Stirrup 1.500 In Total Load Deflection Limit L/240.00 Live Load Deflection Limit L/360.00 Allow Cuts in Tension Zone N Check Crack Control Provisions Y ECHO OF LOAD INPUT DEAD LOAD LIVE LOAD WIND LOAD EARTHQUAKE LOAD ROOF LOAD Check Deflection: Yes Main Span # 1 Concentrated Load: 0.000 K -1.000 K Distance: 0.000 Ft 5.500 Ft # 1 Uniform Load: -0.150 K /Ft 0.000 K /Ft Distance to Begin: 0.000 Ft 0.000 Ft Distance to End: 11.000 Ft 0.000 Ft CRITICAL SHEARS & MOMENTS Load Combination Dead Load: 1.400 x Dead Load Load Combination # 1: 1.200 x Dead Load + 1.600 x L + 0.500 x R Load Combination # 2: 1.200 x Dead Load + 1.000 x L + 1.600 x R Load Combination # 3: 1.200 x Dead Load + 0.800 x W + 1.600 x R Load Combination # 4: 1.200 x Dead Load + 1.000 x L + 1.600 x W + 0.500 x R DEAD LOAD LOAD COMB 1 LOAD COMB 2 LOAD COMB 3 LOAD COMB 4 Shear Left End: 1.155 K 1.790 K 1.490 K 0.990 K 1.490 K Moment Left End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Shear Right End: -1.155 K -1.790 K -1.490 K -0.990 K -1.490 K Moment Right End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Maximum Moment 3.176 K -Ft 7.123 K -Ft 5.473 K -Ft 2.723 K -Ft 5.473 K -Ft Located at: 5.500 Ft 5.500 Ft 5.500 Ft 5.500 Ft 5.500 Ft Max Deflection -0.031 In -0.084 In -0.084 In -0.031 In -0.084 In Located at: 5.500 Ft 5.500 Ft 5.500 Ft 5.500 Ft 5.500 Ft Dead Part: -0.031 In -0.031 In -0.031 In -0.031 In Inflection Points: 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft D sCustom Homesl4 8th Ave N, Edmonds- Lot 10/15/2019 4:19:29 PM Concrete Beam Design Report 3/7 Page 2 11.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft Reaction Left End: 1.155 K 1.790 K 1.490 K 0.990 K 1.490 K Reaction Right End: 1.155 K 1.790 K 1.490 K 0.990 K 1.490 K Load Combination # 5: 1.200 x Dead Load + 1.000 x L + 1.400 x E + 0.200 x R Load Combination # 6: 0.900 x Dead Load + 1.600 x W Load Combination # 7: 0.900 x Dead Load + 1.400 x E Load Combination # 8: 1.200 x Dead Load - 0.800 x W + 1.600 x R Load Combination # 9: 1.200 x Dead Load + 1.000 x L - 1.600 x W + 0.500 x R LOAD COMB 5 LOAD COMB 6 LOAD COMB 7 LOAD COMB 8 LOAD COMB 9 Shear Left End: 1.490 K 0.743 K 0.743 K 0.990 K 1.490 K Moment Left End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Shear Right End: -1.490 K -0.743 K -0.743 K -0.990 K -1.490 K Moment Right End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Maximum Moment 5.473 K -Ft 2.042 K -Ft 2.042 K -Ft 2.723 K -Ft 5.473 K -Ft Located at: 5.500 Ft 5.500 Ft 5.500 Ft 5.500 Ft 5.500 Ft Max Deflection -0.084 In -0.031 In -0.031 In -0.031 In -0.084 In Located at: 5.500 Ft 5.500 Ft 5.500 Ft 5.500 Ft 5.500 Ft Dead Part: -0.031 In -0.031 In -0.031 In -0.031 In -0.031 In Inflection Points: 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft Reaction Left End: 1.490 K 0.743 K 0.743 K 0.990 K 1.490 K Reaction Right End: 1.490 K 0.743 K 0.743 K 0.990 K 1.490 K Load Combination # 10: 1.200 x Dead Load + 1.000 x L -1.400 x E + 0.200 x R Load Combination # 11: 0.900 x Dead Load -1.600 x W Load Combination # 12: 0.900 x Dead Load - 1.400 x E LOAD COMB 10 LOAD COMB 11 LOAD COMB 12 LOAD COMB 13 LOAD COMB 14 Shear Left End: 1.490 K 0.743 K 0.743 K Moment Left End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Shear Right End: -1.490 K -0.743 K -0.743 K Moment Right End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Maximum Moment 5.473 K -Ft 2.042 K -Ft 2.042 K -Ft Located at: 5.500 Ft 5.500 Ft 5.500 Ft Max Deflection -0.084 In -0.031 In -0.031 In Located at: 5.500 Ft 5.500 Ft 5.500 Ft Dead Part: -0.031 In -0.031 In -0.031 In Inflection Points: 0.000 Ft 0.000 Ft 0.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft Reaction Left End: 1.490 K 0.743 K 0.743 K Reaction Right End: 1.490 K 0.743 K 0.743 K SECTION DESIGN INFORMATION SECTION FLEXURAL DESIGN Mid -Span Region: Cross -Section Information: Total Depth : 8.000 In Distance to Centroid As : 6.25 In Top Width: 12.000 In Distance to Centroid A's : 1.75 In For Design Moment, Mu: 7.123 K -Ft Required As: 0.283 In2 (p : 0.004) Required A's : 0.000 In (p : 0.000) Provided As: 0.400 InZ (p : 0.005) Provided A's: 0.000 I112 (p : 0.000) Reduction Factor, Phi : 0.90 Moment Capacity, *Mn : 10.544 K -Ft 1 Gross Area : 96.000 InZ Gross Moment of Inertia: 512.000 I112 Neutral Axis Location : 4.00 In N (Es/Ec) : 9.28 Modulus, Ec : 3,123.33 K /InZ L:Project FilesCustom Homes14 8th Ave N, Edmonds- Lot 10/15/2019 4:19:29 PM 2Slab.rtf Concrete Beam Design Report 4/7 Page 3 Cracked Moment of Inertia : 96.533 InZ Neutral Axis Location : 6.32 hr Cracking Moment: 4.382 K -Ft * Indicates That Nominal Resistance Includes Appropriate Phi Factor Ot BOTTOM BARS o 0 Mid -Scan Region: I Design Moment, Mu 1 7.12 K-Ft I As Required 1 0.283 In` I As Provided I 0. n` I d 1 6.250 In I Bar Size 44 Number of Layers 1 Layer Spacing 0.00 In Number of Bars 2 Bars in Lower Layer 2 Ld 13.15 In At Left Support: Percent of Bars Continuing into Support 100 Suggested Bar Cutoff (from Centerline of Suppor-t-)----J 0.00 In At Right Support: Percent of Bars Continuing into Support 100 Suggested Bar Cutoff (from Centerline of Support) T 0.00 In MAXIMUM DEFLECTIONS Span Load Comb Short Total Long Total Max Allow Short Live Load Max Allow Ieffective In In In In In In` MAIN Dead -0.031 0.550 OK 512.00 1 -0.084 -0.141 0.550 OK -0.053 0.367 OK 373.04 2 -0.084 -0.141 0.550 OK -0.053 0.367 OK 373.04 3 -0.031 -0.062 0.550 OK 0.000 0.367 OK 512.00 4 -0.084 -0.141 0.550 OK -0.053 0.367 OK 373.04 5 -0.084 -0.141 0.550 OK -0.053 0.367 OK 373.04 6 -0.031 -0.062 0.550 OK 0.000 0.367 OK 512.00 7 -0.031 -0.062 0.550 OK 0.000 0.367 OK 512.00 8 -0.031 -0.062 0.550 OK 0.000 0.367 OK 512.00 9 -0.084 -0.141 0.550 OK -0.053 0.367 OK 373.04 10 -0.084 -0.141 0.550 OK -0.053 0.367 OK 373.04 11 -0.031 -0.062 0.550 OK 0.000 0.367 OK 512.00 12 -0.031 -0.062 0.550 OK 0.000 0.367 OK 512.00 SHEAR DESIGN - MAIN SPAN --------------------- Left Side --------------------- --------------------- Right Side --------------------- Number @ Spacing Al Number @ Spacing Al InZ InZ Spacing starts from face of support .... None Required None Required L:Project FilesCustom Homes14 8th Ave N, Edmonds- Lot 10/15/2019 4:19:29 PM 2Slab.rtf Concrete Beam Design Report Concrete Beam Design Job: 30227 Designed By: RDH PE Beam ID: SLAB Checked By: Date: 10/15/2019 4:55:33 PM Program: Concrete Beam Design 4.0 5/7 Page 1 Description: Slab at Garage Code ACI (2011) Design Method Ultimate Strength Member Tvne One-Wav Slab Cross Section Shane Rectangular Snnn Data Main Span Length 11.000 Ft Left End Support Pinned Right End Support Pinned Left Support Width 4.000 In Right Support Width 4.000 In Left Haunch Start Location Not Present Right Haunch Start Location Not Present Cross Section Data: Total Depth at Mid -Span 8.000 In Top Width at Mid -Span 12.000 In Material Data: fc 3.000 K/In' Flexural Reinforcing fy 60.000 K/In' Concrete Density 144.000 Lb/Ft' Shear Reinforcing fvy 60.000 K/In2 Concrete Tensile Strength 0.420 K/In' Stress Block, Beta 0.850 Desiun Criteria: Bottom Cover to Stirrup 1.500 In Top Cover to Stirrup 1.500 In Total Load Deflection Limit L/240.00 Live Load Deflection Limit L/360.00 Allow Cuts in Tension Zone N Check Crack Control Provisions Y ECHO OF LOAD INPUT DEAD LOAD LIVE LOAD WIND LOAD EARTHQUAKE LOAD ROOF LOAD Check Deflection: Yes Main Span # 1 Uniform Load: 0.150 K /Ft -0.050 K /Ft Distance to Begin: 0.000 Ft 0.000 Ft Distance to End: 11.000 Ft 11.000 Ft CRITICAL SHEARS & MOMENTS Load Combination Dead Load: 1.400 x Dead Load Load Combination # 1: 1.200 x Dead Load + 1.600 x L + 0.500 x R Load Combination # 2: 1.200 x Dead Load + 1.000 x L + 1.600 x R Load Combination # 3: 1.200 x Dead Load + 0.800 x W + 1.600 x R Load Combination # 4: 1.200 x Dead Load + 1.000 x L + 1.600 x W + 0.500 x R DEAD LOAD LOAD COMB 1 LOAD COMB 2 LOAD COMB 3 LOAD COMB 4 Shear Left End: 1.155 K 1.430 K 1.265 K 0.990 K 1.265 K Moment Left End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Shear Right End: -1.155 K -1.430 K -1.265 K -0.990 K -1.265 K Moment Right End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Maximum Moment 3.176 K -Ft 3.933 K -Ft 3.479 K -Ft 2.723 K -Ft 3.479 K -Ft Located at: 5.500 Ft 5.500 Ft 5.500 Ft 5.500 Ft 5.500 Ft Max Deflection -0.031 In -0.041 In -0.041 In -0.031 In -0.041 In Located at: 5.500 Ft 5.500 Ft 5.500 Ft 5.500 Ft 5.500 Ft Dead Part: -0.031 In -0.031 In -0.031 In -0.031 In Inflection Points: 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft Reaction Left End: 1.155 K 1.430 K 1.265 K 0.990 K 1.265 K L: Project FilesCustom mes14 8th Ave N, Edmonds- Lot 2Slab-50 psf.rtf 10/15/2019 4:55:33 PM Concrete Beam Design Report 6/7 Page 2 Reaction Right End: 1.155 K 1.430 K 1.265 K 0.990 K 1.265 K Load Combination # 5: 1.200 x Dead Load + 1.000 x L + 1.400 x E + 0.200 x R Load Combination # 6: 0.900 x Dead Load + 1.600 x W Load Combination # 7: 0.900 x Dead Load + 1.400 x E Load Combination # 8: 1.200 x Dead Load - 0.800 x W + 1.600 x R Load Combination # 9: 1.200 x Dead Load + 1.000 x L - 1.600 x W + 0.500 x R LOAD COMB 5 LOAD COMB 6 LOAD COMB 7 LOAD COMB 8 LOAD COMB 9 Shear Left End: 1.265 K 0.743 K 0.743 K 0.990 K 1.265 K Moment Left End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Shear Right End: -1.265 K -0.743 K -0.743 K -0.990 K -1.265 K Moment Right End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Maximum Moment 3.479 K -Ft 2.042 K -Ft 2.042 K -Ft 2.723 K -Ft 3.479 K -Ft Located at: 5.500 Ft 5.500 Ft 5.500 Ft 5.500 Ft 5.500 Ft Max Deflection -0.041 In -0.031 In -0.031 In -0.031 In -0.041 In Located at: 5.500 Ft 5.500 Ft 5.500 Ft 5.500 Ft 5.500 Ft Dead Part: -0.031 In -0.031 In -0.031 In -0.031 In -0.031 In Inflection Points: 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft 11.000 Ft 11.000 Ft 11,000 Ft 11.000 Ft 11.000 Ft Reaction Left End: 1.265 K 0.743 K 0.743 K 0.990 K 1.265 K Reaction Right End: 1.265 K 0.743 K 0.743 K 0.990 K 1.265 K Load Combination # 10: 1.200 x Dead Load + 1.000 x L - 1.400 x E + 0.200 x R Load Combination # 11: 0.900 x Dead Load -1.600 x W Load Combination # 12: 0.900 x Dead Load -1.400 x E LOAD COMB 10 LOAD COMB 11 LOAD COMB 12 LOAD COMB 13 LOAD COMB 14 Shear Left End: 1.265 K 0.743 K 0.743 K Moment Left End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Shear Right End: -1.265 K -0.743 K -0.743 K Moment Right End: 0.000 K -Ft 0.000 K -Ft 0.000 K -Ft Maximum Moment 3.479 K -Ft 2.042 K -Ft 2.042 K -Ft Located at: 5.500 Ft 5.500 Ft 5.500 Ft Max Deflection -0.041 In -0.031 In -0.031 In Located at: 5.500 Ft 5.500 Ft 5.500 Ft Dead Part: -0.031 In -0.031 In -0.031 In Inflection Points: 0.000 Ft 0.000 Ft 0.000 Ft 11.000 Ft 11.000 Ft 11.000 Ft Reaction Left End: 1.265 K 0.743 K 0.743 K Reaction Right End: 1.265 K 0.743 K 0.743 K SECTION DESIGN INFORMATION SECTION FLEXURAL DESIGN Mid -Span Region: Cross -Section Information: Total Depth : 8.000 In Distance to Centroid As : 6.25 In Top Width: 12.000 In Distance to Centroid A's : 1.75 In For Design Moment, Mu : 3.933 K -Ft Required As: 0.173 In (p : 0.002) Required A's : 0.000 InZ (p : 0.000) Provided As : 0.200 InZ (p : 0.003) Provided A's : 0.000 InZ (p : 0.000) Reduction Factor, Phi : 0.90 Moment Capacity, *Mn: 5.449 K -Ft Gross Area: 96.000 InZ Gross Moment of Inertia: 512.000 In Neutral Axis Location : 4.00 In N (Es/Ec) : 9.28 Modulus, Ec : 3,123.33 K /InZ Cracked Moment of Inertia: 54.237 In Neutral Axis Location : 6.76 In Cracking Moment: 4.382 K -Ft L: Project FilesCustom Homes14 8th Ave N, Edmonds- Lot 10/15/2019 4:55:33 PM 2Slab-50 psf.rtf Concrete Beam Design Report * Indicates That Nominal Resistance Includes Appropriate Phi Factor 7/7 Page 3 BOTTOM BARS Mid -Span Region: Design Moment, Mu 393 K-Ft As Required 0.173 In' As Provided 0.200 1112 d 6.250 In Bar Size 44 Number of Layers 1 Layer Spacing 0.00 In Number of Bars 1 Bars in Lower Layer 1 Ld 13.15 In At Left Support: Percent of Bars Continuing into Support 100 Suggested Bar Cutoff (from Centerline of Support) 0.00 In At Right Support: Percent of Bars Continuing into Support 100 Suggested Bar Cutoff (from Centerline of Support) 0.00 In MAXIMUM DEFLECTIONS Span Load Comb Short Total Long Total Max Allow Short Live Load Max Allow Ieffeetive In In In In In Ina MAIN Dead -0.031 0.550 OK 512.00 1 -0.041 -0.077 0.550 OK -0.010 0.367 OK 512.00 2 -0.041 -0.077 0.550 OK -0.010 0.367 OK 512.00 3 -0.031 -0.062 0.550 OK 0.000 0.367 OK 512.00 4 -0.041 -0.077 0.550 OK -0.010 0.367 OK 512.00 5 -0.041 -0.077 0.550 OK -0.010 0.367 OK 512.00 6 -0.031 -0.062 0.550 OK 0.000 0.367 OK 512.00 7 -0.031 -0.062 0.550 OK 0.000 0.367 OK 512.00 8 -0.031 -0.062 0.550 OK 0.000 0.367 OK 512.00 9 -0.041 -0.077 0.550 OK -0.010 0.367 OK 512.00 10 -0.041 -0.077 0.550 OK -0.010 0.367 OK 512.00 11 -0.031 -0.062 0.550 OK 0.000 0.367 OK 512.00 12 -0.031 -0.062 0.550 OK 0.000 0.367 OK 512.00 SHEAR DESIGN - MAIN SPAN --------------------- Left Side --------------------- --------------------- Right Side --------------------- Number @ Spacing Al Number @ Spacing Al InZ Lie Spacing starts from face of support .... None Required None Required L:Project FilesCustom Homes14 8th Ave N, Edmonds- Lot 10/15/2019 4:55:33 PM 2Slab-50 psf.rtf FI� WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN Thuesen-514 8th Ave N det. garage 2019.wwa WoodWorks(D Sizer 11.1.1 Oct. 16, 2019 11:26:42 Concept Mode: Beam View Roof: 18' 19 25 4 13 14 22 b16 J' 25 7 c 0 16 b15 /20 A 11 Li �241 23 1 27 912 1 b11 1 g 1; 24 b13 _ 3 17 18 1 A B L G M S H N F I K T 0 J P 0 C R D E 0'-6" 2' 4' 8' 10' 12' 14' 16' 17' 18' 19' 20' 21' 23' 24' 25' 26' 2T-6" 3-6' 12'-6" 28' 27'-6" 26 2 21' 20' 18, 17'-6" 17' 16' 15'-6" 14' 12'-F 12' 10'-6" 9' 8' 6' 5' _6" 4' 2'_6" 9' 00 F-1 F— WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN Thuesen-514 8th Ave N det. garage 2019.wwa WoodWorksO Sizer 11.1.1 Oct. 16, 2019 11:26:31 Concept Mode: Beam View Floor 2: 10, 5 --b18. ✓ t/�% C..... t,l..�i �' C_ d L� \�.. 30' 19 25 4 k 14 22 26. 15 7 21 ` C b1 �i .Y ( t l� ,fl b7 1120 $ 6 10 a 23 27 / �L f L S L— a 24 g b2 b� 0 1 17 1 b4 G `C 18 1 A B L G M "�1"H'N F I K T 0 J P 0 C R D E 0'-6" 2' 4' 8' 12' 14' 16' 17' 18' 19' 20' 21' 23' 24' 25' 26' 27-6' 3,-6„ 12'-G„ 28' i! � 27'_6" 1 o ,; L L 26 23' 21' IZA 20' 1' 7 17' 16' 14' t 12'-6„ 10'-6„ 9' a' 7' 6' 4'-6„ 2'-6" 2' 0'-6„ 0' N c0 7 � WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN Thuesen-514 8th Ave N det. garage 2019.wwa WoodWorks(D Sizer 11.1.1 i Oct. 16, 2019 11:26:10 Concept Mode: Reactions at Base of Structure View Floor 1: 1 5.. '. - 19 w38' 255 D 63 D k �' k /\ 25 250E 1 � PU t'�<. �, C_ 196 D c40 c39 w c6 c31 c24 c25 c32 c42 4 254 S 699 S 5258 L 500 L-27 S 376 S 238 S 182 D 470 D 532 S 192 D01 D 2115 D 168 D 13. 240 L na S 14 Y c10 D c28 240 L 22 rJ. �f� .C. : - 106 S 262 S /� G� a? 154 D 172 D 26 C11 15 c8 7 - 240 L 360 L' 9A5 S 21 371 S c!2 D 16 6376 D L 240 L 6 /mow 2180 117S360 4 L ... S : � / D Jan 1 1 20 �aGs C26 D}} Z\ - c13S 1 Rn n 240 L 2623 : 1 \ 1A1 S 172 D ^ c14 D nh c35 S 23 : 1Rn n 670 S 27 478 D cio 9_ 1 -. c17 240 L 1 RA S 1165 S c16 D 8 789 D 24 c1 w5 c2 c5 c18 L 3 4S. 306 S 77 S 306 S 4822 L' 699 S : 152 D 38 D 152 3653 S_ 437 D 17 4341 D c3 w3 c4 2 nu�q 306 S 77 S 306 S 152 D 38 D 152 D 18 1 A B L G M S H N F I K T 0 J P 0 C R D E 0'-6" 2' 4' 10. 12' 14' 16' 17' 18' 19' 20' 21' 23' 24' 25' 26' 27'-6" 12'-6" 23' 27'-G' 26' 23' 21' 20' 18' 1 T-6" 17' 12'-6" 12' 10'-6" 9' 8' 7' 6' 5' 4' 2'_6" 2' 0'-6„ 0, Design Build 5ervice5, Inc. Engineering and GonStruction Management 25119 -120th 5t. 5.E., Monroe, WA 98272 Phone/Fax #(360) 793-9059 Thuesen 514 i8th Ave N -Lot 2 Garage Foundation Analysis Allowable Bearing Pressure 2000 Design DL+ Live Load Column Footing # DL LL SL DL+LL DL+SL .75(LL+SL) (lb) c5 6183 4822 3653 11005 9836 12539 6356 c6 3588 5258 532 8846 4120 7931 5258 c17 1269 1165 1269 2434 2143 1165 Strip Footings DL LL SL DL+LL DL+SL c5 6183 4822 3653 11005 9836 c6 3588 5258 532 8846 4120 c17 1269 1165' 1269 2434 Wall, DL Wall, LL Wall, SL Strip Footing w/Wall c5 160 77 c6 412 80 288' c17 321 240 117 Design Load Area (lb) (sf) 12539 6.3 8846 4.4 2434 1.2 Strip width 12 in Design Design DL+ Live Load Load .75(LL+SL) (lb) (lb) 12539 6356 12539 7931 5258 8846 2143 1165 2434 Footing Size 30 in Square 25 in Square 18 in Round Stem Height (up from ground) 2.0 ft Area Min. Footing Length A 6.3 6.3 ft long 4.4 4.4 ft long 1.2 1.2 ft long DL+ Design DL+LL DL+SL .75(LL+SL) Live Load Wall Load Combined Pressure Strip Width (lb) (plf) (psf) DCR Min. Strip Widtl 160 237 218 77 237 1826.1 0.9 11.0 in. 492 700 688 288 700 2014.5 1.0 12.1 in. 561 438 589 268 589 880.0 0.4 5.3 in. .rN INI 00 Q COMPANY Design Build Services, Inc. SE WoodWorKS Monroe, WA 98272 (360) 793-9659 (360) 93-9 9 SOFiWAREFOR WOOD DESIGN Oct. 16, 201913:51 Design Check Calculation Sheet Wood Works Sizer 11.1,1 Loads Load Type Distribution Pat- tern Location [ft] Start End Magnitude Start End Unit 1_c27 Dead Point 1.04 368 lbs 2 c27 Snow Point 1.04 556 lbs 3 j2 Dead Full UDL 87.0 plf 4 j2 Live Full UDL 240.0 plf Loads Dead Full UDL 80.0 plf elf -weight Dead Full UDL 4.6 plf Maximum Reactions (lbs) and Bearing Lengths (in) US PROJECT 514 8th Ave N - Lot 2 514 8th Ave N Edmonds, WA 98020 Thuesen Custom Homes bl .wwb Unfactored: Dead 509 388 Live 370 370 Snow 369 187 Factored: Total 1064 805 Bearing: Length 0.50* 0.50, Min req'd 0.50- 0.50* 'Minimum bearing length setting used: 1/2" for end supports Maximum reaction on at least one support is from a different load combination than the critical one for bearing design, shown here, due to Kd factor. See Analysis results for reaction from critical load combination. b1 Lumber -soft, D.Fir-L, No.2, 4x6 (3-1/2"x5-1/2") Supports: All - Timber -soft Column, D.Fir-L No.2 Total length: 3'-1.9% Clear span: T; volume = 0.4 cu.ft. Lateral support: top= full, bottom= at supports; Analysis vs. Allowable Stress and Deflection using NDS 2015: Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 69 Fv' = 207 psi fv/Fv' = 0.33 Bending(+) fb = 609 Fb' = 1345 psi fb/Fb' = 0.45 Dead Defl'n 0.01 = <L/999 Live Defl'n 0.01 = <L/999 0.10 = L/360 in 0.09 Total Defl'n 0.02 = <L/999 0.15 = L/240 in 0.12 Additional Data: FACTORS: F/E(psi)CD Ci11 Ct CL CF Cfu Cr Cfrt Ci Cn LC# FV' 180 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 3 Fb'+ 900 1.15 1.00 1.00 1.000 1.300 1.00 1.00 1.00 1.00 - 3 Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 3 CRITICAL LOAD COMBINATIONS: Shear : LC fk3 = D+.75(L+S), V max = 1056, V design = 888 Ibs Bending(+): LC 0 = D+.75(L+S), 1.1 = 895 lbs-ft Deflection: LC 43 = D+.75(L+S) (live) LC 03 = D+.75(L+S) (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 77.6e06 lb-in2 "Live" deflection = Deflection from all non -dead loads (live, wind, snow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. Design Notes: 1. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. COMPANY Design Build Services, Inc. 28119 2 E PROJECT 514 8th Ave N - Lot 2 e N WoodWorks' Monroe A 982 Monroe, WA 98272 Edmonds, WA 98020 s, W Edmonds (360) 793-9659 Thuesen Custom Homes SOF11YARE FOR WOOD DESIGN Oct. 16, 2019 13:52 b2.wwb Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads Load Type Distribution Pat- Location (ft] Magnitude Unit tern Start End Start End 1 j5 Dead Full UDL 38.1 plf 2 j5 Snow Full UDL 76.6 plf Load3 Dead Full UDL 20.0 plf Self -weight Dead Full UDL 9.4 plf Maximum Reactions (Ibs) and Bearing Lengths (in) : 8'-1" Unfactored: Dead 272 272 Snow 309 309 Factored: Total 582 582 Bearing: Length 0.50* 0.50* Min re 'd 0.50* 0.50* *Minimum bearing length setting used: 112" for end supports b2 Lumber -soft, D.Fir-L, No.2, 4x12 (3-1/2"x11-1/4") Supports: All - Timber -soft Column, D.Fir-L No.2 Total length: 8'-1.0'; Clear span: 8'; volume = 2.2 tuft. Lateral support: top= full, bottom= at supports; Analysis vs. Allowable Stress and Deflection using NDS 2015: Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 17 Fv' = 207 psi fv/Fv' = 0.08 Bending(+) fb = 189 Fb' = 1138 psi fb/Fb' = 0.17 Dead Defl'n 0.01 = <L/999 Live Defl'n 0.01 = <L/999 0.27 = L/360 in 0.04 Total Defl'n 0.02 = <L/999 0.40 = L/240 in 0.05 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 180 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 900 1.15 1.00 1.00 1.000 1.100 1.00 1.00 1.00 1.00 - 2 Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 2 Emin' 0.56 million 1.00 1.00 - - - - 1.00 1.00 - 2 CRITICAL LOAD COMBINATIONS: Shear : LC 42 = D+S, V max = 579, V design = 441 Ibs Bending(+): LC If2 = D+S, M = 1164 Ibs-ft Deflection: LC 42 = D+S (live) LC k2 = D+S (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 664e06 lb-in2 "Live" deflection = Deflection from all non -dead loads (live, wind, snow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. Design Notes: 1. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. COMPANY Oeslgn Bu'd Serrces, Inc. PROJECT . , . 51481h Ave N - Lot 2 28119120th St SE h4antce WA 96272 5148th Ave N Edmonds, WA 98020(360)7919659 IG) Thuesen Custom Homes [ WoodWorks' Oct. 16, 2019 t3.55 b3.nwb Design Check Calculation Sheet WaoWorks Ste, 11.1.1 Loads: LO aj Type Dlst rf button Pat- t Lo as Lion [ft7 1., A Naa of Ludo .t I r+ 1--11 trio! UDL 0.0 JtStart153 153d ol1Ef - Pa rCf al UDL 0.00 2.OJ 12, 25,0 o 3 -33 '13 It 521 c3J c3{ _can e36 C�ai Dead 3m'a Deatl Foint E.21 -it ?.00 ^_.OJ '�. ^_.00 -O.nO .00 ]03t 1JII 2JD 24Q 63 92 Ira IGa I11 Ibs Ibs Ibs 5 jl lO j1 11 72 12j2 1 i_j3 J j3 Dead Live Dea] Live D.aU - `a] ±Clot UDL ±tlal VDL ±tlal ULL ±tial UDL ccl=_1 UDL rL=1 UDL 13.00 2.00 13.00 22.OU 1G.00 11.00 30.00 13.00 2.OD 1G.00 2.UG 1G.00 87.Dif 9.0 2JJ.J 8'1 .0 6G.J 2J0.0 J.9 a].[J 0 '!.D 20JD.0 2J0.0 if plf plf plf plf 15 j10 16 j19 Pa±ti=_1 U ea LI1aL UDL O.OJ 1.00 O.OD 1.90 'e.5 5 2i0.0 216.0 pl11 f 1] j11 Leaf Partial U 1.OD 3.00 N9.5 5 6.5 plf d j it Live Pactial U 1.G0 3.00 2d0.0 2J0.0 plf ?j 12 - Pactial U 3.OG 6.50 9n.5 plf 0_]12 Llva E'artial U 3.GJ fi.50 2A0.0 2{0.0 pl£ 'l_J33e ?2_j13 a5 Ll va Partial U Partial U ii-5D Z.SD 50 a.SD 89.5 - 5 5 .- 2{0.0 2{9.0 plf plf jSJ P_a5 earial U a.50 11. 50 aa.5 5 a. p1f -1 j19 LL va Partial U a-50 11.50 240.G 2A J.D p1L _ _jls ''?6 j15 W_ad Ltva Partial u k'a r3a1 U 11.5G 13.50 11 .5G 13.50 a9.5 a8.5 210.G 2{9,G plf plE 2> j16 W_ad ea rcial UDL 13.59 11.00 a9.5 a9.5 p1E e j1b' Liv=_ Partial UpL 13.50 11.9E 2J0-G 210.0 plf f jl"/ 10 117 Cead Llve Partial UDL earial UpL 19.90 11. Ov 19.00 ad.5 69.5 2l0.0 plf oli 31 jt6 ial upG 19:10 a0-0 a-5 s 3_ jlv Ll v vial UDL 19.OG 22.�r1i - 2{O.0 -17c9 plE 111 3 t C_=_d eclat feint - - 1-/"I2 11s lbs Loa�3i C ad Pavial UDI. -,._ 0-0 50. clf I,o a]3n Self-;r=Ia R' D=ad D=ad N11 UDL Full UDL aG _G plE olf Maximum Reactions (Ibs) and Bearing Lengths (in) : onEa_mra c=ad Li•:e Deis ��� 2, s sn.�:, 3aw Jsv tal511i63 :G o"/ a clnT: cth hl 'mum reaction on at least ono support is from a d4ferent load oombinafion than the critical one for 1,awi g dasfp. sham here, due to Kd factor. Sea An ys+s resuRs for reactor from Grit I bad -Ur abort. b3 Glulam-Unbal., West Species, 24F-V4 OF, 13-1/2"xt6-1/2" 17 Wrrt - Llo ea md.-, nGth, suwpffi: A9-Lumbx Post Column, O.F -LNo2 TMaI lateral up orLtCleaspan: 21'S;vuvme= 13.9 cu.fl. Lateral support top= hA, bottom= at supports; Analysis vs. Allowable Stress and Deflection uslnn NDS2oi5: = OM Additional Data: �. F/ElpsvlCD CL EFv'0 .OG 1n0 1�. OJ I.iiO 1L0 11.0,. d5 24H L.UG I.nO 1.D0 1-ODO �- 1.DD L-OG - 1,5 hill ion 1.!+V 1.1c E,iny' 0. 85 mil llon 1.GD 1 0 CRITICAL LOAD COlABINATIONS: Shear LC RZ pal, 955� lba e ndinUlrl: LC e p : 1 - J68 Sts-f[ e z 1 - { Deflem do n: LC !2 - DrL (11va1 L^_ R2 DrL Ito tall G=daad L=live a- - �:+1 n3 L=icaact L±�conf llvr L.=:=. nc eni. roc ad E-=a rch3uaV=_ P11 Lr•s a e 1latctlA the y=_is o t_d co rbinattans: ASCE 7-10 / I.._ 2915 u CALCULATIONS' Da Elec <io n: EL = 3]OnaOu IV-i n2 "Elva" deflaa LLon x L4flectlon fro:.i all n - -_ s Viva, rind, a . v_I r ct al D=_f teetion = 1.00I Deal tvad IY_E1e. ti.cnl tdLi ;ad Lt ad paEle e[La n.n Design Notes: 1. WocwWorks ana!)sIs and dea'g, we ki accordancepiththeICC International BvMag Core (IBC MIS), the National Destgn Specif Eon(NOS 2015). and NOS Des!gn Supp:.ement. 2 Please verify that the def.0 darao n ti Ia are appropriate for )-aW..bon. 3. GO- das'gn va arefor materials conforfn'.ng to ANSI I17-2015 ant manufactured in accordance wdh AN SI At 90.1-2012 4. GLULAAI. bxd = actual breadth x acual depth. 5. Glulam Beams shag be Iate W su000ded accordi a to the prooiam, of NOS Clause 3 3.3. COMPANY Design Build Services, Inc. I PROJECT 514 81h Ave N - Lot 2 WA 96272 206.)76 Edmonds, WA98020 WoodWorks' -9659SE51481hA (360)793-9659 ustMonroe, Thuesen Custom Homes Oct. 16, 2019 13:56 b1mvib Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads: Load Type Distribution Pat- tern Location [ft] Start End Magnitude Start End Unit 1 c19 Dead Point 2.07 98 lbs 2 c19 Snow Point 2.07 153 lb s 3 c20 Dead Point 6.07 601 lbs 4 c20 Snow Point 6.07 878 lb s 5 c21 Dead Point 10.07 623 lbs 6.21 Snow Polot 10.07 846 lbs 7 w20 Dead Partial UDL 0.07 2.07 34.4 34.4 P1f 8 w20 Snow Partial UDL 0.07 2.07 56.3 56.3 plf 9 v21 Dead Partial UDL 10,07 12.07 226.3 226.3 Plf 10 w21 Snow Partial UDL 10.07 12.07 287.5 287.5 pif 11 c41 Dead Point 0.07 171 lbs 12 c41 Snow point 0.07 241 lb, 13 j4 Dead Partial UDL 0.07 2.07 5.4 5.9 pif 14 j4 Snow Partial UDL 0,07 2.07 10.9 10.9 plf 15 j5 Dead Partial UDL 2,07 10.07 5.4 5.4 pif 16 j5 Snow Partial UDL 2,07 10.07 10.9 10.9 plf 17 j6 Dead Partial UDL 10.07 12.07 5.4 5.4 plf 18 j6 Snow Partial UDL 10.07 12.07 10.9 10.9 plf Load19 Dead Full UDL 80.0 plf Self-wei ht Dead Full UDL 10.4 1plf Maximum Reactions (Ibs) and Bearing Lengths (in) : 12'-2.29" 12'-1.14" Unfacto red: Dead 1344 1836 moor 1172 1765 Factored: Total 2511 3Hl Hearing: Length 0.80 1.49 .in re 'd 0.80 1.49" Minimum bearing length governed by the required width of the supporting member. b9 LSL, 1.55E, 1.55E, 3-1/2"x9-1/2", 1-ply Supports: 1 -Timber-soft Column, D.Fir-L No.2; 2- Lumber -soft Beam, D.Fir-L No.2; Total length: 12'-2.29"; Clear span: 12'; volume = 18 ca.ft. Lateral support: top= full, bottom= at supports; Repetitive factor: applied where permitted (refer to online help); Analysis vs. Allowable Stress and Deflection using NDS 2015: Criterion Analysis Value Design Value Unit Anal sis/Desi Shear fv =140 Fv' -� 357 psi fv Fv' = On39 Bending(+I fb = 2012 Fb' = 2674 psi fb/Fb' = 0.75 Dead Defl'n 0.30 = L/487 Live Defl'n 0.27 = L/542 0.40 = L/360 in 0.66 Total Def1'n 0.57 = L/256 1 0.60 = L/240 in 0.93 Additional Data: FACTORS: F/E(psi)CD C[1 Ct CL CV Cfu Cr Cfrt Ci Cn LC# Fv' 310 1.15 - 1.00 - - - - 1,00 - 1.00 2 Fb'+ 2325 1.15 - 1.00 1. 000 1.00 - 1.00 1.00 - - 2 Fcp' 900 - - 1.00 - - - - 1.00 - - - E' 1.6 million - 1.00 - - - - 1.00 - - 2 Emin' 0.80 million - 1.00 - - - - 1.00 - - 2 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D+S, V max = 3596, V design = 3112 Ibs Bending(+): LC #2 = D+S, M = 8828 lb.-ft Deflection: LC #2 = D+S (live) LC 42 = D+S (total) D=dead L=live S=snow N=wind I=impact Lr=roof live L-concentrated E=earthquake All LC's a e listed in the Analysis output Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 388e06 lb-in2 "Live" deflection = Deflection from all n n-dead loads (live, wind, snow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. Design Notes: 1. Woorworks analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification INDS 2015), and NOS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. System factor KH may not apply to field -assembled multi -ply beams. 4. SCL BEAMS (Structural Composite Lumber): the attached SCL selection is for preliminary design only. For final member design contact your local SCL manufacturer. 5. Size factors vary from one manufacturer to another for SCL materials. They can be changed in the database editor. 6. BUILT-UP SCL-BEAMS: contact manufacturer for connection details when loads are not applied equally to all plys. COMPANY Design Build Services, Inc. PROJECT 514 8th Ave N - Lot 2 281 120th SE Monroe, WA 98272 514 8th Ave N Edmonds, WA 98020 WoodWorks' (360) 793-9659 (360) 59 Thuesen Custom Homes Oct. 16, 2019 13:57 b10.wwb SOFFIYAREFOR "'ODD DESIGN Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads: Load Type Distribution Pat- tern Location [ft] Start End Magnitude Start End Unit 1 c22 Dead Point 3.00 190 lbs 2 c22 Snow Point 3.00 296 lb s 3 c23 Dead Point 1.00 190 lbs 4 c23 Snow Point 9.00 296 lbs 5 w23 Dead Partial UDL 0,00 3.00 52.1 52.1 Rif 6 w23 Snow Partial UDL 0.00 3.00 84.4 84.4 plf 7 w24 Dead Partial UDL 9.00 12.00 52.1 52.1 pit 8 w24 Snow Partial UDL 9.00 12.00 84.4 84.4 plf 9 c37 Dead Point 12.00 58 lbs 10 c37 Snow Point 12.00 84 lbs ll j7 Dead Partial UDL 0.00 2.00 11, 5.4 Rif 12_j7 Snow Partial UDL 0,00 2.00 10.9 10.9 plf 13 j8 Dead Partial UDL 2.00 10.00 5.4 5.4 plf 14j8 Snow Partial UDL 2.00 10.00 10.9 10.9 plf 15 j9 Dead Partial UDL 10.00 12.00 5.4 5.4 Rif 129 Snow Partial UDL 10.00 12.00 10.9 10.9 plf Loadl7 Dead Full UDL 80.0 Rif Self -weight Dead Full UDL 5.2 if Maximum Reactions (lbs) and Bearing Lengths (in) : 12' 11W.02" Unfactored: Dead 889 948 Snow 614 699 Factored: Total 1502 1647 Bearing: Length 3.50 3.11 Min re 'd 2.12** 1.91'* Minimum bearing length governed by the required width of the supporting member. b10 LSL, 1.55E, 1.55E, 1-3/4"x9-1/2", 1-ply Supports: All - Lumber -soft Sill plate, Hem -Fir No.2 Total length: 12'; Clear span: 1 V-5"; volume = 1.4 cu.ft. Lateral support: top= full, bottom= at supports; Analysis vs. Allowable Stress and Deflection using Nos 2015: Criterion Anal s s Va1ue -� Desi Value Unit Analysis/Desi She fv = 113 Fv' 357 psi fv F;; = On32 Bending(+) fb = 1638 Fb' = 2674 psi fb/Fb' = 0.61 Dead Def 1'n 0.29 = L/476 Live Defl'n 0.18 = L/755 0.39 = L/360 in 0.48 Total Defl'n 0.48 = L/292 1 0.58 = L/240 in 0.82 Additional Data: FACTORS: F/E(psi)CD CIA Ct CL CV Cfu Cr Cfrt Ci Cn LC4 Fv' 310 1.15 - 1.00 - - - - 1.00 - 1.00 2 Fb'+ 2325 1.15 - 1.00 1.000 1.00 - 1.00 1.00 - - 2 Fop' 900 - - 1.00 - - - - 1.00 - - - E' 1" million - 1.00 - - - - 1.00 - - 2 Emin' 0'80 million - 1.00 - - - - 1.00 - - 2 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D+S, V max = 1455, V design = 1248 lbs Bending(+): LC 12 = D+S, EI = 3592 lbs-ft Deflection: LC #2 = D+S (live) LC p2 = D+S (total) D=dead L=live S=snow W=wind I=impact Lr=roof live L-concentrated E=earthquake All LC'a a e listed in the Analysis output Load combinations: RICE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 194e06 lb-in2 "Live" deflection = Deflection rom all n n-dead loads (live, wind, s ow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.n Design Notes: 1. Wood Works analysts and design are in accordance voth the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3, SCL-BEAMS (Structural Composite Lumber): the attached SCL selection is for preliminary design only. For final member design contact your local SCL manufacturer. 4. Size factors vary from one manufacturer to another for SCL materials. They can be changed in the database editor. 5. BUILT-UP SCL-BEAMS: contact manufacturer for connection details when loads are not applied equally to ail plys. COMPANY Design Build Services, Inc. 28119 EEdmon PROJECT 514 8th Ave N - Lot 2 e NMonroe, 1a) WoodWorks' Monroe2 A 982 WA 98272 Edmonds, WA 98020 s, (360) 793-9659 Thuesen Custom Homes SOF11VAREFOR WOOD DESIGN Oct. 16, 2019 13:59 bl3.wwb Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads Load Type Distribution Pat- tern Location [ft] Start End Magnitude Start End Unit 1 j22 Dead Trapezoidal 0.04 2.04 52.1 66.0 plf 2 j22 Snow Trapezoidal 0.04 2.04 84.4 105.6 plf 3 j23 Dead Partial UDL 2.04 4.04 66.0 66.0 plf 4 j23 Snow Partial UDL 2.04 4.04 105.6 105.6 plf 5 j24 Dead Trapezoidal 4.04 6.04 66.0 52.1 plf 6 j24 Snow Trapezoidal 4.04 6.04 105.6 84.4 plf Self -weight Dead Full UDL 4.6 plf Maximum Reactions (lbs) and Bearing Lengths (in) : 6'-1" Unfactored: Dead 198 198 Snow 296 296 Factored: Total 494 494 Bearing: Length 0.50* 0.50* 1-fin re 'd 0.50* 0.50* 'Minimum bearing length setting used: 1/2" for end supports b13 Lumber -soft, D.Fir-L, No.2, 4x6 (3-1/2"x6-1/2") Supports: All - Timber -soft Column, D.Fir-L No.2 Total length: 6-1.0"; Clear span: 6% volume = 0.8 cu.ft. Lateral support: top= full, bottom= at supports; Analysis vs. Allowable Stress and Deflection using Nos 2015 : Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 33 Fv' = 207 psi fv/Fv' = 0.16 Bending(+) fb = 530 Fb' = 1345 psi fb/Fb' = 0.39 Dead Defl'n 0.03 = <L/999 Live Def1'n 0.04 = <L/999 0.20 = L/360 in 0.20 Total Def1'n 0.07 = <L/999 0.30 = L/240 in 0.22 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LCk Fv' ISO 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 900 1.15 1.00 1.00 1.000 1.300 1.00 1.00 1.00 1.00 - 2 Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 2 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D+S, V max = 494, V design = 427 lbs Bending(+): LC 42 = D+S, M = 780 lbs-ft Deflection: LC 42 = D+S (live) LC 42 = D+S (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: ES = 77.6e06 lb-in2 "Live" deflection = Deflection from all non -dead loads (live, wind, snow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. Design Notes: 1. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. COMPANY Design Build Services, Inc. PROJECT 514 8th Ave N - Lot 2 O 19 2 E e N ®®� Wo r k s M nroe A 982 Monroe, WA 98272 Edmonds, WA 98020 Edmonds, s, (360)793-9659 Thuesen Custom Homes SOFTWARE FOR WOOD DESIGN Oct. 16, 201914:00 b12.wwb Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads Load Type Distribution Pat- tern Location [ftj Start End Magnitude Start End Unit l_j34 Dead Partial UDL 2.05 4.05 226.3 226.3 plf 2 j34 Snow Partial UDL 2.05 4.05 287.5 287.5 plf 3 j54 Dead Trapezoidal 0.05 2.05 74.1 91.9 plf 6 j54 Snow Trapezoidal 0.05 2.05 117.2 141.0 plf 5 b26 Dead Point 2.05 468 lbs 6 b26 Snow Point 2.05 697 lbs Self-wei ht Dead Full UDL 6.0 if Maximum Reactions (lbs) and Bearing Lengths (in) : 4'-1.21" Unfa ctored: Dead 484 627 Snow 686 844 Factored: Total 1170 1471 Bearing: Length 0.53 0.67 Min req'd 0.53 0.67 b12 Lumber -soft, D.Fir-L, No.2, 4x8 (3-1/2"x7-1/4") Supports: All - Timber -soft Column, D.Fir-L No.2 Total length: 4'-1.21"; Clear span: 4% volume = 0.7 cu.ft. Lateral support: top= full, bottom= at supports; Analysis vs. Allowable Stress and Deflection using NDS 2015: Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 69 Fv' = 207 psi fv/Fv' = 0.33 Bending(+) fb = 760 Fb' = 1345 psi fb/Fb' = 0.57 Dead Defl'n 0.01 = <L/999 Live Defl'n 0.02 = <L/999 0.14 = L/360 in 0.12 Total Defl'n 0.03 = <L/999 0.20 = L/240 in 0.14 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LCk Fv' 180 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb1+ 900 1.15 1.00 1.00 1.000 1.300 1.00 1.00 1.00 1.00 - 2 Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 2 Emin' 0.58 million 1.00 1.00 - - - - 1.00 1.00 - 2 CRITICAL LOAD COMBINATIONS: Shear : LC ff2 = D+S, V max = 1471, V design = 1173 lbs Bending(+): LC #2 = D+S, td = 1943 lbs-ft Deflection: LC 02 = D+S (live) LC 02 = D+S (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 178e06 lb-in2 "Live" deflection = Deflection from all non -dead loads (live, wind, snow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. Design Notes: 1. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. COMPANY Design Build Services, Inc. 20th St3-9659 SE WoodWorks' Monroe, WA 98272 (.60) 7 (360) 793-9659 SOFTWARE FOR WOOD DESIGN Oct. 16, 201914:01 Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads Load Type Distribution Pat- tern Location [ft) Start End Magnitude Start End Unit 1 j32 Dead Partial UDL 0.04 1.04 189.7 189.7 plf 2_j32 Snow Partial UDL 0.04 1.04 251.7 251.7 plf 3 j44 Dead Trapezoidal 1.04 3.04 91.9 74.1 plf 4 j44 Snow Trapezoidal 1.04 3.04 141.0 117.2 plf 5 b24 Dead Point 1.04 422 lbs 6 b24 Snow Point 1.04 493 lbs Self -weight Dead Full UDL 4.6 plf Maximum Reactions (lbs) and Bearing Lengths (in) 3'-1.02" PROJECT 514 8th Ave N - Lot 2 514 8th Ave N Edmonds, WA 98020 Thuesen Custom Homes bl4.wwb Unfactored: Dead 502 289 Snow 625 376 Factored: Total 1127 667 Bearing: Length 0.52 0.50` Min req'd 0.52 0.50* 'Minimum bearing length setting used: 1/2" for end supports b14 Lumber -soft, D.Fir-L, No.2, 4x6 (3-1/2"x5-1/2") Supports: All - Timber -soft Column, D.Fir-L No.2 Total length: 3'-1.02'; Clear span: 3'; volume = 0.4 cu.ft. Lateral support: top= full, bottom= at supports; Analysis vs. Allowable Stress and Deflection using Nos 2015 : Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 73 Fv' = 207 psi fv/Fv' = 0.35 Bending(+) fb = 631 Fb' = 1345 psi fb/Fb' = 0.47 Dead Defl'n 0.01 = <L/999 Live Defl'n 0.01 = <L/999 0.10 = L/360 in 0.09 Total Defl'n 0.02 = <L/999 0.15 = L/240 in 0.11 Additional Data: FACTORS: F/E(psi)CD C111 Ct CL CF Cfu Cr Cfrt Ci Cn LCO Fv' 180 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 900 1.15 1.00 1.00 1.000 1.300 1.00 1.00 1.00 1.00 - 2 Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 2 CRITICAL LOAD COMBINATIONS: Shear : LC 42 = D+S, V max = 1127, V design = 932 lbs Bending(+): LC #2 = D+S, 14 = 929 lbs-ft Deflection: LC 42 = D+S (live) LC k2 = D+S (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 77.6e06 lb-in2 "Live" deflection = Deflection from all non -dead loads (live, wind, snow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. Design Notes: 1. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. COMPANY Design Build Services, Inc. 2 St PROJECT 514 8th Ave N - Lot 2 5148thAve N WoodWorks' Monroe, WAA98272 Edmonds, WA 98020 (360)793-9659 Thuesen Custom Homes SOFFWARF FOR WOOD DFSfCN Oct. 16, 2019 14:01 b15.wwb Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads: Load Type Distribution Pat- tern Location [ft] Start End Magnitude Start End Unit 1 j49 Dead Partial UDL 2.04 4.04 91.9 91.9 plf 2 j49 Snow Partial UDL 2.04 4.04 141.0 141.0 plf 3 j50 Dead Trapezoidal 0.04 2.04 74.1 91.9 plf 4 j50 Snow Trapezoidal 0.04 2.04 117.2 141.0 plf Self -weight Dead Full UDL 4.6 plf Maximum Reactions (lbs) and Bearing Lengths (in) : 4'-1" Unfactored: Dead 178 190 Snow 262 278 Factored: Total 440 468 Bearing: Length 0.50* 0.50* Min re 'd 0.50* 0.50* *Minimum bearing length setting used: 1/2" for end supports b15 Lumber -soft, D.Fir-L, No.2, 4x6 (3-1/2"x5-1/2") Supports: All - Timber -soft Column, D.Fir-L No.2 Total length: 4'-1.0"; Clear span: 4'; volume = 0.5 cu.ft. Lateral support: top= full, bottom= at supports; Analysis vs. Allowable Stress and Deflection using NOS 2015: Criterion Analysis Value Design Value Unit Analysis/Desi n Shear fv = 28 Fv' = 207 psi fvFv' = 0.14 Bending(+) fb = 320 Fb' = 1345 psi fb/Fb' = 0.24 Dead Defl'n 0.01 = <L/999 Live Defl'n 0.01 = <L/999 0.13 = L/360 in 0.08 Total Defl'n 0.02 = <L/999 0.20 = L/240 in 0.09 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LCk Fv' 180 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 900 1.15 1.00 1.00 1.000 1.300 1.00 1.00 1.00 1.00 - 2 Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 2 CRITICAL LOAD COMBINATIONS: Shear : LC 42 = D+S, V max = 468, V design = 360 lbs Bending(+): LC 42 = D+S, 14 = 471 lbs-ft Deflection: LC 42 = D+S (live) LC ]f2 = D+S (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 77.6e06 lb-in2 "Live" deflection = Deflection from all non -dead loads (live, wind, snow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. Design Notes: 1. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. COMPANY Design Build Services, Inc. 20th St SE WoodWorkso Monroe, WA 98272 (360)793-9659 (360) 7 3-9659 SOFTIVAREFOR WOOD DESIGN Oct. 16, 2019 13:49 Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads: Load Type Distribution Pat- Location tft] Magnitude Unit tern Start End Start End 1 j20 Dead Full UDL 95.9 plf 2 j20 Live Full UDL 250.0 plf Self -weight Dead Full UDL 4.0 plf Maximum Reactions (Ibs) and Bearing Lengths (in) : 4'-1.91" PROJECT 514 8th Ave N - Lot 2 514 8th Ave N Edmonds, WA 98020 Thuesen Custom Homes bl7.wwb Unfactored: Dead 208 208 Live 520 520 Factored: Total 727 727 Bearing: Length 0.96 0.96 Min req'd 0.96 0.96 b17 Lumber -soft, Hem -Fir, No.2, 4x6 (3-1/2"x5-1/2") Supports: All - Timber -soft Column, D.Fir-L No.2 Total length: 4'-1.91"; Clear span: 4% volume = 0.6 cu.ft. Service: wet; Lateral support: top= full, bottom= at supports; Analysis vs. Allowable Stress and Deflection using NDS 2015: Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 42 Fv' = 116 psi fv/Fv' = 0.36 Bending(+) fb = 495 Fb' = 884 psi fb/Fb' = 0.56 Dead Defl'n 0.01 = <L/999 Live Defl'n 0.03 = <L/999 0.14 = L/360 in 0.21 Total Defl'n 0.04 = <L/999 0.20 = L/240 in 0.20 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 150 1.00 0.97 1.00 - - - - 1.00 0.80 1.00 2 Fb'+ 850 1.00 1.00 1.00 1.000 1.300 1.00 1.00 1.00 0.80 - 2 Fcp' 405 - 0.67 1.00 - - - - 1.00 1.00 - - E' 1.3 million 0.90 1.00 - - - - 1.00 0.95 - 2 CRITICAL LOAD COMBINATIONS: Shear : LC 42 = D+L, V max = 714, V design = 539 lbs Bending(+): LC 42 = D+L, M = 728 Ibs-ft Deflection: LC 42 = D+L (live) LC 42 = D+L (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 63.1e06 lb-in2 "Live" deflection = Deflection from all non -dead loads (live, wind, snow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. Design Notes: 1. Wood Works analysis and design are in accordance with the [CC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. WoodWorks° COMPANY Design Build Services, Inc. St PROJECT 514 8th Ave N - Lot 2 514 8th Ave N Monro Monroe,, WA 98272 Edmonds, WA 98020 SOFiWAREFOR WOOD DESIGN (360) 793-9659 Thuesen Custom Homes Oct. 16, 2019 14:07 c5.wwc Design Check Calculation Sheet WoodWorks Sizer 11.1.1 Loads: Load Type Distribution Location [ft] Start End Magnitude Start End Unit 1_b10 Dead Axial (Ecc. = 0.00") 899 lbs 2 b10 Snow Axial (Ecc. = 0.0011) 614 lbs 3 b3 Dead Axial (Ecc. = 0.00") 5324 lbs 4 b3 Live Axial (Ecc. = 0.00") 4822 lbs 5 b3 Snow Axial (Ecc. = 0.00") 3039 lbs Self -weight Dead Axial 41 lbs Lateral Reactions (lbs): ca W Ul (D u a "I c5 Lumber Post, D.Fir-L, No.2, 4x6 (3-1/2"x5-1/2") Support: Non -wood Total length: 9'; Clear span: 9'; volume = 1.2 cu.ft. Pinned base; Load face = width(b); Ke x Lb: 1.0 x 0.0 = 0.0 [ft]; Ke x Ld: 1.0 x 9.0 = 9.0 [ft]; Analysis vs. Allowable Stress and Deflection using NDS 2015: Criterion Analysis Value Design Value Unit Analysis/Design Axial Axial Bearing fc = 656 fc = 656 Fc' = 976 Fc* = 1708 psi psi fc/Fc' = 0.67 fc/Fc* = 0.38 Additional Data: FACTORS: F/E(psi)CD CM Ct CL/CP CF Cfu Cr Cfrt Ci LC# Fc' 1350 1.15 1.00 1.00 0.572 1.100 - - 1.00 1.00 3 Fc* 1350 1.15 1.00 1.00 - 1.100 - - 1.00 1.00 3 CRITICAL LOAD COMBINATIONS: Axial : LC #3 = D+.75(L+S), P = 12620 lbs D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load combinations: ASCE 7-10 / IBC 2015 Design Notes: 1. WoodWorks analysis and design are in accordance with the ]CC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. Pi WoodWorks° COMPANY Design Build Services, Inc. St PROJECT 514 8th Ave N - Lot 2 5148thAve N Monroe, Monroe,,WA 98272 Edmonds, WA 98020 SOFTWARE FOR WOOD DESIGN (360) 793-9659 Thuesen Custom Homes Oct. 16, 2019 14:08 c6.wwc Design Check Calculation Sheet WoodWorks Sizer 11.1.1 Loads: Load Type Distribution Location [ft] Magnitude Unit Start End Start End 1 b3 Dead Axial (Ecc. = 0.00") 3588 lbs 2 b3 Live Axial (Ecc. = 0.00") 5258 lbs 3 b3 Snow Axial (Ecc. = 0.00") 532 lbs Self -weight Dead Axial 41 lbs Lateral Reactions (lbs): N 91 91 c6 Lumber Post, D.Fir-L, No.2, 4x6 (3-1/2"x5-1/2") Support: Non -wood Total length: 9'; Clear span: 9'; volume = 1.2 cu.ft. Pinned base; Load face = width(b); Ke x Lb: 1.0 x 9.0 = 9.0 [ft]; Ke x Ld: 1.0 x 9.0 = 9.0 [ft]; Analysis vs. Allowable Stress and Deflection using NDS 2015: Criterion Analysis Value Design Value Unit Analysis/Design Axial Axial Bearing fc = 462 fc = 462 Fc' = 460 Fc* = 1485 psi psi fc/Fc' = 1.00 fc/Fc* = 0.31 -A O Additional Data: FACTORS: F/E(psi)CD CM Ct CL/CP CF Cfu Cr Cfrt Ci LC# Fc' 1350 1.00 1.00 1.00 0.309 1.100 - - 1.00 1.00 2 Fc* 1350 1.00 1.00 1.00 - 1.100 - - 1.00 1.00 2 CRITICAL LOAD COMBINATIONS: Axial : LC #2 = D+L, P = 8887 lbs D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load combinations: ASCE 7-10 / IBC 2015 Design Notes: 1. WoodWorks analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. WoodWorks° COMPANY Design Build Services, Inc. St PROJECT 514 8th Ave N - Lot 2 5148thAve N Monro Monroe,,WA 98272 Edmonds, WA 98020 SOFTWARE FOR WOOD DESIGN (360) 793-9659 Thuesen Custom Homes Oct. 16, 2019 14:09 c17.wwc Design Check Calculation Sheet WoodWorks Sizer 11.1.1 Loads: Load Type Distribution Location [ft] Magnitude Unit Start End Start End 1 b9 Dead Axial (Ecc. = 0.00") 1269 lbs 2 b9 Snow Axial (Ecc. = 0.00") 1165 lbs Self -weight Dead Axial 22 lbs Lateral Reactions (lbs): 10, W � v o m 0' 10, c17 Lumber n-ply, Hem -Fir, No.2, 2x4, 2-ply (3"x3-1/2") Support: Non -wood Total length: 10'; Clear span: 10'; volume = 0.7 cu.ft. Pinned base; Load face = width(b); Built-up fastener: nails; Ke x Lb: 1.0 x 0.0 = 0.0 [ft]; Ke x Ld: 1.0 x 10.0 = 10.0 [ft]; Repetitive factor: applied where permitted (refer to online help); Analysis vs. Allowable Stress and Deflection using NDS 2015: Criterion Analysis Value Design Value Unit Analysis/Design Axial Axial Bearing fc = 234 fc = 234 Fc' = 315 Fc* = 1719 psi psi fc/Fc' = 0.74 fc/Fc* = 0.14 Additional Data: FACTORS: F/E(psi)CD CM Ct CL/CP CF Cfu Cr Cfrt Ci LC# Fc' 1300 1.15 1.00 1.00 0.183 1.150 - - 1.00 1.00 2 Fc* 1300 1.15 1.00 1.00 - 1.150 - - 1.00 1.00 2 CRITICAL LOAD COMBINATIONS: Axial : LC #2 = D+S, P = 2456 lbs Kf = 1.00 D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load combinations: ASCE 7-10 / IBC 2015 Design Notes: 1. WoodWorks analysis and design are in accordance with the [CC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. BUILT-UP COLUMNS: nailed or bolted built-up columns shall conform to the provisions of NDS Clause 15.3. COMPANY PROJECT Design Build Services, Inc. 28119 2 St E 514 8th Ave N - Lot 2 e N WoodWorks° A Monroe, WA 98272 Monroe 982 Edmonds, WA 98020 Edmonds, s, SOFTWARE FOR WOOD DESIGN (360) 793-9659 Oct. 16, 2019 14:10 Thuesen Custom Homes j1.wwb Design Check Calculation Sheet Wood Works Sizer 11.1.1 Loads Load Type Distribution Pat- Location [ftl Magnitude Unit tern Start End Start End Loadl Dead Full UDL 16.0 plf Load2 Live Full UDL 53.3 plf Self -weight Dead Full UDL 1.3 plf Maximum Reactions (lbs): 12' 4 0' 4 12' Unfactored: Dead 104 104 Live 320 320 Factored: Total 424 424 j1 I -Joist, APA PRI, PRI-20, 1-1/2"x9-1/2" Supports: All - Non -wood Floor joist spaced at 16" c/c; Total length: 12'; Clear span: 12' Analysis vs. Allowable Stress and Deflection using NDS 2015: Criterion Analysis Value Design Value Unit Analysis/Design Shear V = 424 Vr = 1120 kips V/Vr = 0.38 Bending(+) M = 1271 Mr = 2520 kip-ft M/Mr = 0.50 Dead Defl'n 0.06 = <L/999 Live Defl'n 0.18 = L/821 0.30 = L/480 in 0.58 Total Defl'n 0.23 = L/620 0.60 = L/240 in 0.39 Additional Data: FACTORS: F/E CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Vr 1120 1.00 - - - - - - 1.00 - - 2 Mr+ 2520 1.00 - - - - - 1.00 1.00 - - 2 EI 132.0 million - - - - - - 1.00 - - 2 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D+L, V max = 424 lbs Bending(+): LC #2 = D+L, M = 1271 lbs-ft Deflection: LC #2 = D+L (live) LC #2 = D+L (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load combinations: ASCE 7-10 / IBC 2015 CALCULATIONS: Deflection: EI = 145e06 lb-in2 K= 21.97e06 lbs "Live" deflection = Deflection from all non -dead loads (live, wind, snow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. Design Notes: 1. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2015), the National Design Specification (NDS 2015), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Wood Works Sizer provides preliminary estimates for I -joist design. Each wood I -joist producer develops its own proprietary design values. Please contact the manufacturer for a custom ]-joist version of Sizer or other kjoist design software.