Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2023-1152+Manufacturer_Specifications_and_Installation_Instructions+9.12.2023_2.09.20_PM+3778512
410 wP 19.3 %T2 22.2 % EFFICIENCY T REL 25 YEAR PROTRUST L WARRANTY �F ELIGIBLE SOLAR'S MOST TRUSTED REC COMPACT PANEL SIZE LEAD-FREE ROHS COMPLIANT EXPERIENCE PERFORMANCE GENERALDATA `& Cell type: 132 half -cut REC heterojunction bifacial cells with lead-free, gapless technology, 6 strings of 22 cells in series Glass: 0.13 in (3.2 mm) solarglass with anti -reflective surface treatment in accordance with EN 12150 Backsheet: Highly resistant polymer (black) Frame: Anodized aluminum (black) Junction box: 3-part, 3 bypass diodes, lead-free IP68 rated, in accordance with IEC 62790 Connectors: Staubli MC4 PV-KBT4/KST4(4 mmz) in accordancewith IEC 62852, IP68 onlywhen connected Cable: 12 AWG (4mm2) PVwire, 43+47 in (1.1 +1.2 m) in accordance with EN 50618 Dimensions: 71.7x40 xl.2 in (19.91 ftz)/ 1821 x 1016 x 30 mm (1.85 mz) Weight: 45 Ibs (20.5 kg) Origin: Made in Singapore `ELECTRICAL DATA Power Output - PMAX(Wp) 390 Watt Class Sorting -(W) 0/+5 Nominal Power Voltage-VMPP(V) 40.6 tJ No minaIPowerCurrent-IMpp(A) 9.61 Open Circuit Voltage - Voc(V) 48.4 Short Circuit Current-Isc(A) 10.38 Power Density (W/ftz) 19.6 Panel Efficiency(%) 21.1 1821±2.5 [71.7±0.1] 28 [1.11 901 [35.51 460 [18.11 ❑ 153.7 [6.05] 1100 [43.3] } 6.0±0.2 [0.24±0.011 0 11±0.2 [0.43±0.01 ] zo.s±o.s 1200 [47.21 - [0.8±0.02] 153.7 [6.05] o 'f Product Code': RECxxxAA Pure 395 400 405 410 0/+5 0/+5 0/+5 0/+5 41.0 41.4 41.8 42.2 9.64 9.67 9.69 9.72 48.6 48.8 49.1 49.4 10.39 10.40 10.41 10.42 19.8 20.1 20.3 20.6 21.4 21.6 21.9 22.2 Power Output - PMAX(Wp) 297 301 305 308 312 Nominal Power Voltage-VMPP(V) 38.3 38.6 39.0 39.4 39.8 0 Nominal Power Current - IMPP(A) 7.77 7.79 7.82 7.83 7.85 Z Open Circuit Voltage - Voc(V) 45.6 45.8 46.0 46.3 46.6 Short Circuit Current - Isc(A) 8.38 8.39 8.40 8.41 8.42 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m2), temperature 77°F (25'C), based on a production spread with a tolerance of PMAX, Va & Ix±3%within one watt class. Nominal module operatingtemperature (NMOT: air mass AM 1.5, irradiance 800 W/nn, temperature 687 (20'C), windspeed 3.3 ft/s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. ,MAXIMUM RATINGS WARRANTY jEr Operational temperature:-40...+185°F Standard REC ProTrust Maximum system voltage: 1000V Installedbyan REC No Yes Yes Certified Solar Professional Maximum test load (front): +7000 Pa (1461bs/ft2)' System Size All r25 kW 25-500 kW Maximum test load (rear): -4000 Pa (83.5 Ibs/ftz)` Product Warranty (yrs) 20 25 25 Max series fuse rating: 25A Power Warranty (yrs) 25 25 25 Max reverse current: 25A Labor Warranty (yrs) 0 25 10 See installation manualfor mounting instructions. Power inYear 1 98% 98% 98% Design load =Test load /1.5(safety factor) Annual Degradation 0.25% 0.25% 0.25% Power in Year 25 92% 92% 92% The REC ProTrust Warranty is only available on panels purchased through an REC Certified Solar Professional installer. Warranty conditions apply. See www.recgroup.com for more details. Available from: Founded in1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar's Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia -Pacific. �. �30 [1.2] Measurements in mm [in] CERTIFICATIONS I EC 61215:2016, IEC 61730:2016, U L 61730 IEC62804 PID IEC 61701 Salt Mist IEC 62716 Ammonia Resistance UL61730 Fire Type Class 2 IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone (35mm) IEC62321 Lead-freeacc. to ROHS EU 863/2015 ISO14001, ISO9001, IEC 45001, IEC 62941 o"E 1i u�= C E 0 Int k Lead -Free TEMPERATURE RATINGS` ` M Nominal Module OperatingTemperature: 44°C (±2*C Temperature coefficient of PMAX: -0.24 %/°K Temperature coefficient ofVoc: -0.24%/°K Temperature coefficient of Isc: 0.04 %/°K 'The temperature coefficients stated are linear values DELIVERY INFORMATION Panels per pallet: 33 Panels per40ftGP/high cube container: 792 (24 pallets) Panels per 53 fttruck: 891(27 pallets) LOW LIGHT BEHAVIOUR Typical low irradiance performance of module at STC: 0 u W Irrad[ance (W/m2) REC Solar PTE. LTD. ® ^ 20Tuas South Ave. l4 REC Singapore 637312 �� post@recgroup.com www.recgroup.com of EN PHASE DATA SHEET IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming, software - defined microinverters with split -phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor -based microinverter is our proprietary application -specific integrated circuit (ASIC) which enables the microinverter to operate in grid -tied or off -grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super -fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase10 Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software. NEW Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power -on testing, enabling an industry -leading limited warranty of up to 25 years. IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer's instructions. © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, I08 microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. Easy to install • Lightweight and compact with plug-n-play connectors • Power Line Communication (PLC) between components • Faster installation with simple two -wire cabling High productivity and reliability • Produce power even when the grid is down More than one million cumulative hours of testing Class II double -insulated enclosure • Optimized for the latest high- powered PV modules Microgrid-forming • Complies with the latest advanced grid support • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21(UL 1741-SA) requirements I QBSP-DS-0002-01-E N-US-2021-10-19 IQ8 and IQ8+ Microinverters Commonly used module pairings' Module compatibility MPPT voltage range Operating range Min/max start voltage Max input DC voltage Max DC current' [module Isc] Overvoltage class DC port DC port backfeed current PV array configuration Peak output power Max continuous output power Nominal (L-L) voltage/range' Max continuous output current Nominal frequency Extended frequency range Max units per 20 A (L-L) branch circuit' Total harmonic distortion Overvoltage class AC port AC port backfeed current Power factor setting Grid -tied power factor (adjustable) Peak efficiency CEC weighted efficiency Night-time power consumption Ambient temperature range Relative humidity range DC Connector type Dimensions (HxWxD) Weight Cooling Approved for wet locations Acoustic noise at 1 m Pollution degree Enclosure Environ. category / UV exposure rating W 235 - 350 235 - 440 60-cell/120 half -cell 60-cell/120 half -cell and 72-cell/144 half -cell V 27 - 37 29 - 45 V 25 - 48 25 - 58 V 30 / 48 30 / 58 V 50 60 A 15 mA 11 0 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit A: .1 A: VA 245 300 VA 240 290 V 240 / 211 - 264 A 1.0 1.21 Hz 60 Hz 50 - 68 16 13 <5 mA III 30 1.0 0.85 leading - 0.85 lagging 97.5 97.6 97 97 mW 60 -400C to +600C (-40°F to +1400F) 4% to 100% (condensing) MC4 212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2") 1.08 kg (2.38 Ibs) Natural convection - no fans Yes <60 dBA PD3 Class II double -insulated, corrosion resistant polymeric enclosure NEMA Type 6 / outdoor CA Rule 21(UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer's instructions. (1) No enforced DC/AC ratio. See the compatibility calculator at https://Iink.enphase.com/ module -compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2021-10-19 ENPHASE DATASHEET M NA c IQ Battery 5P The IQ Battery 5P all -in -one AC -coupled system is powerful, reliable, simple, and safe. It has a total usable energy capacity of 5.0 kWh and includes six embedded grid -forming microinverters with a 3.84 kVA continuous power rating. It provides backup capability, and installers can quickly design the right system size to meet the customer needs. Dimensions Enphase 15 --ty 15-year limited warranty I I I I I I 37.9" I 38.6" I I I I I LISTED o �.o arc,. Top shield Bottom mounting bracket UL 954OA Certified Powerful Provides 3.84 kVA continuous and 7.68 kVA peak power Doubles the available power per kWh of prior generations of IQ Battery Includes six embedded IQBD-BAT Microinverters Reliable 15-year limited warranty Cools passively with no moving parts orfans Uses wired communication for fast and consistent connection Updates software and firmware remotely Simple Fully integrated AC battery system Installs and commissions easily Supports Backup, Self -Consumption, and time -of -use (TOU) modes Offers homeowners remote monitoring and control from the Enphase App Field replaceable components Safe Evaluated to UL 9540A for large scale fire testing and reduced separation distance as required in 2021 IRC R328.3.1, 2021 IFC 1207.1.5, and 2023 NFPA 85515.3.1 and 9.1.W Uses lithium iron phosphate (LFP) chemistry for maximum safety and longevity 'Follow all installation instructions when installing Enphase ESS. © 2023 Enphase Energy. All rights reserved. Enphase, the a and CC logos, IQ and certain other marks listed at https://enphase.com/trademark-usage-quidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change. IQB-5P-DSH-00010-2.0-EN-US-2023-07-26 IQ Battery 5P The IQ Battery 513 system with integrated IQ Microinverters and battery management system (BMS) with IQBATTERY-5P-IP-NA battery controller WHAT'S IN THE :O IQ Battery 5P unit IQ Battery 5P unit (1305402-US00-1-3) ID cover and conduit cover IQ Battery 5P cover with two conduit covers for the left and right sides of the unit Bottom mounting bracket and top shield Bottom mounting bracket for mounting the battery on the wall. One top shield is required for UL9540A M5 seismic screws Two M5 seismic screws for securing the battery unit on the bottom mounting bracket M4 grounding screws Two M4 grounding screws for securing the top shield on the bottom mounting bracket M5 ID cover grounding screws Two M5 ID cover grounding screws for the EMI/EMC requirement Cable ties Six cable ties for securing field cables to the unit Control (CTRL) connector Spare CTRL connector without resistor for CTRL wiring Control (CTRL) connector with resistor Spare CTRL connector with resistor for CTRL wiring Quick Install Guide (QIG) QIG for IQ Battery unit installation instructions ACCESSORIESOPTIONAL i REPLACEMENT PARTS IQBD-BAT-RMA IQBD-BAT Microinverter for field replacement B05-T02-US00-1-3-RMA IQ Battery 513 Battery unit for field replacement B05-CX-0550-0 IQ Battery 5P cover for field replacement BO5-PI-0550-0 IQ Battery 513 pedestal mount B05-CP-096-0 IQ Battery 513 conduit plates for field replacement. Includes one left -side and one right -side conduit plate BO5-WB-0543-0 IQ Battery 5P wall bracket for field replacement. Includes one bottom mounting bracket and one top shield IQBATTERY-HNDL-5 IQ Battery SP lifting handles. Includes one left -side and one right -side lifting handle B05-ACFB-080-0 IQ Battery 5P AC filter board for field replacement BO5-BMSNA-0490-0 IQ Battery 5P EMS board for field replacement B05-CANB-063-0 IQ Battery 513 control communication board for field replacement BO5-NICS-0524-0, B05-NUCS-0524-0 IQ Battery 5P control switch is preinstalled on the wiring cover for field replacement Rated (continuous) output power Peak output power Nominal voltage/range Nominal frequency/range Rated output current (@240 VAC) Peak output current (@240 VAC) Load start capability Power factor (adjustable) Maximum units per 20 A branch circuit Maximum conductor size supported Overcurrent protection device (OCPD) for 3 AWG cable Interconnection AC round-trip efficiency' 2Supported in both grid -connected and backup/off-grid operation 3 Load start capability may vary 4AC to the battery to AC at 50% power rating 3.84 kVA 7.68 kVA (3 seconds), 6.14 kVA (10 seconds) 240/211-264 VAC 60/57-63 Hz 16 A 32 A (3 seconds), 25.6 A (10 seconds) Up to 48 A LRA' 0.85 leading ... 0.85 lagging One unit (single-phase) 3AWG 80 A Single-phase 90% IQB-5P-DSH-00010-2.0-EN-US-2023-07-26 IQ Battery 5P Total capacity 5.0 kWh Usable capacity 5.0 kWh DC round-trip efficiency 96% Nominal DC voltage 76.8 V Maximum DC voltage 86.4 V Ambient operating temperature range (charging) -20°C to 50°C (-4°F to 122°F) non -condensing Ambient operating temperature range (discharging) -20°C to 55°C (-4°F to 131°F) non -condensing Optimum operating temperature range 0°C to 30°C (32°F to 86°F) Chemistry Lithium iron phosphate (LFP) Dimensions (HxWxD) 980 mm x 550 mm x 188 mm (38.6 in x 21.7 in x 7.4 in) Lifting weight 66.3 kg (146.1 Ibs) Total installed weight 78.9 kg (174 Ibs) Enclosure Outdoor-NEMA 3R IQBD-BAT Microinverter enclosure NEMA type 6 Cooling Natural convection Altitude Up to 2,500 meters (8,202 feet) Mounting Wall -mount or pedestal -mount (sold separately) Compatibility Compatible with IQ and M Series Microinverters, IQ System Controller 3/3G, IQ Combiner 5/5C, and IQ Gateway for grid -tied and backup operation Communication Wired control communication Services Backup, Self -Consumption, TOU, and NEM integrity Monitoring Enphase Installer Platform and Enphase App monitoring options; API integration CA Rule 21(UL 1741-SA), IEEE 1547:2018 (UL 1741-SE, 3rd Ed.) CAN/CSA C22.2 No.107.1-16 Compliance UL 9540, UL 9540A, UN 38.3, UL 1998, UL 991, NEMA Type 3R, AC156 EMI: 47 CFR, Part 15, Class B, ICES 003 Cell module: UL 1973, UN 38.3 Inverters: UL 62109-1, IEC 62109-2 LIMITED WARRANTY Limited warranty >60% capacity, up to 15 years or 6,000 cycles5 s Whichever occurs first. Restrictions apply IQB-5P-DSH-00010-2.0-EN-US-2023-07-26 Revision history DSH-00010-2.0 July 2023 Added battery isometric view on the first page. Editorial updates. DSH-00010-1.0 May 2023 Initial release. © 2023 Enphase Energy. All rights reserved. Enphase, the a and CC logos, IQ and certain other marks listed at https://enphase.com/trademark-usage-quidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change. IQB-5P-DSH-00010-2.0-EN-US-2023-07-26