Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2023-1152+Manufacturer_Specifications_and_Installation_Instructions+9.12.2023_3.29.25_PM+3778759
I � r 1 r 1 r r r r �r �,, ENPHASE I IQ8H \_ Y ,ei'• eENPHASE IQ8A _ �ry w,aNING^ _ A o I r r I I ENPHASE �l .�.. A-ENPHASE. P IQBM w WARNING, ATTFNTION MEMO! A g F TIPNyf y�Waffl�Rlip ENPHASE A Ip8 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation FCC Compliance This equipment has been tested and found to comply with the limits fora Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will notoccur in a particular installation. If this equipmentdoescause harmful interference to radio ortelevision reception, which can be determined byturning the equipmentoff and on, you are encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipmentand the receiver. • Connectthe equipmentinto an outlet on a circuit differentfrom thatto which the receiveris connected. • Consultthe dealeror an experienced radio/TVtechnician for help. Changes ormodifications notexpressly approved bythe party responsible forcompliance mayvoid the user's authority to operate the equipment. Other Information Product information is subjectto change without notice. All trademarks are recognized as the property of their respective owners. User documentation is updated frequently; checkthe Enphase website (enphase.com/support)forthe latest information. To ensure optimal reliabilityand to meetwarranty requirements, the Enphase Microinverter mustbe installed according to the instructions in this manual. Forwarranty text referto enphase.com/warranty. For Enphase patent information referto enphase.com/comi)anv/patents/. © 2022 Enphase Energy Inc. All rights reserved. Enphase, the Enphase logo, IQ8, IQ8+, IQ8M, IQ8A, IQ8H, IQ Gateway, IQ Combiner, IQ Microinverter, InstallerApp, Enphase App and other trademarks orservice names are the trademarks of Enphase Energy, Inc. Data subjectto change. Audience This manual is intended for use by professional installation and maintenance personnel. © 2022 Enphase Energy Inc. All rights reserved. December 2022 IQ8 / IQ8+ / IQBM / IQBA / IQBH Micro Installation and Operation Contents Important Safety Information............................................................................................................5 Readthis First...............................................................................................................................5 ProductLabels..............................................................................................................................5 Safetyand Advisory Symbols........................................................................................................5 IQ 8 Microinverter Safety Instruction.............................................................................................5 PV Rapid Shutdown Equipment(PVRSE)......................................................................................8 TheEnphase IQ System....................................................................................................................9 How the Enphase IQ Series Micros Work....................................................................................10 SystemMonitoring......................................................................................................................10 OptimalReliability.......................................................................................................................10 Easeof Design............................................................................................................................10 Planning for Microinverter Installation............................................................................................11 Compatibility...............................................................................................................................11 Grounding Considerations..........................................................................................................11 BranchCircuit Capacity ...............................................................................................................11 Utility Service Requirements.......................................................................................................12 Wire Lengths and Voltage Rise....................................................................................................12 Lightning and Surge Suppression...............................................................................................12 Partsand Tools Required...............................................................................................................13 EnphaseEquipment....................................................................................................................13 OtherItems..................................................................................................................................13 Enphase Microinverter Installation.................................................................................................14 Step 1: Position the Enphase IQ Cable........................................................................................14 Step 2: Position the Junction Box...............................................................................................15 Step 3: Mount the Microinverters................................................................................................15 Step 4: Create an Installation Map...............................................................................................16 Step5: Manage the Cabling.........................................................................................................16 Step 6: Connect the Microinverters.............................................................................................17 Step 7: Terminate the Unused End of the Cable..........................................................................17 Step 8: Complete Installation of the Junction Box.......................................................................18 Step 9: Connect the PV Modules.................................................................................................18 Step 10: Enphase Energy System Configurations.......................................................................18 Troubleshooting..............................................................................................................................23 Status LED Indications and Error Reporting...............................................................................23 LEDOperation...........................................................................................................................23 DC Resistance Low — Power Off Condition..................................................................................23 OtherFaults...............................................................................................................................24 Troubleshoot an Inoperable Microinverter...................................................................................24 Disconnect a Microinverter..........................................................................................................25 Install a Replacement Microinverter............................................................................................25 3 © 2022 Enphase Energy Inc. All rights reserved. December2022 IQ8 / IQ8+ / IQBM / IQBA / IQ8H Micro Installation and Operation Replacement Parts and Cabling......................................................................................................27 Ordering Replacement Parts.......................................................................................................27 Enphase IQ Cable Planning and Ordering...................................................................................27 Connector Spacing Options........................................................................................................27 CablingOptions...........................................................................................................................27 Enphase IQ Cable Accessories....................................................................................................27 TechnicalData................................................................................................................................29 Technical Considerations............................................................................................................29 BifacialModules..........................................................................................................................29 Specifications.................................................................................................................................30 IQ8-60-2-US Microinverter Specifications....................................................................................30 IQ8PLUS-72-2-US Microinverter Specifications...........................................................................32 IQ8M-72-2-US Microinverter Specifications.................................................................................34 IQ8A-72-2-US Microinverter Specifications.................................................................................36 IQ8H-240-72-2-US Microinverter Specifications...........................................................................38 IQ8H-208-72-2-US Microinverter Specifications...........................................................................40 IQCable Specifications...............................................................................................................42 Enphase Connector Ratings........................................................................................................42 EnphaseInstallation Map................................................................................................................43 SampleWiring Diagram..................................................................................................................44 4 © 2022 Enphase Energy Inc. All rights reserved. December2022 IQ8 / IQ8+ / IQBM / IQBA / IQBH Micro Installation and Operation Important Safety Information Read this First This manual contains important instructions for use during installation and maintenance of the IQ 8TM Series Microinverters. IMPORTANT: Enphase IQ Series Microinverters require the IQ Cable. An IQ Gateway is required to monitor performance of the IQ Microinverters. The IQ Accessorieswork onlywith Enphase IQ Series Microinverters. Product Labels The following symbols appearon the product label and are described here: WARNING: Hot surface DANGER: Refer to safety instructions NDANGER: Risk of electrical shock 10 Referto manual FE Double -Insulated Safety and Advisory Symbols To reduce the risk of electric shock, and to ensure the safe installation and operation of the Enphase IQ System, the following safety symbols appearthroughoutthisdocumentto indicate dangerous conditions and importantsafety instructions. L DANGER: This indicatesa hazardous situation, which if not avoided,will resultin death or serious injury. WARNING This indicates a situation where failure to follow instructions may be a safety hazard or cause equipment malfunction. Use extreme caution and follow instructions carefully. WARNING: This indicatesa situ ation where fa i I u re to fol I ow i nstru ctions m ay resu It i n burninjury. NOTE: This indicates information that is very importantforoptimaI system operation. Follow i nstructions closely. IQ 8 Microinverter Safety Instruction General Safetv DANGER: Risk L of electric shock. 1 Risk of fire. 4kDANGER: Risk of electric shock Only use electrical system components approved for wet locations. Only qualified personnel should install, troubleshoot, or replace Enphase Microinverters or Enphase IQ Cable and Accessories. Ensure that all AC and DC wiring is correct and that none of the AC or DC wires are pinched, shorted or damaged. Ensure that all AC junction boxes are properly closed. Do not exceed the maximum numberof microinverters in an AC branch circuitas listed in the manual. You m ust protect each m icroinverterAC branch circuitwith a 20A maximum breaker or fuse as appropriate. Do not use Enphase equipment in a manner notspecified bythe manufacturer. Doing so may cause death or injury to persons or damage to equipment. Be aware that installation of this equipment includes risk of electric shock. © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQBM / IQBA / IQBH Micro Installation and Operation The DC conductors of this photovoltaic system are ungrounded and maybe energized. Always de -energize the AC branch circuit before servicing. Never disconnectthe DC or AC connectors under load. �J WARNINGS: Before installing or using the Enphase Microinverter, read all instructions and cautionary markings in the technical description, on the Enphase equipmentand on the photovoltaic (PV) equipment. Do not connect Enphase Microinverters to the grid or energize the AC circuit(s) until you have completed all of the installation procedures and have received approval from the electrical utility. When the PV array is exposed to light, DC voltage is supplied to the power conversion equipment(PCE). Risk of equipmentdamage. Enphase male and female connectors mustonly be mated with the identical type and brand of male/female connector. NOTES: To ensure optimal reliability and to meetwarranty requirements, install the Enphase equipment according to the instructions in this manual. DANGER: Risk of electric shock. Always de -energize the AC branch circuit before servicing. Never disconnect the DC or AC connectorswhileunderload. Protection against lightning and resulting voltage surge mustbe in accordancewith local standards. Perform all electrical installations in accordance with all applicable local electrical codes, such as: the Canadian Electrical Code, Part 1; ANSI requirements; and NPFA 70 (NEC). Microinverter Safety The chassis of the Enphase Microinverter is the heat sink. Under normal operating WARNING: Risk conditions, the temperature could be 20° C above ambient, but underextreme conditions of skin burn. the m icroinverter can reach a temperature of 90' C. To reduce risk of burns, use caution when working with microinverters. DANGER: Risk of L4fire. The DC conductorsofthe PV module mustbe labeled "PV Wire" or "PV Cable" when paired with the Enphase Microinverter. DANGER: Risk of Only qualified personnel may connectthe Enphase Microinverterto the utility grid. electric shock. L� Risk of fire. Do not attemptto repairthe Enphase Microinverter; it contains no user -serviceable parts. If itfails, contact Enphase Customer Support to obtain a return merchandise authorization (RMA) numberand start the replacement process. Tam pering with or opening the Enphase Microinverterwill void the warranty. WARNING: Risk Install the microinverterunderthe PV module to avoid direct exposure to rain,UV, andother of equipment harmful weather events. Always install the m icroi nverter bracket side up. Do not mountthe damage. m icroinverter upside down. Do not expose the AC or DC connectors (on the Enphase IQ Cable, PV module, orthe m icroinverter)to rain or condensation before the connectors are mated. The maximum open circuitvoltage of the PV module mustnotexceed the specified maximum input DC voltage of the Enphase Microinverter. Referto the Enphase Co patibiIity Calculator at: https://enphase.com/en-us/support/module-compatibility to verify PV module electrical com patibility with microinverter. Use IQ8 Series microinverters only with com patible PV modules as per Enphase Compatibility Calculator. Using electrically incompatible PV module voids the Enphase warranty. WARNING: Risk You mustmatchthe DC operating voltage range of the PV module with the allowable input of equipment voltage range of the Enphase Microinverter. damage. The Enphase Microinverter is not protected from damage due to moisture trapped in cabling systems. Never mate m icroinverters to cables that have been left disconnected and exposed to wet conditions. This voids the Enphase warranty. WARNING: Risk The Enphase Microi nverter functions only with a standard, compatible PV module with of equipment appropriate fill -factor, voltage, and current ratings. Unsupported devices include smartPV damage. modules,fuel cells,wind orwater turbines, DC generators, and non-Enphase batteries. These devices do not behave like standard PV modules, so operation and compliance are not guaranteed. These devices mayalso damage the Enphase Microinverter by exceeding its electrical rating, making the system potentially unsafe. © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQBM / IQBA / IQBH Micro Installation and Operation NOTES: The Enphase Microinverterhas adjustable voltage and f req u e n cy tri p points that may need to be set, depending upon local requirements. ContactEn1)hase CustomerSu1) port for required modifications as per local requirements Enphase IQ Cable Safety 4 DANGER: Risk of Do not install the Enphase IQ Cable term inatorwhile power is connected. electric shock. WARNING: Risk of When stripping the sheath from the IQ Cable, make sure the conductors are not damaged. Q electric shock. Risk If the exposed wires are damaged, the system may not function properly. of fire. Do not leave AC connectors on the IQ Cable uncovered foran extended period. You must cover any unused connectorwith a sealing cap. Make sure protective sealing caps have been installed on all unused AC connectors. Unused AC connectors are live when the system is energized WARNING: Use the terminator only once. If you open the term inatorfollowing installation, the latching mechanism is destroyed. If the latching mechanism is defective, donotuse the terminator. Do not circumvent or manipulate the latching mechanism. When installing the Enphase IQ Cable, secure any loose cable to minimize tripping hazard. NOTES: When looping the Enphase IQ Cable, do not form loops smallerthan 12 cm (4.75 inches) in diameter. Provide supportfor the Enphase IQ -Cable every 1.8 m (6 ft). If you need to remove a sealing cap, you mustuse the Enphase Disconnect Tool. When installing the Enphase IQ Cable and accessories, adhere to the following: • Do not expose the terminatorcap or cable connections to directed, pressurized liquid (water jets, etc.). • Do not expose the terminator or cable to continuous immersion. • Do not expose the term inatorcap or cable connections to continuous tension (e.g., tension due to pulling or bending the cable nearthe connection). • Use only the connectors provided. • Do not allow contamination ordebris in the connectors. • Use the terminatorcap and cable connections onlywhen all parts are presentand intact. • Do not install or use in potentially explosive environments. • Do not allow the term inatorto come into contact with open flame. • Fit the terminatorcap using onlythe prescribed tools and in the prescribed manner. • Use the terminatorto seal the conductorend of the Enphase IQ Cable; no other method is allowed. © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation PV Rapid Shutdown Equipment(PVRSE) This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC-2014, NEC-2017 and NEC-2020 section 690.12, and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors,when installed according to the following requirements: • Microinverters and all DC connections must be installed inside the array boundary. Enphase furtherrequiresthatthe microinvertersand DC connections be installed underthe PV module to avoid direct exposure to rain, UV, and otherharmful weatherevents. • The array boundary is defined as 305 m m (1 ft.) from the array in all directions, or 1 m (3 ft.) from the pointof entry inside a building. This rapid shutdown system mustbe provided with an initiating device orstatus indicator, installed in a location accessible tofirst repsonders. Alternatelyitmustbeconnected toanautomaticsystemthat initiates rapid shutdown in the event a system disconnect or other emergencysystem is activated. The initiatorshall be listed and identified asa disconnecting means that plainly indicates whether it is in the "off"or"on" position. Exam plesare: • Service disconnecting means • PV system disconnecting means • Readily accessible switch or circuit breaker The handle position of a switch or circuit breaker is suitable for use as an indicator. Refer to NEC or CSA C22.1-2018for more information. Additionally, in a prominent location nearthe initiator device, a placard or label must be provided with a permanent marking including the following wording: 'PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN' The term'PHOTOVOLTAIC' maybe replaced with 'PV.' The placard, label, or directory shall be reflective, with all letters capitalized and having a minimum heightof 9.5 mm (3/8") in white on red background. © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation The Enphase IQ System The Enphase IQ System includes: Enphase IQ8, IQ8+, IQ8M, IQ8A and IQ8H Microinverters:The smartgrid ready IQ Series Micros convert the DC output of the PV module into grid-com pliantAC power. • Enphase IQ Gateway (ENV-IQ-AM1 -240): The Enphase IQ Gateway is a communication devicethat provides network access to the PV array. The IQ Gateway collects production and performance data from the Enphase IQ Microinverters over on -site AC powerlinesandtransmitsthe data to Enphase through an internetor cellular modem connection. The IQ Gateway is capable of monitoring up to 600 Enphase IQ Microinverters and up to 39 Enphase IQ Batteries. For details, referto Enphase IQ Gateway Installation and Operations Manual. NOTE: All 208 VAC installations require thatyou use the Enphase IQ Gateway to commission the Enphase Microinverters to propagate correctgrid profile settings for208 VAC trip points. Enphase Installer platform Web -based monitoring and management software: Installers can use the Enphase Installer Platform to view detailed performance data, manage multiple PV systems, and remotely resolve issues that mightimpactsystem performance. Find out more at enphase.com/enlighten. Enphase Installer App for iOS and Android devices: It allows installers to configure the system while onsite, eliminating the need fora laptop and improving installation efficiency. You can use the app to: o Connectto the IQ Gateway over a wireless network for faster system setup and verification o View and email a sum mary reportthat confirms a successful installation o Scan device serial numbersand sync system information with the Enphase Installer Platform • Enphase IQ Battery • Enphase Field Wireable connectors (Q-CONN-1OF and Q-CONN-10M): Make connections from any IQ Cable or open Field Wireable connector. © 2022 Enphase Energy Inc. All rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation This manual describes the safe installation and operation of the Enphase Microinverter. NOTE: To ensure optimal reliabiIityand to meet warranty requi rem ents, the Enphase Microinvertermustbe installed according to the instructions in this manual. How the Enphase IQ Series Microinverters Work The Enphase Microinvertermaximizes energy production by using a sophisticated Maximum Power Point Tracking (MPPT) algorithm. Each Enphase Microinverterindividually connects to one PV module in your array. This configuration enables an individual MPPT to control each PV module, ensuring that maximum power available from each PV module is exported to the utility grid regardless of the performance of the other PV modules in the array. While an individual PV module in the array maybe affected by shading, soiling, orientation, or PVmodulemismatch, each Enphase Microinverterensures top performance for its associated PV module. Enphase IQ :....... Enphase lQ Enphase Gateway Battery I:� qpp i System Monitoring Once you install the Enphase IQ Gateway and provide an internet connection through a broadband router or modem, the Enphase IQ Microinverters automatically begin reporting to the Enphase Installer Platform. The Enphase Installer Platform presents currentand historical system performance trends and informs you ofPVsystem status. Optimal Reliability Microinverter systems are inherently more reliable than traditional inverters. The distributed nature of a m icroinverter system ensures thatthere is no single pointof system failure in the PV system. Enphase Microinverters are designed to operate at full powerat am bienttem peratures as high as 60°C (140°F). Ease of Design PV systems using Enphase Microinverters are very simple to design and install. You will not need string calculations orcum bersome traditional inverters. You can install individual PV modules in any combination of PV module quantity, type, age, and orientation. Each m icroinverter quickly mounts on the PV racking, directly beneath each PV module. Low voltage DC wires connect from the PV module directly to the co -located microinverter, eliminating the risk of personnel exposure to dangerously high DC voltage. 10 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation Planning for Microinverter Installation The Enphase IQ8 Microinverter is compatible with 60-cell PV modules, and the IQ8+, IQ8M, IQ8A and IQ8H MicroinvertersupportPV moduleswith 54-, 60-, 66-, or 72-cell PV mod ules.AlI of them install quickly and easily. Them icroinverter housing is designed for outdoor installation and complies with the NEMA250, type 6 environmental enclosure rating standard. NEMA 6 rating definition: indoor or outdoor use primarily to provide a degree of protection against hose -directed water, the entry of water during occasional temporary submersion at limited depth, and damage from external ice formation. The Enphase IQ Cable is available with connector spacing options to accommodate installation of PV modules in portrait or landscape orientation. For Enphase IQ Cable ordering information, see "Enphase IQ Cable Planning and Ordering" on page 28. Compatibility The Enphase IQ Series Microinverters are electrically compatible with PV modules as listed in the following table. For specifications, see "Technical Data" starting on page 30 of this manual. You can referto the Enphase Compatibility Calculatorat: enphase.com/en-us/support/module-compatibilitvto verify PV module electrical compatibility. To ensure mechanical compatibility, be sure to order the correct connector type for both microinverter and PV module from your distributor. WARNING: Risk of fire. The PV module DC conductors must be labeled "PV Wire" or "PV Cable" to comply with NECfor Ungrounded PV Power Systems. Microinverter Model Connector Type PV Module Cell Count IQ8-60-2-US I MC-4 locking type Pair with 60 cell /120-half-cell modules IQ8PLUS-72-2-US Pair with 54-cell/108 half -cell, 60 cell / 120- half-cell, 66 cell, or 72 cell / 144-half-cell IQ8M-72-2-US IQ8A-72-2-US IQ8H-240-72-2-US IQ8H-208-72-2-US Grounding Considerations The Enphase Microinverter models listed in this guide do not require grounding electrode conductors (GEC), equipment grounding conductors (EGC), or grounded conductor (neutral). Your Authority Having Jurisdiction (AHJ) may require you to bond the mounting bracketto the racking. If so, use UL2703 hardware orstar washers. The microinverteritself has Class II double -insulated rating, which includes ground fault protection (GFP). To support GFP, use only PV modules equipped with DC cables labeled PV Wire or PV Cable. Branch Circuit Capacity Plan your AC branch circuits to meetthe following lim its for maxim urn numberof m icroinverters per branch when protected with a 20 am p (maxim um) over current protection device (OCPD). Maximum* IQ8 Micros per AC branch circuit (240 VAC) Maximum* IQ8+ Micros per AC branch circuit (240 VAC) Maximum* IQ8M Micros per AC branch circuit (240 VAC) 16 13 11 Maximum* IQ8A Micros per AC branch circuit (240 VAC) Maximum* IQ8H Micros per AC branch circuit (240 VAC) Maximum* IQ8H Micros per AC branch circuit (208 VAC) 11 10 9 NOTE: *Limits may vary. Refer to local requirements to define the number of microinverters per L.J branch in your area. 11 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation Utility Service Requirements The En phase IQ Series Microinverters work with single-phase service. Measure AC line voltages at the electrical utility connection to confirm that it is within the ranges shown: 240 Volt AC, Single Phase L1 to L2 211 to 264 VAC L1, L2 to ground 106to 132 VAC 208 Volt AC, Single Phase L1 to L2 183 to 229 VAC L1, L2 to ground 106to 132VAC NOTE: All 208 VAC installations require thatyou use the Enphase IQ Gateway to commission the Enphase Microinvertersto propagate correct grid profile settingsfor208 VAC trip points. Wire Lengths and Voltage Rise When planning the system, you mustselect the appropriate ACconductorsize to minimize voltage rise. Selectthe correct wire size based on the distance from the beginning of the microinverterAC branch circuitto the breakerin the load center. Enphase recommends a voltage rise total of less than 2% forthe sections from the m icroinverterAC branch circuit to the breakerin the load center. Enphase provides guidance aboutchoosing wire size and maximum conductor lengths in the Voltage Rise Technical Brief ateniphase.com/suppo Refer to this brief for voltage rise values in Enphase IQ Cables and on how to calculate voltage rise in other wire sections of the system. Standard guidelines forvoltage rise on feeder and AC branch circuit conductors might not be sufficientfor microinverterAC branch circuits that contain the maximum allowable microinverters. This is due to high inherent voltage rise on the AC branch circuit. Best practice: Center -feed the branch circuit to minimize voltage rise in a fully populated branch. This J practice greatly reduces the voltage rise as com pared with an end -fed branch. To center -feed a branch, t� divide the circuit into two sub -branch circuits protected by a single OCPD. Lightning and Surge Suppression Enphase Microinverters have integral surge protection, greater than most traditional inverters. However, if the surge has sufficient energy, the protection built into the m icroinverter can be exceeded, and the equipmentcan be damaged. Forthis reason, Enphase recom mends thatyou protect your system with a lightning and/or surge suppression device. In addition to having some level of surge suppression, it is also importantto have insurance that protects against lightning and electrical surges. Enphase has tested the following devices: • Leviton 51110-SRG • Schneider SauareD HEPD50 NOTE: Protection against lightning and resulting voltage surge must be in accordance with local standards. 12 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQBM / IQBA / IQBH Micro Installation and Operation Parts and Tools Required In addition to the microinverters, PV modules, and racking, you will need the following: Enphase Equipment • Enphase IQ Gateway: Required to monitorproduction. IQ Gateway (model ENV-IQ-AM1-240) communications gateway or IQ Combiner (model X-IQ-AM1-240-B, X-IQ-AM1-240-2, X-IQ- AM1-240-3, X- IQ-AM 1-240-3C). • Enphase Installer App: Download the Enphase Installerapp, open it, and log into your 2V❑ Enphase Installer Platform account. Use it later to scan m icroinverter serial numbersand connectto the IQ Gateway to track system installation progress. To download, go to https://enphase.com/installers/apps or scan the QR code at right. 0 • Tie wraps or IQ Cable Clips (Q-CLIP-100) • Enphase Sealing Caps (Q-SEAL-10) for any unused drops on the Enphase IQ Cable. • Enphase Terminator (Q-TERM-10) typically two needed per branch circuit. • Enphase Disconnect Tool (Q-DISC-10) • Enphase Field Wireable Connectors (male and female: Q-CONN-10M and Q-CONN-10F) • Enphase IQ Cable: Cable Model Connector Spacing PV Module Orientation Connector Count per box Q-12-10-240 1.3m Portrait 240 Q-12-17-240 2.Om Landscape (60-cell) 240 Q-12-20-200 2.3m Landscape (72-cell) 200 Other Items • AC junction box • Number2 and 3 screwdrivers • Wire cutters, voltmeter • Torque wrench, sockets, wrenches for mounting hardware 13 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQBM / IQBA / IQBH Micro Installation and Operation Enphase Microinverter Installation Installing the Enphase IQ Series Microinverters involves several key steps. Each step listed here is detailed in the following pages. Step 1: Position the Enphase IQ Cable Step 2: Position the Junction Box Step 3: Mount the Microinverters Step 4: Create an Installation Map Step 5: Manage the Cabling Step 6: Connect the Microinverters Step 7: Terminate the Unused End of the Cable Step 8: Complete Installation of the Junction Box Step 9: Connect the PV Modules Step 10: Energize the System Horizontal Mount I Step 1: Position the Enphase IQ Cable A. Plan each cable segmentto allow drop connectors on the Enphase IQ Cable to align with each PV module. Allow extra length for slack, cable turns, and any obstructions. B. Mark the approximate centers of each PV module on the PV racking. C. Lay out the cabling along the installed racking forthe AC branch circuit. D. Cut each segmentof cable to meetyourplanned needs. 14 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation / 1-\WARNING: When transition ing between rows, secure the cable to the rail to prevent cabled am age or connector damage. Do not count on connectorto withstand tension. Step 2: Position the Junction Box A. Verify that AC voltage at the site is within range. Service Type and Voltage: L1-L2 240 VAC Split -Phase I 211 to 264 VAC 208 VAC Single -Phase I 183 to 229 VAC L] NOTE: All 208 VAC installations require thatyou use the Enphase IQ Gateway to commission the Enphase Microinvertersto propagate correct grid profile settingsfor208 VAC trip points. B. Install a junction box at a suitable location on the racking. C. Provide an AC connection from the junction box back to the electricity network using equipment and practices as required by local jurisdictions. Step 3: Mount the Microinverters A. Mount the m icroinverter horizontally bracketside up or vertically • Always place the microinverterunderthe PV module, protected from directexposure to rain, sun, and other harmful weather events. Allow a minimum of 1.9 cm (3/4") between the roof and the microinverter. Also allow 1.3 cm (1/2") between the back of the PV module and the top of the microinverter. • For vertical mount, also maintain > 30 cm (12") clearance from the edges of the PV module to protect the m icroinverter from directexposure to rain, UV, and other harmful weatherevents. ,\ WARNING: Install the microinverterunderthe PV module to avoid direct exposure to rain, UV, and other U harmful weather events. Do not mountthe m icroinverter upsidedown. B. Torque them icroinverterfasteners as follows. Do not over torque. • 6 mm (114") mounting hardware:5 N m (45 to 50 in-lbs.) • 8 mm (5/16") mounting hardware:9 N m (80 to 85 in-lbs.) • When using UL 2703 mounting hardware, use the manufacturer's recommended torque value Horizontal mount DC Connector J0 AC Connector Vertical mount 15 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQBM / IQBA / IQBH Micro Installation and Operation Step 4: Create an Installation Map The En phase Installation Map is a diagram of the physical location of each microinverterin your PV installation. Copy or use the blank m a p on page 43 to record microinverter placement for the system or provide your own layout if you require a largeror more intricate installation map. Each Enphase Microinverter, IQ Gateway, and IQ Battery has a removable serial numberlabel. Build the installation map by peeling the serial number labels from the m icroinverter mounting plates and placing the labels on the map. You will also place the Enphase IQ Gateway and IQ Battery serial numberon the map after installation. After you have created the installation map, use the Enphase InstallerApp mobile app to record serial numbers and configure the system. For details, referto "Detect the Microinverters" in the help topics of the Enphase Installerapp. A. Peel the removable serial number label from each microinverterand affix itto the respective location on the paper installation map. B. Peel the label from the IQ Gateway and any Enphase IQ Battery (if installed)and affix itto the installation map. C. Always keep a copy of the installation map for your records. Affix serial number labels Step 5: Manage the Cabling A. Use cable clips or tie wraps to attach the cable to the racking. Leave no more than 1.8 m (6 ft) between cable clips or tie wraps. Cable clip B. Dress any excess cabling in loops so that it does not contact the roof. Do not form loops smallerthan 12 cm (41/4 ") in diameter. ,\ WARNING: Tripping Hazard. Loose cables can become a tripping hazard. Dress the Enphase IQ Cable to minimize this potential. 16 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation Step 6: Connectthe Microinverters A. Connect the micro inverter. Listen fora click as the connectors engage. B. Cover any unused connector with En phase Sealing Caps. Listen fora click as the connectors engage. WARNING: Risk of electric shock. Risk off ire. Install sealing caps on all unused AC connectors as these connectors become live when the system is energized. Sealing caps are required for protection against moisture ingress. LNOTE: If you need to remove a sealing cap, you mustuse the Enphase Disconnect Tool. See "Disconnecta Microinverter" on page 25. Step 7: Terminate the Unused End of the Cable Terminate the unused end of the Enphase IQ Cable asfollows. A. Remove 13 mm ('/z inch) of the cable sheath from the conductors. Use the terminator loop to measure 13 mm. B. Slide the hex nut onto the cable. There is a grommetinside of the hex nut that should remain in place. C. Insert the cable into the terminator body so that each of the two wires land on opposite sides of the internal separator. Terminator Body D. Insert a screwdriverinto the slot on the top of the terminatorto hold it in place and torque the nut to 7 N m. 17 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation E. Hold the terminator body stationary with the screwdriver and turn only the hex nut to prevent the conductors from twisting out of the separator. UNOTE: Turn onlythe hex nut to prevent conductors from twisting out of the separator. F. Attach the terminated cable end to the PV racking with a cable clip or tie wrap so that the cable and term inatordo not touch the roof. /.\ WARNING: The terminator cannot be re -used. If you unscrewthe U nut, you mustdiscard the terminator. Step 8: Complete Installation of the Junction Box A. Connectthe Enphase IQ Cable into the junction box. B. Refer to the wiring diagrams on page 44 for more information. Wire colors are listed in the following table. Wire Colors L1-Black I L2-Red Step 9: Connectthe PV Modules WARNING: Electrical shock hazard. The DC conductors of this photovoltaic system are ungrounded and may be energized. A. If required, attach the Enphase DC bulkhead adaptors to the microinverters. Make sure they are fully seated. Do not reverse the adaptor connections. B. Connectthe DC leads of each PV module to the DC inputconnectorsof the corresponding microinverter. C. Check the LED on the connector side of them icroinverter. The LED flashes six times when DC poweris applied. D. Mount the PV modules above the m icroinverters. Step 10: Enphase EnergySystem Configurations Following are common system configurations possible with Enphase Energy System using IQ8 PV (IQ8/ IQ8+ /IQ8M /IQ8A /IQ8H) Microinverters. - PV Solar Grid Tied - PV Solar Grid Agnostic - PV Solar + Storage - PV Solar + Generator - PV Solar + Storage + Generator Based on System configuration Enphase Energysystem technology systems include following Enphase products- . Enphase IQ Battery system is an all -in -one AC coupled storage system that includes embedded, grid -forming multimode microinverters. You can connect multiple IQBattery systems to maximize potential backup for homes. The IQ Battery 3 storage system provides flexibility to customers to start small and add capacity incrementally. 18 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation • Enphase IQ System Controller R2 The Enphase Energy System includes the IQ System Controller TM smartswitch with Microg rid Interconnection Device (MID) capability, which consolidates interconnection equipment into a single enclosure and streamlines grid-independentcapabilities of PV and storage installations by providing a consistent, pre -wired solution for residential applications. Along with MID functions, it includes PV, storage, and generator input circuits. It allows IQ Battery storage systems to form an intentional island (per IEEE 1547.4 definition) and contains neutral -forming transformer (NFT) to enable 120/24O Voperation in backup mode. • Enphase Wireless communication kit enables direct communication between IQ Battery, IQ System Controller, and the Gateway using 2.4 GHz frequency. The kit is connected to one of the USB ports on the IQ Gateway. • An Enphase Mobile Connect cellular modem is required unless already presentto ensure the best perform anceofyour system. The celIularmodem connects toa USB port on the IQ Gateway. • For new or retrofit systems with IQ -Series solar microinverters: 0 IQ8 PV (IQ8/ IQ8+ /IQ8M /IQ8A /IQ8H) Series Microinverters and accessories. Enphase Energy System technology is fully corn patible with IQ8 Series Microinverters; 0 IQ Gateway, a communications gatewaythatcan communicate with IQ8 Series Microinverters, IQ Batteries, and the IQ System Controller. It collects system performance information and transm its that information overthe internetto Enphase's cloud. An IQ Gateway is required for Enphase Energy systems with IQ -Series microinverters. Note the IQ Gateway is included in an Enphase IQ Combiner. 0 IQ Combiner Series consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It includes the Enphase IQ Gateway. Install the new communication kit in any IQ Com binerto enable wireless communication with Enphase IQ Battery and IQ System Controller. Enphase Energy System PV Solar Grid Tied: . I / O\ ENPHASE CLOUD Enphase Installer WT O A. WIFI/Ethernet & Cellular IQ8PV i i I AC Power Line ---------------------------- PLC Over AC Line IQ GATEWAY +COMMSKIT +CELLMODEM AC PV Combiner Main Service Panel 19 Home Loads For Grid Tied mode, post IQ 8PV Microinverter installations energize the system as follows: A. Turn ON the AC disconnect or circuit breakerfor the branch circuit. B. Turn ON the main utility -grid AC circuit breaker. Your system starts producing power after a five-minute wait time. C. Check the LED on the connector side of them icroinverter: LED Color I Indicates Flashing green Normal operation. AC grid function is normal and there is communication with the IQ Gateway Flashing orange I The AC grid is normal butthere is no communication with the IQ Gateway Flashing Red I The AC grid is either not present or not within specification Solid Red There is an active "DC Resistance Low, Power Off Condition." To reset, see "DC Resistance Low — Power Off Condition" on page 23. Refer to the Enphase IQ Gateway Quick Install Guide to install the IQ Gateway and set up system monitoring and grid managementfunctions. 19 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation Enphase Energy System PV Solar Grid Agnostic: ♦ I / _ O — ENPHASE 6 Enphase / I f� CLOUD [j Installer App WiFi/Ethernet In Premise Wireless 8 Cellular ,___________________________i IQBPV y i v AC Power Line IQGATEWAY COMMSKIT PLC Over AC Line +CELLMODEM IQ SYSTEM Main CONTROLLER Service AC PV Combiner Panel Home Loads \= In the PV Solar Grid Agnostic configuration in the Enphase Energy System, IQ System controller smart switch is installed on the line -side of them ain load panels. This allows a properly sized Enphase Energy system to provide power to all loads in them ain load panel in the event of a grid outage and PV solar presence. In this configuration, the IQ System Controller can be configured with amain breakerto act as the service disconnecting means. The PV system shall be interconnected to the IQ System Controlleron a dedicated breaker. This configuration typically supports larger PV system sizes and may allow avoiding expensive utility service and/or main service panel upgrades. System commissioning fora grid agnostic configuration should be done with grid power present. During IQ8 PV installation, please ensure all relays are open from main panel and IQ System Controller. When commissioned, the IQ System Controller gets powered on from grid side of the MID (Microgrid Interconnect Device); it closes the MID relay and PV relay. IQ8 PV shall start producing power in grid tied mode with IQ Gateway poweron. Follow the Enphase Energy system commissioning process using Enphase InstallerAppforsystem commissioning. Enphase Energy System PV Solar + Storage - Whole Home Backup Configuration: I / OENPHASELOEnphase � m CUD aInstaller App V�*I WiFi/Ethernet In Premise Wireless a Cellular IQSPV + y � AC Power Line IQ GATEWAY COMM KIT PLC Over AC Line +CELLMODEM IQSYSTEM Main CONTROLLER Service AC PV Combiner Panel IQ nl�nl BAT ERY In Premise Wireless Home Loads In the whole home (main load panel) backup configuration, IQ System Controller is installed on the line -side of the main load panels rated up to 200A. This allows a properly sized Enphase Energy System to provide power to all loads in the main load panel in the event of a grid outage. In this configuration, the IQ System Controllercan be configured with a main breakerto act as the service disconnecting means. The PV system can be interconnected to the IQ System Controlleron a dedicated breakeror maybe interconnected to the main load panel. This configuration typically supports 20 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation larger PV and storage system sizes and may allow avoiding expensive AIityservice and/or main service panel upgrades. The above configuration can also work with a generator connected to IQ System Controller with or without IQ Battery. Below two images explain the connection configuration. Enphase Energy System PV Solar + Generator Configuration: I , ENPHASE I('� Enphase O� CLOUD I "„�, InstallerApp WiFi/Ethernet In Premise Wireless 8. Cellular r IOBPV + + r AC Power Line IQ GATEWAY +COMMSKIT PLC Over AC Line +CELLMODEM IQSYSTEM Main CONTROLLER Service AC PV Combiner Panel e o Generator Home Loads Enphase Energy System PV Solar + IQ Battery + Generator Configuration: O\ ENPHASE Enphase CLOUD InstallerApp WiFi/Ethernet In Premise Wireless & Cellular IC8PV y i i AC Power Line IQGATEWAV +COMMSKIT PLC Over AC Line +CELLMODEM IQSYSTEM Main CONTROLLER Service AC PV Combiner Panel 0 0 Generator Q i ^n �1 BATTERY In Premise Wireless Home Loads Set Up and Activate Monitoring Refer to the Enphase IQ Gateway Quick Install Guide to install the IQ Gateway and set up system monitoring and grid managementfunctions. This guide leads you through the following: • Connecting the Gateway • Detecting devices • Connecting to Enphase Installer Platform • Registering the system • Building the virtual array 21 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation NOTE: When the utility requires a profile other than the default IEEE 1547 (for example grids managed by Hawaii Electric Industries [HEI] including HECO) you must selectan appropriate grid profile for your installation. You can set the grid profile through Enphase Installer Platform, during system registration, orthrough Enphase InstallerApp at any time. You must have an Enphase IQ Gateway to set or change the grid profile. For more information on setting orchanging the grid profile, referto the Enphase IQ Gateway Installation and Operation Manual at enphase.com/support. 22 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation Troubleshooting Follow all the safety measures described throughout this manual. Qualified personnel can use the following troubleshooting steps if the PV system does not operate correctly. _\ WARNING: Risk of electric shock. Do not attemptto repairthe Enphase Microinverter; it contains / LU\ no user -serviceable parts. If it fails, contact Enphase Customer Support to obtain an RMA (return merchandise authorization) numberandstartthe replacement process. Status LED Indications and Error Reporting The following section describes LED indications. LED Operation LED Color I Indicates Flashing green Normal operation. AC grid function is normal and there is communication with the IQ Gateway Flashing orange The AC grid is normal butthere is no communication with the IQ Gateway Flashing Red The AC grid is either not presentor not within specification Solid Red There is an active "DC Resistance Low, Power Off Condition." To reset, see "DC Resistance Low — Power Off Condition" below. The status LED on each m icroinverter lights green about six seconds after DC power is applied. It remains lit solid fortwo minutes, followed by six green blinks. After that, red blinks indicate that no grid is present ifthe system is not yet energized. Any short red blinks after DC power is first applied to the microinverterindicate afailure during microinverterstartup. DC Resistance Low— Power Off Condition For all IQ Series models, a solid red status LED when DC power has been cycled indicates the microinverter has detected a DC Resistance Low— Power Off event. The LED will remain red and the faultwill continue to be reported by the Gateway until the error has been cleared. An insulation resistance (IR) sensor in the microinverter measures the resistance between the positive and negative PV inputs to ground. If either resistance drops below a threshold, the microinverterstops power production and raises this condition. This may indicate defective module insulation, defective wiring or connectors, moisture ingress, ora similarproblem. Although the cause may betemporary,this m icroinverter condition persists until the sensoris manuallyreset. An IQ Gateway is required to clear this condition. The condition clears on operator com mand unless its cause is still present. If a m icroinverter registers a "DC Resistance Low- Power Off' condition, you can attemptto clearthis condition. If the condition does not clear after you perform the following procedure, contact Enphase Customer Support at enphase.com/en-us/sur)port/contact. There aretwo ways to send a clearmessageto the microinverter. Notethatthe conditionwill not clear after sensor reset if the cause of the failure is still present. If the condition persists, contact your installer. Method 1: Clear this Error Using Enphase Installer Platform • Log in to Enphase Installer Platform and access the system. • Clickthe Events tab. The next screen shows a current "DC Resistance Low - Power Off' condition forthe system. • Click DC Resistance Low -Power Off. • Where "n" is the num berof affected devices, click n devices (show details). • Clickthe serial num berof the affected microinverter. • Click Reset DC Resistance Low - Power Off Sensor. • The system displays, "A DC Resistance Low- Power Off reset task was issued on [date and time] forthis microinverterand is still pending." 23 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation Method 2: Use Enphase Installer App to Clear the Condition On the list of detected microinverters, a green dot or red square appears to the leftof each microinverterserial number. A green dot indicates Status OK. A red square indicates an event forth at micro inverter. • Tap the °0 to the leftofthe serial numbertoview details for a microinverterevent. • If them icroinverter status shows that there is an active DC Resistance Low —Power Off condition, tap the © to send the clear message to the affected m icroinverter. The app then indicates that a clear message was sent. Other Faults All other faults are reported to the Gateway. Refer to the Enphase IQ Gateway Installation and Operation Manual at enphase.com/support for troubleshooting procedures. Troubleshoot an Inoperable Microinverter To troubleshoot an inoperable m icroinverter, follow the steps in the order shown /\ WARNING: Risk of electric shock. Always de -energize the AC branch circuit before servicing. Never �• \) disconnectthe DC connectors under load. WARNING: The Enphase Microinverters are powered by DC powerfrom the PV modules. Make sure you 1 disconnectthe DC connections and reconnectDC powerand then watch forthe solid green about six seconds afterconnectionto DC power. A. Make sure AC breakers and disconnects are closed. B. Check the connection to the utility grid and verify that the utility voltage is within allowable ranges. Verify that AC line voltages at all solar power circuit breakers at the load center and su bpanels are within the ranges shown in the following table: 240 Volt AC, Single Phase L 1 to L2 211 to 264 VAC L1, L2 to ground 106 to 132 VAC 208 Volt AC, Single Phase L 1 to L2 183 to 229 VAC L1, L2 to ground 1 106to 132VAC C. Using an Enphase Disconnect Tool, disconnectthe AC cable forthe microinverterin question from the Enphase IQ Cable. D. Verifythat utility poweris presentat the microinverterby measuring line to line and lineto ground at the Enphase IQ Cable connector. E. Visually check that the AC branch circuit connections (Enphase IQ Cable and AC connections) are properly seated. Reseat if necessary. Checkalso fordamage, such as rodentdamage. F. Make sure that any upstream AC disconnects, as well as the dedicated circuit breakers for each AC branch circuit, are functioning properlyand are closed. G. Disconnectand re-connectthe DC PV module connectors.The status LED of each microinverterwill Iightsolid green a few seconds afterconnection to DC powerand then blinkgreen six times to indicate normal start-up operation abouttwo minutes after connecting to DC power. The LED subsequently resumes normal operation if the grid is present. See the table on the previous page outlining LED indicators for normal operation. H. Attach an ammeter clamp to one conductorof the DC cables from the PV module to measure microinverter current. This will be under one amp if AC is disconnected. I. Verify the PV module DC voltage is within the allowable range shown in "Specifications" on page 30 of this manual. 24 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation J. Swap DC leads with a known good, adjacent PV module. If after checking Enphase Installer Platform period icaIly(thism aytake up to 30 minutes), the problem moves to the adjacent mod ule,this indicates that the PV module isn'tfunctioning correctly. If it stays in place, the problem iswith the original microinverter. Contact Enphase Customer Supportfor help in reading them icroinverter data and for help in obtaining a replacement microinverter, if needed. K. Check the DC connections between them icroinverter and the PV module. The connection may need to be tightened or reseated. If the connection is worn or damaged, it may need replacement. L. Verify with your utility that line frequency is within range. M. If the problem persists, contact Enphase Customer Support at enphase.com/en-us/support/contact. Disconnecta Microinverter If problems remain afterfollowing the troubleshooting steps listed previously, contact Enphase at enphase.com/en- us/support/contact. If Enphase authorizes a replacement, followthe steps below. To ensure the microinverteris not disconnected from the PV modules under load, follow the disconnection steps in the order shown: A. De -energize the AC branch circuit breaker. B. Enphase AC connectors are tool -removable only. To d isconnectthe m icroinverterfrom the Enphase IQ Cable insert the disconnecttool and remove the connector. C. Cover the PV module with an opaque cover. D. Using a clamp -on meter, verify there is no currentf lowing in the DC wires between the PV module and the microinverter. If current is still flowing, checkthat you have completed steps one and two above. NOTE: Take care when measuring DC currentas most clam p-on meters must be zeroed firstand tend to driftwith time. E. Disconnectthe PV module DC wire connectors from them icroinverter using the Enphase Disconnect Tool. F. If present, loosen and/or remove any bonding hardware. G. Remove the microinverterfrom the PV racking. WARNING: Risk of electric shock. Risk of fire. Do not leave any connectors on the PV system disconnected \ for an extended period. If you do not plan to replace them icroinverter im m ed iately, you must cover any l ) unused connectorwith a sealing cap. Install a Replacement Microinverter A. When the replacement m icroinverter is available, verifythatthe AC branch circuit breaker is de -energized. B. Mount them icroinverter horizontally bracket side up or vertically • Always place them icroinverter under the PV module, protected from direct exposure to rain, sun, and other harmful weather events. Allow am inim um of 1.9 cm (3/4") between the roof and the m icroinverter. Also allow 1.3 cm (1 /2") between the back of the PV module and the top of the microinverter. • For vertical mount, also maintain > 30 cm (12") clearance from the edges of the PV module to protect them icroinverterf rom direct exposure to rain, UV, and other harmful weather events. ,\ WARNING: Risk of equipment damage. Mountthe m icroinverter under the PV m odule. Install the microinverterunder the PV module to avoid direct exposure to rain, UV, and other harmful weather events. • Always install the microinverterbracket side up. 25 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation • Do not mount them icroinverterupside down. • Do not expose the AC or DC connectors (on the En phase IQ Cable connection, PV module, or the micro inverter) to rain or condensation before the connectors are mated. C. Torque the mounting fasteners to the values shown. Do not over torque. • 6 mm (1/4") mounting hardware: 5 N m (45 to 50 in-lbs.) • 8 mm (5/16") mounting hardware:9 N m (80 to 85 in-lbs.) • When using UL 2703 mounting hardware, use the manufacturer's recommended torque value D. If you are using bonding hardware, the old bonding hardware should be discarded, and new bonding hardware must be used when installing the replacement m icroinverter. E. Connect them icroinverterto the IQ Cable connector. Listen fora click as connectors engage. F. Connect the DC leads of each PV module to the DC input connector of them icroinverter. G. Re -mount the PV module above them icroinverter. H. Energize the AC branch circuit breaker and verify operation of the replacement microinverter by checking the Status LED on the connector side of them icroinverter. I. Use the Enphase InstallerApp to delete the old m icroinverter serial numberfromthe Enphase IQ Gateway database. In Enphase Installer App, once connected to the IQ Gateway: a. Tap Micros > Manage. b. Tap the checkbox ■ to the right of them icroi nverter serial numberthat you replaced. c. Tap o to delete them icroinverterfrom the IQ Gateway database. J. Add the new m icroinverter serial number to the Gateway database by initiating a device scan using one of the following methods: a. Method 1: Initiate a scan using the Enphase Installer App • In Enphase InstallerApp, once connected to the IQ Gateway, navigate to the Overview screen. • From the Overview screen, tap Detected > Start Device Scan to start anew 30-minute device scan. • If device scanning on the IQ Gateway is inhibited, the app displays "Scan Inhibited." If you need to add more microinverters to the system when device scanning is inhibited on the IQ Gateway, you must use the Enphase InstallerApp scanning tool to provision them on the IQ Gateway, rather than using the IQ Gateway's device scanning function to discoverthem. If this is not possible and you need to enable device scanning on the IQ Gateway, contact Enphase Customer Supportat enphase.com/en-us/support/contact. b. Method 2: Use an IQ Gateway • Press the Device Scan button on the IQ Gateway. The IQ Gateway begins a 15-minute scan to identify all of them icroinverters deployed atthe site. The MicroinverterCom m unications LED FZ* flashes green during the scan. Microinverter Communications LED Device Scan button K. Login to Enphase Installer Platform to use Enphase Installer Platform'sArray Builder to add the newly detected microinverterto the virtual array. L. Ship the old microinverterto Enphase using the supplied return -shipping label. 26 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation Replacement Parts and Cabling Ordering Replacement Parts Replacement adaptors form icroinverters with MC-4 DC connectors include: • Q-DCC-2: Cable Assembly, DCadaptorto MC-4 These parts are available from your Enphase distributor. Enphase IQ Cable Planning and Ordering The Enphase IQ Cable is a continuous length of 12 AWG, double insulated, outdoor -rated cable with integrated connectors for microinverters.These connectors are preinstalled along the IQ Cable at intervals to accom modate varying PV module widths. The microinverters plug directly into the cable connectors. The cabling is compatible with a variety of PV racking systems. For a list of approved PV racking systems, referto the PV Racking Compatibility documenton the Enphase website at enphase.com/support. Connector Spacing Options IQ Cable is available in three connector spacing options. The gap between connectors on the cable can be 1.3 meters, 2.0 meters, or 2.3 meters. The 1.3 meterspacing is best suited for connecting PV modules installed in portrait orientation, while the 2.0 meter and 2.3 meter spacing allows you to install 60-cell and 72-cell PV modules in landscape orientation, respectively. Cabling Options Ordering options include: Cable Model Connector spacing PV module orientation Connector count per box Q-12-10-240 1.3 m (50") Portrait 240 Q-12-17-240 2.0 m (78") Landscape (60-cell) 240 Q-12-20-200 2.3 m (90") Landscape (72-cell) 200 The cabling system is flexible enough to adaptto almostany solar design. To determine the cable type you need, apply the following considerations: • When mixing PV modules in both portrait and landscape orientation, you may need to transition between cable types. See the preceding table foravailable cable types. • To transition between cable types, install a field wireable connector pair. • In situations where portrait modules are widely spaced, you may need to use landscape spaced cables forthe portrait -oriented PV modules and create loops of excess cable, if needed. !\ WARNING: Do not form loops smallerthan 12cm (4.75") in diameter Enphase IQ Cable Accessories The Enphase IQ Cable is available with several accessory options for ease of installation, including: • Field wireable connectors (male):(Q-CONN-1OM) Make connections from anyfield wireable female connector • Field wireable connectors (female): (Q-CONN-1 OF) Make connections from any IQ Cable open connectoror field wireable male connector • Cable clips: (Q-CLIP-100) Used to fasten cabling to the racking or to secure looped cabling 27 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation • Disconnect tool: (Q-DISC-10) Disconnecttool for IQ Cable connectors, DC connectors, and AC module mount • IQ Cable sealing caps (female): (Q-SEAL-10) One needed to cover each unused connector on the cabling • Terminator: (Q-TERM-1 0) Terminator cap for cut cable ends 28 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQBM / IQBA / IQBH Micro Installation and Operation Technical Data Technical Considerations Be sure to apply the following when installing the En phase IQ8 Series Microinverter System: WARNING: Risk of equipment damage. You must match the DC operating voltage range of the PV 1 module with the allowable inputvoltage range of the En phase Microinverter. -• WARNING: Risk of equipment damage. Them axim um open circuit voltage of the PV module Umust not exceed the specified maximum input voltage of the Enphase Microinverter. PV modules must have conductors labeled "PV Wire" or "PV Cable" to comply with NEC for Ungrounded PV Power Systems. • Verify that the voltage and current specifications of the PV module match those of the microinverter. • The maximum shortcircuitcurrent rating of the PV module mustbe equal to or less than the maximum input DC short circuit current rating of them icroinverter. The output voltage and current of the PV module depend on the quantity, size and temperature of the PV cells, as well as the insolation on each cell. The highest PV module output voltage occurs when the temperature of the cells is the lowest and the PV module is at open circuit (not operating). Bifacial Modules Enphase Microinverters are compatible with bifacial PV modules. Bifacial solar modules produce power from both sides of a bifacial module, increasing total energy generation. The power gained from rear side (bifacial gain) is highly influenced byvarious design factors such as albedo, module elevation, pitch, temperature and shading. The bifacial gain can be anywhere between 0% to 30% of nominal rating (frontside power rating) of the module. Since the bifacial gain is highly influenced by various design considerations, pairing the bifacial module with right m icroinverter depends on the electrical characteristics of a given module. The temperature adjusted electrical parameters (maximum power, voltage and current) of the bifacial modules, considering the front side electrical parameters (i.e. 0% back side gain), must be within the microinverter input parameters range. See Step 3: Mount the Microinverters on page 15 fortips on vertical mounting of bifacial modules. 29 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ /IQ8M /IQ8A / IQ8H Micro Installation and Operation Specifications See specifications in the following tables for: • Enphase IQ8-60-2-US Microinverters • Enphase IQ8PLUS-72-2-US Microinverters • Enphase IQ8M-72-2-US Microinverters • Enphase IQ8A-72-2-US Microinverters • Enphase IQ8H-240-72-2-US Microinverters • Enphase IQ8H-208-72-2-US Microinverters • Enphase IQ Cable IQ8-60-2-US MicroinverterSpecifications Enphase IQ8-60-2-US Microinverter Parameters Topic Unit Min Typical Max DC Parameters Commonlyused modules for pairing' I 235W-350W Peak powertracking voltage I V 27 37 Operating Voltage Range V 16 48 Maximum Input DC Voltage V 50 Minimum/Maximumstartvoltage I V 22 I 48 Max. continuous inputDC current I A I 10 Max. input DC short-circuit current I A I 25 Max. module ISM A � 20 Overvoltage class DC port DC Port backfeed undersingle fault A 0 1x1 ungrounded array; No additional DC side protection PV array configuration required; AC side protection requires max 20A per branch ci rcu it AC Parameters Maximum continuous AC output power VA 240 Peak output power VA 245 Grid -tied powerfactor (adjustable) 0.85 leading 0.85 lagging Nominal ACoutputvoltagerange240VAC (single phase)z Vrms 211 264 Max continuous outputcurrent A 1.0 Nominal frequency Hz 60 Extended frequency range Hz 47 68 Maximum AC outputover current protection device A 20 AC short circuit fault current over 3 cycles Arms 2 High AC voltage trip limitaccuracy Low AC voltage trip limitaccuracy Frequencytrip limitaccuracy % % Hz ±1.0 ±1.0 ±0.1 Trip time accuracy (for trip tim es or delays< 5 sec.) ±ms 33 Trip time accuracy (for trip timesordelays>= 5 sec.) % I 1 Overvoltage class AC port I III AC port backfeed current mA 30 Powerfactor setting I 1.0 30 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQBM / IQBA / IQBH Micro Installation and Operation Enphase IQ8-60-2-US Microinverter Parameters Topic Unit Min Typical I Max Miscellaneous Parameters Maxim um4 m icroinverters per20A (max) AC branch circuit 240 VAC (single phase)3 16 CEC weighted efficiency 240 VAC (single phase) % 97 Total harmonic distortion % <5 Ambienttemperature range oC -40 +60 Night-time power consumption mW 60 Storage temperature range °C -40 +85 Features and Specifications Compatibility Dimensions not including mounting bracket ConnectorType Weight Environmental Category/UV exposure rating Torque specif i cations for fasteners (Do not overtorque) 60-cell/120half-cell PVmodules 212 mm (8.3")x 175mm (6.9")x 30.2 mm (1.2") I Enphase IQTM Connector 1.08 kg (2.381bs) NEMA Type 6 / outdoor • 6 mm (1/4") mounting hardware:5 N m (45 to 50 in-lbs.) • 8 mm (5/16") mounting hardware:9 N m (80 to 85 in-lbs.) When using UL 2703 mounting hardware, use the manufacturer's recommended torque value Cooling Natural convection - No fans Relative Humidityrange 4%to 100%(condensing) Approved for wet locations Yes Pollution degree PD3 Standard Warranty Term http://enphase.com/warranty Compliance Grounding Enphase I08-60-2-US Microinverter Parameters CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE1547:2018 (UL 1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This productis UL Listed as PV Rapid Shutdown Equipment and conformswith NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. The DC circuitmeetsthe requirements for ungrounded PV arrays in NEC. Ground fault protection (GFP) is integrated into the class II double insulated microinverter Monitoring Enphase Installer platform and EnphaseApp monitoring options. Both options require an Enphase IQ Gatewav Communication I Powerline communication (PLC) (1) Pairing PV modules with wattage abovethe limit may result in additional clipping losses. Seethe compatibility calculator at https://Iink.eni3hase.com/module-compatibility (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. 31 © 2022 Enphase Energy Inc. All rights reserved. December2022 IQ8 / IQ8+ / IQBM / IQBA / IQBH Micro Installation and Operation IQ8PLUS-72-2-US MicroinverterSpecifications Enphase IQ8PLUS-72-2-11.11IS Microinverter Parameters Topic Unit Min Typical Max DC Parameters Commonly used modules for pairing' 235W — 440W Peak powertracking voltage V 27 45 Operating Voltage Range V 16 58 Maximum InputDCVoltage V 60 Minimum/Maximumstartvoltage Max. continuous inputDC current V A 22 58 12 Max. input DC short-circuit current A 25 Max. module ISM A 20 Overvoltage class DC port DC Port backfeed undersingle fault PV array configuration II A 0 1 x1 ungrounded array; No additional DC side protection required;AC side protection requires max20A perbranch circuit AC Parameters Maximum continuous AC output power VA Peak output power VA 290 300 Grid -tied powerfactor (adjustable) 0.85 leading 0.85 lagging Nominal AC outputvoltage range 240 VAC (single phase) 2 Vrms 211 264 Max continuous output current Nominal frequency Arms F-F 1.21 Hz F-F 60 Extended frequency range Hz 47 68 Maxim um AC outputover current protection device A 20 AC short circuit fault current over 3 cycles Arms 2 High AC voltage trip limitaccuracy % ±1.0 Low AC voltage trip limitaccuracy % ±1.0 Frequencytrip limitaccuracy Hz ±0.1 Trip time accuracy (for trip times or delays < 5 sec.) ±ms 33 Trip tim e accuracy (for trip tim es or delays — 5 sec.) Overvoltage class AC port AC port backfeed current Power factor setting % 1 III mA 30 1.0 32 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQBM / IQBA / IQBH Micro Installation and Operation Enphase IQ8PLUS-72-2-US Microinverter Parameters Topic IUnit Min Typical Max Miscellaneous Parameters Maxim um4microinverters per20A(max)AC branch circuit 240 VAC (single phase)3 CEC weighted efficiency 240VAC (single phase) Total harmonic distortion Ambienttemperature range Night-time power consumption 13 % 97 I % I I� <5 'C -40 +60 mW 60 Storage temperature range °C -40 +85 Features and Specifications Compatibility 54-cell/108 half -cell, 60-cell/120 half -cell, 66-cell and 72- cell/144 half -cell Dimensions notincluding mounting bracket 212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2") ConnectorType Enphase IQTM Connector Weight I 1.08 kg (2.38lbs) Environmental Category/ UV exposure rating NEMA Type 6 / outdoor • 6 mm (1/4") mounting hardware:5 N m (45 to 50 in-Ibs ) Torque specifications forfasteners 0 8 mm (5/16") mounting hardware:9 N m (80 to 85 in-Ibs.) (Do not overtorque) • When using UL2703 mounting hardware, use the manufacturer's recommended torque value Cooling Natural convection - No fans Relative Humidityrange 4%to 100%(condensing) Approved for wet locations Yes Pollution degree PD3 Standard Warranty Term http://enphase.com/warranty Enphase IQ8PIus-72-2-US Microinverter Parameters Compliance Grounding Monitoring Communication CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE1547:2018 (UL 1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This productis UL Listed as PV Rapid Shutdown Equipment and conformswith NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. The DC circuitmeetsthe requirements for ungrounded PV arrays in NEC. Ground fault protection (GFP) is integrated into the class II double insulated microinverter Enphase Installer Platform and Enphase App monitoring options. Both options require an Enphase IQ Gateway Powerline communication (PLC) (1) Pairing PV modules with wattage above the limit may result in additional clipping losses. Seethe compatibility calculator at htti)s://Iink.eni)hase.com/module-compatibility (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. 33 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation IQ8M-72-2-US Microinverter Specifications Enphase IQ8M-72-2-US Microinverter Parameters Topic I Unit I Min Typical Max DC Parameters Commonlyused modules for pairing' 260W-460W Peak power tracking voltage V 30 45 Operating Voltage Range V 16 58 Maximum InputDCVoltage V 60 Minimum/Maximum start voltage V 22 58 Max. continuous input DC current A 12 Max. input DC short-circuit current A 25 Max. module Ise A 20 Overvoltage class DC port II DC Port backfeed under single fault A 0 PV array configuration 1 x1 ungrounded array; No additional DC side protection required; AC side protection requires max20A perbranch circuit AC Parameters Maximum continuous AC output power VA 325 Peak output power VA 330 Powerfactor (adjustable) 0.85 leading 0.85 lagging Nominal AC outputvoltage range 240 VAC (single phase)2 Vrms 211 264 Max continuous output current Arms 1.35 Nominal frequency Hz 60 Extended frequencyrange Hz 47 68 Maximum AC outputover current protection device A 20 AC short circuit fault current over 3 cycles Arms 2 High AC voltage trip limitaccuracy % ±1.0 Low AC voltagetrip limitaccuracy % ±1.0 Frequencytrip limitaccuracy Hz ±0.1 Trip time accuracy (for trip timesordelays< 5 sec.) ±ms 33 Trip time accuracy (for trip tim es or delays >= 5 sec.) % 1 Overvoltage class AC port III AC port backfeed current mA 30 Powerfactor setting 1.0 34 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQBM / IQBA / IQBH Micro Installation and Operation Enphase IQ8M-72-2-US Microinverter Parameters Topic IUnit Min Typical Max Miscellaneous Parameters Maxim um4microinverters per20A(max)AC branch circuit 240 VAC (single phase)3 CEC weighted efficiency 240VAC (single phase) Total harmonic distortion Ambienttemperature range Night-time power consumption 11 % 97.5 I % I I� <5 'C -40 +60 mW 60 Storage temperature range °C -40 +85 Features and Specifications Compatibility 54-cell/108 half -cell, 60-cell/120 half -cell, 66-cell and 72- cell/144 half -cell Dimensions notincluding mounting bracket 212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2") ConnectorType Enphase IQTM Connector Weight I 1.08 kg (2.38lbs) Environmental Category/ UV exposure rating NEMA Type 6 / outdoor • 6 mm (1/4") mounting hardware:5 N m (45 to 50 in-Ibs ) Torque specifications forfasteners 0 8 mm (5/16") mounting hardware:9 N m (80 to 85 in-Ibs.) (Do not overtorque) • When using UL2703 mounting hardware, use the manufacturer's recommended torque value Cooling Natural convection - No fans Relative Humidityrange 4%to 100%(condensing) Approved for wet locations Yes Pollution degree PD3 Standard Warranty Term http://enphase.com/warranty Enphase IQ8M-72-2-US Microinverter Parameters Compliance Grounding Monitoring Communication CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE1547:2018 (UL 1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This productis UL Listed as PV Rapid Shutdown Equipment and conformswith NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. The DC circuitmeetsthe requirements for ungrounded PV arrays in NEC. Ground fault protection (GFP) is integrated into the class II double insulated microinverter Enphase InstallerApp and Enphase App monitoring options. Both options require an Enphase IQ Gateway _ Powerline communication (PLC) (1) Pairing PV modules with wattage above the limit may result in additional clipping losses. Seethe compatibility calculator at htti)s://Iink.eni)hase.com/module-compatibility (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. 35 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation IQ8A-72-2-US M icroinverter Specifications Topic Enphase IQ8A-72-2-US Microinverter Parameters DC Parameters Unit Min I Typical I Max Commonlyused modules for pairing' 295W — 50OW Peak powertracking voltage V 32 45 Operating Voltage Range V 16 58 Maximum InputDCVoltage V 60 Max. continuous input DC current A 12 Max. input DC short-circuit current A 25 Max. module ISM A 20 Overvoltage class DC port II DC Port backfeed under single fault A 0 PV array configuration 1 x1 ungrounded array; No additional DC side protection required;AC side protection requires max20A perbranch circuit AC Parameters Maximum continuous AC output power VA 349 Peak output power VA 366 Powerfactor (adjustable) 0.85 leading 0.85 lagging Nominal AC outputvoltage range 240 VAC (single phase) 3 Vrms 211 264 Max continuous output current Arms 1.45 Nominal frequency Hz 60 Extended frequency range Hz 47 68 Maximum AC outputover current protection device A 20 AC short circuit fau It current over 3 cycles Arms for over 3 cycle 5.8Arm s H ig h AC voltage tri p I i m it accu racy % ±1.0 Low AC voltagetrip limitaccuracy % ±1.0 Frequencytrip limitaccuracy Hz ±0.1 Trip time accuracy (for trip tim es or delays < 5 sec.) ±ms 33 Trip time accuracy (for trip tim es or delays >= 5 sec.) % 1 Overvoltage class AC port III AC port backfeed current mA 30 Powerfactor setting 1.0 36 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQBM / IQBA / IQBH Micro Installation and Operation Enphase IQ8A-72-2-US Microinverter Parameters Maxim u m4 m icroinverters per 20A (m ax) AC branch circuit 240 VAC (single phase) 11 CEC weighted efficiency 240 VAC (single phase) I % I I 97 Total harmonic distortion % <5 Am bienttem perature range oC -40 +60 Night-time power consumption mW 60 Storage temperature range °C -40 +85 Features and Specifications Compatibility 54-cell/108 half -cell, 60-cell/120 half -cell, 66-cell and 72- cell/144 half -cell Dimensions notincluding mounting bracket 212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2") ConnectorType Enphase IQTM Connector Weight 1.08 kg (2.38lbs) Environmental Category/ UV exposure rating NEMA Type 6 / outdoor Torque specifications for fasteners (Do not over torque) Cooling • 6 mm (1/4") mounting hardware:5 N m (45 to 50 in-lbs.) 8 mm (5/16") mounting hardware:9 N m (80 to 85 in-lbs.) • When using UL2703 mounting hardware, use the manufacturer's recommended torque value I Natural convection - No fans Relative Humidityrange 4%to 100%(condensing) Approved for wet locations Yes Pollution degree PD3 Standard Warranty Term htti)://enr)hase.com/warranty Enphase IQ8A-72-2-US Microinverter Parameters CA Rule 21 (UL 1741-SA), UL62109-1, IEEE1547:2018 (UL1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 Compliance This productis UL Listed as PV Rapid Shutdown Equipment and conformswith NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. The DC circuitmeetsthe requirements for ungrounded PV Grounding arrays in NEC. Ground faultprotection (GFP) is integrated into the class II double insulated microinverter Monitoring Enphase Installer Platform and EnphaseApp monitoring options. Both options require an Enphase IQ Gateway Communication Powerline communication (PLC) (1) Pairing PV modules with wattage above the limit may result in additional clipping losses. Seethe compatibility calculator at https://Iink.enphase.com/module-compatibility (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. 37 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation IQ8H-240-72-2-US Microinverter Specifications Enphase IQ8H-240-72-2-US Microinverter Parameters Topic M MA6. DC Parameters Unit I Min I Typical I Max Commonlyused modules for pairing' 320W — 540W Peak power tracking voltage V 36 45 Operating Voltage Range V 16 58 Maximum InputDCVoltage V 60 Minimum/Maximum start voltage V 22 58 Max. continuous input DC current A 12 Max. input DC short-circuit current A 25 Max. module Ise A 20 Overvoltage class DC port DC Port backfeed undersingle fault PV array configuration II A 0 1 x1 ungrounded array; No additional DC side protection required; AC side protection requires max20A per branch circuit AC Parameters Maximum continuous AC output power VA 380 Peak output power VA 384 Powerfactor (adjustable) 0.85 leading 0.85 lagging Nominal AC output voltage range 2240 VAC (single phase) Vrms 211 264 Max continuous output current Arms 1.58 Nominal frequency Hz 60 Extended frequency range Hz 47 68 Maximum AC output over current protection device A 20 AC short circuit fault current over 3 cycles Arms 2 High ACvoltagetriplimitaccuracy % ±1.0 Low AC voltagetrip limitaccuracy % ±1.0 Frequencytrip limitaccuracy Hz ±0.1 Trip time accuracy (for trip tim es or delays < 5 sec.) ±ms 33 Trip time accuracy (for trip timesor delays>= 5 sec.) % 1 Overvoltage class AC port III AC port backfeed current mA 30 Powerfactor setting 1.0 38 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQBM / IQBA / IQBH Micro Installation and Operation Enphase IQ8H-240-72-2-US Microinverter Parameters Topic IUnit Min Typical Max Miscellaneous Parameters Maxim um4microinverters per20A(max)AC branch circuit 240 VAC (single phase) 10 CEC weighted efficiency 240VAC (single phase) Total harmonic distortion Ambienttemperature range Night-time power consumption % 97 I % I I� <5 'C -40 +60 mW 60 Storage temperature range °C -40 +85 Features and Specifications Compatibility 54-cell/108 half -cell, 60-cell/120 half -cell, 66-cell and 72- cell/144 half -cell Dimensions notincluding mounting bracket 212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2") ConnectorType Enphase IQTM Connector Weight I 1.08 kg (2.38lbs) Environmental Category/ UV exposure rating NEMA Type 6 / outdoor • 6 mm (1/4") mounting hardware:5 N m (45 to 50 in-Ibs ) Torque specifications forfasteners 8 mm (5/16") mounting hardware:9 N m (80 to 85 in-Ibs.) (Do not overtorque) • When using UL2703 mounting hardware, use the manufacturer's recommended torque value Cooling Natural convection - No fans 4%to 100%(condensing) Relative Humidityrange Approved for wet locations Yes Pollution degree PD3 Standard Warranty Term http://enphase.com/warranty Enphase IQ8H-240-72-2-US Microinverter Parameters CA Rule 21 (UL 1741-SA), UL62109-1, IEEE1547:2018 (UL1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 Compliance This productis UL Listed as PV Rapid Shutdown Equipment and conformswith NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. The DC circuitmeetsthe requirements for ungrounded PV Grounding arrays in NEC. Ground fault protection (GFP) is integrated into the class II double insulated microinverter Monitoring Enphase Installer Platform and Enphase App monitoring options. Both options require an Enphase IQ Gateway Powerline communication (PLC) Communication (1) Pairing PV modules with wattage above the limit may result in additional clipping losses. Seethe compatibility calculator at htti)s://Iink.eni)hase.com/module-compatibility (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. 39 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation IQ8H-208-72-2-US MicroinverterSpecifications Enphase IQ8H-208-72-2-US Microinverter Parameters Topic Unit Min Typical Max DC Parameters Commonly used modules for pairings 295W — 500W Peak powertracking voltage V 36 45 Operating Voltage Range V 16 58 Maximum Input DC Voltage V 60 Minimum/Maximum startvoltage V 22 58 Max. continuous inputDC current A 12 Max. input DC short-circuit current A 25 Max. module Ise A 20 Overvoltage class DC port II DC Port backfeed undersingle fault A 0 1 x1 unarounded arrav: No additional DC side protection PV array configuration required;AC side protection requires max20A perbranch circuit AC Parameters Maximum continuous AC output power VA 360 366 Peak output power VA Powerfactor (adjustable) 0.85 leading 0.85 lagging 183 229 Nominal AC outputvoltage range3208 VAC Vrms Max continuous outputcurrent Arms 1.73 Nominal frequency Hz 60 Extended frequency range _ Maximum ACoutputover current protection device AC short circuit fault current over 3 cycles H ig h AC voltag e tri p I i m it accu racy Hz A Arms 47 68 20 4.4 % ±1.0 Low AC voltage trip limitaccuracy % ±1.0 Frequencytrip limitaccuracy Hz ±0.1 Trip time accuracy (for trip ti m es or delays < 5 sec.) ±m s 33 Trip time accuracy (for trip timesordelays>= 5 sec.) % 1 Overvoltage class AC port III AC port backfeed current mA 30 Powerfactor setting 1.0 40 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQBM / IQBA / IQBH Micro Installation and Operation Enphase IQ8H-208-72-2-US Microinverter Parameters Topic IUnit Min Typical Max Miscellaneous Parameters Maxim um4microinverters per20A(max)AC branch circuit 208 VAC 9 CEC weighted efficiency208 VAC Total harmonic distortion % 97 I % I I� <5 Ambienttemperature range 'C -40 +60 Night-time power consumption mW 60 Storage temperature range °C -40 +85 Features and Specifications Compatibility 54-cell/108 half -cell, 60-cell/120 half -cell, 66-cell and 72- cell/144 half -cell Dimensions notincluding mounting bracket 212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2") ConnectorType Enphase IQTM Connector Weight I 1.08 kg (2.38lbs) Environmental Category/ UV exposure rating NEMA Type 6 / outdoor • 6 mm (1/4") mounting hardware:5 N m (45 to 50 in-Ibs ) Torque specifications forfasteners 8 mm (5/16") mounting hardware:9 N m (80 to 85 in-Ibs.) (Do not overtorque) • When using UL2703 mounting hardware, use the manufacturer's recommended torque value Cooling Natural convection - No fans Relative Humidityrange 4%to 100%(condensing) Approved for wet locations Yes Pollution degree PD3 Standard Warranty Term http://enphase.com/warranty Enphase IQ8H-208-72-2-US Microinverter Parameters CA Rule 21 (UL 1741-SA), UL62109-1,IEEE1547:2018 (UL 1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 Compliance This productis UL Listed as PV Rapid Shutdown Equipment and conformswith NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. The DC circuitmeetsthe requirements for ungrounded PV Grounding arrays in NEC. Ground fault protection (GFP) is integrated into the class II double insulated microinverter Monitoring Enphase Installer Platform and Enphase App monitoring options. Both options require an Enphase IQ Gateway Powerline communication (PLC) Communication (1) Pairing PV modules with wattage above the limit may result in additional clipping losses. Seethe compatibility calculator at htti)s://Iink.eni)hase.com/module-compatibility (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. (5) The IQ8H-208 variant will be operating in grid -tied mode only at 208VAC 41 © 2022 Enphase Energy Inc. Al rights reserved. December2022 IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation IQ Cable Specifications Specification Value 600V Voltage Rating Voltage withstand test (kV/1 min) AC 3.0 Max DC conductor resistance (20°C) (0/km) 5.433 Insulation resistance (20°C) >_20M (Q/Km) System temperature range (ambient) -400C to +65°C (-40°F to 149°F) Cable temperature rating 90°C Dry / 900C Wet Cable rating DG Certification UL3003, TC-ER equivalent Flame test rating FT4 Cable conductor insulatorrating THHN/THWN-2 Environmental protection rating IEC 60529 IP67NEMA 6 UV resistance 720h Compliance RoHS, OIL RES I, CE, UV Resistant, combined ULfor Canada, and United States Conductorsize 12 AWG Maximum loop size 12 cm (4.75 ") Flat cable dimensions Sealing cap dimensions Cable con nectordimensions 6 mm x 9.5 mm (0.2"x 0.37") 38.6 mm x20 mm (1.5"x 0.7") 20 mm x1.1 mm x6.5 mm (0.7"x 0.04"x 0.25") Enphase Connector Ratings Enphase Connectors on the cable assemblies in the following table have a maximum current of 20 A, a maximum OCPD of 20 A, and maximum ambient temperature of -40' to +79' C (40° to +174.2° F) and are rated for disconnection under load Part Number Model Maximum Voltage 840-00387 Q-12-10-240 277VAC 840-00388 Q-12-17-240 277VAC 840-00389 Q-12-20-200 277VAC 840-00385 Q-DCC-2 100VDC 840-00386 Q-DCC-5 100VDC 42 © 2022 Enphase Energy Inc. Al rights reserved. December2022 O N 0 N N m 3 En CD s ccEr m 0 m 0 (D m N 0 N N M 9 To Sheet / A la hoja de: t Panel Group/Grupo de los paneles: Azimuth/Azimut: Tilt/Inclinaci6n: Sheet/Hoja of/de Customer/Cliente: Installer/Instalador: N S E W N S E O 4— 1 2 3 4 5 6 7 A B C D E F G H J K L M Scan completed map and upload it to Enphase. Click "Add a New System" Envoy Serial Number Label / at https://enlighten.enphaseenergy.com. Use this map to build the virtual array in Enlighten's Array Builder. / Ntimero de serie de Envoy � E N P H AS E Escanee el mapa completo y cirguelo en Enphase. Haga clic en "Anadir nuevo sistema" en https://enlighten.enphaseenergy.com. Utilice este mapa para crear el conjunto de paneles virtual en el Creador de conjuntos de paneles de Enlighten. To Sheet / A la hoja de: 0 a W U) 9 M M N O 00 .0 w 00 rJ D p 00 0' 0 v v O 73 N 73 Q O m N O 7 A A 0 m 0 rD 3 s m N O N N D IQ CABLE BLACK - L1 NOTE: Ground PV modules according to local RED - L2 JUNCTION METER IU I --- —a — — � ..� TERMINATOR CAP C TO O INSTALLED ON END METER OF CABLE OR AC DISTRIBUTION NOTE: The IQ8 Micro, the IQ8+ Micro, the IQ8M Micro, the IQ8A Micro, and the IQ8H Micro have integrated PANEL nr nd nri riniiNa inaulatim m nQFC nr Fr r. is r—iirarl Tha nr. nircuit is isnlatnrl and incnlntxt frnm ground and meets the requirements of NEC IQ GATEWAY UP TO 16 I08 MICROS, 13 IQ8+ MICROS, 11 IQ8M MICROS, 11 IQBA 8 MICROS, or 10 IQ8H MICROS PER 240 AC BRANCH CIRCUIT ONE 2-POLE 20 AM I UP TO 9 IQ8H MICROS PER 208 VAC BRANCH CIRCUIT CIRCUIT BREAKER PER BRANCH m CIRCUIT N EUTR& GROU D �jftteejEL OR SUBPPNEL IMPORTANT: Make sure to measure the line -to -line and the line -to -neutral voltage of all service entrance conductors prior to installing any solar equipment. The voltages for the microinverters should be within the following ranges: - 240 VAC: line to line: 211 to 264 VAC, line to ground: 106 to 132 VAC. - 208 VAC: line to line: 183 to 229 VAC, line to ground: 106 to 132 VAC. ENPHASE I08, IQ8+, IQ8M, IQ8A, and IQ8H MICROINVERTER FIELD WIRING DIAGRAM 02021 Enphase Energy Inc. All rights Cn W 3 �5 _G v cc 3 p Co p Co fJ co p Co D p Co I C7 O 7 fn v y 0 Sv Q O CD O 7