Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD2023-1082+Manufacturer_Specifications_and_Installation_Instructions+8.30.2023_9.01.04_AM+3754911
Submittal Single Packaged Gas Heating / Electric Cooling 4YCC403OE1070A Note: "Graphics in this document are for representation only. Actual model may differ in appearance. " October 2022 4YCC4030E-SUB-1 A -EN Product Specifications MODEL 4YCC403OE1070A RATED Volts/PH/Hz 208-230/1/60 Performance Cooling BTUH (a) 28000 Indoor Airflow (CFM) 880 Power Input (KW) 2.21 EER2/SEER2 (BTU/Watt-Hr.) 11.00 / 13.40 Sound Power Rating [dB(A)] (b) 70.0 PERFORMANCE HEATING() Input BTUH-1st Stage (Natural Gas) (d) 70000 AFUE 81 Temp. Rise — Min/Max (OF) 30 / 60 Orifice Qty/Drill Sz. (Natural Gas) 2 / #33 POWER CONN. — V/Ph/Hz 208-230/1/60 Min. Breh. Cir. Ampaeity (e) 20.8 Fuse Size — Max. (amps) 30 Fuse Size — Recmd. (amps) 30 COMPRESSOR SCROLL VOLTS/PH/HZ 208-230/1/60 R.L. Amps — L.R. Amps 12.8 / 67.8 OUTDOOR COIL — TYPE SPINE -FIN Rows/F.RI 2 / 24 Face Area (sq. ft.) 13.32 Tube Size (in.) 3/8 INDOOR COIL — TYPE MCHE Rows/F.RI 2 / 16 Face Area (sq. ft.) 2.7 Tube Size Width (in.) 0.81 Refrigeration Control EXPANSION VALVE Drain Conn. Size (in.) 3/4 FEMALE NPT OUTDOOR FAN — TYPE SWEPT DIA.(IN.) 23.4 DRIVE/NO. SPEEDS DIRECT/ 1 CFM @ 0.0 in. w.g. (f) 2800 Motor — HP/R.P.M 1/6/ 825 Volts/Ph/Hz 208-230/1/60 F.L. Amps/L.R Amps 0.85 / 1.65 MODEL 4YCC403OE1070A INDOOR FAN — TYPE CONSTANTTORQUE ECM Dia. x Width (in.) 10.62 X 10.62 Drive/No. Speeds DIRECT / 4 CFM @ 0.0 in. w.g. (9) SEE FAN PERF TABLE Motor — HP/R.RM. 1/2 / 1050 Volts/Ph/Hz 208-230/1/60 F.L. Amps 4.1 COMBUSTION FAN —TYPE CENTRIFUGAL Drive/No. Speeds DIRECT/ 1 Motor — H P/R. R M. 1/34 / 3290 Volts/Ph/Hz 230/1/60 FLA 0.20 FILTER / FURNISHED NO Type Recommended THROWAWAY Recmd. Face Area (sq. ft) (h) 4.0 REFRIGERANT R-410A Charge (lbs.) 7.38 CHARGING SPECIFICATIONS Subcooling 8o GAS PIPE SIZE (in.) 1/2 DIMENSIONS H X D X W Crated (in.) 48 X 45 X 52 WEIGHT Shipping (lbs.) / Net (lbs.) 451 / 377 (a) Rated in accordance with AHRI Standard 210/240. AHRI standard rating conditions are: 80 D.B.67 W.B. entering air to indoor coil. 95 D. B. entering air to outdoor coil. (b) Sound Power values are not adjusted for AHRI 270-95 tonal corrections. M Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. (d) Convertible to LPG. (e) This value is approximate. For more precise value, see Unit Nameplate. (f) Standard Air — Dry Coil — Outdoor. W Based on U.S. Government Standard Tests. (h) Filters must be installed in return air stream. Square footages listed are based on 300 f. p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 4YCC4030E-SUB-1 A -EN Outline Drawings Figure 1. 2 - 5 Ton Models In T I.Ts 111/16] SECTION X-X TYPICAL (8) SIDES OF SIDEFLOW DUCT OPENINGS 18.03 18.29 [23/32] 1/.22 SECTION Y-Y TYPICAL (8) SIDES OF DOWNFLOW DUCT OPENINGS s LEFT SIDE 2 - 3 TON Units 1 3.5 - 5 TON Units RECOMMENDED SERVICE CLEARANCE mm Inches W/ ECONOMIZE W/ ECONOMIZE BACK SIDE 305 12 762 [301 305 [121 762 30 LEFTSIDE 762 [30] 914 36 914 [36] 1067 421 RIGHTSIDE 610 24 610 24 FRONTSIDE 1067[421 762 [30] 4 OUTLET FRONT SIDE BOTTOM SIDE Note: The view labeled "Bottom side" represents the base as viewed looking up from underneath the unit. 4YCC4030E-SUB-1 A -EN Outline Drawings Figure 2. 2 - 5 Ton Models 2 E BOTTOM DUCT OPENINGS BACK DUCT OPENINGS WE 1 POWER ENTAY 34.13 DIA. HOLE [I-3/32] 84.96 [S-I I/32] AS LINE ENTRY FOR 12. TO " 23 N.P.T. 98.66 OAS CONNECTION 3 T 8 12T.84 I-RIGHT SIDE [5-I/32] BACK SIDE PHYSICAL DIMENSIONS mm[In] HEIGHT -A ..[Inch] B C D E F G H I J K L M N 4YCC4024 898.53 35-3/8 304.80 [12] 75.41 [2.93] 75.41 [2.93] 406.40 [16] 167.89 [6.61] 173.46 [6-27/32] 304.80 [12] 79.50 [3.13] 398.22 [15.68] 176.07 [6.93] 177.55 [6.99] 296.62 [11.68] 1155.45 [45.49] 4YCC4030 949.33 [37-3/8] 4YCC4036 4YCC4042 898.53 [35-3/81 457.20 [18] 75.41 [2.97] 75.41 [2.97] 381.00 [15] 244.09 [9.61] 318.75 [12.55] 381.00 [15] 79.50 [3.13] 449.02 [17.68] 176.07 [6.93] 322.84 [12.71] 372.82 [14.68] 1402.34 4YCC4048 1000.13 [35-3/8] 4YCC4066 Corner Weights KG/LBS SHIPPING WEIGHT KG/LBS UNIT WEIGHT KG/LBS Center Of Gravity mm[inch] W1 W2 W3 W4 BB CC 4YCC4024' 060 58 129 37 811 26 [581 41 [901 196 F 321 162 [3581 480 [191 528 21 4YCC4030* 070 61 [135] 39 [85] 28 [61] 43 [95] 205 [451] 171 [377] 407 [16] 594 [23] 4YCC4036* 070 61 [134] 39 [84] 28 60 43 [95] 205 4381 171 [3741 407 161 594 28] 4YCC4036* 090 61 136 39 86 28 [61] 43 [96] 205 [453] 171 [379] 407 [16] 594 [28] 4YCC4042*060 71 157 47 103 35 [761 53 1171 1 252 r555 1 202 [2021 1 470 [191 731 29 4YCC4042*090 72 158 47 104 35 [781 1 54 [1181 1 255 [5611 1 207 [2021 1 470 [191 731 29 4YCC4048*070 71 157 45 98 33 73 54 119 250 552 202 448 433 1 743 29 4YCC4048*090 72 159 45 99 34 75 55 120 253 557 205 453 433 1 743 29 4YCC4060*090 77 170 46 101 35 76 58 128 263 580 216 476 433 1 743 29 4YCC4060*115 78 172 46 102 35 7 59 130 266 586 219 482 414 16 635 25 4YCC4030E-SUB-1 A -EN Indoor Fan Performance Table 1. Airflow Tables — 2.5 Tons 4YCC403OE1070 EXTERNAL STATIC PRESSURE (IN.WG) Horizontal Airflow [Down Airflow] Motor Speed 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 i Constant CFM Circulation APPROXIMATELY 40-50% COOLING OR HEATING AIRFLOW WATTS 1051 994 939 889 840 CFM Cooling - Low (1041) (984) (930) (880) (831) WATTS 126 134 142 150 158 (126) (135) (143) (150) (158) CFM - - 1108 1070 1027 975 920 875 Cooling- Med (1097) (1059) (1017) (965) (911) (866) WATTS 239 247 256 267 274 282 - (240) (248) (258) (269) (276) (284) CFM _ - _ 1099 1059 1017 968 Cooling - High (1088) (1048) (1007) (959) WATTS - _ - 259 268 278 289 (260) (270) (279) (290) CFM 1148 1103 1061 1022 982 932 Heating - Low (1136) (1091) (1050) (1012) (972) (922) 199 208 216 224 233 243 WATTS (197) (205) (214) (222) (230) (241) CFM - _ - 1158 1122 1084 1039 988 Heating -High (1147) (1111) (1073) (1028) (978) 301 310 320 331 343 WATTS - - (298) (307) (317) (328) (339) - - Note: Cooling airflow must not exceed 1125 CFM due to condensate blowoff. To set indoor motor for the desired speed options, connect the motor leads in the taps as shown below: Table 2. Motor Wiring: 4YCC4024 - 42, 4YCC4060 MOTOR WIRING MOTORTAP MODE/SPEED 1 2 3 4 5 CONSTANT CIRCULATION G(GR) COOLING -LOW & HEATING -LOW G (GR) Y (YL) W (PR) COOLING -LOW & HEATING -HIGH G (GR) Y (YL) W (PR) COOLING-MED & HEATING -LOW G (GR) Y (YL) W (PR) COOLING-MED & HEATING -HIGH G (GR) Y (YL) W (PR) COOLING -HIGH & HEATING -LOW G (GR) W (PR) Y (YL) COOLING -HIGH & HEATING -HIGH G (GR) Y (YL) W (PR) G signal (GR- green wire), Ysignal (YL- yellow wire), W signal (PR- purple wire) 4YCC4030E-SUB-1 A -EN Full Perimeter Roof Mounting Curb 0 CHANNELEND Figure 3. 2.0 — 3.0 Ton Models BAYCURB050A Full Perimeter Roof Mounting Curb 38 i - 3 5/8 3/ 16 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. / CHANNEL SIDE wnn) NATI FR HOLE IN; ROOF 43 3/8 35 7/8 / SERVICE CLEARANCE DIMENSIONS A B C D WC*/TC* 42.00 36.00 12.00** 24.00 DC*/YC* 42.00 36.00 12.00** 36.00 ** 42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY 6 4YCC4030E-SUB-1 A -EN Optional Equipment — Filter Rack Figure 4. BAYFLTR101 Filter Rack (2.0 - 3.0 Ton Models) BAYFLTR201 (3.5 - 5.0 Ton Models) (Mounts in Filter/Coil Section) Figure 5. BAYACCD0R1A Hinged Filter Access Door (2.0 - 3.0 Ton Models) BAYACCD0132A (3.5 - 5.0 Ton Models) Replaces Filter/Coil Access Panel Note: The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4YCC4030E-SUB-1 A-E N Optional Equipment — Economizer Table 3. BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC Unit Economizer Unit Application Models Economizer eeeeeeeeee.�` rain hood eeeeeeaeeeeE e e e e e e BAYECON101A 2.0 — 3.0 Ton Models Outside air dampers Return air dampers Required c filter kit, order Mist separately eliminator BAYECON 102A 3.5 — 5.0 Ton Models Return Relief damper Duct Roofcurb Table 4. BAYCON200, 201A Horizontal Economizer and Rain Hood Economizer A B F\ Q C Gaskets (2) Duct E �— Rain Hood Mixed Air Sensor Economizer Models A B C D E F BAYECON200A 2.0 — 3.0 Ton 22" 20" 16-7/8" 15-11/16" 11-11/16" 15" BAYECON201A 3.5 — 5.0 Ton 26" 22-21/32" 19" 17-11/16" 14-11/16" 21-3/8" Note: The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4YCC4030E-SUB-1 A-E N Optional Equipment — Outside Air Damper Table 5. BAYOSAH001 and 002A Outside Air Damper (Replaces Filter/Coil Access Panel A r, FULLY OPEN Manual Fresh Air Model Unit Application Models A B C D BAYOSAHOOlA 2.0 — 3.0 Ton 22-7/16" 20-11/16" 12-3/8" 9-3/16" �0 B FULLY CLOSED BAYOSAH002A 3.5 — 5.0 Ton 25-3/16" 20-11/16" 12-3/8" 9-3/16" Table 6. BAYDMPR101 and 102A, 25% Motorized Outside Air Damper (Mounts Over Horizontal Return Air Opening) A r, Manual Fresh Air Model Unit Application Models A B C D E BAYDM- PR101A 2.0 — 3.0 Ton 15-13/16" 11-13/16" 10-1/4" 11-1/2" 12-1/4" C S /� E BAYDM- 3.5 — 5.0 18-3/16" 15-1/8" 10-1/4" 11-1/2" 12-1/4" PR102A Ton Note; The drawings on this page are prepared by the manufacturerin order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4YCC4030E-SUB-1 A-E N Mechanical Specifications General The units shall be horizontal airflow as shipped and convertible to downflow. All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. Units shall be certified to UL Standard 1995. Units shall be designed to operate at ambient temperatures as high as 1151F. Cooling performance shall be rated in accordance with AHRI standards. The YC heating/cooling unit design is certified to ANSI 221.47/CSA 2.3, specifically for outdoor applications using natural gas or propane. All units shall be designed for outdoor rooftop or ground level installation. Unit Casing All components shall be mounted in a weather - resistant steel cabinet with an enamel finish. Access panels shall be provided for unit controls and indoor coil and fans. Indoor air section compartment shall be completely insulated with fireproof, permanent, odorless fiber material. Knockouts shall be provided for utility and control connections. Drain connections shall be provided to accommodate indoor water runoff. Compressor The compressor shall be hermetically sealed, high efficiency scroll compressors. Internal overcurrent and over temperature protection, internal pressure relief shall be standard. Other features include centrifugal oil pump, low vibration and noise. Refrigeration System All units shall have refrigerant control. Service pressure tap ports and a refrigerant line filter shall be standard. Evaporator Coil (2-4 Ton Models) All aluminum micro channel, extruded tubes, mechanically bonded to aluminum fins, and factory pressure and leak tested at 480 —650 psig. All units have TXV to control refrigerant flow. Condenser Coil The Spine Fin TM condenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is 3/8" OD seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2.000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan Constant Torgue, forward -curved, centrifugal wheel in a Composite Vortica ® Blower housing. Motor shall have thermal overload protection and permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts. Outdoor Fan One direct -drive, statically and dynamically balanced propeller fan shall be used in a draw -through vertical discharge configuration. Permanently lubricated weather proof motor shall have built-in thermal overload protection. System Controls System controls include condenser fan, evaporator fan and compressor contactors. Accessories Roof Curb The roof curb shall be designed to mate with the unit and provide support and complete weathertight installation when properly installed. Adhesive back polyurethane sealing strips shall be provided to ensure an airtight seal between supply and return openings of the curb and unit. The roof curb design allows field fabricated ductwork to be connected directly to the curb. Curb ships knocked down for field assembly, and includes factory installed wood nailer strips. Heating System Gas -Fired Heating Section Models shall provide completely assembled, wired and piped gas fired heating systems within unit. Design certified by UL, specifically for outdoor application. Threaded gas connection on the unit. Electric Ignition System Main burner is lit each time thermostat calls for heat. Flame sensor proves flame and keeps the main burner on. Should a loss of flame occur, the main valve closes and the spark recurs within 0.8 seconds. When thermostat is satisfied, main burner is extinquished. Forced Combustion Blower Insures flame stability under varying wind conditions. Gives higher combustion efficiency and location flexibility. Heat Exchanger Stainless steel tubes. Free floating design. Burners Stainless steel. Multi -port inshot. 10 4YCC4030E-SUB-1 A-E N Mechanical Specifications Single Source Power Entry This accessory when used with electric heat accessory shall allow single source power connection to unit and heater combination. Single source power entry kits shall have specific matching heater(s). Kit shall include high voltage terminal blocks, fuse blocks and fuses, cut -to -length interconnecting wiring, and junction box (if required) to provide power sources with fuse protection as required for both the unit and accessory heater. Kit components shall install within the heater cabinet in the heater access section. Single source branch power circuit shall be protected and wired in accordance with local codes. Fully Modulating Economizer This accessory shall be field installed and be composed of the following items: 0-100 % fresh air damper, damper drive motor, fixed dry bulb enthalpy control, and low voltage pigtails for electrical connections. Solid state enthalpy or differential enthalpy control is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometric relief damper shall be standard with the economizer and provide a pressure operated damper that shall be gravity closing and prohibit entrance of outside air on equipment "off" cycle. Economizer requires BAYRLAY004A relay kit to interface the economizer to the heat pump. Manual Outside Air Dampers Rain hood and screen shall be field installed. Suitable for up to 25% outside air. Start Kit Extra compressor starting capacity for single phase equipment. Control Options Standard Indoor Thermostats Two stage heating/cooling or one stage heating/ cooling thermostats shall be available in either manual or automatic changeover. Programmable Electronic Night Setting Thermostat Programmable electronic thermostat shall provide heating setback and cooling setup with 7—day programming capability. 1H/1C or 21-1/2C models available. 4YCC4030E-SUB-1 A-E N 11 About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com. 0%-us Intertek The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 4YCC4030E-SUB-1A-EN 28Oc12022 Supersedes (New) ©2022