Loading...
BLD2024-0243_Manufacturer_Specifications_and_Installation_Instructions_2.20.2024_11.26.45_AM_4069888MITSUBISHI /_ ELECTRIC Changes for the Better Job Name: M-SERIES Location: I Date: Purchaser: Engineer: Submitted to: For ❑Reference ❑Approval ❑Construction System Designation: Schedule No.: GENERAL FEATURES • Quiet operation II _ • Built-in base pan heater to prevent ice in drain pan Ilu Ag ACCESSORIES I�p Three -port Branch Box (PAC-MKA32BC) III Five -port Branch Box (PAC-MKA52BC) Distribution Pipe for Flare Connection III — (MSDD-50AR; necessary for installing two branch boxes) El Distribution Distribution Pipe for Brazed Connection IIII — (MSDD-50BR; necessary for installing two branch boxes) 3/8" x 1/2" Port Adapter (MAC-A454JP) IIII 1/2" x 3/8" Port Adapter (MAC-A455JP) 1/2" x 5/8" Port Adapter (MAC-A456JP) 1/4" x 3/8" Port Adapter (PAC-493P1) 3/8" x 5/8" Port Adapter (PAC-SG76RJ) Windscreens (*1) Specifications Model Name Unit Type MXZ-4C36NAHZ Cooling* Non -ducted / Ducted Rated Capacity Btu/h 36,000 / 36,000 Rated Total Input W 2,570 / 2,880 Heating at 47°F* (8.3°C*) Non -ducted / Ducted Rated Capacity Btu/h 45,000 / 45,000 Rated Total Input W 3,340 / 3,560 Heating at 17°F* (-8.3°C*) Non -ducted / Ducted Maximum Capacity Btu/h 45,000 / 45,000 Heating at 5*F* (-15*C*) Maximum Capacity Btu/h 45,000 Electrical Requirements Power Supply Voltage, Phase, Hertz 208 / 23OV, 1-Phase, 60 Hz Max. Breaker Size / Max. Fuse Size A 45 / 50 MCA A 42 Voltage Indoor - Outdoor S1-S2 V AC 208 / 230 Indoor - Outdoor S2-S3 V +12VDC to +24VDC Compressor Hermetic Fan Motor (ECM) kW 0.074 + 0.074 Sound Pressure Level Cooling dB(A) 49 Heating 53 External Dimensions (H x W x D) In / mm 52-11/16 x 41-11/32 x 13+1 1338 x 1050 x 330+25 Net Weight Lbs / kg 278 / 126 External Finish Munsell No. 3Y 7.8/11 Refrigerant Pipe Size O.D. — Branch Box Liquid In / mm 3/8 / 9.52 Gas 5/8 / 15.88 Max. Refrigerant Line Length Ft / m 492 (150) Max. Piping Length for Farthest Indoor Unit Ft / m 262 (80) Max. Refrigerant Pipe Height Difference If IDU is Below ODU Ft / m 131 (40) I If IDU is Above ODU 164 (50) Connection Method Indoor / Outdoor Flared/Flared Refrigerant R41OA *Rating Conditions per AHRI Standard: Cooling I Indoor: BOO F (27° C) DB / 67O F (19° C) W B Cooling I Outdoor: 950 F (35° C) DB / 750 F (240 C) W B Heating at 470F I Indoor: 70O F (210 C) DB Heating at 47OF I Outdoor: 470 F (80C) DB / 430 F (6* C) W B Heating at 170 F I Indoor: 700 F (210C) DB Heating at 17* F I Outdoor: 17* F (-8* C) DB / 150 F (-90 C) WB *1 Required in windy locations or areas that experience low temperatures. R-410A OZONE-FRIENOL, REFRIGERANT Specifications are subject to change without notice. M—BISxi EE Cthink. green © 2020 Mitsubishi Electric Sales Canada Inc. Page 1 of 5 Form # S13_MXZ-4C36NAHZ2-U1_202102a Operating Range: Energy Efficiencies: *1. D.B. 5 to 115° F [ D.B. -15 to 46° C ], when an optional Air Outlet Guide is installed. Multi -zone Indoor/Outdoor Combination Table - MXZ Compatibility Chart - available on MESCA Tech Info Centre M-Series submittal page * Refer to indoor unit submittal. Notes: • Minimum of two Indoor Units must be connected to the MXZ-4C36NAHZ. • Minimum installed capacity cannot be less than 12,000 Btu/h. • System can operate with only one Indoor Unit turned on. • May connect to any style indoor unit or combination. • Information provided at 208/230V. Refer to the MXZ-C Technical & Service Manual for detailed specifications and additional information per Indoor Unit Combination. SVZ CONNECTION RULES: • Up to 2 SVZ's may be connected to this system. • When 2 SVZ's are connected, no additional indoor units can be used. • When 1 SVZ is connected, additional indoor units can be connected. • When 1 SVZ is connected, total connected capacity must be less than 100%. Indoor - Outdoor Connection: Branch Box TEA T83A TB15 d c y OC s1 Si IC t A MA iT E y (51) s3 sa (01) z e L > y L E T83 TB1 t_1 TBS TB3B T83A TB75 •� C iM25 M1 M25 M1 S1 51 IC 1 A v C rnz sz s2 (02) z B MA 0 .2 L .2 S S3 S3 9 — � ca L O t.3 TB3C TLS2 TB75 m a a c ai E 3 O $7 1 A MA d d y^ sz z nw3 U d O O A c c `o E E01) w U O E C `O TB3D T83A ❑ N y O O st s7 IC RC C U o E £ L2 S2 S2 04) T O y N E E 53 S3 U U O R W N N T83A TB3E O w > U �. $7 S7 IC x C O Y c OC Sz Sz (05) s N y a0i A u tc (53) s3 s3 N N Cl J 0 _ c - + TB7 U _ C N — ..._.....: @ 7 E N E L4 TB3 TB3A TEB3ATB15 L R a y M1M2s M1M25 /��/`` Branch BOX S1 1 AN d Y a o $ o _.__._..._...; MA ON o�Sz z O- ja N U N S3) E N O J 2 J A Power SuPPIY \� N 'O N " unit II3S T838 T83A 3 4 to > } Cw J Imt (06) S1 s7 IC RC U r c i J E} Mt M2 S IN2 S2 S2 N Y R >= C >s } C J S S3 S3 (07) 3 a) Z i N y m a J DC24V Y Q O O y `o } J L5 System TB31 EA w w c w Y d y in -.,controller S1 C Q' O >. y y G1 J N J . 0 o a � E 3 6 ; �' + + M,M2SA :Shielded wire S3 E L Q :� F J J JJ ( ) : Address example Notes: Specifications are subject to change without notice. Outdoor Cooling D.B 23 to 115°F . [ D.B.-5 to 46°C ]*1 Heating D.B.-13to70°F[D.B.-25to21°C] Indoor Unit Type SEER EER HSPF tNM �p 47PF @ 107PF Non -ducted 20.0 14.0 11.3/9.2 3.95 NA Ducted and 18.7 13.2 11.1 /9.0 3.80 NA Non -ducted Ducted 17.5 12.5 11.0 /8.9 3.70 NA © 2020 Mitsubishi Electric Sales Canada Inc. Page 2 of 5 Form # SB_MXZ-4C36NAHZ2-U1_202102a Outdoor unit MXZ-4C36NAHZ2-U1 4HP Rated capacity (kBTU/h) Cooling 36 Heating 45 Refrigerant R410A Connectable indoor unit Capacity Type 06 to Type 36 Caution: The indoor unit which rated capacity exceeds 36 kBTU/ h (Type 36) can NOT be connected. Number of units 2 to 4 units Total system wide capacity 33 to 130% of outdoor unit capacity (12 to 46.8 kBTU/h) Connectable branch box Number of units 1 *or 2 units (*One SVZ model only) i - MXZ Compatibility Chart — available on MESCA Tech Info Centre M-Series submittal page "'A Branch box PAC-MKA52BC PAC-MKA32BC Number of branches 5 branches 3 branches / Indoor unit that (MAX. 5 units) (MAX. 3 units) lcan be connected Note: A maximum of 2 branch boxes can be connected to 1 outdoor unit. ■ If Using One Branch Box Flare connection employed (No brazing) ■ If Using Two Branch Boxes 2 branch pipe (joint) 0 optional parts A A Branch box #1 A B dbB \ 4)B 4)B 4)B Branch Box Combinations Three -port Five -port 1 0 0 1 1 1 2 0 0 2 (Up to 4 IDU) Piping connection size A B The piping connection size differs 09.52 mm according to the type and capacity of Liquid (3/8 inch) indoor units. Match the piping connection size of branch box with indoor unit. If the piping connection size of branch box does not match the piping connection size of indoor unit, use Gas 9515.88 mm optional different -diameter (deformed) (5/8 inch) joints to the branch box side. (Connect deformed joint directly to the branch box side.) nch box #2 ■ Installation procedure (2 branch pipe Ooint)) Refer to the installation manuals of MSDD-50AR-E and MSDD-50BR-E. Specifications are subject to change without notice. © 2020 Mitsubishi Electric Sales Canada Inc. Page 3 of 5 Form # SB_MXZ-4C36NAHZ2-U1_202102a 0 N 1 FREE SPACE(Around the unit) 12 SERVICE SPACE 13 FOUNDATION BOLTS 4 PIPING -WIRING DIRECTIONS The diagram below shows a basicexample. Dimensions of space needed Pleasesecuretheunhhrmly Piping and wiring connections Explanation of particular details are forserviceaccessare with4foundation (M10<W3/8>I bolts. an be made Rom 4directors: given in the installation manuals etc. showninthebelowdiagmm. (Bolts and washers must be Front, Right, Rear and Below. purchasedlocalfy.) <Foundation bolt height> �Sd Services ce _-_-_------ -_-_-_._-_-_-_-_-_- Min. 500 <19-11/16> Rear Airintake Side Airintake nn. Handlefor Handlefor Example of Notes coo"" coo n iO • • •Refrigerant GAS pipe connection (FIAREIOA " 0 • • • RefngerantLIQUID pipe connection (FLARE) 0952(3/8F) MI • • • Indication of9OP VALVE connection location. Piping Knock -Out Hole Details Side Air Intake i' Wheninstallingtheccoduit. Set the attachment to the in ner side of each panel. 6a12-3/8> 24<15/16> I 345<1�23/64> 1in[h(aMun 222<7/B> atb[hmem I _ �lrzmmca"daa c lapa[hmmt 101.5<4> '^ � _-_-_-_5cale15 mm <inch> I RearAnIntake 600 �Air Discharge Gmnd Forthe power supply 2XU Shaped notched holes 225 (Foundation BolM10CW3/8>) d7/32> Al e 6 a� 56<2-7/32> 40<1-37/64> 0 53<2-38b 42<1-21/32> - 60.5<2-3/8> M 2Xl2X36b,al holes Foundation BoltM10,0N ry erminal connection From left to right Forthe I Forthe orthe Forty powersuppfy branch box ransmistion line court powersuppty GTom ndforthetranemission line Ground no concentration control Service nel Handlefor PAC-M KA32BC SUSPENSION BOLT: W3/8(M10) REFRIGERANT PIPE FLARED CONNECTION Unit: inch A 113 C 1 1 TO OUTDOOR UNIT LIQUIDPIPE I 1/4F 1/4F 1/4F I I I 3/8F GAS PIPE 3/8F 3/8F 3/8F I I I 5/8F PAC-MKA52BC SUSPENSION BOLT W3/8(M10) REFRIGERANT PIPE FLARED CONNECTION Unit: inch A B C 1 D 1 E 1 TO OUTDOOR UNIT LIQUID PIPE I 114E 1114F I 1/4F I 114E I 114E I 3/8F GAS PIPE I 318E I 318E I 318E I 3/8F 1/21' 1 5/8F � C us OT Intertek Form # SB MXZ-4C36NAHZ2-U1 202102a Specifications are subject to change without notice. www. MitsubishiElectric.ca © 2020 Mitsubishi Electric Sales Canada Inc. SUSPENSION BOLT PITCH 320 (12-19132) SUSPENSION BOLT PITCH 320 (12-19/32) 98 (1M2) 280(11-1/32) 40(1-17132) AtMITSUBISHI ELECTRIC Changes for the Better Page 5 of 5 Unit: mm <inch> When installing the conduit. Set the attachment to the inner side of each panel. 58 (29/32) 0 1 (25132) C1332) NCI _ a���macyaamt 5 C19132 a 66 (2-79132) (12) Unit: mm <inch> When installing the conduit. Set the attachment to the inner side of each panel. 58 (29132) p (25132) (1-3I32) I m i a 12 inch Co utt attachment 15 C19132) to zi.J 88 (2-19/32) for a greener tomorrow •