APPROVED PLN BLD BLD2023-1384+SITE & ADDTL INFO +11.1.2023_9.16.23_AM+3873716PECK
9108 O.V.D.
EDMONDS WA
APPROVED
PLANS MUST BE
ON JOB SITE
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
City Of Edmonds
Building Department
--------------------------------
Work I GENERATOR
Address; 9108 OLYMPIC VIEW DR
------------------------
Owner: PECK
Approved Date 11/15/2023
Building Official I l7oxwas- W. X vfkarc
Permit Number
BLD2023-1384
skt
1 kc, +1c+yrc. ! I
i
The Following Documents and Plans to be on Site
at Time of Inspection:
1. Manufacturer in — I.— Requirements
2. M. Plan Stowing the Hight aM $etback.f the McM-n .i
Unit
3. L a ElecPicel Permit antl Inspecllon [e be Comple[etl at time of
City Inspection
RECEIVED
Nov 01 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
1
•
EL AA nb^ 93M
1GPSML4tv@ta=
f
Freehand Drawing Utility
("The Sandbox")
1,[Click here for the Gooale Maps version)
Use the toolbar on the right to add
waypoint markers and tracks, then click
one of the "save data" buttons to download
•- as plain text, GPX, or Google Earth KML.
Center the map on a location:
9108 oympic view dr edmor rG7O
OSM Nominatim found: 9108, Olympic View
Drive, Edmonds, Snohomish County,
Washington, 98026, United States
(47.83486,-122,35533) [precision: unknown]
1801216
10m
APPROVED BY PLANNFG
4-13-
Nov 21 2023
Zone RS-12 Corner.
X Flag,_
Setbacks:
Required
Actual
Front
25'
>25'
10,
>10
Sides
Rear
Other
Height
Noise generated by mechanical
equipment must meet the
standards in ECC 5.30
100% v OSM (OpenStreetMap.org) v IQ
Drawing tools:
_ f Q
t3� �
_' _
.... TiT. .
span wpt trk save data
Your map elements: ,r
[track 1]
[track 4]
[track 5]
11111111 Generator Location
Impart a GPS file Import a URL
,
.ength: 24.93 m {81.79 ft)
Link to this view
3
I from OpenStreetMap.org
RECEIVED
Brand Nov 01 2023
Gen Pad CITY OF EDMONDS
Model
SERVICES
Model DEPARTMENT
10000007852
Weight: 189 Pounds Product Length: 54" Product Width: 31"; Product Height: 3"
GenPadTr" Standard 3" Composite Cement Pad for Generac 9kW-26kW (2016+)
GenPadTm 3" Composite Cement Pad
• Meets engineering specs of 2016+ Generac air-cooled generators (9-26kW)
A Sturdy, Permanent Base For Residential Generators
• Won't shift, crack or degrade over time.
High -Quality Design - Gives A Finished, Professional Look To Your Installation
• Contoured to look aesthetically pleasing on your property
Composite Construction
• Made up of high strength fibers, foam and cement
• Structurally reinforced with rebar in the lower 1/3 of the pad
Flat Bottom Design
• Helps level the unit and prevents it from sinking
Installs Faster & Cleaner
• Just bolt generator directly to the pad
(3) 5" x 1/4-20 Non -Corrosive Zinc -Plated Bolts (Not Included)
Warrantied For The Life Of The Generator
RECEIVED
Nov 01 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
CI
jww-
.i
_ a
�- 77
It
A Solid Foundation for You
and Your Customers
The new GenPads" is the answer for dealers who need a professional looking pad that will
provide a lifetime base for their Genera& home backup generator installations.
Each GenPad is made from a composite of high strength fibers and cement and is
warranted for the life of the generator. These pads provide a sturdy, permanent base with
a professional appearance for the generator. Give your customers even more peace of
mind with their Generac generator purchase when you add the reliable GenPad.
GenPads are much lighter weight than a poured concrete pad and take less time and
effort to install. GenPads are made specifically to fit Generac 8-22kw home standby units.
GenPads were specifically designed to meet the engineering specifications of Generac
units. All GenPads are purchased directly from Generac and include these features:
• Extremely Impact and Breakage Resistant
• Fiber reinforced concrete that is further reinforced with rebar
• Flat bottom to facilitate easy leveling of the pad and generator
• Virtually eliminates sinking of the unit into the ground
• Easy to install
• 1/2 the weight of poured concrete
• Meets national gas code NFPA 37
Two models to meet any need
GenPad TM
Designed for residential installation.
CONTAINS
RECYCLED
MATERIALS
GenPad Hurricane TM
Thicker, heavier 4" pad desi..,iCc, N- rv?e
wind load requirements in hurricane
prone areas.
GenPad Program
Available in pallets of 2, 5 or 10 - volume discounts available
Dealers and distributors: Call today for pricing: 800-888-2069
GenPads are now available in
pallet quantities of ten, five and
two!
GenPads are the answer for dealers
who want a professional looldng
pad that provides a lifetime base for
Generac home standby generators.
• Pallets of ten pads can be
mixed with both sizes (ex:
quantity 8 OJ5339 and quantity 2
OJ5340 to make up one pallet of ten).
Due to weight limitations, all
shipments of 100 or more pads
in multiple sizes will be reviewed
by Generac prior to shipment,
3" GenPad Information
Generac
•..
Part Number Descfiphon
pw Pad
per Pallet
54"X31'x3"
1$9
�
OK0033 54' X 31' x 3"
184
5
CU 5339 54 ` X 31 ' x 3"
189
10
ad Hurricane information
W
x 31 " x 4"
275
2
54' x 31 ' x 4'
7W54'
275
554'
x 31' x 4"
275
10
FAQ:
Q: Is the GenPad approved by Generac for use with its generators%'
A; The GenPad is not only approved by Generac, but is only available for purchase from Generacl
Q: Why would I want to instaii a GenPad under a Generac unit?
A: The GenPad provides a solid, sturdy foundation for all 8-22 KW Generac produced generators and
eliminates the risk of uneven mounting surfaces. Many local area codes may also require a concrete base
for the generator. The GenPad also provides extra height off the ground for the generator.
Q. Can I install my Generac generator an the GenPad without removing the black composite mounting pad?
A: Yes, by leaving the block composite mounting pad attached to the generator with the back two bolts
and by removing the front two bolts, Place the generator, with the black composite mounting pad in
place, on top of the already placed and leveled GenPad. Align the bolt holes of any 8-22 KW Generac
produced generator with the inserts in the GenPad and attach together by using 3" long 3/8" bolts,
Installing with the black composite pad between the generator and GenPad also elevates the generator
so that the plastic fascia (standard with 20kw and available in kits for other sizes) can be used.
Q: What do I need to put undei aeath the GenPad?
A: The GenPad can be placed directly onto leveled ground. There is no need to place anything below it
to provide a stable platform with professional appearance.
Q: Why should I sell my customers a GenPad?
A; The GenPad provides a sturdy base for the Generac generator and helps protect it and keep it level to
maximize its performance and life. The GenPad is faster and easier to install than pouring a concrete pad
and makes an excellent accessory add -on when selling a new generator.
Q: Where is the GenPod Hurricane used?
A: The 4-inch GenPod Hurricane is a heavier, thicker pad that is ideal for high wind zone areas: Florida,
the Gulf Coast and the Tidewater region. They are also used for installations that require more ground
clearance. To view the wind load tables please visit: genpads.com/resources.html
Q If I have product related questions whom can I contact?
A: Please contact DiversiTech via email genpads@diversitech.com or call 1-800-888-2oR E C E IV E D
Other info: Noy 01 2023
Warranted for the life of the generator (through DiversiTech). 25% recycled material. Rebar reinforced.
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
rl
GenPad Benefit to Benefit to
Features Dealer Installer Real Value
Lightweight Easy to Stock Easy to Install, Saves Cost
saves time
Precision Fewer callbacks Easy to Install Saves Cost c .
Produced
Aesthetically Adds value to Better installation Adds to resale
Pleasing purchase value
Production Saves Saves Saves Cost
Product installation time/ installation time/ _
trips to job site trips to job site
Flat bottom Reduces/ Simple and quick Reduces/ _
Eliminates return to install Eliminates -
trips calling dealer
to return and
level the
generator
Q
ti