REVIEWED BLD2024-0007+Manufacturer_Specifications_and_Installation_Instructions+1.2.2024_1.07.18_PM+3978144R innai. RECEIVED Jan 02 1^ 1 BLD202 ■ FLEXIBLE VENTING OPTIONS • Concentric or Schedule 40 PVC/CPVC • Direct Vent (Concentric and Twin Pipe) • Non -Direct Vent (Room Air) • Common Vent (Direct Vent and Room Air) • Maximum Equivalent Vent Lengths: Twin Pipe Vent Sizes 2 in. (51 mm) 3 in. (76 mm) Vent Lengths 65 ft (20 m) 150 ft (46 m) Concentric Vent Sizes 2 in. X 4 in. 3 in. X 5 in. Vent Lengths 65 ft (20 m) 150 ft (46 m) ■ EASE OF INSTALLATION AND SERVICEABILITY • Compact Design to Save Space • Wi-Fi Technology for Remote Monitoring and Management • Sliding Mounting Bracket for Easy Installation • Simple Gas Conversion ■ OPTIONAL ACCESSORIES RESIDENTIAL SUPER -HIGH -EFFICIENCY (CONDENSING) TANKLESS WATER HEATER Installation Type Internal (Indoor) Residential Applications. Manufactured (Mobile) Home Certified Model Numbers RU199i (REU-N3237FF-US) RU180i (REU-N2934FF-US) RU160i (REU-N2530FF-US) RU130i (REU-N2024FF-US) Approved Gas Types Natural and Propane Efficiency emm UEF: 0.95 (RU199i, RU180i, RU160i) 0.91 (RU130i) Ratings not EF: 0.96 (RU199i) certified by AHRI 0.95 (RU180i, RU160i, RU130i) High Altitude Approved Up to 10,200 ft (3,109 m) Water Flow Control Water Flow Sensor, Electronic Water Control and Bypass Control Controller Standard: Integrated Controller Optional: MC-195T-US, MC-100V-1US, BC-100V-1US, MCC-91-2US Certifications AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR® Warranty • Heat Exchanger: 15 years or 12,000 operation hours, whichever occurs first • All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection Included with Purchase Tankless Water Heater, Wall Mounting Bracket, Pressure Relief Valve and Adapter, Isolation Valve Kit, Vent Screens (x2), Vent Screen Screws (x2) and Self -Tapping Screws (x2) Additional Features • Mobile Home Certified • 1/2 in. (13 mm) Gas Line Compatible • Ultra Low NOx • Complies with South Coast Air Quality • Tankless Rack Management District 14 ng/J or 20 ppm NOx System- Compatible Emission Levels Room Air Screen, Condensate Neutralizer, ScaleCutter, Drain oESICN Down Kit, Additional Controllers, Pipe Cover, Recirculation ca S Pump, DPS/MIS Switch, EZConnect-Cables, control•rTN CUS CERTIFIED �FRTIF FO® 70 LOW LEAD SANITATION Wi-Fi Module, Wireless Accessories, and many more. CONTENT Visit rinnai.us for a complete list of accessories. CERTIFIED TO ANSI Z21.10.3 — CSA 4.3 in. (mm) SPECIFICATION RU199i RU180i RU160i RU130i Dimensions - w, h, d 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm) Minimum Gas 15,000 Consumption Btu/h Maximum Gas Consumption Btu/h 199,000 180,000 160,000 130,000 Flow Rate' 0.26 - 9.8 GPM 0.26 - 9.0 GPM 0.26 - 8.0 GPM 0.26 - 6.6 GPM (Min - Max) (1.0 - 37 L/min) (1.0 - 34 L/min) (1.0 - 30 L/min) (1.0 - 24 L/min) Max Flow Rate with 11 GPM 10 GPM 9 GPM 7 GPM Parameter Adjustment (42 L/min) (38 L/min) (34 L/min) (26 L/min) Weight 64 lb (29 kg) 64 lb (29 kg) 62 lb (28 kg) 62 lb (28 kg) Sound Level 48 dB 47 dB 47 dB 47 dB Normal 84 W 65 W 52 W 38 W o Standby 1.3 W Freeze Protection 148 W a, w Max Current 4 Amps Fuse 10 Amps • Minimum: 98' F (37' C) Default Temperature • Maximum: 120° F (49' C) Default 140° F (60° C) With Parameter Adjustment By -Pass Flow Control Electronic Gas Supply Pressure • Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c. Ignition System Direct Electronic Ignition Electronic Connections • Appliance: AC 120 Volts, 60Hz. . Temperature Controller: DC 12 Volts (Digital) Water Supply Pressure • Minimum: 50 PSI (Recommended 60-80 PSI for max performance) • Maximum: 150 PSI Controller Cable Non -Polarized Two Core Cable (Minimum 22 AWG) • Gas Supply: 3/4 in. (19 mm) NPT Service Connections • Cold Water Inlet: 3/4 in. (19 mm) NPT • Hot Water Outlet: 3/4 in. (19 mm) NPT • Condensate Drain: 1/2 in. (13 mm) NPT • Top: 2 in. (51 mm)* • Back: 0 in. Clearances • Bottom/Ground: 12 in. (305 mm) • Sides: 2 in. (51 mm)*** • Front: 0 in.** • Vent: 0 in. * 0 in. from vent components ** Clearance for servicing is 24 in. (610 mm) in front of water heater *** Add 0.25 in. (6.35 mm) for recess box ' Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). 2 The maximum gas supply pressure must not exceed the value specified by the manufacturer. Flow curves apply only to incoming water temperatures of 70' F (21' C) or less. For incoming water temperatures greater than 70' F (21° C), please contact Rinnai. 12 „ L INnTF-Mnximtjm flow rates may v, 6 5 Q 4 0 3 2 a 1 3 0 FRONT 5.90 f1501 c c SIDE 6.08 (154) BOTTOM o zs so 75 100 125 iso DELTA T- TEMPERATURE RISE (°F) Rinnai America Corporation • 103 International Drive, Peachtree City, GA 30269 • 1-800-621-9419 • rinnai.us 02020 Rinnai America Corporation. Rinnai America Corporation continually updates materials, and as such, content is subject to change without notice. Local, state, provincial, federal and national fuel gas codes must be adhered to prior to and upon installation. LVASa Vent Connection: 2 in. (51 mm) nominal PVC/ Polypropylene or 3 in./5 in. Concentric. a0 N N n ConnectionCOLD F C 9.54 242 3.56 90 HOT H B 14.27 362 6.16 156 GAS E D 3.57 91 2.78 71 PRV G A 10.39 264 7.60 193 05/2023 Rui-SP-4 SENSEI•" Residential Indoor Spec Sheet