REVIEWED RESUB2 BLD2023-0273+Structural_Analysis_or_Calculations+9.29.2023_2.10.49_PM+3813193RESU B BLD2023-0273
Sep 29 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES DEPARTMENT Calculations
................................................
REVIEWED
BY
CITY OF EDMONDS
BUILDING DEPARTMENT: AUL TRIEU RESIDENCE
7011 LAKE BALLINGER WAY
EDMONDS, WA
AL
RCR Engineers PLLC
29028 176t" Ave SE
Kent, WA 98042
AUGUST 2, 2022
RCR ENGINEERS, PLLC Structural Engineers
29028 176"' AVE SE, Kent, WA 98042 (206) 295 9439
Project# Project PAUL & NANCY TRIEU Date 5-26-2022
Subject HIGH ROOF FRAMING Sheet R-1
DL=15psf
SL=25psf
WL= -22psf LRFD -15 PSF ASD
0 1 2 4 5 6
ar-r
Sa• !a tTl M NP
'�• rr r� m
F�F
OFFSET 12"
4X6 POST w/ECC COL CAP
@ RIDGE BM TYP
b H-3 /I H-10 H-4
I
R-2 -2 R-2 R-2 ill H-6
I
I
i 11 /• VERBUILD II
I
R-1 EGQ HANGER
co
I I
H- OVERBUILD I H-7
LLLr =_ L y R-2
�����...... --- ----
' L CCQ W/ 6X6 POST / OVERBUILD
`
H-2 1 ,
4X6 POST
/IT RB-5 RB-6 ; I w/ECC COL CAP
I II 1 AOQ 1
OVERBUILD Z ! 1 N
H-6 h
4X6 POST`_-
w/ECC COL CAP 1 1 1R-2 1 _�
y M i '
I - !L ---=== -- - --- EGQ HANGER
MSC HGR m m m
'
R-2 === `-� R-2 := 1 -- :_ - .. p== �i
H-8
R-2
y — H-5 H-5
R-1 2X12 DF#2 RAFTER @ 16"
R-2 2X12 DF#2 RAFTER @ 24" H-1 2-2X8 DF#2 x
H-2 3 1/2 X 11 7/8 LVL w/ 3 STUDS @ ENDS
VB-1 2-2X12 DF#2 H-3 5 1/4 X 7 1.8E PSL
H-4 5 1/4 X 7 1.8E PSL
RB-1 3 1/8 x 12 GLB H-5 2-2X6 DF#2
RB-2 3 1/8 X 13 1/2 GLB H-6 2-2X6 DF#2
RB-3 3 1/8 X 12 GLB H-7 2-2X6 DF#2
RB-4 3 1/8 X 15 GLB H-8 2-2X6 DF#2
R13-5 5 1/8 X 18 GLB H-9 5 1/4 X 7 1.8E PSL 6
RB-6 5 1/8 X 18 GLB H-10 2-2X6 DF#2
RCR ENGINEERS, PLLC Structural Engineers
Project#
Subject
Project PAUL TRIEU
ROOF FRAMING
DL=15psf
SL=25psf
WL= -22psf LRFD -15 PSF ASD
R-1 L = 19 MAX 2X12 DF#2 @ 16" LU28 HRG
29028 176`h AVE SE, Kent, WA 98042 (206) 295 9439
Date 5-26-22
R-2 L MAX = 13 FT 2X12 DF#2 @ 24 LU28 HGR
2 2.8
Sheet R-2
R=690#
E
13
F.5 R=1350#
VB-1 2-2X12 DF#2 7
RCR ENGINEERS. PLLC Structural Enizineers
29028 1761h AVE SE, Kent, WA 98042 (206) 295 9439
Project# Project PAUL TRIEU Date 5-26-22
Subject ROOF FRAMING Sheet R-3
DL=15psf
SL=25psf
WL= -22psf LRFD -15 PSF ASD
RB-1 L=15 FT TRIB= 6 FT
1 3/4 X 11 1/4 LVL R= 7.5D 1.2S -1.1W =1.92k COMBINED
RB-2 L = 20.5 FT TRIB = 8 MAX
3 1/8 X 12 GLB R = 1AD 2.1S -1.7W= 2.7k COMBINED
RB-3 L = 19 FT TRIB = 6.5 FT
3 1/8 X 12 GLB R = 1.OD 1.6S -1.4W= 2.6k COMBINED
RB-4 L = 21 FT TRIB =9.5 FT
3 1/8 X 15 GLB R = 1.7D 2.6S -2.2W= 4.2k COMBINED
RB-5 L = 23 FT
W1 TRIB=10
W2 TRIB =6.5
P1 = RB-3 D=1.Ok S=1.6k
+ VB-1 D=0.3 S=0.4
5 1/8 X 18 GLB
RB-6 L = 17 FT
W1 TRIB=2
P1 = RB-2 D=1.4k S=2.1 k
P2 = RB-4 D=1.7k S=2.6k
51/8X18
P1
W2 W2
W1
T6.5 13 23
R=8.1 R=7.9
PiI
8.5
W1 IP2
9.5 17
R=4.3 R=4.6
RCR ENGINEERS, PLLC Structural Engineers
Project#
Subject
Project PAUL TRIEU
ROOF FRAMING
DL=15psf
SL=25psf
WL= -22psf LRFD -15 PSF ASD
29028 176`h AVE SE, Kent, WA 98042 (206) 295 9439
Date 5-26-22
H-1 L = 3 TRIB = [19+2]/2 = 10.5 FT
2-2X8 DF#2
RB-5 +RB-6
H-2 L = 5.5 P=7.9D 10.1 S -4.3W
4.0
2 - 1 3/4 X 11 7/8 LVL
5.5
4.3 8.2
RB-2
H-3 L = 5 TRIB =3 FT
2.5
RB-2 1.1 D 1.6S -1.4W
5
5 1/4 X 7 1.8E PSL
1.5
H-4 L = 6 TRIB =3 FT SEE H-3
RB-2 1 AD 2.1 S -1.7W
5 1/4 X 7 1.8E PSL
H-5 L = 3.5 TRIB = 3 FT + 50PLF FOR WALL
2-2X6 DF#2
H-6 L = 3 TRIB = 18/2+2 = 11 FT + 50PLF FOR WALL
2-2X6 DF#2 R=0.8k
H-7 L = 3 TRIB = 18/2+2 = 11 FT + 50PLF FOR WALL
2-2X6 DF#2 R=0.8k
H-8 L = 3 TRIB = 20/2+2 = 12 FT + 50PLF FOR WALL
2-2X6 DF#2 R=0.8k
H-9 L = 5 TRIB =3 FT
RB-4 1.7D 2.6S -2.2W
5 1/4 X 7 1.8E PSL 5
R=2.4
H-10 L=3.5 TRIB=20/2+2=12FT
Sheet R-4
aFORTE'CM
Roof revision 5-22, Roof: Joist R-1
1 piece(s) 2 x 12 DF No.2 @ 16" OC
PASSED
0
WAIXIIII
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
a
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
533 @ 2.50"
2231 (3.50")
Passed (24%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
469 @ 1' 2.17"
2329
Passed (20%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
2499 @ 9' 9.50"
3138
Passed (80%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.395 @ 9' 9.50"
1.010
Passed (L/614)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.645 @ 9' 9.50"
1.347
Passed (L/376)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A 15% increase in the moment capacity has been added to account for repetitive member usage.
• Applicable calculations are based on Nos.
Bearing Length
Loads to Supports (Ibs)
Total
Available
Required
Dead
Snow
Wind
Total
Supports '
Accessories
1 - Beveled Plate - SPF
3.50"
3.50"
1.50"
206
326
-287
287
Blocking
2 - Beveled Plate - SPF
3.50"
3.50"
1.50"
206
326
-287
287
Blocking
• 151ocKing vaneis are assumea to carry no ioaas appiea aireary aoove tnem ana the run ioaa is appnea to the memoer Deing aesignea.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
5' 0.00" o/c
Bottom Edge (Lu)
20' 8.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Load
Location (Side)
Spacing
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
1 - Uniform (PSF)
0 to 19' 7.00"
16"
15.0
25.0
-22.0
Default Load
0
Member Length : 20' 11.46"
System : Roof
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 4/12
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
5/26/2022 6:38:20 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
Roof revision 5-22, Roof: Joist R-2
1 piece(s) 2 x 12 DF No.2 @ 24" OC
PASSED
71
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
0
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
534 @ IT 3.50"
1406 (1.50")
Passed (38%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
461 @ 12' 4.83"
2329
Passed (20%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
1746 @ 6' 9.00"
3138
Passed (56%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.129 @ 69.00"
0.690
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.210 @ 69.00"
0.919
Passed (L/788)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A 15% increase in the moment capacity has been added to account for repetitive member usage.
• Applicable calculations are based on Nos.
Bearing Length
Loads to Supports (Ibs)
Total
Available
Required
Dead
Snow
Wind
Total
Supports '
Accessories
1 - Beveled Plate - DF
3.50"
3.50"
1.50"
213
337
-297
297
Blocking
2 - Hanger on 11 1/4" DF beam
3.50"
Hanger'
1.50"
216
342
-301
5301
See note'
• rslocKing Panels are assumea to carry no ioaas appllea alrecoy aoove mem ana the Pull ioaa is appnea to the member Deing aesignea.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• ' See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
8' 5.00" o/c
Bottom Edge (Lu)
14' 0.00" o/c
-Maximum allowable bracing intervals based on applied load.
0
Member Length : 14' 3.88"
System : Roof
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 4/12
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
2 - Face Mount Hanger
LRU28Z
1.94"
N/A
6-10dxl.5
5-10d
• Reter to manufacturer notes and instructions for proper installation and use of all connectors.
Vertical Load
Location (Side)
Spacing
Dead
(0.90)
Snow
(1.1S)
Wind
(1.60)
comments
1 - Uniform (PSF)
0 to 13' 7.00"
24"
15.0
25.0
-22.0
Default Load
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
5/26/2022 6:43:46 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
Roof revision 5-22, Roof: Hip/Valley Beam VB-1 rev
2 piece(s) 2 x 12 DF No.2
PASSED
Sloped Length: 157.96
.44 F i
14' 9.18'
1
a o
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1344 @ 2.00"
4463 (3.50")
Passed (30%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1040 @ 1' 2.31"
4658
Passed (22%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
3701 @ 6' 4.82"
5458
Passed (68%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.148 @ 7' 2.35"
0.759
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.264 @ T 2.56"
1.012
Passed (L/690)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Supports Available Required
Loads to Supports (Ibs)
Accessories
Dead
Snow
Total
1 - Beveled Plate - SPF 3.50"
3.50"
1.50"
577
767
1344
Blocking
2 - Hanger on 11 1/4" SPF beam 3.50"
Hanger-
1.50"
312
371
683
See note'
• blOCKIng Panels are assumea to carry no loans appllea alrectly aoove mem ana me rull loaa Is appllea to me memoer Deing aeslgnea.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
12' 10.00" o/c
Bottom Edge (Lu)
154.00" o/c
-Maximum allowable bracing intervals based on applied load.
0
Member Length : 15' 7.54"
System : Roof
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 3.44/12
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
2 - Face Mount Hanger
LSSR210-2Z
1.88"
N/A
22-16dx2.5
18-16dx2.5
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 14' 9.18"
N/A
8.6
1 - Tapered (PLF)
0 to 14' 9.18"
N/A
98.6 to 0.0
154.1 to 0.0
Generated from
Roof Geometry
Weyerhaeuser Notes E
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/7/2022 3:19:55 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
Roof revision 5-22, Roof: Drop Beam RB-1
1 piece(s) 1 3/4" x 11 1/4" 2.0E Microllam@ LVL
PASSED
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1915 @ 2.00"
2603 (3.50")
Passed (74%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1613 @ 1' 2.75"
4302
Passed (37%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
7144 @ 7' 9.50"
9279
Passed (77%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.465 @ T 9.50"
0.762
Passed (L/393)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.762 @ 7' 9.50"
1.017
Passed (L/240)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length
Loads to Supports (Ibs)
Total
Available
Required
Dead
Snow
Wind
Total
Supports
Accessories
1 - Stud wall - SPF
3.50"
3.50"
2.57"
746
1169
1029
1915/-
Blocking
1029
2 - Stud wall- SPF
3.50"
3.50"
2.57"
746
1169
-1029
1915/-
Blocking
1029
• blocking Panels are assumed to carry no loads applied directly above them and the Lull load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
4' 11.00" o/c
Bottom Edge (Lu)
15' 7.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 15' 7.00"
N/A
5.7
1 - Uniform (PSF)
0 to 15' 7.00" (Front)
60.00"
15.0
25.0
-22.0
Default Load
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 0/12
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
5/26/2022 8:49:58 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTEWEB'
Roof revision 5-22, Roof: Drop Beam RB-2 rev
1 piece(s) 3 1/8" x 13 1/2" 24F-V4 DF Glulam
PASSED
r
I
F41Yj11Itl
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3481 @ 2.00"
4648 (3.50")
Passed (75%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
3014 @ 1' 5.00"
8571
Passed (35%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
17774 @ 10' 6.50"
21832
Passed (81%)
1.15
1.0 D + 1.0 S (All Spans)
Neg Moment (Ft-Ibs)
-961 @ 10' 6.50"
23414
Passed (4%)
1.60
0.6 D + 0.6 W (All Spans)
Live Load Defl. (in)
0.723 @ 10' 6.50"
1.038
Passed (L/344)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
1.194 @ 10' 6.50"
1.383
Passed (L/208)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 20' 9.00".
• Critical negative moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 20' 9.00".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Wind
Factored
1 - Stud wall- SPF
3.50"
3.50"
2.62"
1373
2108
-1687
3481/-188
Blocking
2 - Stud wall - SPF
3.50"
3.50"
2.62"
1373
2108
-1687
3481/-188
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
13' 4.00" o/c
Bottom Edge (Lu)
21' 1.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 21' 1.00"
N/A
10.3
1 - Uniform (PSF)
0 to 21' 1.00" (Front)
8' 0.00"
15.0
25.0
-20.0
Default Load
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 0/12
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
8/12/2023 9:01:56 PM UTC
ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
Roof revision 5-22, Roof: Drop Beam RB-3
1 piece(s) 3 1/8" x 12" 24F-V4 DF Glulam
PASSED
C,verall Length: 19 -
1910.001,
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2635 @ 2.00"
4648 (3.50")
Passed (57%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
2287 @ 1' 3.50"
7619
Passed (30%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
12465 @ 9' 9.50"
17250
Passed (72%)
1.15
1.0 D + 1.0 S (All Spans)
Neg Moment (Ft-Ibs)
-1011 @ 9' 9.50"
18500
Passed (5%)
1.60
0.6 D + 0.6 W (All Spans)
Live Load Defl. (in)
0.620 @ 9' 9.50"
0.962
Passed (L/373)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
1.026 @ 9' 9.50"
1.283
Passed (L/225)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 19' 3.00".
• Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 19' 3.00".
• -214 Ibs uplift at support located at 2.00". Strapping or other restraint may be required.
• -214 Ibs uplift at support located at 19' 5.00". Strapping or other restraint may be required.
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on Nos.
Bearing Length
Loads to Supports (Ibs)
Total
Available
Required
Dead
Snow
Wind
Total
Supports
Accessories
1 -Stud wall -SPF
3.50"
3.50"
1.98"
1044
1591
-1400
2635/
Blocking
1400
1400
2 -Stud wall -SPF
3.50"
3.50"
1.98"
1044
1591
-1400
2635/
Blocking
1400
1400
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
18' 8.00" o/c
Bottom Edge (Lu)
19' 7.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Snow
(1.15) L
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 19' 7.00"
N/A
9.1
1 - Uniform (PSF)
0 to 19' 7.00" (Front)
66.00"
15.0
25.0
-22.0
Default Load
Notes
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 0/12
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/7/2022 3:34:00 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
Roof revision 5-22, Roof: Drop Beam RB-4
1 piece(s) 3 1/8" x 15" 24F-V4 DF Glulam
PASSED
C,verall Length: 21 -
21' 0.00"
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
4224 @ 2.00"
4648 (3.50")
Passed (91%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
3620 @ 1' 6.50"
9523
Passed (38%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
22092 @ 10' 9.50"
26953
Passed (82%)
1.15
1.0 D + 1.0 S (All Spans)
Neg Moment (Ft-Ibs)
-1866 @ 10' 9.50"
28906
Passed (6%)
1.60
0.6 D + 0.6 W (All Spans)
Live Load Defl. (in)
0.689 @ 10' 9.50"
1.063
Passed (L/370)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
1.135 @ 10' 9.50"
1.417
Passed (L/225)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 21' 3.00".
• Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 21' 3.00".
• -357 Ibs uplift at support located at 2.00". Strapping or other restraint may be required.
• -357 Ibs uplift at support located at 21' 5.00". Strapping or other restraint may be required.
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on Nos.
Bearing Length
Loads to Supports (Ibs)
Total
Available
Required
Dead
Snow
Wind
Total
Supports
Accessories
1 -Stud wall -SPF
3.50"
3.50"
3.18"
1661
2563
-2255
4224/
Blocking
225555
2 -Stud wall -SPF
3.50"
3.50"
3.18"
1661
2563
-2255
42 24/
Blocking
225555
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
11' 4.00" o/c
Bottom Edge (Lu)
21' 7.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Snow
(1.15) L
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 21' 7.00"
N/A
11.4
--
--
1 - Uniform (PSF)
0 to 21' 7.00" (Front)
9' 6.00"
15.0
25.0
-22.0
Default Load
Notes
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 0/12
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
5/31/2022 2:45:15 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
Roof revision 5-22, Roof: Drop Beam RB-5
1 piece(s) 5 1/8" x 18" 24F-V4 DF Glulam
PASSED
I
Overall Length: 231 _
i#ir1KIN
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
7885 @ 23' 7.00"
16656 (5.00")
Passed (47%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
7273 @ 1' 11.50"
18742
Passed (39%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
46051 @ 11' 4.37"
60504
Passed (76%)
1.15
1.0 D + 1.0 S (All Spans)
Neg Moment (Ft-Ibs)
-1082 @ 17' 4.15"
68265
Passed (2%)
1.60
0.6 D + 0.6 W (All Spans)
Live Load Defl. (in)
0.614 @ 11' 10.02"
1.163
Passed (L/454)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
1.023 @ 11' 9.97"
1.550
Passed (L/273)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 0.95 that was calculated using length L = 23' 3.00".
• Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 12' 7.47".
• -341 Ibs uplift at support located at 23' 7.00". Strapping or other restraint may be required.
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on Nos.
Bearing Length
Loads to Supports (Ibs)
Supports -
Accessories
vailable
Required
Dead
Snow
Wind
Total
1 -Stud wall- DF
5.50"
5.50"
2.53"
3251
4849
-2974
8100/
Blocking
2974
2974
2 -Column Cap -steel
5.00"
5.00"
2.37"
3140
4744
-3708
7884/
Blocking
3708
3708
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
23' 11.00" o/c
Bottom Edge (Lu)
23' 11.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Snow
(1.1S)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 23' 10.50"
N/A
22.4
1 - Uniform (PSF)
0 to 23' 10.50" (Front)
1010.001,
15.0
25.0
-22.0
UNIFORM
2 - Uniform (PSF)
13' 0.00" to 23' 0.00" (Front)
66.00"
15.0
25.0
-22.0
UNF RT
3 - Point (lb)
6' 6.00" (Front)
N/A
1300
2000
P1
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 0/12
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/7/2022 3:42:56 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTEWEB'
Roof revision 5-22, Roof: Drop Beam RB-6 rev
1 piece(s) 5 1/8" x 18" 24F-V4 DF Glulam
PASSED
r-
I
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
17
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
4683 @ 2.00"
11659 (3.50")
Passed (40%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
4734 @ 15' 9.50"
18742
Passed (25%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
35588 @ 9' 6.00"
62337
Passed (57%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.215 @ 8' 10.35"
0.863
Passed (L/964)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.365 @ 8' 10.33"
1.150
Passed (L/567)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume/size factor of 0.98 that was calculated using length L = 17' 3.00".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on Nos.
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Factored
1 - Column Cap - steel
3.50"
3.50"
1.50"
1965
2718
4683
Blocking
2 - Stud wall - DI
5.50"
5.50"
1.54"
2066
2869
4935
Blocking
• blocking Panels are assumeo to carry no ioaos appueo oirectiy aoove tnem ano the twi ioao is appueo to the memoer oemg oesigneo.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
IT 9.00" o/c
Bottom Edge (Lu)
IT 9.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Snow
0 - Self Weight (PLF)
0 to 17' 9.00"
N/A
22.4
1 - Uniform (PSF)
0 to 17' 9.00" (Front)
2' 0.00"
15.0
25.0 wl
2 - Point (lb)
8' 6.00" (Front)
N/A
1400
2100 Pi
3 - Point (lb)
9' 6.00" (Front)
N/A
1700
2600 P2
0
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 0/12
Weyerhaeuser Notes V �011!" gp
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
8/12/2023 9:06:14 PM UTC
ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
Roof, Wall: Header H-1
2 piece(s) 2 x 8 DF No.2
PASSED
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
691 @ 0
2813 (1.50")
Passed (25%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
381 @ 8.75"
3002
Passed (13%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
562 @ 1' 7.50"
2720
Passed (21%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.004 @ 1' 7.50"
0.108
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.007 @ 1' 7.50"
0.162
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Supports
Accessories
Total
Available
Required
Dead
Snow
Wind
Total
1 - Trimmer - SPF
1.50"
1.50"
1.50"
265
427
-375
692/
None
375
2 - Trimmer - SPF
1.50"
1.50"
1.50"
265
427
-375
692/
None
375
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
3' 3.00" o/c
Bottom Edge (Lu)
3' 3.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 3' 3.00"
N/A
5.5
1 - Uniform (PSF)
0 to 3' 3.00"
10' 6.00"
15.0
25.0
-22.0
Default Load
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
5/31/2022 3:21:45 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
Roof, Wall: Header H-2
1 piece(s) 5 1/8" x 12" 24F-V4 DF Glulam
PASSED
Overall Length: b 3.00
5' 6.00' I,
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
11068 @ 6' 0.00"
14991 (4.50")
Passed (74%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
11048 @ 4' 10.50"
12495
Passed (88%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
22100 @ 4' 0.00"
28290
Passed (78%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.046 @ 3' 3.60"
0.192
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.077 @ 3' 3.59"
0.287
Passed (L/895)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 5' 9.00".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Supports
Accessories
Total
Available
Required
Dead
Snow
Wind
Total
1 -Trimmer - DF
4.50"
4.50"
1.78"
2412
3513
-1809
5925/
None
1809
1809
2 - Trimmer - DF
4.50"
4.50"
3.32"
4481
6587
-3391
11068/-
None
one
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
6' 3.00" o/c
Bottom Edge (Lu)
63.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 6' 3.00"
N/A
14.9
--
--
1 - Point (Ib)
4' 0.00"
N/A
6800
10100
-5200
Default Load
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
5/31/2022 3:28:16 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
Roof revision 5-22, Wall: Header H-3
1 piece(s) 5 1/4" x 7" 1.8E Parallam@ PSL
PASSED
o t o
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1519 @ 1.50"
8584 (3.00")
Passed (18%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1507 @ 10.00"
6480
Passed (23%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
3562 @ 2' 6.00"
10905
Passed (33%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.038 @ 2' 6.00"
0.175
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.064 @ 2' 6.00"
0.262
Passed (L/977)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length
Loads to Supports (Ibs)
Total
Available
Required
Dead
Snow
Wind
Total
Supports
Accessories
1 -Trimmer - DF
3.00"
3.00"
1.50"
637
882
-772
1772
None
2 -Trimmer - DF
3.00"
3.00"
1.50"
533
730
-638
1638/
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
5' 6.00" o/c
Bottom Edge (Lu)
5' 6.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
comments
0 - Self Weight (PLF)
0 to 5' 6.00"
N/A
11.5
1 - Uniform (PSF)
0 to 5' 6.00"
0
15.0
25.0
-22.0
Default Load
2 - Point (lb)
2' 6.00"
N/A
1100
1600
-1400
RB-2
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
5/31/2022 4:22:07 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTEWEB'
Roof revision 5-22, Wall: Header H-4
1 piece(s) 5 1/4" x 7" 1.8E Parallam@ PSL
PASSED
Overall Length: 66.00
(. 6' 0.00' i,
1
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1938 @ 1.50"
8584 (3.00")
Passed (23%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1926 @ 10.00"
6480
Passed (30%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
5506 @ 3' 0.00"
10905
Passed (50%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.079 @ 3' 0.00"
0.208
Passed (L/948)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.133 @ 3' 0.00"
0.313
Passed (L/562)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
_
Accessorie
Total
Available
Required
Dead
Snow
Wind
Factored
1 - Trimmer - DF
3.00"
3.00"
1.50"
797
1141
-924
1938/-76
None
2 - Trimmer - DF
3.00"
3.00"
1.50"
685
973
-788
1658/-62
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
66.00" o/c
Bottom Edge (Lu)
66.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 6' 6.00"
N/A
11.5
1 - Uniform (PSF)
0 to 6' 6.00"
0
15.0
25.0
-22.0
Default Load
2 - Point (Ib)
3' 0.00"
N/A
1400
2100
-1700
RB-2
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
8/12/2023 9:09:52 PM UTC
ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
Roof, Wall: Header H-5
2 piece(s) 2 x 6 DF No.2
PASSED
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
327 @ 0
2813 (1.50")
Passed (12%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
225 @ 7.00"
2277
Passed (10%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
306 @ 1' 10.50"
1696
Passed (18%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.005 @ 1' 10.50"
0.125
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.012 @ 1' 10.50"
0.188
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Supports
Accessories
Total
Available
Required
Dead
Snow
Wind
Total
1 - Trimmer - SPF
1.50"
1.50"
1.50"
186
141
-124
124
None
2 - Trimmer - SPF
1.50"
1.50"
1.50"
186
141
-124
327/
None
124
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
3' 9.00" o/c
Bottom Edge (Lu)
3' 9.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 3' 9.00"
N/A
4.2
1 - Uniform (PSF)
0 to 3' 9.00"
T 0.00"
15.0
25.0
-22.0
Default Load
2 - Uniform (PLF)
0 to 3' 9.00"
N/A
50.0
-
-
WALL
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
5/31/2022 3:43:21 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
Roof, Wall: Header H-6
2 piece(s) 2 x 6 DF No.2
PASSED
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
803 @ 0
2813 (1.50")
Passed (29%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
515 @ 7.00"
2277
Passed (23%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
652 @ 1' 7.50"
1696
Passed (38%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.010 @ 1' 7.50"
0.108
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.019 @ 1' 7.50"
0.162
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Supports
Accessories
Total
Available
Required
Dead
Snow
Wind
Total
1 - Trimmer - SPF
1.50"
1.50"
1.50"
356
447
-393
8393
None
2 - Trimmer - SPF
1.50"
1.50"
1.50"
356
447
-393
803/
None
393
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
3' 3.00" o/c
Bottom Edge (Lu)
3' 3.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 3' 3.00"
N/A
4.2
1 - Uniform (PSF)
0 to 3' 3.00"
1110.0011
15.0
25.0
-22.0
Default Load
2 - Uniform (PLF)
0 to 3' 3.00"
N/A
50.0
-
-
WALL
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
5/31/2022 4:10:22 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
Roof revision 5-22, Wall: Header H-7
2 piece(s) 2 x 6 DF No.2
PASSED
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1288 @ 0
2813 (1.50")
Passed (46%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
999 @ 7.00"
2277
Passed (44%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
1376 @ 1' 6.00"
1696
Passed (81%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.020 @ 1' 7.47"
0.108
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.035 @ 1' 7.47"
0.162
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Supports
Accessories
Total
Available
Required
Dead
Snow
Wind
Total
1 -Trimmer -SPF
1.50"
1.50"
1.50"
572
716
-393
1393/
None
2 - Trimmer - SPF
1.50"
1.50"
1.50"
541
678
-393
1 19
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
3' 3.00" o/c
Bottom Edge (Lu)
3' 3.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 3' 3.00"
N/A
4.2
1 - Uniform (PSF)
0 to 3' 3.00"
1110.0011
15.0
25.0
-22.0
Default Load
2 - Uniform (PLF)
0 to 3' 3.00"
N/A
50.0
-
-
WALL
3 - Point (lb)
1' 6.00"
N/A
400
500
VB-3
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
5/31/2022 4:13:45 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
Roof revision 5-22, Wall: Header H-8
2 piece(s) 2 x 6 DF No.2
PASSED
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
868 @ 0
2813 (1.50")
Passed (31%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
556 @ 7.00"
2277
Passed (24%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
705 @ 1' 7.50"
1696
Passed (42%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.011 @ 1' 7.50"
0.108
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.020 @ 1' 7.50"
0.162
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Supports
Accessories
Total
Available
Required
Dead
Snow
Wind
Total
1 - Trimmer - SPF
1.50"
1.50"
1.50"
381
488
-429
8429
None
2 - Trimmer - SPF
1.50"
1.50"
1.50"
381
488
-429
869/
None
429
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
3' 3.00" o/c
Bottom Edge (Lu)
3' 3.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 3' 3.00"
N/A
4.2
1 - Uniform (PSF)
0 to 3' 3.00"
12' 0.00"
15.0
25.0
-22.0
Default Load
2 - Uniform (PLF)
0 to 3' 3.00"
N/A
50.0
-
-
WALL
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
5/31/2022 4:16:33 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
Roof revision 5-22, Wall: Header H-9
1 piece(s) 5 1/4" x 7" 1.8E Parallam@ PSL
PASSED
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2396 @ 1.50"
8584 (3.00")
Passed (28%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
2383 @ 10.00"
6480
Passed (37%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
5643 @ 2' 6.00"
10905
Passed (52%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.061 @ 2' 6.00"
0.175
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.102 @ 2' 6.00"
0.262
Passed (L/618)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length
Loads to Supports (Ibs)
Total
Available
Required
Dead
Snow
Wind
Total
Supports
Accessories
1 -Trimmer- DF
3.00"
3.00"
1.50"
966
1430
-1210
2396/
None
1210
1z10
2 -Trimmer - DF
3.00"
3.00"
1.50"
804
1182
-1000
1986/
None
500 000
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
5' 6.00" o/c
Bottom Edge (Lu)
5' 6.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
comments
0 - Self Weight (PLF)
0 to 5' 6.00"
N/A
11.5
1 - Uniform (PSF)
0 to 5' 6.00"
0
15.0
25.0
-22.0
Default Load
2 - Point (lb)
2' 6.00"
N/A
1700
2600
-2200
RB-2
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
5/31/2022 4:19:45 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
Roof revision 5-22, Wall: Header H-10
2 piece(s) 2 x 6 DF No.2
PASSED
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1002 @ 0
2813 (1.50")
Passed (36%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
690 @ 7.00"
2277
Passed (30%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
939 @ 1' 10.50"
1696
Passed (55%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.020 @ 1' 10.50"
0.125
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.036 @ 1' 10.50"
0.188
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on Nos.
Bearing Length
Loads to Supports (Ibs)
Supports
Accessories
Total
Available
Required
Dead
Snow
Wind
Total
1 -Trimmer -SPF
1.50"
1.50"
1.50"
439
563
-495
1495/
None
2 - Trimmer - SPF
1.50"
1.50"
1.50"
439
563
-495
1495/
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
3' 9.00" o/c
Bottom Edge (Lu)
3' 9.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 3' 9.00"
N/A
4.2
1 - Uniform (PSF)
0 to 3' 9.00"
12' 0.00"
15.0
25.0
-22.0
Default Load
2 - Uniform (PLF)
0 to 3' 9.00"
N/A
50.0
-
-
WALL
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/1/2022 5:31:36 PM UTC
ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
RCR
00
ENGINEERS,
PLLC Structural Engineers
29028 176r" AVE SE, Kent,
WA 98042 (206) 295 9439
Project#
Project PAUL & NANCY TRIEU
Date 3-1-2022
Subject
2ND FLOOR FRAMING
T-1 TRUSS @ 24"
Sheet 2ND-1
DL=15
J-1 11 7/8 TJI 210 @ 12"
B-1 3 1/8 X 12 GLB
LL=40 / 60 DECKS
J-2 11 7/8 TJI 110 @ 16"
B-2 4X8 DF#2
SL=25
J-2A 3 1/2 X 11 7/8 LVL W/ HHUS HGR
B-3 3 1/2 X 11 7/8 1.55E LSL
WLroof=-22 LRFD
J-3 11 7/8 TJI 110 @ 16 IUS HGR"
B-4 NA
J-4 1 3/4 X 11 7/8 LVL HUS HGR
B-5 3 112 X 11 7/8 LSL
B-6 5 1/8 X 13 1/2 GLIB
B-7 1 3/4 X 11 7/8 LSL U14 HGR
0 1
a
B-8 2- 1/3/4 X 11 7/8 LVL
Q
B-9 2-2X6 DF#2
r>
o 0
B-10 1 3/4 X 11 7/8 LVL
z 0 06 s
B-11 3 1/2 X 11 7/8 LVL
•.
..
`
w z_ w
PrB-12
3 1/2 X 11 7/8 LVL
B
2 �� O
B-13 W12X19
B-1
L m
O Q
B-14 W16X26
w
--
B-15 3 1/2 X 7 PSL 2 JACKS STUDS
A
B-16 2-1 3/4 X 11 7/8 LVL
O
3
_ _ - >
_
��
B-17 4X10 DF#2
r
B-2
B-18 4X10 DF#2
O
± H-3
H-4
B-19 4X10 DF#2
e
J
=
-
H-1 2-2X6 DF#2
H-5
H-2 NA
H-3 2-2X6 DF#2
A
H-4 5 1/8 X 15 GLIB
J-2
H-5 2- 1 3/4 X 9 1/2 LVL 3 JACK STUDS
H-6 2-2X6 DF#2
m
H-7 2-2X6 DF#2
H-8 2-2X6 DF#2
-FL
H-6
J-2
H-9 2-2X6 DF#2
B-5
H-10 2-2X8 DF#2
co
H-11 2-2X8 DF#2
J-2
2
H-12 2-2X8 DF#2
B-8
J- S
- J-2 _ 3
rn ti
0o m F
LO N ROOF
J-2 J-2
°° i B 12 J-1 2
F.5 =
Cl)
F.8 B-11 00 m m
B-14
F.9
H-1I H-1 T-2 m
-- i T-2
- H
- -- -
B-18 B
LOW ROOF - - -
M tK
ENTRY RF "` H-1 LOW ROOF
B-19 ,
RCR ENGINEERS. PLLC Structural Enizineers
29028 1761h AVE SE, Kent, WA 98042 (206) 295 9439
Project# Project PAUL TRIEU Date 3-6-22
Subject UPPER FLOOR / LOW ROOF FRAMING Sheet 2ND-2
DL=15
LL=40 / 60 DECKS
SL=25
WLroof=-22 LRFD
LOW ROOF
T-1 T-2 TRUSS @ 24 PER MANUF
B-1 L =16.5 FT TRIB = 11.5^2/2/9.5= 7.0 FT
3 1/8 X 12 GLB R= 2.5k
B-2 L= 9.5 FT TRIB = 4.5 FT
4X8 DF#2 R= 0.94K
B-3 L= 18.5 TRIB = 7112/2/5 = 5 FT
3 1/2 X 11 7/8 1.55E LSL R= 2.0 k W/ SINGLE JACK STUD
2ND FLR
H-1 L = 3.5 TRIB = 7.5A2/2/6 = 5 FT + 50 PLF WALL
2-2X6 DF#2
H-2 L = 3.5 TRIB = 7.5A2/2/6 = 5 FT
4X6 DF#2
J-1 L MAX = 19 FT
11 7/8 TJ 1210 @ 12"
J-2 L MAX = 16.5 FT
11 7/8 TJ 1110 @ 16"
J-2A L MAX = 16.5 FT TRIB = 4FT WALL=4*250D 4*25*10S
2- 1 3/4 X 11 7/8 LVL W HHUS HGR
J-3
P1 = 30PLF + 100 WALL D 50PLF S
P2 FROM H4 RF 0.8 D 1.2S
11 7/8 TJI 110 @ 16" W/ IUS HGR @ BM
J-4
P1 = 30PLF + 100 WALL D 50PLF S
P2 FROM H4 RF 0.8 D 1.2S
1 3/4X11 7/8 LVL @ 16" W/ HUS HGR @ BM
P=3.8D 3.21- 2.7S B-13
2.5
3.5
TRIPLE
STUD
WALL TRIB =1 OFT
1.0
T 16.5 7
P1 / P2
6 2
RCR ENGINEERS, PLLC Structural Engineers
Project#
Subject
Project
29028 176`h AVE SE, Kent, WA 98042 (206) 295 9439
PAUL TRIEU Date 3-7-22
UPPER FLOOR / LOW ROOF FRAMING
DL=15
LL=40 / 60 DECKS
SL=25
WLroof=-22 LRFD
B-5 L= 17.33
FLOOR TRIB = 2 FT
RAIL = 100 PLF
3 1/2 X 11 7/8 LSL
B-6 L= 14 FT
2ND FLR TRIB = 8.5 FT
RF TRIB = [2+16.5/2]/2 = 5.5FT
WALL = 100PLF
3 1/8 X 13 1/2 GLB
B-7 L= 4 FT TRIB = 7 FT
1 3/4 X 11 7/8 LSL U14 HGR
B-8 L= 17.33 TRIB = 2
100 PLF WALL OVER FOR 11 FT
2- 1/3/4 X 11 7/8 LVL
B-9 L= 5.0
FLR TRIB = 3FT
2-2X6 DF#2
B-10 L=6+6
W1 RF TRIB = [6.5+5]/2=6 FT
W1 FLR TRIB=14/2=7
W2 RF TRIB = 5/2+1.5 = 4
WALL = 100PLF
1 3/4 X 11 7/8 LVL
B-11
RF TRIB = 6/2+2 =SFT
FLR TRIB = 2FT
WALL = 100PLF
RB-31.05D 1.6S
3 1/2 X 11 7/8 LVL
B-12 L=9.5
RF TRIB =8 FT
FLR TRIB = 2 FT
WALL = 100PLF
3 1/2 X 11 7/8 LVL
14 1
R=6 R=6k
SEE B-7 R=.SD 1.2L
11
R=2.5 =2.5
Wo W1
t.6 1 0 .1
RB-3 rf
6.5 2.01
11.5
RI =3.4 R=9.5
SEE B-10 1.8D 1.2L 1.OS
SEE B-10 + VB-1
.8+.6D 1.OL .4-.8S RF .6D .9S
2 ,1
1 5 7
R=3.2 7.5 R=1.7
Sheet 2nd-3
RCR ENGINEERS, PLLC Structural Engineers
Project#
Subject
Project
29028 176`h AVE SE, Kent, WA 98042 (206) 295 9439
PAUL TRIEU Date 3-7-22
UPPER FLOOR / LOW ROOF FRAMING
B-13 L=17
RF TRIB = 9.5+2.5=12 FT
FL TRIB = 9 FT
WALL = 100PLF
W12X19
B-14 L=24
RF TRIB = 3+2=5 FT
FL TRIB = 2 FT
H-9=1.OD 1.45S
WALL = 100PLF
W 16X26
Sheet 2nd-4
4' MIN @ WALL
RF
RF H-9 SEE B-13 R= 3.8D 3.2L 2.7S
7
4" @ WALL 7 1 5 1
UNIF LOAD
COL 0 STUDS 19 5
R=4.8D+1.7L+3.8S=10.2 R=12.6
TRIB=18 FLR 12 RF
B-15 L= 6 FT
trib flr =9.5
TRIB RF = 9.5+3=12.5
3 1/2 X 7 PSL 2 JACKS STUDS
B-16 L=5
FLR TRIB = 17
FLR B-5 1.3D .72L
RF H-2 1.8D 2.6S
2-1 3/4 X 11 7/8 LVL
B-17 TRIB = 5FT
4X10 DF#2
B-18 L=6 TRIB =5+2=7
4X10 DF#2
B-19 L=10
4X10 DF#2
RF H-2
B-5
1 11 3
5
6 12
.56 2.6 1.1
B-17
.95+.5=1.0
RCR ENGINEERS, PLLC Structural Engineers
Project#
Subject
Project
29028 176`h AVE SE, Kent, WA 98042 (206) 295 9439
PAUL TRIEU Date 3-7-22
UPPER FLOOR / LOW ROOF FRAMING
H-3 L= 5.0
RFTRIB =2
FLR TRIB = 2
WALL = 100
2-2X6 DF#2
H-4 L= 16
LOW RF TRIB = 5
HIGH RF TRIB = 12
WALL = 100
5 1/8 X 15 GLB R= 6.6k
Sheet 2nd-5
H-5 L= 9.5
RF TRIB =2
P=.3 D 1.5 S
FLR TRIB = 5
WALL = 100
1.75� 1.75
2- 1 3/4 X 9 1/2 LVL
H-6 L= 3
9.5
3.3 3.3
RF TRIB =2+4=6
3 STUD MIN 3 STUD MIN
FLR TRIB = 2
WALL = 100
2-2X6 DF#2
H-7 L=3.0
FLR TRIB = 2
WALL = 50
2-2X6 DF#2
H-8 L= 3.5 VRFY EXIST
RF TRIB =6.5
FLR TRIB =5.5
WALL = 100
2-2X6 DF#2
H-9 L= 3.0 VRFY EXIST
RF TRIB =10
FLR TRIB =9
WALL = 100
2-2X6 DF#2
H-10 L=4.0 VRFY EXIST
RF TRIB =10
FLR TRIB =9
WALL = 100
2-2X8 DF#2
H-11 L=3.0
FLR TRIB =15
WALL = 100
2-2X8 DF#2
SEE B-17 1.1 D 1.6S
H-12 L=4.5 3.5
WALL = 50 4.5
2-2X8 DF#2
a r O R T G CM MEMBER REPORT PASSED
2ND FLR, Floor: Joist 3-1
1 piece(s) 11 7/8" T310 210 C@ 12" OC
Overall Length: 19' 7.00`
I; 1910.001,
1
❑i
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
533 @ 2.50"
1134 (2.25")
Passed (47%)
1.00
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
523 @ 3.50"
1655
Passed (32%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
2526 @ 9' 9.50"
3795
Passed (67%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.358 @ 9' 9.50"
0.479
Passed (L/643)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.492 @ 9' 9.50"
0.958
Passed (L/468)
1.0 D + 1.0 L (All Spans)
TJ-ProT" Rating
41
40
Passed
• Deflection criteria: LL (L/480) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser EdgeT" Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-ProT" Rating include: None.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Stud wall - SPF
3.50"
2.25"
1.75"
147
392
539
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.75"
147
392
539
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
4' 7.00" o/c
Bottom Edge (Lu)
19' 5.00" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
-Maximum allowable bracing intervals based on applied load.
Vertical Load
Location
Spacing
Dead
(0.90)
Floor Live
(1.00)
Comments
1 - Uniform (PSF)
0 to 19' 7.00"
12"
15.0
40.0
Default Load
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/6/2022 5:38:13 PM UTC
ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTEWEB'
2ND FLR, Floor: Joist 3-2 REV
1 piece(s) 11 7/8" TII@ 110 @ 16" OC
PASSED
F
C,verall Length: 17 1
i[,4j(tItl
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
925 @ 16' 10.50"
1041 (2.25")
Passed (89%)
1.00
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
911 @ 16' 9.50"
1560
Passed (58%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
2781 @ 8' 11.00"
3160
Passed (88%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.309 @ 8' 6.48"
0.417
Passed (L/647)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.470 @ 8' 7.83"
0.833
Passed (L/426)
1.0 D + 1.0 L (All Spans)
TJ-ProT"' Rating
41
40
Passed
• Deflection criteria: LL (L/480) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edger" Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-ProTm Rating include: None.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Factored
1 - Stud wall - SPF
3.50"
2.25"
1.75"
198
456
28
654
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.81"
477
456
306
1048
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
T 3.00" o/c
Bottom Edge (Lu)
16' 11.00" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Spacing
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
1 - Uniform (PSF)
0 to 17' 1.00"
16"
15.0
40.0
-
Default Load
2 - Point (PLF)
15' 6.00"
16"
250.0
-
250.0
WALL
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
8/12/2023 9:49:42 PM UTC
ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTEWEB'
LOW ROOF, Floor: Flush Beam J-2A
2 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam@ LVL
PASSED
Ad
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3238 @ 16' 11.00"
5950 (4.00")
Passed (54%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
2984 @ 15' 9.63"
9081
Passed (33%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Moment (Ft-Ibs)
8744 @ 8' 11.66"
17848
Passed (49%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.297 @ 8' 7.23"
0.416
Passed (L/672)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.476 @ 8' 8.55"
0.831
Passed (L/419)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/480) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Factored
1 - Hanger on 11 7/8" SPF beam
3.50"
Hangers
1.50"
702
1377
85
2079
See note 1
2 - Stud wall - SPF
5.25"
4.00"
2.18"
1536
1380
915
3257
1 1/4" Rim Board
• Kim board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
16' 10.00" o/c
Bottom Edge (Lu)
16' 10.00" o/c
-Maximum allowable bracing intervals based on applied load.
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
1 - Face Mount Hanger
HHUS48
3.00"
N/A
22-10d
8-10d
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
3.50" to 17' 1.50"
N/A
12.1
1 - Uniform (PSF)
0 to 17' 2.75" (Front)
4' 0.00"
15.0
40.0
-
Default Load
2 - Point (lb)
15' 6.00" (Front)
N/A
1000
-
1000
WALL
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
8/12/2023 9:57:23 PM UTC
ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTEWEB'
MEMBER REPORT
2ND FLR, Floor: Joist 3-3
1 piece(s) 11 7/8" T31@ 110 @ 16" OC
PASSED
0
Overall Length: 8' 10.71;
6' 0.00"
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
604 @ 5' 8.00"
2350 (5.25")
Passed (26%)
1.00
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
320 @ 6' 10.75"
1560
Passed (21%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
304 @ 3' 3.80"
3160
Passed (10%)
1.00
1.0 D + 1.0 L (Alt Spans)
Live Load Defl. (in)
0.010 @ 3' 6.63"
0.156
Passed (L/999+)
1.0 D + 1.0 L (Alt Spans)
Total Load Defl. (in)
0.009 @ 8' 10.75"
0.223
Passed (2L/999+)
1.0 D + 1.0 L (Alt Spans)
TJ-ProT" Rating
68
40
Passed
• Deflection criteria: LL (L/480) and TL (L/240).
• Overhang deflection criteria: LL (2L/480) and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser EdgeT" Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-ProT" Rating include: None.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Roof Live
Factored
1 - Hanger on 11 7/8" SPF beam
5.25"
Hanger'
1.75" / - z
54
189
-4
243
See note '
2 - Stud wall - SPF
5.50"
5.50"
3.50"
297
306
70
604
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
• z Required Bearing Length / Required Bearing Length with Web Stiffeners
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu) T 4.00" o/c
Bottom Edge (Lu) 74.00" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
-Maximum allowable bracing intervals based on applied load.
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Connector: Simpson Strong -Tie
Support
Model J1
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
1 - Face Mount Hanger
IUS1.81/11.88
2.00"
N/A
10-10dx1.5
2-Strong-Grip
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Vertical Loads
Location
Spacing
Dead
(0.90)
Floor Live
(1.00)
Roof Live
(non -snow: 1.25)
Comments
1 - Uniform (PSF)
0 to 8' 10.75"
16"
15.0
40.0
-
Default Load
2 - Point (PLF)
T 0.00"
16"
130.0
-
50.0
WALL
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
8/12/2023 9:39:19 PM UTC
ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 2
a FORTE rV GB MEMBER REPORT
2ND FLR, Floor: Joist 3-4
1 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam@ LVL @ 16" OC
PASSED
Overall Length: 8' 9.00"
rVI O
0
r
2' 0.00"
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2804 @ 6' 6.25"
4091 (5.50")
Passed (69%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
2194 @ 7' 8.88"
4541
Passed (48%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
-3264 @ 6' 6.25"
10673
Passed (31%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.043 @ 8' 9.00"
0.200
Passed (2L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.078 @ 8' 9.00"
0.223
Passed (2L/682)
1.0 D + 1.0 S (All Spans)
TJ-ProT" Rating
72
40
Passed
• Deflection criteria: LL (L/480) and TL (L/240).
• Overhang deflection criteria: LL (0.2") and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A 4% increase in the moment capacity has been added to account for repetitive member usage.
• -456 Ibs uplift at support located at 3.50". Strapping or other restraint may be required.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser EdgeTM Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-ProT" Rating include: None.
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Supports '
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Roof Live
Snow
Factored
1 - Hanger on 11 7/8" DF beam
3.50"
Hangers
1.50"
-171
182/-6
-16
-285
11/456
See note
2 - Stud wall - SPF
5.50"
5.50"
3.77"
1319
306
82
1485
2804
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
8' 6.00" o/c
Bottom Edge (Lu)
8' 6.00" o/c
-Maximum allowable bracing intervals based on applied load.
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
1 - Face Mount Hanger
HUS1.81/10
3.00"
N/A
30-10dx1.5
10-10d
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Vertical Loads
Location (Side)
Spacing
Dead
(0.90)
Floor Live
(1.00)
Roof Live
(non -snow: 1.25)
Snow
(1.15)
Comments
1 - Uniform (PSF)
0 to 8' 9.00"
16"
15.0
40.0
-
Default Load
2 - Point (PLF)
8' 0.00"
16"
130.0
-
50.0
WALL
3 - Point (lb)
8' 0.00"
N/A
800
-
1200
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
8/12/2023 9:38:00 PM UTC
ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 2
aFORTE'CM
LOW ROOF, Roof: Drop Beam B-1
1 piece(s) 3 1/8" x 12" 24F-V4 DF Glulam
PASSED
16' 6.00"
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2470 @ 2.00"
4648 (3.50")
Passed (53%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
2096 @ 1' 3.50"
7619
Passed (28%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
10139 @ 8' 6.50"
17250
Passed (59%)
1.15
1.0 D + 1.0 S (All Spans)
Neg Moment (Ft-Ibs)
-839 @ 8' 6.50"
18500
Passed (5%)
1.60
0.6 D + 0.6 W (All Spans)
Live Load Defl. (in)
0.383 @ 8' 6.50"
0.837
Passed (L/525)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.632 @ 8' 6.50"
1.117
Passed (L/318)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 16' 9.00".
• Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 16' 9.00".
• -204 Ibs uplift at support located at 2.00". Strapping or other restraint may be required.
• -204 Ibs uplift at support located at 16' 11.00". Strapping or other restraint may be required.
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Total
Available
Required
Dead
Snow
Wind
Total
Supports
Accessories
1 - Stud wall- SPF
3.50"
3.50"
1.86"
975
1495
1315
2470/
Blocking
1315
2 -Stud wall -SPF
3.50"
3.50"
1.86"
975
1495
-1315
2470/
Blocking
1315
1315
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
17' 1.00" o/c
Bottom Edge (Lu)
17' 1.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Snow
(1.15) L
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 17' 1.00"
N/A
9.1
1 - Uniform (PSF)
0 to 17' 1.00" (Front)
70.00"
15.0
25.0
-22.0
Default Load
Notes
0
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 0/12
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/1/2022 6:10:04 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
LOW ROOF, Roof: Drop Beam B-2
1 piece(s) 4 x 8 DF No.2
PASSED
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
940 @ 2.00"
5206 (3.50")
Passed (18%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
773 @ 10.75"
3502
Passed (22%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
2215 @ 5' 0.50"
3438
Passed (64%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.129 @ 5' 0.50"
0.488
Passed (L/910)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.213 @ 5' 0.50"
0.650
Passed (L/549)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Supports
Accessories
Total
Available
Required
Dead
Snow
Wind
Total
1 - Stud wall - SPF
3.50"
3.50"
1.50"
373
567
-499
499
Blocking
2 - Stud wall - SPF
3.50"
3.50"
1.50"
373
567
-499
9499
Blocking
• tsiocKing raneis are assumea to carry no ioaas appuea airectiy aoove mem ana the tuii ioaa is appiiea to the memoer Deing aesignea.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
10' 1.00" o/c
Bottom Edge (Lu)
10' 1.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 10' 1.00"
N/A
6.4
1 - Uniform (PSF)
0 to 10' 1.00" (Front)
4' 6.00"
15.0
25.0
-22.0
Default Load
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 0/12
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/6/2022 5:25:11 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
LOW ROOF, Roof: Drop Beam B-3
1 piece(s) 3 1/2" x 11 7/8" 1.55E TimberStrand@ LSL
PASSED
G✓erall Length: 13
1
�. 18' 6.00"
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1997 @ 0
2231 (1.50")
Passed (89%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1759 @ 1' 1.38"
9878
Passed (18%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
9360 @ 9' 4.50"
18346
Passed (51%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.479 @ 9' 4.50"
0.938
Passed (L/470)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.816 @ 9' 4.50"
1.250
Passed (L/276)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length
Loads to Supports (Ibs)
Total
Available
Required
Dead
Snow
Wind
Total
Supports
Accessories
1 - Stud wall - SPF
1.50"
1.50"
1.50"
825
1172
-1031
1997/
Blocking
1031
2 - Stud wall- SPF
1.50"
1.50"
1.50"
825
1172
-1031
1997/
Blocking
1031
• Blocking Panels are assumed to carry no Ioacl applied directly above them and the Lull load Is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
18' 9.00" o/c
Bottom Edge (Lu)
18' 9.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 18' 9.00"
N/A
13.0
1 - Uniform (PSF)
0 to 18' 9.00" (Front)
T 0.00"
15.0
25.0
-22.0
Default Load
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 0/12
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/6/2022 5:30:43 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Floor: Drop Beam B-4
1 piece(s) 5 1/8" x 15" 24F-V4 DF Glulam
PASSED
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
6447 @ 17' 7.46"
6447 (1.94")
Passed (100%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
5524 @ 16' 4.46"
15618
Passed (35%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
28133 @ 8' 10.73"
44034
Passed (64%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.312 @ 8' 10.73"
0.582
Passed (L/671)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.595 @ 8' 10.73"
0.873
Passed (L/352)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 17' 5.46".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
3.50"
3.02"
3123
3446
6569
Blocking
2 - Hanger on 15" OF beam
3.50"
Hangers
1.94"
3162
3495
6657
See note 1
• blocking Panels are assumed to carry no loads appueo oirectiy aoove tnem and the tun load is appueo to the memoer oemg oesigneo.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
177.00" o/c
Bottom Edge (Lu)
177.00" o/c
-Maximum allowable bracing intervals based on applied load.
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
2 - Face Mount Hanger
HGUS5.25/10
4.00"
N/A
46-10d
16-10d
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 17' 7.46"
N/A
18.7
1 - Uniform (PSF)
0 to 17' 10.96" (Front)
10' 6.00"
15.0
25.0
HIGH RF
2 - Uniform (PSF)
0 to 17' 10.96" (Front)
5' 0.00"
15.0
25.0
LOW ROOF
3 - Uniform (PLF)
0 to 17' 10.96" (Front)
N/A
100.0
WALL
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/6/2022 6:00:50 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 2
aFORTE'CM
2ND FLR, Floor: Drop Beam B-5
1 piece(s) 3 1/2" x 11 7/8" 1.55E TimberStrand@ LSL
PASSED
I
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1946 @ 17' 7.46"
4725 (1.50")
Passed (41%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
1726 @ 16' 7.59"
8590
Passed (20%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
8493 @ 8' 10.73"
15953
Passed (53%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.232 @ 8' 10.73"
0.582
Passed (L/904)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.646 @ 8' 10.73"
0.873
Passed (L/324)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Stud wall - SPF
3.50"
3.50"
1.50"
1272
712
1984
Blocking
2 - Hanger on 11 7/8" DF beam
3.50"
Hanger'
1.50"
1286
722
2008
See note'
• blocking Panels are assumed to carry no loads applied directly above them and the tuil load Is applied to the member Deng designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
17' 7.00" o/c
Bottom Edge (Lu)
IT 7.00" o/c
-Maximum allowable bracing intervals based on applied load.
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
2 - Face Mount Hanger
LUS414
2.00"
N/A
10-16d
6-16d
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Comments
0 - Self Weight (PLF)
0 to 17' 7.46"
N/A
13.0
1 - Uniform (PSF)
0 to 17' 10.96" (Front)
2' 0.00"
15.0
40.0
FLOOR
2 - Uniform (PLF)
0 to 17' 10.96" (Front)
N/A
100.0
-
RAIL
Weyerhaeuser Notes
Veyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Veyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-138-,
nd/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
iww.weyerhaeuser.com/woodproducts/document-library.
'he product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/7/2022 10:13:55 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Floor: Drop Beam B-6
1 piece(s) 3 1/8" x 13 1/2" 24F-V4 DF Glulam
PASSED
I
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
5070 @ 2.00"
6836 (3.50")
Passed (74%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
3923 @ 1' 5.00"
7453
Passed (53%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
16949 @ 7' 3.50"
18984
Passed (89%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.296 @ 7' 3.50"
0.475
Passed (L/578)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.559 @ 7' 3.50"
0.712
Passed (L/306)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 14' 3.00".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Stu�wall-
3.50"
3.50"
2.60"
2390
2479
1094
5963
Blocking
2 - Stud wall - DF
3.50"
3.50"
2.60"
2390
2479
1094
5963
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
13' 6.00" o/c
Bottom Edge (Lu)
14' 7.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 14' 7.00"
N/A
10.3
1 - Uniform (PSF)
0 to 14' 7.00" (Front)
8' 6.00"
15.0
40.0
-
2ND FLR
2 - Uniform (PSF)
0 to 14' 7.00" (Front)
60.00"
15.0
25.0
RF
3 - Uniform (PLF)
0 to 14' 7.00" (Front)
N/A
100.0
WALL
Notes
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/7/2022 7:34:04 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Floor: Flush Beam B-7
1 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand@ LSL
PASSED
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1615 @ 2.00"
1673 (2.25")
Passed (97%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
1203 @ 7' 3.63"
4295
Passed (28%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
3231 @ 4' 2.75"
7977
Passed (41%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.089 @ 4' 2.75"
0.203
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.125 @ 4' 2.75"
0.406
Passed (L/783)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/480) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Stud wall - SPF
3.50"
2.25"
2.17"
471
1184
1655
1 1/4" Rim Board
2 - Hanger on 11 7/8" SPF beam
3.50"
Hanger'
1.50"
484
1219
1703
See note '
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
8' 2.00" o/c
Bottom Edge (Lu)
8' 2.00" o/c
-Maximum allowable bracing intervals based on applied load.
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
2 - Face Mount Hanger
U14
2.00"
N/A
14-16d
6-10dx1.5
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Comments
0 - Self Weight (PLF)
1.25" to 8' 3.50"
N/A
6.5
1 - Uniform (PSF)
0 to 8' 7.00" (Front)
70.00"
15.0
40.0
Default Load
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/7/2022 10:34:17 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Floor: Drop Beam B-8
2 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam@ LVL
PASSED
I
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2457 @ 17' 7.46"
3938 (1.50")
Passed (62%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
2336 @ 16' 7.59"
7897
Passed (30%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
13593 @ 11' 0.00"
17848
Passed (76%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.408 @ 9' 2.85"
0.582
Passed (L/513)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.751 @ 9' 0.82"
0.873
Passed (L/279)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Stud wall - SPF
3.50"
3.50"
1.68"
1328
1167
2495
Blocking
2 - Hanger on 11 7/8" DF beam
3.50"
Hanger'
1.50"
1023
1466
2489
See note'
• blocking Panels are assumed to carry no loads applied directly above them and the tuil load Is applied to the member Deng designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
9' 3.00" o/c
Bottom Edge (Lu)
17' 7.00" o/c
-Maximum allowable bracing intervals based on applied load.
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
2 - Face Mount Hanger
HHUS48
3.00"
N/A
22-10d
8-10d
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Comments
0 - Self Weight (PLF)
0 to 17' 7.46"
N/A
12.1
1 - Uniform (PSF)
0 to 17' 10.96" (Front)
2' 0.00"
15.0
40.0
FLOOR
2 - Uniform (PLF)
0 to 11' 0.00" (Front)
N/A
100.0
-
WALL
3 - Point (lb)
11' 0.00" (Front)
N/A
500
1200
PT LD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/7/2022 10:40:30 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Wall: Header B-9
2 piece(s) 2 x 6 DF No.2
PASSED
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
588 @ 0
2813 (1.50")
Passed (21%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
458 @ 7.00"
1980
Passed (23%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
772 @ 2' 7.50"
1475
Passed (52%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.041 @ 2' 7.50"
0.175
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.058 @ 2' 7.50"
0.262
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Trimmer - SPF
1.50"
1.50"
1.50"
168
420
588
None
2 - Trimmer - SPF
1.50"
1.50"
1 1.50"
168
420
588
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
5' 3.00" o/c
Bottom Edge (Lu)
5' 3.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Comments
0 - Self Weight (PLF)
0 to 5' 3.00"
N/A
4.2
1 - Uniform (PSF)
0 to 5' 3.00"
4' 0.00"
15.0
40.0
2ND FLR
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/7/2022 8:25:04 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Floor: Flush Beam B-10
1 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand@ LSL
PASSED
Overall Length: 12' 10.50
■
l 60.00"
0 0
6 0.W
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3335 @ 6' 5.25"
3828 (3.50")
Passed (87%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
1495 @ 5' 3.63"
4295
Passed (35%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
2062 @ 2' 9.55"
7977
Passed (26%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.033 @ 3' 1.24"
0.157
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (Alt Spans)
Total Load Defl. (in)
0.060 @ T 0.57"
0.314
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (Alt Spans)
• Deflection criteria: LL (L/480) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Stud wall - DF
3.50"
2.25"
1.61"
854
813
490
2157
1 1/4" Rim Board
2 - Beam - DF
3.50"
3.50"
3.05"
1824
975
1039
3838
None
3 - Stud wall - DF
3.50"
2.25"
1.50"
311
-108
174
4108
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
12' 8.00" o/c
Bottom Edge (Lu)
12' 8.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
1.25" to 12' 9.25"
N/A
6.5
1 - Uniform (PSF)
0 to 6' 0.00" (Front)
70.00"
15.0
-
25.0
W1 RF
2 - Uniform (PSF)
0 to 6' 0.00" (Front)
70.00"
15.0
40.0
-
W 1 FL
3 - Uniform (PLF)
0 to 12' 10.50" (Front)
N/A
100.0
-
-
WALL
4 - Uniform (PSF)
6' 0.00" to 12' 0.00" (Front)
4' 0.00"
15.0
25.0
W2 RF
Notes
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/7/2022 8:32:19 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Floor: Flush Beam B-11
1 piece(s) 3 1/2" x 11 7/8" 1.55E TimberStrand@ LSL
PASSED
r
i
� r
2' 0.00"
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
7050 @ IT 0.50"
18900 (6.00")
Passed (37%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
3747 @ 13' 3.38"
9878
Passed (38%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Moment (Ft-Ibs)
-7532 @ 12' 0.50"
18346
Passed (41%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)
0.081 @ 14' 3.50"
0.200
Passed (2L/668)
1.0 D + 0.75 L + 0.75 S (Alt Spans)
Total Load Defl. (in)
0.111 @ 14' 3.50"
0.225
Passed (2L/484)
1.0 D + 0.75 L + 0.75 S (Alt Spans)
• Deflection criteria: LL (L/480) and TL (L/240).
• Overhang deflection criteria: LL (2L/0.2") and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 -Stud wall - DF
3.50"
3.50"
1.50"
996
488/-215
670
2215
Blocking
2 - Column - steel
6.00"
6.00"
2.24"
3868
2070
2172
8110
Blocking
• owcKing vaneis are assumes to carry no ioaas appuea aireary aoove tnem ano the nu ioaa is appuea to me memoer Deing Designeo.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
14' 4.00" o/c
Bottom Edge (Lu)
14' 4.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 14' 3.50"
N/A
13.0
--
--
1 - Uniform (PSF)
0 to 14' 3.50" (Front)
2' 0.00"
15.0
40.0
-
FLR
2 - Uniform (PSF)
0 to 14' 0.00" (Front)
T 0.00"
15.0
-
25.0
RF
3 - Uniform (PLF)
0 to 14' 0.00" (Front)
N/A
100.0
-
-
WALL
4 - Point (lb)
14' 0.00" (Front)
N/A
1800
1200
1000
0
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/1/2022 7:15:34 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Floor: Flush Beam B-12
1 piece(s) 3 1/2" x 11 7/8" 1.55E TimberStrand® LSL
PASSED
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2838 @ 2.00"
7656 (3.50")
Passed (37%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
2117 @ 1' 3.38"
9878
Passed (21%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
6690 @ 5' 0.50"
18346
Passed (36%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.082 @ 5' 0.50"
0.244
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.175 @ 5' 0.50"
0.488
Passed (L/668)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/480) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Stud wall - DF
3.50"
3.50"
1.50"
1515
403
1323
3241
Blocking
2 - Stud wall - DF
3.50"
3.50"
1.50"
1515
403
1323
3241
Blocking
• blocking Panels are assumed to carry no loads applied directly above them and the tull load Is applied to the member Dung designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
10' 1.00" o/c
Bottom Edge (Lu)
10' 1.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 10' 1.00"
N/A
13.0
1 - Uniform (PSF)
0 to 10' 1.00" (Front)
2' 0.00"
15.0
40.0
-
FLR
2 - Uniform (PSF)
0 to 10' 1.00" (Front)
10' 6.00"
15.0
-
25.0
RF
3 - Uniform (PLF)
0 to 10' 1.00" (Front)
N/A
100.0
-
-
WALL
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/8/2022 11:08:19 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Floor: Drop Beam B-13
1 piece(s) 5 1/8" x 15" 24F-V4 DF Glulam
PASSED
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
17
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
7952 @ 3.50"
7952 (2.39")
Passed (100%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
6791 @ 1' 6.50"
15618
Passed (43%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Pos Moment (Ft-Ibs)
34044 @ 8' 10.25"
44119
Passed (77%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)
0.369 @ 8' 10.25"
0.571
Passed (L/557)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.693 @ 8' 10.25"
0.856
Passed (L/297)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 17' 1.50".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Hanger on 15" SPF beam
3.50"
Hangers
2.39"
3834
3188
2656
9678
See note '
2 - Stud wall - SPF
5.50"
5.50"
3.79"
3858
3203
2669
9730
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
17' 6.00" o/c
Bottom Edge (Lu)
176.00" o/c
-Maximum allowable bracing intervals based on applied load.
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
1 - Face Mount Hanger
HGUS5.25/12
4.00"
N/A
56-10d
20-10d
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
3.50" to 17' 9.00"
N/A
18.7
1 - Uniform (PSF)
0 to 17' 9.00" (Front)
12' 0.00"
15.0
-
25.0
RF
2 - Uniform (PSF)
0 to 17' 9.00" (Front)
910.001,
15.0
40.0
-
FLR
3 - Uniform (PLF)
0 to 17' 9.00" (Front)
N/A
100.0
-
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/7/2022 11:24:08 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 2
aFORTE'CM
2ND FLR, Floor: Drop Beam B-14
1 piece(s) 5 1/8" x 19 1/2" 24F-V4 DF Glulam
PASSED
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
17
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
8784 @ 3.50"
8784 (2.64")
Passed (100%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
10796 @ 22' 8.00"
20304
Passed (53%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Pos Moment (Ft-Ibs)
66394 @ 12' 6.24"
70183
Passed (95%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)
0.591 @ 12' 8.63"
0.804
Passed (L/490)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
1.233 @ 12' 7.88"
1.206
Passed (L/235)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 0.94 that was calculated using length L = 24' 1.50".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Hanger on 19 1/2" SPF beam
3.50"
Hangers
2.64"
4791
1658
3806
10255
See note '
2 - Stud wall - SPF
5.50"
5.50"
4.98"
5498
3062
4069
12629
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
13' 0.00" o/c
Bottom Edge (Lu)
24' 6.00" o/c
-Maximum allowable bracing intervals based on applied load.
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Connector: Simpson Strong -Tie
Support
1
1 Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
1 - Face Mount Hanger
HGU5.25-SDS H=19.5
5.25"
N/A
36-SDS25212
24-SDS25212
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
3.50" to 24' 9.00"
N/A
24.3
1 - Uniform (PSF)
0 to 19' 0.00" (Front)
5' 0.00"
15.0
-
25.0
RF
2 - Uniform (PSF)
0 to 19' 0.00" (Front)
2' 0.00"
15.0
40.0
-
FLR
3 - Uniform (PLF)
0 to 19' 0.00" (Front)
N/A
100.0
-
-
WALL
4 - Point (lb)
19' 0.00" (Front)
N/A
3800
3200
2700
PT LD
5 - Point (lb)
7' 0.00" (Front)
N/A
1000
-
1400
H-5 LEFT
6 - Point (lb)
12' 0.00" (Front)
N/A
1000
1400
H-5 RT
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/7/2022 8:49:41 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 2
aFORTE'CM
2ND FLR, Floor: Drop Beam B-15
1 piece(s) 3 1/2" x 7" 1.8E Parallam@ PSL
PASSED
1
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3110 @ 1.50"
5723 (3.00")
Passed (54%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
2313 @ 10.00"
4320
Passed (54%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Moment (Ft-Ibs)
4673 @ 3' 3.00"
7270
Passed (64%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)
0.112 @ 3' 3.00"
0.208
Passed (L/668)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.207 @ 3' 3.00"
0.313
Passed (L/363)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Stud wall - DF
3.00"
3.00"
1.63"
1422
1235
1016
3673
None
2 - Stud wall - OF
3.00"
3.00"
1.63"
1422
1235
1016
3673
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the tull load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
66.00" o/c
Bottom Edge (Lu)
6' 6.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 6' 6.00"
N/A
7.6
1 - Uniform (PSF)
0 to 6' 6.00" (Front)
12' 6.00"
15.0
-
25.0
ROOF
2 - Uniform (PSF)
0 to 6' 6.00" (Front)
9' 6.00"
15.0
40.0
-
FLR
3 - Uniform (PLF)
0 to 6' 6.00" (Front)
N/A
100.0
-
-
WALL
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/13/2022 3:06:05 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Floor: Drop Beam B-16
2 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam@ LVL
PASSED
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3847 @ 5' 6.00"
6694 (4.50")
Passed (57%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
4773 @ 1' 4.38"
9081
Passed (53%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Moment (Ft-Ibs)
8025 @ 2' 0.00"
20525
Passed (39%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)
0.029 @ 2' 9.20"
0.175
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.056 @ 2' 8.94"
0.262
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Column - SPF
4.50"
4.50"
2.57"
3282
2572
1733
7587
Blocking
2 - Stud wall- SPF
4.50"
4.50"
2.59"
1654
2058
867
4579
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the Tull load Is applied to the member bung designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
5' 9.00" o/c
Bottom Edge (Lu)
5' 9.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 5' 9.00"
N/A
12.1
1 - Uniform (PSF)
0 to 5' 9.00" (Front)
17' 0.00"
15.0
40.0
Default Load
2 - Point (lb)
1' 0.00" (Front)
N/A
1300
720
B-5
3 - Point (Ib)
2' 0.00" (Front)
N/A
2100
2600
H-2
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/7/2022 8:57:25 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Roof: Drop Beam B-17
1 piece(s) 4 x 10 DF No.2
PASSED
f
6' 0.00'
121
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2639 @ 6' 5.25"
5206 (3.50")
Passed (51%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1326 @ 7' 4.25"
4468
Passed (30%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
-2940 @ 6' 5.25"
5166
Passed (57%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.101 @ 13' 1.23"
0.614
Passed (L/999+)
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.165 @ 13' 1.48"
0.818
Passed (L/894)
1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• -204 Ibs uplift at support located at 6' 5.25". Strapping or other restraint may be required.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Total
Available
Required
Dead
Snow
Wind
Total
Supports
Accessories
1 -Stud wall -SPF
3.50"
3.50"
1.50"
87
255/-58
218/-334
Blocking
392
2 - Stud wall - SPF
3.50"
3.50"
1.77"
1054
1584
-1394
2638/
Blocking
1394
3 - Stud wall - SPF
3.50"
3.50"
1.50"
429
652
15/-582
1
Blocking
82/
• ttiocKmg Faneis are assumea to carry no ioaas appuea airectiy above tnem ana the tuii ioaa is appuea to the memoer Deing aesignea.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
18' 11.00" o/c
Bottom Edge (Lu)
18' 11.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to IS' 10.50"
N/A
8.2
1 - Uniform (PSF)
0 to 18' 10.50" (Front)
5' 0.00"
15.0
25.0
-22.0
Default Load
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 0/12
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/wo(>dproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/7/2022 5:29:39 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Roof: Drop Beam B-18
1 piece(s) 4 x 10 DF No.2
PASSED
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
949 @ 2.00"
5206 (3.50")
Passed (18%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
642 @ 1' 0.75"
4468
Passed (14%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
1407 @ 3' 3.50"
5166
Passed (27%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.016 @ 3' 3.50"
0.313
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.027 @ 3' 3.50"
0.417
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Supports
Accessories
Total
Available
Required
Dead
Snow
Wind
Total
1 - Stud wall - SPF
3.50"
3.50"
1.50"
373
576
-507
Blocking
50/
2 - Stud wall - SPF
3.50"
3.50"
1.50"
373
576
-507
9507
Blocking
• tsiocKing raneis are assumea to carry no ioaas appiiea airectiy aoove mem ana the tuii ioaa is appiiea to the memoer Deing aesignea.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
6' 7.00" o/c
Bottom Edge (Lu)
67.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 6' 7.00"
N/A
8.2
1 - Uniform (PSF)
0 to 6' 7.00" (Front)
70.00"
15.0
25.0
-22.0
Default Load
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 0/12
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/7/2022 9:01:29 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
LOW ROOF, Wall: Header H-1
2 piece(s) 2 x 6 DF No.2
PASSED
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
C
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
383 @ 0
2813 (1.50")
Passed (14%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
264 @ 7.00"
2277
Passed (12%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
359 @ 1' 10.50"
1696
Passed (21%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.008 @ 1' 10.50"
0.125
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.014 @ 1' 10.50"
0.188
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Supports
Accessories
Total
Available
Required
Dead
Snow
Wind
Total
1 - Trimmer - SPF
1.50"
1.50"
1.50"
148
234
-206
3 2/
None
06
2 - Trimmer - SPF
1.50"
1.50"
1.50"
148
234
-206
3 2/
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
3' 9.00" o/c
Bottom Edge (Lu)
3' 9.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 3' 9.00"
N/A
4.2
1 - Uniform (PSF)
0 to 3' 9.00"
5' 0.00"
5.0
25.0
-22.0
Default Load
2 - Uniform (PLF)
0 to 3' 9.00"
N/A
50.0
-
-
WALL
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/6/2022 5:27:48 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
LOW ROOF, Wall: Header H-2
1 piece(s) 4 x 6 DF No.2
PASSED
- 1 0
3' 6.00"
Fill
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
8488 @ 3.00"
9844 (4.50")
Passed (86%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
200 @ 10.00"
2657
Passed (8%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
272 @ 2' 1.50"
1979
Passed (14%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.007 @ 2' 1.50"
0.125
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.009 @ 2' 1.50"
0.188
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Bearing Length
Loads to Supports (Ibs)
Supports
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Wind
Total
1 -Trimmer - DF
4.50"
4.50"
3.88"
3863
3200
2966
-234
10234/
None
2 - Trimmer - DF
1.50"
1.50"
1.50"
56
-
234
-206
2 0/
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
4' 0.00" o/c
Bottom Edge (Lu)
4' 0.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Wind
(1.60)
comments
0 - Self Weight (PLF)
0 to 4' 0.00"
N/A
4.9
1 - Uniform (PSF)
0 to 4' 0.00"
5' 0.00"
5.0
-
25.0
-22.0
Default Load
2 - Point (lb)
0
N/A
3800
3200
2700
-
WALL
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/1/2022 6:23:51 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Wall: Header H-3
2 piece(s) 2 x 6 DF No.2
PASSED
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
687 @ 0
2813 (1.50")
Passed (24%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
499 @ 7.00"
1980
Passed (25%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
841 @ 2' 7.50"
1475
Passed (57%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.025 @ 2' 7.50"
0.175
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.067 @ 2' 7.50"
0.262
Passed (L/937)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Trimmer - SPF
1.50"
1.50"
1.50"
431
210
131
772
None
2 - Trimmer - SPF
1.50"
1.50"
1 1.50"
431
210
131
772
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
5' 3.00" o/c
Bottom Edge (Lu)
5' 3.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 5' 3.00"
N/A
4.2
1 - Uniform (PSF)
0 to 5' 3.00"
2' 0.00"
15.0
-
25.0
RF
2 - Uniform (PSF)
0 to 5' 3.00"
2' 0.00"
15.0
40.0
-
FLR
3 - Uniform (PLF)
0 to 5' 3.00"
N/A
100.0
-
-
WALL
Notes
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/7/2022 11:41:07 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Wall: Header H-4
1 piece(s) 5 1/8" x 15" 24F-V4 DF Glulam
PASSED
(, 16' 0.00"
f
o a
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
6589 @ 1.50"
9994 (3.00")
Passed (66%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
5391 @ 1' 6.00"
15618
Passed (35%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
26363 @ 8' 3.00"
44203
Passed (60%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.257 @ 8' 3.00"
0.542
Passed (L/759)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.483 @ 8' 3.00"
0.813
Passed (L/404)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 16' 3.00".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Supports _
Accessories
Total
Available
Required
Dead
Snow
Wind
Total
1 -Trimmer -SPF
3.00"
3.00"
1.98"
3083
3506
-2178
6589/
None
2178
2178
2 - Trimmer - SPF
3.00"
3.00"
1.98"
3083
3506
-2178
6589/
None
one
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
166.00" o/c
Bottom Edge (Lu)
166.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Snow
(1.15)
Wind
(1.60)
Comments
0 - Self Weight (PLF)
0 to 16' 6.00"
N/A
18.7
--
--
1 - Uniform (PSF)
0 to 16' 6.00"
T 0.00"
15.0
25.0
-
LOW RF
2 - Uniform (PSF)
0 to 166.00"
12' 0.00"
15.0
25.0
-22.0
HIGH RF
3 - Uniform (PLF)
0 to 166.00"
N/A
100.0
-
-
WALL
0
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/1/2022 6:33:24 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTEWEB'
2ND FLR, Wall: Header H-5 REV
2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
PASSED
C
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3359 @ 10' 0.00"
7613 (3.00")
Passed (44%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
3100 @ 1' 2.00"
7902
Passed (39%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Moment (Ft-Ibs)
7254 @ 5' 3.89"
11985
Passed (61%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)
0.215 @ 5' 1.95"
0.325
Passed (L/544)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.368 @ 5' 1.85"
0.488
Passed (L/318)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Factored
1 - Trimmer - SPF
4.50"
4.50"
1.50"
1421
1025
1841
3570
None
2 - Trimmer - SPF
3.00"
3.00"
1.50"
1360
1000
1665
3359
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
10' 2.00" o/c
Bottom Edge (Lu)
10' 2.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 10' 1.50"
N/A
10.4
1 - Uniform (PSF)
0 to 10' 1.50"
2' 0.00"
15.0
-
25.0
RF
2 - Uniform (PSF)
0 to 10' 1.50"
5' 0.00"
15.0
40.0
-
FLR
3 - Uniform (PLF)
0 to 10, 1.50"
N/A
100.0
-
-
WALL
4 - Point (lb)
1' 8.40"
N/A
300
1500
P
5 - Point (lb)
810.001,
N/A
300
1500
P
0
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
8/12/2023 10:20:37 PM UTC
ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, 7Wall: Header H-5
2 piece(s) 2 x 6 DF No.2
PASSED
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
267 @ 0
2813 (1.50")
Passed (9%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
171 @ 7.00"
1980
Passed (9%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
217 @ 1' 7.50"
1475
Passed (15%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.003 @ 1' 7.50"
0.108
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.006 @ 1' 7.50"
0.162
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Trimmer - SPF
1.50"
1.50"
1.50"
137
130
267
None
2 - Trimmer - SPF
1.50"
1.50"
1 1.50"
137
130
267
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
T 3.00" o/c
Bottom Edge (Lu)
T 3.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Comments
0 - Self Weight (PLF)
0 to 3' 3.00"
N/A
4.2
1 - Uniform (PSF)
0 to 3' 3.00"
2' 0.00"
15.0
40.0
FLR
2 - Uniform (PLF)
0 to 3' 3.00"
N/A
50.0
-
WALL
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/7/2022 11:53:16 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Wall: Header H-6
2 piece(s) 2 x 6 DF No.2
PASSED
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
645 @ 0
2813 (1.50")
Passed (23%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
413 @ 7.00"
2277
Passed (18%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Moment (Ft-Ibs)
524 @ 1' 7.50"
1696
Passed (31%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)
0.007 @ 1' 7.50"
0.108
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.015 @ 1' 7.50"
0.162
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Trimmer - SPF
1.50"
1.50"
1.50"
364
130
244
738
None
2 - Trimmer - SPF
1.50"
1.50"
1 1.50"
364
130
244
738
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
T 3.00" o/c
Bottom Edge (Lu)
T 3.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 3' 3.00"
N/A
4.2
1 - Uniform (PSF)
0 to 3' 3.00"
60.00"
15.0
-
25.0
RF
2 - Uniform (PSF)
0 to 3' 3.00"
2' 0.00"
15.0
40.0
-
FLR
3 - Uniform (PLF)
0 to 3' 3.00"
N/A
100.0
-
-
WALL
Notes
0
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/8/2022 1:22:12 AM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Wall: Header H-7
2 piece(s) 2 x 6 DF No.2
PASSED
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
267 @ 0
2813 (1.50")
Passed (9%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
171 @ 7.00"
1980
Passed (9%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
217 @ 1' 7.50"
1475
Passed (15%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.003 @ 1' 7.50"
0.108
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.006 @ 1' 7.50"
0.162
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Trimmer - SPF
1.50"
1.50"
1.50"
137
130
267
None
2 - Trimmer - SPF
1.50"
1.50"
1 1.50"
137
130
267
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
T 3.00" o/c
Bottom Edge (Lu)
T 3.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Comments
0 - Self Weight (PLF)
0 to 3' 3.00"
N/A
4.2
1 - Uniform (PSF)
0 to 3' 3.00"
2' 0.00"
15.0
40.0
FLR
2 - Uniform (PLF)
0 to 3' 3.00"
N/A
50.0
-
WALL
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/7/2022 11:53:16 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Wall: Header H-8
2 piece(s) 2 x 6 DF No.2
PASSED
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
C
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1071 @ 0
2813 (1.50")
Passed (38%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
651 @ 7.00"
1980
Passed (33%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
886 @ 1' 10.50"
1475
Passed (60%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.019 @ 1' 10.50"
0.125
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.038 @ 1' 10.50"
0.188
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Trimmer - SPF
1.50"
1.50"
1.50"
533
413
305
1251
None
2 - Trimmer - SPF
1.50"
1.50"
1 1.50"
533
413
305
1251
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
T 9.00" o/c
Bottom Edge (Lu)
T 9.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 3' 9.00"
N/A
4.2
1 - Uniform (PSF)
0 to 3' 9.00"
6' 6.00"
15.0
-
25.0
RF
2 - Uniform (PSF)
0 to 3' 9.00"
5' 6.00"
15.0
40.0
-
FLR
3 - Uniform (PLF)
0 to 3' 9.00"
N/A
100.0
-
-
WALL
Notes
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/8/2022 1:23:39 AM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Wall: Header H-9
2 piece(s) 2 x 6 DF No.2
PASSED
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1412 @ 0
2813 (1.50")
Passed (50%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
809 @ 7.00"
1980
Passed (41%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
1025 @ 1' 7.50"
1475
Passed (70%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.018 @ 1' 7.50"
0.108
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.033 @ 1' 7.50"
0.162
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Trimmer - SPF
1.50"
1.50"
1.50"
645
618
406
1669
None
2 - Trimmer - SPF
1.50"
1.50"
1 1.50"
645
618
406
1669
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
T 3.00" o/c
Bottom Edge (Lu)
T 3.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 3' 3.00"
N/A
4.2
1 - Uniform (PSF)
0 to 3' 3.00"
1010.001,
15.0
-
25.0
RF
2 - Uniform (PSF)
0 to 3' 3.00"
9' 6.00"
15.0
40.0
-
FLR
3 - Uniform (PLF)
0 to 3' 3.00"
N/A
100.0
-
-
WALL
Notes
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/8/2022 1:28:51 AM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Wall: Header H-10
2 piece(s) 2 x 8 DF No.2
PASSED
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1850 @ 0
2813 (1.50")
Passed (66%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
1086 @ 8.75"
2610
Passed (42%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
1757 @ 2' 1.50"
2365
Passed (74%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.023 @ 2' 1.50"
0.142
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.042 @ 2' 1.50"
0.213
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Trimmer - SPF
1.50"
1.50"
1.50"
846
808
531
2185
None
2 - Trimmer - SPF
1.50"
1.50"
1 1.50"
846
808
531
2185
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
4' 3.00" o/c
Bottom Edge (Lu)
4' 3.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 4' 3.00"
N/A
5.5
1 - Uniform (PSF)
0 to 4' 3.00"
1010.001,
15.0
-
25.0
RF
2 - Uniform (PSF)
0 to 4' 3.00"
9' 6.00"
15.0
40.0
-
FLR
3 - Uniform (PLF)
0 to 4' 3.00"
N/A
100.0
-
-
WALL
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/8/2022 1:29:52 AM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Wall: Header H-11
2 piece(s) 2 x 8 DF No.2
PASSED
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1512 @ 0
2813 (1.50")
Passed (54%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
834 @ 8.75"
2610
Passed (32%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
1229 @ 1' 7.50"
2365
Passed (52%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.010 @ 1' 7.50"
0.108
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.015 @ 1' 7.50"
0.162
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Trimmer - SPF
1.50"
1.50"
1.50"
537
975
1512
None
2 - Trimmer - SPF
1.50"
1.50"
1 1.50"
537
975
1512
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
T 3.00" o/c
Bottom Edge (Lu)
T 3.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Comments
0 - Self Weight (PLF)
0 to 3' 3.00"
N/A
5.5
1 - Uniform (PSF)
0 to 3' 3.00"
1510.001,
15.0
40.0
Default Load
2 - Uniform (PLF)
0 to 3' 3.00"
N/A
100.0
-
WALL
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/1/2022 6:42:58 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
2ND FLR, Wall: Header H-12
2 piece(s) 2 x 8 DF No.2
PASSED
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
C
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2263 @ 0
2813 (1.50")
Passed (80%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
2223 @ 8.75"
3002
Passed (74%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
2236 @ 1' 0.00"
2720
Passed (82%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.025 @ 2' 1.20"
0.158
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.045 @ 2' 1.45"
0.237
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Trimmer - SPF
1.50"
1.50"
1.50"
1000
1263
2263
None
2 - Trimmer - SPF
1.50"
1.50"
1 1.50"
363
337
700
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
4' 9.00" o/c
Bottom Edge (Lu)
4' 9.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 4' 9.00"
N/A
5.5
1 - Uniform (PLF)
0 to 4' 9.00"
N/A
50.0
-
WALL
2 - Point (lb)
110.001,
N/A
1100
1600
B-17
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/7/2022 5:32:42 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
RCR ENGINEERS. PLLC Structural EnLyineers
29028 176r" AVE SE, Kent, WA 98042 (206) 295 9439
Project# Project PAUL & NANCY TRIEU Date 3-1-2022
Subject MAIN LEVEL Sheet MAIN-1
DL=15
LL=40 / 60 DECKS
B-7
s
�
J-1 2X8 DF#2 @ 12"
t
J-2 2X8 DF#2 @ 16"
-2 EX
H- EX HD B-1 2- 1 3/4 X 9 1/4 LVL
4
`
H-1 ---�� B-2 2- 1 3/4 X 9 1/4 LVL
i11 B-3 5 1/8 X 12 GLB
w B-4 5 1/8 X 13 1/2 GLIB
J-1 B-5 2- 1 3/4 X 9 1/4 LVL
B-6 3-2X8 DF#2
i i i EX B-7 4X12 DF#2
N
00
_ _-_ -_ _ _, EX i H-1 2-2X8 DF#2
X H-2 2- 1 3/4 X 9 1/4 LVL
w
B-1 X v ��
w m ��
i
�o 0
II
�.:
EX co I
-7
m I I
II
. EX SOG
?
?
i
II
II
Ln
EX
F.8
o I
I
❑ F.9
II
CD
•
H
r
i
K
RCR ENGINEERS. PLLC Structural Enizineers
29028 1761h AVE SE, Kent, WA 98042 (206) 295 9439
Project# Project PAUL TRIEU Date 3-9-22
Subject MAIN FLOOR Sheet MAIN-2
DL=15
LL=40 / 60 DECKS RF TRTIB = 7FT
2ND FLR TRIB = 6 FT
WALL = 150plf
J-1
2X8 DF#2 @ 12" 1.0 10
R 0.48D
0.65L
0.20S
J-2 L= 7 FT LL=60 DECK
2X8 DF#2 @ 16"
RB-1 .75D 1.2S
B-1 TRIB RF = 4 FT 4.33
TRIB FLR = 2+2=4 1. 5.33
WALL=100PLF R=1.1 D .64L .68S R=1.2D .5L 1.2S
2- 1 3/4 X 9 1/4 LVL
B-1 1.1 D .64L .68S
B-2
2- 1 3/4 X 9 1/4 LVL 0 SEE J-1 REACTION
2.5 t 8
WALL
6.8k
RB-5 B-1
B-3L=11 FT RFTRIB =4FT 3.3D4.9S� 4 3
2ND TRIB = 2.5 FT 11 17
MAIN TRIB = 2.5 FT FOR 8 FT = 5 FT FOR 3 FT
WALL = 150 plf OVER 8FT R=10.0 R=7.1
51/8X12GLIB
B-4 MAIN TRIB = 2 FT + 100 plf WALL
P1=H-2 RF =3.4D 4.8S @3FT
P2= B-5 2ND= 1.3D .71- @ 4 FT
P3 = B-16 2ND =1.7D 2.1 L .9S @5FT
P4=B-162ND =3.3D2.6L1.7S@9.5ft
5 1/8 X 13 1/2 GLB
B-5 L= 10 FT TRIB = 2 FT FLR
2- 1 3/4 X X9 1/4 LVL R=2.8
P2
P1 P-3 P4
111 � -T
11.0
R=4.7k R=7.Ok
B-11 2ND 1.5D .51- 1 AS
6
10
2.3 2.8
RCR ENGINEERS. PLLC Structural Enizineers
29028 1761h AVE SE, Kent, WA 98042 (206) 295 9439
Project# Project PAUL TRIEU Date 3-25-22
Subject MAIN FLOOR Sheet MAIN-3
B-6 L= 10 FT TRIB = 2 FT FLR
2- 1 3/4 X X9 1/4 LVL R=2.8
B-7 L = 11.5 FT TRIB 3.5 FT DECK 50 PLF RAIL
4X12 DF#2
H-1 L= 5FT TRIB = 3.5 DECK 2.0 FL
2-2X8 DF#2
H- 2 L= 6.0 TRIB = 3.5 DECK 2.0 FL
2- 1 3/4 X 9 1/4 LVL
B-12 2ND 1.3D .8L 1.1S
5
10
2.6 2.4
2ND - 2.4D 2.51- 1.1 S
2.0
T
R=5.6 R=3.0
3 JACK STUDS 2 JACK STUDS
aFORTE'CM
MAIN FLR, Floor: Joist J-1
1 piece(s) 2 x 8 DF No.2 @ 12" OC
PASSED
r
r
10' 0.00" L
a a
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1132 @ 1' 1.75"
2231 (3.50")
Passed (51%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
727 @ 4.75"
1305
Passed (56%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
-844 @ 1' 1.75"
1360
Passed (62%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.129 @ 6' 3.13"
0.256
Passed (L/949)
1.0 D + 1.0 L (Alt Spans)
Total Load Defl.(in)
0.070 @ 0
0.200
Passed (2L/394)
1.0 D + 0.75 L + 0.75 S (Alt Spans)
TJ-ProT"' Rating
N/A
N/A
N/A
N/A
• Deflection criteria: LL (L/480) and TL (L/240).
• Overhang deflection criteria: LL (2L/480) and TL (2L/0.2").
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A 15% increase in the moment capacity has been added to account for repetitive member usage.
• Applicable calculations are based on Nos.
• No composite action between deck and joist was considered in analysis.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Stud wall- SPF
3.50"
3.50"
1.78"
479
653
195
1327
Blocking
2 - Stud wall - SPF
3.50"
2.25"
1.50"
40
213/-39
-20
253/-59
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
11' 6.00" o/c
Bottom Edge (Lu)
11' 6.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Spacing
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
1 - Uniform (PSF)
0 to 11' 7.00"
12"
15.0
40.0
-
Default Load
2 - Point (PLF)
0
12"
105.0
-
175.0
RF
3 - Point (PLF)
0
12"
90.0
360.0
-
2ND
4 - Point (PLF)
0
12"
150.0
-
WALL
Notes
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/9/2022 6:01:53 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
MAIN FLR, Floor: Joist J-2
1 piece(s) 2 x 8 DF No.2 @ 16" OC
PASSED
J
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
369 @ 2.50"
1434 (2.25")
Passed (26%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
290 @ 10.75"
1305
Passed (22%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
642 @ 3' 9.50"
1360
Passed (47%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.062 @ 3' 9.50"
0.179
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.078 @ 3' 9.50"
0.358
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
TJ-ProT"' Rating
N/A
N/A
N/A
N/A
• Deflection criteria: LL (L/480) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A 15% increase in the moment capacity has been added to account for repetitive member usage.
• Applicable calculations are based on Nos.
• No composite action between deck and joist was considered in analysis.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Stud wall - SPF
3.50"
2.25"
1.50"
76
303
379
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.50"
76
303
379
1 1/4" Rim Board
• Kim uoam is assumea m carry an ioaas appueo aireary aoove a, Dypassmg me memoer Deing oesignea.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
75.00" o/c
Bottom Edge (Lu)
75.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Load
Location (Side)
Spacing
Dead
(0.90)
Floor Live
(1.00)
Comments
1 - Uniform (PSF)
0 to 7' 7.00"
16"
15.0
60.0
Default Load
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/9/2022 6:04:03 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
MAIN FLR, Floor: Drop Beam B-1
2 piece(s) 1 3/4" x 9 1/4" 2.0E Microllam® LVL
PASSED
i
1' 0.00" 5' 3.96'
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2391 @ 6' 7.46"
3938 (1.50")
Passed (61%)
1.0 D + 0.75 L + 0.75 S (Alt Spans)
Shear (Ibs)
2105 @ 5' 10.21"
7074
Passed (30%)
1.15
1.0 D + 1.0 S (Alt Spans)
Moment (Ft-Ibs)
2778 @ 4' 10.51"
12884
Passed (22%)
1.15
1.0 D + 0.75 L + 0.75 S (Alt Spans)
Live Load Defl. (in)
0.021 @ 4' 0.47"
0.183
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (Alt Spans)
Total Load Defl. (in)
0.041 @ 4' 0.48"
0.274
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length
Supports Available Required
Loads to Supports (Ibs)
Accessories
Dead
Floor Live
Snow
Total
1 - Beam - DF 3.50"
3.50"
1.50"
1096
641
683
2420
Blocking
2 - Hanger on 9 1/4" DF beam 3.50"
Hanger-
1.50"
1238
485
1214
2937
See note'
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
67.00" o/c
Bottom Edge (Lu)
67.00" o/c
-Maximum allowable bracing intervals based on applied load.
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
2 - Face Mount Hanger
HGUS410
4.00"
N/A
46-10d
16-10d
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 6' 7.46"
N/A
9.4
1 - Uniform (PSF)
0 to 6' 10.96" (Front)
4' 0.00"
15.0
-
25.0
ROOF
2 - Uniform (PSF)
0 to 6' 10.96" (Front)
4' 0.00"
15.0
40.0
-
MIAN + 2ND
3 - Point (lb)
5' 3.96" (Front)
N/A
750
1200
RB-1
4 - Uniform (PLF)
0 to 6' 10.96" (Front)
N/A
100.0
WALL
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/8/2022 2:49:54 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
MAIN FLR, Floor: Drop Beam B-2
2 piece(s) 1 3/4" x 9 1/4" 2.0E Microllam® LVL
PASSED
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
11103 @ 2' 9.00"
15750 (6.00")
Passed (70%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
4694 @ 3' 9.25"
6151
Passed (76%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
-9094 @ 2' 9.00"
11204
Passed (81%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.190 @ 0
0.200
Passed (2L/348)
1.0 D + 0.75 L + 0.75 S (Alt Spans)
Total Load Defl. (in)
0.265 @ 0
0.275
Passed (2L/248)
1.0 D + 0.75 L + 0.75 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/0.2") and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Column - DF
6.00"
6.00"
4.23"
5078
5653
2381
13112
Blocking
2 - Stud wall - DF
3.50"
3.50"
2.00"
1549
2830/-504
714
5504/
None
• owcKing vaneis are assumes to carry no ioaas appuea airecoy aoove tnem ano the rwi ioaa is appuea to me memoer Deing Designeo.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
11' 4.00" o/c
Bottom Edge (Lu)
10' 11.00" o/c
-Maximum allowable bracing intervals based on applied load.
ical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 11' 3.50"
N/A
9.4
1 - Uniform (PLF)
0 to 11' 3.50" (Front)
N/A
480.0
650.0
200.0
SEE 3-1
2 - Point (lb)
0 (Front)
N/A
1100
640
680
B-1
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/8/2022 3:13:10 PM UTC
ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
MAIN FLR, Floor: Drop Beam B-3
1 piece(s) 5 1/8" x 12" 24F-V4 DF Glulam
PASSED
j
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
8550 @ 4.50"
19988 (6.00")
Passed (43%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
7950 @ 1' 6.00"
12495
Passed (64%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
27821 @ 4' 0.00"
28290
Passed (98%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.218 @ 5' 8.45"
0.375
Passed (L/620)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.431 @ 5' 9.03"
0.563
Passed (L/313)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 11' 3.00".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Column - DF
6.00"
6.00"
2.57"
4300
1361
4249
9910
Blocking
2 - Column - DF
6.00"
6.00"
1.81"
2931
1464
2651
7046
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
10' 0.00" o/c
Bottom Edge (Lu)
12' 0.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 12' 0.00"
N/A
14.9
1 - Uniform (PSF)
0 to 8' 0.00" (Front)
4' 0.00"
15.0
-
25.0
RF
2 - Uniform (PSF)
0 to 8' 0.00" (Front)
2' 6.00"
15.0
40.0
-
2ND
3 - Uniform (PSF)
0 to 8' 0.00" (Front)
2' 6.00"
15.0
40.0
MAIN
4 - Uniform (PSF)
8' 0.00" to 11' 7.00" (Front)
5' 0.00"
15.0
40.0
MAIN
5 - Uniform (PLF)
0 to 8' 0.00" (Front)
N/A
150.0
-
-
WALL
6 - Point (lb)
4' 0.00" (Front)
N/A
3300
-
4900
RB-5
7 - Point (lb)
8' 0.00" (Front)
N/A
1200
500
1200
B-1
Notes
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/8/2022 3:09:34 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
.I F O R T E M) MEMBER REPORT PASSED
MAIN FLR, Floor: Drop Beam B-4
1 piece(s) 5 1/8" x 13 1/2" 24F-V4 DF Glulam
Overall Length: 120.00
f
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
11674 @ 4.50"
19988 (6.00")
Passed (58%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
11338 @ 1' 7.50"
14057
Passed (81%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Pos Moment (Ft-Ibs)
35198 @ 5' 0.00"
35805
Passed (98%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)
0.192 @ 5' 10.09"
0.375
Passed (L/702)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.411 @ 5' 10.02"
0.563
Passed (L/328)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 11' 3.00".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Column - DF
6.00"
6.00"
3.50"
6264
2682
4531
13477
None
2 - Column - DF
6.00"
6.00"
3.15"
5598
3678
2869
12145
None
Lateral Bracing sm
Bracing Intervals
Comments
Top Edge (Lu)
8' 8.00" o/c
Bottom Edge (Lu)
12' 0.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 12' 0.00"
N/A
16.8
1 - Uniform (PSF)
0 to 12' 0.00" (Front)
2' 0.00"
15.0
40.0
-
Default Load
2 - Point (lb)
3' 0.00" (Front)
N/A
3400
-
4800
Pi
3 - Point (lb)
4' 0.00" (Front)
N/A
1700
700
-
P2
4 - Point (lb)
5' 0.00" (Front)
N/A
1700
2100
900
P3
5 - Uniform (PLF)
0 to 12' 0.00" (Front)
N/A
100.0
-
-
WALL
6 - Point (lb)
9' 6.00" (Front)
N/A
3300
2600
1700
P4
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/8/2022 3:50:02 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
MAIN FLR, Floor: Drop Beam B-5
2 piece(s) 1 3/4" x 9 1/4" 2.0E Microllam@ LVL
PASSED
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3184 @ 2.00"
5206 (3.50")
Passed (61%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
2478 @ 1' 0.75"
6151
Passed (40%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
7106 @ 4' 9.50"
11204
Passed (63%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.174 @ 4' 9.50"
0.308
Passed (L/639)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.262 @ 4' 9.50"
0.463
Passed (L/423)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Stud wall - SPF
3.50"
3.50"
2.14"
1075
2108
3183
Blocking
2 - Stud wall - SPF
3.50"
3.50"
2.14"
1075
2108
3183
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the tull load Is applied to the member Dung designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
9' 7.00" o/c
Bottom Edge (Lu)
9' 7.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Comments
0 - Self Weight (PLF)
0 to 9' 7.00"
N/A
9.4
1 - Uniform (PSF)
0 to 9' 7.00" (Front)
1110.001,
15.0
40.0
Default Load
2 - Uniform (PLF)
0 to 9' 7.00" (Front)
N/A
50.0
-
WALL
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/9/2022 10:26:41 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
MAIN FLR, Floor: Drop Beam B-6
2 piece(s) 4 x 10 DF No.2
PASSED
I
i1e][41I11
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2162 @ 2.00"
15313 (3.50")
Passed (14%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
1814 @ 1' 0.75"
7770
Passed (23%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
8746 @ 5' 0.00"
10332
Passed (85%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)
0.105 @ 5' 2.90"
0.342
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.188 @ 5' 2.86"
0.512
Passed (L/653)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Supports Available Required
Loads to Supports (Ibs)
Accessories
Dead
Floor Live
Snow
Total
1 - Stud wall - DF 3.50"
3.50"
F 1.50"
933
1058
581
2572
None
2 - Stud wall - DF 3.50"
3.50"
1 1.50"
859
1012
519
2390
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
10' 7.00" o/c
Bottom Edge (Lu)
10' 7.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 10' 7.00"
N/A
16.4
1 - Uniform (PSF)
0 to 10' 7.00" (Front)
2' 0.00"
15.0
60.0
-
Default Load
2 - Point (PLF)
5' 0.00" (Front)
110.001,
1300.0
800.0
1100.0
B-12
0
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/8/2022 4:15:10 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
MAIN FLR, Wall: Header H-1
2 piece(s) 2 x 8 DF No.2
PASSED
1
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
992 @ 0
2813 (1.50")
Passed (35%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
717 @ 8.75"
2610
Passed (27%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
1302 @ 2' 7.50"
2365
Passed (55%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.033 @ 2' 7.50"
0.175
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.042 @ 2' 7.50"
0.262
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Trimmer - SPF
1.50"
1.50"
1.50"
231
761
992
None
2 - Trimmer - SPF
1.50"
1.50"
1 1.50"
231
761
992
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
5' 3.00" o/c
Bottom Edge (Lu)
5' 3.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Comments
0 - Self Weight (PLF)
0 to 5' 3.00"
N/A
5.5
1 - Uniform (PSF)
0 to 5' 3.00"
T 6.00"
15.0
60.0
DECK
2 - Uniform (PSF)
0 to 5' 3.00"
2' 0.00"
15.0
40.0
FLR
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
3/9/2022 6:33:40 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
aFORTE'CM
MAIN FLR, Wall: Header H-2
2 piece(s) 1 3/4" x 9 1/4" 2.0E Microllam@ LVL
PASSED
FI
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
4817 @ 3.00"
11419 (4.50")
Passed (42%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
4379 @ 1' 1.75"
6151
Passed (71%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
7678 @ 2' 0.00"
11204
Passed (69%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.071 @ 3' 2.28"
0.208
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.122 @ T 2.02"
0.313
Passed (L/614)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Trimmer - SPF
4.50"
4.50"
1.90"
2038
2779
792
5609
None
2 - Trimmer - SPF
3.00"
3.00"
1.50"
971
1643
308
2922
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
68.00" o/c
Bottom Edge (Lu)
68.00" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 6' 7.50"
N/A
9.4
--
--
1 - Uniform (PSF)
0 to 6' 7.50"
3' 6.00"
15.0
60.0
DECK
2 - Uniform (PSF)
0 to 6' 7.50"
2' 0.00"
15.0
40.0
FLR
3 - Point (lb)
2' 0.00"
N/A
2400
2500
1100
POST ABOVE
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Robert Raichle
RCR engineers
(206) 295-9439
rcraichle@hotmail.com
6/8/2022 4:19:35 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: PAUL TRIEU 2022
Page 1 / 1
RCR ENGINEERS. PLLC Structural EnLyineers
29028 176r" AVE SE, Kent, WA 98042 (206) 295 9439
Project# Project PAUL & NANCY TRIEU Date 3-1-2022
Subject FOUNDATION Sheet F-1
SOIL BRG 2500psf PER REPORT BY NGA DATED 10-12-21
1) SOLID LINES NEW FTGS SOILS ENGINER TO VERIFY SUITABLE BEARING BEFORE POURING
2) DASHED LINES SHOW THE EXISTING FOOTINGS WHICH SHOULD BE INVESTIGATED BY THE
SOILS ENGINEER AND SUB CONTRACTOR FOR DETERMINATION OF UNDERPINNING REQUIREMENTS
3) PIN PILES TO RELEVEL FOOTINGS GRID B & 2 SEE
- I b I F2.0
2.0
0.8k1f
1.6k
Y
N
`1' 1'6"
1.3 4.0
F2.0
- - 3.Ok
----------- -�--- 0_----
=I III I I I I I
7.4k 13.4k
I F2.5�I
N
I
I ' I I I I I � � �
' III I I ' N
13.OK 2'0": - - - 18.11k1 I I I I I -
1 0 F3.0�I1i L� l
N EX FTG & COL
' i VRFY
9.9k
' 13.4k I
-
---�I�--- -- 2-------li� II I ------I
=7--------------------------10.�---
I I I
r'
I I Y
I 5.2 F2.0 N
• C - -
I ~ L_I L
` I I
I '
_ � 1.9 3.2
F.8- - - - - -
I '
2.6
L- - - - - - - - - - - - - - - - -
- - - - , - - - - - - - - - - -
0.9k1f
1.3+4.0 2.6+4.0
F61F2.0 g F2.0
4.0 k2.01 F2.0F2.0
7.0
L- 13.L
I I
2'-0"
---------- ---
� 2.0
Y
C
(V
-12.6k
F.9
K�� �7 K���' K' �-� Engineers
K� UH P�0 �U P� UH �� 0� �� U� U 'U '� . Str�'
29028 170th AVE 8B, Kent, WA98O42(2O6) 295 9439
Project# proj ect PAUL TRIEU Date O 1322
Subject WALLS NORTH ELEVATION Sheet W-1
A-
L 4X6 STUD @ RF BM
- - - - lZ
poll
LEIGHT
ilivolm, 111 0 Ift 0
-------------
-----------------
FLMR
------------
1
2X6DF#2@16
1A
1-2XO+JACK STUD
1B
2-2XO+JACK STUD
1C
4XG+JACK STUD
1D
4X8PDST
2
2X6DF#2@16
2A
1'2XO+JACK STUD
2B
3-2X0+2JACK STUDS
2C
2-2X8+3JACK STUDS
RCR ENGINEERS, PLLC Structural Engineers
29028 176r" AVE SE, Kent, WA 98042 (206) 295 9439
Project# Project PAUL & NANCY TRIEU Date 6-13-22
Subject WALLS WEST ELEVATION Sheet W-2
LOGE
,5'J•
*Z&-
�EOHi
�ECK
N �EAGEft
HEIGHT
>, 1 A
2A >~ 2
I �
3
------------------
1
ra-0� 1
rr-Jl. 1----------
M FGUO T=
6X6 1
VA
T______________
LOGE
1SJ•
FLA�
N� Hf I,�al
TGP�
E.
MM
HE/OEL
HEGHT
o- —*
1______-------- IQW
aa�
19(11ST GFOUHWT To"E AS I3
RCR ENGINEERS, PLLC Structural Engineers
29028 176r" AVE SE, Kent, WA 98042 (206) 295 9439
Project# Project PAUL & NANCY TRIEU Date 6-13-22
Subject WALLS SOUTH ELEVATION Sheet W-3
W.
B•101lC
r EAOF'R
HE1pHT
S-T I 3.10-
1C Ef 1B
CRA— SPACE BEYOND
51'-1P
0
— 213
ENTRY
TRUSS
6'-101/C PLATE
CUTE
HEADER
HEIGHT
IN IN
==
1
11
11
II II
I I CRANE SPACE BEYOND 1 I
............. pOzsR ;
1 I G=HEIOHr
— II
_T11T Till
RCR ENGINEERS, PLLC Structural Engineers
29028 176r" AVE SE, Kent, WA 98042 (206) 295 9439
Project# Project PAUL & NANCY TRIEU Date 6-13-22
Subject WALLS EAST ELEVATION Sheet W-4
YOGE
11�-0.1 HEIGHT
ENTRY
TRUSS
--
r �HEApER
HEIGHT
3 1/2 X 3 1/2 X14 HSS
aa-
aR.�wEwn
Ia'd'1
---------------
=--------
-----
mi
H111 ilililfilrom-
M-,- I'
I I
I I
�1 I
I
I
T__________________
EXISTING FOUNDATION TO RENYIN AS IS
—W —*
asnaa -
mrn I�r
la-o-I
RCR ENGINEERS. PLLC Structural Enizineers
29028 1761h AVE SE, Kent, WA 98042 (206) 295 9439
Project# Project PAUL TRIEU Date 1-29-21
Subject WALL STUDS Sheet W-3
WIND LOAD = 24.7 psf LRFD
ROOF DL=15 SL=25
FLOORS DL=15 LL=40
1 - HT = 9 FT TRIB = 12FT 2X6 DF#2 @ 16
1A - WINDOW MAX =4 FT 1-2X6 + JACK STUD
1 B - WINDOW MAX = 8 FT 10FT HT 1-2X6 + JACK STUD
1 C - WINDOW MAX = 7 FT 11 FT HT 2-2X6 + JACK STUD
2 - HT = 10 FT TRIB = 12FT
2A - WINDOW MAX =5 FT
2X6 DF#2 @ 16
1-2X6 + JACK STUD
2B DOOR 8X16 2--2X6 + 2 JACK STUDS
V1.1 4-12-2020 RCR Engineers PLLC
29028 17th Ave SE
Kent, WA 98042
WOOD STUD DESIGN
Project TRIEU
Title STUD 1
MATERIAL
Lumber grade = I DF-L 2-4 No.2
Fb (psi) = 900 Fb*Cd*Cr*Cf*Cp= 1147
Fc (psi) = 1350 Fc*Cd*Cf*Cp= 985
E (ksi) = 1600
Emin (ksi) = 580
MEMBER DATA
HT (FT) =
b (in) =
1.5
Braced
Multiple Studs
No
Number
d (in) =
5.5
This axis unbraced
Spacing (in) =
16
Crb I
Yes
Repetitive Stress =
LOADS
AXIAL plf
LATERAL** psf
Cd
RESULTS
Axial ecc(in)* = I 0.5
*Pos ecc adds to pos lat load
I/d < = 50? = 20
1.15 4x max & 3 or more @24"max
DL(ASD) FLL(ASD) RLL(ASD) SL(ASD) WL(LRFD) EQ(LRFD)
0.9 1.00 1.00 1.15 1.60 1.60
** Lateral loads cause bending parallel to "d" dimension
*** duration factor included for appropriate load cases
CASE 1
16-8 DL
CASE 2
16-9 DL + FILL
CASE 3
16-10
DL + RILL or SL
CASE4
16-11
DL+0.75(FLL+(RLLorSL))
CASE5a
16-12
DL+0.6W
CASE5b
16-12
DL+0.7E
CASE6a
16-13
DL+0.75(FLL+0.6W+(RLLorSL))
CASE6b
16-14
DL+0.75(FILL +0.7E+(RILL orSL))
CASE
16-15
0.6DL+0.6W
CASE
16-16
0.6DL+0.7E
MAX=
M ft-# Axial # Unity DEFL in
ASD ASD
10
240
0.05
0.00
10
240
0.05
0.00
27
640
0.11
0.00
23
540
0.10
0.00
213
240
0.22
0.09
48
240
0.08
0.02
174
540
0.23
0.07
51
540
0.12
0.00
209
144
0.20
0.00
48
240
0.08
0.02
213
640
0.23
0.09
Allow End Bearing = 5156 12%
L/1217
L/180 max
Page 1
1/29/2021
1/29/2021
V1.14-12-2020 RCR Engineers PLLC Page 1
29028 17th Ave SE 1/29/2021
Kent, WA 98042
X 1 § 1 i
Project ITRIEU
Title I STUD 1A
MATERIAL
Lumber grade = I DF-L 2-4 No.2
Fb (psi) = 900 Fb*Cd*Cr*Cf*Cp= 1044
Fc (psi) = 1350 Fc*Cd*Cf*Cp= 985
E (ksi) = 1600
Emin (ksi) = 580
WALL OPENING
HT (FT) _ � Width (FT) = 4
Stud Spacing (in) 16 Height (FT) = 5
Sill Ht (FT) = 3
King / Jack Stud Framing Method
IS97_1111
AXIAL plf
LATERAL** psf
CD
DL(ASD) FLUASD) RLL(ASD) SUASD) WL(LRFD) EQ(LRFD)
180
0
0
300
0
0
0
0
0
0
25
4
0.90 1.00 1.00 1.15 1.60 1.60
* Pos ecc adds to pos lat load
** Lateral loads cause bending parallel to "d" dimension
*** duration factor included for appropriate load cases
King stud King stud resists lat loads Jack stud Jack stud resists vert loads
b (in) = 1.5 b (in) = 1.5
d (in) = 5.5 d (in) = 5.5
Axial ecc(in) = 0.5 Axial ecc(in) = 1
Number = 1 4x max & 3 or more @24"max Number = 1
Repetitive Stressl No Crb = 1 Repetitive Stressl No
M ft-# Axial # Unity DEFL in M ft-# Axial # Unity
MAX= 405 1 0 1 0.38 1 0.18 L/609 MAX= 53 1 1280 1 0.19
Allow End Bearing = 5156 0% L/180 max Allow End Bearing = 5156 25%
Top Window Trimmer b (in) = 1.5 d (in) = 5.5 Number 1�
M ft-# Unity DEFL in
MAX=F 1296 0.12 1 0.00 L/20540 L/180 max
Bot Window Trimmer b (in) = 1.5 d (in) = 5.5 Number
M ft-# Unity DEFL in
MAX= 1 0.16 1 0.00 L/15405 L/180 max
V1.14-12-2020
CASE 1 DL
CASE 2 DL + FLL
CASE 3 DL + RLL or SL
CASE 4 DL+0.75( FLL +(RLL or SL))
CASE 5a DL+0.6W
CASE 5b DL+0.7E
CASE 6a DL+0.75( FLL +0.6W + (RLL or SL))
CASE 6b DL+0.75( FLL + 0.7E + (RLL orSL))
CASE 7 0.6DL+ 0.6W
CASE 80.6DL+0.7E
TOP TRIMMER
CASE 1
16-8 DL
CASE 2
16-9 DL + FLL
CASE 3
16-10
DL + RLL or SL
CASE
16-11
DL + 0.75( FLL + (RLL orSL))
CASE 5a
16-12
DL+0.6W
CASE5b
16-12
DL+0.7E
CASE6a
16-13
DL + 0.75( FLL + 0.6W + (RLL orSL))
CASE6b
16-14
DL + 0.75( FLL + 0.7E + (RLL orSL))
CASE
16-15
0.6DL+0.6W
CASE
16-16
0.6DL+0.7E
BOT TRIMMER
CASE 1
16-8 DL
CASE 2
16-9 DL + FLL
CASE 3
16-10
DL + RLL or SL
CASE
16-11
DL + 0.75( FLL + (RLL orSL))
CASE 5a
16-12
DL+0.6W
CASE5b
16-12
DL+0.7E
CASE6a
16-13
DL + 0.75( FLL + 0.6W + (RLL orSL))
CASE6b
16-14
DL + 0.75( FLL + 0.7E + (RLL orSL))
CASE
16-15
0.6DL+0.6W
CASE
16-16
0.6DL+0.7E
RCR Engineers PLLC
29028 17th Ave SE
Kent, WA 98042
KING STUD
JACK STUD
MOM
AXIAL
UNITY
DER
MOM
AXIAL
UNITY
ASD
ASD
ASD
ASD
0
0
0.00
0.01
20
480
0.10
0
0
0.00
0.01
20
480
0.10
0
0
0.00
0.01
53
1280
0.19
0
0
0.00
0.01
17
405
0.06
405
0
0.38
0.18
8
90
0.04
76
0
0.07
0.03
8
90
0.04
304
0
0.29
0.13
8
90
0.04
57
0
0.05
0.00
29
349
0.06
405
0
0.38
0.00
5
54
0.02
76
0
0.07
0.03
2
27
0.01
MOM UNITY DER
ASD
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
1296
0.12
0.00
202
0.12
0.00
972
0.09
0.00
151
0.01
0.00
1296
0.12
0.00
202
0.02
0.00
MOM UNITY DER
ASD
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
1728
0.16
0.00
269
0.02
0.00
1296
0.12
0.00
202
0.02
0.00
1728
0.16
0.00
269
0.02
0.00
Page 2
1/29/2021
V1.14-12-2020 RCR Engineers PLLC Page 1
29028 17th Ave SE 6/13/2022
Kent, WA 98042
X 1 § 1 i
Project ITRIEU
Title ISTUD 16
MATERIAL
Lumber grade = I DF-L 2-4 No.2
Fb (psi) = 900 Fb*Cd*Cr*Cf*Cp= 1014
Fc (psi) = 1350 Fc*Cd*Cf*Cp= 84S
E (ksi) = 1600
Emin (ksi) = S80
WALL OPENING
HT (FT) = 10 Width (FT) = 8
Stud Spacing (in) 16 Height (FT) = 5
Sill Ht (FT) = 3
King / Jack Stud Framing Method
IS97_1111
AXIAL plf
LATERAL** psf
CD
DL(ASD) FLUASD) RLL(ASD) SUASD) WL(LRFD) EQ(LRFD)
180
0
0
300
0
0
0
0
0
0
25
4
0.90 1.00 1.00 1.15 1.60 1.60
* Pos ecc adds to pos lat load
** Lateral loads cause bending parallel to "d" dimension
*** duration factor included for appropriate load cases
King stud King stud resists lat loads Jack stud Jack stud resists vert loads
b (in) = 1.5 b (in) = 1.5
d (in) = 5.5 d (in) = 5.5
Axial ecc(in) = 0.5 Axial ecc(in) = 1
Number = 1 4x max & 3 or more @24"max Number = 1
Repetitive Stressl No Crb = 1 Repetitive Stressl No
M ft-# Axial # Unity DEFL in M ft-# Axial # Unity
MAX= 875 1 0 1 0.86 1 0.47 L/254 MAX= 93 1 2240 1 0.38
Allow End Bearing = 5156 0% L/180 max Allow End Bearing = 5156 43%
Top Window Trimmer b (in) = 1.5 d (in) = 5.5 Number 1
M ft-# Unity DEFL in
MAX= F 6048 0.56 0.02 1 L/4401 L/180 max
Bot Window Trimmer b (in) = 1.5 d (in) = 5.5 Number 1�
M ft-# Unity DEFL in
MAX= 1 0.63 1 0.02 1 L/3851 L/180 max
V1.14-12-2020
CASE 1 DL
CASE 2 DL + FLL
CASE 3 DL + RLL or SL
CASE 4 DL+0.75( FLL +(RLL or SL))
CASE 5a DL+0.6W
CASE 5b DL+0.7E
CASE 6a DL+0.75( FLL +0.6W + (RLL or SL))
CASE 6b DL+0.75( FLL + 0.7E + (RLL orSL))
CASE 7 0.6DL+ 0.6W
CASE 80.6DL+0.7E
TOP TRIMMER
CASE 1
16-8 DL
CASE 2
16-9 DL + FLL
CASE 3
16-10
DL + RLL or SL
CASE
16-11
DL + 0.75( FLL + (RLL orSL))
CASE 5a
16-12
DL+0.6W
CASE5b
16-12
DL+0.7E
CASE6a
16-13
DL + 0.75( FLL + 0.6W + (RLL orSL))
CASE6b
16-14
DL + 0.75( FLL + 0.7E + (RLL orSL))
CASE
16-15
0.6DL+0.6W
CASE
16-16
0.6DL+0.7E
BOT TRIMMER
CASE 1
16-8 DL
CASE 2
16-9 DL + FLL
CASE 3
16-10
DL + RLL or SL
CASE
16-11
DL + 0.75( FLL + (RLL orSL))
CASE 5a
16-12
DL+0.6W
CASE5b
16-12
DL+0.7E
CASE6a
16-13
DL + 0.75( FLL + 0.6W + (RLL orSL))
CASE6b
16-14
DL + 0.75( FLL + 0.7E + (RLL orSL))
CASE
16-15
0.6DL+0.6W
CASE
16-16
0.6DL+0.7E
RCR Engineers PLLC
29028 17th Ave SE
Kent, WA 98042
KING STUD
JACK STUD
MOM
AXIAL
UNITY
DER
MOM
AXIAL
UNITY
ASD
ASD
ASD
ASD
0
0
0.00
0.01
35
840
0.19
0
0
0.00
0.01
35
840
0.19
0
0
0.00
0.01
93
2240
0.38
0
0
0.00
0.01
17
405
0.07
875
0
0.86
0.47
8
90
0.04
163
0
0.16
0.09
8
90
0.04
656
0
0.64
0.35
8
90
0.04
123
0
0.12
0.00
29
349
0.06
875
0
0.86
0.00
5
54
0.03
163
0
0.16
0.09
2
27
0.01
MOM UNITY DER
ASD
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
6048
0.56
0.02
941
0.56
0.00
4536
0.42
0.02
706
0.06
0.00
6048
0.56
0.02
941
0.09
0.00
MOM UNITY DER
ASD
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
6912
0.63
0.02
1075
0.10
0.00
5184
0.48
0.02
806
0.07
0.00
6912
0.63
0.02
1075
0.10
0.00
Page 2
6/13/2022
V1.14-12-2020 RCR Engineers PLLC Page 1
29028 17th Ave SE 6/13/2022
Kent, WA 98042
X 1 § 1 i
Project ITRIEU
Title I STUD 1C
MATERIAL
Lumber grade = I DF-L 2-4 No.2
Fb (psi) = 900 Fb*Cd*Cr*Cf*Cp= 979
Fc (psi) = 1350 Fc*Cd*Cf*Cp= 72S
E (ksi) = 1600
Emin (ksi) = S80
WALL OPENING
HT (FT) = 11 Width (FT) = 7
Stud Spacing (in) 16 Height (FT) = 3
Sill Ht (FT) = 8
King / Jack Stud Framing Method
IS97_1111
AXIAL plf
LATERAL** psf
CD
DL(ASD) FLUASD) RLL(ASD) SUASD) WL(LRFD) EQ(LRFD)
180
0
0
300
0
0
0
0
0
0
25
4
0.90 1.00 1.00 1.15 1.60 1.60
* Pos ecc adds to pos lat load
** Lateral loads cause bending parallel to "d" dimension
*** duration factor included for appropriate load cases
King stud King stud resists lat loads Jack stud Jack stud resists vert loads
b (in) = 1.5 b (in) = 1.5
d (in) = 5.5 d (in) = 5.5
Axial ecc(in) = 0.5 Axial ecc(in) = 1
Number = 2 4x max & 3 or more @24"max Number = 1
Repetitive Stressl No Crb = 1 Repetitive Stressl No
M ft-# Axial # Unity DEFL in M ft-# Axial # Unity
MAX= 945 1 0 1 0.48 1 0.31 L/427 MAX= 83 1 2000 1 0.38
Allow End Bearing = 10313 0% L/180 max Allow End Bearing = 5156 39%
Top Window Trimmer b (in) = 1.5 d (in) = 5.5 Number 1
M ft-# Unity DEFL in
MAX=F 1985 0.18 0.01 1 L/13414 L/180 max
Bot Window Trimmer b (in) = 1.5 d (in) = 5.5 Number 1
M ft-# Unity DEFL in
MAX= 7277 0.67 1 0.02 1 L/3658 I L/180 max
V1.14-12-2020
CASE 1 DL
CASE 2 DL + FLL
CASE 3 DL + RLL or SL
CASE 4 DL+0.75( FLL +(RLL or SL))
CASE 5a DL+0.6W
CASE 5b DL+0.7E
CASE 6a DL+0.75( FLL +0.6W + (RLL or SL))
CASE 6b DL+0.75( FLL + 0.7E + (RLL orSL))
CASE 7 0.6DL+ 0.6W
CASE 80.6DL+0.7E
TOP TRIMMER
CASE 1
16-8 DL
CASE 2
16-9 DL + FLL
CASE 3
16-10
DL + RLL or SL
CASE
16-11
DL + 0.75( FLL + (RLL orSL))
CASE 5a
16-12
DL+0.6W
CASE5b
16-12
DL+0.7E
CASE6a
16-13
DL + 0.75( FLL + 0.6W + (RLL orSL))
CASE6b
16-14
DL + 0.75( FLL + 0.7E + (RLL orSL))
CASE
16-15
0.6DL+0.6W
CASE
16-16
0.6DL+0.7E
BOT TRIMMER
CASE 1
16-8 DL
CASE 2
16-9 DL + FLL
CASE 3
16-10
DL + RLL or SL
CASE
16-11
DL + 0.75( FLL + (RLL orSL))
CASE 5a
16-12
DL+0.6W
CASE5b
16-12
DL+0.7E
CASE6a
16-13
DL + 0.75( FLL + 0.6W + (RLL orSL))
CASE6b
16-14
DL + 0.75( FLL + 0.7E + (RLL orSL))
CASE
16-15
0.6DL+0.6W
CASE
16-16
0.6DL+0.7E
RCR Engineers PLLC
29028 17th Ave SE
Kent, WA 98042
KING STUD
JACK STUD
MOM
AXIAL
UNITY
DER
MOM
AXIAL
UNITY
ASD
ASD
ASD
ASD
0
0
0.00
0.01
31
750
0.20
0
0
0.00
0.01
31
750
0.20
0
0
0.00
0.01
83
2000
0.38
0
0
0.00
0.01
17
405
0.08
945
0
0.48
0.31
8
90
0.05
176
0
0.09
0.06
8
90
0.05
709
0
0.36
0.23
8
90
0.05
132
0
0.07
0.00
29
349
0.07
945
0
0.48
0.00
5
54
0.03
176
0
0.09
0.06
2
27
0.01
MOM UNITY DER
ASD
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
1985
0.18
0.01
309
0.18
0.00
1488
0.14
0.00
232
0.02
0.00
1985
0.18
0.01
309
0.03
0.00
MOM UNITY DER
ASD
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
7277
0.67
0.02
1132
0.10
0.00
5457
0.50
0.02
849
0.08
0.00
7277
0.67
0.02
1132
0.10
0.00
Page 2
6/13/2022
V1.1 4-12-2020 RCR Engineers PLLC
29028 17th Ave SE
Kent, WA 98042
WOOD STUD DESIGN
Project TRIEU
Title STUD 2
MATERIAL
Lumber grade = I DF-L 2-4 No.2
Fb (psi) = 900 Fb*Cd*Cr*Cf*Cp= 1147
Fc (psi) = 1350 Fc*Cd*Cf*Cp= 985
E (ksi) = 1600
Emin (ksi) = 580
MEMBER DATA
HT (FT) =
b (in) = 1.5 Braced
Multiple Studs No Number
d (in) = 5.5 This axis unbraced
Spacing (in) = 16
Crb I Yes Repetitive Stress =
LOADS
AXIAL plf
LATERAL** psf
Cd
RESULTS
Axial ecc(in)* = I 0.5
*Pos ecc adds to pos lat load
I/d < = 50? = 20
1.15 4x max & 3 or more @24"max
DL(ASD) FLL(ASD) RLL(ASD) SL(ASD) WL(LRFD) EQ(LRFD)
360
480
0
300
0
0
0
0
0
0
25
4
0.9 1.00 1.00 1.15 1.60 1.60
** Lateral loads cause bending parallel to "d" dimension
*** duration factor included for appropriate load cases
CASE 1
16-8 DL
CASE 2
16-9 DL + FILL
CASE 3
16-10
DL + RILL or SL
CASE4
16-11
DL+0.75(FLL+(RLLorSL))
CASE5a
16-12
DL+0.6W
CASE5b
16-12
DL+0.7E
CASE6a
16-13
DL+0.75(FLL+0.6W+(RLLorSL))
CASE6b
16-14
DL+0.75(FILL +0.7E+(RILL orSL))
CASE
16-15
0.6DL+0.6W
CASE
16-16
0.6DL+0.7E
MAX=
M ft-# Axial # Unity DEFL in
ASD ASD
20
480
0.10
0.01
47
1120
0.21
0.01
37
880
0.16
0.01
53
1260
0.23
0.01
223
480
0.27
0.09
58
480
0.13
0.02
204
1260
0.36
0.07
81
1260
0.25
0.00
215
288
0.23
0.00
58
480
0.13
0.02
223
1260
0.36
0.09
Allow End Bearing = 5156 24%
L/1217
L/180 max
Page 1
1/29/2021
1/29/2021
V1.14-12-2020 RCR Engineers PLLC Page 1
29028 17th Ave SE 1/29/2021
Kent, WA 98042
X 1 § 1 i
Project ITRIEU
Title I STUD 2A
MATERIAL
Lumber grade = I DF-L 2-4 No.2
Fb (psi) = 900 Fb*Cd*Cr*Cf*Cp= 1044
Fc (psi) = 1350 Fc*Cd*Cf*Cp= 985
E (ksi) = 1600
Emin (ksi) = 580
WALL OPENING
HT (FT) _ � Width (FT) = 5
Stud Spacing (in) 16 Height (FT) = 5
Sill Ht (FT) = 3
King / Jack Stud Framing Method
IS97_1111
AXIAL plf
LATERAL** psf
CD
DL(ASD) FLUASD) RLL(ASD) SUASD) WL(LRFD) EQ(LRFD)
360
480
0
300
0
0
0
0
0
0
25
4
0.90 1.00 1.00 1.15 1.60 1.60
* Pos ecc adds to pos lat load
** Lateral loads cause bending parallel to "d" dimension
*** duration factor included for appropriate load cases
King stud King stud resists lat loads Jack stud Jack stud resists vert loads
b (in) = 1.5 b (in) = 1.5
d (in) = 5.5 d (in) = 5.5
Axial ecc(in) = 0.5 Axial ecc(in) = 1
Number = 1 4x max & 3 or more @24"max Number = 1
Repetitive Stressl No Crb = 1 Repetitive Stressl No
M ft-# Axial # Unity DEFL in M ft-# Axial # Unity
MAX= 481 1 0 1 0.46 1 0.21 L/513 MAX= 111 1 2660 1 0.52
Allow End Bearing = 5156 0% L/180 max Allow End Bearing = 5156 52%
Top Window Trimmer b (in) = 1.5 d (in) = 5.5 Number 2
M ft-# Unity DEFL in
MAX=F 2025 0.09 1 0.00 L/26291 L/180 max
Bot Window Trimmer b (in) = 1.5 d (in) = 5.5 Number
M ft-# Unity DEFL in
MAX= 1 0.12 1 0.00 L/19719 L/180 max
V1.14-12-2020
CASE 1 DL
CASE 2 DL + FLL
CASE 3 DL + RLL or SL
CASE 4 DL+0.75( FLL +(RLL or SL))
CASE 5a DL+0.6W
CASE 5b DL+0.7E
CASE 6a DL+0.75( FLL +0.6W + (RLL or SL))
CASE 6b DL+0.75( FLL + 0.7E + (RLL orSL))
CASE 7 0.6DL+ 0.6W
CASE 80.6DL+0.7E
TOP TRIMMER
CASE 1
16-8 DL
CASE 2
16-9 DL + FLL
CASE 3
16-10
DL + RLL or SL
CASE
16-11
DL + 0.75( FLL + (RLL orSL))
CASE 5a
16-12
DL+0.6W
CASE5b
16-12
DL+0.7E
CASE6a
16-13
DL + 0.75( FLL + 0.6W + (RLL orSL))
CASE6b
16-14
DL + 0.75( FLL + 0.7E + (RLL orSL))
CASE
16-15
0.6DL+0.6W
CASE
16-16
0.6DL+0.7E
BOT TRIMMER
CASE 1
16-8 DL
CASE 2
16-9 DL + FLL
CASE 3
16-10
DL + RLL or SL
CASE
16-11
DL + 0.75( FLL + (RLL orSL))
CASE 5a
16-12
DL+0.6W
CASE5b
16-12
DL+0.7E
CASE6a
16-13
DL + 0.75( FLL + 0.6W + (RLL orSL))
CASE6b
16-14
DL + 0.75( FLL + 0.7E + (RLL orSL))
CASE
16-15
0.6DL+0.6W
CASE
16-16
0.6DL+0.7E
RCR Engineers PLLC
29028 17th Ave SE
Kent, WA 98042
KING STUD
JACK STUD
MOM
AXIAL
UNITY
DER
MOM
AXIAL
UNITY
ASD
ASD
ASD
ASD
0
0
0.00
0.01
48
1140
0.24
0
0
0.00
0.01
111
2660
0.52
0
0
0.00
0.01
87
2090
0.35
0
0
0.00
0.01
24
585
0.10
481
0
0.46
0.21
15
180
0.07
90
0
0.09
0.04
15
180
0.07
361
0
0.34
0.16
15
180
0.07
67
0
0.06
0.00
67
799
0.14
481
0
0.46
0.00
9
108
0.04
90
0
0.09
0.04
5
54
0.02
MOM UNITY DER
ASD
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
2025
0.09
0.00
315
0.09
0.00
1519
0.07
0.00
236
0.01
0.00
2025
0.09
0.00
315
0.01
0.00
MOM UNITY DER
ASD
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
2700
0.12
0.00
420
0.02
0.00
2025
0.09
0.00
315
0.01
0.00
2700
0.12
0.00
420
0.02
0.00
Page 2
1/29/2021
V1.14-12-2020 RCR Engineers PLLC Page 1
29028 17th Ave SE 6/13/2022
Kent, WA 98042
%1 1 § 1 i
Project ITRIEU
Title ISTUD 26
MATERIAL
Lumber grade = I DF-L 2-4 No.2
Fb (psi) = 900 Fb*Cd*Cr*Cf*Cp= 1044
Fc (psi) = 1350 Fc*Cd*Cf*Cp= 985
E (ksi) = 1600
Emin (ksi) = 580
WALL OPENING
HT (FT) _ � Width (FT) = 16
Stud Spacing (in) 16 Height (FT) = 7
Sill Ht (FT) = 0
King / Jack Stud Framing Method
IS97_1111
AXIAL plf
LATERAL** psf
CD
DL(ASD) FLL(ASD) RLL(ASD) SL(ASD) WL(LRFD) EQ(LRFD)
360
480
0
300
0
0
0
0
0
0
25
4
0.90 1.00 1.00 1.15 1.60 1.60
* Pos ecc adds to pos lat load
** Lateral loads cause bending parallel to "d" dimension
*** duration factor included for appropriate load cases
King stud King stud resists lat loads Jack stud Jack stud resists vert loads
b (in) = 1.5 b (in) = 1.5
d (in) = 5.5 d (in) = 5.5
Axial ecc(in) = 0.5 Axial ecc(in) = 1
Number = 2 4x max & 3 or more @24"max Number = 2
Repetitive Stressl No Crb = 1 Repetitive Stressl No
M ft-# Axial # Unity DEFL in M ft-# Axial # Unity
MAX= 1316 1 0 1 0.62 1 0.29 L/375 MAX= 303 1 7280 1 0.71
Allow End Bearing = 10313 0% L/180 max Allow End Bearing = 10313 71%
Top Window Trimmer b (in) = 1.5 d (in) = 5.5 Number 1
M ft-# Unity DEFL in UNITY FAILED
MAX= 1 2.86 0.22 1 L/856 L/180 max
Bot Window Trimmer b (in) = 1.5 d (in) = 5.5 Number I UNITY FAILED
M ft-# Unity DEFL in
MAX= I na I na na L/180 max
V1.14-12-2020
CASE 1 DL
CASE 2 DL + FLL
CASE 3 DL + RLL or SL
CASE 4 DL+0.75( FLL +(RLL or SL))
CASE 5a DL+0.6W
CASE 5b DL+0.7E
CASE 6a DL+0.75( FLL +0.6W + (RLL or SL))
CASE 6b DL+0.75( FLL + 0.7E + (RLL orSL))
CASE 7 0.6DL+ 0.6W
CASE 80.6DL+0.7E
TOP TRIMMER
CASE 1
16-8 DL
CASE 2
16-9 DL + FLL
CASE 3
16-10
DL + RLL or SL
CASE
16-11
DL + 0.75( FLL + (RLL orSL))
CASE 5a
16-12
DL+0.6W
CASE5b
16-12
DL+0.7E
CASE6a
16-13
DL + 0.75( FLL + 0.6W + (RLL orSL))
CASE6b
16-14
DL + 0.75( FLL + 0.7E + (RLL orSL))
CASE
16-15
0.6DL+0.6W
CASE
16-16
0.6DL+0.7E
BOT TRIMMER
CASE 1
16-8 DL
CASE 2
16-9 DL + FLL
CASE 3
16-10
DL + RLL or SL
CASE
16-11
DL + 0.75( FLL + (RLL orSL))
CASE 5a
16-12
DL+0.6W
CASE5b
16-12
DL+0.7E
CASE6a
16-13
DL + 0.75( FLL + 0.6W + (RLL orSL))
CASE6b
16-14
DL + 0.75( FLL + 0.7E + (RLL orSL))
CASE
16-15
0.6DL+0.6W
CASE
16-16
0.6DL+0.7E
RCR Engineers PLLC
29028 17th Ave SE
Kent, WA 98042
KING STUD
JACK STUD
MOM
AXIAL
UNITY
DER
MOM
AXIAL
UNITY
ASD
ASD
ASD
ASD
0
0
0.00
0.02
130
3120
0.32
0
0
0.00
0.02
303
7280
0.71
0
0
0.00
0.02
238
5720
0.47
0
0
0.00
0.02
24
585
0.05
1316
0
0.62
0.29
15
180
0.04
246
0
0.12
0.05
15
180
0.04
987
0
0.47
0.22
15
180
0.04
184
0
0.09
0.00
67
799
0.07
1316
0
0.62
0.00
9
108
0.02
246
0
0.12
0.05
5
54
0.01
MOM UNITY DER
ASD
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
31104
2.86
0.22
4838
2.86
0.03
23328
2.14
0.17
3629
0.33
0.03
31104
2.86
0.22
4838
0.44
0.03
MOM UNITY DER
ASD
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
24192
1.11
0.09
3763
0.17
0.01
18144
0.83
0.07
2822
0.13
0.01
24192
1.11
0.09
3763
0.17
0.01
Page 2
6/13/2022
RCR ENGINEERS. PLLC Structural EnLyineers
29028 176r" AVE SE, Kent, WA 98042 (206) 295 9439
Project# Project PAUL & NANCY TRIEU Date 3-19-2022
Subject LATERAL Sheet L-1
C
E
3.
C
C
E
BELOW ROOF
EQ = 6.1 K LRFD = 4.3K ASD
WIND NS = 7.3 K LRFD = 4.4K ASD
WIND EW = 6.OK LRFD = 3.6K ASD
On In n n n n
W'
tN'
tf
M
2.15 EQ/1.8 W ASD
� I
I
Cn
i
/
IC14_
N
w
• l/,
•
I
N
»
i
i
2.15 EQ/1.8 W AS
——
I
I
i
�
I
k
l
K K
I
N
K
N
I
BELOW ROOF
7
RCR ENGINEERS, PLLC Structural Engineers
Project#
Subject
29028 176r" AVE SE, Kent, WA 98042 (206) 295 9439
Project
PAUL & NANCY TRIEU
LATERAL
TOTAL BELOW 2ND
EQ = 10.5 K LRFD = 7.4K ASD
WIND NS = 17.6 K LRFD = 10.6K ASD
WIND EW = 14.2K LRFD = 8.5K ASD
BELOW 2ND / N
UPPER FLR
Date 3-19-2022
Sheet L-2
RCR ENGINEERS, PLLC Structural Engineers
Project#
Subject
Project
PAUL & NANCY TRIEU
LATERAL
29028 176r" AVE SE, Kent, WA 98042 (206) 295 9439
Date 3-19-2022
Sheet L-3
TOTAL BELOW MAIN
EQ = 10.5 K LRFD = 7.4K ASD + 4.4/2=2.2LRFD 1.5K ASD (BASEMENT)
WIND NS = 27.9 K LRFD = 16.7K ASD
WIND EW = 14.2K LRFD = 8.5K ASD + 2.6K LRFD /1.5K AT GRID B
BELOW MAIN TN
FLOOR
RCR ENGINEERS. PLLC Structural EnLyineers
29028 1761' AVE SE, Kent, WA 98042 (206) 295 9439
Project# Project PAUL & NANCY TRIEU Date 6-8-22
Subject LATERAL NORTH ELEVATION Sheet L-4
ACCUMULATED SHEARS
-----------
----------
LEIGHT
Mims
I
11r,
---- --- ----
mp
im:■
------------
R
age.
SHEARWALL SCHEDULE
WALL
END NAILING 11
MARK SHEATHING STUDS STUDS TOP PL SILL PL SHEATHING TOP PL BOT PL SILL PL TO FND
A % OSB
2X6@16
2-2X6
B % OSB
2X6@16
2-2X6
C % OSB
2X6@16
2-2X6
D % OSB
2X6@16
2-2X6
E % OSB
2X6@16*
2-2X6
* 3X6 @ PNLJT
** W/ 3X3X1/4 WASHER & EMBED 7"
1 NONE
2 MSTC28
3 MSTC40
4 MSTC52
5 MSTC66
6 DTTZ2
1/2" PAB4-8 ABolt
7 HDU2-SDS2.5
5/8" SSTB16 ABolt
8 HDU4-SDS2.5
5/8" SSTB16 ABolt
9 HDU5-SDS2.5
5/8" SSTB20 ABolt
10 HDU8-SDS2.5
7/8" SSTB28 ABolt
11 HDU11-SDS2.5
1" PA68-11 ABolt
2-2X6
2X6
8d@ 6/12 UNBLKD
16d@6
16d@6
5/8 AB @
48" OC**
2-2X6
2X6
8d@ 6/12 BLKD
16d@6
16d@6
5/8 AB @
48" OC**
2-2X6
2X6
8d@ 4/12 BLKD
16d@4
16d@4
5/8 AB @
24" OC**
2-2X6
2X6
8d@ 3/12 BLKD
16d@4
16d@4
5/8 AB @
24" OC**
2-2X6
2X6
8d@ 2/12 BLKD
16d@4
16d@4
5/8 AB @
24" OC**
1540#
3080#
4620#
5860#
2145#
3075#
4565#
5645#
6765#
9335#
NOTES:
1) SHEAR WALL CALLOUTS THUS A-2 A REFERENCES THE SHEATING AND NAILING, 2 REFERENCES THE HOLDOWN AND ANCHOR
2) ALL NAILS ARE COMMON SIZES
RCR Engineers PLLC
29028 176th Ave SE
Wood Panel Shearwall Page 1
V1.3 9-16-2020 6/8/2022
Based on SDPWS 4.3
P1(lbs) DL=
0
RLL=
0
LL=
0
SL=
0
"+ "WL=
0
"+-"EQ=
0
P1
NORTH ELEV BELOW ROOF 3.0+3.75+4+3.25=14.05FT
Forces
P2(lbs) DL=
RLL=
LL=
SL=
"+-"WL=
"+-"EQ=
from upper
levels ASD
w1 Trib(ft)= 10
DL(psf)= 15
RLL(psf)= 0
LL(psf)= 0
SL(psf)= 25
0
0
0
0
0
0
Wall DL(psf)= 10
P21 1 1 1 w1
Lf Opng (ft)= Wall Width(ft)= Rt Opng(ft)=
0 3 1
Shear ASD Input is plf
WL (plf) = 128
EQ (plf) = 154
Ht (ft)=
Wood Panel EF=Y/Nl NO
H/L = 3
H/L correction= 0.67
SILL= 2x V=
2X w/16d com V=187# T=105#
MAX SPACING 1 15 (in.)
Wood Panel t =17/16 Structural Panel
Nail Size =
8d Com / Galy Box 1 3/8 "pen
stud spacing(in)=
16
HD1
HD2
Stud material =
DF
Shear max left
1737
-166.5
Applied Lds
Shear min left
1368
1170
Nail Spacing=
6
V plf Total V
Shear max right
-166.5
1737
Allow Shear WL ASD=
335 plf
WL 128 384
Shear min right
-1170
1368
Allow Shear EQASD=
160 plf
EQ 1 154 1 462
* neg is uplift
LEFT HD
MSTC28 16"CLR 16-16d
- (1540#)
AB
NA
RIGHT HD
MSTC28 16"CLR 16-16d
- (1540#)
AB
NA
RCR Engineers PLLC
29028 176th Ave SE
Wood Panel Shearwall Page 1
V1.3 9-16-2020 6/8/2022
Based on SDPWS 4.3
P1(lbs) DL=
0
RLL=
0
LL=
0
SL=
0
"+ "WL=
0
"+-"EQ=
0
P1
NORTH ELEV BELOW 2ND 3.25+4.25+7=14.5FT
Forces
P2(lbs) DL=
RLL=
LL=
SL=
"+-"WL=
"+-"EQ=
from upper
levels ASD
w1 Trib(ft)= 10
DL(psf)= 15
RLL(psf)= 0
LL(psf)= 0
SL(psf)= 25
0
0
0
0
1170
1170
Wall DL(psf)= 10
P21 1 1 1 w1
Lf png (ft)= Wall Width(ft)= Rt Opng(ft)=
0 3.25 0
4 10
Shear ASD Input is plf
WL (plf) = 159
EQ (plf) = 127
Ht (ft)=
Wood Panel EF=Y/Nl NO
H/L = 2.7692
H/L correction= 0.72
SILL= 2x V=
2X w/16d com V=187# T=105#
MAX SPACING 1 14 (in.)
Wood Panel t =17/16 Structural Panel
Nail Size =
8d Com / Galy Box 1 3/8 "pen
stud spacing(in)=
16
HD1
HD2
Stud material =
DF
Shear max left
1828.9
-101.6
Applied Lds
Shear min left
1377
-2367
Nail Spacing=
6
V plf Total V
Shear max right
-979.1 �2835
Allow Shear WL ASD=
335 plf
WL 159 516.75
Shear min right
-1197
2490.4
Allow Shear EQASD=
1.333333333332
EQ 1 127 1 413
* neg is uplift
LEFT HD
MSTC40 16"CLR 48-16d
- (3080#)
AB
NA
RIGHT HD
MSTC40 16"CLR 48-16d
- (3080#)
AB
NA
RCR Engineers PLLC
29028 176th Ave SE
Wood Panel Shearwall Page 1
V1.3 9-16-2020 6/8/2022
Based on SDPWS 4.3
P1(lbs) DL=
0
RLL=
0
LL=
0
SL=
0
"+ "WL=
0
"+-"EQ=
0
P1
NORTH ELEV BELOW MAIN =7 FT
Forces
P2(lbs) DL=
RLL=
LL=
SL=
"+-"WL=
"+-"EQ=
from upper
levels ASD
w1 Trib(ft)= 10
DL(psf)= 15
RLL(psf)= 0
LL(psf)= 0
SL(psf)= 25
0
0
0
0
0
0
Wall DL(psf)= 10
P21 1 1 1 w1
Lf Opng (ft)= Wall Width(ft)= Rt Opng(ft)=
0 7 1
Shear ASD Input is total force #
W L # = 1917
EQ # = 1716
Ht (ft)=
Wood Panel EF=Y/Nl NO
H/L = 1.1429
H/L correction= 1.00
SILL= 2x V=
2x w/ 5/8DIA V=1235# T>1235#
MAX SPACING 54 (in.)
Wood Panel t =17/16 Structural Panel
Nail Size =
8d Com / Galy Box 1 3/8 "pen
stud spacing(in)=
16
HD1 HD2
Stud material =
DF
Shear max left 3235.6 121.64
Applied Lds
Shear min left 2444.1 -1708
Nail Spacing=
4
V plf Total V
Shear max right 121.64 �3235.6
Allow Shear WL ASD=
490 plf
WL 274 1917
Shear min right -1708 2444.1
Allow Shear EQASD=
350 plf
EQ 1 245 1 1716
* neg is uplift
LEFT HD
DTT2Z 1/2 AB 8-SDS1.5 1-STUD (1825#)
AB
NA
RIGHT HD
DTT2Z 1/2 AB 8-SDS1.5 1-STUD (1825#)
AB
NA
RCR Engineers PLLC FORCE TRANSFER SW
29028 176th Ave SE V1.3 9-16-2020
Based on SDPWS 4.3 & APA T555 WALL BELOW MAIN WEST 3.0+2.66 + 3.66+5.0 + 7 FT S
Uniform Load plf
trib ft = 10
DL= 0 DL= 12 DL= 0
RILL = 0 RILL = 0 RILL = 0
FILL = 0 FILL = 0 FILL = 0
SL= 0 SL= 25 SL= 0
"+-"WL= 0
Pleftl11+-"EQ= 0
H Dleft
Wall Wt psf = 10
"+-"WL = 0
"+-"EQ= 0 Pright
-----
I
-----------
------
-----
-----------
------
-----
------------------------
-----------
-----
Ht=
D righ
I H
width
hdr=
3.66
sill =
H/L = 0.82
WL # = 1552 ASD
EQ # = 1404 ASD
8 ftj
height *for 1 or 2 opng wall set remainder to zero
2.00 * 0.00 * 0.00
3.00 I 4.50 1 0.00 1 0.00 1 0.00 1 0.00 1 0.00 1 0.00 Ltotai ft = 14 ft
0.67
0.00 0.00
Wood Panel t =
Ea Face No
15/32 Structural Panel
Nail Size =
8d Com / Galy Box 13/8 "pen
stud spacing(in)=
16
Stud material =
DF
Nail Spacing =
4
Max Shear Applied
Shear Cap WL
314 plf
Wind
305 plf
Shear Cap EQ
224 plf
EQ
275 plf
HD1
HD2
Shear Left max =
3328
2029.9
Shear Left min =
1642
-89
Shear Right Mmax =
2030
3328
Shear Right Min =
-89
-89
* neg is uplift
Strap Force #
Wind 551.4 ICS20 12-8d 1030#
EQ 498.8 End Length (in) =1 6
SILL PLATE 2 x
FASTENER 2x w/5/8DIA V=1235# T>1235#
SPACING 49 (in.)
LEFT HD DTT2Z 1/2 AB 8-SDS1.5 1-STUD (1825#) AB - 5/8 SSTB16 6" STEM WALL 2550#
RIGHT HD DTT2Z 1/2 AB 8-SDS1.5 1-STUD (1825#) AB - 5/8 SSTB16 6" STEM WALL 2550#
Page 1
6/8/2022
RCR Engineers PLLC FORCE TRANSFER SW Page 2
29028 176th Ave SE V1.3 9-16-2020 6/8/2022
WIND / EQ EFFECTS
1) Shears Above & Below openings
Wind plf
First Opening 182
Second Opening 0
Third Opening 0
2) Total Boundary Force Above&Below Opng
Wind #
First Opening 1000
Second Opening 0
Third Opening 0
4) Tributary length of openings
Wind ft
First Opening Left
2.4669
First Opening Right
3.0331
Second Opening left
0
Second Opening Right
0
Third Opening left
0
Third Opening Right
0
6) Resistance to corner forces
Wind #
First Jamb
696
Second Jamb
856
Third Jamb
0
Fourth jamb
0
8) Unit shear in corner zone
wind pli
First Corner
68
Second Corner
68
Third Corner
1
Fourth Corner
1
EQ plf
164
0
0
EQ#
904
0
0
EQ ft
2.4669
3.0331
0
0
0
0
EQ#
630
774
0
0
EQ plf
61
61
1
1
3) Corner Forces -Strap Force
Wind #
First Opening Left
448.5
First Opening Right
551.4
Second Opening left
0
Second Opening Right
0
Third Opening left
0
Third Opening Right
0
5) Unit Shear beside openings
Wind plf
First Jamb
190
Second Jamb
190
Third Jamb
0
Fourth jamb
0
7) Difference of corner force and resistance
Wind #
First Jamb
248
Second Jamb
305
Third Jamb
0
Fourth jamb
0
EQ#
405.7
498.8
0
0
0
0
EQ plf
172
172
0
0
EQ#
224
275
0
0
RCR ENGINEERS, PLLC Structural Engineers
29028 176r" AVE SE, Kent, WA 98042 (206) 295 9439
Project# Project PAUL & NANCY TRIEU Date 6-8-22
Subject LATERAL WEST ELEVATION Sheet L-5
RODE
�EMxT
—
GNCK 8
Tr 6.101?
HEAOEff
a�
i
a'E1
L__Ju
TGE
2.15 EQ/2.2 W ASD
NEiGNr 1��'al�
E GF
ENTRY
TRUSS
f3.7 ESQ/5.3 WWAASD
� pr� I
-40
T N T B-2 (I I� I I I MEGNT
B-2 B-2 6-2I B-2
4.25 EQ/8.35 W ASD
B6 __.._.._.._.._..-.__------------------ - - - - --
._..
,i
--•
1 FGUR TIUN
A-2
A-2
EJSSST GFGUNWT To"E AS IS
RCR Engineers PLLC
29028 176th Ave SE
Wood Panel Shearwall Page 1
V1.3 9-16-2020 6/9/2022
Based on SDPWS 4.3
P1(lbs) DL=
0
RLL=
0
LL=
0
SL=
0
"+ "WL=
0
"+-"EQ=
0
P1
WEST ELEV BELOW ROOF 9+22=31FT
Forces
P2(lbs) DL=
RLL=
LL=
SL=
"+-"WL=
"+-"EQ=
from upper
levels ASD
w1 Trib(ft)= 6
DL(psf)= 15
RLL(psf)= 0
LL(psf)= 0
SL(psf)= 25
0
0
0
0
0
0
Wall DL(psf)= 10
P21 1 1 1 w1
Lf Opng (ft)= Wall Width(ft)= Rt Opng(ft)=
0 9 1
Shear ASD Input is plf
WL (plf) = 71
EQ (plf) = 69
Ht (ft)= 10
Wood Panel EF=Y/Nl NO
H/L = 1.1111
H/L correction= 1.00
SILL= 2x V=
2X w/16d com V=187# T=105#
MAX SPACING 32 (in.)
Wood Panel t =17/16 Structural Panel
Nail Size =
8d Com / Galy Box 1 3/8 "pen
stud spacing(in)=
16
HD1
HD2
Stud material =
DF
Shear max left
1995
945
Applied Lds
Shear min left
1203
-197
Nail Spacing=
6 unblkd
V plf Total V
Shear max right
945
1995
Allow Shear WL ASD=
201 plf
WL 71 639
Shear min right
-197
1203
Allow Shear EQASD=
144 plf
EQ 1 69 1 621
* neg is uplift
LEFT HD
MSTC28 16"CLR 16-16d
- (1540#)
AB
NA
RIGHT HD
MSTC28 16"CLR 16-16d
- (1540#)
AB
NA
RCR Engineers PLLC
29028 176th Ave SE
Wood Panel Shearwall Page 1
V1.3 9-16-2020 6/9/2022
Based on SDPWS 4.3
P1(lbs) DL=
0
RLL=
0
LL=
0
SL=
0
"+ "WL=
0
"+-"EQ=
0
P1
WEST WALL BELOW 2ND=7+7+7+5=26FT
Forces
P2(lbs) DL=
RLL=
LL=
SL=
"+-"WL=
"+-"EQ=
from upper
levels ASD
w1 Trib(ft)= 10
DL(psf)= 15
RLL(psf)= 0
LL(psf)= 0
SL(psf)= 25
0
0
0
0
0
0
Wall DL(psf)= 10
P21 1 1 1 w1
Lf Opng (ft)= Wall Width(ft)= Rt Opng(ft)=
0 5 1 1
Shear ASD Input is plf
WL (plf) = 203
EQ (plf) = 142
Ht (ft)=
Wood Panel EF=Y/Nl NO
H/L = 1.8
H/L correction= 1.00
SILL= 2x V=
2X w/16d com V=187# T=105#
MAX SPACING 1 11 (in.)
Wood Panel t =17/16 Structural Panel
Nail Size =
8d Com / Galy Box 1 3/8 "pen
stud spacing(in)=
16
HD1 HD2
Stud material =
DF
Shear max left 2532.8 204
Applied Lds
Shear min left 1638 -1467
Nail Spacing=
6
V plf Total V
Shear max right 204 2532.8
�1638
Allow Shear WL ASD=
335 plf
WL 203 1015
Shear min right -1467
Allow Shear EQASD=
240 plf
EQ 1 142 1 710
* neg is uplift
LEFT HD
MSTC28 16"CLR 16-16d - (1540#)
AB
NA
RIGHT HD
DTT2Z 1/2 AB 8-SDS1.5 1-STUD (1825#)
AB
NA
RCR Engineers PLLC
29028 176th Ave SE
Wood Panel Shearwall Page 1
V1.3 9-16-2020 4/2/2022
Based on SDPWS 4.3
P1(lbs) DL=
0
RLL=
0
LL=
0
SL=
0
"+ "WL=
0
"+-"EQ=
0
P1
EAST WALL BELOW MAIN=12.5+20FT
Forces
P2(lbs) DL=
RLL=
LL=
SL=
"+-"WL=
"+-"EQ=
from upper
levels ASD
w1 Trib(ft)= 10
DL(psf)= 15
RLL(psf)= 0
LL(psf)= 0
SL(psf)= 25
0
0
0
0
0
0
Wall DL(psf)= 10
P21 1 1 1 w1
Lf png (ft)= Wall Width(ft)= Rt Opng(ft)=
0 12.5 0
Shear ASD Input is plf
WL (plf) = 257
EQ (plf) = 131
Ht (ft)=
Wood Panel EF=Y/Nl NO
H/L = 0.24
HA correction= 1.00
SILL= 2x V=
2x w/ 5/8DIA V=1235# T>1235#
MAX SPACING 58 (in.)
Wood Panel t =17/16 Structural Panel
Nail Size =
8d Com / Galy Box 1 3/8 "pen
stud spacing(in)=
16
HD1 HD2
Stud material =
DF
Shear max left 3109.5 2236.5
Applied Lds
Shear min left 1068 -96
Nail Spacing=
6
V plf Total V
Shear max right 2236.5 3109.5
Allow Shear WL ASD=
335 plf
WL 257 3212.5
Shear min right -96 1068
Allow Shear EQASD=
240 plf
EQ 1 131 1 1638
* neg is uplift
LEFT HD
DTT2Z 1/2 AB 8-SDS1.5 1-STUD (1825#)
AB
NA
RIGHT HD
DTT2Z 1/2 AB 8-SDS1.5 1-STUD (1825#)
AB
NA
RCR ENGINEERS, PLLC Structural Engineers
29028 176r" AVE SE, Kent, WA 98042 (206) 295 9439
Project# Project PAUL & NANCY TRIEU Date 6-8-22
Subject LATERAL SOUTH ELEVATION Sheet L-6
d
e.aa�
HEIGHT
TOP OF d --
EHTRY
TRUSS
TOP OF -----
B•101lC
EIGHT
PV
•iu0E IE1WT
I 12
3-lw
B_2
B-2
I I I B-6
CRA- SPACE BEYOfO
51'-1P
1s-a- za ss
Ro
2.15 EQ/1.8 W ASD
ENM
-p- -
_-
��••==HEADER -TE
ssssssssesssssesssassssssssssassssss
CRA- SPACE BEYOND
.
•
BACK GARAGE
RCR Engineers PLLC
29028 176th Ave SE
Wood Panel Shearwall Page 1
V1.3 9-16-2020 4/2/2022
Based on SDPWS 4.3
P1(lbs) DL=
0
RLL=
0
LL=
0
SL=
0
"+ "WL=
0
"+-"EQ=
0
P1
SOUTH ELEV BELOW ROOF
Forces
P2(lbs) DL=
RLL=
LL=
SL=
"+-"WL=
"+-"EQ=
from upper
levels ASD
w1 Trib(ft)= 10
DL(psf)= 15
RLL(psf)= 0
LL(psf)= 0
SL(psf)= 25
0
0
0
0
0
0
Wall DL(psf)= 10
P21 1 1 1 w1
Lf png (ft)= Wall Width(ft)= Rt Opng(ft)=
0 3.5 1
Shear ASD Input is plf
WL (plf) = 128
EQ (plf) = 126
Ht (ft)= 10
Wood Panel EF=Y/Nl NO
H/L = 2.8571
H/L correction= 0.70
SILL= 2x V=
2X w/16d com V=187# T=105#
MAX SPACING 1 18 (in.)
Wood Panel t =17/16 Structural Panel
Nail Size =
8d Com / Galy Box 1 3/8 "pen
stud spacing(in)=
16
HD1 HD2
Stud material =
DF
Shear max left 1791.3 -113.8
Applied Lds
Shear min left 1522.5 -1018
Nail Spacing=
6
V plf Total V
Shear max right -113.8 �1791.3
Allow Shear WL ASD=
335 plf
WL 128 448
Shear min right -1018 1522.5
Allow Shear EQASD=
168 plf
EQ 1 126 1 441
* neg is uplift
LEFT HD
MSTC28 18"CLR 12-16d - (1155#)
AB
NA
RIGHT HD
MSTA49 18"CLR 26-10d-(2020#)
AB
NA
RCR Engineers PLLC
29028 176th Ave SE
Wood Panel Shearwall Page 1
V1.3 9-16-2020 4/2/2022
Based on SDPWS 4.3
P1(lbs) DL=
0
RLL=
0
LL=
0
SL=
0
"+_"WL=
0
"+-"EQ=
0
P1
SOUTH ELEV BELOW 2ND 3.0+3.0+10.0=16FT
Forces
P2(lbs) DL=
RLL=
LL=
SL=
"+-"WL=
"+-"EQ=
from upper
levels ASD
w1 Trib(ft)= 10
DL(psf)= 15
RLL(psf)= 0
LL(psf)= 0
SL(psf)= 25
0
0
0
0
0
0
Wall DL(psf)= 10
P21 1 1 1 w1
Lf png (ft)= Wall Width(ft)= Rt Opng(ft)=
0 3 1
Shear ASD Input is plf
WL (plf) = 144
EQ (plf) = 116
Ht (ft)=
Wood Panel EF=Y/Nl NO
H/L = 3
H/L correction= 0.67
SILL= 2x V=
2x w/ 5/8DIA V=1235# T>1235#
MAX SPACING 103 (in.)
Wood Panel t =17/16 Structural Panel
Nail Size =
8d Com / Galy Box 1 3/8 "pen
stud spacing(in)=
16
HD1 HD2
Stud material =
DF
Shear max left 1669.5 -85.5
Applied Lds
Shear min left 1260 -1080
Nail Spacing=
6
V plf Total V
Shear max right -85.5 1669.5
�1260
Allow Shear WL ASD=
335 plf
WL 144 432
Shear min right -1080
Allow Shear EQASD=
160 plf
EQ 1 116 1 348
* neg is uplift
LEFT HD
DTT2Z 1/2 AB 8-SDS1.5 1-STUD (1825#)
AB
NA
RIGHT HD
DTT2Z 1/2 AB 8-SDS1.5 1-STUD (1825#)
AB
NA
RCR Engineers PLLC
29028 176th Ave SE
Wood Panel Shearwall Page 1
V1.3 9-16-2020 4/2/2022
Based on SDPWS 4.3
P1(lbs) DL=
0
RLL=
0
LL=
0
SL=
0
"+_"WL=
0
"+-"EQ=
0
P1
BACK GARAGE BELOW 2ND=16.5FT
Forces
P2(lbs) DL=
RLL=
LL=
SL=
"+-"WL=
"+-"EQ=
from upper
levels ASD
w1 Trib(ft)= 10
DL(psf)= 15
RLL(psf)= 0
LL(psf)= 0
SL(psf)= 25
0
0
0
0
0
0
Wall DL(psf)= 10
P21 1 1 1 w1
Lf png (ft)= Wall Width(ft)= Rt Opng(ft)=
0 16.5 0
Shear ASD Input is plf
WL (plf) = 258
EQ (plf) = 224
Ht (ft)=
Wood Panel EF=Y/Nl NO
H/L = 0.5455
H/L correction= 1.00
SILL= 2x V=
2x w/ 5/8DIA V=1235# T>1235#
MAX SPACING 57 (in.)
Wood Panel t =17/16 Structural Panel
Nail Size =
8d Com / Galy Box 1 3/8 "pen
stud spacing(in)=
16
HD1 HD2
Stud material =
DF
Shear max left 5577.8 2324.3
Applied Lds
Shear min left 3204 -1134
Nail Spacing=
6
V plf Total V
Shear max right 2324.3 5577.8
Allow Shear WL ASD=
335 plf
WL 258 4257
Shear min right -1134 3204
Allow Shear EQASD=
240 plf
EQ 1 224 1 3696
* neg is uplift
LEFT HD
DTT2Z 1/2 AB 8-SDS1.5 1-STUD (1825#)
AB
NA
RIGHT HD
DTT2Z 1/2 AB 8-SDS1.5 1-STUD (1825#)
AB
NA
RCR ENGINEERS, PLLC Structural Engineers
29028 176r" AVE SE, Kent, WA 98042 (206) 295 9439
Project# Project PAUL & NANCY TRIEU Date 6-8-22
Subject LATERAL EAST ELEVATION Sheet L-7
YOGE
Tsa-
11�-0'1 HEIGHT
ENTRY
TRUSS
vral _
TOP OF 6-t--
HEADER
MIGHT
va-
la•o•I
W.
A-6
r1
I �
EXISTING FOUNDATION TO REAW/ AS IS
C• J-I• S-r " I rw
A
------------------ram
2.15 EQ/2.2 W ASD
1SJ
nG"T
3.7 EQ/5.3 W ASD
B.tO 12• TOP OF
-__ N+LTE
EAD6t
HMGM
4.25 EQ/8.35 W ASD
mrn HDAIf
(d-0•I
RCR Engineers PLLC
29028 176th Ave SE
Wood Panel Shearwall Page 1
V1.3 9-16-2020 6/9/2022
Based on SDPWS 4.3
P1(lbs) DL=
0
RLL=
0
LL=
0
SL=
0
"+ "WL=
0
"+-"EQ=
0
P1
EAST ELEV BELOW ROOF 4.5+9+4.5=18FT
Forces
P2(lbs) DL=
RLL=
LL=
SL=
"+-"WL=
"+-"EQ=
from upper
levels ASD
w1 Trib(ft)= 10
DL(psf)= 15
RLL(psf)= 0
LL(psf)= 0
SL(psf)= 25
0
0
0
0
0
0
Wall DL(psf)= 10
P21 1 1 1 w1
Lf Opng (ft)= Wall Width(ft)= Rt Opng(ft)=
0 21 1
Shear ASD Input is plf
WL (plf) = 122
_]
EQ (plf) = 119
Ht (ft)= 10
Wood Panel EF=Y/Nl NO
H/L = 0.4762
H/L correction= 1.00
SILL= 2x V=
2X w/16d com V=187# T=105#
MAX SPACING 1 18 (in.)
Wood Panel t =17/16 Structural Panel
Nail Size =
8d Com / Galy Box 1 3/8 "pen
stud spacing(in)=
16
HD1 HD2
Stud material =
DF
Shear max left
5902.5 4095
Applied Lds
Shear min left
2765 355
Nail Spacing=
6 unblkd
V plf Total V
Shear max right
4095 5902.5
Allow Shear WL ASD=
201 plf
WL 122 2562
Shear min right
355 2765
Allow Shear EQASD=
144 plf
EQ 1 119 1 2499
* neg is uplift
LEFT HD
NONE REQUIRED
AB
NA
RIGHT HD
NONE REQUIRED
AB
NA
RCR Engineers PLLC
29028 176th Ave SE
Wood Panel Shearwall Page 1
V1.3 9-16-2020 4/2/2022
Based on SDPWS 4.3
P1(lbs) DL=
0
RLL=
0
LL=
0
SL=
0
"+ "WL=
0
"+-"EQ=
0
P1
EAST WALL BELOW 2ND=22.5+5+6+5=38.5FT
Forces
P2(lbs) DL=
RLL=
LL=
SL=
"+-"WL=
"+-"EQ=
from upper
levels ASD
w1 Trib(ft)= 10
DL(psf)= 15
RLL(psf)= 0
LL(psf)= 0
SL(psf)= 25
0
0
0
0
0
0
Wall DL(psf)= 10
P21 1 1 1 w1
Lf Opng (ft)= Wall Width(ft)= Rt Opng(ft)=
0 j 1 5 j 10
Shear ASD Input is plf
WL (plf) = 145
EQ (plf) = 101
Ht (ft)=
Wood Panel EF=Y/Nl NO
H/L = 1.8
H/L correction= 1.00
SILL= 2x V=
2x w/ 5/8DIA V=1235# T>1235#
MAX SPACING 102 (in.)
Wood Panel t =17/16 Structural Panel
Nail Size =
8d Com / Galy Box 1 3/8 "pen
stud spacing(in)=
16
HD1 HD2
Stud material =
DF
Shear max left 2141.3 480.75
Applied Lds
Shear min left 1269 -945
Nail Spacing=
6 unblkd
V plf Total V
Shear max right 480.75 2141.3
Allow Shear WL ASD=
201 plf
WL 145 725
Shear min right -945 1269
Allow Shear EQASD=
144 plf
EQ 1 101 1 505
* neg is uplift
LEFT HD
DTT2Z 1/2 AB 8-SDS1.5 1-STUD (1825#)
AB
NA
RIGHT HD
MSTC28 18"CLR 12-16d - (1155#)
AB
NA
RCR Engineers PLLC
29028 176th Ave SE
Wood Panel Shearwall Page 1
V1.3 9-16-2020 4/2/2022
Based on SDPWS 4.3
P1(lbs) DL=
0
RLL=
0
LL=
0
SL=
0
"+ "WL=
0
"+-"EQ=
0
P1
EAST WALL BELOW MAIN=22.5FT
Forces
P2(lbs) DL=
RLL=
LL=
SL=
"+-"WL=
"+-"EQ=
from upper
levels ASD
w1 Trib(ft)= 10
DL(psf)= 15
RLL(psf)= 0
LL(psf)= 0
SL(psf)= 25
0
0
0
0
0
0
Wall DL(psf)= 10
P21 1 1 1 w1
Lf Opng (ft)= Wall Width(ft)= Rt Opng(ft)=
22.5 10
Shear ASD Input is plf
WL (plf) = 160
EQ (plf) = 82
Ht (ft)=
Wood Panel EF=Y/Nl NO
H/L = 0.1778
H/L correction= 1.00
SILL= 2x V=
2x w/ 5/8DIA V=1235# T>1235#
MAX SPACING 93 (in.)
Wood Panel t =17/16 Structural Panel
Nail Size =
8d Com / Galy Box 1 3/8 "pen
stud spacing(in)=
16
HD1 HD2
Stud material =
DF
Shear max left
5148.8 4422.8
Applied Lds
Shear min left
1610.5 643
Nail Spacing=
6 unblkd
V plf Total V
Shear max right
4422.8 5148.8
Allow Shear WL ASD=
201 plf
WL 160 3600
Shear min right
643 1610.5
Allow Shear EQASD=
144 plf
EQ 1 82 1 1845
* neg is uplift
LEFT HD
NONE REQUIRED
AB
NA
RIGHT HD
NONE REQUIRED
AB
NA