Loading...
REVIEWED BLD2023-1264+GATE INFO+10.10.2023_4.17.26_PM+3833164A1��X SlJl�CR � RAf 2300 Moves heavy gates up to 20' High -traffic, High -wind Self-locking, Mag Lock unnecessary Overload clutch release on 3-ton impact • 1 MAX SURER ARM ;0 00 FEATURE LIST: Gate Capacity _ 1=� Max Weight/ 0 .o_ L_�_ — Min = 37" Length 9.25" :o - Max = 54.75" 4.5 t A.-- _' 8ft 12ft 16ft 20ft • Shipping weight of Actuator: Super Arrn (35 Ibs) • Shipping w--ight Df AC Control Box (38 Ibs) (D 1 he patented brake system allows the operator to retract wit i ext 'eme `once. Whey ; the �)rce exceeds 3 tons. the clutch releases upon impact, Shen automatically resets. Causes for c!.itch release include a vehicle strike while the gate is in motion. • Stainless steel output shaft • Direct gear drive [no internal chains, belts, or pulleys) • Mechanical and electrical gate release functions • Continuous duty cycle at extreme temperature range. No ovei,heating • Intelligent ramp -up and ramp -down for smooth gate operation • 24 Volt DC motor • Two independently ad;ustable closing speed controls wit i 16 ;:iositi: ins each • Switchable 115,.'230 voltage selection Adaptive DSP motor control for advanced motion control • Real time performance analyzer and event log [OBD PORT and Black Box] • Magic Box enables low voltage wiring capabilities for remote power up to 1000 ft • On -board switch for solar mode enables 5 milliamp idle in sleep mode • Gold contact input connections and automobile grade connec- ors • -4F to 165F (-20C to +74C) operational range including battery backup without a heater 0 = Unique to Max Super Arm 2300 Al r K-Xt f = • Robust lightning protection, up to 20KVolts and 1 OKAmps on all inputs and outputs (35 channels) including loop detector input connections • Two selectable 16 position safety obstruction sensors, auto adaptable to gate weight anc; size. for independent control of open and close cycles 15 Independent closing speeds for primary and secondary • Dual motor overcurrent safety shut off for additional protection • Two lamp hour batteries provide 50D cycles in case of power failure with three modes of battery backup, open once, leave open or leave closed • On -board three button station • On -board UL reset button S.-iCURI , -Y 5PEC:lFICA, 10; 4c; • High traffic intuitive loop management system for exceptional security • Advanced security features with built-in audible and remote alarms • Magnetic lock control relay outputs with selectable delay times • Tamper alert relay output triggers "on" if gate is forced open • Audible alarm if gate is tampered with or ERD is triggered for heightened security • Steel cover with lock protects against intruders and vandalism • Gate disable feature disables all inputs with exception of the fire department and Max Open input for increased security • Built in transaction buffer • Gate status outputs for gate monitoring • Key activated jog function for emergency OPEN/CLOSE function • Advanced anti -tailgate feature prevents unwanted intrusion c i-AF'E, Ti 'Y SPECIFICATION-Ey • UL 325/991 compliant Class I, Il, III, and IV. CSA approved i* Vehicle hit protection technology protects the gate operator from collision damage caused by automobile impact, avoiding costly repairs • Built in advanced entrapment protection and alarm output • Built in gate -in -motion alarm for industrial applications = Unique to Max Super Arm 2300 The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the hood. To engage the actuator, push down the hood and lock to resume automatic operation. Fron- Bracket The Max Super Arm 2300 ships with a heavy d.ity half inch stock rear bracket that is broached and welded. Both brackets front and rear, are silver zinc plated. Rear Bracket Maximum Controls recognizes swing gates are more prone to vehicular collisions. For this reason, the Max Super Arm 2300 will collapse on impact when struck by vehicular traffic. When a vehicle hits a moving gate, to avoid damage to the actuators, the Super Arm 2300 reset automatically. DULL OPEN INSIDE PROPERTY ' CLOSED 1 OPEN "' OPEN CLOSED PUSH OPEN OUTSIDE PROPERTY OPENING ONE 90° AND THE OTHER IS 75' r, r� 1r I1 r l �l r I r r r r 900OPEN 750OPEN - Y . For asymmetric installations the two independent closing speeds can be adjusted to achieve a smooth closing sync. Whichever gate closes first, slow it down. This enables the installer to visually sync the closing cycle. This feature is unique to Maximum Control's actuators. i l' i 1' 900 OPEN �77- WITH THE INDEPENDENT CLOSING SPEEDS ADJUSTED r ' THE CLOSING GATE LEAVES CAN BE SYNCED l % f , ;rr I Y O 75 OPEN Steel housing 2- layer protection Gold zinc Electrostatic powder coating Gold plated automobile connectors throughout the system Loop Rack Two plugin ON and OFF Safety Loop power outlets Power S_ipply Center Loop Switch Exit Loop Control Panel Two 12V 7 AGM Batteries . UL Reset Button . Jog Open,Close Key Switch for emergency access to property Selectable Switch 115V or 230V AC imp se The AC Control Box features rugged metal construction that is gold zinc plated and powder coated. Each AC Control Box comes with an exterior UL reset button, a convenient jog key switch for emergency access or egress, a 10 amp power supply with two 115 VAC accessory outlets, two 7 amp batteries conveniently located behind the control panel, a loop rack and much more. A lockable steel cover finishes off this slick design. A convenient LCD display keeps you informed. Functional data and error messages are visible when an accessory failure or function is present. This makes troubleshooting and monitoring a breeze. These many features can be explored in our downloadable installation manual available on max.us.com Steel housinc 2-layer protectior Gold zinc Electrostatic powder coatinc Gold pl automobile connei through the sy! Loop Rack OPTIONAL ON and OFF Solar Regulator Power Supply Switch 24V,10A (MORNING STAR) 30A FUSE Control Panel "wo 12V 13 Agm Batteries UL Reset Button log Switch input )PTIONAL iolar Regulator !4V, 10A MORNING STAR) ,� .- ,,�,�► .n: ;,�,x- �- :s .r� m ^' rt • it 1. Battery Backup Mode Switch 8. Solar Mode Application 2. Battery Test Switch 9. Motion Control Buttons 3. ERD Sensitivity 10. Maglock Delay 4. OBD Port 11. LCD Display 5. DIP Switches 12. Close Timer Switch 6. Program Button 13. Jog Open,"Close 7. Loop Status 14. Closing Gate Speed 1. Battery Input 5. UL Alarm 2. Power/Solar Input 6. ID Plug 3. Module Port 7. Loop Rack Input 4. Reset 8. 12VOC & 24VOC Limited Current Power Output Steel housing 2-layer protection Gold zinc Electrostatic powder coating Gold plated automobile connectors through the system SOLAR MODE Switch to enable low power draw for solar mode Wire solar panel terminals to solar regulator input Caution: polarity matters ON and OFF Solar Regulator Power Supply Switch 24V, 10A (MORNING STAR) Two 12V 18 AH (AGM Rechargable Batteries) . UL Reset Button Jog Switch OPTIONAL Solar Regulator 24V, 10A (MORNING STAR) 24V Solar Panel Output: 36 V (Max) - Open Circuit Select proper solar panel I-_Aal System. Currenl Draw (.,A) 26 50 60 W 100 200 250 26 50 85 W 100 200 250 26 50 120 W 100 200 250 26 50 200 W 100 200 250 SWING, ACTUATOR GATE SOLAR CYCLES PER DAY ZONE (6 Hrs Sunlight/Day) 18Ah 18Ah BATTERIES BATTERIES 442.74 438.58 408.16 400.16 336.13 32033 192.08 160.06 120.05 80.03 442.74 438.58 40836 400.16 336.13 320.13 192.08 160.06 120.05 80.03 442.74 438.58 408.16 40036 336.13 320.13 192.08 160.06 12005 80.03 442.74 43858 408.16 400.16 33633 320.13 19208 160.06 120.05 80.03 The map and daily cycle rate shown are approximations based upon the average solar radiation and the temperature effects on batteries in the given regions. Local geography and weather conditions ma,,l require additional solar paneis. USE LOW POWER accessories in order to minimize power draw. Each additional accessory draws power affecting the daily cycle rate. The Max Super Arm 2300 offers the most robust lightning protection available in the industry. The Super Arm protects all peripheral inputs, loop inputs, power inputs, relay outputs, and all communication lines (over 35 channels of protection) in 1/1,000,000,000 of a second. With special emphasis on power supply protection, the Max Super Arm 2300 is guaranteed to withstand any lightning hiz more than 50 feet away. Truly protected like no other operator in the world. Maximum Controls LLC Warranty and Return Policy Section 1 Coverage a. 2 years or 100,000 cycles whichever comes first on components b.1 year on batteries iection 11 Not Covered a. Damages due to flooding b. Damages due to fire c. Damages due to negligence i.e. leaving the cover off in the rain, improper wiring of AC or peripheral systems d. Damages due to product misuse i.e. gate and operator combination mismatch e. Damages due to vandalism Section ii..-vivop% whipping Policy a. Maximum Controls LLC will pay for return shipping via standard ground UPS or USPS FOB CA on all BMA's within one year of Distributor's purchase b. Any form of "Expedited Shipping" on any RMA will be paid by Distributor -section IV Product Return! a Products must be in original, resalable condition with all warranty information, manuals, and original packaging. b. A re -stock fee of 10% will be charged on all returned products. c. All returned products must reference a Maximum Controls RMA number or it will be refused. d. Maximum Controls is not responsible for freight charges associated with returned merchandise. Fountain Valley CA 92708 nnximum MAX www.Max.US.com iLL MaxiMUil-I Go Aroh Distr butc:irs & C ea:E Independent Dealer or D stributor Rev. MAY-2020