APPROVED PLN BLD FIR RESUB 3-SM PLAN SHEETS-BLD2023-0778-9.7.23GENERAL NOTES: 1. ALL CONSTRUCTION FOR UNIRAC'S 'ROOF MOUNT' (RM) RACKING SYSTEM SHALL CONFORM TO THE CODES SHOWN IN THE RM DESIGN CRITERIA TABLE BELOW. LOCAL JURISDICTION AMENDMENTS TO THE CODE MUST BE TAKEN INTO CONSIDERATION. 2. WHENEVER THE TERM "CONTRACTOR" IS USED IN THE CONSTRUCTION DOCUMENT, IT SHALL BE DEFINED TO MEAN THE GENERAL CONTRACTOR AND ANY SUB -CONTRACTOR COLLECTIVELY AS APPLICABLE AND AS REQUIRED. 3. THE CONTRACT "STRUCTURAL RACKING" DRAWINGS REPRESENT THE FINISHED STRUCTURE. UNIRAC AND THE ENGINEER OF RECORD WILL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES OF CONSTRUCTION. 4. UNIRAC AND THE ENGINEER OF RECORD WILL NOT BE RESPONSIBLE FOR CONSTRUCTION SITE SAFETY OR SAFETY PRECAUTIONS AND PROGRAMS INCIDENT HERETO. 5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT AND ENSURE THAT ALL WORK IS IN CONFORMANCE WITH THE CONTRACT DOCUMENTS. ANY STRUCTURAL INSPECTION/OBSERVATION PROVIDED BY OTHERS (INCLUDING UNIRAC AND THE ENGINEER OF RECORD) DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY. ANY DEVIATION FROM THE CONTRACT DOCUMENTS THAT IS ENCOUNTERED AT A LATER DATE AND IS DECLARED TO BE SIGNIFICANT BY UNIRAC AND THE ENGINEER OF RECORD SHALL BE CORRECTED BY THE CONTRACTOR (AT THE CONTRACTOR'S EXPENSE). ANY INDIVIDUALS FROM UNIRAC OR THE ENGINEER OF RECORD'S OFFICE PERFORMING SITE VISITS OR STRUCTURAL OBSERVATIONS ARE NOT AUTHORIZED TO DIRECT OR APPROVE ANY CHANGES FROM THE CONTRACT DOCUMENTS OR STOP AND/OR DELAY THE WORK. 6. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND COORDINATE SITE CONDITIONS WITH THE DRAWING PRIOR TO BIDDING AND THE START OF CONSTRUCTION. ANY CONFLICTS, DISCREPANCIES, OR OMISSIONS SHALL BE RESOLVED WITH UNIRAC AND THE ENGINEER OF RECORD PRIOR TO PROCEEDING. DO NOT SCALE DIMENSIONS FROM DRAWINGS. WRITTEN DIMENSIONS SHALL BE USED OR WHERE NO DIMENSION IS PROVIDED. CONSULT WITH UNIRAC FOR CLARIFICATION BEFORE PROCEEDING. 7. WHERE ANY DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER (MOST CONSERVATIVE) REQUIREMENTS SHALL GOVERN. WHERE NO SPECIFIC DETAIL IS SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. IF THERE IS NO SIMILAR WORK CONSTRUCTION SHALL CONFORM TO INDUSTRY STANDARDS. CONTRACTOR MUST INFORM UNIRAC OF ANY DISCREPANCIES. 8. ANY EQUIPMENT OR CONDUIT BEING SUPPORTED BY OR SUSPENDED FROM THE RACKING STRUCTURE SHALL BE COORDINATED WITH UNIRAC AND THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO PURCHASE AND INSTALLATION OF EQUIPMENT OR CONDUIT. 9. ASTM SPECIFICATIONS ON THE DRAWINGS SHALL BE OF THE LATEST ASTM STANDARD SPECIFICATION OR ASTM STANDARD ADOPTED BY THE SITE JURISDICTION. :!W X, %. r_ !-. - - mw'ffs r,J,A a. 250 5TH AV E N EDMONDS, WA 98020 10. ANY ENGINEERING DESIGN PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW SHALL BEAR THE SEAL OF A PROFESSIONAL CIVIL OR STRUCTURAL ENGINEER REGISTERED IN THE STATE OF THE LOCAL JURISDICTION. 11. THE FOLLOWING DESIGN CRITERIA IS EXCLUDED FROM DESIGN: FLOOD LOADING, DEBRIS LOADING, DYNAMIC ANALYSIS, ACTS OF GOD (TORNADO, HURRICANE, WATER INUNDATION LOADING, ETC.), AND DYNAMIC LOADING FROM SEISMIC EVENTS AND CONDITIONS. 12. THE MINIMUM DISTANCE BETWEEN ROOF EDGE AND MODULES OR RM RACKING SYSTEM MUST BE 4 FT UNLESS NOTED OTHERWISE IN THE UNIRAC ENGINEERING REPORT. 13. UNIRAC IS NOT RESPONSIBLE FOR THE ORIGINAL BUILDING STRUCTURE. CONSULT WITH A LICENSED PROFESSIONAL ENGINEER IN THE JURISDICTION OF THE PROJECT TO ENSURE THE EXISTING BUILDING IS CAPABLE OF HANDLING ADDITIONAL LOAD FROM THE RM STRUCTURE. 14. IN THE EVENT THAT THE ARRAY IS DISPLACED FOR ANY REASON, THE ARRAY SHALL BE REPOSITIONED INTO ITS ORIGINAL DESIGN LOCATION SO AS TO ENSURE THAT PROPER SEISMIC AND FIREFIGHTING ACCESS CLEARANCES AND SEPARATIONS ARE MAINTAINED, IN ADDITION TO ELECTRICAL WIRING SEISMIC SLACK REQUIREMENTS. 15. THESE GENERAL NOTES APPLY TO ALL SHEETS IN THIS PACKAGE. SOLAR DESIGN: UNIRAC IS NOT THE SOLAR DESIGN ENGINEER OF RECORD AND IS NOT RESPONSIBLE FOR ANY SOLAR DESIGN, OUTPUT EFFICIENCIES, SHADING, ETC. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO CONFIRM THAT THE LOCATION OF THE RACKING/MODULES DOES NOT INTERFERE WITH OR BECOME SHADED BY OBSTRUCTIONS. ELECTRICAL DESIGN: UNIRAC IS NOT THE ELECTRICAL ENGINEER OF RECORD AND IS NOT RESPONSIBLE FOR THE ELECTRICAL DESIGN FOR THIS PROJECT. THE UNIRAC SYSTEM IS CERTIFIED TO UL-2703 WHEN PROPERLY INSTALLED. SEE THE RM INSTALLATION GUIDE FOR MORE DETAIL. MATERIAL MANAGEMENT: 1. PRIOR TO INSTALLATION, ALL MATERIALS MUST BE STORED PROPERLY. THIS MEANS MATERIALS REMAINING IN ONE PLACE FOR MORE THAN ONE WEEK MUST BE IN OPEN AIR CONDITIONS (I.E. UP AND ABOVE THE GROUND AND WATER TABLE). IF TARPS OR OTHER PROTECTIVE COVERS ARE USED, THEN ENDS SHALL BE LEFT OPEN FOR VENTILATION. TIGHT FITTING COVERINGS ARE NOT RECOMMENDED SINCE THEY CAN TRAP MOISTURE. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND PROVIDE ALL MEASURES NECESSARY TO PROTECT THE RACKING SYSTEM FROM THE POINT OF UNIRAC DELIVERY THROUGHOUT THE 3. COMPLETION OF CONSTRUCTION. APPROVED BY PLANNING ��a"10�_ Sep 08 2023 PROVED PLANS MUST BE ON JOB SITE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES RM ALUMINUM COMPONENTS: 1. ALL ALUMINUM RM BAY MEMBERS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE 112010 ALUMINUM DESIGN MANUAL" BY THE ALUMINUM DESIGN ASSOCIATION. 2. ALL ALUMINUM BAY MEMBERS SHALL CONFORM TO ONE OF THE FOLLOWING: SKI MATERIAL: ALLOY: 6063 TEMPER 5 (Ftu = 38 KSI, Fcy = 35 KSI) SKI MATERIAL: ALLOY: 6105 TEMPER 52 (Ftu = 38 KSI, Fcy = 35 KSI) DOWEL MATERIAL: ALLOY: 6063 TEMPER 5 (Ftu = 38 KSI, Fcy = 35 KSI) CLAMP MATERIAL: ALLOY: 6005A TEMPER 61 (Ftu = 38 KSI, Fcy = 35 KSI) HARDWARE: 1. 3/8"-16 X 1-3/4" UNC 2A HARDWARE SHALL CONFORM TO 18/8 STAINLESS STEEL (AISI 300 SERIES), DIMENSIONS PER ASME 1318.2.1. TORQUE REQUIREMENTS 3/8" 0 HARDWARE = 8 +/-1 FT-LBS SINGLE USE ONLY- DO NOT RE -TORQUE ONCE FULLY SEATED BALLAST BLOCK (CMU): 1. INSTALLER IS RESPONSIBLE FOR PROCURING THE BALLAST BLOCKS (CMU) AND VERIFYING THE REQUIRED MINIMUM WEIGHT NEEDED FOR THIS DESIGN. CMU TO COMPLY WITH ASTM STANDARD SPECIFICATION FOR CONCRETE ROOF PAVERS DESIGNATION C1491-14 or C90-16a FOR A "NORMAL WEIGHT" DENSITY CLASSIFICATION WITH A COMPRESSIVE STRENGTH OF 3000 PSI. IT IS RECOMMENDED THAT THE BLOCKS ARE INSPECTED PERIODICALLY FOR ANY SIGNS OF DEGRADATION. 2. ACTUAL BLOCK DIMENSIONS ARE 3/8" LESS THAN NOMINAL DIMENSIONS. DESIGN CRITERIA BUILDING CODE ASCE 7-16 OCCUPANCY/RISK CATEGORY WIND SPEED (MPH) II 100 WIND EXPOSURE B GROUND SNOW LOAD (PSF) 25 ROOF HEIGHT (FT) 25 ROOF PITCH 140 MAXIMUM JOINT REACTIONS FACTORED LOADS ASD ASCE 7-16 ZONE 1 ZONE 2 ZONE 3 UPLIFT POINT LOAD -384.0 LB -537.4 LB -647.1 LB DOWN POINT LOAD 369.4 LB 369.4 LB 369.4 LB Zone ------------ Corner :_____ Flag Setbacks: Required Actual Front ' Sides ___________- Rear Other Height 25 ___ 25 Approved DFM Ohr%s Burt South County Fire Date: 09/08/2023 09-08-2023 APPROVED WITH CONDITIONS: 1. PROVIDE SIGNAGE WHERE RAPID SHUT DOWN IS PROVIDE AS NOTED IN 2018 WA STATE ADOPTED IFC SECTION 1204.5. DFM BURT City Of Edmonds Building Department ..... ........................� Work ROOFTOP SOLAR ................................................................................. Address 250 5TH AVE N .L.• .........................• Owner PUBLIC SAFETY BLDG Approved Date Building Official Permit Number 9/08/2023 BLD2023-0778 PROJECT OVERVIEW PROJECT SIZE (KW DC) 128.52 MODULE QUANTITY 238 MODULE SPECIFICATIONS MANUFACTURER JA SOLAR MODEL JAM72D30-540/MB LENGTH (IN) 89.96 WIDTH (IN) 44.64 FRAME THICKNESS (IN) 1.38 69.67 WEIGHT (LBS) OUTPUT (W) 540 ENGINEERING OUTPUT - SM PRODUCT LINE SOLARMOUNT CLAMP TYPE PRO CLAMP RAIL DIRECTION EW ROOF TYPE STANDING SEAM METAL TOTAL WEIGHT (LBS) 18382.24 MAXIMUM RAIL SPAN (IN) 72 RAIL SPAN USED FOR THIS DESIGN (IN) 72 MAX CANTILEVER AT DESIGN SPAN (IN) 24 ARRAY PARTS LIST - SM PART NUMBER DESCRIPTION QUANTITY 320246M SM RAIL 246" MILL 150 303019M BND SPLICE BAR PRO SERIES MILL 78 302030M SM PRO SERIES MID - MILL 621 302035M SM PRO SERIES UNIV END - MILL 186 004130M STANDING SEAM CLAMP, MINI 1SS L-FOOT SERRATED W/ T-BOLT, CLR ILSCO LAY IN LUG (GBL4DBT) 678 304001 C 008009P 678 31 SHEET INDEX SM.100 COVER SHEET SM.200 KEY PLAN SM.301-SM.302 ARRAY LAYOUT ROOF AREA 1 TO 2 SM.400 SM DETAILS SM.500 ATTACHMENT DETAILS .. (N O W 00 zQ U) > 0 Jv0 Q m Q�z W z � Q Q W O m ry W .. 0 m MINI Q ENGINEER'S STAMP • � c _fI 01 z. Q '•,'Q�G 1947TV ��0, �SIDNAL�'�� 07-S E P-2023 EXP.:15-DEC-2023 FOR PV RACKING ONLY Y U z z z z z , 3: > > > Y w c� Q U z O_ CO ��w� z O � fn � ° o Lu z Q w w D o o w o o W w 0 Q (n w Q Ln p z 0 N N N N N 0 0 0 0 0 Q CNN 0 It 0 19t 0 LO 0 I- 0 FOR MCKINSTRY PROJECT CITY OF EDMONDS PUBLIC SAFETY 250 5TH AVE N EDMONDS, WA 98020 TITLE COVER RESUB SHEET Sep 07 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET sm. 100 F� W �0 �7 0 > -n D z O 0 ��Xmn � 0 H12�ON m°0, -0 n1 Dmo O '^ Ago � V) v) 2!M0 <z O T J <0 r.') W mW r m _ C) � o REVISIONS z O m m m O � REV DATE DESCRIPTION DRW CHK G) R p n 0 02/08/2023 INITIAL RELEASE MT NT z . V J m iv o o ....... m 1 O cn - 1 04/14/2023 REVISED THE LAYOUT BV NT m : man I'RAC \ z o rr 7rjO 2 04/21/2023 MODULES RE -ALIGNED BV NT .y.••'�i'� STgr�d `J Du'm ZQ�(�� fit° �: � = m z 3 05/23/2023 CHANGED THE MODULE WATTAGE BV NT 0 �° �`• • • 9 N D D o � z� 2' OVA, ���.i D - 0 r m 4 07/19/2023 ADDED LAYOUT DIMENSION UK NT o o w 2G0 Noy`?':'• O D o z m O _ _ _ _ _ �...... 1411 BROADWAY BOULEVARD NE z o � zz _ _ _ _ _ ALBUQUERQUE, NEW MEXICO, USA, 87102 cn - - - - - WWW.UNIRAC.COM - 246" RAIL - CUT-ONSITE RAIL #'- # #" - CUT-ONSITE RAIL LENGTH -REGULAR ATTACHMENT ADDITIONAL ATTACHMENT -RAFTER 301-24311 SPLICE BAR ROOF AREA 1 ARRAY 1 1" E/W MODULE GAP (TYP) 1491-6-11 N/Sl MODULE GAP (TYP) YP) RESUB Sep 07 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PLAN NORTH O N 0 W 00 z Q Cn >0� Jv0 Q m Q z z 0 Q LI L� o m ry LI m ENGINEER'S STAMP • � c _fI�1 z, �Q'•,'Q�G 1947�g0• SIQNAL�'�� " 07-SEP-2023 EXP.:15-DEC-2023 FOR PV RACKING ONLY Y U z z z z z , w Q o z wU) O w � w Z � U` O o > o� g Q L W H w= w 0 �uw Q � o w U S z Q o Lu o W ~ w O = o CMV N CMV N N O O O O O w C�V N C�V N N O O O O O w 0 O N c) xft MCKINSTRY PROJECT CITY OF EDMONDS PUBLIC SAFETY 250 5TH AVE N EDMONDS, WA 98020 TITLE ARRAY LAYOUT ROOF AREA 1 ARRAY 1 SHEET SM.301 KEY PLAN NOT TO SCALE NOT TO SCALE ROOF AREA 2 ARRAY 1 - 246" RAIL - CUT-ONSITE RAIL #'- # #" - CUT-ONSITE RAIL LENGTH 3C rJ T -REGULAR ATTACHMENT ADDITIONAL ATTACHMENT -RAFTER 1451-84311 1" E/W MODULE GAP (TYP) ill N/S M DULE GAP (TYP) PLICE BAR 6" EXPANSION GAP (TYP) RESUB Sep 07 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PLAN NORTH O N 0 W 00 z Q Cn > 0 Jv0 Q m Q z z 0 Q W o � m� m ENGINEER'S STAMP • � c _fI�1 01 N z, �Q'•,'Q�G 1947�g0• SIQNAL�'�� " 07-SEP-2023 EXP.:15-DEC-2023 FOR PV RACKING ONLY Y U z z z z z w CD Q F- O z w U) ww 0_ � w _ � � z O _ Z >- Q 0 U) Q w W = o JLLj o In Q Of o w wU) Z W U) W ~ w O = p 0 ? 2 U Q M M M M M O O O O O w C�V C�V C�V CV CV < 0 0 0 0 0 w w O N M "t x0ft MCKINSTRY PROJECT CITY OF EDMONDS PUBLIC SAFETY 250 5TH AVE N EDMONDS, WA 98020 TITLE ARRAY LAYOUT ROOF AREA 2 ARRAY 1 SHEET KEY PLAN NOT TO SCALE NOT TO SCALE SM.302 1/4"0 T-BOLT LOCATION 3/8"0 T-BOLT LOCATION \� 311 4 2911 216 SOLARMOUNT STANDARD RAIL SOLARMOUNT STANDARD RAIL PROPERTIES BEAM HEIGHT 2.570 in APPROXIMATE WEIGHT 0.728 plf CROSS SECTION AREA 0.625 in SECTION MODULUS (X-AXIS) 0.363 in SECTION MODULUS (Y-AXIS) 0.113 in MOMENT OF INERTIA (X-AXIS) 0.467 in MOMENT OF INERTIA (Y-AXIS) 0.045 in RADIUS OF GYRATION (X-AXIS) 0.865 in RADIUS OF GYRATION (Y-AXIS) 0.269 in SOLARMOUNT STANDARD RAIL s"0 T-BOLT AND SERRATED FLANGE NUT ERRATED FLANGE NUT ' HEX BOLT )OT ROOF ATTACHMENT BY OTHERS (�)- SOLARMOUNT STANDARD RAIL WITH L-FOOT AT STANDING SEAM ROOF 16 TOP VIEW —PRO SERIES ENDCLAMP SIDE VIEW —PRO SERIES ENDCLAMP (INSTALLED IN RAIL) 2. 30mm MODUL PRO SERIES MODULE MOUNTING HARDWARE 0 0 4" 1 1/2" 15/16" SPLICE DETAIL SIDE VIEW 711 1 16 Lr 1 2if TOP VIEW — PRO SERIES MIDCLAMP END VIEW — PRO SERIES MIDCLAMP SOLARMOUNT RAIL (LIGHT ISOMETRIC VIEW TYPICAL SPLICE BAR YPE F THREAD CREWS INCLUDED ISO VIEW — INSTALLED RESUB Sep 07 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O N 0 W 00 z Q ocl) >0 Jv0 m�Q Q z z owl Q�� o m� a m ENGINEER'S STAMP • � c _fI •� ova: f'!1't Z. �Q '•,'Q�G 1947��0, SIQNAL�'�� " 07-SEP-2023 EXP.:15-DEC-2023 FOR PV RACKING ONLY Y U z z z z z , 3: > > > `S W 0 z wc/) 0 0 �n W lc� z 0 H �_ cq w=_ w F- =Z075 ° 0 w ¢ W w F- O W w 5 o J c W 0 Q ~ z D W w 00 O 2 z 2 U 0 Q N N N N N O O O O O Lu N N N N N 00 M M Q O � N N N � r- � o 0 0 0 0 Lu MCKINSTRY PROJECT CITY OF EDMONDS PUBLIC SAFETY 250 5TH AVE N EDMONDS, WA 98020 TITLE SM DETAILS SHEET SM.400 POWER CLAMP - 1SS 024 124 I"IOJ&l.LJ - UI I .625 0.315 X 820 .099 � 118 ❑ SECTION A -A 3/8-24 U N F- 3 E 0.375 X 820 .30( .0.875 .750 FRONT VIEW RIGHT VIEW O N 0 W 00 z Q ocl) >0 Jv0 m�Q Q z z owl Q�� o C� mry w m ENGINEER'S STAMP • � c _fI�1 Z. Q'•,'Q�G �1947��0•`S SIQNAL�'� " 07-SEP-2023 EXP.:15-DEC-2023 FOR PV RACKING ONLY Y 3: W Z w o c/) _O C_n > W Z O H cq w F- = o -j = O w Z ¢ w D o w w w 75 � ::) o J c W 0 Q ~ z D W w Q O 2 z 2 U 0 Q N N N N N O O O O O Lu N N N N N 00 M M Q C, w O N C' lt i i 191:1 MCKINSTRY PROJECT CITY OF EDMONDS PUBLIC SAFETY 250 5TH AVE N EDMONDS, WA 98020 TITLE ATTACHMENT RESUB DETAILS Sep 07 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET SM.500