Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED BLD2024-1132+Manufacturer_Specifications_and_Installation_Instructions+8.28.2024_4.00.35_PM+4469150
FOR QUESTIONS, CALL THE PATENT NUMBERS Seattle Offlce EXHAUST HOODS ND-2/BD-2/SND-2 (CANADA) - CA PATENT 2520435 C. REGION 85 PHONE' (425) 212 - 5996 EMAIL, reg852econalr,coM unnn rArG'nn11emrf1Ar _ rnn.UR0000na MAX EXHAUST PLENUM HOOD CONFIG RISERS) HOOD TAG MODEL M NUFACTUR RLENGTH COOKING TYPE APPLIANCE DESIGN TOTAL HOOD END TO WIDTH LENG HEIGHT DIA CFM VEL SP NO TEMP DUTY CFM/FT EXH CFM CONSTRUCTION END ROW 1 5424 ECON-AIR 4' 0' 600 I HEAVY 275 1100 30' 30' 4' 1300 1584 -0.683' 431 SS ALONE ALONE EX-2 DEG WHERE EXPOSED unnn rhrr''f1DUATrnhr ! The following documentation shall be available on site for the building inspector: ! [Y!COE APPROVED ARCHITECTURAL PLAN SET ❑ COE APPROVED STRUCTURAL PLAN SET ❑ COE REVIEWED CALCULATION PACKET ❑ENERGY CREDIT WORKSHEET : ❑ SITE PLAN ! ❑ CIVIL PLAN c❑ :❑ FILTERS) LIGHTS) UTILITY CABINET(S) HOOD TAG EFFICIENCY E 7 WIRE FIRE SYSTEM I ELECTRICAL I SWITCHES FIRE SYSTEM HOOD HANGINC TYPE SIZE MODEL # QUANTITY NO TYPE QTY HEIGHT LENGTH MICRONS QTY TYPE GUARD LOCATION SIZE PIPING WEIGHT I CAPTRATE SOLD FILTER 2 20' 1 20' 85% SEE FILTER SPEC 2 L55 SERIES E26 NO NO 221 LBS HOO HOOD NO TAG OPTION 1 I JINSULATION FOR BACK OF HOOD, SPECIFICATION, CAPTRATE' GREASE-STOP`SOLO FILTER THE CAPTRATE GREASE -STOP SOLO FILTER IS A SINGLE -STAGE FILTER FEATURING A UNIQUE S-BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN, TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD 2-INCH DEEP HOOD CHANNEL(S). UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO COMPONENTS WHEN ASSEMBLED. GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICRONS IN SIZE AND LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE. THE CAPTRATE GREASE -STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05. MANUFACTURER APPROVED FOR USE IN SOLID FUEL APPLICATIONS AS A SPARK ARRESTER. EFFICIENCY VS. PARTICLE DIAMETER PRESSURE DROP VS. FLOW RATE N u m PARTICLE DIAMETER. CUM) CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH-, NFPA #96. NSF STANDARD #2, UL STANDARD #1046. INT. MECH. CODE (IMC). ULC-S649, eM -aoo ma FLOW RATE (CFM) NSF I�IIIVj)) O 1' LAYER OF INSULATION FACTORY HOOD CORNER INSTALLED IN INTERNAL BACK STANDOFF. HANGING ANGLE MEETS 0 INCH REQUIREMENTS FOR s m �ra rs"D <HARDWARE BY INSTALLER) CLEARANCE TO COMBUSTIBLE SURFACES, RAT v"oASHIM yr-um aua s amm-us sna x.L-TMswn yr-um aua s amm-us sna Ms Mrt. yr GI s wwcs�c NlfiE ommao STra RAT WASHIM aexa-r anxsaG FIELD CU`�'� 10' X 10' EXHAUST ve s RISER. Imm.w� yr-uTn Mj m HEX 54' U.L. LISTED L55 SERIE E26 CANOPY LIGHT FIXTURE — HIGH TEMP ASSEMBLY, 4' O'NOM,/4' 0,00'OD, PLAN VIEW - HOOD #1 4' 0.00" LONG 5424EX-2 HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2' - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4' OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. RECEIVED Aug 29 2024 BLD2024-1132 CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT FULL LENGTH � _ m 1i7 NANf.TNf. ANrI � �-\ (HARDWARE BY INSTALLER) yr - STUD_ im - GRME STEEL �FYy 3f4wor IJIMI&if1PL[] HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2' - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR FULL LENGTH HANGING ANGLES. MAINTAIN 1/4' OF EXPOSED THREADS BENEATH BOTTOM HEX NUT, TORQUE ALL HEX NUTS TO 57 FT-LBS. CLEARANCE TO COMBUSTIBLES HOODS # I SURFACE *CLEARANCE I TOP 18' FRONT 0' BACK 0' LEFT 18' RIGHT 18' - 00' CLEARANCE TO COMBUSTIBLES CONFORMS TO UL710 STANDARD. FIELD CUT EXHAUST RISER. HANGING ANGLE 20' CAPTRATE SOLE 1' LAYER OF INFgkTXiftiNIW INSTALLED IN 3' INTERNAL STANDOFF MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TE ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITF LOCAL CODE REQUIREMENTS GREASE DRAIN WITH REMOVABLE CUP 'ERIES E26 CANOPY LIGHT FIXTURE - TEMP ASSEMBLY, INCLUDES CLEAR THERMAL )HOCK RESISTANT GLOBE (L55 FIXTURE). -7 24' NOM. X. 80' SECTION VIEW - MODEL 5424EX-2 HOOD - #> BLD2024-1132 RECEIVED Aug 29 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT WVr.rArrOT T,AAr rArb+nallATrn Ar — rm)Aaa000AC FAN UNIT TAG QTY FAN UNIT MODEL # MANUFACTURER CFM ESP RPM MDTDR HP BHP PHASE VOLT FLA DISCHARGE T WVELOCITY SONES NO ENCL CEIGHEIGH 1 1 EADU85H ECON-AIR 1 1100 1 1.250 1 1279 TEAO-ECM 0.750 0.3770 1 1 115 1 8.9 1 348 FIRM 1 95 10.3 FAN UNIT TAG QTY NO DESCRIPTION 1 GREASE BOX 1 FAN BASE CERAMIC SEAL - DU/DR85HFA - INSTALLED AT PLANT - FOR GREASE DUCTS 1 1 HINGE KIT - SHIPS LOOSE FOR CURB SUPPLIED BY OTHERS 1 ECM WIRING PACKAGE - MANUAL OR 0-10VDC REFERENCE SPEED CONTROL -RTC- (TELCO MOTOR), CCW ROTATION 1 2 YEAR PARTS WARRANTY L,A ar Annz+c+an ars+c+ FAN EXHAUST SUPPLY UNIT TAG GREASE GRAVITY WALL SIDE GRAVITY MOTORIZED I WALL NO CUP DAMPER MOUNT I DISCHARGE DAMPER DAMPER I MOUNT I YES FEATURES, - DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS). 31 7/8' - ROOF MOUNTED FANS. - RESTAURANT MODEL - UL705 AND UL762 AND ULC-S645 - VARIABLE SPEED CONTROL. - INFERNAL WIRING. n - THERMAL OVERLOAD PROTECTION (SINGLE PHASE). III - HIGH HEAT OPERATION 300•F Q49'C). - GREASE CLASSIFICATION TESTING. - MENA 3R SAFETY DISCONNECT SWITCH. 30 1/2' 23' GREASE DRAIN. _L 2' I14 7/B' I L---J II 22 1/2' II DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS). 31 7/8' 7243/4' NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300•F (149•0 UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARF-L(P TEc_7 EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600•F (316•0 FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. OPTIONS - GREASE BOX. - FAN BASE CERAMIC SEAL - DU/DR85HFA - INSTALLED AT PLANT - FOR GREASE DUCTS. - HINGE KIT - SHIPS LOOSE FOR CURB SUPPLIED BY OTHERS. - ECM WIRING PACKAGE - MANUAL OR 0-10VDC REFERENCE SPEED CONTROL -RTC- (TELCO MOTOR), CCW ROTATION, - 2 YEAR PARTS WARRANTY. RECEIVED Aug 29 2024 BLD2024-1132 CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT ® GREASE DUCT & CHIMNEY SPECIFICATI❑NSI PR❑VIDE GREASE DUCT EQUAL TO EC❑N-AIR MODEL "EDW" ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK, MODEL "EDW" IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP L❑CKING C❑NNECTI❑NS SEALED WITH 3M FIRE BARRIER 2000 PLUS, MODEL "EDW" DOES NOT REQUIRE WELDING PR❑VIDING IT HAS BEEN INSTALLED PER THE MANUFACTURES INSTALLATI❑N GUIDE. PR❑VIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTI❑N AND EVERY 12, ON CENTER. PER MANUFACTURES LISTING MODEL "EDW" H❑RIZ❑NTAL RUNS LESS THAN 75 FT, CAN BE SLOPED 1/16" PER 12", H❑RIZ❑NTAL RUNS MORE THAN 75 FT. CAN BE SLOPED 3/16" PER 12", DUCT SHOULD BE SLOPED AS MUCH AS P❑SSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATI❑N IN H❑RIZ❑NTAL RUNS, IF THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF C❑MBUSTIBLE MATERIAL, PR❑VIDE UL-2221 OR UL-103 HT LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL CHIMNEY EQUAL TO EC❑N-AIR MODEL "EDW- 2R, 2R TYPE HT, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE 430 STAINLESS OUTER SHELL. CUSTOMER APPROVAL TO MANUFACTURE: APPROVED AS NOTED ❑ APPROVED WTRi NO EXCEPTION TAKEN ❑ REVISE AND RESUBMIT ❑ SIGNATURE YOUR TIRE DATE RECEIVED Aug 29 2024 BLD2024-1132 CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT GREAS, DO COVE GRE F 3 ( GREASE BOX INSTALLATION ri ncED POSITION FAN. HINGE KIT (OPTIC IRB. PARTS INCLUDED ins GREASE BOX. GREASE BOX COVER, GREASE PIPE. GREASE BOX FIELD INSTALLATION SHEET METAL SCREWS 3 - LONG 0/4' LG.). STEP 1 ATTACH GREASE BOX COVER TO THE CURB, HOLD 3' DIMENSION AS SHOWN ❑N PIC. 1. SCREW GREASE BOX COVER TO CURB USING (3) LONG (3/4' LG.) SCREWS AS SHOWN ON PIC. 2. CURB. PIC. 1 PIC. 2 CURB. GREASE BOX GREASE COVER. BOX STEP 2 COVER. ATTACH GREASE BOX TO GREASE BOX COVER, SLIDE AND DROP. AS SHOWN ON PIC. 3. CURB. POSITION GREASE BOX. PIC. 3 COVER. GREASE BOX. STEP 3 ---_V PIC. 4 INSTALL GREASE PIPE AS SHOWN ON PIC. 4. GREASE PIPE. BLD2024-1132 RECEIVED Aug 29 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Exhaust Fan Wiring JOB 6933306 - Meraki Tea Bar - U District DRAWING NUMBER EXH6933306-1 SHIP DATE 7/22/2024 MODEL EADU85H Installed Options RD 0-10 V XK-------------- GND MOTOR ❑PTIONAL 0-10VDC 24 VAC CONTROL SPEED REFERENCE P3 INPUT 1 SC-01 RD zav BK 2 TR-01 BK WH Component IdentlFication 3 K Label Description Location OH — — —o N=E4 wHMT-Ol �WH R 4 --J SW-01 *22 AWG WHITE ROTATION WIRE - MT-01 Fan Motor 131 o—GR z _ BMN MOTOR ONLY. CONNECT TO POWER wH wH LEG BLACK WIRE TO REVERSE ROTATION JUMPER WIRE DISCONNECTED. 5 TO REVERSE ROTATION SC-01 RTC-FSC-1 [11 CONNECT JUMPER FOR SW-01 Maln disconnect switch 131 CKEC MOTOR ONLY. 6 TR-01 24VAC 20VA Transformer[21 7 8 9 10 11 12 13 14 15 MOTOR INF❑ 16 EXHAUST 0.8HP-115V-1P-8.9FLA r 17 N) 0 N) 18 L CTR CAL NEO MAT ON MOTOR C RL MCAT 11.2A MOTOR/CTRL MOPi 20A W 19 IV 20 ;U m < D m NOTES DENOTES FIELD WIRING 21 m o DENOTES INTERNAL WIRING v �mO 1 m mm m WIRE COLOR 22 m (n o BK - BLACK YW - YELLOW BL - BLUE GR - GREEN o p T BR - BROWN GY - GRAY 23 1 ' 1 E LE RD - RED PK - PPR INK WH - WHITE FI.TiICTRrrAL PArRlAGA! - .InR RA3.R.RAR NO TAG PACKAGE M LOCATION SWITCHES OPTION I FANS CONTROLLED LOCATION QUANTITY TYPE I 4 I HP JVOLTJ FLA 1 SC-111110MA WALL MOUNT IN SS BOX SS WALL MOUNT BOX 1 LIGHT 1 FAN SMART CONTROLS THERMOSTATIC CONTROL I W/ RELAY ON/OFF WITH SUPPLY EXHAUST 1 0.750 115 8.9 SUPPLY 1 1 10.2501 115 1 3.6 RECEIVED Aug 29 2024 BLD2024-1132 CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT JOB NO MODEL NUMBER IRA"BY �^� T� IJLSL;K1N 11LJN OF UVLKA I IUN, 6933306 SC-111110MA INSTALL 12DV 1 Phase s/ R trol for 1 Exhaust Fan, 1 Supply Fon, Exhaust an In Floe, LWft wt inFlm, Relay On/Off .kh JOB NAMF DA- DWG NO SUPP1y Fan, FWW On/Off Thernastotk=ky r—t Wlsd Roan texperature sensor shpped loose for fl.Ld kutWatlon. Merakl Tea Bar - U District 7/22/2024 ECP #1-1 1 2 3 1 4 5 8 7 8 9 10 11 12 13 14 15 18 17 18 19 20 21 22 23 24 BREAKER PANEL TO PRIMARY CONTROL PANEL Responsibility, Electrician BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED REAKER PANEL PRIMARY CONTROL -------- ------Hat - H1 BREAKER 1PH Neutral - N1 120 V -Grau^d 15 A CONTROL POWER. DO NOT WIRE TO GFCI OR SHUNT TRIP BREAKER. 1ST HOOD LIGHT BREAKER SHARED W/ CONTROL POWER. SWITCH #1 -------------- Hat — L1 BREAKER 1PH - - - - - - - - - - - - - - NeutmL -� 115 V MCA, ILI A MOCP, 20 A ---------------Ground_-� EXH-1 - ---------__Hot -E BREAKER 1PH _ _ _ _ _ _ _ _ _ _ Neutral _ 115 V---------------Ground -� MCAT SUP-2 CONTROL PANEL TO ACCESSORY ITEMS Responsibility, Electrician MICROSWITCH 1 :ONTROL PANEL TO 41N0 oFF C, NC FIRE SYSTEM ARl -------------- ----J MICROSWITCH WIRE CI TO COMMON (1). WIRE ARI TO NORMALLY CLOSED (2). CI TO ARI SHOULD HAVE MS-1 4,NOBFF CONTINUITY WHEN ARMED. 1,1 ,NC C1 IF MORE THAN ONE FIRE SYSTEM, WIRE r - - -2 - - J 4,N06F& IN SERIES AS SHOWN L 1,�,,NC AD1 - - - - - - - - NTROL PANEL J4 ALL SWITCHES FACTORY WIRED TO CAT-5 CONNECTION SWITCHES HOOD LIGHTS 1 CONTROL PANEL - - - - - - - - - - - BLACK 7I TO ----------- WHITE = HOOD LIGHTS - GREEN - - - - _J 1400 W MAX WIRE TO J-BOX ON TOP OF HOOD CONTROL PANEL TO FANS CONTROL PANEL - - - - - - - - - - - - - - - - {�-� Responsibility, Electrician TO WIRE TO CONTROL BOARD, INSTALL ROOM TEMP _ PRIMARY PANEL FANS ROOM TEMP SENSOR IN ROOM AWAY FROM HEAT SENSOR SOURCES. DO NOT INSTALL SENSOR GROUPS, Load Wlring - VI-1 i HOT FANS 0 1 - - - - - - 1FLa8.9 EXH-1 ON THE CEILING GRID, SEE MANUAL. C-1 MEG 2 / NEUTRAL- - - - - - - - - - - --0 HP 0.750 WIRE DIRECT ---ozROONn--------- y4p115V - -�I, CONTROL PANEL -------------- -- TO T2B 1 TO STARTER WIRE TO DUCT SENSOR WIRE T� Cl)NTR�L BOARD, SENSOR MOUNTED IN EXHAUST DUCT HOOD RISER I DISCONNECT FAN, 02 LEG 1 / NOT---- BLACK SUP-2 THE NG IFOLLIIWIMAY Load Wlring TI - o HP 02M MAY OR NOTBE C_2 T2 LEG 2/ NEUTRAL---- A WHITE o VOLm15 V REQUIRED BASED ON JOBSITE - - - GROUND- - - -A GREEN I, SPECIFICATIONS dIRE DIRECT WIRE TO FACTORY SHUNT COIL ro STARTER PROVIDED CONDUIT DROP CONTROL PANEL - - - - - HOT TO SHUNT COIL _ yL SIGNAL FOR L NI - - NEUTRAL FROM SHUNT EXTERNAL ST TERMINAL IS ENERGIZED SHUNT TRIP IN FIRE CONDITION. ONTAR_COIL CONTROL PANEL ---HOT TO CONTACTOR COIL 7 SIGNAL FOR - NEUTRAL TD CONTACTOR CD_IL - - - - - EXTERNAL KS TERMINAL IS DE -ENERGIZED CONTACTOR COIL IN FIRE CONDITION. KUL —ILL ar l,1 NORMALLY OPEN DRY CONTACT -------------- -- ON/OFF WITH SFC2 COMMON _ SUPPLY FAN _ _ _ _ _ _ _ _NORMALLY OPEN GROUP 1 SPARE CONTACTS WILL MAKE COMMON TO NORMALLY OPEN WHEN SUPPLY FAN IS ON. DIMS SWITCH CONTROL PANEL - - - - - - - - - - - - - - --0'-C�117 TOMacy -------------- ----J EXTERNAL SIGNAL SWITCH THROUGH HMS WILL ACTIVATE ZONEI FANS AND SWITCH LIGHTS BLD2024-1132 RECEIVED Aug 29 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A I B I C D I E F G I H I I UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. MOTOR POWER CIRCUIT c� ey 1 J9 120V HK _ CONTROL INPUT 120V Hl=LINE, N1=NEUTRAL, ' z a 14 AWG C-1 BK LI ' W� 2 Lm MTR: EXH-1 CONTi100-K12D10 FNLA 8.9 GAS HK __ 15A BREAKER. D❑ NOT \ � CONNECT TO SHUNT TRIP 24V 0J%ae 4 115PV 20 A 13 Y r 0 ® BREAKER. SEE i 1 0OO ®OO © 7 � BK - + J6 2 -- BK INSTALLATION SCHEMATIC 24V 14 AWG C-2 T1 MTR:SUP-2 coNr:lo0-KDSD10 _ _ FOR ADDITIONAL REQ. PS-01 TER TERMINAL GAS USED FOR a 1 PH C ^-!"B2CP us V �'s�'W��; 2 FLA:3.6 POWERED GAS HP:0.2s0 Hl HK -- IJAC U 15 A VALVES ONLY E] a PANEL LIDIi z� 3 4 J7 120V l BK HK 14AWG R 1 I�aHI BK WH Jr (3, BK HOOD GHTSJaN1 C-1 BK C-2 N1 6 N1 DC+ Ham® RD-1 7 PR RO1 AR1 H�L RA-�N1 SF1 BK RA-2 7 DRY CONTACTS (SHOWN DE -ENERGIZED) 14 AWG RA-1-1 ON/OFF MAKE UP AIR INTERLOCK. - — WITH JUMPR C YW FIRE 14 AWG RA-2-1 8 N OFF NO WITH C YW SUP E PM03 ECP1M03 14 AWG RA-2-2 RE C YW 9 Aug BLD2024-1132 CITY DEVELOP DEF LID 14x18x6Box/ FACTORY WIRING SCHEMATIC CIRCUIT BOARDS RA-x RD—x 120 VAC 24 VDC RELAY RELAY NO 4 3 NO 4 3 NC 2 1 NC 2 1 COIL 8 7 COIL 8 7 COM 6 5 COM 6 5 ST-X Storter e OL-X Overload C-X Contactor e PS-1 Power Sup24VD:: MDP18-24A-IC RA-x 120V Relayy DPDT 34.110.01840 RD-x 24VDC Ligqht Relay 34.110.0108,0