APPROVED PLN RESUB1 BLD2024-1132+Mechanical_Plan+9.12.2024_5.02.23_PM+4497817. TYPICAL UNISTRUT HOOD SUPPORT DETAILS 12 GA. "U" CHANNEL BAR SUPPORT \ A �Nt ERT Ek 1.2 NOTES: 3" No. 10 METAL FASTENERS BETWEEN WALL STUD & SUPPORT BRACKET (ON CENTER OFF FRAMING STUDS) (C) 16 GA. GALVANIZE SUPPORT BRACKET (A) 2.5" METAL FASTENERS BETWEEN S/S WALL & WALL FRAME NON-COMBUSTIBLE WALL FRAME /(B) 1.5" METAL FASTENERS BETWEEN HOOD & SUPPORT BRACKE 3" STAND OFF S/S FLASHING PROPERTY LINE �a 18 GA. STAINLESS STEEL TYPE 1 GREASE HOOD 3M #615+ FIRE BARRIER DUCT WRAP: 1. THE EXHAUST FAN & MAKE UP AIR SYSTEM WILL BE CONNECTED BY AN ELECTRICAL INTERLOCKING SWITCH 1 OR 2 HOUR SHAFT ALTERNATIVE & ZERO FOR SAME TIME OPERATION. CLEARANCE TO COMBUSTIBLE CONSTRUCTION 1 2 LAYER FIREMASTER DUCT WRAP 2 FILAMENT TAPE 3 BANDING 4 3" PERIMETER OVERLAP 5 3" LONGITUDINAL OVERLAP 6 1/2" DIAMETER HANGER ROD 7 1 1/2" x 1 1/2" x 1/8" ANGLE ADJACENT BUILDING UNDER DIFFERENT PARCEL MAIN ST SCALE: Y " = 1' 2. ALL EQUIPMENT SHOWN ON THIS DRAWING SHALL BE AS SPECIFIED OR EQUAL. 3. THE PROPOSED WALL TO BE CONSTRUCTED TO MEET THE FIRE CODES FOR TYPE 1 HOOD (1 HR. FIRE RESISTIVE SHIELD). 4. STAINLESS STEEL SHEET SHALL COVER THE ENTIRE COOKING AREA. 5. ALL HOOD, DUCT JOINS, & SEAMS SHALL BE EXTERNAL GREASE TIGHT WELD. 6. EXHAUST FAN SHALL BE 40" (MIN.) DISCHARGE ABOVE ROOF. 7. MIN. DISTANCE BETWEEN EXHAUST FAN & MAKE UP AIR SHALL BE NO LESS THAN 10'. 8. FIRE SUPPRESSION SYSTEM WILL BE UNDER SEPERATE PERMIT. SCOPE OF WORK: INSTALL ONE 4' COMMERICAL KITCHEN (TYPE 1) GREASE HOOD, ONE EXHAUST FAN, ONE MOTORIZED MAKE UP AIR DAMPER, & GREASE DUCT WITH FIRE BARRIER WRAP. PROJECT INFORMATION: TENANT: Claire's Pantry 301 Main St Edmonds, WA 98020 PROPERTY OWNER: JC PROPERTY INVESTMENTS LLC PARCEL TAX ACCOUNT: 00434400601202 LEGAL DESDRIPTION: EXHAUST HINDGE KIT INSTALLATION HINDGE BRACKET ROOF LINE THREADED CABLE _ ROOF CURB - GREASE DUCT ------------ Zone ' BD1- Corner Flag Setbacks: Required Actual Front Sides Rear Other ----- 30' 16-8 Height =_ ----- 314" For proposed exhaust fan only VINCI SCALE: uf Edmonas MAP I Ing Department ---- Work ; Address' ------------------------------------- Owner -------------------------- TYPE 1 HOOD 301 MAIN ST ------------------------------ CLAIRES PANTRY Approved Date 09/ 1 2024 Building Official! r(, Permit Number BLD2024-1132 Approved DFM Ck6s Burt South County Fire Date: 09/23/2024 09-11-2024 RESUB 1 PLAN REVIEW NOTES: APPROVED DFM BURT SEE 1.2 FIREWRAP — ALL AROUND CONTINUOUS TIGHT WELDED 16 GA. GALVANIZE DUCT ALL AROUND CONTINUOUS LIQUID TIGHT WELD BETWEEN DUCT AND HOOD SYSTEM 3 STAINLESS STEEL (20 GA.) FLASH NON-COMBUSTIBLE WALL FRAME - %" TYPE "X" FIRE RATED - SHEET ROCK STAINLESS STEEL WALL w/ ROXUL AFB 1 HR FIRE PAD 3" AIR SPACE FLOOR 3/8" THREADED STEEL ROD (FRONT SUPPORT) 18 GA. STAINLESS VPAOR PROOF �' STEEL TYPE I GLASS GLOBE GREASE HOOD STAINLESS STEEL GREASE FILTER GREASE T-9" GUTTER COOKING EQUIPMENT 0 SECTION ELEVATION VIEW SCALE: NTS FAN EQUIPMENT SCHEDULE BRAND CFM HORSE ELECTRICAL UNIT NAME MODEL # REQUIRED POWER S P. (VOLTAGE)/(PHASE) d.B.A. EXHAUST FAN ECON-AIR EADU85H 1100 3/4 1.25" (115-230V)/(1 PH) 64 d.B.A. MOTORIZED ECON-AIR A1-U-MBDD DAMPER EXHAUST FAN MIN.40" 12 GA. "U" CHANNEL BAR SUPPORT FIREWRAP SEE 1.2 10" x 10" ALL AROUND CONTINUOUS TIGHT WELDED GREASE DUCT (16 GA. GALVANIZE STEEL) STAINLESS STEEL WALL w/ ROXUL AFB 1" FIRE PAD EQUIPMENT 1. TYPE 1 HOOD SYSTEM <4'(W) x 4'(L)> 2. 6 BUNER RANGE w/ OVEN <36"(W) x 50"(H)> APPROVED BY PLANNING CPA&A/V-SC Sep 13 2024 O rn—nTnTn=nTnTn=n7 FRONT VIEW SCALE: %2 = 1' %"THREADED STEEL ROD 20 GA. FLASHING 16'-83�4" MOTORIZED MAKE UP AIR DAMPER ■ O O� LL ca � V�LO 0 CD U CL co VU) z Q .Q l.2 V1 CD_ W W 00 Cn E FM 3 .� = ,v J Cn W Cl) Uj� L N d LL F*;c H U Q RESUB Z Sep 13 2024 OCITY OF EDMONDS U DEVELOPMENT SERVICES DEPARTMENT ALL ORK SUBJECT TO FIELD IN PECTION FOR CO E COMPLIANCE APPROVED �.,gINS MUST B JO*SITF: �+ o N O 4-0 00 CO 0 o �-0 w o _ Wv Cn 0 a 0 a U W O a SHEET NUMBER FOR QUESTIONS, CALL THE PATENT NUMBERS Seattle Offlce EXHAUST HOODS ND-2/BD-2/SND-2 (CANADA) - CA PATENT 2520435 C. REGION 85 PHONE' (425) 212 - 5996 EMAIL, reg852econalr.coM HOOD INFORIllATION — .IOR4704i.R.R2 MAX EXHAUST PLENUM HOOD CONFIG RISERS) HOOD TAG MODEL MANUFACTURER LENGTH COOKING TYPE APPLIANCE DESIGN TOTAL HOOD END TO WIDTH I LENG HEIGHT DIA I CFM I VEL I SP NO TEMP DUTY CFM/FT EXH CFM CONSTRUCTION END ROW 1 5424 ECON-AIR 4' 0' 600 I HEAVY 275 1100 10' 10' 4' 1100 1584 -0.683' 430 SS ALONE ALONE EX-2 DEG WHERE EXPOSED FILTERS) I LIGHTS) UTILITY CABINET(S) I HOOD TAG EFFICIENCY E 7 WIRE FIRE SYSTEM ELECTRICAL SWITCHES FIRE SYSTEM HOOD HANGINC TYPE SIZE MODEL # QUANTITY NO TYPE QTY HEIGHT LENGTH MICRONS QTY TYPE GUARD LOCATION SIZE PIPING WEIGHT I CAPTRATE SOLD FILTER 2 20' 20' 85% SEE FILTER 2 L55 SERIES E26 NO NO 221 SPEC LBS Hoo HOOD NO TAG OPTION 1 1 JINSULATION FOR BACK OF HOOD. .... _..___... __.... .. . .. _... _.�. ------ ----0 ..... .. __. __.. THE CAPTRATE GREASE -STOP SOLO FILTER IS A SINGLE -STAGE FILTER FEATURING A UNIQUE S-BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN, TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD 2-INCH DEEP HOOD CHANNEL(S). UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO COMPONENTS WHEN ASSEMBLED. GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICRONS IN SIZE AND LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE. THE CAPTRATE GREASE -STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05. MANUFACTURER APPROVED FDR USE IN SDLID FUEL APPLICATIONS AS A SPARK ARRESTER. EFFICIENCY VS. PARTICLE DIAMETER PRESSURE DROP VS. FLOW RATE u m PARTICLE DIAMETER. CUM) CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH-. NFPA #96. NSF STANDARD #2. UL STANDARD #1046. INT. MECH. CODE (IMC). ULC-S649. ea raoo aro FLOW RATE (CFM) 1' LAYER OF INSULATION FACTORY INSTALLED IN INTERNAL BACK STANDOFF MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES, FIELD CL 10' X 10' EXHAUST RISER. 54' U.L. LISTED L55 SERIE E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, 4' O'NOM./4' 0.00'OD. PLAN VIEW - HOOD j1 4' 0.00" LONG 5424EX-2 HOOD CORNER HANGING ANGLE aua s ammaso (HARDWARE BY INSTALLER) seen r« rags Llr FLAT WASHM yr - 18 TP1 mAa s I area rac fart. RAT WASIEA ve• auoE sFLAT WASHM atm e owgmmY STEEL HEX N= HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2' - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN, MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4' OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. FULL LENGTH � _ Y m NANf.TNf. ANrI � �-\ (HARDWARE BY INSTALLER) yr - srea yr - GGGE STEEL HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2' - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR FULL LENGTH HANGING ANGLES. MAINTAIN 1/4' OF EXPOSED THREADS BENEATH BOTTOM HEX NUT, TORQUE ALL HEX NUTS TO 57 FT-LBS, CLEARANCE TO COMBUSTIBLES HOODS # I SURFACE *CLEARANCE I TOP 18' FRONT 0' BACK 0' LEFT 18' RIGHT 18' - 110' CLEARANCE TO COMBUSTIBLES CONFORMS TO UL710 STANDARD. FIELD CUT EXHAUST RISER. HANGING ANGLE 20' CAPTRATE SOLC 1' LAYER OF INF§kTXiftiNIW INSTALLED IN 3' INTERNAL STANDOFF MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TC ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITF LOCAL CODE REQUIREMENTS GREASE DRAIN WITH REMOVABLE CUP 'ERIES E26 CANOPY LIGHT FIXTURE - TEMP ASSEMBLY, INCLUDES CLEAR THERMAL )HOCK RESISTANT GLOBE (L55 FIXTURE). -7 24' NOM. X. 80' SECTION VIEW - MODEL 5424EX-2 HOOD - #9 W VLrAifOT WA.hl iAFWADIlAgmAf — FAI)AIYA44009 FAN UNIT TAG QTY FAN UNIT MODEL # MANUFACTURER CFM ESP RPM MOTOR HP BHP PHASE VOLT FLA DISCHARGE WEIGHT SONES NO ENCL VELOCITY CEIGH 1 1 EADU85H ECON-AIR 1 1100 1 1.250 1 1279 TEAO-ECM 0.750 0.3770 1 1 115 1 8.9 1 348 FPM 1 95 10.1 FAN UNIT TAG QTY NO DESCRIPTION 1 GREASE BOX 1 FAN BASE CERAMIC SEAL - DU/DR85HFA - INSTALLED AT PLANT - FOR GREASE DUCTS 1 HINGE KIT - SHIPS LOOSE FOR CURB SUPPLIED BY OTHERS 1 ECM WIRING PACKAGE - MANUAL OR 0-10VDC REFERENCE SPEED CONTROL -RTC- (TELCO MOTOR), CCW ROTATION FAN EXHAUST SUPPLY UNIT TAG GREASE GRAVITY WALL SIDE GRAVITY MOTORIZED I WALL NO CUP DAMPER MOUNT I DISCHARGE DAMPER DAMPER I MOUNT 1 YES FAN #1 EADU85H - EXHAUST FAN FEATURES, - DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS). 31 7/8' - ROOF MOUNTED FANS. - RESTAURANT MODEL - UL705 AND UL762 AND ULC-S645 - VARIABLE SPEED CONTROL. - INTERNAL WIRING. n - THERMAL OVERLOAD (SINGLE PHASE). rl - HIGH HEAT OPERATIONN 3DO300* (14F Q49'C). - GREASE CLASSIFICATION TESTING. - MEMA 3R SAFETY DISCONNECT SWITCH. 30 1/2' 23' GREASE DRAIN. 2' L�114 7/8'22 1/2' II DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS). 31 7/8' 7243/4' NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300•F (149•0 UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARF-LP TEc_7 EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600•F (316•0 FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. OPTIONS - GREASE BOX. - FAN BASE CERAMIC SEAL - DU/DR85HFA - INSTALLED AT PLANT - FOR GREASE DUCTS. - HINGE KIT - SHIPS LOOSE FOR CURB SUPPLIED BY OTHERS. - ECM WIRING PACKAGE - MANUAL OR 0-10VDC REFERENCE SPEED CONTROL -RTC- (TELCO MOTOR), CCW ROTATION. - 2 YEAR PARTS WARRANTY. ® GREASE DUCT & CHIMNEY SPECIFICATI❑NS1 PR❑VIDE GREASE DUCT EQUAL TO EC❑N-AIR MODEL "EDW" ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK, MODEL "EDW" IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP L❑CKING C❑NNECTI❑NS SEALED WITH 3M FIRE BARRIER 2000 PLUS, MODEL "EDW" DOES NOT REQUIRE WELDING PR❑VIDING IT HAS BEEN INSTALLED PER THE MANUFACTURES INSTALLATI❑N GUIDE. PR❑VIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTI❑N AND EVERY 12' ON CENTER. PER MANUFACTURES LISTING MODEL "EDW" H❑RIZ❑NTAL RUNS LESS THAN 75 FT, CAN BE SLOPED 1/16" PER 12", H❑RIZ❑NTAL RUNS MORE THAN 75 FT. CAN BE SLOPED 3/16" PER 12", DUCT SHOULD BE SLOPED AS MUCH AS P❑SSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATI❑N IN H❑RIZ❑NTAL RUNS. IF THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF C❑MBUSTIBLE MATERIAL, PR❑VIDE UL-2221 OR UL-103 HT LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL CHIMNEY EQUAL TO EC❑N-AIR MODEL "EDW- 2R, 2R TYPE HT, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE 430 STAINLESS OUTER SHELL. CUSTOMER APPROVAL TO MANUFACTURE: APPROVED AS NOTED ❑ APPROVED WTTN NO EXCEPTION TAKEN ❑ REVISE AND RESUBMIT ❑ SIGNATURE YOUR TIRE DATE GREAS, DO COVE GRE F any. 3 ( GREASE BOX INSTALLATION ri ncED POSITION FAN. HINGE KIT (OPTIC IRB. POSITION PEVA2 OB/19/02 PARTS INCLUDED GREASE BOX. GREASE BOX COVER, GREASE PIPE. GREASE BOX FIELD INSTALLATION SHEET METAL SCREWS 3 - LONG 0/4' LG.). STEP 1 ATTACH GREASE BOX COVER TO THE CURB, HOLD 3' DIMENSION AS SHOWN ❑N PIC. 1. SCREW GREASE BOX COVER TO CURB USING (3) LONG (3/4' LG.) SCREWS AS SHOWN ON PIC. 2. / --- - CURB. PIC. 1 PIC. 2 T3' I CURB. GREASE BOX GREASE COVER. BOX STEP 2 COVER. ATTACH GREASE BOX TO GREASE BOX COVER, SLIDE AND DROP. AS SHOWN ON PIC. 3. , CURB. PIC. 3 GREASE BOX. GREASE BOX COVER. STEP 3 ---_V PIC. 4 INSTALL GREASE PIPE AS SHOWN ON PIC. 4. GREASE PIPE. Exhaust Fan Wiring JOB 7041332 - Claire Pantry - Edmonds DRAWING NUMBER EXH7041332-1 SHIP DATE 9/12/2024 MODEL EADU85H Installed Options RD 0-10 V XK-------------- GND MOTOR ❑PTIONAL 0-10VDC 24 VAC CONTROL SPEED REFERENCE P3 INPUT 1 SC-01 RD zav BK 2 TR-01 BK WH Component Identlfication 3 K _ _ Label Description Location i WH MT-Ol �WH oo L—_J R 4 SW-Ol *22 AWG WHITE ROTATION WIRE - MT-01 Fan Motor 131 o—GR _ BMN MOTOR ONLY. CONNECT TO POWER WH wH LEG BLACK WIRE TO REVERSE ROTATION JUMPER WIRE DISCONNECTED. 5 TO REVERSE ROTATION SC-01 RTC-FSC-1 [11 CONNECT JUMPER FOR SW-01 Maln dlsconnect swltch 131 CKEC MOTOR ONLY. 6 TR-01 24VAC 20VA Transformer[21 7 8 9 10 11 12 13 14 15 MOTOR INF❑ 16 EXHAUST 0.8HP-115V-1P-8.9FLA 17 18 L CTR CAL NEO MAT ON MOTOR C RL MCAT 11.2A MOTOR/CTRL MOPi 20A 19 20 NOTES DENOTES FIELD WIRING 21 DENOTES INTERNAL WIRING WIRE COLOR 22 BK - BLACK YW - YELLOW BL - BLUE GR - GREEN BR - BROWN GY - GRAY 23 OR - OR' -,E PR - PURPLE RD - RED PK - PINK WH - WHITE ELECTRICAL PACKAGE - 2 NO TAG PACKAGE # LOCATION T.-n .t Bk.d Por .Iced cornecdan COvrctlon Por Mod F-ft" o W FMd VFed FINd Connecllon Mt.rvno Fl d Corr—ib to Roubr Vlrea Ot Poch. pt EiMr`rrt o.kch O O IPq�Q��'p]o O �� � GIIWw Motlule tr nodulr pa CASlink Monitor and Control Hood control poomd to support oommwdaaUnns to cloud —based Building Yana M-Ca System — Control PmwL to allow+ &(loud based Building Management System to for outd(lou as MONITOR N. the Ust mon#or read fir-t-1 --I t a W- d — Hood Control PmwL to allow+ &(loudbased Building Management System to oonhv9 parameters outiMwd as CONTROL in the points gist. Hood Control Pane! to allow aloud —based Building Yanagematt System to implement SYSTRM ECONOMISER control strategies Jor ILUy integrated BuiMV Yamgement. MONITORING AND CONTROL POINTS LIST DLv Paaww.. F..K- sc PaawFw. Fu wK- Roam Tmlp.rahoo MOLTTOR Ream 1Yrnp.n0or.61 MOLTTOR Duct T.eB.nMo.(1 MOLTTOR Duo/ T*"wa0v.() MOM= LMd Dwo%arp Tmlp.nnae MOLTTOR Mgt Dluhsrp Tmyrsahw. MONnw DMeha. my DL.dA AnW.rohoa maw= llimh.11 RN Diwh-w T--w ..hoc momw Too. ap-d MOLTTOR co hvum loom MOMTOR Too, A"V-W MOM= Jbn Faun. MOM= Poo. Pawn MOM= Jbn gtatue MOMTOR "D Foam MOLTTOR POD Faun. MOMTOR Cadwgw Fauw MOLTTOR POD F4u r aw P. -kw.. MOMTOR Pm Faun, MOMTOR Mr. Condom- J10JUM Pm staFu MOM= ca" Are sa min MOATTOR PCD Fadm J10ha R awwkw p.ay.. MOMTOR PM xun tree Fao•nmew MOLTTOR r— Dram .) MOMTOR t CONTROL A. Caoatun MOM= Lyht. BUNmt.) MOMTOR t CONTROL Cau Ftw Dy mm Mom= ►a h Bota. Mom= t CONTROL Botow Pnwwe. YOA7TtOR Prey rho. Burton lwL7TOR t CONTROL Fan. Dram MOATM ! COAr t Ltghm Duna. MOMTOD ! COAr t ►" DWmn Mom= t CONTROL JODCLalre Pantry - Edmonds LOCATION Edmonds, WA, 98020 DOW 9/12/2024 2 oT�r¢®# p r, econsair Lt LOBPA4 JDC-8 DIPC 7 DR41PN 9YJDC-85 REM. SCALE 3/8' = V-0' SWITCHES OPTION FANS CONTROLLED LOCATION QUANTITY TYPE m HP VOLT FLA 1 SC-111110MA WALL MOUNT IN SS BOX SS WALL MOUNT BOX 1 LIGHT 1 FAN SMART CONTROLS THERMOSTATIC CONTROL W/ RELAY ON/OFF WITH SUPPLY EXHAUST 1 0.750 115 6,9 SUPPLY 1 0.250 115 3,6 1 2 3 1 4 5 8 r8 7 9 10 11 12 13 14 15 18 17 18 19 20 21 22 23 24 7041332 :L NUMBER SC-111110MA NAMF Clalre Pantry - Edmonds BREAKER PANEL TO PRIMARY CONTROL PANEL Responsibility, Electrician BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED REAKER PANEL PRIMARY CONTROL ------ ---------Hat — H1 BREAKER 1PH Neutral - N1 120 v —Ground 15 A CONTROL POWER. DO NOT WIRE TO GFCI OR SHUNT TRIP BREAKER. 1ST HOOD LIGHT BREAKER SHARED W/ CONTROL POWER. SWITCH #1 -------------- Hat — L1 BREAKER 1PH -------------- Neutral -� 115 V MCA, 11.1 A MOCP, 20 A ---------------Grountl_ EXH-1 -� ----------__Hot -� Ground BREAKER 1PH _ _ _ _ _ _ _ _ _ _ Neutral _ 115 V--------------- -� MCAT SUP-2 DPI DWG NO 9/12/2024 ECP CONTROL PANEL TO ACCESSORY ITEMS Responsibility, Electrician MICROSWITCH 1 :ONTROL PANEL TO 41NO CAP OFF C, NC FIRE SYSTEM AR1 —I —T—C—M—O— —D.----- --- -J MICROSWITCH WIR—E WIRE ARI TO NORMALLY CLOSED (2). CI TO ARI SHOULD HAVE MS-1 4,NOER& CONTINUITY WHEN ARMED. li�iNC C1 IF MORE THAN ONE FIRE SYSTEM, WIRE r - - -2 - - J 4,NO6R& IN SERIES AS SHOWN L 1,�,NC AD1(7- - - - - - - - - - - - - - - - - - J NTROL PANEL J4 ALL SWITCHES FACTORY WIRED TO CAT-5 CONNECTION SWITCHES HOOD LIGHTS 1 CONTROL PANEL - - - - - - - - - - - BLACK 7I TO ----------- WHITE = HOOD LIGHTS - GREEN - - - - _J 1400 W MAX WIRE TO J-BOX ON TOP OF HOOD CONTROL PANEL TO FANS Responsibility, Electrician COMM CAT-5 ETHERNET CONNECTION ROUTER CONTL ROL PANE _ PRIMARY PANEL FANS TO - ___________ _ - FANS 01 EXH-1 WORLD WIDE WIRE DIRECTLY TO COMMUNICATION MODULE. NET REQUIRES 1) DHCP 2) Land Wlring - LEG 1 / HOT FLa8.9 WEB UDP PORT 1444 & 1445 OPEN FOR C-1 LEG 2 / NEUTRAL- - - - - - - - - - - --o HP 0.750 YULT-115 V OUTBOUND TRAFFIC ONLY. WIRE DIRECT---1xPUNn--------- --�I, TO STARTER WIRE TO CONTROL PANEL T1Q DISCONNECT - - - - - - - - - - - - - - - -� FAN, 02 TO T1B WIRE TO CONTROL BOARD, INSTALL ROOM TEMP SUP-2 FLN3.6 ROOM TEMP SENSOR IN ROOM AWAY FROM HEAT Land Wlring T1 - AEG 1 i NOT---- BLACK o HP 02M SENSOR SOURCES. DO NOT INSTALL SENSOR GROUPS C-2 T2 LEG 2iNEUTR-^L---- WHITEo VRn115 V ON THE CEILING GRID, SEE MANUAL. - - -GROUND- - - -A GREEN I, CONTROL PANEL dIRE DIRECT WIRE TO FACTORY - - - - - - - - - - - - - - - - - ro STARTER PROVIDED CONDUIT DROP TO WIRE TO CONTROL BOARD. HOOD 1 DUCT SENSOR SENSOR MOUNTED IN EXHAUST DUCT RISER I THE FOLLOWING CONNECTIONS MAY OR MAY NOT BE REQUIRED BASED ON JOBSITE SPECIFICATIONS SHUN COIL - - - - - HOT TO SHUNT CUIL � CONTROL PANEL SIGNAL FOR - - NEUTRAL FROM SHUNT COIL - - - - - EXTERNAL ST TERMINAL IS ENERGIZED SHUNT TRIP IN FIRE CONDITION. ONTTAACTTPR-COIL CONTROL PANEL _ _ _ HOT TO CONTACTOR COIL v`--- SIGNAL FOR NEUTRAL TD CONTACTOR COIL - - - - - EXTERNAL KS TERMINAL IS DE -ENERGIZED CONTACTOR COIL IN FIRE CONDITION, 1 Phnss s/ contrd Aar 1 Exhaust Fan, 1 SuPP1Y Fan, Exhaust on In FM, U*ts art In FNv, RelnY On/Off skh I V Fan, FWW On/Off Tharnastotk.My r ntr aUad Roar tsxpsratw ssnsar shkn d loose for field F�staBatJen. CONTROL PANEL - - - - - - - - - - - COMMON _ _ DRY CONTACT - - - - - - - NORMALLY OPEN - _ ON/OFF WITH - - - - - - - - - - - COMMON _ _ SUPPLY FAN _ _ _ _ _ _ _ _NORMALLY OPEN GROUP I SPARE CONTACTS WILL MAKE COMMON TO NORMALLY OPEN WHEN SUPPLY FAN IS ON. BMS SWITCH CONTROL PANEL H1— — — — — — — — - - - - - - -j�D-CNO TO I01 ---- J — - - - - - - - - - - - - - EXTERNAL SIGNAL SWITCH THROUGH BMS WILL ACTIVATE ZONEI FANS AND SWITCH LIGHTS A I B I C D I E F GI H I I UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. MOTOR POWER CIRCUIT 1 c� ey J9 120V HKCARE— CONTROL INPUT 120V Hl=LINE, N1=NEUTRAL, ' z a 14 AWG C-1 BK LI ' 1 PH 2 � MTR,EXH-1 DONTi100-K12DIO FLAT 8.9 GAS Ria ® _ HK -- 15A BREAKER. D❑ NOT CONNECT TO SHUNT TRIP o' w BREAKER. SEE i 24V 8 9 0 4 OOO�® J6 1 OO OO ®OO ©7 BH-Wired to WIRED ANT a RD —Master CORE wW� 115 V L3 20 A 3 4 � r HP, 0.750 —KS (Sl-- 2 BK BK INSTALLATION SCHEMATIC - + 24V DC SCADA S SHD—(If applicable) Use shielded wir + EST 14 AWG C-2 BK LI Tl MTR:SL CONmOo-KOSD10 _ _ FOR ADDITIONAL REQ. PS-01 TERMINAL GAS USED FOR ° o - EST 115Pv� w� FLA 3.6 j N L 120V POWERED GAS AC L3 HP,0.250 H1 BK -- o DEST CAT-5 JI 15 A VALVES ONLY a E 0 PANEL LID li -- Gam— Z L7Z= DEST TO ETH 3 4 J7 120V 1 BK BK 14AWG R 1 I�aHI BK WH �aN1 Jr (3, BK HOOD GHTS C-1 BK C-2 Nl 6 Nl DC+ B�® RD-1 7 PR RO1 AR1 BBC RA-�Nl SF1 BK RA-2 7 DRY CONTACTS (SHOWN DE -ENERGIZED) 14 AWG RA-1-1 ON/OFF MAKE UP AIR INTERLOCK. - - -QAEG-- W1TH JUMPR C YW FIRE 14 AWG RA-2-1 8 N OFF NO WITH JIO JIO C YW SUP ECPM03 ECPM03 14 AWG RA-2-2 N0� C YW 9 18x18x6Box/ FACTORY WIRING SCHEMATIC CIRCUIT BOARDS RA-x RD—x 120 VAC 24 VDC RELAY RELAY NO 4 3 NO 4 3 NC 2 1 NC 2 1 COIL 8 7 COIL 8 7 COM 6 5 COM 6 5 COMPONENT LIST aTIE DESCRIPTION ST-X Stcrteer OL—X Overload C-X Contactor e PS-1 Power Iup241D:: MDP18-24A-IC RA-x 120V Relayy DPDT 34.110.01840 R0-x 24VDC Ligqht Relay 34.110.0108,0 ---YLLL.II W1K1NU FACTOR( WIRIND BK- BLACK YW- YELLOW BL- BLUE GY- GREY BR- BROWN PR- PURPLF eITI RD- RED WI+ WHITE GR- GREEN UR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GIw RD/GN STRIPE WH/BL- WH/BL STRIPE 120V I Ph— w/ control for 1 Exhaust Fan, 1 Supply Fnn, Exhaust on In Flre, Lights out In Fire, Relay On/Off with Supply Fan, F-Cs) On/Off Thermostatically Controlled. Room temperature s shipped loose for field InstMlntlon.