Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED BLD2024-1236+Manufacturer_Specifications_and_Installation_Instructions+9.19.2024_8.56.42_AM+4510274
will" The following docoata l�a� e . ' site f Dr the building inspector: ®C E APPROVED ARCHITECTURAL PLAN SET ! ❑ C E APPROVED STRUCTURAL PLAN SET ; ❑ C E REVIEWED CALCULATION PACKET ❑ E ERGY CREDIT WORKSHEET ' ❑ SI FE PLAN ❑ Cl VIL PLAN 6 ■ CITY OF EDMONDS BUILDING DEPARTYENT,2�2Y� ; C E H \ We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. Item Part # Description Wiring Item # FAN ASSEMBLIES AND THERMOSTATS A. 7W Standard Energy Efficient Fan Assembly (1) 0477654 Fan Motor, Evaporator 0142780 Fan Blade embossing toward motor B. 0411744 Standard Non-adjustable (2) Defrost Thermostat C. Optional Adj. Refrigeration Thermostat (3) LAMPS AND BALLASTS D. Ballast, Electronic (4) 0466234 2lamps 0466235 3lamps 0466236 4lamps E. Fluorescent Lamp (5) Replace with like fixtures E3 Engineering PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1/2 Technical Data Sheet /� Plan Views ( ) Merchandiser Liquid Line (in.) /s P/N 0453527 F Dimensions shown as inches and mm � Merchandiser Suction Line (in.) 7/8 NSF® Certified E3 A Delicatessen c April 2017 Precut & Packaged D Produce --- - =-- -- -_-- = --_-- 27 % 34 '/z D F DOE 2017 29 5c'o2' ce's' 04-2010 (752) 30 3/° Energy Efficiency B (781) 46'/2 --------- -- ----------------------- (1181) Compliant a calernce --- ----- - --------------- Waste Outlet Water Seal EG E F 8% (213) E H Front 4ft 6ft 811 1211 General (A) Case Length (without ends or partitions) 481/8 (1222) 721/8 (1832) 961/4 (2445) 144 3/8 (3667) NOTE.- Each end or insulated partition adds 1 inch to lineup. Maximum O/S dimension back to front (with bumper) 461/2 (1181) 461/2 (1181) 461/2 (1181) 461h (1181) Back of case to front of front panel 341/2 (876) 341/2 (876) 341h (876) 341h (876) Back of case to O/S edge of front skid rail 29 3/8 (746) 29 3/8 (746) 29 3/8 (746) 29 3/8 (746) Width of skid rail 41/2 (114) 41h (114) 41/2 (114) 41/2 (114) RH end of case to outside edge of external support 13/8 (34) 13/8(34) 13/8 (34) 13/8 (34) Distance between edges of external support and center support NA 281/2 (724) 401h (1029) 401h (1029) Distance between edges of center supports NA NA NA 44 (1118) Stub -up area between front skid rail and front panel 5 3/4 (146) 5 3/4 (146) 5 3/4 (146) 5 3/4 (146) Item Part # Description Wiring Item # Electrical Service (Electrical Field Wiring connection point) LED FIXTURES AND POWER SUPPLY (B) Length of electrical raceway 18 3/8 (467) 18 3/8 (467) 37 (940) 37 (940) F. 0501213 Power Supply ((C) RH End of case to center of farthest knockout 36 5/8 (930) 60 3/4 (1543) 84 3/4 (2153) 132 3/4 (3372) G. LED Canopy Fixture (77) ) Back of case to center of end knockout 29 5/8 (752) 29 5/8 (752) 29 5/s (752) 29 5/8 (752) Replace with like fixtures (D) RH End of case to RH end of raceway 27 5/8 (702) 515/8 (1311) 571/4 (1454) 1051/8 (2670) H. LED Shelf Fixture (8) LH End of case to LH end of raceway 21/8 (54) 21/8 (54) 21/8 (54) 21/8 (54) Replace with like fixtures Waste Outlet 0 (E) RH End of case to the center of waste outlet 241/4 (616) 241/4 (616) 241/2 (622) 721/4 (1834) LH End of case to the center of waste outlet 23 7/8 (606) 47 7/8 (1216) 713/4 (1822) 721/8 (1832) Back O/S of case to center of waste outlet 27 5/8 (702) 27 5/8 (702) 27 5/8 (702) 27 5/8 (702) �l Water Seal Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102) Schedule 40 diameter of the drip pipe 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) NOTE.- Water seal outlet must clear front skid rail,• water seal rotation in forward direction only due to low base. Refrigeration Outlet Note: Revision F: April 2017. Updated LED energy values. Other changes marked with a bar, circle or underline. 02017 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S.& CANADA 1-800-922-1919 *MEXICO 1-800-890-2900 * WWW.HUSSMANN.COM Spanish P/N 0531215 Elite E3 Delicatessen Precut & Packaged Produce Product Data Recommended Usable Cube 1(Cu Ffft) 4.72 ft3/ft (0.44 m3/m) AH" Total Display Area 2 (Sq FbTt) 3.48 ft2/ft (1.06 m2/m) ShelfArea 3 (Sq Ft/Ft) 7.08 ft2/ft (2.16 m2/m) 1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [n13/n1] 2 Computed using AHRI 1200 standard methodology: Total Display Area, ft2 [m2]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (1) row of 14-inch shelves, (1) row of 18-inch shelves and (1) row of 22-inch shelves. ESTIMATED SHIPPING WEIGHT 4 Case Solid End 4 ft 6 ft 8 ft 12 ft (each) lb (kg) 400 (181) 600 (272) 800 (363) 1000 (454) 100 (45) 4 Actual weights will vary according to optional kits included. Electrical Data (Continued) Amperes Watts 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft EcoShine II Canopy EcoShine II 0.16 0.26 0.32 0.48 19.3 31.6 38.6 58.0 EcoShine II HO 0.22 0.33 0.44 0.66 26.5 39.5 53.0 79.4 EcoShine II Rail Light -1 Row 0.08 0.12 0.16 0.25 9.9 14.1 19.8 29.7 EcoShine II Shelves 2 Rows of Shelves 0.16 0.33 0.44 0.66 26.5 39.5 53.0 79.4 3 Rows of Shelves 0.25 0.35 0.49 0.74 29.7 42.3 59.3 89.0 4 Rows of Shelves 0.33 0.47 0.66 0.99 39.5 56.4 79.1 118.6 120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 120V LED Lighting Circuit Total = Canopy Lighting + Shelf Lighting + Optional Rail Lighting 230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52 PAN 0453527_F ] HUSSMANN CORPORATION • BRIDGETON MO 63044-2483 U.S.A. * WWW.HUSSMANN.COM 5 of 12 Back of case to center of refrigeration outlet 30 3/4 (781) 30 3/4 (781) 30 3/4 (781) 30 3/4 (781) RH end of case to center of refrigeration outlet 8 3/s (213) 88 3/8 (213)(213) 8 3/8 (213) 8 3/8 (213) 2 of 12 U.S. & Canada 1-800-922-1919 * Mexico 1-800-890-2900 E3 Technical Data Sheet Fan Wiring Offtime Defrost 2 & 3 Fans 120V Neutral I Fans O Brown Band 120V Power , I Brown Band I 2 Defrost L Termination Refrigeration Thermostat Thermostat Light Blue Dark Blue To 1 Condensing f Unit Shelf Lighting Optional Shelf Harness and Light Circuits for One Row of Shelves Shelf Harness Shelf Light Circuits Connector Connector aR A G BL R BL R 5 5 WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Numbers = Parts List Item Numbers Grayed components in 12 foot models only. R = Red Y =Yellow G = Green BL = Blue BK = Black W = White e = 120V Power o = 120V Neutral -L = Field Ground = Case Ground 6 of 12 U.S. & Canada 1-800-922-1919 * Mexico 1-800-890-2900 E3 Technical Data Sheet ALL WORK SUBJECT APPROVED TO FIELD PLANS MUST BE INSPECTION FOR CODE COMPLIANCE nKi InD 011rC Elite Specialty Merchandiser Multi -deck, 3 Display Levels DOZ27" Hussmann refrigerated merchandisers configured for sale for use in the United StatesEliteE3 Energ Delicatessen Comeet or surpass the requirements of the DOE 2017 energy efficiency standards. Precut & Packaged Produce Dimensions shown as Inches and (mm). REFRIGERATION DATA E 3 23 Note: This data is based on store temperature and humidity that does not (645) exceed 75 (*F) and 55% R.H. E3t Discharge Air (°F) 29 Evaporator (°F) 21 15 3/4 (40 )) Unit Sizing (°F) 19 See Page 12 for § Average evaporator temperature shown. recommended / I Use dew point for high glide refrigerants for unit sizing. Care should be taken shelf configuration. Ile 35 to use the dew point in PT tables for /0 (889) measuring and adjusting superheat. Adjust b" evaporator pressure as needed to maintain / •° 56 discharge air temperature shown. I (1422) / BtuAr/ft - Unlit Shelves E3 31 (787) Coil Parallel 1159 22 ' Conventional 1259 (5 g) 3 Add 20 Btu/hr/ft per shey'row for fluorescent lamps. Add 10 Btu/hr/ft per sheyrow for LED Refrigeration Fan lamps. 12 Outlet DEFROST DATA E3 Li 1/4 Frequency (hr) 6 --111� 4 Defrost Water (lb/ft/day) 8 27 % (108) I (702) (+ 151/6based on case configuration and 3 product loading). ' (7 81) 12 34 Y2 OFFTIME E3 pub) 876 Temp Term (°F) 48 46 1/2 Failsafe (minutes) 40 (1181) ELEcTRic oR Gas Not Recommended Standard Defrost Thermostat Close on rise: close 48*F - open 33°F Estimated Charge ** E3 4 ft 0.9 lb 14 oz 0.4 kg CONVENTIONAL CONTROLS 6 ft 1.8 lb 29 oz 0.8 kg Low Pressure Backup Control 8 ft 1.9 lb 30 oz 0.9 kg Cl/CO* E3 12 ft 2.9 lb 46 oz 1.3 kg Temp (°F) 14/4 **This is an average for all refrigerant types. Actual refrigerant charge may vary by Indoor Unit Only, Pressure Defrost approximately half a pound (8 oz/0.2 kg). Termination (Temp °F)* 48°F *Use a Temperature Pressure Chart to determine PSIG conversions. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability. P/N 0453527 F HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. * WWW.HUSSMANN.COM 3 of 12 Light Circuits Standard Lighting 2 Rows Canopy 120V Neutral Orange or I Tan Band 120V Power I I Orange or I Tan Band W I �O BK 4 - BL Light R BL Switch W BL R R BK 5 5 5 4 BL BL BL R R 5 5 5 Optional Lighting: 1 Row Ledge or 1 Row Rail 120V Neutral Orange or I � I 120V Power Tan Band I Orange or I Tan Band w I' � BK 4 BL Light R BL Switch BL R R 5 5 5 WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Numbers = Parts List Item Numbers Grayed components in 12 foot models only. R = Red Y =Yellow G = Green BL = Blue BK = Black W = White e = 120V Power o = 120V Neutral L = Field Ground ,h = Case Ground P/N 0453527_F _JI HUSSMANN CORPORATION * BRIDGETON, MO 63044-2483 U.S.A. * WWW.HUSSMANN.COM Elite E3 Delicatessen Precut & Packaged Produce Electrical Data 4ft 6ft 8ft 12 ft Number of Fans - 7W l 2 2 3 Amperes 4ft 6ft 8ft 12 ft Evaporator Fans 120V 50Hz/60 Hz Standard Energy Efficient 0.19 0.38 0.38 0.57 230V 5OHz/60 Hz Standard Energy Efficient NA 230V 6011z Export NA 230V 5011z Export NA Cycling Anti -sweat Heaters NA Minimum Circuit Ampacity 120V 5OHz/60 Hz Standard Energy Efficient 0.39 0.58 0.58 0.77 230V 5OHz/60 Hz Standard Energy Efficient NA 230V 6011z Export NA 230V 5OHz Export NA Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V NA Electric Defrost Heaters (208V 1Ph) NA Watts 4 ft 6 ft 8 ft 12 ft 14 28 28 42 ONLY LIGHTING CONFIGURATIONS THAT ARE COMPLIANT WITH THE U.S. DEPT. OF ENERGY (DOE) 2017 REGULATION ARE AVAILABLE FOR SALE FOR USE IN THE U.S.A. Standard Lighting (T-8 fluorescent) 2 Rows Canopy 0.51 1.01 1.01 1.52 66 122 122 183 Optional Lighting (T-8 fluorescent) 1 Row Rail Lights 0.51 0.51 0.51 0.76 62 62 62 96 1 Row Ledge Lights 0.51 0.51 0.51 0.76 62 62 62 96 Optional Shelf Lighting (T-8 fluorescent) 1 Row of Shelves 0.51 0.51 0.51 0.76 62 62 62 96 2 Rows of Shelves 0.51 1.01 1.01 1.52 66 122 122 183 3 Rows of Shelves 0.76 1.53 1.53 2.28 92 184 184 274 Please note: some combinations of fluorescent lights on this case model may not be compliant with DOE 2017 and may not be available to order in the US and Canada. More lighting options are available with LED lights. The Hussmann Product Configurator will not allow lighting options that do not comply with the DOE 2017 standards. (CONTINUED) 4 of 12 U.S. & Canada 1-800-922-1919 * Mexico 1-800-890-2900 E3 Technical Data Sheet Elite E3 Delicatessen Precut & Packaged Produce EcoShine II LED Canopy Lighting - 2 Row - - - - - - - - - - - - - - - - - - - - - I I I I I I BL I I BK� BK © BL i �W�`--W 6O R I I -W W R 4 Ft Case i i 6 Ft or 8 Ft Case R I I R R I BL I I BL BL I 1 RL 7 I I RL 7 RL O I RBL O I I RL 7 RL 7 I I I I I L------------- - - - - -J L------------------------------ - - - - -J r---------------------------------------------------------- I - BK� I I r-W I 12 Ft Case tw © BL R I I I I R BL I I R R I BL BL R L R L 7 R L 7 < R L 7 I I I L--------------------------------------------------------- WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Numbers = Parts List Item Numbers R = Red Y =Yellow G = Green BL = Blue BK = Black W = White e = 120V Power o = 120V Neutral -L = Field Ground �-h = Case Ground 7 of 12 1 8 of 12 U.S. & Canada 1-800-922-1919 * Mexico 1-800-890-2900 BLD2024-1236 E3 Technical Data Sheet Z ? O I Q o 0 J f� t) Lu Q m U l� W Q o W p Z � � U 0 to o z �LO Ln V 0 LU Q0C) 00 U � LLI � LUwoL0 = z 0 W W Z J w o V z� N J O) a CD 0 W6' (h ix z N w JCD 0z L010� (0O v O_ Z w co C) N Q<M Z F Q N 2 � o CD F- C6 N rn lr) Y FOR KEY MECHANICAL USE ONLY M M M M M 1 (n z O W 0Y z O F- 0_ W 0 W Q 0 J J Q c~IECEIVED Z Sep 19 2024 W DEVCITY OF EDMONDS ELOPMENT SERVICES U) DEPARTMENT Q U o I Q O VJ 0 U) Z IIJ 0 z �_ G � VJ Q 0 w w z U U � M U U 00 a_ 0- o-) LLI DATE: 09/18/2024 PROJ# 1 23748-00 DRAFTER IBFC REVIEWED BY I ---- SHEET SIZE I Arch E1 SCALE I AS NOTED KM PHONE 1 +1 (253) 872-7392 CUT SHEETS SHEET NUMBER: %_ R6.0-./