APPROVED BLD BLD2024-1066+MECH PLANS+8.13.2024_10.38.47_AM+4437054BASE UNIT DIMENSIONS-48SDO42-060 1 N [ 0 1 W• W W• W .1. I �I 0 NWW W p W 1MW• W REQUIRED CLEARANCES TO COMBUSTIBLE MATL MILLIMETERS [IN] TOP OF UNIT.............................................355.6 114.001 DUCT SIDE OF UNIT.........................................50.8 12.001 SIDE OPPOSITE DUCTS.....................................355.E 114.001 BOTTOM OF UNIT ......................................... 12.7 [0.50] FLUE PANEL..............................................914A 136.001 NEC. REQUIRED CLEARANCES. MILLIMETERS [IN] BETWEEN UNITS, POWER ENTRY SIDE ........................1066.8 [42.001 UNIT AND UNGROUNDED SURFACES, POWER ENTRY SIDE .......... 914.0 [36.00] UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES, POWER ENTRY SIDE....................1066.8 [42.001 1193. - 1090.6 [d2. 941� FIELD ENTRY [47.00]9 SERVICE PORT 23,p [0.9ll [44.221 LEFT SIDE VIEW 402.0 [15.831 117.7 [4.631 87.2 - 13.431 1i3.831 REAR VIEW REQUIRED CLEARANCE FOR OPERATION AND SERVICING MILLIMETERS [IN] EVAP. COIL ACCESS SIDE ................................. 94.0 [36 .00] POWER ENTRY SIDE.......................................1066.8 [42.001 (EXCEPT FOR NEC REQUIREMENTS) UNIT TOP.............................................1219.2 [48.001 SIDE OPPOSITE DUCTS.....................................914.0 [36.001 DUCT PANEL..............................................304.8 [12.001, WMINIMUM DISTANCESA F UNIT IS PLACED LESS THAN 304.8 (12.001 FROM WALL SYSTEM,THEN SYSTEM PERFORMANCE MAYBE COMPROMISED. DIMENSIONS IN [] ARE IN INCHES 115.4 28.6[1.13I DIA. N.O. POWER ENTRY 22.2[0.881 DIA. HOLE - CONTROL ENTRY A" [14.823.8 ] 4 2 dt]G 506.1 [19. 93] 397.1 Z 363.7 114.32I I15.63] [ I 258.7 [10.191 Oo. I2. 7 1 .681 ,2g.0 % COMPRESSOR, BLOWER, GAS SECTION 46.6 [1.84] 12.95] 9 ELECTRICAL ACCESS PANEL 52.8 2.4 1226.3 [1.08I 2.85] [48.28) 142.4 5.61] FRONT VIEW -12. 1[0.5.0 GAS ENTRY [0.20: 87.2 RIGHT SIDE VIEW 13.431 A07375 UNIT ELECTRICAL CHARACTERISTICS UNIT WEIGHT UNIT HEIGHT IN. [MM] `A" CENTER OF GRAVITY IN. [MM] Ib kg X Y Z 48SDO42 208/230-1-60, 208/230-3-60, 460-3-60 450 204.1 40.98 [1041] 21.0 [533] 21.0 [533] 17.1 [434] 48SDO48 208/230-1-60, 208/230-3-60, 460-3-60 48 217.7 46.98 [1193] 21.0 [533] 20.0 [508] 17.4 [442] 48SDO60 208/230-1-60, 208/230-3-60, 460-3-60 484 219.5 46.98 [1193] 21.0 [533] 20.0 [508] 17.6 [447] +(E) Economizer = 50lbs (E) RTU ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE I LOUVER PANEL 3-7/I6� 1 I6 [71.4] 111 I 5-15/16 14o4.81 e1 OUTDOOR COIL INDOOR COIL. 2 150.81� O o % DRAIN OUTLET - � COMPAES SOR 3/74" [19.11N.P.T. I2-15/I6 PANEL X 7/8" [22.2] DEEP [328.6] 3-II/I6 1 22.11 [93. 7] LEFT SIDE VIEW u 6-13/I6 3.01 rOP VIEW 000R colt - 47 4-I/2 [1193.8] [II4.3] LOUVER PANEL o• o• LOWS PANEL d8-3/16 1224.01 FRONT VIEW 1-1/8" 128.61 DIA. N. POWER ENTRY ELECTRICAL ACCESS PANEL 7/8" [22.2] DIA. HOLE R CONTROL ENTRY [123.8] A4-7/8 •E 21-7/ ,J [555.8 16-I/d •2• 1 [d12.] I7-5/8 12-I/8 [447] 308.0 p 5-9/I6 1141.31 2 152.41-1/I6 I -13/I6 (N) RTU APPROVED NOTE: I. ALL TABLE DATA RELEVANT FOR ALL FACTORY INSTALLED OPTIONS EXCEPT ECONOMIZER. 2. - INDICATES ALL FIOP CODES FOR THE MODELS LISTED. RWURED CLENVMCES TO CaeuSTELE NIATL 1111 TOP OF UNIT ................................ INCHES 14 [355. 61 DUCT SIDE OF UNIT... ................. 2 150:81 SIDE OPPOSITE DUCT S. ................14 NIT ............................ BOTTOM OF UNIT: L355.61 I/2 112. 7] FLUE PANEL ................................. 36 1914.41 NEC. RECURED CLEARANCES. INCHES [MM1 NETWEEN UNITS, POWER ENTRY SIDE.............42 11066.81 UNIT AND UNGROUNDED SURFACES, POWER ENTRY SIDE... 361414.01 UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES, POWER ENTRY SIDE......... 42 11066.81 R""AED CLEARANCE III OMTION AM SEAVICNG INCHES IMM] EVAP. COIL ACCESS SIDE....................36 [91d. 01 POWER ENTRY SIDE .......................... (EXCEPT FOR NEC REOUTAEMENTSI 42 [1066.8] UNIT TOP. [1219. 2] SIDE OPPOSITE DUCTS.......................36 [91d.0] DUCT PANEL ................................ 12 1304.81, MINIMUM DISTANCES:IF UNIT IS PLACED LESS THAN 12 1304.81 FROM WALL SYSTEM,THEN SYSTEM PERFORMANCE MAYBE COMPROMISED. DIMENSIONS IN 11 ARE IN MM LOUVER PANEL 5- 7/8 I d03.2] O 1168.31 •8• - 112" [12. 71 N, P,T 3/I6 GAS ENTRY 14.81 3-3/8 187.31 RIGHT SIDE VIEW PLANS MUST BE ON JOB SITE LOUVER PANEL SUPPLY RETURN DUCT DUCT OPENING OPENING c [3465 /181 13-718 �1 1352.41 4� [352.41 REAR VIEW SD5900-4 A 24-099 Point Edwards Condos Edmonds - 4T RTU ASCE 7-16 Chapter 11- Seismic Ground Motion Values Conterminous 48 States 2016 ASCE 7 Standard Latitude = 47.8043 Longitude =-122.3901 Data are based on a 0.05dea grid soacinQ Mapped Spectral Acceleration Values Spectral Response Accelerations Design Spectral Response Accelerations SMs=Fax Ss andSM1=FvxS1 SDs=2/3xSMS and SD1=2/3xSM1 Site Class B - Fa = 1.2 ,Fv = 1.0 Site Class D - Fa = 1.2 ,Fv = NA Site Class D - Fa = 1.2 ,Fv = NA Period Sa Period Sa Period Sa (sec) (g) (sec) (g) (sec) (g) 0.2 1.284 (Ss, Site Class B) 0.2 1.54 (SMs, Site Class D) 0.2 1.027 (SDs, Site Class D) 1 0.451 (S1, Site Class B) 1 1 NA (SM1, Site Class D) 1 NA (SD1, Site Class D) ASCE 7-10 Chapter 13 - Seismic Demands on Nonstructural Elements Seismic design force F _ 0.4apSDSWp 1+2z h Max Fp= 1.6SDsIpWp p p p SIDS = Ip= 1.0 p (RP / I) ( /) ( Min FP = 0.3 SDS I W S 1.026667 Concurrent vertical force Fp V _ ± 0.2 SIDS Wp Mechanical Unit Wp ap RP Z h Fp min FP Fp,max Use FP Fp,V HVAC RTU 550 lb 2.5 6.0 20.0 ft 20.0 ft 169 lb 282 lb 903 lb 282 lb 113 lb Shear to be resisted by all anchors Value of "0 lb" indicates that Vbase = 0•7 Fp weight of unit is sufficient to Shear per anchor Mechanical Unit Vbase 4 anchors 6 anchors HVAC RTU 198 lb F 49 lb 33 lb Uplift to be resisted by each line of anchors FLPIift = 0.7 (FP hcentroid / wbase,min t Fp v / 2) - 0.6 Wp / 2 Mechanical Unit wp Fp Fpv hcentroid wbase,min Fuplift HVAC RTU 550 lb 282 Ib 113 Ib 30.0 in 44.0 in 9 lb BARTLEY PAW LAK STRUCTURAL =ENGINEERS 2021 IEBC 502.4 resist uplift due to overturning moments. Typical roof framing consists of joists at 24"oc. Dead Load = 15 psf Snow Load = 25 psf (E) RTU = 500 Ibs (36psf) (N) RTU = 542 Ibs (37psf) Total load applied is < 5% additional weight of total gravity load to any framing member. CALCULATIONS City Of Edmonds Building Department Work MECH- RTU Address 51 PINE ST #308 Owner RICKER Approved Date 8/19/2024 Building Official �� Codntcr Permit Number BLD2024-1066 ----------------- BARTLEY PAW LAK STRUCTURAL .ENGINEERS 2731 77th Ave SE, #100 Mercer Island, WA 98040 Phone:206.456.3071 Fax:206.456.3076 www.BP-SE.com P. P�S, pF wA-7 7�23024 VAL E PROJE - U) L Z 2i Z o Ow W CN Z O W O U Q Q UJ }; �� U/ W Q I.�^L O E Q r / w W Z 0^ 0- REVISION 7/16/24 24-099 DATE JOB # TCB FPP DESIGN CHECKED TCB AS NOTED DRAWN SCALE AHJ STAMP RECEIVED Aug 15 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEETTM-E RTU FRAMING STRUCTURAL CALCULATIONS SHEET NO. CALCULATIONS S-1