Loading...
APPROVED BLD BLD2024-1050+MECH PLANS+8.13.2024_10.30.26_AM+4436999BASE UNIT DIMENSIONS-48SDO42-060 355.8 355.8 86.0 [14. 01] [1] [3.39] -W 3[142.7 3.49] 10.4 RETURN SUPPLY 12.111 .. IJ /'---- IIII OPTIONAL OPTIONAL I� III RETURN SUPPLY IIII [�6.01] IIII AIR OPENING �` OPENING IIII IIII I �I I IIII _---JIII III III II III III III rr OUTDOOR COIL III ®\�)® III �83.171 III III • Y I IF _ _i�i 113.5 _ ------------_- [6.831 INDOOR COIL � 3 TOP VIEW UTDOOR COIL REQUIRED CLEARANCES TO COMBUSTIBLE MATL. MILLIMETERS [IN] TOP OF UNIT.............................................355.6 114.001 DUCT SIDE OF UNIT.........................................50.8 12.00] SIDE OPPOSITE DUCTS.....................................355.6 [14.00I BOTTOM OF UNIT .......................................... 12.7 10.50] FLUE PANEL..............................................914.4 136.00 NEC. REQUIRED CLEARANCES. MILLIMETERS [IN] BETWEEN UNITS, POWER ENTRY SIDE........... 1066.8 [42.00] UNIT AND UNGROUNDED SURFACES, POWER ENTRY SIDE..........914.0 [36.00] UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES, POWER ENTRY SIDE....................1066.8 [42.001 1193.9 1090.E I47.00] [42.94] FIELD ENTRY SERVICE POAT� [0. 91] 402.0 [15.831 81.2 [3.43 113.831 M A31 REAR VIEW REQUIRED CLEARANCE FOR OPERATION AND SERVICING MILLIMETERS [IN I EVAP. COIL ACCESS SIDE..................................94.0 136 .00 POWER ENTRY SIDE.......................................1066.8 [42.001 (EXCEPT FOR NEC REQUIREMENTS UNIT TOP...............................................1219.2 [48.001 SIDE OPPOSITE DUCTS.....................................914.0 136.001 DUCT PANEL..............................................304.8 [12.00]= *MINIMUM DISTANCESA F UNIT IS PLACED LESS THAN 304.8 112.001 FROM WALL SYSTEM,THEN SYSTEM PERFORMANCE MAYBE COMPROMISED. DIMENSIONS IN 11 ARE IN INCHES n s.4 28.6[1.131 DIA. N.0 POWER ENTR 22.2[0.88I DIA. HOLE CONTROL ENTRY " [123.8 d.8d] 620.2 �� 124. 411 CG III 506.1 [19. 93] 391.1 2 [15.631 • 363.1 258.1 ®` [14. 321 [10.19] DRAIN OUTLET 42.7 X 1'YN "8' N.P.T. [1.681 46.E X 22. 0[0.87] DEEP COMPRES 329.0 SO, BLOWER, GAS SECTION [1.84] [12.95] d ELRECTRICAL ACCESS PANEL 52 8 72.1 1226.3 [2.081 1123.1 [2.85I [d8.28] 142,4 [44.M [5.61I LEFT SIDE VIEW FRONT VIEW -12.7[0.5I N.P.T. 5.0 GAS ENTRY [0.20: 87.2 RIGHT SIDE VIEW 13.431 A07375 UNIT ELECTRICAL CHARACTERISTICS UNIT WEIGHT UNIT HEIGHT IN. [MM] A" CENTER OF GRAVITY IN. [MM] Ib kg X Y Z 48SDO42 208/230-1-60, 208/230-3-60, 460-3-60 450 204.1 40.98 [1041] 21.0 [533] 21.0 [533] 17.1 [434] 48SDO48 208/230-1-60, 208/230-3-60, 460-3-60 480 217.7 46.98 [1193] 21.0 [533] 20.0 [508] 17.4 [442] 48SDO60 208/230-1-60, 208/230-3-60, 460-3-60 48;J 219.5 46.98 [1193] 21.0 [533] 20.0 [508] 17.6 [447] (E) RTU ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE 3 187.31 2-13/I6 [71.4] 111 I 514o4-I5/e1I6 . LW OUTDOOR COIL INDOOR COIL 2 50.81� LOUVER PANEL O L- DAAIN OUTLET COMPAES SOR 3/4" [19.11N.P.T. I2-IS/I6 PANEL X 7/8" [22.2] DEEP 3-11/I6 [�122/41 193.71 LEFT SIDE VIEW U 6113.1E 3.01 rOP VIEW 000R co1L 47 4-1/2 (1193.8] [II4.31 LOUVER PANEL O O • LOWE PANEL d8-3/16 11224.01 FRONT VIEW 1-111" 121,'1 DIA. K. POWER ENTRY ELECTRICAL ACCESS PANEL R 7/8" [22.21 DIA. HOLE •® CONTROL ENTRY 4-7/a [123.8] ,J [555.6] 1-1/d 1] .2. 6 [d12. I7-5/8 12-1/8 [447. 7] 308.0 R 9. 1.1E T%31 211.1E 52.41 I-13/I6 146.0] (N) RTU APPROVED ®-® ° ' NOTE: I. ALL TABLE DATA RELEVANT FOR ALL FACTORY INSTALLED OPTIONS EXCEPT ECONOMIZER. 2. - INDICATES ALL FIOP CODES FOR THE MODELS LISTED. RWIAIED CLEAEANDE6 TO Ca IXISTELE MATL. INCHES IMMI TOP OF UNIT ................................ Id [355. DUCT SIDE OF UNIT... ................. B1 2 [50.8] SIDE OPPOSITE DUCT S. ................14 BOTTOM OF UNIT ............................I/2 [355.6] FLUE PANEL ................................. 36 1914.41 NEC. REQUIRED CLEARANCE& INCHES [NM] NETWEEN 'NOW ENTRY SIDE...I ENTN....42 UNIT AND UNGROUNDED SURFACES, POWER ENTRY ..31 I4 SIDE...36[91d.01 UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES, POWER ENTRY SIDE......... 42 11066.81 r8" LLEMANLE III OMT10N AM SEAVICNG INCHES IMM] EVAP. COIL ACCESS SIDE....................36 [911:11 POWER ENTRY SIDE .......................... (EXCEPT FOA NEC REOUTAEMENTSI 42 [1066.8] UNIT TOP .................................. 48 [1219. 21 SIDE OPPOSITE DUCTS ....................... 36 [91/.0] DUCT PANEL ................................ 12 1304.81, MINIMUM DISTANCES:IF UNIT IS PLACED LESS THAN 12 1304.81 FROM WALL SYSTEM,THEN SYSTEM PERFORMANCE MAYBE COMPROMISED. DIMENSIONS IN 11 ARE IN MIN LOUVER PANEL 15-7/8 403.21 L 6-5/8 O 1168.31 •8• - 1/2" [1.71 N, I 3/I6 GAS ENTR2Y [4 8] 3-3/e 87. 31 RIGHT SIDE VIEW PLANS MUST BE ON JOB SITE LOUVER PANEL SUPPLY HE UAN DUCT DUCT OPENING OPENING 110 11- 13-7/B _J [3465 /181 13-7/8 �1 1352.41 4� [352.41 REAR VIEW SD5900-4 A 24-099 Point Edwards Condos Edmonds - 4T RTU ASCE 7-16 Chapter 11- Seismic Ground Motion Values Conterminous 48 States 2016 ASCE 7 Standard Latitude = 47.8043 Longitude =-122.3901 Data are based on a 0.05dea Rrid soacinR Mapped Spectral Acceleration Values Spectral Response Accelerations Design Spectral Response Accelerations SMs=FaxSsandSM1 FvxS1 SDs=2/3XSMSand SD1=2/3xSM1 Site Class B - Fa = 1.2 ,Fv = 1.0 Site Class D - Fa = 1.2 ,Fv = NA Site Class D - Fa = 1.2 ,Fv = NA Period Sa Period Sa Period Sa (sec) (g) (sec) (g) (sec) (g) 0.2 1.284 (Ss, Site Class B) 0.2 1.54 (SMs, Site Class D) 0.2 1.027 (SDs, Site Class D) 1 0.451 (S1, Site Class B) 1 1 NA (SM1, Site Class D) 1 NA (SD1, Site Class D) ASCE 7-10 Chapter 13 - Seismic Demands on Nonstructural Elements Seismic design force F _ 0.4 ap Sps Wp 1 + 2 z h Max FP = 1.6 SD5 1p Wp Ip = 1.0 p R I) ( /) Min F= 0.3 S I W S 1.026667 ( p/ p p DS p p SIDS = Concurrent vertical force Fp v = ± 0.2 SDS Wp Mechanical Unit Wp al) RP z h Fp min FP Fp,max Use FP Fp,V HVAC RTU 550 lb 2.5 6.0 20.0 ft 20.0 ft 169 lb 282 lb 903 lb 282 lb 113 lb Shear to be resisted by all anchors Value of "0 lb" indicates that Vbase = 0.7 Fp weight of unit is sufficient to Shear per anchor Mechanical Unit Vbase 4 anchors 6 anchors HVAC RTU 198 lb 49 lb 33 lb Uplift to be resisted by each line of anchors Fuplift = 0.7 (FP hcentroid / wbase,min t Fp v / 2) - 0.6 Wp / 2 Mechanical Unit wp Fp Fpv hcentroid wbase,min FEPIift HVAC RTU 550 lb 282 lb 113 IbI 30.0 in 44.0 in 9 lb BARTLEY PAW LAK STRUCTURAL i_ENGINEERS 2021 IEBC 502.4 resist uplift due to overturning moments. Typical roof framing consists of joists at 24"oc. Dead Load = 15 psf Snow Load = 25 psf (E) RTU = 530 Ibs (38psf) (N) RTU = 542 Ibs (37psf) Total load applied is < 5% additional weight of total gravity load to any framing member. CALCULATIONS �BARTLEY PAW LAK �STRUCTURAL ENGINEERS 2731 77th Ave SE, #100 Mercer Island, WA 98040 Phone:206.456.3071 Fax:206.456.3076 www.BP-SE.com P. P,� wASy1� 702e4� VAL E PROJE nC U) G Z Z o O w r` o Z UJ O W O U Q Q UJ }; U/UJ 0 'v^, Q O ^ L E Q / w W Z O n REVISION City Of Edmonds Building Department Work MECH- RTU Address 51 PINE ST UNIT 307 .----------------------------------- ----------------------------------------------------------------- Owner GODDARD - ------------------------------------------------ Approved Date 08/19/2024 Building Official Elrl& 7/16/24 24-099 Permit Number BLD2024-1050 DATE JOB# TCB FPP DESIGN CHECKED TCB AS NOTED DRAWN SCALE AHJ STAMP RECEIVED Aug 15 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEETTfTLE RTU FRAMING & STRUCTURAL CALCULATIONS SHEET NO. S-1 CALCULATIONS