Loading...
APPROVED BLD RESUB 1-BLD2024-0796+Manufacturer_Specifications_and_Installation_Instructions+6.27.2024_3.19.10_PM+4348014I:3A�3��IYZ�d1�'I:� Fig. 1—Unit 48VG u t A09033 Single -Packaged Products with Energy -Saving Features and Pmon® (R-410A) refi•igerant. • Up to 16.0 SEER2 • 11.5 EER2 • 81%AFUE • Meets Energy Star requirements • Direct Spark Ignition • Factory -Installed TXV • Multi -speed ECM Blower Motor -Standard • Sound Levels as low as 70dBA • Two Stage Cooling • Two Stage Heating (208/230 VAC models) • Two Stage Dehumidification Feahue • Cabinet air leakage of 2.0% or less at .5 in. W.C. when tested in accordance with ASHRAE standard 193. Features/Benefits One-piece heating and cooling units with low sound levels, easy installation, low maintenance, and dependable performance. Puron Refrigerant is Carrier's unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does not contain chlorine that can hams the ozone layer. Puron refi•igerant is in service in millions of systems proving highly reliable, environmentally sound performance. Easy Installation Factory -assembled package is a compact, fully self-contained, combination gas heating/electric cooling unit that is prewired, pre -piped, and pre -charged for minimum installation expense. These units are RESUB Jun 28 2024 clTr oc EDMONDs DEVELOPMENT SERVICES DEPARTMEM Turn to the experts available in a variety of standard and optional heating/cooling size combinations with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications. Innovative Unit Base Design On the inside a high-tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging. Convertible duct configuration Unit is designed for use in either downflow or horizontal applications. Each unit is converted from horizontal to downflow and includes rivo horizontal duct covers. Doi;inflow operation is provided in the field to allow vertical ductwork connections. The basepan seals on the bottom openings to ensure a positive seal in the vertical airflow mode. Efficient Operation High -efficiency design offers SEER2 (Seasonal Energy Efficiency Ratios) of up to 16.0, 11.5 EER2, and AFUE (Annual Fuel Utilization Efficiency) ratings as high as 81%. Energy -saving, direct spark ignition saves gas by operating only when the room thermostat calls for heating. Standard units are famished with natrral gas controls. A low-cost field installed kit for propane conversion is available for all units. Low NOx units are designed for California installations and meet 40 ng/J NOx emissions. Cau be installed in air quality management districts with a 40 ng/J NOx emissions requirement. Durable, dependable components Compressors have two stages of cooling and are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Each compressor also has vibration isolation to provide quieter operation. All compressors have internal high pressure and overcurrent protection. Monoport inshot but•ners produce precise air -to -gas mixture, which provides for clean and efficient combustion. The large monoport on the inshot (or injection type) burners seldom, if ever, requires cleaning. All gas furnace components are accessible in one compartment. Turbo-tubularT"' heat exchangers are constucted of stainless steel for con•osion resistance and optimum heat transfer for improved efficiency. The tubular design permits hot gases to make multiple passes across the path of the supply ah•. In addition, dimples located on the heat exchanger walls force the hot gases to stay in close contact with the walls, improving heat transfer. Multi -speed ECM Blower Motor is standard on all models. Higlt Efficiency 2-Speed Inducer Motor• on single phase models. 48VG-K: Product Data SAP ORDERING NO. NOMINAL COOLING CAPACITY (Btuh) NOMINAL HEATING INPUT (Btuh) VOLTS -PHASE (60 HZ) APPROX SHIP WT (LB) 48VG-K240403 24,000 40,000 208/230-1 352 48VG-K240603 24,000 60,000 208/230-1 352 48VG-K360603 36,000 60,000 208/230-1 455 48VG-K360605 36,000 60,000 208/230-3 455 48VG-K360606 36,000 60,000 460-3 455 48VG-K360903 36,000 90,000 208/230-1 455 48VG-K360905 36,000 90,000 208/230-3 455 48VG-K360906 36,000 90,000 460-3 455 48VG-K480903 48,000 90,000 208/230-1 500 48VG-K480905 48,000 90,000 208/230-3 500 48VG-K480906 48,000 90,000 460-3 500 48VG-K481153 48,000 115,000 208/230-1 500 48VG-K481155 48,000 115,000 208/230-3 500 48VG-K481156 48,000 115,000 460-3 500 48VG-K481303 48,000 127,000 208/230-1 500 48VG-K481305 48,000 130,000 208/230-3 500 48VG-K481306 48,000 130,000 460-3 500 48VG-K600903 60,000 90,000 208/230-1 520 48VG-K600905 60,000 90,000 208/230-3 520 48VG-K600906 60,000 90,000 460-3 520 48VG-K601153 60,000 115,000 208/230-1 520 48VG-K601155 60,000 115,000 208/230-3 520 48VG-K601156 60,000 115,000 460-3 520 48VG-K601303 60,000 127,000 208/230-1 520 48VG-K601305 60,000 130,000 208/230-3 520 48VG-K601306 60,000 130,000 460-3 520 Low NOx Units 48VGNK240403 24,000 40,000 208/230-1 352 48VGNK240603 24,000 60,000 208l230-1 352 48VGNK360603 36,000 60,000 208/230-1 455 48VGNK360605 36,000 60,000 208/230-3 455 48VGNK360606 36,000 60,000 460-3 455 48VGNK360903 36,000 90,000 208/230-1 455 48VGNK360905 36,000 90,000 208/230-3 455 48VGNK360906 36,000 90,000 460-3 455 48VGNK480903 48,000 90,000 208/230-1 500 48VGNK480905 48,000 90,000 208/230-3 500 48VGNK480906 48,000 90,000 460-3 500 48VGNK481153 48,000 115,000 208/230-1 500 48VGNK481155 48,000 115,000 208/230-3 500 48VGNK481156 48,000 115,000 460-3 500 48VGNK481303 48,000 127,000 208/230-1 500 48VGNK481305 48,000 130,000 208(230-3 500 48VGNK481306 48,000 130,000 460-3 500 48VGNK600903 60,000 90,000 208/230-1 520 48VGNK600905 60,000 90,000 208/230-3 520 48VGNK600906 60,000 90,000 460-3 520 48VGNK601153 60,000 115,000 208/230-1 520 48VGNK601155 60,000 115,000 208/230-3 520 48VGNK601156 60,000 115,000 460-3 520 48VGNK601303 60,000 127,000 208/230-1 520 48VGNK601305 60,000 130,000 208/230-3 520 48VGNK601306 60,000 130,000 460-3 520 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 48VG-K: Product Data AHRI* Capacities Cooling Capacities and Efficiencies Unit Size Nominal Tons Standard CFM (High /Low Stage) Net Cooling Capacities - Btuh (High Stage) EER2 ate.. SEER2t 24 2 800 / 600 22200 11.5 15.2 36 3 1200 ! 900 34800 11.5 15.2 48 4 1600 / 1200 46500 11.8 16.0 60 5 1750 / 1200 56000 11.5 15.2 LEGEND dB -Sound Levels (decibels) db-Dry Bulb SEER Seasonal Energy Efficiency Ratio wb-Wet Bulb COP -Coefficient of Performance * Air Conditioning, Heating &Refrigeration Institute. **At "A" conditions-80°F (26.7°C) indoor db/67°F (19.4°C) indoor• wb & 95°F (35°C) outdoor db. f Rated in accordance with U.S. Government DOE Department of Energy) test procedures and/or AHRI Standuds 210/240. Notes: 1. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard: 80°F (26.7°) db, 67°F wb (19.4°C) indoor entering-ah� temperature and 95°F db (35°C) outdoor entering -air temperature. 2. Before purchasing this appliance, read important energy cost and efficiency information available from AHRIdirectory.org. Heating Capacities and Efficiencies Unit Size Heating Input (Btuh) Output Capacity Temperature Rise Temperature Rise AFUE (%) HighlLow (Btuh) High I Low Range High °F (°C) Range Low °F (°C) 24040 40,000 / 26,000 33,000 / 22,000 25-55 (14-31) 25-55 (14-31) 81.0 24060 60,000 / 39,000 49,000 / 32,000 25-55 (14-31) 25-55 (14-31) 81.0 36060 36090 48090 90,000 / 58,500 74,000 / 48,000 35-65 (19-36) 35-65 (19-36) 81.0 60090 48115 60115 115,000 / 75,000 94,000 / 62,000 30-60 (17-33) 30-60 (17-33) 81.0 48130 127,000 / 84,500 104,000 / 70,000 35-65 (19-36) 35-65 (19-36) 81.0 60130 LEGEND AFUE -Annual Fuel Utilization Efficiency NOTE: Before purchasing this appliance, read important energy cost and efficiency information available from AHRIdirectory.org. NOTE: 460 VAC urvts are single stage heat only. A -Weighted Sound Power Level (dBA) Unit Size Sound Ratings (dBA) Typical Octave Band Spectrum (dBA without tone adjustment) 125 250 500 1000 2000 4000 8000 24 70 54.9 58.1 57.9 60.1 55.3 54.5 47.4 36 73 62.5 65.5 67.5 68.0 65.5 60.0 52.5 48 72 60.0 63.5 66.0 67.0 63.5 58.5 49.5 60 75 69.0 67.0 69.0 68.0 65.0 61.5 54.0 NOTE: Tested incompliance with AHRI 270 but not listed with AHRI. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Physical Data UNIT SIZE 24040 24060 36060 36090 48090 48115 48130 60090 60115 60130 NOMINAL CAPACITY (ton) 2 2 3 3 4 4 4 5 5 5 SHIPPING WEIGHT** Ib. 352 352 455 455 500 500 500 520 520 520 SHIPPING WEIGHT** (kg) 160 160 206 206 227 227 227 236 236 236 COMPRESSORS 2-Stage Scroll Quantity 1 REFRIGERANT (R-410A) Quantity Ib. 7.05 7.05 8.1 8.1 10.8 10.8 10.8 12.1 12.1 12.1 Quantity (kg) 3.2 3.2 3.7 3.7 4.9 4.9 4.9 5.5 5.5 5.5 REFRIGERANT METERING DEVICE TXV OUTDOOR COIL Rows...Fins/in. 1..21 1...21 2...21 2...21 2...21 2...21 2...21 2...21 2...21 2...21 Face Area (sq ft) 13.6 13.6 13.6 13.6 19.4 19.4 19.4 21.4 21.4 21.4 OUTDOOR FAN NominalCFM 2500 2500 3000 3000 3300 3300 3300 3600 3600 3600 Diameter in. 24 24 26 26 26 26 26 26 26 26 Diameter (mm) 609.6 609.E 600.4 600.4 660.4 660.4 660.4 660.4 660.4 660.4 Motor Hp (Rpm) 1/12 (810) 1/12 (810) 1/5 (810) 1/5 (810) 1/5 (810) 1/5 (810) 1/5 (810) 1/5 (810) 1/5 (810) 1/5 (810) INDOOR COIL Rows...Fins/in. 3...17 3...17 3...17 3...17 3...17 3...17 3...17 3...17 3...17 3...17 Face Area (sq ft) 3.7 3.7 4.7 4.7 5.7 5.7 5.7 5.7 5.7 5.7 INDOOR BLOWER Nominal Low Stage Cooling Airfow (Cfm) 600 600 900 900 1200 1200 1200 1200 1200 1200 Nominal High Stage Cooling Airflow (Cfm) 800 800 1200 1200 1600 1600 1600 1750 1750 1750 Size in. 10x10 10x10 11x10 11x10 11x10 11x10 11x10 11x10 11x10 11x10 Size (mm.) 254x254 254x254 279.4x254 279.4x254 279.4x254 279.4x254 279.4x254 279.4x254 279.4x254 279.4x254 Motor HP (RPM) 1/2 (1050) 1/2 (1050) 3/4 (1000) 3/4 (1000) 1.0 (1075) 1.0 (1075) 1.0 (1075) 1.0 (1075) 1.0 (1075) 1.0 (1075) FURNACE SECTION* Burner Orifice No. (Qty...Drill Size) Natural Gas (Factory Installed) 2...44 3...44 3...44 3...38 3...38 3...33 3...31 3...38 3...33 3...31 Propane Gas 2...55 3...55 3...55 3...53 3...53 3...51 3...49 3...53 3...51 3...49 HIGH-PRESSURE SWITCH 650 +/_ 15 (psig) Cut-out Reset (Auto) 420 +/- 25 LOSS-OF-CHARGE/LOW-PRESSURE 5p +/_7 SWITCH (psig) cut-out Reset (auto) g5 +/- 7 DUCT RETURN -AIR FILTERSj'$ Throwaway Size in. 20x20x1 20x24x1 24x30x1 (mm) 508x508x25 508x610x25 610x762x25 24x36x1(610x914x25) "`Based on altitude of 0 to 2000 ft (0-610 m). j�Required filter sizes shown aze based on the larger of the AHRI (Air Conditioning Heating and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway type. Air filter pressure drop for non-standard filters must not exceed 0.08 IN. W.C. $If using accessory filter rack refer to the filter rack installation instructions for correct filter sizes and quantity.