APPROVED BLD PLN BLD2024-1004+Site_Plan+7.24.2024_4.54.05_PM+4399987LEGEND
ACU
AIR CONDITIONING UNIT
AFF
ABOVE FINISHED FLOOR
AHJ
AUTHORITY HAVING JURISDICTION
AHU
AIR HANDLING UNIT
BDD
BACKDRAFT DAMPER
BHP
BRAKE HORSEPOWER
BTUH
BRITISH THERMAL UNIT PER HOUR
C
COMMON
CAP
CAPACITY
CC
COOLING COIL
CD
CEILING DIFFUSER
CFM
CUBIC FEET PER MINUTE
CLG
CEILING, COOLING
CO
CLEANOUT
COMB
COMBUSTION
CONT
CONTINUE, CONTROL
CONTR
CONTRACTOR
COP
COEFFICIENT OF PERFORMANCE
CWS
CHILLED WATER SUPPLY
CWR
CHILLED WATER RETURN
D
DIAMETER
DB
DRY BULB, DECIBEL
DEG
DEGREE
DIM
DIMENSION
DISCH
DISCHARGE
DN
DOWN
EA
EXHAUST AIR
EAT
ENTERING AIR TEMPERATURE
EER
ENERGY EFFICIENCY RATIO
EF
EXHAUST FAN
EFF
EFFICIENCY
EG
EXHAUST GRILLE, ENGINE
GENERATOR
ELEC
ELECTRIC
EQUIV
EQUIVALENT
ESP
EXTERNAL STATIC PRESSURE
EXH
EXHAUST
EXT
EXTERIOR, EXTERNAL
F
FAHRENHEIT
FD
FIRE DAMPER
FCU
FAN COIL UNIT
FLR
FLOOR
FPM
FEET PER MINUTE
FPS
FEET PER SECOND
FSD
FIRE/SMOKE DAMPER
G
GAS
GRID
GRILLES, REGISTERS, AND
DIFFUSERS
GWB
GYPSUM WALLBOARD
HORIZ
HORIZONTAL
HP
HORSEPOWER, HEAT PUMP
HRU
HEAT RECOVERY UNIT
HVAC
HEATING, VENTILATING, AND AIR
CONDITIONING
HVU
HEATING AND VENTILATION UNIT
HWR
HIGH WALL RETURN, HOT WATER
RETURN
HWS
HIGH WALL SUPPLY, HOT WATER
SUPPLY
HX
HEAT EXCHANGER
ID
INDIRECT DRAIN, INSIDE DIAMETER
IN
INCH
KW
KILOWATT
L
LONG, LENGTH
LB
POUND
LWR
LOW WALL RETURN
LWS
LOW WALL SUPPLY
MBH
THOUSAND BTU PER HOUR
MECH
MECHANICAL
MCA
MINIMUM CIRCUIT AMPACITY
MOCP
MAXIMUM OVER CURRENT
PROTECTION
MTD
MOUNTED
OSA
OUTDOOR AIR
OBD
OPPOSED BLADE DAMPER
OD
OUTSIDE DIMENSION OR DIAMETER
OPNG
OPENING
P
PUMP
PD
PRESSURE DROP
POC
POINT OF CONNECTION
PRV
PRESSURE REDUCING VALVE
PSIG
POUNDS PER SQUARE INCH GAUGE
RA
RETURN AIR
REF
REFERENCE
RF
RELIEF FAN
RG
RETURN GRILLE
RPM
REVOLUTIONS PER MINUTE
SA
SUPPLY AIR
SCH
SCHEDULE
SF
SUPPLY FAN, SQUARE FOOT
SENS
SENSIBLE
SG
SUPPLY GRILLE
SMACNA
SHEET METAL AND AIR
CONDITIONING CONTRACTORS
NATIONAL
ASSOCIATION
SO
SCREENED OPENING
SP
STATIC PRESSURE
SS
STAINLESS STEEL, SANITARY
SEWER
SQ
SQUARE
TG
TRANSFER GRILLE
TYP
TYPICAL
UH
UNIT HEATER
UON
UNLESS OTHERWISE NOTED
V
VENT
VENT
VENTILATION, VENTILATOR
VTR
VENT THRU ROOF
W
WASTE, WATT, WIDE
WB WET BULB (TEMPERATURE)
EQUIPMENT
EF-1 TYPICAL EQUIPMENT DESIGNATION
(EXHAUST FAN SHOWN)
DSD DUCT SMOKE DETECTOR
O
ROOM THERMOSTAT OR
TEMPERATURE TRANSMITTER
O
ROOM HUMIDISTAT OR HUMIDITY
TRANSMITTER
co
CARBON MONOXIDE SENSOR
s�
SMOKE DETECTOR
TERMINALS
CD-12x12 CD-1*-DIFFUSER/GRILLE
TYPE, AND
OR
NUMBER OR SIZE
400 400DESIGN
CFM (WHERE APPLICABLE)
CEILING DIFFUSER (FLOW ARROWS
X
SHOWN FOR NON SYMMETRICAL
AIRFLOW)
CEILING RETURN/EXHAUST GRILLE
LINEAR DIFFUSER, CEILING OR WALL
MOUNTED (FLOW ARROWS SHOWN
y y
FOR NON SYMMETRICAL AIRFLOW)
WALL SUPPLY GRILLE (SG)
FAV_
WALL RETURN/EXHAUST GRILLE
(RG, EG)
TRANSFER GRILLE (TG), DUCT
CONNECTED, WALL MOUNTED W/
50
OPTIONAL CFM SHOWN
TRANSFER GRILLE, CEILING
MOUNTED WITH FULL-SIZED LINED
DUCT CONNECTION
GENERAL
ARCHITECTURAL BACKGROUND
(THIN LINE)
NEW MECHANICAL WORK
(HEAVY LINE)
- -
MATCHLINE OR PROPERTY LINE
SECTION INDENTIFICATION
(DETAIL SIMILAR)
INDICATES DIRECTION OF CUTTING
PLANE
A
LETTER INDICATES SECTION
M-3
M-3
(N0. INDICATES DETAIL)
SHEET # WHERE SECTION IS DRAWN
SHEET # WHERE SECTION IS TAKEN
DUCTWORK
DUCT (1ST FIGURE = SIDE SHOWN,
18x12
2ND FIGURE = SIDE NOT SHOWN)
UP DOWN
DUCT SECTION, POSITIVE PRESSURE
UP DOWN
DUCT SECTION, NEGATIVE
PRESSURE
UP DOWN
ROUND DUCT SECTION
UP UP UP
4 A X
DUCT PENETRATION THRU FLOOR
OR ROOF
FSD
=FSD
FIRE/SMOKE DAMPER
HORIZ DUCT, - * = VERT DUCT),
2-HR RATED, UON
VOLUME DAMPER
FD
�FD
FIRE DAMPER (--� = HORIZ
DUCT, --♦ = VERT DUCT), 2-HR
RATED, UON
90° ELBOW, R/D OR R/W=1.5
SQUARE CORNER ELBOW WITH
TURNING VANES
90` TAKE -OFF OR TEE
90` CONICAL TAKE -OFF
45` LATERAL TAKE -OFF
TRANSITION OR REDUCER (FOT =
FLAT ON TOP, FOB = FLAT ON
BOTTOM)
WYE FITTING
90° RECTANGULAR TAKE -OFF WITH
45° TAPER
90° DIVERGING RECTANGULAR TEE,
,{ EITHER RADIUS OR TURNING VANES
1111111111111111111111111110 FLEXIBLE DUCT
0 ROUND DUCT INDICATOR
GENERAL NOTES
GENERAL NOTES - MECHANICAL
1. REFERENCE TO RELATED WORK: "REF" INDICATIONS DENOTE
WORK COVERED ELSEWHERE (ARCHITECTURAL, STRUCTURAL,
CIVIL, ELECTRICAL, LANDSCAPE, OR KITCHEN), OR ITEM BASED
ON A SPECIFIC MANUFACTURER'S DIMENSIONS (VERIFY).
2. ELECTRICAL CHARACTERISTICS: REFER TO ELECTRICAL
DRAWINGS FOR ELECTRICAL CHARACTERISTICS (VOLTAGES, ETC.)
OF MECHANICAL EQUIPMENT, UNLESS OTHERWISE INDICATED.
3. CODES: COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM
SHALL BE PER THE APPLICABLE BUILDING, MECHANICAL, ENERGY,
PLUMBING, FIRE, AND HEALTH CODES AND REGULATIONS AS ADOPTED
BY THE LOCAL AHJ.
4. PREPARE AND SUBMIT FOR REVIEW A SHOP DRAWING BASED ON
FINAL STRUCTURAL SHOP DRAWINGS FOR LOCATING AND ROUTING ALL
DUCTWORK, DAMPERS, EQUIPMENT, PIPING, ETC.
A. COORDINATE FLOOR AND BEAM PENETRATIONS WITH STRUCTURAL.
B. COORDINATE FINAL LOCATION AND ROUTING WITH CEILING,
LIGHTS, WALLS, FIRE SPRINKLER PIPING, AND OTHER TRADES WORK
C. INCLUDE ADDITIONAL OFFSETS, ELBOWS, ROUTING, EQUIVALENT
DUCT SIZING EXCHANGE, RELOCATING, ETC. AS REQUIRED FOR A
COMPLETE OPERATING MECHANICAL SYSTEM.
D. PROVIDE SHOP DRAWINGS AT NO ADDITIONAL COST TO THE
OWNER.
5. MECHANICAL CONTRACTOR SHALL LOCATE AND COORDINATE EXACT
LOCATION OF ALL MECHANICAL EQUIPMENT WITHIN THE STRUCTURE.
6. ACCESS DOORS: COORDINATE WITH ARCHITECT AND LOCATE ALL
ACCESS DOORS ON SHOP DRAWINGS PRIOR TO BEGINNING OF
CONSTRUCTION. ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE
FIRE RATED. VERIFY ACCESS DOOR LOCATIONS WITH GENERAL
CONTRACTOR PRIOR TO BIDDING.
7. RATED PENETRATION: DUCT PENETRATIONS THROUGH RATED
ENCLOSURES SHALL BE FIRE/SMOKE DAMPERED PER THE LATEST
EDITION OF THE UNDERWRITERS LABORATORIES(UL) FIRE RESISTANCE
WITH HOURLY RATINGS FOR THROUGH -PENETRATION FIRE STOPS
SYSTEM VOLUME #2, OR SHALL BE INSTALLED IN STRICT ACCORDANCE
WITH THE MANUFACTURER'S UL LISTINGS (3M OR EQUIVALENT).
DETERMINE REQUIREMENTS WITH GENERAL CONTRACTOR PRIOR TO BID.
8. EXHAUST OUTLETS/DRYER VENTS: SOURCE -SPECIFIC FANS SHALL
BE VENTED TO OUTDOORS WITH A MINIMUM 3' CLEARANCE BETWEEN
VENT OUTLETS AND BUILDING OPENINGS, AND 10' MINIMUM BETWEEN
VENT OUTLETS AND MECHANICAL AIR INTAKES.
9. SHAFT AND PLENUM CONNECTIONS: SEAL CONNECTIONS TO AIR
SHAFTS AIRTIGHT. PROVIDE AIRTIGHT SEAL AROUND
PENETRATIONS IN AIR PLENUMS.
10. LIGHT FIXTURE CLEARANCE: COORDINATE LOCATIONS OF
MECHANICAL WORK TO PROVIDE CLEARANCES OVER LIGHTING
FIXTURES FOR REMOVAL AND REPLACEMENT.
11. MOTORS: COMPLY WITH ENERGY CODE ENFORCED BY AHJ FOR
MINIMUM EFFICIENCIES UNDER FULL LOAD.
12. ACCESS CLEARANCES FOR MAINTENANCE AND REPLACEMENT:
VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT
ACCESS CLEARANCES CAN BE MET. COORDINATE LOCATIONS OF
MECHANICAL WORK AND WORK OF OTHER TRADES TO PROVIDE
ACCESS CLEARANCES FOR SERVICE AND MAINTENANCE.
COORDINATION REQUIREMENTS
1. DUCTWORK: LOCATE AND COORDINATE THE EXACT LOCATION OF
DUCTWORK WITH STRUCTURAL PLANS AND WITH THE GENERAL
CONTRACTOR PRIOR TO INSTALLATION OF ANY STRUCTURE OR
EQUIPMENT. COORDINATE WITH FRAMING CONTRACTOR TO ASSURE
JOIST SPACES LINE UP WHEN DUCTWORK MUST PASS THROUGH
DIFFERENT JOIST SPACES.
2. ADJUSTMENTS: ALL EQUIPMENT, MOTORS, FANS GAS BURNERS,
IGNITION DEVICES, DRIVES, ETC. SHALL BE ADJUSTED AND
BALANCED TO OPERATE AT SPECIFIED RATINGS AS REQUIRED FOR
THIS PROJECT SITE AND ACCOUNTING FOR ELEVATION ABOVE SEA
LEVEL.
3. APPROVALS: MECHANICAL AND PLUMBING EQUIPMENT SHALL BE
APPROVED FOR INSTALLATION IN THE PROJECT LOCATION AND SHALL
HAVE ALL CERTIFICATIONS AND RATINGS TO MEET ALL ENERGY,
POLLUTION, ENVIRONMENTAL, SEISMIC, ETC. CODES AND
REGULATIONS. THE CONTRACTOR SHALL COORDINATE WITH HIS
MANUFACTURE SUPPLIERS AND SHALL INCLUDE ALL COSTS REQUIRED
TO MEET THESE REQUIREMENTS IN HIS BID.
HVAC NOTES
1. ATTACHMENTS: AIR DISTRIBUTION OUTLETS AND LOUVERS SHALL
HAVE ALL REQUIRED ACCESSORIES AND ATTACHMENTS FOR A COMPLETE
CONNECTION TO THE SPECIFIC TYPE OF STRUCTURE THAT THEY ARE
BEING ATTACHED TO. THIS INCLUDES, BUT IS NOT LIMITED TO,
EXTERIOR BRICKS, GWB WALLS, GWB CEILING, ETC.
2. FIRE RATINGS: RATED FLOOR/CEILING JOINT SPACES HAVING
DUCTWORK INSIDE THEM SHALL BE FIRE/SMOKE PROTECTED TO
MAINTAIN THE 1-HOUR FLOOR/CEILING RATING PER LOCAL
JURISDICTIONS. EXHAUST DUCTWORK PENETRATING THE 1-HOUR
ROOF/CEILING OR FLOOR/CEILING ASSEMBLY SHALL HAVE ACCESSIBLE
CEILING FIRE DAMPERS. ALTERNATIVELY, THE EXHAUST DUCTWORK
SHALL BE ROUTED INSIDE A RATED SHAFT TO PROTECT THE
CEILING/ROOF RATING PER THE LOCAL JURISDICTIONS.
3. FIRESTOP: PIPE, DUCT, AND CONDUIT PENETRATIONS THROUGH
RATED ASSEMBLIES SHALL BE FIRE AND SMOKE STOPPED PER CODE.
4. DUCTWORK: DUCTWORK SHALL BE SMOOTH SHEET METAL (CLASS-1).
DUCTWORK THROUGH FIRE RATED STRUCTURE AND FLOOR SHALL BE
MIN. 26 GA. STEEL. MAXIMUM LENGTH OF FLEXIBLE DUCTS SHALL BE
5-0", UNLESS OTHERWISE NOTED ON DRAWINGS. DUCTWORK SIZES
SHOWN ARE INSIDE CLEAR DIMENSIONS.
ALL WORK SUBJECT
IN
5. DUCTWORK AND PIPING OUTSIDE OF MECHANICAL ROOMS S LL
BE CONCEALED. COORDINATE WITH THE GENERAL CONTRAC R COI
TO FUR -OUT AS REQUIRED.
6. VOLUME DAMPERS: PROVIDE AN ACCESSIBLE MANUAL VOL
DAMPER FOR EACH SUPPLY, RETURN, OSA, AND EXHAUST
OPENING, LOCATED AS FAR UPSTREAM AS POSSIBLE FROM THE
OPENING. PROVIDE A MANUAL VOLUME DAMPER FOR BRANCH
MAINS SERVING MORE THAN ONE OPENING. VOLUME DAMPERS
IN NON -ACCESSIBLE CEILINGS SHALL HAVE A CONTROL ARM
EXTENDED TO AN ACCESSIBLE LOCATION. PROVIDE "YOUNG"
REGULATOR OR EQUAL. EXACT LOCATION OF CONTROL DEVICES
VISIBLE IN FINISHED SPACES SHALL BE COORDINATED WITH
THE ARCHITECT.
7. SEISMIC: PROVIDE SEISMIC RESTRAINTS FOR MECHANICAL
EQUIPMENT, PIPING, AND DUCTWORK PER SMACNA AND LOCAL
REGULATIONS.
8. FILTER CLEARANCE: PROVIDE ADEQUATE CLEARANCE FOR
CHANGING AIR FILTERS
SHEET METAL NOTES
1. REFERENCE: SMACNA HVAC DUCT CONSTRUCTION STANDARDS,
METAL AND FLEXIBLE, CURRENT EDITION.
2. CLEARANCE: COORDINATE DUCTWORK WITH MISCELLANEOUS
OBSTRUCTIONS IN CEILING SPACE.
3. ROUND ELBOWS AND OFFSETS: FULL RADIUS (R/D = 1.5),
5-PIECE SEGMENTED OR STAMPED. REFER TO SMACNA HVACDCS
FIG 2-7, 3-3. DO NOT USE ANGLED OFFSET (TYPE 1).
MITERED OFFSET (TYPE 2) MAY BE USED UP TO 30 DEGREE
OFFSET ANGLE.
4. ROUND TEES AND LATERALS: CONICAL TEE PER SMACNA HVACDCS
FIG 3-5; DO NOT USE STRAIGHT TEE; DO NOT USE CONICAL
SADDLE TAP FOR EXPOSED DUCTWORK IN FINISHED SPACES. 90-
DEGREE TEE WITH OVAL TO ROUND TAP, LATERAL, AND 45-
DEGREE RECTANGULAR LEAD-IN PER SMACNA HVACDCS FIG 3-4.
5. RECTANGULAR ELBOWS AND OFFSETS: FULL RADIUS WHERE SPACE
PERMITS, R/W = 1.5; OTHERWISE USE SQUARE CORNER ELBOW
WITH TURNING VANES.
6. RECTANGULAR DIVIDED FLOW FITTINGS: USE GENERALLY,
EXCEPT BRANCHES TO TERMINALS; SMACNA HVACDCS FIG 2-5,
TYPES 1, 2, 4A, AND 4B. DO NOT USE TYPE 3.
7. TURNING VANES: H.E.P. MANUFACTURER OR APPROVED HIGH
EFFICIENCY PROFILE AIRFOIL TYPE FOR RECTANGULAR SQUARE
THROAT ELBOWS.
8. TAKEOFFS TO OPENINGS: CONICAL TYPE WITH VOLUME DAMPER
FOR ROUND DUCT BRANCHES PER SMACNA HVACDCS FIG 2-6,
MINIMUM INLET DIAMETER 2 INCHES LARGER THAN DUCT SIZE.
45 DEGREE ENTRY FITTING FOR RECTANGULAR DUCT BRANCHES
PER SMACNA HVACDCS FIG 2-6.
9. FLEXIBLE CONNECTIONS: PROVIDE AT EACH DUCT CONNECTION
TO FANS, PACKAGED HVAC EQUIPMENT, EXTERNALLY ISOLATED
AIR HANDLING UNITS, FAN COIL UNITS, AND SIMILAR
EQUIPMENT. EXCEPTION: EQUIPMENT IN CORRIDOR CEILING
SPACES WHERE FIRE RATING IS REQUIRED.
INSULATION/ LINING NOTES
1. ENERGY CODE: AS A MINIMUM, COMPLY WITH THICKNESSES AND
TYPES LISTED IN ENERGY CODE ENFORCED BY AHJ.
2. EXTENT OF INTERNAL DUCT LINING:
A. GRILLE AND DIFFUSER BOXES AND BOOTS.
B. TRANSFER DUCTS.
3. EXTENT OF EXTERNAL DUCT INSULATION:
A. SUPPLY AND RETURN AIR IN UNCONDITIONED SPACES,
MECHANICAL ROOMS, ELECTRICAL ROOMS, AND EQUIPMENT
ROOMS NOT SPECIFIED TO BE INTERNALLY LINED.
B. SUPPLY AIR IN CONCEALED LOCATIONS NOT
SPECIFIED TO BE INTERNALLY LINED.
C. OUTDOOR AIR INTAKE.
D. EXHAUST DUCT IN UNCONDITIONED SPACES.
4. MISCELLANEOUS DUCT FITTINGS (CONICAL TAKEOFFS, ETC.):
WRAP WITH INSULATION FOR CONDENSATION CONTROL.
PIPING NOTES
1. DISASSEMBLY PROVISIONS: PROVIDE UNIONS OR FLANGES AT
PIPING CONNECTIONS TO EQUIPMENT, COILS, TRAPS, CONTROL
VALVES, AND OTHER COMPONENTS TO ALLOW DISASSEMBLY FOR
MAINTENANCE.
2. REDUCERS: PROVIDE AS REQUIRED FROM LINE PIPE SIZE TO
EQUIPMENT, TRAP, COIL, AND CONTROL VALVE CONNECTION
SIZES.
3. OFFSETS: PROVIDE FOR BRANCH LINES TO EQUIPMENT.
4. DIELECTRIC UNIONS: PROVIDE AT CONNECTIONS OF DISSIMILAR
PIPE.
DRAWINGS ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION,
TYPE, LAYOUT, AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL
NOT BE SCALED FOR EXACT MEASUREMENT. REFER TO ARCHITECTURAL
DRAWINGS FOR DIMENSIONS. REFER TO MANUFACTURER'S STANDARD
INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND
INSTALLATION REQUIREMENTS. PROVIDE DUCTWORK, CONNECTIONS,
ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY FOR A COMPLETE
SYSTEM.
TO FIELD
IPECTION FOR
E COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
APPROVED BY PLANNING
CPMA/�IS,W�
Aug 02 2024
Noise generated by mechanical
equipment must meet the
standards in ECC 5.30
City Of Edmonds
Building Department
Work MECHANICAL- RTU
Address 50 PINE ST UNIT 201
Owner SHERRARD
Approved Date 08/06/2024
Building Official Er &
Permit Number BLD2024-1004
PROJECT
LOCATION
APPUCABLE CODES
THESE DRAWINGS ARE BASED ON THE FOLLOWING CODES:
-2021 INTERNATIONAL BUILDING CODE (WITH WASHINGTON STATE AMENDMENTS)
-2021 INTERNATIONAL MECHANICAL CODE (WITH WASHINGTON STATE AMENDMENTS)
-2021 WASHINGTON STATE ENERGY CODE
DRAW G DEX
DWG
DESCRIPTION
MO.0
LEGEND, NOTES & INDEX
MO.1
SCHEDULES / DETAILS
M1.0
HVAC PLANS
P S � I At� � F
r
*FC►iAN%GP
Gasline Mechanical Inc.
9926 Elliot Rd.
Snohomish WA 98296
.';��cF Asy��c• ;
z:
1-10o �sr'ER�° �oov
��Op TONAL ENGp �o
i" - I7--)-Lk
�000000
EXPIRES: 10/25/24
ISSUE:
0
RECEIVED
Aug 02 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
SHEET NO.
LEGEND, NOTES,
& INDEX
M 0 0 0
PROJECT NO.
COPYRIGHT 2024, PINEHURST ENGINEERING / GASLINE MECHANICAL
7/ 17/24
PERMIT SET
SPLIT SYSTEM
HEAT
PUMP SCHEDULE
INDOOR UNIT
EQUIP NO.
SERVICE
MOUNTING/
DISCHARGE
FAN
ELECTRICAL
BASIS OF DESIGN (1)(2)(3)
CONNECTED
OUTDOOR
UNIT
AIRFLOW,
CFM
MOTOR
HP
VOLTAGE
MOCP
IHP-201
A
UNIT
201
HIGH
WALL
335
FHP
208V/1 P
15
BOSCH
BMS500-AA0009-1
AHWXC
OHP-201
IHP-201
B
UNIT
201
HIGH
WALL
523
FHP
208V/1 P
15
BOSCH
BMS500-AAUO18-1
AHWXC
OHP-201
IHP-422A
UNIT
422
HIGH
WALL
335
FHP
208V/1 P
15
BOSCH
BMS500-AA0009-1
AHWXC
OHP-422
IHP-422B
UNIT
422
HIGH
WALL
523
FHP
208V/1 P
15
BOSCH
BMS500-AAU018-1
AHWXC
OHP-422
IHP-423A
UNIT
423
HIGH
WALL
335
FHP
208V/1 P
15
BOSCH
BMS500-AA0009-1
AHWXC
OHP-423
IHP-423B
UNIT
423
HIGH
WALL
523
FHP
208V/1 P
15
BOSCH
BMS500-AAU018-1
AHWXC
OHP-4231
IHP-515A
UNIT
515
HIGH
WALL
335
FHP
208V/1P
15
BOSCH
BMS500-AA0009-1AHWXC
OHP-515
IHP-515B
UNIT
515
HIGH
WALL
523
FHP
208V/1P
15
BOSCH
BMS500-AAU018-1AHWXC
OHP-515
IHP-517A
UNIT
517
HIGH
WALL
335
FHP
208V/1P
15
BOSCH
BMS500-AA0009-1AHWXC
OHP-517
IHP-517B
UNIT
517
HIGH
WALL
523
FHP
208V/1P
15
BOSCH
BMS500-AAU018-1AHWXC
OHP-517
NOTES: (1) INSTALL UNITS AS SHOWN AND AS RECOMMENDED BY THE MANUFACTURER IN COMPLIANCE WITH LOCAL CODES.
(2) PROVIDE CONDENSATE PUMP IF REQUIRED.
SPLIT SYSTEM HEAT PUMP SCHEDULE - OUTDOOR UNIT
EQUIP N0.
SERVICE
CAPACITY,
TOTAL COOLING
SEER
TOTAL HEATING
HSPF
REFRIGERANT
ELECTRICAL
WEIGHT, LBS
SOUND RATING
BASIS OF DESIGN (1)(2)(3)(4)
CONNECTED
VOLTAGE
MOCP
TONS
CAPACITY, BTUH
CAPACITY, BTUH
CHARGE, LBS
(dB)
IHP
OHP-201
UNIT 201
2.5
30,776
25.5
13,000
12.3
5.73
208V/1 P
30
140
61
BOSCH
IHP-21 OA/B
BMS500-AAM027-1 CSXRC
OHP-422
UNIT 422
2.5
30,776
25.5
13,000
12.3
5.73
208V/1 P
30
140
61
BOSCH
IHP-422A/B
BMS500-AAMO27-1 CSXRC
OHP-423
UNIT 423
2.5
30,776
25.5
13,000
12.3
5.73
208V/1 P
30
140
61
BOSCH
IHP-423A/B
BMS500-AAM027-1 CSXRC
OHP-515
UNIT 515
2.5
30,776
25.5
13,000
12.3
5.73
208V/1P
30
140
61
BOSCH
IHP-515A/B
BMS500-AAM027-1 CSXRC
OHP-517
UNIT 517
2.5
30,776
25.5
13,000
12.3
5.73
208V/1P
30
140
61
BOSCH
IHP-517A/B
BMS500-AAM027-1 CSXRC
NOTES: (1) ARI LISTED WITH ALL STANDARD FEATURES, INSTALLATION ACCESSORIES AND COMPRESSOR SHORT CYCLING PROTECTION. FILTER DRIER, REFRIGERANT LINE FILTER, LIQUID SOLENOID
VALVE, AND SAFETY PRESSURE SWITCHES. INSTALL REFRIGERANT TUBING AND LENGTH IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION.
(2) PROVIDE ALL REQUIRED ACCESSORIES FOR LOW -AMBIENT AND LONG -LINE APPLICATIONS.
(3) ROUTING OF REFRIGERANT LINES FROM INDOOR TO OUTDOOR UNITS NOT SHOWN ON PLANS. CONTRACTOR TO FIELD COORDINATE ROUTING.
(4) REFRIGERANT SHALL BE R-410A.
ISOLATION SPRING (TYP)
SOLDERED CURB CAP (TYP)-
OHP MOUNTING W
DETAIL
SCALE: NONE
OHP UNIT
ROOFTOP CHASE
SIZE PER PLANS
8" ROOF CURB PEA
ROOFING AND FLASI
INSTALLED PER MAf
REQUIREMENTS
PER PLANS
CHASE PENETRATION THROUGH ROOF
DETAIL
SCALE: NONE
nnr A I/ TOP FOR
GE
JOUS SOLDERED
-0 DUCT FOR
-TIGHT
'UCTION
11N. CURB CAP
P 5 N
v
�tcC#1AN%C'
Gasline Mechanical Inc.
9926 Elliot Rd.
Snohomish WA 98296
v0,o oN000No��o 7-a-��
EXPIRES: 1 0/25/24
ISSUE
C
C7
Q
H
a
RECEIVED
Aug 02 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
SHEET NO.
SCHEDULES
DETAILS
Moe 1
PROJECT NO.
7/ 17/24
PERMIT SET
COPYRIGHT 2024, PINEHURST ENGINEERING / GASLINE MECHANICAL
WEST ROOF HVAC
SCALE: 1 /8" = 1'-0" N
i
I
I
I
I
Ee
1
520' TO
SHEETMETAL COVER
FOR REFRIGERANT AND
ELECTRICAL LINES
(TYP)
dog
EAST ROOF HVAC
SCALE: 1 /8" = 1'-0"
I I
F
LL
-- L
4 (i0� dog
UNITS 515 /51 7 HVAC UNITS 42 2 /42 3 HVAC
SCALE: 1 /8" = 1'-0" I SCALE: 1 /8" = 1'-0"
)HP-201
750' TO
IPERTY LINE—
<55 dBA)
/
/
/
/
/
N�
I
ac
I
I
I
I
I
�F
T --J
0
LINE SE
TO ROOF
I
UNIT 201 HVAC
SCALE: 1 /8" = 1'-0" N
4koc#1AN%GP
Gasline Mechanical Inc.
9926 Elliot Rd.
Snohomish WA 98296
v0�o oN000No��o 7-a—��
EXPIRES: 1 0/25/24
RECEIVED
Aug 02 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
SHEET NO.
UNIT PLANS
M 1 00
PROJECT NO.
7/ 17/24
PERMIT SET
COPYRIGHT 2024, PINEHURST ENGINEERING / GASLINE MECHANICAL