APPROVED BY PLANNING
I
Sep 03 2024
Noise generated by mechanical
equipment must meet the
standards in ECC 5.30
GENERAL CONSTRUCTION NOTES
1, The General Contractor shall provide building penetrations, roofing, and other
construction needs f or installation of system equipment.
2, The General Contractor shall be responsible for maintaining structural integrity and
provide required structural supports as required City of Edmonds.
3, The General Contractor shall be responsible f or other trades unless otherwise stated
by the conditions of the general contract with the project owner.
EXHAUST SYSTEM NOTES
1, The exhaust/make-up air systems are to meet requirements of the International Mechanical Code,
and NFPA-96, The Type I exhaust ductwork to be constructed of f ully welded 16 gauge steel.
2. Exhaust must be a minimum of 10'-0" from any air intake, adjacent building, or adjoining property.
3. Exhaust and make-up air systems must be electrically interconnected to be operated
simultaneously by a single on/of f switch,
ELECTRICAL NOTES
1, The electrical contractor shall provide and install interconnecting f field wiring between the
hood equipment control switches, and exhaust / make-up air system equipment contactors.
2. The electrical contractor shall install exhaust f an and make-up air system motor relays
and disconnect switches,
3. The electrical contractor shall verif y proper f an motor rotation,
IMC 2018 SECTI❑N 50711 ❑PERATI❑N, (PARTIAL)
THE EXHAUST FAN SERVING A TYPE I HOOD SHALL HAVE AUT❑MATIC CONTROLS THAT
WILL ACTIVATE THE FAN WHEN ANY APPLIANCE THAT REQUIRES SUCH TYPE I HOOD
IS TURNED ON, OR A MEANS OF INTERL❑CK SHALL BE PR❑VIDED THAT WILL PREVENT
❑PERATI❑N OF SUCH APPLIANCES WHEN THE IS NOT TURNED ON..
TYPE I EXHAUST AIR DUCTWORK TO BE
FULLY WELDED 16 GAUGE STEEL
DUCTWORK TO BE C❑NTINU❑US INTERNAL
OR EXTERNAL LIQUID -TIGHT WELDED
SMOOTH, ACCESSIBLE FOR INSPECTI❑N,
AND WITH❑UT GREASE TRAPS
MAKE-UP AIR DUCTWORK TO BE
FULLY SEALED 22 GAUGE STEEL
MAKE-UP AIR DUCTWORK TO BE INSULATED
FireMaster® FastWrap® XL
Grease and HVAC Duct Enclosure System
1 or 2 Hour Shaft Alternative / Zero Clearance to Combustibles
LEGEND TWO LAYER INSTALLATION (Grease Duct per ASTM E2336)
1
Two Layers of XL Insulation for ASTM E2336 and CAN/ULC S144 Grease Duct Enclosures
One Layer of XL Insulation for 2-Hour Air Ventilation Duct Enclosures
2
Steel banding minimum 1/2" (13) wide by 0.015" (0.4) thick.
3
Tight butt joints (no overlap) at perimeter and longitudinal joints, both layers for grease ducts
4
Min. 3" (75) overlap on perimeter and between adjacent blankets
5
Optional 6" XL collar
6
Hangers - size dependent weight of assembly (see datasheet Section G)
7
Trapeze Supports - size dependent on weight of assembly (see datasheet Section G)
8
Steel Rectangular or Round Duct (size, gage and construction dependent per Listed Design)
2 1 1/2" (38) 1 3
Butt Joint Typical
ONE HOUR FIRE
RATED DUCT WRAP Not roScale
f
223,4'
/ � I
______________=====L=====_______-_
1 40,'
, r
41
40'
135.2',+
/./1000
� f
40,
\ \`
243YaY�Ac/
I
I
I
I
� 62,1
\ 135,2' /X#0
135,2'
V
o�
SW
r
f
.
s�
A/
ao'�.q
3
�P
Aquarium Co-op
�
-5
Tropical fish store
P
v
N
Firdale Village911- r
"Shopping
Plaza - -
�24301P1t—
•
a
s
Brackett Apartments
J
W
—, —
7> LJ r
A.
t�
L rn
NW 203rd St NW 203rd St
VICINITY MAP
NORTH
Not to Scale
N 203rd St
_- 29,6'
107,5'
n155,5'
I i
I
� I
72,5'
41,1'
SITE PLAN
NORTH
Scale I" = 3 5'-0"
Parcel Number 00449900000100 Property9617 FIRDALE AVE, EDMONDS, WA 98020-6519
General Information
Section 36 Township 27 Range 03 Quarter SE - FORSHEES FIRDALE VILLAGE BLK 000 D-00 - COMB FOR TAX PURP ONLY -
LOT 1 PLUS PTN VAC CUL-DE-SAC TGW LOTS 2-3 PLUS ADJ PTN VAC CUL-DE-SAC LESS PIN WHNFORSHEE FIRDALE
VII LAGE 5 ALSO LESS TH PTN LOT 3DAF - BEG AT NE COR OF S1/2 N1/2 OF SW 1/4 SE 1/4 TH S01 *42 29W ALG E LN OF SD
Property Description
SW 1/4 SE1/4 51OFT TH N88*26 50W 75FT TPBTH CONT N88*26 50W 104.06FT THS72*21 54E 108.30FT TH NO1*33 l0E 30FT
TPB TGW LOT 4 PLUS ADJ PTN VAC CUL-DE-SAC LESS PTN WHN FORSHEE FIRDALE VILLAGE 5 TGW LOT 5 PLUS PTN
VAC CUL-DE-SAC & LESS PTN PROP PLAT FORSHEES FIRDALEVILLAGE NO 5 TGW LOT 12 TGW LOT 13 & NWLY 8FT
LOT 14 TGW SELY 52FT LOT 14
Property Category
Land and Improvements
Status
Active, Host Other Property, Locally Assessed
Tax Code Area
100216
SHEET INDEX
SHEET 1 VICINITY MAP, SITE PLAN, LEGAL INF❑RMATI❑N & NOTES
SHEET 2 PLAN VIEW, ROOF PLAN
SHEET 3 SECTI❑N, EQUIPMENT SCHEDULE
SHEET 4 ELEVATI❑N, NOTES
SHEET 5 ACCUREX EQUIPMENT INF❑RMATI❑N
SHEET 6 ACCUREX AIRE EQUIPMENT INF❑RMATI❑N
REVISIONS:
BLD2023-1623
RESUB
Jul 15 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Q) o
M N
C: O
00
> M
z Q
Q Q
fu
L �
z ILL
CD E
0 73
W w0
a_
O
a
a
a�
0
w�
� I
4-) ICJ
C/D _
O C�2
� N
CO
O
o 4
M a
DRAWN BY: DOUG WALTER
DATE: 12/ 15/23
TI TLE:
COMMERCIAL KITCHEN
EXHAUST SYSTEM
SHEET: