Loading...
APPROVED PLN RESUB1 BLD2023-1623+Site_Plan+7.15.2024_3.29.14_PM+4378830z Q U Z Q C) LEI 71 LEI Q U LEI z LL 0 z 0 U) ry Lv I- 0 _ ry 0 LL z Q z 0 LEI LLI m I- 0 z Q w W V) _ z 0 z 0 cn Q Q 0 0 W Ld U) Lv I- c J Q APPROVED BY PLANNING I Sep 03 2024 Noise generated by mechanical equipment must meet the standards in ECC 5.30 GENERAL CONSTRUCTION NOTES 1, The General Contractor shall provide building penetrations, roofing, and other construction needs f or installation of system equipment. 2, The General Contractor shall be responsible for maintaining structural integrity and provide required structural supports as required City of Edmonds. 3, The General Contractor shall be responsible f or other trades unless otherwise stated by the conditions of the general contract with the project owner. EXHAUST SYSTEM NOTES 1, The exhaust/make-up air systems are to meet requirements of the International Mechanical Code, and NFPA-96, The Type I exhaust ductwork to be constructed of f ully welded 16 gauge steel. 2. Exhaust must be a minimum of 10'-0" from any air intake, adjacent building, or adjoining property. 3. Exhaust and make-up air systems must be electrically interconnected to be operated simultaneously by a single on/of f switch, ELECTRICAL NOTES 1, The electrical contractor shall provide and install interconnecting f field wiring between the hood equipment control switches, and exhaust / make-up air system equipment contactors. 2. The electrical contractor shall install exhaust f an and make-up air system motor relays and disconnect switches, 3. The electrical contractor shall verif y proper f an motor rotation, IMC 2018 SECTI❑N 50711 ❑PERATI❑N, (PARTIAL) THE EXHAUST FAN SERVING A TYPE I HOOD SHALL HAVE AUT❑MATIC CONTROLS THAT WILL ACTIVATE THE FAN WHEN ANY APPLIANCE THAT REQUIRES SUCH TYPE I HOOD IS TURNED ON, OR A MEANS OF INTERL❑CK SHALL BE PR❑VIDED THAT WILL PREVENT ❑PERATI❑N OF SUCH APPLIANCES WHEN THE IS NOT TURNED ON.. TYPE I EXHAUST AIR DUCTWORK TO BE FULLY WELDED 16 GAUGE STEEL DUCTWORK TO BE C❑NTINU❑US INTERNAL OR EXTERNAL LIQUID -TIGHT WELDED SMOOTH, ACCESSIBLE FOR INSPECTI❑N, AND WITH❑UT GREASE TRAPS MAKE-UP AIR DUCTWORK TO BE FULLY SEALED 22 GAUGE STEEL MAKE-UP AIR DUCTWORK TO BE INSULATED FireMaster® FastWrap® XL Grease and HVAC Duct Enclosure System 1 or 2 Hour Shaft Alternative / Zero Clearance to Combustibles LEGEND TWO LAYER INSTALLATION (Grease Duct per ASTM E2336) 1 Two Layers of XL Insulation for ASTM E2336 and CAN/ULC S144 Grease Duct Enclosures One Layer of XL Insulation for 2-Hour Air Ventilation Duct Enclosures 2 Steel banding minimum 1/2" (13) wide by 0.015" (0.4) thick. 3 Tight butt joints (no overlap) at perimeter and longitudinal joints, both layers for grease ducts 4 Min. 3" (75) overlap on perimeter and between adjacent blankets 5 Optional 6" XL collar 6 Hangers - size dependent weight of assembly (see datasheet Section G) 7 Trapeze Supports - size dependent on weight of assembly (see datasheet Section G) 8 Steel Rectangular or Round Duct (size, gage and construction dependent per Listed Design) 2 1 1/2" (38) 1 3 Butt Joint Typical ONE HOUR FIRE RATED DUCT WRAP Not roScale f 223,4' / � I ______________=====L=====_______-_ 1 40,' , r 41 40' 135.2',+ /./1000 � f 40, \ \` 243YaY�Ac/ I I I I � 62,1 \ 135,2' /X#0 135,2' V o� SW r f . s� A/ ao'�.q 3 �P Aquarium Co-op � -5 Tropical fish store P v N Firdale Village911- r "Shopping Plaza - - �24301P1t— • a s Brackett Apartments J W —, — 7> LJ r A. t� L rn NW 203rd St NW 203rd St VICINITY MAP NORTH Not to Scale N 203rd St _- 29,6' 107,5' n155,5' I i I � I 72,5' 41,1' SITE PLAN NORTH Scale I" = 3 5'-0" Parcel Number 00449900000100 Property9617 FIRDALE AVE, EDMONDS, WA 98020-6519 General Information Section 36 Township 27 Range 03 Quarter SE - FORSHEES FIRDALE VILLAGE BLK 000 D-00 - COMB FOR TAX PURP ONLY - LOT 1 PLUS PTN VAC CUL-DE-SAC TGW LOTS 2-3 PLUS ADJ PTN VAC CUL-DE-SAC LESS PIN WHNFORSHEE FIRDALE VII LAGE 5 ALSO LESS TH PTN LOT 3DAF - BEG AT NE COR OF S1/2 N1/2 OF SW 1/4 SE 1/4 TH S01 *42 29W ALG E LN OF SD Property Description SW 1/4 SE1/4 51OFT TH N88*26 50W 75FT TPBTH CONT N88*26 50W 104.06FT THS72*21 54E 108.30FT TH NO1*33 l0E 30FT TPB TGW LOT 4 PLUS ADJ PTN VAC CUL-DE-SAC LESS PTN WHN FORSHEE FIRDALE VILLAGE 5 TGW LOT 5 PLUS PTN VAC CUL-DE-SAC & LESS PTN PROP PLAT FORSHEES FIRDALEVILLAGE NO 5 TGW LOT 12 TGW LOT 13 & NWLY 8FT LOT 14 TGW SELY 52FT LOT 14 Property Category Land and Improvements Status Active, Host Other Property, Locally Assessed Tax Code Area 100216 SHEET INDEX SHEET 1 VICINITY MAP, SITE PLAN, LEGAL INF❑RMATI❑N & NOTES SHEET 2 PLAN VIEW, ROOF PLAN SHEET 3 SECTI❑N, EQUIPMENT SCHEDULE SHEET 4 ELEVATI❑N, NOTES SHEET 5 ACCUREX EQUIPMENT INF❑RMATI❑N SHEET 6 ACCUREX AIRE EQUIPMENT INF❑RMATI❑N REVISIONS: BLD2023-1623 RESUB Jul 15 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Q) o M N C: O 00 > M z Q Q Q fu L � z ILL CD E 0 73 W w0 a_ O a a a� 0 w� � I 4-) ICJ C/D _ O C�2 � N CO O o 4 M a DRAWN BY: DOUG WALTER DATE: 12/ 15/23 TI TLE: COMMERCIAL KITCHEN EXHAUST SYSTEM SHEET: M-1