APPROVED PLN BLD FIR RESUB1 BLD2024-0067+Mechanical_Plan+4.19.2024_11.54.18_AM+4207635z J Q U Z Q C) LEI 71 LEI J Q U LEI z 0 z 0 U) ry Ld 0 ry 0 LL z Q z 0 LEI LLI m I- 0 z Q w Ld V) z 0 z 0 Q Q 0 0 Ld Ld U) W 0 it J J Q 04-24-2024 PLAN REVIEW NOTES APPROVED WITH CONDITION. 1. SEPARATE PERMIT REQUIRED FOR SUPPRESSION SYSTEM. DFM BURT GENERAL CONSTRUCTION NOTES Approved DFM akyis Burt South County Fire Date: 04/24/2024 1, The General Contractor shall provide building penetrations, roofing, and other construction needs f or installation of system equipment. 2, The General Contractor shall be responsible for maintaining structural integrity and provide required structural supports as required City of Edmonds. 3, The General Contractor shall be responsible f or other trades unless otherwise stated by the conditions of the general contract with the project owner. EXHAUST SYSTEM NOTES 1, The exhaust/make-up air systems are to meet requirements of the International Mechanical Code, and NFPA-96, The Type I exhaust ductwork to be constructed of f ully welded 16 gauge steel. 2. Exhaust must be a minimum of 10'-0" from any air intake, adjacent building, or adjoining property. 3. Exhaust and make-up air systems must be electrically interconnected to be operated simultaneously by a single on/of f switch, ELECTRICAL NOTES 1, The electrical contractor shall provide and install interconnecting f field wiring between the hood equipment control switches, and exhaust / make-up air system equipment contactors. 2. The electrical contractor shall install exhaust f an and make-up air system motor relays and disconnect switches, 3. The electrical contractor shall verif y proper f an motor rotation, IMC 2018 SECTI❑N 50711 ❑PERATI❑N, (PARTIAL) THE EXHAUST FAN SERVING A TYPE I HOOD SHALL HAVE AUT❑MATIC CONTROLS THAT WILL ACTIVATE THE FAN WHEN ANY APPLIANCE THAT REQUIRES SUCH TYPE I HOOD IS TURNED ON, OR A MEANS OF INTERL❑CK SHALL BE PR❑VIDED THAT WILL PREVENT ❑PERATI❑N OF SUCH APPLIANCES WHEN THE IS NOT TURNED ON.. TYPE I EXHAUST AIR DUCTWORK TO BE FULLY WELDED 16 GAUGE STEEL DUCTWORK TO BE C❑NTINU❑US INTERNAL OR EXTERNAL LIQUID -TIGHT WELDED SMOOTH, ACCESSIBLE FOR INSPECTI❑N, AND WITH❑UT GREASE TRAPS MAKE-UP AIR DUCTWORK TO BE FULLY SEALED 22 GAUGE STEEL MAKE-UP AIR DUCTWORK TO BE INSULATED FireMaster® FastWrap® XL Grease and HVAC Duct Enclosure System 1 or 2 Hour Shaft Alternative / Zero Clearance to Combustibles APPROVED LANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE 223,4' � I ______________=====L=====_______-_ 40,1' 4 \ , f \ ' 135.2',+ /./1000 \ f 40, \ \` N. \ \ \ 243 I\ I I I I I I I f � 62,1 \ 135,2' /X#0 135,2' f� <� � 154,5,E Equipment platforms and access paths will a!re not part � of the mechanical permit and w,� ill be constructed under the TI permit. Applicable access shall be completed prior r� to final approval o the Mechanical permit. LEGEND TWO LAYER INSTALLATION (Grease Duct per ASTM E2336) 1 Two Layers of XL Insulation for ASTM E2336 and CAN/ULC S144 Grease Duct Enclosures One Layer of XL Insulation for 2-Hour Air Ventilation Duct Enclosures 2 Steel banding minimum 1/2" (13) wide by 0.015" (0.4) thick. 3 Tight butt joints (no overlap) at perimeter and longitudinal joints, both layers for grease ducts 4 Min. 3" (75) overlap on perimeter and between adjacent blankets 5 Optional 6" XL collar 6 Hangers - size dependent weight of assembly (see datasheet Section G) 7 Trapeze Supports - size dependent on weight of assembly (see datasheet Section G) 8 Steel Rectangular or Round Duct (size, gage and construction dependent per Listed Design) 2 1 1/2" (38) 1 3 Butt Joint Typical \3 ONE HOUR FIRE RATED DUCT WRAP Not roScale City Of Edmonds Building Department ------------ Work TYPE 1 HOOD Address 9601 FIRDALE AVE - ----- --- --- --- --- --- ------------ Owner TR8INIS PANTRY Approved Date 04/30/2024 Official ------------------------ Permit Number BLD2024-0067 o� SW r f . s� A/ ao'�.q 3 �P Aquarium Co-op 9 U) -5 Tro ical fish store P -1N Firdale Village911- r "Shopping Plaza - - �24301P1t5� • a s Brackett Apartments J W > LJ P 7-1 r ❑ L [ L t� L rn z NW 203rd St NW 203rd StAm N 203rd St VICINITY MAP NORTH Not to Scale _- 29,6' -v 107,5' n155,5' I i I I 72,5' SITE PLAN NORTH Scale I" = 3 5'-0" Parcel Number 00449900000100 Property9617 FIRDALE AVE, EDMONDS, WA 98020-6519 General Information Section 36 Township 27 Range 03 Quarter SE - FORSHEES FIRDALE VILLAGE BLK 000 D-00 - COMB FOR TAX PURP ONLY - LOT 1 PLUS PTN VAC CUL-DE-SAC TGW LOTS 2-3 PLUS ADJ PTN VAC CUL-DE-SAC LESS PIN WHNFORSHEE FIRDALE VILLAGE 5 ALSO LESS TH PTN LOT 3DAF - BEG AT NE COR OF S1/2 N1/2 OF SW 1/4 SE 1/4 TH SO1 *42 29W ALG E IN OF SD Property Description SW 1/4 SE1A 51OFT TH N88*26 50W 75FT TPBTH CONT N88*26 50W 104.06FT THS72*21 54E 108.30FT TH NO1*33 10E 30FT TPB TGW LOT 4 PLUS ADJ PTN VAC CUL-DE-SAC LESS PTN WHN FORSHEE FIRDALE VILLAGE 5 TGW LOT 5 PLUS PTN VAC CUL-DE-SAC & LESS PTN PROP PLAT FORSHEES FIRDALEVILLAGE NO 5 TGW LOT 12 TGW LOT 13 & NWLY 8FT LOT 14 TGW SELY 52FT LOT 14 Property Category Land and Improvements Status Active, Host Other Property, Locally Assessed Tax Code Area 100216 SHEET INDEX SHEET 1 VICINITY MAP, SITE PLAN, LEGAL INF❑RMATI❑N & NOTES SHEET 2 PLAN VIEW, ROOF PLAN SHEET 3 SECTI❑N, EQUIPMENT SCHEDULE SHEET 4 ELEVATI❑N, NOTES SHEET 5 ACCUREX EQUIPMENT INF❑RMATI❑N SHEET 6 ACCUREX AIRE EQUIPMENT INF❑RMATI❑N REVISIONS: RESUB Apr 19 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Q) o M N C: O p� (V 00 > M z Q Q Q L � z � � CD fu 0 73 Ld w0 a_ a a a� 0 w� � I 4-) ICJ C/D _ O C�2 � N CO O o 4 M a DRAWN BY: DOUG WALTER DATE: 12/ 15/23 TI TLE: COMMERCIAL KITCHEN EXHAUST SYSTEM SHEET: M-1 U Z J Q U Z Q U W W J Q U W z W 0 z 0 cn w W 0 Ir 0 W z Q z 0 W U) W 0 z Q Ld w w U) U) z 0 z 0 U) Q Q 0 0 w W U) w CD Iy J J Q f f /f f ` EE-1 TYPE I EXHAUST FAN ON ROOF , a X�i �j MINIMUM TO — ANY AIR INTAKE MUA 1 MAKE-UP AIR UNIT IN ATTIC w/ M INTAKE ON ROOF �1 � Y � X N 18x18 1 4 i0" 0" 0" 0" 04 0" 0" 0" 0" 0" 0" 0" 0" P" 0" 0" 0" 0" 0" 0" 0% P" 0" 0" 1 i The maintenance access platform for the hood i exhaust vent and mua units are provided on A1.2 and Al .3 i The plan view and detail for the rooftop platform are on A1.3 1 ROOF PLAN Scale 1/4" = F-0" NORTH PLAN VIEW Scale 1/4" = F-0" NORTH Equipment platforms and access paths will are not part of the mechanical permit and will be constructed under the TI permit. Applicable access shall be completed prior to final approval of the Mechanical permit. REVISIONS: RESUB Apr 19 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W O =3 N MM0 W W M z Q Q Q 0 ro L � z 17L 0 cD E � M �..0 W 0 LCJ c Ccc ��— O N C/D O W E===4 < 4-)� z �o � ILO o n LO o C9 DRAWN BY: DOUG WALTER DATE: 12/15/23 TI TLE: COMMERCIAL KITCHEN EXHAUST SYSTEM SHEET: m-2 0 Z J Q U Z Q U W W J Q U W z W 0 z 0 co Cn Ir W 0 Ir 0 W z z 0 W Cn W 0 z W W z 0 z 0 Q Q 0 0 W Ir W Cn W co n, J J Q TYPICAL HINGE KIT EQUIPMENT CURB EF-1 TYPE I EXHAUST FAN SECTION Scale 3/8" = F-0" MUA-1 MAKE-UP AIR FAN INTAKE Equipment platforms and access paths will are not part of the mechanical permit and will be constructed under the TI permit. Applicable access shall be completed to final approval of the Mechanical permit. TYPE I EXHAUST AND MAKE-UP AIR SYSTEM EQUIPMENT SCHEDULE HOOD NO SYSTEM TYPE HOOD CAPTURE SIZE HOOD WEIGHT WITH COMPONENTS EXHAUST DUCT SIZE EXHAUST DUCT WEIGHT EXHAUST AIR CFM EXHAUST DUCT VELOCITY EXHAUST FAN MAKE-UP DUCT SIZE MAKE-UP AIR CFM MAKE-UP DUCT VELOCITY MAKE-UP DUCT WEIGHT MAKE-UP AIR FAN FAN MAKE MODEL CFM HP ESP POWER RPM FAN WEIGHT FAN MAKE MODEL HP ESP POWER RPM MBTU'S UNIT WEIGHT EH-1 TYPE 1 12'-4" X 4'-6" CANOPY GREASE HOOD 426 LBS 15"x16" 185 LBS 2775 CFM 1666 FPM EF-1 ACCUREX XCUE-160-A 2775 2.0 1.382 208/3 1688 115 LBS 18' x 18' 2498 CFM 1111 FPM 200 LBS MUA-1 ACCUREX XDGX-P115-H12-MF 2.0 1.227' 208/3 1002 118.6 650 LBS REVISIONS: RESUB Apr 19 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W O � N o p� 00 > M z Q Q Q ru L Q. — 3: V) _0 z L o E LiJ L U 0 cc ��cc � a N 0f O W 0 z +' Ln UD O CQ Q � o a DRAWN BY: DOUG WALTER DATE: 12/15/23 TITLE: COMMERCIAL KITCHEN EXHAUST SYSTEM SHEET: m-3 C_) z Q U z Q U w W J cn Q W z L� 0 z 0 cn V) ry W 0 ry 0 L� z Q z 0 w w m I- 0 z Q LLJ w Cn z 0 z 0 _ Cn Q Q 0 0 LLJ ry III LLJ rK Cn CD ry J J Q GENERAL C❑NSTRUCTI❑N NOTES 1, The General Contractor shall provide building penetrations, roof ing, and other construction needs for installation of system equipment. 2, The General Contractor shall be responsible for maintaining structural integrity and provide required structural supports as required City of Edmonds, 3, The General Contractor shall be responsible f or other trades unless otherwise stated by the conditions of the general contract with the project owner. EXHAUST SYSTEM NOTES 1, The exhaust/rake-up air systems are to meet requirements of the International Mechanical Code, and NFPA-96, The Type I exhaust ductwork to be constructed of fully welded 16 gauge steel. 2, Exhaust rust be a minimum of 10'-0' f ror any air intake, adjacent building, or adjoining property. 3, Exhaust and rake -up air systems dust be electrically interconnected to be operated simultaneously by a single on/of f switch. ELECTRICAL NOTES 1, The electrical contractor shall provide and install interconnecting field wiring between the hood equipment control switches, and exhaust / make-up air system equipment contactors. 2. The electrical contractor shall install exhaust f an and make-up air system motor relays and disconnect switches. 3. The electrical contractor shall verif y proper f an motor rotation. IMC 2018 SECTI❑N 507.1.1 ❑PERATI❑N, (PARTIAL) THE EXHAUST FAN SERVING A TYPE I HOOD SHALL HAVE AUT❑MATIC CONTROLS THAT WILL ACTIVATE THE FAN WHEN ANY APPLIANCE THAT REQUIRES SUCH TYPE I HOOD IS TURNED ON, OR A MEANS OF INTERL❑CK SHALL BE PR❑VIDED THAT WILL PREVENT ❑PERATI❑N OF SUCH APPLIANCES WHEN THE IS NOT TURNED ON.. TYPE I EXHAUST AIR DUCTWORK TO BE MAKE-UP AIR DUCTWORK TO BE FULLY WELDED 16 GAUGE STEEL FULLY SEALED 22 GAUGE STEEL DUCTWORK TO BE C❑NTINU❑US INTERNAL MAKE-UP AIR DUCTWORK TO BE INSULATED OR EXTERNAL LIQUID -TIGHT WELDED SMOOTH, ACCESSIBLE FOR INSPECTI❑N, AND WITH❑UT GREASE TRAPS FireMaster® FastWrap® XL Grease and HVAC Duct Enclosure System 1 or 2 Hour Shaft Alternative / Zero Clearance to Combustibles LEGEND TWO LAYER INSTALLATION (Grease Duct per ASTM E2336) 1 Two Layers of XL Insulation for ASTM E2336 and CAN/ULC S144 Grease Duct Enclosures One Layer of XL Insulation for 2-Hour Air Ventilation Duct Enclosures 2 Steel banding minimum 1/2" (13) wide by 0.015" (0.4) thick. 3 Tight butt joints (no overlap) at perimeter and longitudinal joints, both layers for grease ducts 4 Min. 3" (75) overlap on perimeter and between adjacent blankets 5 Optional 6" XL collar 6 Hangers - size dependent weight of assembly (see datasheet Section G) 7 Trapeze Supports - size dependent on weight of assembly (see datasheet Section G) 8 Steel Rectangular or Round Duct (size, gage and construction dependent per Listed Design) ONE HOUR FIRE RATED DUCT WRAP Not <aScale MUA-1 MAKE-UP AIR FAN INTAKE 10'-0" EH-1 TYPE I EXHAUST HOOD EH-1 TYPE I EXHAUST HOOD IS ZERO CLEARANCE SEE SHEET M-5 C❑❑KLINE EQUIPMENT ELEVATION Scale 1/2" = F-0" TYPICAL HINGE KIT EQUIPMENT CURB REVISIONS: RESUB Apr 19 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O � N M) 00 / M z Q Q 0. - 3: ru L V) z L ~ TI O 0 E 0 W w0 cc cc O o o N � 4-) i/D O � W � U Q U +' N I z � � � O � U� � o cat U o Q 3:o a DRAWN BY: DOUG WALTER DATE: 12/15/23 TITLE: COMMERCIAL KITCHEN EXHAUST SYSTEM SHEET: M-4 z J z Q U w W cn U W z W 0 z O V) ry W O O w z Q Z 0 w w m I- O Z Q W W Un to Z O Z O (n Q Q 0 0 w > W W (n W W (n CD W J J Q Direct Drive Upblast Centrifugal Roof Exhaust Fan MARK INFORMATION FAN INFORMATION MOTOR INFORMATION QTY MARK MODEL VOLUME TOTAL EXTERNAL SP FAN OPERATING WEIGHT SIZE (HP) V/C/P ENCLOSURE MOTOR WINDINGS NEC FLA* (CFM) (IN WG) RPM POWER (HP) (LB.) RPM 1 EF - 1 XCUE-160-A 2,776 1.382 1,432 1.1 115 2 208/60/3 OP 1725 1 7.5 *NEC FLA - Based on table 430.250or 430.248of National Electrical Code 2020. Actual motor FLA may vary for sizing thermal overload, consult factory" EF - 1 : SELECTED OPTIONS AND ACCESSORIES Motor VFD Rated without Shaft Grounding Protection One piece fully welded windband Tapered bushing wheel hub Breather tube outlet area min. 4.4 sq. in. (sizes 99-480), 2.0 sq. in. (sizes 60-95) Min. windband material thickness: 0.051" aluminum (060-240), 0.064" aluminum (240HP, 240XP), 0.080" aluminum (sizes 300-480) Larger Curb Cap Size - 26 Square UL/cUL 705 Listed - Supplement SC - "Power Ventilators for Restaurant Exh. Appliances" (Formerly UL 762) Switch, NEMA-3R, Toggle, Hinge, Factory Installed High Temp Curb Seal Rated for Continuous Duty at 1500 F (Factory Attached) Grease Trap (PN 475538) Conduit Chase Qty 1 _L MAIN POWER L: TO UNIT - - 208V L: GROUND RH HLC1 PS2 .L.2 RED RED 2.3 R R .24 RED O- 11 14 C NO PS2 RED .�7 NC C OSENSE TH/24V o GND (BURNER) -0ALM FSG GND -0 SPARK MV Q PV Q (24V) TR6 INT 10 SEC AMP 7 39 BLUE 24 VAC ® ® DISCHARGE STAT. TEMP RANGE 55-90' F 1 2 3 4 5 6 8 38 YELLOW O O O O O O AN !AL TO Y FAN VLET DAMPER iUPPLY FAN RELAY 'OST HEAT DIRECT GAS CONTROL 028.88 24.75 24.75 29.75 19.56 3.44 53.75 24.00 O O a (24.00) 30.09 28.75 L26.00 SQ ACCUREX Wiring Diagram Code: AD61 N401 Y310N 10NM26 CAUTION UNIT SHALL BE GROUNDED IN ACCORDANCE WITH N.E.C. POWER MUST BE OFF WHILE SERVICING. NOTES USE COPPER CONDUCTORS ONLY 60° C FOR TERMINALS RATED LESS THAN 100 AMPS. 75° C FOR TERMINALS RATED 100 AMPS OR MORE. FIELD CONTROL WIRING RESISTANCE SHOULD NOT EXCEED 0.75 OHM. FIELD WIRED - - - - - FACTORY SUPPLIED AND WIRED NOTE: #1 FOR EXTERNAL HEAT ENABLE - REMOVE R TO W1 JUMPER AND INSTALL EXTERNAL CONTACT. WIRE COLOR CODE BK BLACK BL BLUE BR BROWN GY GRAY LT BLLIGHT BLUE O ORANGE PK PINK PR PURPLE R RED W WHITE Y YELLOW LEGEND AMPAMPLIFIER D1 INLET DAMPER DS1MAIN DISCONNECT SWITCH FSCFIRE SYSTEM CONTACT FSGFLAME SAFE GUARD HLCHIGH LIMIT CONTROL M# MOTOR MODMODULATING VALVE PS2 AIR PROVING SWITCH RF SUPPLY FAN RELAY RF1FAN ENABLE RELAY RH HEAT RELAY S2 FAN SWITCH S4 HEAT AND COOL SWITCH SG SPARK GENERATOR TR#TRANSFORMER TS2DISCHARGE AIR SENSOR TS4INLET AIR SENSOR - HEAT V1 PILOT VALVE V2 MAIN VALVE VFDVARIABLE FREQUENCY DRIVE Wiring Template: M26 DOC NUMBER: ---- REV: ---- Hnnn INFnRI\AATinN HOOD NO. MARK MODEL HOOD DIMENSIONS (IN.) HOOD CONSTR. COOKING LOAD / DUTY RATING EXHAUST SUPPLY TOTAL WEIGHT LBS. SECTION LOCATION LENGTH WIDTH HEIGHT TOTAL COLLAR(S) MUA CFM AC CFM CFM WIDTH LENGTH DIA. CFM S.P. 1 H - 1 XXEW-148-S 148 54 FRT 12 430 SS WHERE EXPOSED HEAVY 2775 9 27 2775 0.651 2498 426 SINGLE BACK 24 HOOD INFORMATION HOOD NO. MARK LIGHTING DETAILS GREASE FILTRATION DETAILS UTILITY CABINET(S) FIXTURE TYPE BULB / LAMP INFO QTY FOOT CANDLES TYPE / MODEL MATERIAL QTY SIZE (IN.) FIRE SYSTEM CONTROLS L H LOCATION TYPE SIZE MODEL INTERFACE 1 H - 1 INCANDESCENT (GLOBE) 100W Al (BULBS NOT INCL.) 7 61.06 X-TRACTOR (SPARK ARRESTOR INCL.) STAINLESS STEEL 3 16 20 5 20 S11PP1 Y PI FNI IM INFnRMATinN HOOD NO. MARK POS. TYPE SIZE (IN.) INSULATED AMPER(S) LED LIGHT(S) TOTAL CFM TOTAL S.P. COLLARS L W H SUPPLIED QTY MOUNTING TY W L DIA CFM VEL. 1 H - 1 FRONT ASP 75 14 4 NO YES NO 1249 0.02 qUA LOOSE 2 12 24 625 313 1 H - 1 FRONT ASP 75 14 4 NO YES NO 1249 0.02 LOOSE 2 12 24 624 313 HOOD OPTIONS EQUIPMENT SCHEDULE Tempered Make -Up Air Unit Mark:MAU - 1 Qty Accurex Model Volume External SP Total SP MCA MOP Weight SCCR 1 XDGX-P115-H12-MF 2,498 CFM 0.5 in. wg 1.227 in. wg 10.1 15 650 lb 5kA Motor Information Size V/C/P Enclosure Motor with Shaft Grounding Motor RPM Operating Power 2 hp 208/60/3 ODP No 1725 0.78 hp Heating Temperature Energy Connectio Building Control Gas Pressure Type Gas Type Gas (IN) Gas Pressure Access Winter DB Max A Max LAT Input Output Efficiency Min Max Direct Gas Natural 24.5 F 45.5 F 70.0 F MBH MBH 92% 3/4" 1/2 PSI Had 7 in. wg 0.5 PSI Outlet Sound Power By Octave Band LwA dBA Sones 62.5 125 250 500 1000 2000 1 4000 1 8000 75.1 71.6 70.2 74.4 70.6 70.5 1 71.8 1 67.1 78.1 67.1 15.4 �LwA - A weighted sound power level based on ANSI S1.4 dBA - A weighted sound pressure level base on 11.f dB attenuation per octabe band at 5.0 ft. Noise Criteria (NC) based on an average attenuation of 11.5 dB per octabe band at 5.0 ft. OPTIONS AND ACCESSORIES Air Flow Arrangement: Variable Volume Supply Fan Control: VFD Temperature Control: Discharge Weatherhood: Aluminum Mesh, 16x20x2 - (4) VFD Control: External 0-10 VDC Direct Gas Options/Accessories Damper: Inlet Access Side: Right -Hand Approvals: ETL Outdoor Air Intake Position: End Unit Weight: 650 lb FM Compliant Discharge Position: End Control Center Flame Sensing: Flame Rod Coating: Galvanized Heat Inlet Air Sensor Ignition Control: Pilot Insulation: Double Wall - Tempering On Unit Controls: Terminal Strip Unit Rated Gas Pressure: 1/2 PSI PLAN VIEW ACCESS SIDE ELEVATION VIEW 96.125 2.500 - 39.02 UL 710 LISTED W/ OUT EXHAUST FIRE DAMPER - UL #R25625 HOOD TOP INSULATED FOR ZERO CLEARANCE TO COMBUSTIBLES BACK INTEGRAL AIR SPACE - 3 IN WIDE - ZERO CLEARANCE LEFT NON -INTEGRAL AIR SPACE - 1 IN THICK - ZERO CLEARANCE RIGHT NON -INTEGRAL AIR SPACE - 1 IN THICK - ZERO CLEARANCE SHIPPED LOOSE EXHAUST COLLAR(S) RIGHT FULL END SKIRT - 45.00 IN HIGH 48.50 IN TOP WIDTH 42.5 IN BOTTOM WIDTH HOOD FRONT IS TAPERED (FOR LOW CEILING APPLICATIONS) PERFORMANCE ENHANCING LIP (PEL) TECHNOLOGY STANDING SEAM CONSTRUCTION FOR SUPERIOR STRENGTH 1.0 AIR SPACE 33.241 28.192 SUPPLY DUCT 3" REAR INTEGRAL AIR SPACE 0 0 6.5 9.0 27.0 22 IN. OC TEMPERATURE SENSOR FIELD WIRING TO CONTROLS REQUIRED 0 0 0 0 12. 0 12.0 0 0 12. o 12. 0 I� 24.0 �I r I� 24.0 �I f MARK: H - 1 - SECTION 1 PLAN VIEW 148.0 150.0 sue 12.0 PERFORATED AIR CURTAIN I� 24.0 �I t I� 24.0 �I 3.0 54.0 68.0 0 14.0 TEMPERATURE SENSOR(S) 4.0 1.0 AIR SPACE N� L.L Z U) Z_ 0) 0 M � O H U U X w Lij �:zE �F-U� O Urn Ha t UQZZN J WLO Uz�� < LU a n j LU Q Z U Q UL LISTED LIGHT FIXTURE CHROME APPLIANCE DROPS 78.0 90•0 UL LISTED HIGH EFFICIENCYC. ABOVE 'GREASE-X-TRACTOR' FILTERS FINISHED 2.500 FLOOR REMOVABLE GREASE CUP W/ 3.250 11CONCEALED GREASE TROUGH ZERO CLEARANCE INTEGRAL AIRSPACE 39.020 FULL END SKIRT 30.931 4< MARK: H - 1 SECTION VIEW jdAl REVISIONS: RESUB Apr 19 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 =3 N MO W W z Q Q Q C1) L fu Cn M0 z L O C) E ~ k10 M0 W Uj D O IY 70 cc O r--1 C� O {) Wco w z � +' o L o � .-. c� � oCQ WSJ U 3: M 4 a DRAWN BY: DOUG WALTER DATE: 12/15/23 TI TLE: COMMERCIAL KITCHEN EXHAUST SYSTEM SHEET: M-5 O z J Q 0 z Q 0 w w J I- V) Q 0 w z w 0 z O V) cn 12 Ir w D 0 n, O w z Q z 0 w V) D w m O z Q w w Z O z O V) Q Q 0 w w U) w V) Ir J J a ELECTRICAL CONTROL PACKAGE USER INTERFACE FANS CONTROLLED MARK MODEL LOCATION TYPE LOCATION FAN # TYPE FAN FAN MARK ZONE CFM MOTOR HPKIOTOR VOLTC CLEMO OR PHASEMOT R STARTER IN PANEL VFD IN PANEL CC - 1 XKC-DCV-S-11-1-1-0 SHIP LOOSE ENCLOSURE FULL COLOR TOUCHSCREEN FACE MOUNT ON CONTROL PACKAGE 1 EXHAUST E1 EF - 1 1 2776 2 208 50 3 NO YES 2 SUPPLY S1 MAU - 1 1 2220 2 208 60 3 NO NO CONTROL FEATURES HOOD LIGHT CONTROL TEMP SENSORS (FACTORY INSTALLED) - QTY. 1 DRY FIRE CONTACTS - QTY. 1 LIGHTS OFF DURING FIRE EXHAUST MAX DURING FIRE SUPPLY OFF DURING FIRE DOC NUMBER: ---- REV: ---- THESE DRAWINGS SHALL NOT BE REMOVED FROM THIS EQUIPMENT. USE COPPER CONDUCTORS NE PAS RETIRER CES DESSINS DE CET EQUIPEMENT. SAUF INDICATION CONTRAIRE, WIRING DIAGRAM CODE: WDC# RATED TO 90°C UNLESS SPECIFIED. TORQUE CONTROL & GROUND BLOCKS TO 8 LBS. IN. TORQUE UTILISER DES CONDUCTEURS EN CUIVRE CLASSES 90 °C. SERRER LES BORNES DE COMMANDE ET DE CAUTION ATTENTION JOB NAME: ACCUREXCOMMERCIAL UNIT MUST BE GROUNDED IN ACCORDANCE WITH N.E.C. POWER MUST BE OFF WHILE SERVICING. L'APPAREIL DOIT ETRE MIS A LA TERRE CONFORMEMENT AU CODE C.E. L'ALIMENTATION POWER LUGS/SCREWS TO COMPONENT RATINGS LISTED. TORQUE CONTROL BOARD SCREW TERMINALS TO 3.5 LBS. IN. FIELD CONTROL WIRING RESISTANCE SHOULD NOT EXCEED 0.75 OHM. SEE A MISE LA TERRE A 8 LB -PO. SERRER LES COSSES/VIS D'ALIMENTATION AUX COUPLES INDIQUES POUR LE COMPOSANT. SERRER LES T I R I N I S PANTRY -REV 4 DOIT ETRE COUPEE DURANT UENTRETIEN. IOM FOR ADDITIONAL INFORMATION, OR CALL A VIS DE LA CARTE DE COMMANDE MODEL: XKC-DCV-S-11-1-1-0 APPLIANCE OUTLET CENTER FACTORY AT 1-800-371-6858. A 3,5 LB COMMANDE LA RESISTANCE A CABLAGE DE LOCAL PAS SERIAL NUMBER: WDSN# PRG VERSION: V4 1/� ELECTRICAL RATINGS: 110-240V,1 PHASE, 50-60HZ,15A 0 US ?0 75OHM. S 'INF TION, CON o,75 OHM. POUR PLUS D'INFORMATION, CONSULTER MARK:CC - 1 43BM BASE FILE #E200616, ML FILE #E313951 FIELD WIRED (CABLE LOCALEMENT) FACTORY WIRED (CABLE A L'USINE) LE MANUEL OU APPELER 1-800-371-6858 POWER WIRING FOR KITCHEN CONTROLS POWER WIRING FROM BREAKER CONTROL WIRING FOR KITCHEN CONTROLS MAIN (WIRING TO BE DONE BY ELECTRICIAN) PANEL DIRECT TO FANS (WIRING TO BE DONE BY ELECTRICIAN, CONTROL PANEL FIRE SUPPRESSION MAIN IF NO CONTROLS CONTRACTOR. (CONTINUED) FIRE SYSTEM SWITCH BUILDING (WIRING TO BE DONE BY ELECTRICIAN) USE CONTROL PANEL 18-22GA WIRE UNLESS SPECIFIED.) Mg (REMOVE JUMPER IF USED)** BUILDING MAIN BREAKER PANEL (MAIN BOARD) WILL BE BREAKER PANEL CONTROL PANEL L HOOD NC FACTORY FS-C WIRED IF 110V-120V / 1 PH HOT BLACK LIGHTS FS-NC C MOUNTED POWER FOR H1 LTS-H L 115VAC NO NEXT TO NEUTRAL WHITE CONTROLS / 9LTS-N 120OW MAX FIRE SYSTEM LIGHTS GROUND GND GND GREEN (NON SHUNTED 15A BREAKER) MARK: MAU - 1 TS-1A HOOD 1 RUN S1-RA COMMON SUPPLY S1 TS-1 B TEMP SENSOR 208V / 3PH LINE 1 SUPPLY S1 OUTP� S1-RB NORMALLY -OPEN HOOD MARK: UPON FIRE COMMON FIRE SYSTEM POWER FOR S1 LINE 2 FAN SPE&S1-S+ MUA 0-10VDC + 46 H - 1 SECTION 1 OR NO POWER TO PANEL: C1 NORMALLY OPEN DRY M MCA: 10.10 LINE 3 7.5 FLA 0-10VDC OU UNIT 0-10VDC - (COM) 47 C TO NO WILL CLOSE N01 NORMALLY CLOSED CONTACT 1* NC1 MOP: 15 GROUND DS 2 HP 208V / 3PH C TO INC WILL OPEN MARK: MAU - 1 MARK: EF-1 208V / 3PH LINE 1 VFD LOAD 1 EXHAUST E1 L1 T1 POWER FOR E1 LINE 2 LOAD 2 L2 EXHAUST E1 T2 M MCA: 9.38 LINE 3 L3 T3 LOAD 3 7.5 FLA MOP: 15 GROUND GND GND GROUND DS1 2 HP 208V Screening: Per ECDC 22.100.050(C)(3), roof -mounted mechanical equipment, meters and similar structures and other similar elements shall be located so as to not be visible from the street, (OPTIONAL ON/OFF INPUTS) public open space, parking areas, or from the DIGITAL IN 1 DI-1A ground level of adjacent properties. Screening DI-1B C NO FAN ON/OFF(DEFAULT) features shall blend with the adjacent buildings DIGITAL IN 2 and project as a whole. D1_2B c No LIGHT ON/OFF (DEFAULT) APPROVED BY PLANNING May 08 2024 *FIRE SYSTEM DRY CONTACT WIRING EXAMPLES SHUNT TRIP APPLIANCE CONTACTORS (BY OTHERS) (BY OTHERS) WIRING EXAMPLE: WIRING EXAMPLE: C1 COMMON HOT C1 COMMON HOT N01 NORMALLY OPEN i� NEUTRAL NC1 NORMALLY CLOSEDNEUTRAL **WHEN FIRE SYSTEM IS SHUNT TRIP APPLIANCE ARMED, FS-C TO FS-NC BREAKER COIL CONTACTOR COIL SHOULD HAVE CONTINUITY CABINET DETAILS 0 0 0 0 0 00 000 O O O O O MOUNTING LOCATION: SHIP LOOSE ENCLOSURE AInTGC- DRAWING NOT TO SCALE 9 TOTAL WEIGHT: 35 LBS 1) WHEN CONTROLS ARE MOUNTED IN HOOD -MOUNTED OR WALL -MOUNTED UTILITY CABINET, FOR HOOD OR WALL CABINET DIMENSIONS SEE HOOD SUBMITTAL. 2) MINIMUM OF 36" OF CLEARANCE RECOMMENDED IN FRONT OF CONTROL CABINET ZONE # ZONE ROOM TEMP 1 Z1 PRESET USER INTERFACE DETAILS MOUNTING TYPE FACTORY MOUNTED: FACE MOUNT ON CONTROL PACKAGE USER INTERFACE CONTROL FANS AND LIGHTS INTERFACE CABLE LENGTH 4FT (FACTORY PROVIDED) HOOD CONFIGURATION HOOD # HOOD HOOD MARK =ZONE EXHAUST SUPPLY MB-TEMP SENSORS HCB 1 H1 I H - 1 SECTION 1 1 Z1 E1 S1 TS1 NO WIRING DIAGRAM CODE: WDC# JOB NAME: TIRINIS PANTRY - REV 4 MODEL: XKC-DCV-S-11-1-1-0 SERIAL NUMBER: WDSN# MARK:CC - 1 DOC NUMBER: ---- REV: ---- DEFAULT SETTINGS / PARAMETRES PAR DEFAUT FACTORY SETTINGS TYPE:VAV CONFIGURATION: STANDARD ZONES: 1 HOODS:1 SUMPS: 0 EXHAUST FANS: 1 SUPPLY FANS: 1 MB ROOM SENSOR: NO MB TEMP SENSORS: 1 HIGH TEMP FAULT: NO FREEZE PROTECTION: YES GAS RESET: NO FAN PROVING: NO BMS:NONE ZONE SETTINGS SEE ZONE CONFIGURATION IN TABLE ON LEFT HOOD SETTINGS SEE HOOD CONFIGURATION IN TABLE ON LEFT EXHAUST FAN SETTINGS SEE FAN CONFIGURATION IN TABLE ON LEFT SUPPLY FAN SETTINGS SEE FAN CONFIGURATION IN TABLE ON LEFT SENSOR SETTINGS SEE HOOD CONFIGURATION IN TABLE ON LEFT USER INTERFACE SETTINGS (MB) FAN & LIGHT BUTTONS: SHOW BOTH (SEPARATE) USER INTERFACE SETTINGS (HCB) NA GENERAL SETTINGS TIME ZONE: CENTRAL DAYLIGHT (DEFAULT) FIRE/FAULT SETTINGS EXHAUST DURING FIRE: MAX SUPPLY DURING FIRE: OFF LIGHTS DURING FIRE: OFF BMS SETTINGS NA PRG VERSION: V4 FAN CONFIGURATION FAN # TYPE FAN FAN MARK ZONE MIN CFM MAX CFM MODBUS VFDVFD ADDRESS MIN FREQ. MAX FREQ MIN VDC MAX VDC 1 EXHAUST E1 EF-1 Z1 1388 2776 YES 1 25 50 - 2 SUPPLY S1 MAU - 1 Z1 1110 2220 NO - - - 0.0 10.0 z rn O CO O U) U LU Lu co LU 0 < C° U Q zN J LU UzN� QLLJ — �- � n LUJ z LU U � Q V V Q 2 Al REVISIONS: RESUB Apr 19 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT LCJ Cc cc r-I 0 F� 0-) � W � U N W z O � +' O in 0 o .-. O O C9 C-) O Q 3 4 a DRAWN BY: DOUG WALTER DATE: 12/15/23 TITLE: COMMERCIAL KITCHEN EXHAUST SYSTEM SHEET: m-6 FAI ❑I (N) WOOD CLEAN OUT ACCESS PANEL (24'x24') LOCATED IN ATTIC PER WOOD INSTALLER - WB FR 800, 610, AND 620 ACCESS DOORS ARE FLUSH MOUNTED AND HAVE MOUNTING WOLE5 FOR INTSTALLATION - INSULATED AND RATED BY UNDERWRITES LABORATORIES FOR 1.5 HOUR 'B' LABEL IN IN WALLS AND MAY BE USED IN 2 HOUR FIRE RATED WALL ASSEMBLIES 02 (N) WOOD CLEAN OUT ACCESS PANEL (24'x4V) - WB FR 600, 010, AND 620 ACCESS DOORS ARE FLUSH MOUNTED AND HAVE MOUNTING HOLES FOR INSTALLATION - IN5ULATED AND RATED BY UNDERWRITES LABORATORIES FOR 1.5 HOUR 'B' LABEL IN WALLS AND MAY BE USED IN 2 HOUR FIRE RATED WALL ASSEMBLIES II II II II II II II II II II II II II II II II II II II II II II II II (E) WALLS BELOW II II II II II II I I J I I I r— ----------- IIIfJ jL---- ----------------------------------------------------- ----� r-----------------------��-----------� r---------� I I II I I r-----------, r-------------------------------------� r----' II II II II IIII II II II II II II II I U I II II II II II II II II II II II II LJ II II II II II II II II II I1 II II II � I I L J I I I I I II I Q I -� r------------ I I II r1------------ 1 ``� I r-�------------- I I I I jI r------------I I I II II � I II �I I� II II 1J _ j I I II II �� 1 L----------' I TZ------------ I I I F I II II II II �`�� II II II II II II II o� II II II ---------------- ---------------- II I II II II ------------------------� i 1J II II O 1 O II II I I I I � I � O I I I I -r-----------J L---------�� I I �Z-----------J I I I e (N) 2-WR FIRE -RATED CHASE FOR (N) KITCHEN HOOD EXHAUST DUCTS - SEE DTLs G/A32 4 H/A3.2 (N) MAKEUP AIR UNIT FOR HOOD ----------- I A r- L - - - - Al2-----�- (N) MAINTEANCE PLATFORM: (N) 3/4' PWD SWTG OVER (N) 2x10 HK JOISTS 6 24' OC OVER (E) 2x6 CLG JOISTS FOR (2) BAYS MIN 4 22' MIN PLATFORM WIDTH (CTV) (N) 2x4 WALL W/ (N) 5/V TYPE 'X' GWB 6 ATTIC SIDE FOR (N) DRAFT STOP Luminaire controlled by a switch and receptacle outlet shall be provided at or near the appliance. IMC 306.3.1 ATTIC FLOOR PLAN 5C,4LE: 1/4" =1' -0 77 %2; �%;� 0 P t 4a] N ❑ ❑ (E)1WR RATED SEPARATION WALLS I� �I (E) PULL -DOWN ATTIC ACCE5 I I I I -J (N) MAINTEANCE PLATFORM ACCESS WALKWAY- (E) 16 S/L OVER (E) CLG FRAMING W/ (N) 3/4 PWD 5HTG TO MATCH WHERE MISSING (AS NOTED 0 ) (E) 2x4 WALL FOR DRAFT STOP W/ (E) 5/8' TYPE 'X' GWB ATTIC SIDE (E) 2x4 WALL FOR DRAFT STOP W/ (E) 5/6' TYPE 'X' GWB a ATTIC SIDE ONLY ❑o❑ ❑ ❑ ❑ N------ 0 aj 6., NOTE5: ❑ (N) 3/4" T4G PWD FLOOR 5HTG W/ 0.1314-1/2" P-NAILS ,@ 6" OC PNL EDGES 4 FIELD (NO BLKG ROD) 0 (N) 2x10 HF#2 J015T5 0 16" OC W/ (N) H2.55 6 0 - (N) 2x10 BLKG ® BTWN J015T5 ALONG ALL OPEN 51DE5 W/ (N) H2.5s TO ❑ 0 (E) 2x6 CEILING J015T5 6 16" OC PER PLANS SUPPORTING 0 - 5KLD2020-0999 ACCOUNTED FOR HOOD ACCE55 LOADS 4 ATTIC LIVE LOADS ARE EQUAL TO PLATFORM DE51GN LOADS ® (N) 2x10 HF#2 BLKG BTWN ❑ ALONG ALL OPEN SIDES W/ (N) H2.5s TOE W/ (3) 0.140x3 P-NAILS EQUALLY SPACED TO ENDS OF ❑ ATTIC MAINTENANCE PLATFORM NTS (E) STORAGE NO WORK (E) STORAGE NO WORK UNIT 9613 NO WORK (N) 2-HR FIRE -RATED CHASE FOR (N) KITCHEN WOOD EXHAUST DUCTS - SEE DTLs G/A3.2 4 H/A3. (E) WRAPPED COLUMNS FOR I5T FLOOR BALCONY - NO WORK (E) STORAGE E) MASSAGE RM3 Equipment platforms and access paths will are not pares of the mechanical permit and will be constructed under the TI permit. Applicable access shall be completed prior to final approval of the Mechanical permit. Required insulation shall be maintained (E) MASSAGE RM2 (E) MASSAGE RM1 (E) RECEPTION UNIT 9631 4, (E) WRAPPED COLUMNS - FOR BALCONY - NO WORK FLOOR PLANS FOR REFERENCE ONLY FOR 2-HOUR CHASE FOR KITCHEN WOOD - PLANS PART OF PERMIT 15LD2020-0999 H co O J U 77 u .ED (E) OFFICE3 (E) BTHRM (N) FIXTURES (E) OPEN OFFICE SPACE UNIT 9625 04-I8-24 CITY REVIEW COMMENTS (E) WINDOWS TO REMAIN - TYP UNO (E) OFFICE2 (E) BTHRM (E) KITCHEN 4 (E) PULL -DOWN ATTIC ACCESS (E) FRONT OFFICE UNIT 9619 (E) 2ND FLR BALCONY NO WORK (E) CLOSET LU J U OO PARTIAL UPPER FLOOR PLAN O� I (E) BTHRM 5c,4LE: 1/4" = V -0" (E)1HR RATED 2x4 EXT WALLS SEE WALL LEGEND ON AI.O FOR BAL OF INFO (E)1HR RATED SEPARATION WALLS 5EE WALL LEGEND ON AI.O FOR BAL OF INFO (E)1-WR RATED CEILING (E) OFFICE2 (E) FRONT OFFICE UNIT 9613 L (N) MOOD EXHAUST UN1T5 ABOVE ROOF W/ (N) MAINTENANCE PLATFORM PER I MC 306.5.1 (N) GRID TOP BAR 70 O/F OF (N) GIRD P05T W/ I-(N) E 0 FLG- (N) GRID MID BAR TO I/F OF (N) GIRD P05T W/ I-(N) E 0 FLCs (N) GRID P05T TO O/F OF (N) PLTF BEAM W/ (1) BOLT (N) PLTF BEAM 7O O/F OF (N) PLTF POSTS 4 O/F OF (N) PLTF PURL INS W/ (1) BO (N) PLTF PURL INS @ 4' OC i I/F OF (N) PLTF 5EAM5 4 0 (N) PLTF P05T5 WHERE AL W/ (1) BOLT e FLG- (N) PLTF POSTS o 6' OC M, (N) PLTF P05T PL- - (1) BC (1) LAG BOLT EA END AS Ic (N) 4x,5 (PT) HF*2 BLKG BELOW (N) PLTF P05T PL- W/ (N) L526Z CRD PLTF GUARDRAIL PLATFORM O/F I/F OUT51DE FACE INSIDE FACE HGR- EA END '@ (E) RAFTERS PL- PLATES FLG5 FLANGES NOTES: ALL STEEL A36 (Fy - 3(ok5i) W/ SHOP PRIMED/PAINTED SURFACES FOR EXT. EXPOSURE ALL BOLTS 5/0"� A325 W/ HVY HEX NUTS $ PL WASHERS (ALL GALANIZED) W/ BOLTS @ I" GAGES COPE FLG- AS ROD FOR TIGHT FIT CONDITIONS (CTV) - NO FIELD WELDING SHOWN (AVOID) USE ADD'L ANGLES AS PL- OR CUT ANGLES FOR PL- -OR= BARS AS ROD (CTV) (N) ANGLE5 AS BRACES BTWN (N) PLTF POSTS TO O/F OF (N) PLTF POSTS W/ (1) BOLT FLG- ALL LAG BOLTS 5/a"�x4" (GALV) 7HRU (E) ROOF 5HTG 70 (N) BLKG HOOD EXHAUAST ACCESS PLATFORM N75 (N) CONT RIDGE VENT ROOFING 4 5HTG KEPT BACK MIN 1" EA SIDE OF RIDGE SPLINE FOR AIRFLOW RIDGE VENT DETAIL N75 (N) COP -VENT IN-VE`r ^� EQUIVALENT IN5TALLEI MFR GUIDELINES I" CONT AIR SLOT FOR (N) COR-A-VENT (E) CRIPPLE WALLS - (E) EXT WALLS @ 51M 3'-0" 51M COND IN -VENT DETAIL NT5 (N) HVAC SCREENING ALONG (3) SIDES- NORTH, EAST, & WEST ATTACHED 70 (N) STEEL PLATFORM GUARDRAILS W/ SCREENING PER ECD5 22.100.050(CX3) THE MECHANICAL EQUIPMENT WILL AL50 BLEND IN W/ THE ROOF & WILL NOT BE FULLY VISIBLE DUE 70 (3) STORIES 4 1 DORMER ROOF DOWN5LOPE Ai OUTLINE OF (E) EXT WALLS (E) LOWER ROOF NOT SHOWN FOR CLARITY (NO WORK) (N) IN -VENT COR-A-VENT 3'-0" UP — 5LOPE OF (E) EXT WALL - CTV 1" NET AIR CLEARANCE B7UN INSULATION 4 ROOF 5HTG (N) 2-HIR FIRE -RATED WOOD -CHASE W/ (N) FLASHING 4 CRICKE75 PER CONTR FOR (N) KITCHEN MOOD EXHAUST DUCTS - SEE DTL G/A3.2 4 H/A3.2 FOR BAL OF INFO (N) TYPE 1 HOOD MAKE-UP AIR UNIT — (BY OTHERS) APPROX 120"x30" OVER PRE-FAB CURB - (N) 57L ACCESS PLATFORM PER IMC 306.5.1 PER DTL C/A1.3 (THIS SHEET) - (N) FLASHING ROOF PENETRATIONS PER CONTR (N) CRICKETS 4 (N) FLASHING PER CONTR 2'-(o" MIN / 3'-0" MAX 0 0 z � z o � z (N) PLTF CRD- (1) SIDE ONLY A5 (DOWN5LOPE SIDES) — — — — — — — — — — — — ` (N) PLTF BRACES AS SHOWN W/ OPP, Ai ORIENTATION 57WN P0575 (CTV) (N) 7F POSTS a 6' OC MAX AS SHOWN EEI PL P W/ (N) PLTF BRACES BTWN ALL POSTS (N) IN -VENT COR-A-VENT 1'-0" UP A SLOPE OF (E) ATTIC CRIPPLE WALL - A13 CTV 1" NET AIR CLEARANCE 57WN INSULATION 4 ROOF 5HTG \ z 1'-0" OUTLINE OF (E) CRIPPLE WALLS-7 (N) DIMENSIONAL COMP ROOFING - 7YP UNO (E) GUTTERS 4 DOWN5POU75 TO (E) TIGHTLINE5 ROOF DRAINAGE &VENTILATION PLAN N?5 Equipment platforms and access paths will are not part of the mechanical permit and will be constructed under the TI permit. Applicable access shall be completed prior to final approval of the Mechanical permit. Al 04-18-24 CITY REVIEW COMMEN76 (E) LOWER ROOF NOT SHOWN FOR CLARITY (NO WORK) (E)/(N) 2x BLKG UP SLOPE OF (N) IN -VENT COR-A-VENTS 70 HAVE (3) 2 "� HOLES EA RAFTER BAY (CTV) (N) CON7 RIDGE VENT - CTV MIN NET WIDTH PROVIDED SKN) ROOF 5HTG - 7YP UNO (N) ROOF VENTILATION CALCULATIONS: VENTILATION REQUIRED: 2,134 S.F. (144/300) = 1,192.3 S.I. 50% OF AREA REQUIRED e RIDGE = 596.2 S.I. VENTILATION PROVIDED: 6i'-9" RIDGE VENT 6 18 S.I./5F = 1,219.5 S.I. 10'-10" EAVE VEN75 (EVERY BAY) 2.35 5.1./7 = 25.455.1. 94'-0" COR-A-VEN75 6 6.15 5.I./F7 = 634.55.1. TOTAL PROVIDED = 1 Si9.45 S.I. O �iN o (N) WALK-IN COOLER 51M 70 ORIGINAL PER o MFR OVER (E) 2x6 74G FLOOR DECKING 4 (E) 2xl2s 6 12" OC (CTV) - SEE BOXED NOTE t� FOR ENGINEERING ANALY515 �wN � CK) W RES Apr 19 2 ,f q CITY OF ED s DEVELOPMENT SE ICES O DEPARTM l\ (E) 6xl4 (FF) BM (NO DAMAGE) - Tl'P UNO � (E) OPENING FOR OLD HOOD 70 REMAIN W/ Li_ W/ (N) 2xlOs A5 NOTED PER ~ W APPROVED PLANS (CTV) O O N (E) 4"0 PIPE COLUMN5 (NO DAMAGE) Tl'P UNO �J W (N) HOOD PER MFR W/ (8) HANGER BRACKETS FOR 5UPPORT U51NG (N) UN15TRUT PER DTL 1/H1.0 0 q LEcg \ � w (N) P1000T UNI5TRUT5 @ (4) LOcs FOR (N) HOOD w W/ (N) P1283 UN15TRUT BRACKET5 (E) 2x10 J015T5 - SEE DTL 1/H1.0 f (N) PLENUM PER HOOD MFR W/ H10 TYP (8) PLGs HOOP q (4) HANGER 15RACKET5 U51NG 51M (4) PLCs PLENUM J C� (N) UN15TRUT 51M DTL 1/1-11.0 o N 0 (N) P1283 BRACKET TO (E) 2x105 (N) I/2"0 ALL -THREAD RODS -OR- ��, cl �o � & (N) P1000T UN15TRUT W/ THRU-BOLT5 FROM UN15TRUT 70 (N) 1/2"0 7HRU-5005 W/ NUTS & WA5HER5- (N) HOOD HANGER 5RACKET5 W/ = W N USE UN15TRUT NUT5 4 WA5HER5 NU75 4 WASHERS & UN15TRUT NU75/WA5HER5 ►� N PER MFR SPECS (CTV) IN511DE 57RU75 PER MFR SPECS (CTV) M--� W a� No cr� .,Z) ---- �f� O (N) P1000T 5LOTTED UN15TRUT PER (N) HOOD W/ (N) HANGER BRACKET5 F-+--� • Hoop SUPPORT PLAN LOCATED PERP. PER MFR (CTV) M� � TO (E) 2x10 J015T5 (CTV)LLJ o D o � � � o Q w �w (N) HOOD 5�f=f=OF,7 D 7,41 L (N) HOOD SUPPORT PLAN o Yi 5C"4LE: 1/4" = 1'-011 W o o SEE APPROVED PLANS FOR ADDITIONAL INFORMATION z �i o ALL BOLT5 SHALL BE A301 4 ALL BOLT5 -AND- NU75/WA5HER5 SHALL CONFORM TO HEALTH CODE 5TANDARD5 • w 4 HOOD MFR 5TANDARD5 FOR PROTECTION/ETC. w z o M z HOOD WEIGHT IS 500LB5 (E) MAIN FLOOR CON57RUCTION BELOW (N) WALK-IN COOLER: Q -44 (NJ COOLER 15 13'x�' (APPROX. 905QFt� 100P5F # 905QF7 = 9,000LBS EQUIVALENT o (N) COOLER 4 CONtEN75 LE55 THAN 9,000 L55 TOTAL (BY IN5PEC710N) 100P5F LIVE LOAD W/ EX15tING DEAD LOADS RE5ULt5 IN NO OVER-5tRE55 OF (E) J01575 � (N) COOLER HA5 4' FLOOR PANELS FOR WEIGHT p 157RUB710N 4 15 LOCATED CL05ER t0 AN (E) 6x14 FLOOR BEAM 50 W/ PANELS 4 74G DECKING THERE 15 NO 150LAtED POINT LOADS OR PO 551BLE 150AL7Ep pEFLEC710N/CRUSHING/E7C. BELOW (N) COOLER m q � w I o �� q o