REVIEWED BLD2024-0544+Manufacturer_Specifications_and_Installation_Instructions+3.13.2024_1.55.48_PM+412810546 UPFLC 4C 5 13.1C Tag: 25T RTU-2, 25T RTU-2-1 T/�ANE® CQuantity: Customer: Project: Name: Kruger Medical Building Remodel PLAN VIEW 11X7J&f11: IX59 PLAN VIEW OF UNIT 25 TON COOLING AND STEAM HEAT UNIT DIMENSION DRAWING RECEIVED Apr 25 2024 BLD2024-0544 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 8" 85 NOTES: 1. VERIFY WEIGHT, CONNECTION, AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 2.OVERALL UNIT WIDTH INCREASES 5/8" BEYOND LIFTING LUG WITH ULTRA LOW LEAK POWER EXHAUST DAMPERS 3. IF FIELD CONVERTING SUPPLY& RETURN OPENING(S)TO HORIZONTAL OR VERTICAL AIRFLOW, FACTORY MUST VERIFY IF UNIT OPTIONS WILLALLOW IT. FACTORY INSTALLATION IS ALWAYS RECOMMENDED. /4" �88 112"� 3 7/8" 3/8" DRAIN HOLES BOTH SIDE) FRONT VIEW SEE NOTE 3-/ 1/8" CONDUIT C CONTROL CIRCUIT 1/8" CONDUIT .0 CONTROL CIRCUIT 1/8" CON DU ITAC & C CONTROL CIRCUIT 1 /8" CONN. THRU IASE FOR POWER SUPPLY Created: 1/9/2024 Page: 1 of 8 Tag: 25T RTU-2, 25T RTU-2-1 T/�ANE® CQuantity: Customer: Project: Name: Kruger Medical Building Remodel VARIABLE FREQUENCY OUTDOORAIR [OUTDOORAIR LEVAPCOIL SUPPLYAIRSECTION DRIVE OPTION SECTION DAMPERS RETURN AIR EXHAUST SECTION DAMPERS ILTER SECTION EXTENDED CASING / HEAT SECTION EXHAUST S I II • �I I ECTION FILTER / EVAP SECTION SUPPLYAIR SECTION EXTENDED CASING / .• ' HEAT SECTION 20 - 30 TON COOLING EXTENDED CASING TYPICAL LAYOUT DIMENSION DRAWING Created: 1/9/2024 Page: 2 of 8 Created: 1/9/2024 Page: 2 of 8 Tag: 25T RTU-2, 25T RTU-2-1 Quantity: 2 Customer: Project: Name: Kruger Medical Building Remodel 43 PANEL C 40 11/16" 44 PANEL T--I F— — — —� I I I 4011/16" ' ' � SUPPLY � I I I I 25 12" NOTES: 1. FOR HORIZONTAL DISCHARGE ON SFHM, SLHM AND SSHM UNITS, ONLY THE PANEL B CAN BE REMOVED. PANELACANNOT BE USED DUE TO THE LOCATION OF THE HEATING 2. ADD AN EXTRA 0.20 - INCHES PRESSURE DROP TO THE SUPPLY EXTERNAL STATIC ACCOUNT FOR THE EXTRATURN THE AIR IS MAKING. 1 THE OPENINGSALL HAVEA1.25-INCH LIPAROUND THE PERIMETER TO FACILITATE DUCTWORK ATTACHMENT 4_ IF EXHAUSTIRETURN FANS ARE BEING USED, PROVISION SHOULD BE MADE FOR ACCESS TO THE EXHAUST COMPONENTS ,SINCE THE ACCESS DOOR IS NOW BEING USED AS RETURN 5. USE THE DIMENSION PROVIDED AND THE SUPPLY CFM TO CALCULATE THE VELOCITY (FT/MIN) THOUGHT THE OPENINGS TO BE SURE THEY ARE ACCEPTABLE COILS. 25TON HORIZONTAL DISCHARGE PANEL DIMENSION DRAWING Created: 1/9/2024 Page: 3 of 8 Tag: 25T RTU-2, 25T RTU-2-1 T/�ANE® CQuantity: Customer: Project: Name: Kruger Medical Building Remodel NOTES: 1. VERIFY WEIGHT, CONNECTION, AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 25 TON POWER AND CONTROL OPENINGS DIMENSION DRAWING Created: 1/9/2024 Page: 4 of 8 Tag: 25T RTU-2, 25T RTU-2-1 T/�ANE® CQuantity: Customer: Project: Name: Kruger Medical Building Remodel 1" 5/8" 112" 5 8" y 1" 3" 90° 5 5/8" 3 5/8" 111 " �--2 3/4"30' 1 5/8" 5/8" 9/16" 13116" _ 5 13/16" TYPICAL PEDESTAL AND BASE DIMENSION DRAWING UNIT BASE 2 1/2" LIFTING LUG SHIPS WITH CURB �4" LONG FIELD INSTALLED GASKET 3" 2 1/2"- LIFTING LUG 4" LONG 3/8" 3" PEDESTAL 2" X 4" NAILER (FURNISHED WITH KIT) ROOF CURB TYPICAL PEDESTALAND BASE PAN DETAIL TYPICAL ROOF CURBAND BASE PAN DETAIL DETAIL DETAIL Created: 1/9/2024 Page: 5 of 8 Tag: 25T RTU-2, 25T RTU-2-1 Quantity: 2 Customer: Project: Name: Kruger Medical Building Remodel Center of Gravity X:13.54It Notes: Center of Gravity Y. 3.88 ft 1. The actual weight is stamped on the unit nameplate. Point Load 1: 6202 lb 2. The weight shown represents the typical Point Load 2: 655.9 Ib unit operating weight for the configuration Point Load 3: 685.4 Ib selected. Estimated at +/- 10% of the Point Load 4: 7212 lb nameplate weight- . Point Load 5: 740.9 lb 3. Design Special weights are not displayed. 0,0 Point Load 6: 776.6 lb Any weight added through COD (Custom Point Load 7: 762.1 lb Order Design) Point Load 8: 797 8 lb will not be accounted in the +/- 10% estimate 0 4. When 2 or more units are to be placed side by Total Weight: 5,760.0lb side, the distance between the units should be increased to 150% of the recommended single Point load X location 1: 0.33 ft unit clearance. The units should also be Point load X location 2: 10.33 ft staggered to reduce span deflection & assure Point load X location 3: 18.83 ft proper diffusion of exhaust air. Point load X location 4: 22.08 ft Point load X location 5: N/A Point load Y location 1: 0.33 ft Point load Y location 2: 7.25 ft PL 2, X1 PI-4 X2 PL 6, X 3 PL 8 X4 PL3.X2 PL5,X3 PL7.X4 CENTER OF GRAVITY AND INSTALL WEIGHT X-Y POINTS AIR COOLED DRAWING Created: 1/9/2024 Page: 6 of 8 Tag: 25T RTU-2, 25T RTU-2-1 T/�ANE® CQuantity: Customer: Project: Name: Kruger Medical Building Remodel 72" 96" Note: When 2 or more units are to be placed side by side, the distance between the units should be increased to 150% of the recommended single unit clearance. The units should also be staggered to reduce span deflection & assure proper diffusion of exhaust air. CLEARANCE CENTER OF GRAVITY AND INSTALL WEIGHT X-Y POINTS AIR COOLED DRAWING 96" 96" CLEARANCE Created: 1/9/2024 Page: 7 of 8 Tag: 25T RTU-2, 25T RTU-2-1 T/�ANE® CQuantity: Customer: Project: Name: Kruger Medical Building Remodel CUSTOMER CONNECTION WIRE RANGE NOTES: COMPONENT TYPE/SIZE WIRE OTY PER PHASE WIRE RANGE 510ATERMINALBLOCK 2 6AWG-250kemI TERMINAL BLOCKAND STD SCCR DISCONNECT SWITCH SIZES ARE 760ATERMINAL BLOCK 2 4 AWG -500 kcmil CALCULATED BY SELECTING THE SIZE GREATER THAN OR EQUAL TO 1.15 X (SUM OF UNIT LOADS). 150ADISCONNECT SWITCH (STD SCCR) 1 14AWG -30AWG 250A DISCONNECT SWITCH (STD SCCR) 1 3/0AWG - 350 kcmil SEE UNIT LITERATURE FOR UNIT LOAD VALUES. 400ADISCONNECT SWITCH (STD SCCR) 2 2/0AWG -500 kcmil 600ADISCONNECT SWITCH (STD SCCR) 2 2/0AWG -500 kcmil HIGH SCCR DISCONNECT SWITCH SIZESARE CALCULATED BY SELECTING 150ADISCONNECT SWITCH (HIGH SCCR) 1 14AWG-3)OAWG 250A DISCONNECT SWITCH (HIGH SCCR) 1 3/0AWG - 350 kcmil THE SIZE GREATER THAN OR EQUAL TO 1.25 X (SUM OF UNIT LOADS). 400ADISCONNECT SWITCH (HIGH SCCR) 2 2/0AWG -500 kcmil SEE UNIT LITERATURE FOR UNIT LOAD VALUES. 600ADISCONNECT SWITCH (HIGH SCCR) 2 2/0AWG -500 kcmil `250A DISCONNECT SWITCHES CAN ACCOMMODATE 4AWG - 4/0AWG IF LUG SCREWS ARE CHANGED TO S1A59551 KIT (PROVIDED WITH UNIT) Created: 1/9/2024 Page: 8 of 8