Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED BLD FIR BLD2024-0598+Architectural_Plan+5.3.2024_4.42.02_PM+4236964
ABBREVIATIONS A/C AIR CONDITIONING ACT ACOUSTICAL CEILING TILE ADJ ADJUSTABLE AFF ABOVE FINISHED FLOOR AMP AMPERE ARCH ARCHITECT BOH BACK OF HOUSE CAB CABINET CL CENTER LINE CLG CEILING CM STARBUCKS CONSTRUCTION MANAGER CTR CENTER CX COMMISSIONING CXA COMMISSIONING AGENT DEG DEGREE DET DETAIL DIA DIAMETER DIM DIMENSION DM STARBUCKS DESIGN MANAGER DN DOWN EA EACH EL ELEVATION EQ EQUAL EXIST EXISTING EXT EXTERIOR FF&E FURNITURE, FIXTURE, AND EQUIPMENT FLR FLOOR FOH FRONT OF HOUSE FOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FOIO FURNISHED BY OWNER INSTALLED BY OWNER FT FOOT/FEET G GROUND GC GENERAL CONTRACTOR GWB GYPSUM WALLBOARD HC HOLLOW CORE HDW HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR HT HEIGHT HVAC HEATING, VENTILATING AND AIR CONDITIONING I.D. INSIDE DIAMETER LEED LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGN LL LANDLORD LV LOW VOLTAGE MAX MAXIMUM MEP "MECHANICAL, ELECTRICAL AND PLUMBING" MFR MANUFACTURER MIN MINIMUM NIC NOT IN CONTRACT NL NIGHT LIGHT NTS NOT TO SCALE OC ON CENTER O.D. OUTSIDE DIAMETER PIR PASSIVE INFRARED SENSOR PLC PLACE R RADIUS REF REFERENCE REQ'D REQUIRED REV REVISION RND ROUND SB STARBUCKS SC SOLID CORE SF SQUAREFEET SHT SHEET SIM SIMILAR SPEC SPECIFICATION SQ SQUARE TEMP TEMPORARY TYP TYPICAL UC UNDER COUNTER UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD RESPONSIBILITY LEGEND GC GENERAL CONTRACTOR LL LANDLORD SB STARBUCKS SV SIGNAGE VENDOR ARCHITECTURAL SYMBOL LEGEND N NORTH ARROW SECTION CALL -OUT A REVISION TAG 0 2 4 8 Scale: X =X GRAPHIC DATUM EXTERIOR INTERIOR SCALE POINT ELEVATION ELEVATION CALL -OUT CALL -OUT --- XX XXXX AFF X' XX" DETAIL SHEET ABOVE FINISH FINISH FACE TO REVISION CALL -OUT NOTE FLOOR FINISH FACE CLOUD CALLOUT HEIGHT TAG DIMENSION T XXXXX X XXXXX D XXXXX XX W XXXXX PAINT DESIGN ID DOOR WINDOW TAG TAG TAG TAG r Z . 1ATIft VICINITY PLAN ,f nla h Park O Edmonds Main st Dayton St ,04 - fonds 3rsh dinonds n City Park N Walnut St n Main St PINE PARK NEIGHBORHOOD Fp 2201h St SW N > D Woodway i 0 226th St SW v_ y � a Taco B 1 ®Great Clips �ATe \th St SW 0 eta INTERIOR WALL TAG PROJECT CONTACTS MAILING STARBUCKS COFFEE COMPANY ADDRESS: 2401 UTAH AVENUE SOUTH MS STOP: S-SD10 SEATTLE, WASHINGTON 98134 (206) 318-1575 DESIGN RACHEL ABBOTT MANAGER: GRAPHITE DESIGN GROUP 1809 SEVENTH AVENUE STE 700 SEATTLE, WA 98101 RACHEL.ABBOTT@GRAPHITEDESIGNGROUP.COM CONSTRUCTION ANDREW OUDERKIRK MANAGER: WILCOX CONSTRUCTION LLC 234 5TH AVE SOUTH EDMONDS, WA 98020 AOU DERKIRK@W ILCOXCONSTRUCTION.COM LANDLORD: RANDALL KESSLER KESSLER & KESSLER LLC REK@KESSLERKESSLER.COM ARCHITECT GRAPHITE DESIGN GROUP, LLC OF RECORD: 1809 SEVENTH AVENUE STE 700 SEATTLE, WA 98101 (206) 224-3335 MEP SCHNACKEL ENGINEERS, INC. CONSULTANT 127 W 30TH STREET 9TH FLOOR OF RECORD: NEW YORK, NY 10001 (212) 366-4813 STRUCTURAL AU ENGINEERING CONSULTANT: 13228 NE 20TH ST #100 BELLEVUE, WA 98005 (212) 203-4574 Approved roved x DFM Okras Burt ' yk� South County Fire Date: 05/22/2024 44, ii61► 22-2024 AN REVIEW )TES: APPROVED =M BURT SCOPE OF WORK �'W TENANT IMPROVEMENT OF AN EXISTING STARBUCKS CAFE WITH DRIVE- AllTHRU IN A EXISTING MULTI -TENANT OR SINGLE TENANT COMMERCIAL �.� SHELL SPACE. INTERIOR SCOPE TO INCLUDE: -REDESIGN OF CAFE, ENGINE, AND BACK OF HOUSE -NEW ENGINE EQUIPMENT AND FINISHES -NEW CEILINGS --'� EXTERIOR SCOPE TO INCLUDE: -NEW DRIVE-THRU EQUIPMENT -NEW WAYFINDING GRAPHICS Edmonds-Woodway0 -NEW PATIO BENCH High School WinC( 226th St SW � v Hanoi Esperance 2281hStSW 1 f o y n SHERWOOD WhIfIyB21. ` FOREST 238th StSW 3 A AGE 1 2,"th St SW 2,"th St SW Kruckeberg Botanic Garden Costco Wholesal N zoom sr ALL WORK SUBJECT A PROV TO FIELD INSPECTION FOR LANS MUST CODE COMPLIANCE le%m ITC SEPARATE SUBMITTALS -EXTERIOR SIGNAGE GENERAL NOTES 1. THE DRAWINGS AND PROJECT MANUAL TOGETHER CONSTITUTE THE CONTRACT DOCUMENTS FOR CONSTRUCTION. ALL GENERAL REQUIREMENTS ARE TO BE MET AND ALL MATERIALS, FINISHES AND SYSTEMS ARE TO BE INSTALLED AND PERFORM PER SPECIFICATIONS UNLESS OTHERWISE NOTED. 2. GENERAL CONTRACTOR SHALL VISIT THE SITE, REVIEW THE BUILDING SHELL DRAWINGS AS SUBMITTED BY THE LANDLORD OR STARBUCKS AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO CONSTRUCTION. 3. GENERAL CONTRACTOR SHALL CONSULT WITH STARBUCKS CONSTRUCTION MANAGER TO RESOLVE ANY CHANGES, OMISSIONS OR PLAN DISCREPANCIES PRIOR TO CONSTRUCTION. 4. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH LOCAL, COUNTY, STATE AND FEDERAL CODES AND ORDINANCES. 5. GENERAL CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES. 6. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES REQUIRED BY OTHER TRADES AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. DO NOT SCALE DRAWINGS. 7. GENERAL CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS, OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF THE WORK. 8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING PERMITS FOR FIRE PROTECTION, PLUMBING, MECHANICAL, AND ELECTRICAL SYSTEMS PRIOR TO INSTALLATION OF SUCH SYSTEMS. 9. GENERAL CONTRACTOR SHALL RETAIN ONE SET OF PERMIT PLANS ON -SITE TO DOCUMENT ALL CHANGES MADE DURING CONSTRUCTION. THE RECORD DRAWINGS SHALL BE ISSUED TO THE OWNER AT PROJECT CLOSE-OUT AS DESCRIBED IN THE GENERAL REQUIREMENTS OF THE PROJECT MANUAL. 10. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING DELIVERY OF MATERIALS FROM STARBUCKS CONTRACTED THIRD PARTY LOGISTICS DISTRIBUTION SERVICES AND VENDOR DIRECT SHIPMENTS. SEE THE PROJECT MANUAL FOR ADDITIONAL INFORMATION. 11. RESPONSIBILITY FOR SUPPLY AND DELIVERY OF MATERIALS AND EQUIPMENT IS IDENTIFIED IN THE DRAWING SCHEDULE SHEETS UNDER THE COLUMN LABELED "RESPONSIBILITY". 12. FOR THE PURPOSE OF THE DOCUMENTS, TO "INSTALL", SHALL MEAN TO PROVIDE ALL FASTENERS, MISCELLANEOUS HARDWARE, BLOCKING, ELECTRICAL CONNECTIONS, PLUMBING CONNECTIONS AND OTHER ITEMS REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION, UNLESS OTHERWISE NOTED. 13. ALL ITEM SUBSTITUTIONS MUST BE APPROVED BY THE STARBUCKS CONSTRUCTION MANAGER. SITE INFORMATION CODE AUTHORITIES: BUILDING CODE: PLUMBING CODE: MECHANICAL CODE: ELECTRICAL CODE: ENERGY CODE: FIRE CODE: HEALTH CODE: ACCESSIBILITY CODE: ZONING: PARCEL NUMBER: LEASABLE AREA: CONSTRUCTION TYPE PROPOSED USE: 2021 INTERNATIONAL BUILDING CODE 2021 UNIFORM PLUMBING CODE 2021 INTERNATIONAL MECHANICAL CODE 2020 NATIONAL ELECTRICAL CODE 2021 WA STATE ENERGY CODE 2021 INTERNATIONAL FIRE CODE WA RETAIL FOOD CODE 2017 ICC/ANSI 117.1 W/ WAC AMENDMENTS 27033600118400 1,792 SF V-B RETAIL SALES AND SERVICES BUILDING INFORMATION OCCUPANCY TYPE: A-2 BUILDING AREA: 1,792 SF TENANT AREA: 1,792 SF BUILDING CLASSIFICATION: V-B FIRE SPRINKLER: NON -SPRINKLED INDEX OF SHEETS LEGEND: X - SHEET ISSUED R - SHEET ISSUED FOR REFERENCE AND COORDINATION ONLY SEE TITLEBLOCK FOR REVISION ISSUE DATE(S) Lu W NM I W 0 0 0 0 Lu Fn Fn Fn cn Lu w w w w SHEET SHEET TITLE m a R R R R GENERAL G001 IGENERAL INFORMATION X G002 I LIFE SAFETY AND ACCESSIBILITY PLAN X G003 IRENDERINGS X DEMOLITION D101 DEMOLITION SITE PLAN X D102 DEMOLITION FLOOR PLAN X D103 DEMO REFLECTED CEILING PLAN X D104 DEMO ROOF PLAN X D201 DEMO EXTERIOR ELEVATIONS X ARCHITECTURAL A001 ARCHITECTURAL SITE PLAN X A002 ARCHITECTURAL SITE DETAILS X A003 ARCHITECTURAL SITE DETAILS X A101 BUILDING FLOOR PLAN X A102 BUILDING FLOOR PENETRATION PLAN X A103 ROOF PLAN X A201 BUILDING EXTERIOR ELEVATIONS X A202 BUILDING EXTERIOR ELEVATIONS X A301 PATIO BENCH DETAILS X A501 BUILDING DETAILS X A602 WINDOW AND DOOR SCHEDULES & DETAILS X INTERIORS 1101 FF & E PLAN X 1102 ENLARGED FF & E PLAN X 1103 CASEWORK PLAN X 1104 REFLECTED CEILING PLAN X 1105 REFLECTED CEILING PLAN - LIGHTING X 1106 FLOOR FINISH PLAN X 1107 WALL FINISH PLAN X 1201 INTERIOR FINISH ELEVATIONS X 1202 INTERIOR FINISH ELEVATIONS X 1203 INTERIOR FINISH ELEVATIONS X 1204 INTERIOR FINISH ELEVATIONS X 1205 INTERIOR FINISH ELEVATIONS X 1401 RESTROOM PLAN & ELEVATIONS X 1501 INTERIOR DETAILS - FLOORS X 1502 INTERIOR DETAILS - WALL X 1503 INTERIOR DETAILS - WALL X 1504 INTERIOR DETAILS - WALLS & CEILING X 1505 INTERIOR DETAILS - SUSPENDED CEILING X 1506 INTERIOR DETAILS - CASEWORK X 1601 CASEWORK AND FF&E SCHEDULES X 1602 INTERIOR FINISHES SCHEDULES X 1603 LIGHTING AND PLUMBING SCHEDULES X ELECTRICAL E001 ELECTRICAL LEGEND X E100 ELECTRICAL SITE PLAN X E101 POWER PLAN AND EQUIP SCHEDULES X E102 ENLARGED POWER AND SYSTEMS PLAN X E103 LIGHTING PLAN X E104 VENSTAR CONTROL DIAGRAM R E501 ELECTRICAL DETAILS X E502 ELECTRICAL DETAILS X E503 ELECTRICAL DETAILS X E504 ELECTRICAL DETAILS X E601 PANEL SCHEDULES AND ONE -LINE DIAGRAM X If•IxyN/_ 01ley—Al I M101 MECHANICAL DESIGN PLAN X M501 MECHANICAL DETAILS X M601 MECHANICAL DETAILS X M701 MECHANICAL DETAILS X PLUMBING P100 PLUMBING SCHEDULES X P101 PLUMBING SUPPLY PLAN X P102 PLUMBING WASTE & VENT PLAN X P201 PLUMBING DETAILS X P202 PLUMBING DETAILS X P203 PLUMBING DETAILS X P301 PLUMBING RISER DIAGRAM X P302 PLUMBING RISER DIAGRAM X City Of Edmonds IIV I LI\IVI\/-119V L/\I LI\IVI\ 1\LIVIV VLL -------------------------------------------------- ------------------------------------------------------------ Address ' 9801 EDMONDS WAY Owner STARBUCKS Approved Date 06/03/2024 r- — A — --I— -- 1 cllln� I�ulllucl bLUZUZ4-UWJt5 Separate permits required Plumbing Mechanical STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !jaGRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 PM i REG MARTIN LEE HILL ITE Of WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT C) W Q W Q ��^^ V J U) 0 w 0 O 2i Z 0' 0 z0 Qoo U U w O LU LU r �O�y'� 0 N 0. d N 0. KJ d 0) w STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: GENERAL INFORMATION SCALE: AS SHOWN SHEET NUMBER: 0001 INDOOR SEATING CALCULATIONS DESCRIPTION NUMBER OF ITEMS SEATS TABLE TOP, ROUND 2 4 TABLE TOPS AT BANQUETTE 3 6 SIT -HERE COUNTER SEAT 7 7 LOUNGE CHAIR 4 4 TOTAL 21 TOTAL ACCESSIBLE SEAT (>_5%) 2 EGRESS CALCULATIONS EXIT WIDTH REQUIRED - 75 OCC. x 0.2 = 15 IN. EXIT WIDTH PROVIDED = 68 IN. EXITS = 34 IN. PRIMARY ENTRY, 34 IN. SECONDARY ENTRY NUMBER OF EXITS REQUIRED = 2 NUMBER OF EXITS PROVIDED = 2 MAXIMUM. ALLOWABLE TRAVEL... = 200'- 0" MAXIMUM. TRAVEL DISTANCE PROVIDED = 75'- 2" MINIMUM. EXIT SEPARATION = 89' - 10" (MAXIMUM DIAGONAL) / 2 = 44' - 11" EXIT SEPARATION PROVIDED = 49' - 10" PLUMBING FIXTURE CALCULATIONS CHAPTER29-2018 IBC TABLE 2902.1 OCCUPANCY MALE FEMALE TOTAL 25 OCC. 25 OCC. 75 OCC. WATER CLOSETS URINALS* LAVATORY WATER FOUNTAIN** FIXTURES 1 PER 75 1 PER 200 1 PER 100 OR STATION REQUIRED 1 M 1 F 0 M 1 M 1 F 0 PROVIDED 1 M 1 F 0 M 1 M 1 F 0 *IN EACH BATHROOM OR TOILET ROOM, URINALS SHALL NOT BE SUBSTITUTED FOR MORE THAN 67% OF THE REQUIRED WATER CLOSETS IN ASSEMBLY OCCUPANCIES. **RETAIL ESTABLISHMENT SERVES WATER UPON REQUEST. OCCUPANCY CALCULATIONS (INTERIOR) LOAD FACTOR NAME AREA CLASSIFICATION (PER /SF) OCCUPANTS LOCATION INTERIOR (E) 58 SF ACCESSORY 0 0 INTERIOR RESTROOM 1 (E) 47 SF ACCESSORY 0 0 INTERIOR RESTROOM2 CAFE 591 SF UNCONCENTRATED TABLES 15 40 INTERIOR AND CHAIRS ENGINE 262 SF KITCHEN, COMMERCIAL 200 2 INTERIOR QUEUING 123 SF ASSEMBLY STANDING 5 25 INTERIOR SPACE VESTIBULE 28 SF ACCESSORY 5 6 INTERIOR WORKROOM 411 SF STORAGE, MERCANTILE 300 2 INTERIOR INTERIOR 1521 SF 75 TOTAL OCCUPANTS 1521 SF 75 COMBINED: Occupancy load shall be posted in a conspicuous location. POINT OF GREATEST REMOTENESS / I / I I I I � I EXIT TO GRADE REQD PROV NA NA 5.2" 34" 23 OCC OCCUPANCY (FIXED SEATING) NAME LENGTH CLASSIFICATION LOAD FACTOR (OCC/LF) OCCUPANTS FIXED SEATING 11' -10 1/4" �ASSEMBLYW/ FIXED SEATING 2'- 0" 6 TOTAL OCCUPANTS (FIXED SEATING) 6 6 HEALTH DEPT. FINISH SCHEDULE ENGINE FLOOR: POLYVINYL FLOORING WALL: WALL TILE, BACKSPLASH, WITH POLYVINYL BASE CEILING: GYPSUM CEILING CAFE FLOOR: TILE WALL: THIN BRICK, WALL COVERING, TILE BASE CEILING: GYPSUM, ACT, OTS WORKROOM FLOOR: POLYVINYL FLOORING WALL: FRP WITH POLYVINYL BASE CEILING: ACOUSTICAL CEILING TILE RESTROOM FLOOR: TILE WALL: PARTIAL HEIGHT TILE, GYPSUM, TILE BASE CEILING: GYPSUM CEILING HEALTH DEPT. PLAN NOTES A. GENERAL CONTRACTOR TO SCHEDULE WITH REFRIGERATION CONTRACTOR TO CONDUCT INITIAL FOOD CASE START-UP AND TESTING. FOR APPROVED CONTRACTOR, CONTACT THE VENDOR. B. THE SPACE IS SERVED BY THE MUNICIPAL WATER AND SEWER SYSTEM UNLESS OTHERWISE NOTED. C. ALL EQUIPMENT AND INSTALLATION WILL MEET NATIONAL SANITATION FOUNDATION STANDARDS OR EQUIVALENT. D. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS, EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE AS PLACES FOR ACCUMULATION OF DUST, DIRT AND DEBRIS E. WARMING OVEN(S) SHOWN FOR PERMITTING PURPOSES. INSTALLATION AT STORE OPENING TO BE VERIFIED BY STARBUCKS CONSTRUCTION REPRESENTATIVE. F. EACH HAND WASHING WILL HAVE A SINGLE SERVICE TOWEL AND SOAP DISPENSER AND ALL HAND SINKS TO HAVE A COMBINATION FAUCET OR PREMIXING FAUCET. G. REFERENCE INTERIOR SCHEDULE SHEETS (1600 SERIES) FOR ADDITIONAL INFORMATION. H. PROVIDE SNEEZE GUARDS WHERE REQUIRED BY JURISDICTION. 1. ALL FOOD STORAGE AND DISPLAY SHELVING SHALL BE A MINIMUM 6" (150MM) ABOVE FINISH FLOOR. KEYED NOTES 1. THRESHOLDS TO BE BARRIER FREE COMPLIANT PER ALL APPLICABLE CODES. 2. BARRIER -FREE PATH OF TRAVEL. 3. 30" (160 MM) X 48" (1220 MM) CLEAR FOR WHEELCHAIR ACCESS. 4. 60" (1525 EELCHAIR ACCESS. 67" diameter required per 2017 ANSI 5. 32" (815 MM) MINIMUM CLEAR AT RESTROOM DOOR. 6. POS TRANSACTION PLANE, CONDIMENT CART TOP AND HAND-OFF PLANE ARE 34 INCHES (860 MM) ABOVE THE FINISHED FLOOR FOR WHEELCHAIR ACCESSIBILITY. 7. PROVIDE BARRIER -FREE SIGNAGE AT ACCESSIBLE RESTROOMS PER ALL APPLICABLE CODES. 8. PROVIDE TACTILE "EXIT" SIGNAGE. 9. PROVIDE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN WHERE REQUIRED BY APPLICABLE LAWS OR CODES. 10. 3-COMPARTMENT SINK. 11. WALL MOUNTED HAND SINK. 12. WATER FILLIG STATION. 13. ICE MACHINE. 14. MOP SINK. 15. WATER FILTRATION SYSTEM. 16. HAND SINK. 17. DISHWASHER. LEGEND <-------- PATH OF TRAVEL COMMON PATH OF TRAVEL BARRIER (MIN 3'-0" FTRAVELREE PATH OF NO PINCH POINT) 27S EMERGENCY LIGHT EXIT SIGN FE _y FIRE EXTINGUISHER F-------� I I ADA ACCESSIBLE SEATING I 130" (915MM) X 48" (1220MM) CLEAR AREA I I L J I I I I -- t---] EXIT TO GRADE REQD PROV NA NA 5.2" 34" 23 OCC MEANS OF EGRESS NOTES A. EVERY ROOM OR SPACE THAT IS ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT ACCESS DOORWAY. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER AUTHORIZED AGENT. (1004.3) B. EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SIMILAR SPACES. (1014.2) C. PANIC AND FIRE EXIT HARDWARE, WHERE INSTALLED ON DOORS IN THIS BUILDING SHALL SATISFY THE FOLLOWING (1008.1.10): 1) THE ACTUATION PORTION OF THE RELEASING DEVICE SHALL EXTEND AT LEAST ONE-HALF OF THE DOOR LEAF WIDTH. 2) THE MAXIMUM UNLATCHING FORCE DOES NOT EXCEED 15 POUNDS (6.8 KG). 3) PIVOTED OR BALANCED DOORS SHALL BE OF THE PUSH -PAD TYPE WHERE PANIC HARDWARE IS REQUIRED AND THE PAD SHALL NOT EXTEND ACROSS MORE THAN ONE-HALF OF THE DOOR WIDTH, MEASURED FROM THE LATCH SIDE. 4) PANIC HARDWARE LISTED IN ACCORDANCE WITH UL 305. 5) FIRE EXIT HARDWARE LISTED IN ACCORDANCE WITH UL 10C AND UL 305. D. STRUCTURAL ELEMENTS, FIXTURES OR FURNISHINGS SHALL NOT PROJECT HORIZONTALLY FROM EITHER SIDE MORE THAN 4 INCHES (100 MM) OVER ANY WALKING SURFACE BETWEEN 27 INCHES (685 MM) AND 80 INCHES (2030 MM) ABOVE THE WALKING SURFACE. EXCEPTION: HANDRAILS SERVING STAIRS AND RAMPS ARE PERMITTED TO PROTRUDE 4 1/2 INCHES (115 MM) FROM THE WALL. (1003.3.3) E. THE PATH OF EGRESS TRAVEL EXITS AND WITHIN EXITS IN THIS BUILDING SHALL BE IDENTIFIED BY EXIT SIGNS CONFORMING TO THE REQUIREMENTS OF SECTION 1011 AND AS NOTED BELOW: 1) EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL. 2) EXIT SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY INDICATE THE DIRECTION OF EGRESS TRAVEL. 3) NO POINT IN A CORRIDOR SHALL BE MORE THAN 100 FT (30.5 M) OR THE LISTED VIEWING DISTANCE FOR THE SIGN, WHICHEVER IS LESS, FROM THE NEAREST VISIBLE EXIT SIGN. F. WHERE KEY OPERATED LOCKING DEVICES ARE USED, POST A SIGN ON OR ADJACENT TO THE REQUIRED MAIN EXIT DOOR WITH 1 INCH (25 MM) LETTERING STATING THAT "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED". (1008.1.9.3) G. EGRESS DOORS OR GATES SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT. DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES SHALL BE INSTALLED 34 INCHES (860 MM) TO 48 INCHES (1220 MM) ABOVE FINISHED FLOOR. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED. THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. (1008.1.9) H. LANDINGS SHALL BE PROVIDED ON EACH SIDE OF DOORS AND SUCH LANDING SHALL BE AT THE SAME ELEVATION ON EACH SIDE OF THE DOOR LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE DOOR AND LENGTH MEASURED IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 44 INCHES (11120 MM). (1008.1.5, 1008.1.6) EXIT TO GRADE REQD PROV NA NA 5.2" 34" 4 OCC STARBVCKS° 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !il GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 XREGISDI MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O Ir- 06 Q O co vJ Q �/ �./ ) W co Z LU O Z 0Y 07 0 z0 Qoo U U W O W � LU O 0- W 0 o_ rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: LIFE SAFETY AND ACCESSIBILITY PLAN SCALE: AS SHOWN 1 1 r- r- n A r- r- T\ / r% 1 A 1 SHEET NUMBER: 0002 NOTE: RENDERINGS ARE FOR ILLUSTRATION PURPOSES ONLY. FOR ANY DISCREPANCIES CD DRAWINGS SUPERSEDE. _0 1 ENGINE VIEW FROM ORDER PICK-UP 3. CAFE SEATING AT MAIN ENTRY 0 2. ENGINE VIEW FROM ORDER POINT 5! -I 1 L7 1 CAFE OVERVIEW STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !ja GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El 7MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 06 Q OM W rn c� Q w p LU O Z 0 Uj o z0 Qpo U U W O LU 0 LU O 000p aW a- rnW STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: RENDERINGS SCALE: AS SHOWN 5. PATIO SHEET NUMBER: 0003 10 D2 D3 . D2 O 3c �� IK </ID1 D4 FED_, I � � I ����������������������������������������������������������� � �� III °-••' �� LI IJ ° 14 ter, -7 IK </I D1 D9)-\ L �TTTTTTTTTTT�T�l��l�TTTTTTTTTTTT� d ° ° XC 3 9e" ° ° d STARBUCKS TENANT SPACE a T 1,785 SF _IL� ^� .. °' n � ° _ `I' \I, \I' `I, \I, `I' \I, \I' `I, \I' `I' \I, `I' `I, \I' `I, \I, `I' \I, \I' \I' `I' d �' - ✓ 4 °•-, - 'G r d - - °' _O - - - ° �• d'° _ ." -e °d - _ - - °-° - d°e _ i `I, `I' `I, `I' `I, `I, `I' `I, `I' `I, `I' `I, `I' `I, - •`I, `I' `I, `_I, `I'° `Ia, `I' `I,e .`Ia' �`,I' `I, `I' -`I,- `I'. `I, `I, `I'- `I, `I,II- `I' `I,° `Id,' `I' 8`I,_ `-I'�°`I:, `I' `I' ,`I, `I'• `I, `I•' `I'; `I, `;I' -`I, `I ..II- e ,aalI°' a`°I, `.I',, `I,, '`I,° `,I'a `I-, `I, `I`, `I' `I' `I,, `I'- `-I, `I . `I, `I, `I' `I,. �a`.I,' `-I, `I' •`I, `I'' `I, `I' `I' `I, `I' `I, `I' `I, `I, `I' `I, `�ITc' `I, `�I7c' `I, `�I7c' `I, `�ITc, `I, `�I7c' `I, `�ITc' `�ITc, `I, `�I7c' `I, `�I7c, °I EDMONDS WAY KEYED NOTES GENERAL NOTES 1. PRESERVE EXISTING CONDUITS AND CONCRETE A. IF DURING DEMOLITION CONDITIONS ARE REVEALED FOOTING FOR NEW SIGN. THAT MAY JEOPARDIZE INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT, GENERAL 2. PRESERVE EXISTING BIKE RACKS. CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY. 3. EXISTING GAS METER. B. GENERAL CONTRACTOR IS RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO DEMOLITION TO REVEAL FULL SCOPE OF WORK. NOTIFY STARBUCKS CONSTRUCTION ITEMS TO DEMOLISH MANAGER IF ING IONS DEVIATE FROM CONSTRUCTION DTOCUMEENTS D1. DIRECTIONAL ARROW GRAPHIC C. DEMOLITION PLANS REPRESENT APPROXIMATE D2. (2) DRIVE-THRU DIRECTIONAL SIGNAGE LOCATION OF ITEMS TO BE DEMOLISHED. PRIOR TO D3. DRIVE-THRU DIRECTIONAL EXIT SIGNAGE DEMOLITION, FIELD VERIFY THAT ITEMS TO BE D4. DRIVE-THRU ORDER POINT GRAPHIC DEMOLISHED DO NOT PROVIDE SUPPORT FOR EXISTING D5. FREESTANDING ORDER POINT WITH CANOPY BUILDING ELEMENTS AND EXISTING CONSTRUCTION TO D6. 5-PANEL DRIVE-THRU MENU REMAIN. NOTIFY STARBUCKS CONSTRUCTION D7. PRE -MENU BOARD MANAGER IF DEMOLITION WALLS SUPPORT EXISTING D8. SIDEWALK MARKERBOARD BUILDING ELEMENTS. D9. PATIO GUARDRAIL, SEE PATIO DEMO SCOPE ON DEMO PLAN D. VERIFY WITH STARBUCKS CONSTRUCTION MANAGER ACCESS TO THE DEMOLITION AREA, INGRESS AND EGRESS ROUTES FOR MATERIAL AND EQUIPMENT. E. PROTECT EXISTING DRIVE-THRU EQUIPMENT, BOLLARDS, AND CURBS TO REMAIN ALONG WORK ACCESS ROUTES. F. CONTAIN DUST AND DEBRIS WITHIN THE DEMOLITION AREA. G. THE GENERAL CONTRACTOR SHALL PERFORM WORK IN A MANNER THAT DOES NOT DAMAGE THE EXISTING STRUCTURE. DEMOLITION SHALL NOT COMPROMISE THE STRUCTURAL INTEGRITY OF ANY WALLS, FLOORS, CEILINGS, SUPPORTS, STRUCTURE, ETC. TO REMAIN. H. ALL DEMOLITION MATERIALS AND DEBRIS SHALL BE DISPOSED OF ACCORDING TO FEDERAL, STATE AND LOCAL REGULATIONS. LEGEND ITEM TO BE DEMOLISHED 0 EXISTING ITEM TO REMAIN EXISTING LANDSCAPE AREA EXISTING CONCRETE WALKWAY AND CURB STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !ja GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 1 SPACE RESERVED OR ARCHITECT OF RECORD STAMP RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 06 Qo Q 00 vJ Q �/ �./ ) w 0 LLI O 2 Z Ir U) 0 z0 Qoo U � U w O W 0 LU r L 5 :) 0 0- w tY 00 a a) LLJ STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: DEMOLITION SITE PLAN DEMOLITION SITE PLAN scale: 1 " = 10'-0" SCALE: AS SHOWN SHEET NUMBER: D101 ITEMS TO PRESERVE CAFE P1. FIRE EXTINGUISHER P2. HIGH CHAIR P3. RECYCLE/WASTE BIN P4. GRAB BARS / BATHROOM ACCESSORIES P5. RESTROOM LAVATORY & WC P6. (1) ROUND TABLE AND BASE ENGINE P10. (2) MASTERENA II ESPRESSO MACHINE P11. (5) CUP LABELER P12. MOBILE CUP DISPENSER CADDY P13 (7) UNDERCOUNTER FRIDGE (27") P14. (4) POS PRINTER P15. UNDERCOUNTER SAFE AND BASE P16. (6) POS BANK P17. PASTRY TRAY CART P18. ZEPHYR CASE P19. (1) GRINDER P20. (2) EIKON OVEN P21. DT COMMUNICATION, TIMER, TENDERING REGISTER, MONITORS, EXPEDITER, AND TRIPLE MOUNTING ARM P22. POS REGISTER P23. (2) BLENDER BACK OF HOUSE P30. SINGLE DOOR FRIDGE P31. SINGLE DOOR FREEZER P32. ALL WORKROOM METRO RACKS UNO P33. TRASH TOTE P34. TWO DOOR FRIDGE P35. TWO DOOR FREEZER P36. ROLLING PASTRY TRAY P37. MONEY COUNTER P38. AV SYSTEM P39. 3 COMPARTMENT SINK P40. DISHWASHER P41. ICE BIN P42. WALL MOUNTED SINK, FAUCET, SOAP AND PAPER TOWEL DISPENSER P43. (1) OFFICE CHAIR DEMOLITION PLAN scale: 1 /4" = V-0" ITEMS TO DEMOLISH CAFE D1. (22) METAL FRAME CAFE CHAIR D2. (7) ROUND TABLE AND BASE D3. (6) LOUNGE CHAIR D4. (2) SQUARE COFFEE TABLE D5. (6) CAFE STOOL D6. (3) MERCH BAY UNIT D7. COMMUNITY TABLE AND LEGS D8. BAR HEIGHT COUNTER AND LEGS D9. BAR HEIGHT TABLE AND LEGS D10. CONDIMENT CART D11. WALK -OFF MAT D12. CHILLED FOOD CASE D13. PACKAGED FOOD CUBBY ENGINE D20. ALL ENGINE CASEWORK UNO D21. ALL ENGINE WORK SINKS UNO D22. ALL ENGINE EQUIPMENT UNO D23. ALL ENGINE FLOOR MATS RESTROOM D30. PAPER TOWEL DISPENSER WORKROOM D40. MANAGER'S STATION AND CHAIR WITH ALL ASSOCIATED EQUIPMENT, RA TO ANNOTATE, WE HAVE A MORE DETAILED NOTE IN OTHER PROJECTS D41. STORAGE LOCKER D42. COAT HOOK D43. OFFICE CHAIRS D44. DATA EQUIPMENT RACK D45. ICE MACHINE D46. ACCESSIBLE TABLE PATIO D50. (2) UMBRELLA AND BASE D51. (14) PATIO CHAIRS D52. (4) PATIO ROUND TABLETOP + BASE D53. ACCESSIBLE PATIO TABLE KEYED NOTES 1. EXISTING TO REMAIN (ETR). 2. REMOVE PORTION OF EXISTING WALL AS SHOWN. 3. REMOVE INTERIOR PARTITION FROM FLOOR TO UNDERSIDE OF STRUCTURE. 4. REMOVE EXISTING CASE WORK, HANGING DEVICES, AND FASTENERS AS SHOWN. REMOVE ASSOCIATED ELECTRICAL AND DATA LINES, CAP EXISTING PLUMBING. 5. REMOVE EXISTING FIXTURES, FURNITURE, AND EQUIPMENT. REFERENCE SCHEDULES FOR ITEMS TO BE PRESERVED. 6. EXISTING ELECTRICAL PANELS TO REMAIN AS -IS. MAINTAIN REQUIRED CLEAR SPACE AT FRONT OF PANELS. 7. REMOVE EXISTING WALL FINISHES AND PREP WALLS FOR NEW FINISHES AS INDICATED ON WALL FINISH PLAN. 8. REMOVE EXISTING FLOOR FINISHES AND PREP FLOOR FOR NEW FINISH AS INDICATED ON FLOOR FINISH PLAN 9. REMOVE PATIO RAILING. PATCH AND REPAIR EXISTING CONCRETE. 10. EXISTING ROOF LADDER TO REMAIN. 11. MOP SINK AND WATER FILTER SYSTEM TO REMAIN. LEGEND ITEM TO BE DEMOLISHED r PRESERVE FOR FUTURE USE L L GENERAL NOTES A. IF DURING DEMOLITION CONDITIONS ARE REVEALED THAT MAY JEOPARDIZE INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT, GENERAL CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY. B. GENERAL CONTRACTOR IS RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO DEMOLITION TO REVEAL FULL SCOPE OF WORK. NOTIFY STARBUCKS CONSTRUCTION MANAGER IF EXISTING CONDITIONS DEVIATE FROM CONSTRUCTION DOCUMENTS. C. REMOVE EXISTING INTERIOR WALL FINISH AS SHOWN. PATCH, REPAIR AND PREP. SUBSTRATE TO RECEIVE NEW FINISH. REMOVE WALL COVERINGS ON EXISTING WALLS TO REMAIN THAT FACE AREAS OF DEMOLITION. REMOVAL J. THE GENERAL CONTRACTOR SHALL PERFORM WORK IN A MANNER THAT DOES NOT DAMAGE THE EXISTING STRUCTURE. DEMOLITION SHALL NOT COMPROMISE THE STRUCTURAL INTEGRITY OF ANY WALLS, FLOORS, CEILINGS, SUPPORTS, STRUCTURE, ETC. TO REMAIN. K. ALL DEMOLITION MATERIALS AND DEBRIS SHALL BE DISPOSED OF ACCORDING TO FEDERAL, STATE AND LOCAL REGULATIONS. L. AT LOCATIONS WHERE EXISTING WALLS ARE TO BE REMOVED NEAR EXISTING WALLS TO REMAIN, PERFORM DEMOLITION WITHOUT DISTURBING EXISTING ELEMENTS TO REMAIN. WALLS TO REMAIN SHALL BE INTACT AND HAVE A NEAT SURFACE. SHALL INCLUDE ANY RESIDUAL MATERIAL AFTER M. REFER TO "ITEMS TO BE PRESERVED" LIST FOR ITEMS THAT DEMOLITION, (I.E. PIECES OF WALL COVERING OR BACKING). SHALL BE SALVAGED FOR RELOCATION. VERIFY WITH REMOVAL OF ALL COVERINGS IS TO BE DONE W/O OWNER FOR ON SITE STORAGE LOCATION OF SALVAGED DAMAGING THE EXISTING WALL SURFACE TO REMAIN. ALSO ITEMS. REMOVE WALL DEVICES AND ITEMS MOUNTED TO WALLS. N. DAMAGED FIREPROOFING SHALL BE REPAIRED/REPLACED D. REMOVE EXISTING FLOORING AS SHOWN. PATCH, REPAIR TO MATCH EXISTING. AND PREP. SUBSTRATE TO RECEIVE NEW FINISH. REMOVAL OF EXISTING FLOORING INCLUDES, BUT IS NOT LIMITED TO O. THE GENERAL CONTRACTOR SHALL DEMOLISH ANY EXISTING REMOVAL OF EXISTING CERAMIC TILE, CARPET OR VINYL ABANDONED VOICE/DATA CABLING AND DEAD OR NON-USE TILE FLOORING AND ASSOCIATED WALL BASE. SUBFLOOR TO ELECTRICAL BACK TO PANEL. ALL RECEPTACLES NOT BE STRIPPED OF ALL COVERING/FINISH AND CLEANED TO REUSED ARE TO BE REMOVED, PATCHED AND PAINTED. REMOVE EXISTING ADHESIVE, GROUT, MORTAR, DIRT AND COATINGS. FINAL SURFACE TO BE STREAK -FREE WITH NO P. REMOVAL OF LOW VOLTAGE EQUIPMENT, PERTAINING TO MACHINE MARKS AND/OR SMOOTH, STABLE AND LEVEL. DATA/COMMUNICATIONS AND TELEPHONE SHALL BE PROVIDE LEVELING WHERE NECESSARY TO ACCOMMODATE VERIFIED BY THE STARBUCKS CONSTRUCTION MANAGER NEW FINISHES. PRIOR TO REMOVAL. SALVAGED EQUIPMENT SHALL BE STORED IN A CLIMATE CONTROLLED ENVIRONMENT FOR E. DEMOLITION PLANS REPRESENT APPROXIMATE LOCATION FUTURE INSTALLATION. OF EXISTING WALLS TO BE DEMOLISHED. FIELD VERIFY TYPE OF CONSTRUCTION AND HEIGHT OF WALLS. PLANS DO NOT Q. LABEL ALL ITEMS AND PROPERLY STORE FOR RE -INSTALL. NECESSARILY INDICATE ALL DEMO WALLS, COUNTERS, HANDRAILS, WALL PROTECTION, CLOSETS, SINKS ETC. R. REMOVE EXISTING PLUMBING FIXTURES AND HVAC PRIOR TO DEMOLITION, FIELD VERIFY THAT WALLS TO BE EQUIPMENT AS NECESSARY. CAP LINES AND TERMINATE REMOVED DO NOT PROVIDE SUPPORT FOR EXISTING DUCTS AS NECESSARY FOR THOSE NOT BEING RE -USED. BUILDING ELEMENTS AND EXISTING CONSTRUCTION TO REMAIN. NOTIFY STARBUCKS CONSTRUCTION MANAGER IF DEMOLITION WALLS SUPPORT EXISTING BUILDING ELEMENTS. F. DEMOLISH AND REMOVE DOORS, VINYL BASE, CONDUIT, WIRING, DUPLEXES, DATA OUTLETS, CABLES, SHELVING, METAL STUD AND GYPSUM BOARD WALLS, CLOSETS, CABINETS, FILES, COUNTERS, WOOD MOLDING, SHELVES AND ENCLOSURES WHERE APPLICABLE. G. VERIFY WITH STARBUCKS CONSTRUCTION MANAGER ACCESS TO THE DEMOLITION AREA, INGRESS AND EGRESS ROUTES FOR MATERIAL AND EQUIPMENT. H. PROTECT EXISTING FLOORS, WALLS AND CORNERS TO REMAIN ALONG WORK ACCESS ROUTES. I. CONTAIN DUST AND DEBRIS WITHIN THE DEMOLITION AREA. Eel STARBVCKSU 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El 7MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O Ir- 06 Q O 3: 00 v, VJ rnLU 0 co Z O Cw c Z 0Y 07 0 z0 Qoo U U W O LU ° LU O 0 ° aW oo a- rnW STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: DEMOLITION FLOOR PLAN SCALE: AS SHOWN VS.le: DEMOLITION PLAN 1 /4" = V-0" SHEET NUMBER: D102 O D7 ITEMS TO PRESERVE ITEMS TO DEMOLISH P1. SECURITY CAMERAS D1. (55) CAN LIGHTS P2. RESTROOM CAN LIGHTS D2. (27) PENDANT LIGHTS D3. TRACK LIGHTS D4. (6) TROFFER 48X24 D5. GRILLES AND DIFFUSERS D6. ROLLER SHADE D7. SIGNAGE & ARTWORK D8. RESTROOM VANITY LIGHT D9. EXIT SIGNAGE D10. EXIT LIGHTING Fn 0 C D5 Leo D 1 0 D 1 4' - 7 3/4" __ D6 m 0 D1 2 0 L D1 D1 P1 P1 uuuuu uuuuuuuu �� �� 177 IIIIIIIIIIIIIIIIIIIIIIIIIII Y 0 0 D7 0 D7 �� 0 �� �� IIIIIIIIIIIIIIIIIIIIIIIIIIII ����� D2 D2 j D1 �i D1 D1 D1 D1 �) D1 O D1 D5 D1 D1 D1 uuuuuuuuuuuuuu I D1� I�uuuuuuuuuuuu�l 10 II D9 2 IIIIIIIIIIIIIIIIIIIIIIIIIIII D5 --� _—� F_--7 IIIIIIIIIIIIIIIIIIIIIIIIIIII D3 D3 II D3 II uuuuuuuuuuuuuu D 1 L___J D2 D5 D5 D5 D5 — DO LJ J LJ L L LL 5 1 I D4 I III Y � L_J 17N A N O 0 0 0 <� 0 0 0 0 CCU 00 0 K� <� 0 � �I o D1 o COS � � `�"' D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 D1 � � D1 D1 D2 D2 VV --�--- D1 0 fr I' IIII hl D2 D2 D2 D2 D2 D1 II� D3 D2 IJ O A< X x� X X D1 C� D1 D1 0 COI- - - � O� �O OL -_ 1 I � III �I I D2 D2 D2 D2 D2 D5 II LL D3 == D1 C CCU D1 0 �J D1 CCU D3 D2 D2 D2 D2 D2 D2 6 I O KEYED NOTES 1. EXISTING STRUCTURE TO REMAIN. 2. DEMOLISH HARD LID CEILING, FRAMING AND ASSOCIATED FASTENERS TO BOTTOM OF STRUCTURE ABOVE. 3. REMOVE EXISTING SOFFIT AS SHOWN. 4. REMOVE EXISTING LIGHTING, WIRING, CONTROLS AND FASTENERS BACK TO ELECTRICAL PANEL AS SHOWN. 5. REMOVE EXISTING SECURITY CAMERAS, LOW VOLTAGE CABLING AND ASSOCIATED CONDUITS. CAMERAS SHALL BE SALVAGED FOR FUTURE REUSE. 6. REMOVE EXISTING SPEAKERS, LV CABLING AND ASSOCIATED FASTENERS. 7. EXISTING EXIT SIGN TO REMAIN. D5 D4 ❑ n ❑ D5 D4 III I I � Y I ILL =LJI II J� 7 GENERAL NOTES A. IF DURING DEMOLITION CONDITIONS ARE REVEALED THAT MAY JEOPARDIZE INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT, GENERAL CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY. B. REMOVE EXTRANEOUS EQUIPMENT AS NECESSARY. C. DEMOLISH AND REMOVE SUSPENDED ACOUSTIC LAY -IN, SPLINE OR GYPSUM/ PLASTER CEILING INCLUSIVE OF HANGERS AND CARRYING CHANNELS, WIRES, CABLES, CONDUIT, ADHERED CEILING TILES, FLEX CONDUIT, ELECTRICAL BOXES, SMOKE DETECTORS, LIGHT FIXTURES AND WIRING, DUCT WORK, PIPING AND SUPPORT HANGERS. CUT HANGERS FLUSH. SPACES RECEIVING WALL DEMOLITION WILL ALSO HAVE CEILING DEMOLITION UNLESS OTHERWISE NOTED. D. REMOVAL OF LOW VOLTAGE EQUIPMENT, PERTAINING TO DATA/ COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED BY STARBUCKS CONSTRUCTION MANAGER PRIOR TO REMOVAL. SALVAGED EQUIPMENT SHALL BE STORED IN A CLIMATE CONTROLLED ENVIRONMENT FOR FUTURE INSTALLATION. LEGEND ITEM TO BE DEMOLISHED L J PRESERVE FOR FUTURE USE EXISTING ITEM TO REMAIN STARBVCKSU 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS D 7MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 'x W Q Q O 00 U Q �� V^^ J U) 0 w0 O� Z LULU 0 z0 Qoo U U Ll.l O W ° W O ° 0- W 000 d a) W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: DEMO REFLECTED CEILING PLAN SCALE: AS SHOWN DEMOLITION REFLECTED CEILING PLAN scale: 1 /4" = V-0" SHEET NUMBER: D103 E:S LEGEND KEYED NOTES ITEM TO BE DEMOLISHED 1. DEMO EXISTING RTU'S. 2. TRASH ENCLOSURE ROOF TO REMAIN AS IS. 3. EXISTING EXHUAST TO REMAIN. 4. EXISTING ICE MACHINE CONDENSER TO REMAIN. 5. EXISTING ROOF HATCH TO REMAIN AS IS. GENERAL NOTES A. IF DURING DEMOLITION CONDITIONS ARE REVEALED THAT MAY JEOPARDIZE INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT, GENERAL CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY. B. REMOVE EXTRANEOUS EQUIPMENT AS NECESSARY. STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El 7MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 06 Q O co w 0 LU O G 7 IY n Q v/ z0 < Z U U W O LU ° LU O 0 ° 0- W oo o_ rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: DEMO ROOF PLAN 1 Ds.IE1'V _ROOF PLAN SCALE: AS SHOWN SHEET NUMBER: D 104 LEGEND BUIDLING SIGNAGE SHOWN FOR REFERENCE AND COORDINATION PURPOSES ONLY. BUILDING SIGNAGE TO BE COVERED UNDER SEPERATE PERMIT ITEM TO BE DEMOLISHED PRESERVE FOR FUTURE USE DEMO EAST ELEVATION DEMO WEST ELEVATION Scale: 1 /4" = V-0" —/ Scale: 1 /4" = V-0" KEYED NOTES 1. EXISTING TO REMAIN. 2. EXISTING SIGNAGE TO BE REMOVED, GC TO PATCH AND REPAIR EXISTING EXTERIOR WALL MATERIALS AND FINISHES TO MATCH EXISTING ADJACENT MATERIALS. 3. EXISTING CONCRETE BOLLARD. 4. SEE DEMOLITION PLAN FOR OUTDOOR FURNITURE. 5. EXISTING RAILING TO BE REMOVED. PATCH AND REPAIR SIDEWALK AS NEEDED. 6. EXISTING BIKE RACK. GENERAL NOTES A. IF DURING DEMOLITION CONDITIONS ARE REVEALE THAT MAY JEOPARDIZE INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT, GENERAL CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY. B. GENERAL CONTRACTOR IS RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO DEMOLITION TO REVEAL FULL SCOPE OF WORK. NOTIFY STARBUCKS CONSTRUCTION MANAGER IF EXISTING CONDITIONS DEVIATE FROM CONSTRUCTION DOCUMENTS. C. DEMOLITION PLANS REPRESENT APPROXIMATE LOCATION OF ITEMS TO BE DEMOLISHED. PRIOR TO DEMOLITION, FIELD VERIFY THAT ITEMS TO BE DEMOLISHED DO NOT PROVIDE SUPPORT FOR EXISTING BUILDING ELEMENTS AND EXISTING CONSTRUCTION TO REMAIN. NOTIFY STARBUCKS CONSTRUCTION MANAGER IF DEMOLITION WALLS SUPPORT EXISTING BUILDING ELEMENTS. D. VERIFY WITH STARBUCKS CONSTRUCTION MANAGER ACCESS TO THE DEMOLITION AREA, INGRESS AND EGRESS ROUTES FOR MATERIAL AND EQUIPMENT. E. PROTECT EXISTING DRIVE-THRU EQUIPMENT, BOLLARDS, AND CURBS TO REMAIN ALONG WORK ACCESS ROUTES. F. CONTAIN DUST AND DEBRIS WITHIN THE DEMOLITION AREA. G. THE GENERAL CONTRACTOR SHALL PERFORM WORK IN A MANNER THAT DOES NOT DAMAGE THE EXISTING STRUCTURE. DEMOLITION SHALL NOT COMPROMISE THE STRUCTURAL INTEGRITY OF ANY WALLS, FLOORS, CEILINGS, SUPPORTS, STRUCTURE, ETC. TO REMAIN. H. ALL DEMOLITION MATERIALS AND DEBRIS SHALL BE DISPOSED OF ACCORDING TO FEDERAL, STATE AND LOCAL REGULATIONS. STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD :0 GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS D C TIN LEE HILL OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O ,r W Q Q O 00 3: O C/) Q co Z LU 0 07 o zp < Z U U W O w 0 w O ° 0- W 000 o_ am W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: DEMO EXTERIOR ELEVATIONS SCALE: AS SHOWN T1EEMO NORTH ELEVATION SHEET NUMBER: D201 SITE SCHEDULE - "Y" DESIGN ID COUNT DESCRIPTION FURN. BY I INST. BY COMMENTS X4001 1 4" STEEL POST FOR STRING LIGHTS IGC IGC REFERENCE DETAIL 5/A003 EXTERIOR MENU 22540 1 MENU BOARD - DT 5 PANEL SQUARE FRAME FREESTANDING - 95X621N 2415X1575MM - BLACK SB SB SUPPLIER: DT SIGNAGE VENDOR (DSA) INSTALLER: REGIONAL SIGNAGE VENDOR 22542 1 MENU BOARD - DT PRE MENU SQUARE FRAME FREESTANDING - 29X611N 735X1550MM - BLACK SB SB SUPPLIER: DT SIGNAGE VENDOR (DSA) INSTALLER: REGIONAL SIGNAGE VENDOR 22546 1 MENU BOARD - DT DIGITAL ORDER SCREEN WITH POST - BLACK SB SB SUPPLIER: IT EQUIPMENT VENDOR (ZONES) SCREEN INSTALLER: REGIONAL SIGNAGE VENDOR ELECTRICAL: GC CONNECTS DOS WHIPS & STUB -UPS TO DCB; (NCR) - LOW VOLTAGE OTHER 22543 1 DT ORDER POINT CANOPY SQUARE FRAME - BLACK SB GC GC TO COORDINATE WITH SB VENDOR 23113 1 GROUND GRAPHICS DT ENTRY STENCIL GC GC REFERENCE PAINT 20511 FOR SPECIFICATIONS 23115 1 GROUND GRAPHICS DO NOT ENTER STENCIL GC GC REFERENCE PAINT 20511 FOR SPECIFICATIONS 23117 2 GROUND GRAPHICS ARROW STENCIL GC GC REFERENCE PAINT 20511 FOR SPECIFICATIONS PLANTER 14451 3 PLANTER - BOX - 36X18X181N 915X455X455MM - BLACK SB GC GC TO SUPPLY LINER SOIL, AND SNAKE PLANTS FOR PLANTERS. ADD LAYER OF GRAVEL AT BOTTOM OF PLANTER WITH A FILTER FABRIC. RUN WATER THROUGH THE PLANTERS TO GET RID OF INITIAL RUN OFF, THEN CLEAN RUN OFF FROM PATIO. UMBRELLA 12147 3 UMBRELLA - BASE 95LB 43KG - FLAT BLACK MT0028 SB GC 20073 3 UMBRELLA - WITHOUT VALANCE - 6FT 183CM - GREEN CANVAS WITH WORDMARK F0056 SB GC 1 A003 S 23077 O 2'- 4 1 /4 �uw 27) PIPMEFEAN S 23077 O 1 A003 Y 23117 10 Y 23117 �� 10 2'-10" Y 23113 � w g 0 � w 15 LEGEND . Y EXISTING LANDSCAPE AREA EXISTING CONCRETE WALKWAY AND CURB NEW CONCRETE WALKWAY NEW 6" (150MM) CONCRETE CURB CONCRETE DRIVE THRU LANE ----- ACCCESSIBLE PATH OF TRAVEL 15 10 14451 17 A003 1� 7'-61/2" -S23071 \\ CO LJ CO T - 3" 0 e® MM w Y 23115 � � 10 a ® a O 3 0 A301 02 DY 22542 12 14 TT 11 Y22543 13 Y 22546 o 15 Y22540 �° ld 4 1114 0 121 STARBUCKS TENANT SPACE a 4a 1,785SF ------------ ---- ------ a 14 ° ° — �I — — — a 1 � � �LI _ EDMONDS WAY GENERAL NOTES A. REFER TO EXTERIOR ELEVATIONS ON SHEET A201 FOR BUILDING SIGNAGE LOCATION AND DESIGN ID. REFER TO ELECTRICAL PLANS FOR ELECTRICAL REQUIREMENTS. B. LANDSCAPING TO BE PROVIDED PER ZONING CODE AND SUSTAINABILITY REQUIREMENTS. C. DRIVE-THRU EQUIPMENT INCLUDING VEHICLE DETECTION LOOP, WIRELESS COMMUNICATION AND MONITORS SHALL BE COORDINATED BY STARBUCKS CONSTRUCTION MANAGER. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL REQUIREMENTS. D. PROVIDE 6" (150MM) THICK CONCRETE PAVING THE LENGTH OF THE DRIVE-THRU LANE, EXTENT TO INCLUDE DRIVE-THRU ENTRY POINT THROUGH WINDOW STANDING PAD. E. GENERAL CONTRACTOR TO APPLY CONCRETE SEALER TO ALL EXTERIOR CONCRETE PATIO AND WALKWAY SURFACES. F. GENERAL CONTRACTOR TO VERIFY ALL EXISTING ELEVATIONS AND BUILDING CONDITIONS IN FIELD PRIOR TO START OF CONSTRUCTION. G. PROVIDE DETECTABLE WARNING (IF APPLICABLE PER LOCAL CODE) AT TRANSITION FROM SIDEWALK TO DRIVE AISLE. H. ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL HAVE SURFACE SLOPE NOT TO EXCEED 2% IN ALL DIRECTIONS. I. REFER TO ELECTRICAL DRAWINGS FOR SITE RELATED ELECTRICAL WORK. J. SCRAPE AND REPAINT ALL EXISTING PAINTED SITE FEATURES, INCLUDING, BUT NOT LIMITED TO CURBS, BOLLARDS, RAILINGS AND SITE LIGHTING BASES. K. SEE SHEET A002 FOR ARCHITECTURAL SITE DETAILS. KEYED NOTES 1. EXISTING LANDSCAPE AREA. 2. EXISTING CANOPY (ABOVE). 3. GAS METER LOCATION. 4. EXISTING TRANSFORMER. 5. EXISTING LIGHT POLE. 6. BIKE RACKS, EXISTING. 7. DT DIRECTIONAL ARROW SIGN ON EXISTING FOUNDATION. GC TO COORDINATE WITH SIGN VENDOR. 8. DT DIRECTIONAL EXIT/THANK YOU SIGN ON NEW FOUNDATION. GC TO COORDINATE WITH SIGN VENDOR. 9. CLEARANCE BAR, EXISTING. 10. WAYFINDING PAVEMENT GRAPHICS. 11. DIGITAL ORDER SCREEN WITH CANOPY. USE EXISTING FOOTING BOLTS FOR MOUNTING. 12. INSTALL IN SAME LOCATION AS PREVIOUS PRE -MENU BOARD. 13. RECONNECT DT TIMER LOOP TO NEW EQUIPMENT. 14. EXISTING BOLLARDS TO REMAIN. 15. INSTALL IN SAME LOCATION AS PREVIOUS MENU BOARD. 16. NEW STRIPING BY GC 17. GC IS TO SUPPLY THE SOIL AND LINER FOR THE PLANTERS AS WELL AS THE PLANTS (NEW ZEALAND FLAX, ANYTHING DROUGHT TOLERANT/ LOW MAINTENANCE, OR MATCHING TO PLANT SPECIES ALREADY ON SITE). 18. TRASH ENCLOSURE. STARBVCKSU 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS D MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O '— W Q Q O 00 VJ � LLI LU O �z � 07 0� z0 < Z U U Ll.l O W LU r 0- W LL V/ LLI STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: ARCHITECTURAL SITE PLAN SCALE: AS SHOWN SITE PLAN N N Scale: 1 " = 10'-0" SHEET NUMBER: A001 ALL SITE SIGNAGE DETAILS ARE FOR REFERENCE ONLY; STARBUCKS SIGNAGE VENDOR TO PROVIDE FINAL PERMITTED DRAWINGS, SPECIFICATIONS AND ENGINEERED DETAILS. CUT-OUT THRU HOLE FOR MOUNTING (TYP.) (V00 co ANCHOR BOLT r (TYP 1 OF 4) "v 4" X 4" X 0.25" STEEL q%13 TUBE POST WELDED 00 TO STEEL BASE PLATE LO 1 3/8" BASE N FRONT EDGE FACING PLATE DRIVE THRU LANE DTE DOS CANOPY BASE PLATE 11 Scale:' cale: BASE COVER OUTLINE OUTLINE OF DOS POST BASE PLATE ANCHOR BOLT (TYP.): (4) AT EACH CANOPY BASE PLATE (4) AT DOS BASE PLATE — EDGE OF CONCRETE FOOTING OUTLINE OF CANOPY BASE PLATE (TYP. 1 OF 2)) 0 (V SEE SEPARATE DETAIL FOR ANCHOR ROD PATTERN IN FOUNDATION ALTERNATE ADHESIVE POST -INSTALLED ANCHORS: HILTI 5/8" DIA. HVU ADHESIVE CAPSULES AT 9" EMBEDMENT WITH A36 HOT -DIPPED GALVANIZED THREADED STEEL RODS AND HARDWARE. (12) REQUIRED SEE GROUND FOOTING DETAIL FOR ROD LENGTH (3) 1/2" HEAVY HEX NUTS & WASHER - GALVANIZED TACK NUT TO ROD 5/8" HEAVY HE (4) 5/8" DIA. A36 THREADED HOT NUT WITH WASHER DIPPED GALVANIZED ANCHOR RODS WITH GALVANIZED HARDWARE SITE -SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER 12 DTE DOS CANOPY ANCHOR ROD scae 3 — 1 0 ELECTRICAL TO BE INDIVIDUAL BRANCH CIRCUIT IN DEDICATED CONDUIT TO BOH ELECTRICAL PANEL BY G.C. g ggg0 ALL ROUTE ALL CONDUIT Cl) ANCHORS TO CONDUIT PER STUB -UPS TO BE PROVIDED ELECTRICAL BE 3" ABOVE BY G.C. SITE PLAN FOOTING / a. a 0- 2'- 5° 2" 2�� 2�� 3'- 1 „ / m m m / co w ccnn oU)coa 1_O O O cn o- a 0 00 .._ — — ---- d— �_—_�--°� ---- ---m --—•— °I a.i_ ` 4 d 00 d °- DOS STUB -UPS CANOPY LIGHTING 4" 4" 1" DIA. STUB -UP; ROUTE TO 7" 8" 1' - 1" 8" 1' SIGNAGE POWER 6'-0" DTE ORDER POINT CANOPY BOLT PATTERN (TOP VIEW) scale: 1 " = V-0" FRONT ELEVATION / 4'-6" CANOPY ABOVE DOS AND SPEAKE 00 STEEL BASE PLA- I WELDED TO STEE `? ' POSTS BY MFR. 5/8" HOT DIPPED Xv GALVANIZED LEVELING NUTS ORDER (12) REQUIRED Rr, NON-STRUCTURA p. BASE COVER NATURAL GRADE OR ENGINEERED FILL I o - I' 6" MIN. a = - .l I _=_-- - - oW =1; ° ° � -ill a � q: �a - ,. - — - e aaQ_a' (12) 5/8" DIA. O O P� GALVANIZED ANC III a `,B WITH 6" MIN. EMB LU 3" PROJECTION A a Q ° e (TYP. AT EACH PL � O O CONDUIT 3" CLR. (5) #5 LONG LENC 791 6'- 0" LENGTH TOP ANC SITE -SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER DTE DOS CANOPY GROUND FOOTING 7" U = =ry 0 — � W > > F w w 0 0 0 SIDE ELEVATION SEE GROUND FOOTING DETAIL FOR ROD LENGTH CENTER ANCHOR ROD PATTERN IN FOUNDATION (3) 1/2" - 13 HEAVY HEX NUTS ALTERNATE ADHESIVE POST -INSTALLED ANCHORS: & WASHER - GALVANIZED HILTI 1/2" DIA. HVU ADHESIVE CAPSULES AT 4" TACK EMBEDMENT WITH A36 HOT -DIPPED GALVANIZED NUT THREADED STEEL RODS AND HARDWARE. (4) REQUIRED TO ROD 1/2" HEAVY HEX (4) 1/2" DIA. X 9" LENGTH A36 THREADED HOT DIPPED NUT WITH WASHER GALVANIZED ANCHOR RODS WITH GALVANIZED HARDWARE SITE -SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER DTE PRE -MENU ANCHOR ROD Scale: 3" = V-0" V-5" 000 THRU HOLE 4 1/2" 4" 4" 4 1/2" FOR MOUNTING (TYP.) 6" X 3" X 0.1875" STEEL POST r , N WELDED TO - I BASE PLATE J L J0 2 1/2" SQUARE 0L X 1 /4" PLATE E _ — WASHER � 7 n (TYP. 1 OF 4) U r ANCHOR BOLT — I (TYP 1 OF 4) L J Zv 3/4" STEEL FRONT EDGE BASE PLATE 6 1/2" 4" 6 1/2" FACING DRIVE THRU LANE 7 DTE PRE -MENU BASE PLATE scale: 1 1 /2" = V-0" 2'- 0" DIA ALL 8" 8" 8" ANCHORS TO BE 4" 4" PROVIDED BY G.C. - d ANCHOR BOLT d d00 ° (TYP. 1 OF 4) b BASE d OUTLINE I CONDUIT d 1= STUB -UP 3" °. i :. 4:` .' a -d _,IQ .T bo ABOVE FOOTING ad � 14:' <�a7 -1_ SITE -SPECIFIC d H FOOTING ROUTE ° a _��' --J°• _ L:�—�-�_ CONDUIT PER d, a • ENGINEERING ELECTRICAL a ad ° " 00 REQUIRED BY SITE PLAN a tr LICENSED ° ENGINEER DRIVE LANE FACE THIS SIDE DTE PRE -MENU BOLT PATTERN TOP VIEW 6 Scale: 1 1/2" = V-0" 9' _5 1 /All 8 3/4" STEEL MOUNTING BASE WELDED TO POST NON-STRUCTURAL BASE COVER HOT DIPPED GALVANIZED LEVELING NUTS (4) REQUIRED NATURAL GRADE OR ENGINEERED FILL CONDUIT FRONT ELEVATION SIDE ELEVATION G.C. RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD AND DRIVE THRU ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND INSTALL MENU BOARDS ONLY. SITE -SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER DTE PRE -MENU GROUND FOOTING SEE GROUND FOOTING DETAIL FOR ROD LENGTH SEE SEPARATE DETAIL FOR ANCHOR ROD PATTERN IN FOUNDATION (3) 1/2" HEAVY HEX NUTS ALTERNATE ADHESIVE POST -INSTALLED ANCHORS: & WASHER - GALVANIZED HILTI 1/2" DIA. HVU ADHESIVE CAPSULES AT 8" EMBEDMENT WITH A36 TACK HOT -DIPPED GALVANIZED THREADED STEEL RODS AND HARDWARE. NUT (4) REQUIRED TO 41- ROD 1/2" (4) 1/2" DIA. A36 THREADED HOT DIPPED GALVANIZED HEAVY HEX NUT ANCHOR RODS WITH GALVANIZED HARDWARE WITH WASHER SITE -SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER DTE 5-PANEL MENU BOARD ANCHOR ROD \\�7�Scale: 3" = 1'-0" 7"1,4'6„ 7"3/4" STEEL BASE PLATE 5" 2" 2" 2" 2" 5" ANCHOR BOLT 8" X 4" (TYP 1 OF 4) X 0.1875" - STEEL r 1 r 4- `o TUBE POST L J L J WELDED `V 1 0 2 1/2" SQUARE TO BASE ao X 1/4" PLATE PLATE WASHER AL-1 r(TYP. 1 OF 4)) L — - co FRONT EDGE 5" �211 4" 2" 5" THRU HOLE FACING DRIVE FOR MOUNTING THRU LANE (TYP.) 3 DTE 5-PANEL MENU BOARD BASE PLATE scale: 1 1/2" = 1'-0" 2'- 6" DIA. ROUTE CONDUIT 1' - 3" 1' - 3" PER ELECTRICAL SITE PLAN CONDUIT STUB -UP 3" ABOVE FOOTING Oda ° 1 = °4 BASE° - PLATE d = OUTLINE 4°�, ep L • = p. - ALL g 00 ANCHORS TO BE PROVIDED a_ - i A' d d f a — BY G.C. ° 4;,_ (4) ANCHOR BOLTS FRONT EDGE 4 • ° ° _ OF DRIVE LANE SIDE 11" 8" 11" SITE -SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER DTE 5-PANEL MENU BOARD BOLT PATTERN (TOP VIEW Scale: 1 1/2" = V-0" co M CD 7'- 10 1/2" FRONT ELEVATION STEEL MOUNTING BASE PLATE WELDED TO STEEL POST HOT DIPPED GALVANIZED LEVELING NUTS (4) REQUIRED NON-STRUCTURAL BASE COVER NATURAL GRADE OR ENGINEERED FILL CONDUIT SIDE ELEVATION DETAIL FOR REFERENCE, EXISTING FOOTING TO BE REUSED WHERE POSSIBLE REFERENCE SIGNAGE DRAWINGS FOR DEPTH. SITE -SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER DT 5-PANEL MENU BOARD GROUND FOOTING Scale: 3/8" = V-0" 1' - 1 1/2" STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS D 40 MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O r Q C] 0o U Q U) Z Z o0C/) z0 a0Z U C) w O W W C] 0� W � coa a mw STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: ARCHITECTURAL SITE DETAILS SCALE: AS SHOWN Scale: 3/8" = V-0" scale: 3/8" = V-0" SHEET NUMBER: A002 ALL SITE SIGNAGE DETAILS ARE FOR REFERENCE ONLY; STARBUCKS SIGNAGE VENDOR TO PROVIDE FINAL PERMITTED DRAWINGS, SPECIFICATIONS AND ENGINEERED DETAILS. NOTE: PVC adhesive (not provided) must be applied wherever PVC couplings and pipe are fitted together. ,r• -'' r NWb a) L � (4) `` (s) (2) * Area free of rebar. %we screen• reinforcing pars, electrical cable or metal objects \ speaker Post i' I I • i (6) Figure 1. Loop area preparation Figure 2. Loop layout and connections • Flatten the loop (folded for shipping) as shown in Figure 2 (1). Fit the pipe securely into the couplings (2). Lay the loop flat in the drive-thru lane and position it as shown in Figure 2. Elevate the loop on supports that are anchored to the ground, as shown in Figure 3. Level the loop so it will be 2 inches (51 mm) or less from the paved surface when the concrete is poured. Fasten the loop to the supports with wire, so it will not float when the concrete is poured. • Pull the loop wires through the PVC loop extension (4). Slide one end of the sleeve coupling (3) over the nipple on the corner fitting of the loop (5), and slide the end of the loop extension into the other end of the sleeve coupling. • Pull the loop wires through the elbow coupling (6) and the remaining 2 foot (.61 meter) piece of PVC (7). Slide the two ends (of 4 & 7) into the coupling (6), positioning the piece of PVC (7) so it points upward, out of the ground. Be certain it is next to and parallel to the outlets of the conduit coming into the speaker post or menu board from the building. 2" (59 mm) between W, - 10" „^ Asphalt or loop and surface of (203 -254 mm) _ ; • Concrete asphalt or concrete �� �: Conduit from 6 - 8 03 mm)• Inside Building dravel 3 Sand Vehlc(e Loop Speaker Detector Loop Supports Post Figure 3. Side vieir of loop in asphalt or concrete N N 3/8" STEEL PLATE 1 1/4" DIA. HOLE FOR CONDUIT STUB -UP 5/8" DIA. BOLT HOLE (TYP. 1 OF 4) 3 DTE DIRECTIONAL SIGNAGE BASE PLATE scale: 3" = 1'-0" CONDUIT STUB -UP OFFSET 2'- 0" DIA. g 3" 3" 9" 3" ABOVE FOOTING a •a ROUTE _ 00 CONDUIT PER a: l ° d ELECTRICAL a4• . SITE PLAN °'1 4TI - ALL ANCHORS TO BE 4 d ` PROVIDED ° ad a BY G.C. < _ dQ _4 "d - 00 a (4) ANCHOR 4� ` BOLTS 00 r 00 STEEL BASE PLATE OUTLINE SITE -SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER DTE DIRECTIONAL SIGNAGE BOLT PATTERN (TOP VIEW scale: 1 1 /2" = V-0" FRONT ELEVATION 1 8 CONDUIT (NOT REQUIRED FOR NON - ILLUMINATED SIGANGE) NATURAL GRADE OR ENGINEERED FILL SIDE ELEVATION G.C. RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD AND DRIVE THRU ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND INSTALL MENU BOARDS ONLY. SITE -SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !il GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS D 7MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 'x W Q Q 00 C/) Q LLI co Z LU O Z [Y 07 0 z0 Qoo U U Ll.l O W W 2i 0 0 a W 0 00 a rnw STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: ARCHITECTURAL SITE DETAILS SCALE: AS SHOWN 4 VEHICLE DETECTOR LOOP SCHEMATIC scale: 12" = 1'-0" J DTE DIRECTIONAL SIGNAGE GROUND FOOTING scale: 3/4" = 1'-0" SHEET NUMBER: A003 WALL BLOCKING KEY SYMBOL ITEM WEIGHT HEIGHT A.F.F. APPROX. WIDTH WORKROOM 128 LBS 36" TO 40" <\ �j HAND SINK (58 KG) (915MM TO 1015MM) 30" (760MM) BEHIND SINK SHELVES ABOVE 200 LBS 48" TO 76" 96" (2440MM) CENTERED ABOVE O COMPARTMENT SINK (91 KG) (1220MM TO 1930MM) COMPARTMENT SINK UPPER O WIRE SHELVES BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR SHELVES AT 300 LBS 32" TO 96" 48" (1220MM) 3/4 (19MM) ACX O MANAGER'S DESK (136 KG) (810MM TO 2440MM) PLYWOOD, CENTERED ON SHELVES <E> EQUIPMENT RACK 300 LBS 76" TO 94" 28" (710MM) 3/4 (19MM) ACX (136 KG) (1120MM TO 2440MM) PLYWOOD, CENTERED ON RACK METRO SHELVES BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR. IN - WALL BLOCKING PREFERRED, HOWEVER EXISTING FRP FINISHED WALL MAY RECEIVE SURFACE MOUNTED, PAINTED WHITE. FREE STANDING METRO RACK SHOULD BE FASTENED TO FLOOR AND/OR SUPPORTED OVERHEAD. REVIEW JUSRISDICTIONAL REQUIRMENTS IN SPCIAL SEISMIC ZONES TO ENSURE SUPPORTS ARE PROPERLY ENGINEERED, O RESTROOM 200 LBS 30" TO 36" 60" (1525MM) AROUND WATER GRAB BARS (91 KG) (760MM TO 915MM) CLOSET RESTROOM 200 LBS COMMERCIAL INSTALLATION REQUIRES CONCEALED O HAND SINK (91 KG) ARM CARRIER. REFER TO MFR'S SPECIFICATION. O . O DIAPER CHANGING 250 LBS 40 1/2" TO 46 1/2" 32" (810MM) BEHIND STATION STATION (113 KG) (1030MM TO 1180MM) OS. . WATER FILTRATION TBD BY O SYSTEM VENDOR COORDINATE LOCATION AND EXTENT WITH PENTAIR SYMBOL ITEM WEIGHT HEIGHT A.F.F. APPROX. WIDTH LOCKERS 300 LBS 60" TO 72" 18" (455MM) PAST LOCKERS OM (3/4" PLYWOOD) (136KG) (1525MM TO 1830MM) EA. SIDE DRIVE THRU 100 LBS 48" TO 78" 48" BEHIND POS AND BARISTA O COMMUNICATIONS (136KG) AT DRIVE THRU WINDOW EQUIPMENT O NUGGET ICE / MILK BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR. DISPENSER COORD. WITH STRUCTURAL. EMPTY WEIGHT APPROX. 600# O PASTRY COOLING BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR RACKS OTEA RACKS BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR NUGGET ICE BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR \/R> DIVERTER OS BE)ARB (8813) OARTWORK BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR ALL ARTWORK, FIXTURES, GC TO PROVIDE WALL BLOCKING AS REQUIRED FOR ACCESSORIES AND TBD BY VENDOR ALL ITEMS FOR A COMPLETE AND SECURE CASEWORK (VARIES) INSTALLATION. EXTEND BLOCKING 8" (205MM) FABRICATIONS NOT BEYOND ON EACH SIDE OF EACH ITEM. OTHERWISE NOTED INTERIOR WALL SCHEDULE TAG DESCRIPTION INSULATION NOTES 2-F-N 3 5/8" 20 GA STUD FURRING WALL NONE FULL HT. WALL. SEE PLAN FOR WALL SHEATHING. 2-T-N 3 5/8" 20 GA STUD FURRING WALL NONE TERMINATE 6" ABOVE CEILING. SEE PLAN FOR WALL SHEATHING. 3-F-N 3 5/8" 20 GA STUDS @ 16" O.C. NONE FULL HT. WALL. SEE PLAN FOR WALL SHEATHING. 3-T-A 3 5/8" 20 GA STUDS @ 16" O.C. ACOUSTIC TERMINATE 6" ABOVE CEILING. PROVIDE 45 DEGREE METAL STUD BRACING AT 48" O.C. FROM STUD WALL TO STRUCTURE ABOVE. SEE PLAN FOR WALL SHEATHING. 3-T-N 3 5/8" 20 GA STUDS @ 16" O.C. NONE TERMINATE 6" ABOVE CEILING. PROVIDE 45 DEGREE METAL STUD BRACING AT 48" O.C. FROM STUD WALL TO STRUCTURE ABOVE. SEE PLAN FOR WALL SHEATHING. I 19 EX 1 1503 WALL SHEATHING KEY SYMBOL DESCRIPTION . INDICATES SHEATHING TRANSITION GYP. WALL BOARD O5/8" (FULL WALL HEIGHT) O(TERMINATE 5/8" GYP. WALL BOARD AT 6" (150MM) ABOVE CEILING) OBOARD 5/8" CEMENTITIOUS BACKER (TERMINATE AT 6" (150MM) ABOVE CEILING) 5/8" CEMENTITIOUS BACKER BOARD (TERMINATE AT FINISH AS SHOWN ON OTRANSITION INTERIOR ELEVATION W/ 5/8" GYP. WALL BOARD ABOVE (FULL WALL HEIGHT)). O(TERMINATE 5/8" PLYWOOD AT 6" (150MM) ABOVE CEILING) KEYED NOTES 1. OUTLINE OF BAR PER CASEWORK MANUFACTURER. 2. ELECTRICAL PANEL LOCATIONS. MAINTAIN MINIMUM CLEARANCE AS REQUIRED BY CODE. 3. 36" (915 MM) CLEAR FOR ROOF LADDER ACCESS. 4. ALIGN FACE OF FINISHED WALL. GENERAL NOTES A. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. B. GENERAL CONTRACTOR TO PROVIDE FIRE TREATED WOOD STUD BLOCKING, OR EQUIVALENT TO SUPPORT ANY WALL ATTACHMENT AND/OR SIGNAGE. C. IF EXISTING EXTERIOR ENTRANCE THRESHOLD EXCEEDS MINIMUM BARRIER FREE PROVISION OF THE CODE, REMOVE AND REPLACE WITH ACCESSIBLE THRESHOLD. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES AT ACCESSIBLE DOORWAYS TO BE BEVELED WITH A SLOPE NO GREATER THAN 1:12. D. ALL DIMENSIONS ARE TO FINISHED FACE UNLESS SHOWN OR NOTED OTHERWISE. E.. INSTALL MOISTURE RESISTANT GREEN BOARD ON BACKBAR WALL PER PROJECT MANUAL. F. ALL DOORS SHALL BE 32" (815MM) MINIMUM CLEAR OPENING WHEN OPENED TO 90 DEGREE POSITION UNLESS OTHERWISE NOTED. G. SEE SHEET A601 FOR EXTERIOR DOOR AND WINDOW SCHEDULES. H. STARBUCKS VENDOR TO PROVIDE DOOR HARDWARE COMPONENTS AND GC TO INSTALL. I. VERIFY ALL EXISTING DOORS, HARDWARE AND FRAMES MEET STARBUCKS AND/OR CODE REQUIREMENTS. J. PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM THE CITY. K. SEE STRUCTURAL FOR KNEE WALL BRACING. L. SEE SHEET A501 FOR BUILDING DETAILS. M. REFER TO SHEET 1104 FOR FLOOR FINISHES. GENERAL LEGEND O NEW FULL HEIGHT WALL EXISTING WALL WALL BLOCKING CALL -OUT WALL SHEATHING CALL -OUT STARBUCKS' 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 06 Q O 3: 00 v, VJ rnLU 0 O CLu c Z 0r 07 0 z0 Qoo U U W O LU ° LU O ° 0 0- W oo o_ rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: BUILDING FLOOR PLAN FLOOR PLAN scale: 1 /4" = V-0" SCALE: AS SHOWN SHEET NUMBER: A101 1S,-0114" KEYED NOTES 1. ELECTRICAL STUB -UP LOCATION. SEE ELECTRICAL SHEETS. 2. PLUMBING STUB -UP LOCATION. SEE PLUMBING SHEETS 3. EXISTING FLOOR SINK LOCATION, PROVIDE NEW GRATE. 4. NEW FLOOR SINK LOCATION. SEE PLUMBING SHEETS. 5. EXISTING MOP SINK WASTE. 6. EXISTING TOILET WASTE. 7. DEMO EXISTING FLOOR SINK AND CAP PLUMBING. 8. 3/4" DATA CONDUIT 9. 3/4" CONDUIT TO ELECTRICAL PANEL 10. 1" CONDUIT FROM DT POS TO BOH NETWORK RACK TO RUN OVERHEAD. 11. NEW BELOW S.O.G. GREASE INTERCEPTOR. REFER TO PLUMBING DRAWINGS FOR FURTHER INFORMATION AND GREASE INTERCEPTOR SPECIFICATIONS. 12. PROPOSED LOCATION AND SIZE OF S.O.G. SAW -CUTTING REQUIRED FOR NEW GREASE INTERCEPTOR INSTALLATION. PRIOR TO SAW -CUTTING GC TO VERIFY LOCATION AND ALL DIMENSIONS AGAINST PLUMBING PLANS AND GREASE INTERCEPTOR SPECIFICATION AND INSTALLATION REQUIREMENTS PER MANUFACTURE. S.O.G. TO BE BACK FILLED AND PATCHED TO INTERCEPTOR ACCESS PORTHOLE PER MANUFACTURES RECOMMENDATIONS. 13. INSTALL NEW SAMPLING PORT (SV-10) DOWN FLOW FROM NEWLY INSTALLED GREASE INTERCEPTOR, PRIOR TO RESTROOM WASTE LINES. REFER TO PLUMBING DRAWINGS FOR FURTHER INFORMATION. LOCATION SHOWN FOR GENERAL REFERENCE ONLY. REFER TO PLUMBING DRAWINGS FOR SPECIFIC LOCATION AND REQUIREMENTS. 14. RECESSED WALK OFF MAT. GENERAL NOTES A. ALL STUB -UP DIMENSIONS ARE RELATIVE TO FINISHED WALL LOCATIONS (SHOWN AS OUTLINES ON THIS PLAN). REFER TO FLOOR PLAN FOR WALL PLACEMENT. B. FLOOR SINK: REFER TO CUT SHEETS FOR COMPONENT SPECIFICATIONS AND CUTOUT REQUIREMENTS. C. WASTE LINE PENETRATIONS: REFER TO PLUMBING PLANS FOR INDIVIDUAL LINE LOCATIONS. D. STUB -UP PENETRATIONS: REFER TO ELECTRICAL AND PLUMBING PLANS FOR INDIVIDUAL STUB -UP LOCATIONS. E. TOILET FLOOR PENETRATION: REFER TO CUT SHEETS FOR STUB -UP LOCATION RELATIVE TO FINISHED WALL. F. PENETRATION TO BE LOCATED ON CENTERLINE OF WALL OR AS REQUIRED PER CONDITIONS. G. TRENCHING OUTLINE FOR GUIDELINE USE ONLY. GENERAL CONTRACTOR TO COORDINATE WITH SPECIFIC TRADES AND SITE CONDITIONS TO DETERMINE ACTUAL LAYOUT. H. REFER TO SHEET 1101 FOR FLOOR FINISHES. LEGEND EXISTING WALL NEW WALL DATUM POINT FLOOR SINK FLOOR DRAIN DATA CONDUIT POWER CONDUIT STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El 7MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 06 Q O 3: 00 v, VJ rnLU 0 O Cw c Z 0' 0 07 z0 Qoo U U W O LU ° LU O 0 ° 0- W oo a- rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: BUILDING FLOOR PENETRATION PLAN SCALE: AS SHOWN FLOOR PENETRATION PLAN scale: 1 /4" = V-0" SHEET NUMBER: A102 KEYED NOTES 1. NEW RTU'S PLACED IN SAME LOCATION AS DEMOLISHED RTU'S. 2. TRASH ENCLOSURE ROOF. 3. REPAIR ROOF MEMBRANE AS NEEDED. GENERAL NOTES A. IF DURING DEMOLITION CONDITIONS ARE REVEALED THAT MAY JEOPARDIZE INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT, GENERAL CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY. B. REMOVE EXTRANEOUS EQUIPMENT AS NECESSARY. STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El 7MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 06 Q O 3: W T VJ VJ rn 0 LU O Cw c Z Ir 07 0 z0 < Z U U W O LU ° LU O 0 ° 0- W oo o_ rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: ROOF PLAN ROOF PLAN scale: 1 /4" = 1'-0" SCALE: AS SHOWN SHEET NUMBER: Al03 BUIDLING SIGNAGE SHOWN FOR REFERENCE AND COORDINATION PURPOSES ONLY. BUILDING SIGNAGE TO BE COVERED UNDER SEPERATE PERMIT SIGNAGE SCHEDULE - "S" DESIGN ID I COUNT DESCRIPTION FURN. BY INST. BY BULB COMMENTS SIGNAGE 23098 1 SIGN - DRIVE THRU ILLUMINATED RACEWAY GREEN - 81N 205MM SB SV EXTERIOR SIGNAGE - GREEN LETTERS, GC TO COORDINATE WITH SB VENDOR 23100 1 SIGN - DRIVE THRU ILLUMINATED RACEWAY GREEN - 121N 305MM SB SV EXTERIOR SIGNAGE - GREEN LETTERS, GC TO COORDINATE WITH SB VENDOR SIGNAGE - DISK 22606 1 SIGN - DISK SF ILLUMINATED FLUSH MOUNTED EVOLVED - 721N 1830MM SB SV EXTERIOR SIGNAGE, GC TO COORDINATE WITH SB VENDOR SIGNAGE - DRIVE THRU 23071 1 SIGN - DIRECTIONAL EXIT ONLY ILLUM DS - EXG FOUNDATION - 441N SB SV GC TO COORDINATE WITH SB VENDOR 23077 2 SIGN - DT DIRECTIONAL ARROW ILLUM DS - EXG FOUNDATION - 441N 1120MM SB SV GC TO COORDINATE WITH SB VENDOR EAST ELEVATION scale: 1 /4" = V-0" Fn Fn KEYED NOTES 1. EXISTING TO REMAIN (ETR). 2. PROVIDE J-BOX FOR BUILDING SIGNAGE. COORDINATE LOCATION WITH SIGNAGE VENDOR SHOP DRAWINGS. 3. PROVIDE SIGNAGE DISCONNECT ON INSIDE FACE OF WALL. 4. 3/4" MARINE GRADE PLYWOOD BLOCKING FOR EXTERIOR SIGNAGE. EXTEND BLOCKING 8" (205MM) MIN. BEYOND EDGE OF SIGNAGE. 5. ALIGN NEW DRIVE THRU RACEWAY SIGN WITH CENTERLINE OF EXISTING SIREN DISK SIGN. 6. PAINT RACEWAY, KEYSTONE GRAY (SW7504) - DID X7504. GENERAL NOTES A. GENERAL CONTRACTOR TO COORDINATE AND SCHEDULE SIGNAGE INSTALLATION WITH THE SIGNAGE CONTRACTOR PROVIDING A MINIMUM SCHEDULING NOTICE OF 4 WEEKS AND 1 WEEK PRIOR TO SCHEDULED DATE OF INSTALLATION CONSTRUCTION MANAGER TO PROVIDE GENERAL CONTRACTOR WITH SIGNAGE CONTRACTOR CONTACT INFORMATION. B. GENERAL CONTRACTOR SHALL COORDINATE WITH ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL ELECTRICAL CIRCUITS INCLUDING ALL CONDUIT, WIRE, CONNECTIONS AND BREAKER AT PANEL BOARD NECESSARY TO SERVE SIGNAGE. C. GENERAL CONTRACTOR TO PROVIDE FIRE TREATED WOOD STUD BLOCKING OR EQUIVALENT TO SUPPORT SIGNAGE. D. SIGNAGE CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ANY AND ALL ALLOWABLE MONUMENT OR POLE SIGNAGE AND PROVIDE SHOP DRAWING(S) PRIOR TO FABRICATION TO THE STARBUCKS DESIGNER FOR APPROVAL. E. SIGNAGE CONTRACTOR TO INSTALL SIGNAGE IN COMPLIANCE WITH LOCAL CODES AND OBTAIN PERMIT. F. SIGNAGE CONTRACTOR TO SUPPLY SHOP DRAWINGS TO CONSTRUCTION MANAGER AND TO THE GENERAL CONTRACTOR AS NEEDED. GENERAL CONTRACTOR TO NOTIFY CONSTRUCTION MANAGER IMMEDIATELY IF SHOP DRAWINGS OR INSTALLATION IS IN DISCREPANCY WITH ARCHITECTURAL DRAWINGS. G. GENERAL CONTRACTOR TO CLEAN, PATCH AND REPAIR EXISTING EXTERIOR AS REQUIRED. STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El 7MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 'x W Q Q O 00 O C/) Q w p LU O Z 0 Uj o z 0 a p Z U U W O LU 0 LU O 000p 0- W Il rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: BUILDING EXTERIOR ELEVATIONS SCALE: AS SHOWN 3 cale: 1 /4" = V-NORTH ELEVATION s0" SHEET NUMBER: A201 BUIDLING SIGNAGE SHOWN FOR REFERENCE AND COORDINATION PURPOSES ONLY. BUILDING SIGNAGE TO BE COVERED UNDER SEPERATE PERMIT WEST ELEVATION scale: 1 /4" = V-0" KEYED NOTES 1. EXISTING TO REMAIN (ETR). INSTALL SOLAR MIRROR FILM ON INTERIOR FACE OF EXISTING GLAZING. PROVIDE (1) 4"x12" PASSIVE WALL GRILLE PAINTED TO MATCH WALL FINISH WITHIN EACH SECTION OF STOREFRONT, BOTTOM OF GRILLE TO BE 12" AFF MAX. ENSURE TOP OF CAVITY FRAMING REMAINS OPEN TO PLENUM FOR ADEQUATE VENTILATION OF THE ENCLOSED STOREFRONT CAVITY GENERAL NOTES A. GENERAL CONTRACTOR TO COORDINATE AND SCHEDULE SIGNAGE INSTALLATION WITH THE SIGNAGE CONTRACTOR PROVIDING A MINIMUM SCHEDULING NOTICE OF 4 WEEKS AND 1 WEEK PRIOR TO SCHEDULED DATE OF INSTALLATION. CONSTRUCTION MANAGER TO PROVIDE GENERAL CONTRACTOR WITH SIGNAGE CONTRACTOR CONTACT INFORMATION. B. GENERAL CONTRACTOR SHALL COORDINATE WITH ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL ELECTRICAL CIRCUITS INCLUDING ALL CONDUIT, WIRE, CONNECTIONS AND BREAKER AT PANEL BOARD NECESSARY TO SERVE SIGNAGE. C. GENERAL CONTRACTOR TO PROVIDE FIRE TREATED WOOD STUD BLOCKING OR EQUIVALENT TO SUPPORT SIGNAGE. D. SIGNAGE CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ANY AND ALL ALLOWABLE MONUMENT OR POLE SIGNAGE AND PROVIDE SHOP DRAWING(S) PRIOR TO FABRICATION TO THE STARBUCKS DESIGNER FOR APPROVAL. E. SIGNAGE CONTRACTOR TO INSTALL SIGNAGE IN COMPLIANCE WITH LOCAL CODES AND OBTAIN PERMIT. F. SIGNAGE CONTRACTOR TO SUPPLY SHOP DRAWINGS TO CONSTRUCTION MANAGER AND TO THE GENERAL CONTRACTOR AS NEEDED. GENERAL CONTRACTOR TO NOTIFY CONSTRUCTION MANAGER IMMEDIATELY IF SHOP DRAWINGS OR INSTALLATION IS IN DISCREPANCY WITH ARCHITECTURAL DRAWINGS. G. GENERAL CONTRACTOR TO CLEAN, PATCH AND REPAIR EXISTING EXTERIOR AS REQUIRED. STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El 7MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 06 Q O co w 0 LU O G 7 0 Q v/ 07 z0 < Z U U W O LU ° LU O 0 ° 0- W oo o_ rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: BUILDING EXTERIOR ELEVATIONS SOUTH ELEVATION scale: 1 /4" = V-0" SCALE: AS SHOWN SHEET NUMBER: A202 N N PATIO BENCH - ENLARGED PLAN scale: 3/4" = V-0" PATIO BENCH ELEVATION scale: 1 1/2" = V-0" DID:11377 FROM ABOVE PVC PIPE (IN MOLD) PATIO BENCH ENLARGED DETAIL PLAN scale: 1 1/2" = V-0" /4" OFFSET TO CONCRETE TIMBERTECH AZEK 1" X 3.5"- ENGLISH WALNUT PATIO BENCH PVC scale: 6" = V-0" TIMBERTECH AZEK 1" X 3.5"; ENGLISH WALNUT PVC HOLE IN CONCRETE 2" X 2" X 1/8" STEEL TUBE SILICONE F- Lu co z v F- UU z FROM UNDERSIDE AND LIGHT DETAIL SECTION 1 9 /7" All 2" X 2" METAL TUBE ROPE LIGHT COMPOSITE BOARD • •°4 dq =TE 90 2,, OR :ST 9 CH -d e :AT =TE • o- _ d a ND d, _ a, d,a a q d a. CV _ a 4' a = g °d a d _ - 1'- 4 3/4" 5 1/2" PATIO BENCH SECTION scale: 3" = V-0" STARBUCKS®R 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD :0 GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 XRIGISDI CSTATE TIN LEE HILL OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O r 06 O 3: TW V / U) U) U) 7 Z ft Q O C/) 20 z0 a oz U U w O W 0 W MO 0^ �) �/ WT I0I I W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: PATIO BENCH DETAILS I SCALE: AS SHOWN SHEET NUMBER: A301 7" EQ EQ - - - - - - - - - - - - - - - - - - M r-- --� — M 2 Uj ALL CONDUIT STUB -UPS TODIMENSION BE WITHIN THIS POINT BOUNDARY POS DIEWALL ESPRESSO BAR PLUMBING STUB -UP KEY 11 CWF STUB -UP 21 CW STUB -UP NOTE: SEE SHEET A102 -BUILDING FLOOR PENETRATION PLAN FOR FINAL DIMENSIONED LOCATION. PLUMBING STUB -UPS AT ESPRESSO BAR scale: 1 1/2" = 1'-0" 3/4" CDX MIN, FLOOR OR ROOF DECK, TYP THROUGHOUT THIS DETAIL 2 X 6 (MIN) FLOOR OR ROOF FRAMING (JOISTS) AT 24" MAX OC, TYP THROUGHOUT THIS DETAIL/ TYPICAL AT ALL SITUATIONS INDICATED HERE: NESTED TRACKS (20GA MINIMUM, UON) OR SLOTTED TRACK (20GA MINIMUM, LION) TO ALLOW 1/2" DEFLECTION. TRACKS PER ES REPORT ESR-1042. STUDS CUT 1/2" SHORT TO ALLOW FOR 1/2" DEFLECTION FINISH MATERIALS (WHERE OCCUR) HELD 1/2" SHORT OF TOP OF TRACK TO ALLOW FOR 1/2" DEFLECTION. DO NOT SCREW FINISH MATERIALS INTO TOP TRACK - FASTEN INTO STUDS ONLY ACOUSTICAL SEALANT IN 1/2" DEFLECTION GAP AT PARTITIONS WITH ACOUSTICAL INSULATION 1'-9" EQ EQ ___ _______________________ COS A 000 000 w ALL CONDUIT STUB -UPS TO DIMENSION BE WITHIN THIS DATUM POINT BOUNDARY ESPRESSO BAR DIEWALL ESPRESSO BAR ELECTRICAL STUB -UP KEY 1 3/4" LAN CONDUIT 2 3/4" LAN CONDUIT TO MANAGER'S WORKSTATION 3 3/4" ISOLATED GROUND POWER CONDUIT NOTE: SEE SHEET A102 - BUILDING FLOOR PENETRATION PLAN FOR FINAL DIMENSIONED LOCATION. ELECTRICAL STUB -UPS AT ESPRESSO BAR scale: 1 1/2" = 1'-0" I 2 X 4 MINIMUM BLOCKING, FASTENED TO JOISTS WITH (1)A34 ANCHOR EACH END / (2) NO 10 X 1 1/4" WOOD SCREWS AT 24" MAXIMUM OC (2) NO 10 X 1 1/4" WOOD SCREWS AT 24" MAXIMUM OC ( PARTITION PERPENDICULAR TO JOIST + I\/I + IXI + I/\I l B) PARTITION PARALLEL TO JOISTS + + :7 2X BLOCKING MAI BE ADDED FOR ACOUSTICAL SEPARATION, HVP SEPARATION, OR DRAFT STOPPING (2) NO 10 X 1 1/4" WOOD SCREWS A 24" MAXIMUM OC INTERSECTION OF NON -RATED PARTITION W/ SOLID -LUMBER STRUCTURE AND PLYWOOD DECK ABOVE 4 Scale: 3" = 1'-0" METAL STUDS (PER ES REPORT ESR-2054), MAXIMUM HEIGHT 20'-0" FINISH MATERIALS Q } I I VARY (MAXIMUM WEIGHT EQUAL TO 2 p a- O O LAYERS Q F F I I GYPSUM BOARD EACH z m O� I SIDE PLUS O APPLIED FINISHES Q 0 I z? z w 0 I FASTENERS: Q Q AT PLYWOOD FLOOR zof _ Q Fn 00 1 (MINIMUM 3/4" CDX): of Q Uj U g PROVIDE (2) NO 8 X 1" WOOD Q U J Q w Q w I SCREWS AT 24" MAXIMUM OC F_ ? F Y I STAGGERED FOR 1 LAYER Q 1 GYPSUM BOARD EACH SIDE, UO�Qw 16"MAXIMUM OC ci Q 0 Of 0 I STAGGERED FOR 2 LAYERS OD z Q LL zz O I GYPSUM BOARD EACH SIDE Uzw0— Q — O w Q I AT CIP CONCRETE AND _jQU J � w z — POST -TENSIONED CONCRETE z Jof w 1 FOJOw 1 FLOOR: Q U LL U Q I PROVIDE HILTI X-U 0.157" DIAMETER POWDER- ACTUATED FASTENERS, I EMBED 3/4" PER ESR-2269. 24" O I MAXIMUM OC STAGGERED = � I FOR 1 LAYER GYPSUM � D Y Q BOARD EACH SIDE, 16" (3 z MAXIMUM OC STAGGERED �► o � 1 FOR 2 LAYERS GYPSUM ARD EACH SIDE PARTITION TO FLOOR 4 A501 'o-� NON -FIRE RATED PARTITION WITH FULL HEIGHT SHEATHING NON -FIRE RATED PARTITION WITH SHEATHING TERMINATING 6" ABOVE CEILING [AND OTE: C TO VERIFY EXISTING CEILING STRUCTURE VERIFY IF DETAILS NOTED APPLY. PARTITION DESIGNATION VISH TERMINATION =1LING 0 z O LU Q w QLU ILL] w ILL] U) NON -FIRE RATED PARTIAL -HEIGHT PARTITION OPARTITION LOCATED AT DECK EDGE/OPENING r 'v 1'-6" 000 � 000 -- -�- M L — — — — — — —------� If LU ALL CONDUIT w STUB -UPS TO BE WITHIN THIS DIMENSION BOUNDARY DATUM POINT POS DIEWALL POS ELECTRICAL STUB -UP KEY 1 — 3/4" POWER CONDUIT TO ELECTRICAL PANE[ 2 1/2" PHONE TO MANAGER'S DESK 3 1/2" DATA CONDUIT TO MANAGER'S DESK 4 1/2" SECURITY TO MANAGER'S DESK 5 3/4" LAN CONDUIT TO POS/SAFE 6 3/4" POWER CONDUIT FOR PASTRY CASE NOTE: SEE SHEET A102 - BUILDING FLOOR PENETRATION PLAN FOR FINAL DIMENSIONED LOCATION. ELECTRICAL STUB -UPS AT POS scale: 1 1/2" = V-0" + + + + + + + 3 A503 BRACE OF STUDS (OR DOUBLED STUDS) PER DETAIL 2 X 4 MINIMUM BLOCKING AT 48" MAXIMUM OC, FASTENED TO JOISTS WITH (1) A34 ANCHOR EACH END OR ATTACH BRACE DIRECTLY TO ROOF STRUCTURE WHERE STRUCTURE IS PERPENDICULAR TO PARTITION (3) NO 10 X 1 1/4" WOOD SCREWS n PARTITION BRACE TO STRUCTURE WALL ABOVE BAR COUNTER NG STOREFRONT _ 7t co 0 )M OF WALL AT FF INISH PER ELEVATIONS CV R COUNTER )M OF WALL AT TER 2'-10" AFF TER \1 D ffCK CORNER PIECES STARBVCKSU 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS D MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W CD Q Q O 3: > 00 Q C/)co w 0 Z O Z Ir z O Q Z U C) Ll.l O W W 0 d W 0 GD d W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: BUILDING DETAILS SCALE: AS SHOWN scale: 3" = V-0" scale: 1/2" = V-0" scale: 1 " = V-0" SHEET NUMBER: A501 DOOR SCHEDULE - "D" DESIGN ID MARK DESCRIPTION WIDTH HEIGHT HARDWARE SET FURN BY INST BY COMMENTS Exterior EX 01 DOOR - SINGLE SERVICE- 361N 915MM 3'- 0" 7' - 0" EXISTING - - EXISTING TO REMAIN EX 02 DOOR - STOREFRONT METAL FRAME SINGLE - TYPE B 3'- 0" T - 0" EXISTING - - EXISTING TO REMAIN EX 03 DOOR - STOREFRONT METAL FRAME SINGLE - TYPE B 3'- 0" T - 0" EXISTING - - EXISTING TO REMAIN 3 Interior EX 04 DOOR - SINGLE FLUSH - 361N 3'- 0" 7' - 0" EXISTING - - PAINT- SW7020 BLACK FOX EX 05 DOOR - SINGLE FLUSH - 361N 3'- 0" 7' - 0" EXISTING - - PAINT- SW7020 BLACK FOX 10086 06 DOOR - SINGLE IMPACT DOUBLE ACTING - 361N 3' - 0" 7' - 0" 11 GC GC PLAM GRAPHITE 3 DOOR LEGEND INTERIOR INTERIOR INTERIOR SINGLE SINGLE SINGLE FLUSH IMPACT SERVICE DOUBLE ACTING EXTERIOR STOREFRONT METAL FRAME SINGLE (TYPE B) DOOR HARDWARE SET NO. 11 - For workroom door at backbar No. Item Description Manufacturer Finish 1 Traffic Door Package SCP8 36" x 84" Eliason As Selected GENERAL NOTES A. STARBUCKS VENDOR TO PROVIDE DOOR HARDWARE COMPONENTS. GC TO INSTALL. B. SEE SHEET A101 FOR TAGGED LOCATION OF EXTERIOR DOORS AND WINDOWS. STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2021.10.22 ARCHITECT OF RECORD !il GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El 7MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 06 Q O co w 0 LU O G 7 1Y n Q v/ z0 < Z U U W O LU ° LU O 0 ° 0- W oo o_ rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: WINDOW AND DOOR SCHEDULES & DETAILS SCALE: AS SHOWN SHEET NUMBER: A602 KEYED NOTES 1. INSTALL EXTERIOR FURNITURE THROUGHOUT AS SHOWN. 2. INSTALL CAFE FURNITURE THROUGHOUT AS SHOWN. 3. COMMUNITY BOARD. SEE INTERIOR FINISH ELEVATIONS. 4. CONDIMENT CART. SEE INTERIOR FINISH ELEVATIONS. 5. PLACE MERCHANDISE FIXTURES AND RETAIL FLOOR BASKETS PER PLAN. STORE OPERATORS TO ORDER RETAIL FLOOR BASKETS. 6. DO NOT BLOCK FOOD CASE INTAKE/EXHAUST. GENERAL NOTES A. GENERAL CONTRACTOR TO SCHEDULE WITH LOCAL REFRIGERATION CONTRACTOR TO CONDUCT INITIAL FOOD CASE START-UP AND TESTING. FOR LIST OF APPROVED START UP CONTRACTORS, CONTACT PROJECT CONSTRUCTION REPRESENTATIVE. B. THE SITE IS SERVED BY THE MUNICIPAL WATER AND SEWER SYSTEM UNLESS OTHERWISE NOTED. C. ALL FOOD STORAGE SHALL BE 6" (150mm) A.F.F D. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETS) SHALL BE SEALED. E. ALL EQUIPMENT AND INSTALLATION WILL MEET NATIONAL SANITATION FOUNDATION STANDARDS OR EQUIVALENT. 7. WATER HEATER LOCATED ABOVE. SEE PLUMBING F. ALL EQUIPMENT AND CABINETRY WILL BE FLUSH DRAWINGS. MOUNTED TO COUNTERS, WALLS OR FLOORS, OR BE RAISED TO ALLOW FOR CLEANING. 8. SECURE LOCKERS TO WALL. 9. MANAGERS DESK. SEE MANAGER'S DESK / EQUIPMENT RACK ELECTRICAL DETAIL FOR ADDITIONAL INFORMATION. 10. SEE SHEET A301 FOR CUSTOM BENCH DETAILS. YIX40011 YIX4001I F X5500 IHIM III I I I I I I I I Y 20073 [ 17853 F 3] 5] [ i Y 12147 [3] 1 F 17339 [5] RIM' I I � � I � 1 I I F 117341 — F X1010 F X1011 FURNITURE, FIXTURES AND EQUIPMENT PLAN - PATIO scale: 1 /4" = V-0" G. CONFIRM ALL NECESSARY EQUIPMENT CLEARANCES PER PRODUCT CUT SHEET (E.G. ICE MACHINE). H. FOR LOCATION OF COUNTERTOP EQUIPMENT, REFER TO CASEWORK ELECTRICAL DETAILS. I. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS, EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE AS PLACES FOR ACCUMULATION OF DUST, DIRT AND DEBRIS. J. WARMING OVEN(S) SHOWN FOR PERMITTING PURPOSES. INSTALLATION AT STORE OPENING TO BE VERIFIED BY STARBUCKS CONSTRUCTION REPRESENTATIVE. K. EACH HAND WASHING SINK WILL HAVE A SINGLE SERVICE TOWEL AND SOAP DISPENSER, AND ALL HAND SINKS TO HAVE A COMBINATION FAUCET OR PREMIXING FAUCET. L. FOR PLUMBING FIXTURES, REFER TO THE PLUMBING DESIGN PLAN. FOR DATA DEVICE SCHEDULE, REFER TO THE ELECTRICAL DESIGN PLAN. M. SEE ELEVATIONS FOR DISTRIBUTION OF CUP DISPENSERS. N. PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM THE LOCAL JURISDICTION. LEGEND [2] [2] NEW ITEM RELOCATED ITEM EXISTING ITEM TO REMAIN OR FURTURE USE STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 WRIGISDI 7STATE TIN LEE HILL OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 06 Q O 3: W T VJ VJ rn 0 LU O Cw c Z IY 07 0 z0 Qoo U U W O LU ° LU O ° 0 aW oo a- rnW STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: FF&EPLAN FURNITURE, FIXTURES AND EQUIPMENT PLAN scale: 1 /4" = V-0" SCALE: AS SHOWN SHEET NUMBER: 1101 2 UPPER FF&E PLAN Scale: 1/2" = 1'-0" [34'-7"] I L 122217 I E 1 21679 �dddd� I ----------- z 1102 x wwwww�wwww ®wwww. jE 20010 E 22627 I L 1 E 12508 J E 10267 E 11115 E 10977 O [2] A 10029 A 14677 A 10012 A 12336 E 10267 A 10014 A 22726 A 22725 A 14678 / L- KEYED NOTES 1. DO NOT BLOCK FOOD CASE INTAKE/EXHAUST. 2. SAFE LOCATED AT POS CABINET. SEE ELECTRICAL FOR ADDITIONAL INFORMATION. 3. HAND SINK W/ INTEGRAL SPLASH GUARD. 4. STRIP LED TAPE. IE1234451 O r 40 I A 10075 20032 [2] E 23445 2618 E 112618 / I / - -E 17564 ------------ L R 10858 L J E 10791 R 13330 88 E 10855 i Rl 10091 2 A 10075 \DO R El 10396 / E 19742 E 10267 00 R 13584 / R 10267 E 19742 A 10075 1 n O O E 19278 E 19278 O [2] A 10008 A 10024 [2] A 10014 A 10028 \ [4] A 10029 E 23444 GENERAL NOTES A. GENERAL CONTRACTOR TO SCHEDULE WITH LOCAL REFRIGERATION CONTRACTOR TO CONDUCT INITIAL FOOD CASE START-UP AND TESTING. FOR LIST OF APPROVED START UP CONTRACTORS, CONTACT PROJECT CONSTRUCTION REPRESENTATIVE. B. THE SITE IS SERVED BY THE MUNICIPAL WATER AND SEWER SYSTEM UNLESS OTHERWISE NOTED. C. ALL FOOD STORAGE SHALL BE 6" (150mm) A.F.F. D. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETS) SHALL BE SEALED. E. ALL EQUIPMENT AND INSTALLATION WILL MEET NATIONAL SANITATION FOUNDATION STANDARDS OR EQUIVALENT. F. ALL EQUIPMENT AND CABINETRY WILL BE FLUSH MOUNTED TO COUNTERS, WALLS OR FLOORS, OR BE RAISED TO ALLOW FOR CLEANING. G. CONFIRM ALL NECESSARY EQUIPMENT CLEARANCES PER PRODUCT CUT SHEET (E.G. ICE MACHINE). H. FOR LOCATION OF COUNTERTOP EQUIPMENT, REFER TO CASEWORK ELECTRICAL DETAILS. I. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS, EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE AS PLACES FOR ACCUMULATION OF DUST, DIRT AND DEBRIS. J. WARMING OVEN(S) SHOWN FOR PERMITTING PURPOSES. INSTALLATION AT STORE OPENING TO BE VERIFIED BY STARBUCKS CONSTRUCTION REPRESENTATIVE. K. EACH HAND WASHING SINK WILL HAVE A SINGLE SERVICE TOWEL AND SOAP DISPENSER, AND ALL HAND SINKS TO HAVE A COMBINATION FAUCET OR PREMIXING FAUCET. L. FOR PLUMBING FIXTURES, REFER TO THE PLUMBING DESIGN PLAN. FOR DATA DEVICE SCHEDULE, REFER TO THE ELECTRICAL DESIGN PLAN. M. SEE ELEVATIONS FOR DISTRIBUTION OF CUP DISPENSERS. N. PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM THE LOCAL JURISDICTION. LEGEND NEW ITEM RELOCATED ITEM EXISTING ITEM TO REMAIN OR FURTURE USE STARBVCKSU 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 WREGISDI 7STATE TIN LEE HILL OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O '— W Q Q O co c� Q w 0 co z LU O Z 0 U) 0 z0 Qoo U U W O LU ° LU O ° 0 0- W oo Il rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: ENLARGED FF & E PLAN ENLARGED FURNITURE, FIXTURES AND EQUIPMENT PLAN scale: 1 /2" = V-0" SCALE: AS SHOWN SHEET NUMBER: 1102 10'-5" 4'-3" 4'-8" i o - 0 zo 3 ) Lr L I/ L� L✓ L✓ 3 4 4 X0001x IV,: o O C 20352 1 2 L C C L� L__ ___JL� F 0 0 O 71 3'- 7 1 /2" 1 CLEAR a KEYED NOTES 1. INSTALL CASEWORK, COUNTERTOPS, SHELVES, CUBBIES, FINISHES, TRIM AND TABLE TOPS THROUGHOUT. 2. ALL COUNTERTOPS SHALL BE INSTALLED AT 2'-10" (860 MM) MAXIMUM A.F.F. MAX. 3. VARIABLE WIDTH FILLER CABINET / COUNTERTOP REQUIRED TO FILL GAP (FIELD VERIFY DIMENSION). FILLER PANEL AND COUNTERTOP SHALL BE SCRIBED AND FIELD CUT TO FIT. 4. FLOOR DRAIN BELOW. CASEWORK MANUFACTURER TO COORDINATE DESIGN TO INSURE THIS AREA IS READILY ACCESSIBLE FOR CLEANING AND FREE OF COUNTERTOP SUPPORT. a GENERAL NOTES A. GENERAL CONTRACTOR TO NOTIFY CONSTRUCTION MANAGER IMMEDIATELY IF A DISCREPANCY EXISTS BETWEEN CASEWORK SHOP DRAWINGS, EXISTING SITE CONDITIONS, ARCHITECTURAL DRAWINGS OR BUILT FIXTURES. ALL DIMENSIONS SHALL BE FIELD VERIFIED BY G.C. B. STARBUCKS CONSTRUCTION MANAGER TO COORDINATE AND SCHEDULE CASEWORK DELIVERY DATE. GENERAL CONTRACTOR TO CONFIRM CASEWORK DELIVERY DATE WITH CASEWORK MANUFACTURER AT FOUR (4) WEEKS PRIOR AND THEN ONE (1) WEEK PRIOR TO SCHEDULED DATE OF DELIVERY. C. STARBUCKS CONTRACTS DIRECTLY WITH CASEWORK VENDOR TO SUPPLY CASEWORK LISTED IN THE CASEWORK SCHEDULE, UNLESS OTHERWISE NOTED. D. CASEWORK VENDOR TO PROVIDE COMPLETE SHOP DRAWINGS AND INSTALLATION PACKAGE TO GENERAL CONTRACTOR TO FACILITATE PROPER INSTALLATION. E. ALL CASEWORK BOX BASES SHALL BE SET AND LEVELED USING 1/4" (6 MM) NON -ABSORBENT PLASTIC SHIMS PROVIDED BY CASEWORK VENDOR. F. SEE INTERIOR FINISH ELEVATIONS AND SCHEDULES FOR LOCATION AND TAGGING OF WALL TREATMENTS BY CV AND OTHERS. G. SEE REFLECTED CEILING PLAN FOR ABOVE BAR SOFFIT LOCATIONS. H. REFERENCE PLUMBING AND ELECTRICAL PLANS FOR PLACEMENT OF ELECTRICAL, DATA AND PLUMBING ON FRONT AND BACKLINE OF BAR. LEGEND INDICATES STAINLESS STEEL (SST) COUNTERTOP INDICATES SOLID SURFACE (SS) COUNTERTOP DATUM POINT STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El 7MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O - , W Q O 00 Q VJ W 0 w 0 LU O Z � 07 0 z0 Qoo U U W O LU ° LU O ° 0 0- W oo a- rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: CASEWORK PLAN CASEWORK PLAN scale: 1 /4" = V-0" SCALE: AS SHOWN SHEET NUMBER: 1103 "v "v iO ENLARGED RCP Scale: 1 /2" = V-0" LEGEND ELEVATION DATUM TRACK LIGHTING STRIP LIGHTING OQ PENDANT LIGHT ® RECESSED CAN LIGHT TROFFER WALL SCONCE EXIT SECURITY LIGHT 0 MUSIC SYSTEM RECESSED SPEAKER SUPPLY AIR RETURN AIR KEYED NOTES 1. GWB SOFFIT WITH SMOOTH FINISH (PAINT AS SCHEDULED). 2. GWB CEILING. PAINT CEILING DIFFUSERS SAME COLOR AS CEILING. 3. WASHABLE CEILING TILE LOCATED IN BACK OF HOUSE AND ABOVE CAFE BAR (IF APPLICABLE). 4. OPEN TO STRUCTURE ABOVE. PAINT BOTTOM OF DECK AND TRUSSES AS SCHEDULED. 5. RECESSED SPEAKER. 6. EXISTING ROOF LADDER AND ACCESS HATCH. 7. SECURITY CAMERA MOUNTED TO CEILING IN OPEN CONDITION. INSTALL AT SAME HEIGHT AS ADJACENT STORE LIGHTING. 8. EXISTING SECURITY CAMERA. 9. EXISTING ACT TO REMAIN. 10. PATCH & REPAIR CEILING AS NEEDED. 11. CHASE FOR ICE MACHINE ACCESS. (SEE 2/ENLARGED RCP) 12. ICE DIVERTER PATH FROM ICE MACHINE TO OVERHEAD ICE DISPENSER AT CBE. 13. LINEAR DIFFUSERS. CAFE 1 2 ENGINE DRIVE THRU 1 2 ENGINE 1 2 ENGINE 1 2 WORKROOM O WORKROOM O WORKROOM CAFE 1 2 CAFE U CAFE -VESTIBULE 1 2 RESTROOM 2 1 2 RESTROOM 1 1 2 GENERAL NOTES A. REFERENCE LOW VOLTAGE PLAN SHEET AND ELECTRICAL DRAWINGS. B. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI -RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED IN GWB SOFFIT OVER FRONT BAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT. GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO STARBUCKS' CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO INSTALLATION. C. LEAVE TEN (10) ADDITIONAL RETAIL CEILING TILES TO MATCH RETAIL CEILING PAINT COLOR ABOVE THE WORKROOM CEILING AT MANAGER'S DESK FOR FUTURE USE. D. PROVIDE GROMMET AT ACOUSTIC CEILING PENETRATIONS FOR FIXTURES OF SUPPORTS. E. HEATING, VENTILATING AND AIR CONDITIONING SHOWN ON THIS PLAN PROVIDED FOR REFERENCE ONLY. SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. F. DIFFUSERS AND RETURNS IN ACOUSTICAL CEILING TILE TO BE CENTERED IN TILE AND PAINTED TO MATCH ADJACENT FINISHES (TYP.). G. PAINT ALL EXPOSED HVAC DUCTS, HVAC DIFFUSERS, LIGHT TRIM RINGS, PIPING, CONDUIT AND JUNCTION BOXES THE SAME COLOR AS SPECIFIED ON SURROUNDING CEILING OR SOFFIT UNLESS OTHERWISE NOTED. TYPICAL THROUGHOUT RETAIL AREA OF STORE. H. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. I. DATA CABLING ABOVE HEAD SHALL BE IN PLENUM WHEN AVAILABLE. J. DATA CABLING AT EXPOSED CEILING SHALL BE INSTALLED IN METAL CONDUIT OR PER LOCAL CODE REQUIREMENT. WORKROOM O STARBVCKSU 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El C TIN LEE HILL OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O Ir- 06 Q Q O 00 O C/) Q w p co Z LU O Z 0 Uj o z 0 a p Z U U W O LU 0 LU O 000p 0 W o_ rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: REFLECTED CEILING PLAN SCALE: AS SHOWN REFLECTED CEILING PLAN Scale: 1 /4" = V-0" SHEET NUMBER: 1104 KEYED NOTES 1. GWB SOFFIT WITH SMOOTH FINISH (PAINT AS SCHEDULED). 2. GWB CEILING. PAINT CEILING DIFFUSERS SAME COLOR AS CEILING. 3. EXISTING WASHABLE CEILING TILE LOCATED IN BACK OF HOUSE AND ABOVE CAFE BAR (IF APPLICABLE). 4. OPEN TO STRUCTURE ABOVE. PAINT BOTTOM OF DECK AND TRUSSES AS SCHEDULED. 5. EXISTING ROOF LADDER AND ACCESS HATCH. 6. RECESSED ACCESS HATCH. PAINT TO MATCH ADJACENT FINISH. 7. SECURITY CAMERA MOUNTED TO CEILING IN OPEN CONDITION. INSTALL AT SAME HEIGHT AS ADJACENT STORE LIGHTING. 8. EXISTING SECURITY CAMERA. 9. CENTER PENDANT TO WINDOW MULLION OR WINDOW PANE. 10. ICE DIVERTER PATH FROM ICE MACHINE TO OVERHEAD ICE DISPENSER AT CBE. GENERAL NOTES A. REFERENCE LOW VOLTAGE PLAN SHEET AND ELECTRICAL DRAWINGS. B. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI -RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED IN GWB SOFFIT OVER FRONT BAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT. GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO STARBUCKS' CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO INSTALLATION. C. LEAVE TEN (10) ADDITIONAL RETAIL CEILING TILES TO MATCH RETAIL CEILING PAINT COLOR ABOVE THE WORKROOM CEILING AT MANAGER'S DESK FOR FUTURE USE. D. PROVIDE GROMMET AT ACOUSTIC CEILING PENETRATIONS FOR FIXTURES OF SUPPORTS. E. HEATING, VENTILATING AND AIR CONDITIONING SHOWN ON THIS PLAN PROVIDED FOR REFERENCE ONLY. SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. F. DIFFUSERS AND RETURNS IN ACOUSTICAL CEILING TILE TO BE CENTERED IN TILE AND PAINTED TO MATCH ADJACENT FINISHES (TYP.). G. PAINT ALL EXPOSED HVAC DUCTS, HVAC DIFFUSERS, LIGHT TRIM RINGS, PIPING, CONDUIT AND JUNCTION BOXES THE SAME COLOR AS SPECIFIED ON SURROUNDING CEILING OR SOFFIT UNLESS OTHERWISE NOTED. TYPICAL THROUGHOUT RETAIL AREA OF STORE H. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. I. DATA CABLING ABOVE HEAD SHALL BE IN PLENUM WHEN AVAILABLE. J. DATA CABLING AT EXPOSED CEILING SHALL BE INSTALLED IN METAL CONDUIT OR PER LOCAL CODE REQUIREMENT. LEGEND ELEVATION DATUM TRACK LIGHTING STRIP LIGHTING REFLECTED CEILING LIGHTING PLAN I. PENDANT LIGHT Scale: 1 /4" = V-0" ® RECESSED CAN LIGHT TROFFER Q WALL SCONCE C_� EXIT SECURITY LIGHT MUSIC SYSTEM RECESSED SPEAKER SUPPLY AIR RETURN AIR STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2021.10.22 ARCHITECT OF RECORD !A GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El C TIN LEE HILL OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O Irx W Q Q O 00 VJ � w 0 LU O Z Ir 07 0 z0 Qoo U U W O LU ° LU O ° 0 0 W 00 o_ rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: REFLECTED CEILING PLAN - LIGHTING SCALE: AS SHOWN REFLECTED CEILING LIGHTING PLAN Scale: 1 /4" = V-0" SHEET NUMBER: 1105 KEYED NOTES 1. TILE START POINT WHERE INDICATED. 2. ALIGN TILE TRANSITION WITH FACE OF ADJACENT WALL/SURFACE WHERE INDICATED. 3. FLOOR SINK LOCATION. SEE BUILDING FLOOR PENETRATION PLAN ON SHEET A102 AND PLUMBING FOR ADDITIONAL INFORMATION. 4. RECESSED ELECTRICAL. SEE BUILDING FLOOR PENETRATION PLAN ON SHEET A102 AND ELECTRICAL FOR ADDITIONAL INFORMATION. 5. RECESSED WALK -OFF MAT AT ENTRY. SEE INTERIOR DETAIL SHEETS FOR TRANSITION. 6. MOP SINK WHERE INDICATED. SEE PLUMBING PLANS FOR MORE INFORMATION. GENERAL NOTES A. WORKROOM TO BE FINISHED PER LOCAL CODE REQUIREMENTS. B. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON -TOXIC, NON -ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI -GLOSS OR HIGH -GLOSS FINISH. C. STARBUCKS TO SUPPLY FLOORING AND BASE FOR FRONT AND BACK OF HOUSE AS NOTED IN SCHEDULES. GENERAL CONTRACTOR TO INSTALL. GENERAL CONTRACTOR TO SUPPLY WORKROOM TILE AND BASE AND INSTALL. GENERAL CONTRACTOR TO SUPPLY AND INSTALL MORTAR, ADHESIVE, AND GROUT. GENERAL CONTRACTOR TO INSPECT ALL TILES AND REJECT DAMAGED OR SUBSTANDARD TILES PRIOR TO INSTALLATION. 7. UNDERGROUND GREASE INTERCEPTOR. SEE PLUMBING D. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. DRAWINGS FOR ADDITIONAL INFORMATION. E. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. LEGEND INDICATES TILE START POINT INDICATES BASE FINISH TRANSITION POINT — — INDICATES ECOGRIP BASE BASE DID: 19795 INDICATES TILE BASE (2) BASE DID: 20269 � INDICATES METAL BASE (3) BASE DID: MT-0011 ---0--- INDICATES NO BASE AT BRICK WALL BASE DID: - ECOGRIP FLOORING POLYVINIL FLOORING - PEWTER DID:19795 WALK -OFF MAT RECYCLED TIRE - CHARCOAL DID:12243 TILE FRENCH CLAY - CAFE - 24x24 IN DID:20262 STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 WRIGISDI 7STATE TIN LEE HILL OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 06 Q O 3: 00 v, VJ rnLU 0 O Cw c Z IY 07 0 z0 < Z U U W O LU ° LU O ° 0 o_ W oo a- rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: FLOOR FINISH PLAN FLOOR FINISH PLAN scale: 1 /4" = V-0" SCALE: AS SHOWN SHEET NUMBER: 1106 KEYED NOTES 1. BLACK FRP UP TO UNDERSIDE OF COUNTER BEHIND CASEWORK WHERE WALL IS VISIBLE. 2. FOR RESTROOM AND ENGINE CENTER FULL TILE ON SHORT WIDTH OF ROOM. 3. SEE INTERIOR FINISH ELEVATIONS (I201 AND 1202) FOR WALL FINISHES IN CAFE AND ENGINE. 4. BLACK OUT FILM ADDED TO INSIDE FACE OF GLASS GENERAL NOTES A. WORKROOM TO BE FINISHED PER LOCAL CODE REQUIREMENTS. B. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON -TOXIC, NON -ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI -GLOSS OR HIGH -GLOSS FINISH. C. STARBUCKS TO SUPPLY FLOORING AND BASE FOR FRONT AND BACK OF HOUSE AS NOTED IN SCHEDULES. GENERAL CONTRACTOR TO INSTALL. GENERAL CONTRACTOR TO SUPPLY WORKROOM TILE AND BASE AND INSTALL. GENERAL CONTRACTOR TO SUPPLY AND INSTALL MORTAR, ADHESIVE, AND GROUT. GENERAL CONTRACTOR TO INSPECT ALL TILES AND REJECT DAMAGED OR SUBSTANDARD TILES PRIOR TO INSTALLATION. D. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. E. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. LEGEND INDICATES FULL HEIGHT WOOD VENEER AA PANEL. SEE INTERIOR ELEVATIONS FOR SPECIFIC APPLICATION TYPE. REFER TO DETAILS FOR FURTHER INFORMATION. DID: WD0073 INDICATES WALL TILE TO HEIGHT PER INTERIOR ELEVATIONS. WALL TILE DID: 22819 BLACK FRP BELOW COUNTER — — INDICATES FULL HEIGHT FRP DID:11469 INDICATES FULL HEIGHT THIN BRICK D INDICATES FULL HEIGHT WALLCOVERING DID:X0002 INDICATES WALL TILE TO HEIGHT PER F INTERIOR ELEVATIONS. PAINT WHERE TILE ENDS TO CEILING. WALL TILE DID: 20230 PAINT DID: X7504 INDICATES FINISH TRANSITION POINT STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !jm GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 93351 REG MAM LEE HILL ITE OF WAS14INGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 06 QC)�y� KJ m '� VJ rn 0 W O Cw C Z zp Qoz U U W O w w O 0 �W a- C W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: WALL FINISH PLAN WALL FINISH PLAN / scale 1 SCALE: AS SHOWN SHEET NUMBER: 1107 CAFE 4 scale: 3/8" = V-0" Lscale: 3/8" = V-0" KEYED NOTES 1. PENDANT LIGHT FIXTURE (SEE REFLECTED CEILING PLAN ON SHEET 1103 AND LIGHTING PLAN ON SHEET E102 FOR ADDITIONAL INFORMATION). 2. NEW ARTWORK AS INDICATED GC TO INSTALL WITH SURFACE MOUNTED FRENCH CLEATING AS REQUIRED. 3. EXISTING STOREFRONT, DOORS AND WINDOWS TO REMAIN. 4. EXISTING ROLLER SHADE TO REMAIN. LEGEND F_ —1 INDICATES WALL BLOCKING. BLOCKING TO BE PROVIDED AS REQUIRED TO SUPPORT WALL ATTACHMENTS. EXTEND BLOCKING 4" (100mm) L_ — — — J BEYOND EDGE OF ATTACHMENTS. GENERAL NOTES A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND EQUIPMENT (FF & E) SCHEDULES ON SHEET 1601. B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH ARTWORK/GRAPHICS FOR PROPER INSTALLATION. C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE INDICATED. D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE: 1. WOODS AND METAL SURFACES SHALL BE SEMI -GLOSS OR EQUAL. 2. ACCENT AND TRIM PAINTS TO BE SEMI -GLOSS OR EQUAL. A. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL. 3. PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI -GLOSS OR EQUAL. E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL ACCOUNT COLOR CODE WHEN ORDERING PAINTS. F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON- TOXIC, NON -ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI- GLOSS OR HIGH GLOSS FINISH. G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE SEALED. H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON SHEET 1102 FOR CASEWORK FINISH MATERIAL INFORMATION. I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F. L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING BACK BAR TILE. M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL FINISHES. STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !A GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El C TIN LEE HILL OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O Ir- 06 Q O 3: 00 v, VJ rnLU 0 O Cw c Z 0r 07 0 z0 < Z U U W O LU ° LU O 0 ° 0- W oo o_ rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: INTERIOR FINISH ELEVATIONS SCALE: AS SHOWN SHEET NUMBER: 1201 CAFE 6 Scale: 3/8" = V-0" VESTIBULE 1 VESTIBULE 2 3 Scale: 3/8" = 1'-01, 2 Scale: 3/8" = V-0" KEYED NOTES 1. PENDANT LIGHT FIXTURE (SEE REFLECTED CEILING PLAN ON SHEET 1103 AND LIGHTING PLAN ON SHEET E102 FOR ADDITIONAL INFORMATION). 2. ATTACH MENU BOARDS PER INSTALLATION DETAILS. 3. WALL PANELS TO BE PROVIDED BY CASEWORK VENDOR. SEE 1602 FOR INTERIOR FINISH SCHEDULES. 4. NEW ARTWORK AS INDICATED GC TO INSTALL WITH SURFACE MOUNTED FRENCH CLEATING AS REQUIRED. GENERAL NOTES A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND EQUIPMENT (FF & E) SCHEDULES ON SHEET 1601. B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH ARTWORK/GRAPHICS FOR PROPER INSTALLATION. C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE INDICATED. D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE: 1) WOODS AND METAL SURFACES SHALL BE SEMI -GLOSS OR EQUAL. 2) ACCENT AND TRIM PAINTS TO BE SEMI -GLOSS OR EQUAL. a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL. 3) PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI -GLOSS OR EQUAL. E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL ACCOUNT COLOR CODE WHEN ORDERING PAINTS. F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON -TOXIC, NON -ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI -GLOSS OR HIGH GLOSS FINISH. G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE SEALED. H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON SHEET 1102 FOR CASEWORK FINISH MATERIAL INFORMATION. I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F. L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING BACK BAR TILE. M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL FINISHES. STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !A GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 WRIGISDI CSTATE TIN LEE HILL OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O Ir- 06 Q O 3: 00 v, VJ rnLU 0 O Cw c Z 0r 07 0 z0 < Z U U W O LU ° LU O 0 ° 0- W oo o_ rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: INTERIOR FINISH ELEVATIONS SCALE: AS SHOWN CAFE 1 - FRONT BAR CUSTOMER FACING Scale: 3/8" = V-0" SHEET NUMBER: 1202 5 DRIVE THRU 1 Scale: 3/8" = 1'-0" DRIVE THRU 2 4 Scale: 3/8" = V-0" C" 3 DRIVE THRU 3 Scale: 3/8" = V-0" KEYED NOTES 1. PENDANT LIGHT FIXTURE (SEE REFLECTED CEILING PLAN ON SHEET 1105 AND LIGHTING PLAN ON SHEET E102 FOR ADDITIONAL INFORMATION). 2. ATTACH MENU BOARDS PER INSTALLATION DETAILS. 3. WALL PANELS TO BE PROVIDED BY CASEWORK VENDOR. SEE 1602 FOR INTERIOR FINISH SCHEDULES. 4. EXISTING STOREFRONT, DOORS AND WINDOWS TO REMAIN. 5. EXISTING ROLLER SHADE TO REMAIN. 6. TILE START POINT AT TOP OF LIGHT COVE. 7. ICE DROP ACESS PANEL. GENERAL NOTES A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND EQUIPMENT (FF & E) SCHEDULES ON SHEET 1601. B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH ARTWORK/GRAPHICS FOR PROPER INSTALLATION. C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE INDICATED. D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE: 1) WOODS AND METAL SURFACES SHALL BE SEMI -GLOSS OR EQUAL. 2) ACCENT AND TRIM PAINTS TO BE SEMI -GLOSS OR EQUAL. a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL. 3) PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI -GLOSS OR EQUAL. E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL ACCOUNT COLOR CODE WHEN ORDERING PAINTS. F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON -TOXIC, NON -ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI -GLOSS OR HIGH GLOSS FINISH. G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE SEALED. H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON SHEET 1102 FOR CASEWORK FINISH MATERIAL INFORMATION. I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F. L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING BACK BAR TILE. M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL FINISHES. LEGEND F_ —1 INDICATES WALL BLOCKING. BLOCKING TO BE PROVIDED AS REQUIRED TO SUPPORT WALL ATTACHMENTS. EXTEND BLOCKING 4" (100mm) J BEYOND EDGE OF ATTACHMENTS. -l!l WALL TILE START POINT DATUM STARBUCKS' 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 06 Q O 3: W T VJ VJ rn 0 LU O Cw c Z 0r 0 07 z0 Qoo U U W O LU ° LU O 0 ° 0- W oo a- rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: INTERIOR FINISH ELEVATIONS SCALE: AS SHOWN ENGINE Scale: 3/8" = V-0" 1 - BACK BAR FACING (1)_ENGINE 2 scale: 3/8" = V-0" SHEET NUMBER: 1203 ENGINE 3 - FRONT BAR BARISTA FACING KEYED NOTES GENERAL NOTES 1. PENDANT LIGHT FIXTURE (SEE REFLECTED CEILING PLAN A. FOR GRAPHICS SCHEDULE, REFER TO THE ON SHEET 1103 AND LIGHTING PLAN ON SHEET E102 FOR FURNITURE, FIXTURES, AND EQUIPMENT (FF & E) ADDITIONAL INFORMATION). SCHEDULES ON SHEET 1601. B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH ARTWORK/GRAPHICS FOR PROPER INSTALLATION. C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE INDICATED. D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE: 1. WOODS AND METAL SURFACES SHALL BE SEMI -GLOSS OR EQUAL. 2. ACCENT AND TRIM PAINTS TO BE SEMI -GLOSS OR EQUAL. A. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL. 3. PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI -GLOSS OR EQUAL. E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL ACCOUNT COLOR CODE WHEN ORDERING PAINTS. F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON- TOXIC, NON -ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI- GLOSS OR HIGH GLOSS FINISH. G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE SEALED. H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON SHEET 1102 FOR CASEWORK FINISH MATERIAL INFORMATION. I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F. L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING BACK BAR TILE. M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL FINISHES. LEGEND F_ —1 INDICATES WALL BLOCKING. BLOCKING TO BE PROVIDED AS REQUIRED TO SUPPORT WALL ATTACHMENTS. EXTEND BLOCKING 4" (100mm) L J BEYOND EDGE OF ATTACHMENTS. ENGINE 4 - BARISTA FACING STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El 7MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 06 Q O 00 v, VJ rn 0 LU O Cw c Z Ir 07 0 z0 < Z U U W O LU ° LU O 0 ° 0- W oo a- rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: INTERIOR FINISH ELEVATIONS SCALE: AS SHOWN scale: 3/8" = V-0" scale: 3/8" = V-0" SHEET NUMBER: 1204 WORKROOM 9 scale: 3/8" = V-0" WORKROOM 7 scale: 3/8" = V-0" 3 (�A�WORKROOM 3/8" = V-0" 9 WORKROOM 2 is EC (�AORKROOM 8 scale: 3/8" = 1'-0" LEGEND INDICATES WALL BLOCKING. BLOCKING TO BE PROVIDED AS REQUIRED TO SUPPORT WALL ATTACHMENTS. EXTEND BLOCKING 4" (100mm) BEYOND EDGE OF ATTACHMENTS. Q 11469 Q 11469 Q 11469 KEYED NOTES 1. ELECTRICAL PANELS (SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION). 2. NEW DATA EQUIPMENT. 3. EXISTING ROOF LADDER. OPEN TO BEYOND 1 scale: 3/8" = V-0" GENERAL NOTES A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND EQUIPMENT (FF & E) SCHEDULES ON SHEET 1601. B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH ARTWORK/GRAPHICS FOR PROPER INSTALLATION. C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE INDICATED. D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE: 1. WOODS AND METAL SURFACES SHALL BE SEMI- GLOSS OR EQUAL. 2. ACCENT AND TRIM PAINTS TO BE SEMI -GLOSS OR EQUAL. a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL. 3. PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI -GLOSS OR EQUAL. E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL ACCOUNT COLOR CODE WHEN ORDERING PAINTS. F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON- TOXIC, NON -ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI -GLOSS OR HIGH GLOSS FINISH. G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE SEALED. H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON SHEET 1102 FOR CASEWORK FINISH MATERIAL INFORMATION. I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F. L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING BACK BAR TILE. M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL FINISHES. WORKROOM 4 Scale: 3/8" = V-0" N 2. 2 O� o o OPEN TO BEYOND o - o � ih CV ihmill B 19795 MANAGER'S OFFICE STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El C TIN LEE HILL OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT C) Irx W Q Q O 00 O U) Q U) U) 0 w 0 co z LU O Z 0 U) o z0 Qoo U U Ll.l O LU ° LU O ° 0- W 000 a- (3) W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: INTERIOR FINISH ELEVATIONS SCALE: AS SHOWN SHEET NUMBER: 1205 scale: 3/8" = V-0" scale: 3/8" = V-0" 0 10 RcalESTROOM 1 - VIEW A se: 318" = 1'-0" 0 6 RESTROOM 2 - VIEW A scae: 3/8" = 1'-0" a I KEYED NOTES 1. 60" (1700MM) ACCESSIBLE TURNING RADIUS. 2. 30" (760MM) X 48" (1320MM) CLEAR FLOOR SPACE. 3. WATER CLOSET CLEAR FLOOR SPACE. 4. BABY CHANGING FIXTURE. 5. TILE START POINT. FULL TILE ABOVE BASE COVE. CENTER FULL TILE ON WALL (HORIZONTALLY). 6. WALL MOUNTED LAVATORY INSTALLED WITH SUPPORT CARRIER AND INSULATED BOOT AT EXPOSED PIPES. 7. CENTER MIRROR OVER LAVATORY. MOUNT AT 40" (1015MM) MAX. TO BOTTOM EDGE OF REFLECTIVE SURFACE. 8. COAT HOOK. MOUNT AT CENTERLINE OF DOOR 9. CENTER SCONCE LIGHTING OVER MIRROR (SEE ELECTRICAL). 10. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ALL SENSORS AND CONTROLS (TYPICAL). GENERAL NOTES A. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. B. ALL DIMENSIONS ARE TO BE TAKEN FROM A DESIGNATED DATUM POINT. C. DIMENSIONS ARE TO FACE OF FINISHED SURFACE UNLESS OTHERWISE NOTED. D. DIAPER CHANGING STATION IS TO BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. UNIT IS TO BE FASTENED TO STRUCTURE AT ALL SIX CHASSIS ATTACHMENT POINTS. E. LOCATE DIAPER CHANGING STATION AS SHOWN TO ALLOW NECESSARY CLEARANCE FOR OPERATION OF ALL RESTROOM FIXTURES. LOCATION SHALL NOT IMPEDE ACCESS, EGRESS, OR DOOR SWING. F. ALL RESTROOM ACCESSORY MOUNTING HEIGHTS AND CLEARANCES SHALL COMPLY WITH THE ACCESSIBILITY REQUIREMENTS OF THE LOCAL JURISDICTION. 9 R�F_ ROOM 1- VIEW B 8 RESTROOM 1- VIEW C 7�S--,F_ OM 1- VIEW D LEGEND scal'-0" scale: 3/8" = V-0' .11 n 1 101, 5 RESTROOM 2 - VIEW B scale: 3/8" = 1'-0" ENLARGED RESTROOM 1 PLAN i 4 RESTROOM 2 - VIEW C scale: !, = 1'-0" 3 RESTROOM 2 - VIEW D Sc-!' = 1'-0" 36" MIN 12" 24" MIN MIN CD d M H M 0 0, M � � I 1'-6" INDICATES WALL BLOCKING. BLOCKING TO BE I PROVIDED AS REQUIRED TO SUPPORT WALL I ATTACHMENTS. EXTEND BLOCKING 4" (100mm) L BEYOND EDGE OF ATTACHMENTS. 39" -40" q 12" 42" MIN °r° MAX � a e CO d d M 0 i Z Z (y) M 7" MIN-' .- 'j 9" MAX li- TOILET FRONT ELEVATION TOILET SIDE ELEVATION 1'-6" PREFERE 1'-3" MIN 8" > LU g - UQ - - M o - � CD O ~ CV - C0 LL - � � N _NN HAND SINK HAND SINK SIDE ELEVATION FRONT ELEVATION NV 1 1`1 1`1In ri ,,,--INSTALL HEIGHT PER MANUFACTURER'S INSTRUCTION DIAPER CHANGING STATION SIDE AND FRONT ELEVATIONS M ELECTRIC HAND DRYER FRONT ELEVATION COAT HOOK 1 MOUNTING HEIGHTS FOR RESTROOM ACCESSORIES scale: 3/8" = V-0" STARBVCKSU 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !ja GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS El C TIN LEE HILL OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT C) r 06 Q Q O 00 VJ U) 0 w 0 co z LU O Z IY 07 0 z0 Qoo U U Ll.l O LU LU 0 0 d 0 00 d (3) w STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: RESTROOM PLAN & ELEVATIONS SCALE: AS SHOWN Scale: 1 /2" = V-0" SHEET NUMBER: 1401 CEMENTITOUS BACKER BOARD WALL TYPE PER LEGEND CONTINUOUS WATERPROOF MEMBRANE. EXTEND 12" (305mm) UP WALL. SEALANT TO MATCH ADJACENT WALL FINISH 6" TILE BASE PER SCHEDULE. d ADHERE TO WALL PER MFR'S RECOMMENDATIONS. 1/4" (6MM) RADIUS AT COVED BASE FINISH FLOOR PER SCHEDULE CONTINUOUS WATERPROOF MEMBRANE APPLIED TO SUBFLOOR. EXTEND EDGE TO 12" (305mm) OFFSET FROM WALL. CONCRETE SLAB WALL TYPE PER LEGEND CEMENTITOUS BACKER BOARD CONTINUOUS WATERPROOF MEMBRANE. EXTEND 12" (305mm) UP WALL. WALL TILE PER SCHEDULE. ADHERE TO WALL PER MFR'S RECOMMENDATIONS. COVED TILE BASE PER SCHEDULE. ADHERE TO WALL PER MFR'S RECOMMENDATIONS. 1/4" (6MM) RADIUS AT COVED BASE FINISH FLOOR PER SCHEDULE CONTINUOUS WATERPROOF MEMBRANE APPLIED TO SUBFLOOR. EXTEND EDGE TO 12" (305mm) OFFSET FROM WALL. CONCRETE SLAB STOREFRONT DOOR WITH THRESHOLD WALK -OFF MAT PER SCHEDULE STAINLESS STEEL ANGLE TILE FLOOR PER SCHEDULE PER TILE IF1-54 �� WATERPROOF MEMBRANE ON WOOD SUBFLOOR ONLY 14�''L6� BASE @ WOOD PANEL _ 13 COVED TILE BASE @ TILED WALL 12 TRANSITION - TILE TO WALK OFF MAT = V-0" scale: 6" = 1'-0" scale: 6" = 1'-0" WALL TYPE PER LEGEND SEALANT TO MATCH ADJACENT WALL FINISH COVED TILE BASE PER SCHEDULE. ADHERE TO WALL PER MFR'S RECOMMENDATIONS. 1/4" (6MM) RADIUS AT COVED BASE FINISH FLOOR PER SCHEDULE CONCRETE SLAB INTEGRAL TILE BASE AT WALL DECO -GRIP AT MOP SINK MOP SINK 1/4" (6MM) ECO-GRIP SPEEDFLEX ECO-GRIP FLOORING ECO-GRIP EPDXY ADHESIVE CONCRETE SLAB SCHLUTER TRANSITION STRIP TILE FLOOR PER PLAN CONCRETE SLAB ECO-GRIP COLOR MATCHED SPEEDFLEX. SLOPE TO FLOOR SINK ECO-GRIP EPDXY ADHESIVE ECO-GRIP g FLOORING co 7t - SLOPE TO FLOOR SINK 1/8" (3MM) GAP BETWEEN ECO-GRIP FLOORING AND FIXTURE EXISTING FLOOR SINK ASSEMBLY d - d CONCRETE SLAB ECO-GRIP TO FLOOR SINK TRANSITION scale: 12" = V-0" 1/4" ECO-GRIP SPEEDFLEX ECO-GRIP FLOORING SLOPE <_�� V SUBSTRATE MAY REQUIRE SLOPING ECO-GRIP EPDXY TO ADJUST HEIGHT SO THAT ECO-GRIP ADHESIVE AND ADJACENT FLOOR ARE FLUSH =THISDETAIL APPLIES TO FLOOR AREAS BELOW FIXTURES AND EQUIPMENT ONLY ECO-GRIP TO TILE TRANSITION (FIXTURES & EQUIPMENT scale: 6" = 1'-0" S. 12" = 1'-0" ��� scale: 12" = 1'-0" - THINSET FRP WALL WALL AND WALL AND COVERING WALL AND SHEATHING - WALL TILE PER PLAN SHEATHING SHEATHING PER PLAN / PER PLAN STAINLESS STAPLE PER PLAN STAINLESS STAPLE OR POWDER COATED OR POWDER COATED FASTENER FASTENER ECO-GRIP ECO-GRIP ECO-GRIP BASE SEALANT - ECO-GRIP BASE SEALANT CAP. COLOR TO CAP. COLOR TO MATCH ECO-GRIP MATCH ECO-GRIP FLOORING - FLOORING ECO-GRIP SEALANT ECO-GRIP Z ECO-GRIP EPDXY EPDXY ADHESIVE ECO-GRIP ADHESIVE EPDXY `r ADHESIVE CONCRETE CONCRETE - SLAB 1/4" SLAB co 1/4" (6MM) 1/4" (6MM) (6MM) ROUTED ROUTED ECO-GRIP ROUTED FLOORING COVE COVE FLOORING COVE 4 STAINLESS STAPLE OR POWDER COATED STEELFASTENER ECO-GRIP BASE CAP. COLOR TO MATCH ECO-GRIP FLOORING CABINET ABOVE CABINET LEG ECO-GRIP FLOORING CONCRETE SLAB ECO-GRIP SEALANT ECO-GRIP C° EPDXY ADHESIVE ECO-GRIP COLOR MATCHED SPEEDFLEX } ECO-GRIP FLOORING - g ECO-GRIP EPDXY `9 ADHESIVE 1/8" (3MM) GAP BETWEEN ECO-GRIP FLOORING AND FIXTURE STAINLESS STEEL FLANGE FLOOR SINK GRATE d;7;4, CONCRETE SLAB ' ECO-GRIP TO FLOOR SINK TRANSITION scale: 12" = V-0" 16 GA. 2 1/4" (57MM) WIDE STAINLESS STEEL TRANSITION STRIP SEALANT CONCRETE SLAB TILE FLOOR PER PLAN STAINLESS FASTENER ROUTE OUT FLOORING TO DEPTH OF TRANSITION STRIP ECO-GRIP FLOORING _ ECO-GRIP ECO-GRIP EPDXY SEALANT ADHESIVE LEAD ANCHOR SUBSTRATE MAY REQUIRE SLOPING TO ADJUST HEIGHT SO THAT ECO-GRIP AND ADJACENT FLOOR ARE FLUSH ECO-GRIP TO TILE TRANSITION AT FOOT TRAFFIC AREA 6 scale: 12" = V-0" CABINET FINISH FACE STAINLESS STAPLE OR POWDER COATED FASTENER ECO-GRIP BASE 6" (150MM) +/- TYP. A.F.F. CAP. COLOR TO MATCH ECO-GRIP FLOORING ECO-GRIP CABINET TOE -KICK OVERHANG SEALANT STAINLESS STAPLE OR POWDER INSTALL CASEWORK COATED FASTENER BASE PRIOR TO - ECO-GRIP BASE CAP. COLOR TO ECO-GRIP FLOORING MATCH ECO-GRIP FLOORING CONCRETE SLAB INSTALL CASEWORK BASE PRIOR TO ECO-GRIP FLOORING ECO-GRIP CONCRETE SLAB FLOORING ECO-GRIP ECO-GRIP 1/4" (6MM) EPDXY FLOORING ROUTED ADHESIVE 1/4" (6MM) COVE ROUTED COVE STARBUCKS U 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2021.10.22 ARCHITECT OF RECORD !imGRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS D MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O W Q Q O 00 U) Q �^^ VJ 0 LLI co LU O 2 Z � 0 z0 < Z U I---Ll.l O W W 0 0Y d W 0Y 00 d W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: INTERIOR DETAILS - FLOORS SCALE: AS SHOWN ECO-GRIP - BASE CAP WITH TILED WALL scale: 6" = V-0" ECO-GRIP - BASE CAP WITH FRP scale: 6" = V-0" ECO-GRIP - BASE AT CABINET WITH LEGS scale: 6" = V-0" ECO-GRIP BASE AT CABINET SIDE scale: 6" = V-0" ECO-GRIP - BASE AT CABINET FRONT Scale: 6" = V-0" SHEET NUMBER: 1501 0 N 12' - 0 1/2" (3670.3 MM MIN. BLOCKING (VIF)) EQ. 11' - 0 1/2" (3364.2MM 3 SCREENS) 3' - 8 1 /4" 3' - 8 1 /4" I 2'-9" ✓ 2'-9" d w L I w I O � w z I r-- -- Z I I -- Y I I O in I I I I w u--- — I L-------- 6" MIN. OFFSET (TYP.) 4" 4" 1 4" 6" 1 6" 1 4" 1 4" I I I I I I Ti_7 ------------ - 7-7- F J L--J L_i�__4 I Irl I I I J a I L� r---- Ad 0 r _ �_ ? I �_____J L J L___ -----� r ----- I I LJ I a II I L------- —J L-----j BULKHEAD/SOFFIT FRAMING WOOD CLADDING DIGITAL MENU DISPLAY SCREENS, PER SCHEDULE DISPLAY SCREEN BRACKET, PER SCHEDULE. BRACKET AFFIXED TO WALL PER MANUFACTURES RECOMMENDATIONS AND REQUIREMENTS DIRRECTLY OVER THE TOP OF WOOD SLAT PANELS. BULKHEAD/SOFFIT FRAMING. PROVIDE IN -WALL BLOCKING FOR DISPLAY SCREEN BRACKETS PER MANUFACTURES RECOMMENDATIONS AND REQUIREMENTS. 3 DIGITAL MENU SECTION scale: 1 1/2" = 1 -0 � �Y�t _ �1�� J j rT- _ L� LJ ail IL ------ J L---- EQ. ----------------------------------`6' 6'•=-------- -- CENTER \ ASSEMB OF MENU DIGITAL MENU BOARDS - STANDARD MOUNT Scale: 3/4" = V-0" I I I LO I I I MAX. LENGTH POWER (5'-6") MAX. LENGTH DATA (5-6") METAL RECESSED CABLE MANAGEMENT AND POWER STORAGE BOX. MINIMUM (1) RECEPTACLES AND (1) DATA PORT PER SCREEN. MINIMUM (4) OUTLETS AND (4) DATA PORTS PER STORE. CENTER OF MENU BOARDS AT 7' - 4" (2235MM) A.F.F. MIN., 8' - 6" (2590MM) A.F.F. MAX. DIMENSION OF CENTER OF M MENU BOARDS AT 8'-8 1/2" AFF. 3/4" PLYWOOD BACKING BEHIND WALL FINISH, SECURED TO STRUCTURE WALL MOUNTED MENU BOARD BRACKET DIGITAL SCREEN STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !A GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 WRIGISDI CSTATE TIN LEE HILL OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O ma x , W Q Q O 00 Q VJ w 0 co Z LU O Z 0r 07 0 z0 < Z U U Ll.l O W W 2i O 0 d W 0 000 d M W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: INTERIOR DETAILS - WALL SCALE: AS SHOWN SHEET NUMBER: 1502 METAL WALL CAP AT FRP Scale: 6" = 1'-0" FRP PER ELEVATIONS C CHANNEL COUNTER SUNK SCREWS FRP PER ELEVATIONS CEMENTITOUS BACKER BOARD WALL TILE PER SCHEDULE METAL SCHLUTER JOLLY EMBEDDED IN GROUT CLEAR SILICONE ALUMINUM "J" MOULDING. COLOR TO MATCH WALLCOVERING P-LAM SURFACE SUPPLIED BY CASEWORK VENDOR, SECURE TO WALL PER MFR'S RECOMMENDATION SURFACE OF WALL TO BE PRIMED AND SEALED PRIOR TO APPLICATION OF WALL COVERING WALL TYPE PER FLOOR PLAN OTILE TO P-LAM OUTSIDE CORNER Scale: 6" = 1'-0" PANELS MOUNTED WITH ALUMINUM Z-CLIPS SPACED PER MFR RECOMMENDATION WD0077 PANELS PER CASEWORK VENDOR REFER TO ELEVATIONS FOR REVEAL HEIGHTS SUBSTRATE PER MFR RECOMMENDATION WALL TYPE PER FLOOR PLAN METAL WALL CAP Scale: 6" = V-0" BRICK PER ELEVATIONS 1" C CHANNEL COUNTER SUNK SCREWS TILE PER ELEVATIONS BRICK AND TILE TII C f]C� C(�LJ CfII II C 7 TILE AT DRIVE THRU WINDOW Scale: 3" = V-0" PER MFR 1DATION NTED WITH Z-CLIPS SPACED COMMENDATION =L (WD0077) PER SCHEDULE W T1 W E; THIN BRICK TO SOFFIT - PLAN VIEW Scale: 3" = 1'-0" WALL TYPE PER LEGEND CLEAR SEALANT METAL STARTER STRIP EMBEDDED IN GROUT HEIGHT PER PLAN CEMENTITOUS BACKER BOARD WALL TILE PER SCHEDULE 6 TILE TO PAINTED WALL TRANSITION Scale: 6" = 1'-0" BACKER ROD & SEA' ""IT THIN BRICK ELEVAT CEMENT B( MOI VVALL FE PER MFR NDATION WALL TILE PER SCHEDULE METAL SCHLUTER JOLLY EMBEDDED IN GROUT WALL TILE PER SCHEDULE CEMENTITOUS BACKER BOARD WALL TYPE PER FLOOR PLAN TILE TO TILE OUTSIDE CORNER Scale: 6" = 1'-0" BLACK -OUT WINDOW FILM APPLIED TO INTERIOR FACE OF GLASS PRIOR TO WALL; SEE EXTERIOR ELEVATION FOR FULL EXTENT EXTERIOR FACE OF GLASS EDGE OF EXISTING STOREFRONT BASE BEYOND *PLAN SECTION WALL AT STOREFRONT Scale: 3" = V-0" K PER SCHEDULE ICONE 1 "J" MOULDING. ) MATCH WALLCOVERING _LCOVERING PER E. APPLY TO WALL i RECOMMENDATION E ELEVATIONS AND SEALANT :EFRONT STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !jaGRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS D MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT C) 06 Q N 3: 00 v!!^^ J VJ w 0 C/) O Z 0r 07 0 z0 < Z U U Ll.l O w w !Y d W !Y d (3) W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: INTERIOR DETAILS - WALL SCALE: AS SHOWN WOOD PANEL REVEAL Scale: 6" = V-0" WOOD PANEL/THIN BRICK Scale: 6" = V-0" > INSIDE CORNER THIN BRICK/WALL COVERING Scale: 6" = V-0" > INSIDE CORNER THIN BRICK( Scale: 6" = V-0" STOREFRONT SHEET NUMBER: 1503 WOOD TRIM ( Scale: 3" = 1'-0" ACT CEILING WOOD PANEL_ 3 Scale: 6" = V-0" HANGAR WIRE AT EACH PERIMETER MAIN TEE AND PERIMETER CROSS TEE MAIN TEE OR CROSS TEE (SUSPENSION SYSTEM) HEAVY DUTY STABILIZER BAR TO MAINTAIN PERIMETER TEE SPACING 3/4" CLEAR AT ONE END IN EACH DIRECTION. DO NOT FASTEN THIS END TO THE CLOSURE ANGLE. AT OTHER END IN EACH DIRECTION, FASTEN TEES TO CLOSURE ANGLE. WOOD TRIM, MATCH WD0077 2 X 2 CLOSURE ANGLE, MINIMUM. ACT CEILING PANEL cmj`5 CEILING PER RCP 6 TILE CEILING Scae 6 1 0 STEEL FLAT BAR TRIM AT BOTTOM AND TOP OF PANELS, TYP. SUBSTRATE PER MFR RECOMMENDATION PANELS MOUNTED WITH ALUMINUM Z-CLIPS, SPACED PER MFR RECOMMENDATION WOOD VENEER PANELS PER CASEWORK VENDOR WALL TYPE PER FLOOR PLAN TOP AT CEILING CLEAR SEALANT METAL STARTER STRIP EMBEDDED IN GROUT CEMENTITOUS BACKER BOARD WALL TILE PER SCHEDULE WALL TYPE PER LEGEND 2,WOOD PANEL @ GYP SOFFIT Scale: 6 = 1 -0 I ILL r LAX LLL VP% I IVIVJ 4" LIGHT COVE ( Scale: 3" = 1'-0" WALL TYPE PER FLOOR PLAN WOOD PANEL (WD0077) PANEL MOUNTED WITH ALUMINUM Z-CLIPS SPACED PER MFR RECOMMENDATION SUBSTRATE PER MFR RECOMMENDATION STEEL FLAT BAR TRIM AT BOTTOM AND TOP OF PANELS, TYP. 7'-6"AFF 5/8" GYP PAINTED PER RCP TILE PAINTED GYP PER ELEVATIONS/RCP WALL TYPES PER FLOOR/FRAMING PLANS LED STRIP PER 1105 PAINTED GYP PER ELEVATIONS/RCP S'-0"AFC � PER RCP LED STRIP PEF GYP BD, PAINT PER RCP TILE BEYOND BACKBAR SOFFIT 5„ 4" LIGHT COVE ( Scale: 3" = V-0" WALL TYPES PER FLOOR/FRAMING PLANS LED STRIP PER RCP PAINTED GYP PER ELEVATIONS/RCP _ SEE 1104 FOR ELEVATION WOOD PANEL WALL TYPE PER FRAMING PLAN GYP BD, FINISHED PER INTERIOR ELEVATIONS LED STRIP PER RCP 12'-0"AFF WOOD PANEL WD0077 PER CASEWORK VENDOR ALL EXPOSED EDGES TO BE EDGE BANDED, TYP. 8'-0"AFF GYP BD, PAINT PER RCP STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD :0 GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS D C TIN LEE HILL OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT C) ,r W Q O W UQ U) Z Z � O v! 20 z0 a oz U U WO W 0 W O 0 a W 000 a rnw STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: INTERIOR DETAILS - WALLS & CEILING SCALE: AS SHOWN scale: 1 1 /2" = 1'-0" SHEET NUMBER: 1504 FASTEN TO STRUCTURE PER CISCA 3-4 (FIGURES 2, 3, 4, AND 5) AS MODIFIED BY ASCE 7-05. SECTION 13.5.6.2.2 HANGAR WIRE AT EACH PERIMETER MAIN TEE AND PERIMETER CROSS TEE 3/4" CLEAR AT ONE END IN EACH DIRECTION. DO NOT FASTEN THIS END TO THE CLOSURE ANGLE. AT OTHER END IN EACH DIRECTION, FASTEN TEES TO CLOSURE ANGLE. STABILIZER BAR TO MAINTAIN PERIMETER TEE SPACING MAIN TEE OR CROSS TEE (SUSPENSION SYSTEM)HEAVY DUTY 2 X 2 CLOSURE ANGLE, MINIMUM. SEE NOTE AT TOP PERIMETER SUPPORT NOT REQUIRED IN SEISMIC DESIGN CATAGORY C FOR CEILINGS LESS THAN 144 SF LIGHT FIXTURES WEIGHING LESS THAN 10 POUNDS SHALL BE CONNECTED TO STRUCTURE ABOVE BY (1) 12 GAGE TAUT OR SLACK WIRE LIGHT FIXTURES WEIGHING MORE THAN 10 POUNDS AND LESS THAN 56 POUNDS, AND AIR TERMINALS / SERVICES WEIGHING MORE THAN 20 POUNDS AND LESS THAN 56 POUNDS SHALL BE CONNECTED TO STRUCTURE ABOVE BY (2) 12 GAGE TAUT OR SLACK WIRES ATTACHED AT DIAGONAL CORNERS LIGHT FIXTURES, AIR TERMINALS, AND SERVICES SHALL BE POSITIVELY ATTACHED TO THE CEILING SYSTEM LIGHT FIXTURE AND MECHANICAL SERVICE FOUR 12 GAGE MINIMUM WIRES SPLAYED 90 DEGREES (IN PLAN) FROM EACH OTHER AND SECURED TO MAIN RUNNER WITHIN 2" OF INTERSECTION. EACH END OF EACH WIRE TO BE LOOPED AND WRAPPED AROUND ITSELF 3 TIMES MINIMUM WITHIN A 3" MAX LENGTH. o� FOR SPANS UP TO 6-0", USE A SINGLE 20 GAGE 1 5/8" COMPRESSION STRUT FASTENED TO MAIN TEE WITH (2) NO 8 SCREWS AND TO STRUCTURE WITH (2) HILTI X-DNI .145 DIA X 3/4". FOR SPANS UP TO 9'-0", USE DOUBLE COMPRESSION STRUT. LATERAL BRACING FOR CEILINGS EXCEEDING 144 SF CONTRACTOR OPTION FOR CATEGORY C: PROVIDE ALTERNATIVE LATERAL BRACING DESIGN BASED ON ASCE 7 SECTION 13.3.1 AND 13.5.6.1 Aso EXCEPT AS INDICATED IN DETAILS C AND F, COMPONENTS OF MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION SHALL BE INDEPENDENTLY SUPPORTED AND BRACED FROM STRUCTURE - 12 GAGE MINIMUM HANGAR WIRES AT 4'-0" OC EACH DIRECTION - NO MORE THAN 1:6 OUT -OF -PLUMB, TYPICAL WIRE LOOPED AND WRAPPED AROUND ITSELF 3 TIMES MINIMUM AT EACH END OF HANGAR WIRE WITHIN A 3" MAXIMUM LENGTH GENERALSUPPORT WHERE HANGAR WIRES ARE MORE THAN 1:6 OUT - OF -PLUMB, PROVIDE COUNTER -SLOPING WIRES MAINTAIN HANGAR WIRE SPACING AND CAPACITY BELOW OBSTRUCTION �000 METAL -FRAMED TRAPEZE AS NECESSARY TO AVOID OBSTRUCTIONS ACOUSTICAL CEILING PANELS COMPLY WITH ADDITIONAL PROVISIONS OF ASTM C635, ASTM C636, CISCA 3-4, AND ASCE 7-05, SECTION 13.5.6. LIGHT FIXTURES AND AIR TERMINALS / SERVICES WEIGHING MORE THAN 56 POUNDS AND ALL PENDANT LIGHT FIXTURES SHALL BE SUPPORTED DIRECTLY FROM STRUCTURE ABOVE USING APPROVED HANGARS SEISMIC DESIGN CATEGORY C: PROVIDE FLEXIBLE CONNECTION TO SPRINKLER HEAD THAT ALLOWS CEILING TO MOVE 3/8" IN ALL HORIZONTAL DIRECTIONS. SEISMIC DESIGN CATEGORY D, E, ANF F: PROVIDE FLEXIBLE CONNECTION TO SPRINKLER HEAD THAT ALLOWS CEILING TO MOVE 1" IN ALL HORIZONTAL DIRECTIONS. Q LO SPRINKLER HEAD CLEARANCE PROVIDE CEILING EXPANSIOP AS NECESSARY, DIVIDING CE AREAS NO GREATER THAN 2; LOCATE BRACING AT 12'-0" OC EACH DIRECTION AND WITHIN 6-0" OF PERIMETER WALLS, PARTITIONS, OR EXPANSION JOINTS EXPANSION JOINT FOR CEILINGS EXCEEDING 2500 SF NOT REQUIRED IN SEISMIC DESIGN CATEGORY C 2 SUSPENDED ACOUSTICAL CEILING SYSTEM -IBC DESIGN CATEGORY C, D, E, F scale: 1 1 /2" = 1'-0" FASTEN TO STRUCTURE PER CISCA 3-4 (FIGURES 2, 3, 4, AND 5) AS MODIFIED BY ASCE 7-05. SECTION 13.5.6.2.2 HANGAR WIRE AT EACH PERIMETER MAIN TEE AND PERIMETER CROSS TEE 3/4" CLEAR AT ONE END IN EACH DIRECTION. DO NOT FASTEN THIS END TO THE CLOSURE ANGLE. AT OTHER END IN EACH DIRECTION, FASTEN TEES TO CLOSURE ANGLE. GRID SUSPENSION SYSTEM 2 X 2 SHEET METAL ANGLE PER SUPPORT NOT REQUIRED IN SEISMIC DESIGN CATAGORY C FOR CEILINGS LESS THAN 144 SF LIGHT FIXTURES WEIGHING LESS THAN 10 POUNDS SHALL BE CONNECTED TO STRUCTURE ABOVE BY (1) 12 GAGE TAUT OR SLACK WIRE LIGHT FIXTURES WEIGHING MORE THAN 10 POUNDS AND LESS THAN 56 POUNDS, AND AIR TERMINALS / SERVICES WEIGHING MORE THAN 20 POUNDS AND LESS THAN 56 POUNDS SHALL BE CONNECTED TO STRUCTURE ABOVE BY (2) 12 GAGE TAUT OR SLACK WIRES ATTACHED AT DIAGONAL CORNERS. LIGHT FIXTURES, AIR TERMINALS, AND SERVICES SHALL BE POSITIVELY ATTACHED TO THE CEILING SYSTEM C LIGHT FIXTURE AND MECHANICAL SERVICE SUPPORT LV V(ll L UI \/"1V IIVV /"�I IL-V VV L(lVl I DIRECTION AND WITHIN 6-0" OF PERIMETER WALLS, PARTITIONS, OR EXPANSION JOINTS EXCEPT AS INDICATED IN DETAILS C AND F, COMPONENTS OF MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION SHALL BE INDEPENDENTLY SUPPORTED AND BRACED FROM STRUCTURE 12 GAGE MINIMUM HANGAR WIRES AT 4'-0" OC EACH DIRECTION - NO MORE THAN 1:6 OUT -OF -PLUMB. TYPICAL WIRE LOOPED AND WRAPPED AROUND ITSELF 3 TIMES MINIMUM AT EACH END OF HANGAR WIRE WITHIN A 3" MAXIMUM LENGTH GENERAL SUPPORT WHERE HANGAR WIRES ARE MORE THAN 1:6 OUT - OF -PLUMB, PROVIDE COUNTER -SLOPING WIRES MAINTAIN HANGAR WIRE SPACING AND CAPACITY BELOW OBSTRUCTION 5/8" GYPSUM BOARD ••0 METAL -FRAMED TRAPEZE AS NECESSARY TO AVOID OBSTRUCTIONS GYPSUM BOARD CONSTRUCTION SHALL COMPLY WITH ADDITIONAL PROVISIONS OF SBC SECTION 2508. METAL SUSPENSION SYSTEM SHALL CONFORM WITH ASCE 7, SECTION 13.5.6.2.1, ASTM C635, ASTM C636, ASTM C754, AND CISCA 3-4. SEISMIC DESIGN CATEGORY C: PROVIDE FL CONNECTION TO SPRINKLER HEAD THAT AI MOVE 3/8" IN ALL HORIZONTAL DIRECTIONS SEISMIC DESIGN CATEGORY D, E, ANF F: PF CONNECTION TO SPRINKLER HEAD THAT AI MOVE 1" IN ALL HORIZONTAL DIRECTIONS. LIGHT FIXTURES AND AIR TERMINALS / SERVICES WEIGHING MORE THAN 56 POUN AND ALL PENDANT LIGHT FIXTURES SHALL SUPPORTED DIRECTLY FROM STRUCTURE ABOVE USING APPROVED HANGARS SPRINKLER HEAD CLEARANCE D 4GE MINIMUM WIRES SPLAYED 90 DEGREES ROM EACH OTHER AND SECURED TO MAIN ITHIN 2" OF INTERSECTION. EACH END OF TO BE LOOPED AND WRAPPED AROUND VIES MINIMUM WITHIN A 3" MAX LENGTH. PROVIDE CEILING EXPANSION JOINTS AS NECESSARY, DIVIDING CEILING INTO AREAS NO GREATER THAN 2500 SF 2" 8" MAX EACH SIffE 7 S UP TO 6-0", USE A SINGLE 20 GAGE 1 5/8" 'ION STRUT FASTENED TO MAIN TEE WITH (2) NO 8 „ND TO STRUCTURE WITH (2) HILTI X-DNI .145 DIA X 3/4" FOR SPANS UP TO 9'4'. USE DOUBLE COMPRESSION STRUT LATERAL BRACING REQUIRED IF ANY OF THE FOLLOWING EXISTS: -GYPSUM BOARD CEILING THAT EXTENDS WALL-TO-WALL EXCEEDS 1000 SF -GYPSUM BOARD CEILING THAT DOES NOT EXTEND WALL-TO-WALL EXCEEDS 144 SF CONTRACTOR OPTION FOR CATEGORY C: PROVIDE ALTERNATIVE LATERAL BRACING DESIGN BASED ON ASCE 7 SECTION 13.3.1 AND 13.5.6.1 EXPANSION JOINT FOR CEILINGS EXCEEDING 2500 SF NOT REQUIRED IN SEISMIC DESIGN CATEGORY C SUSPENDED GYP BD CEILING - IBC SEISMIC CATEGORY C, D, E, F scale: 1 1/2" STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !jaGRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 WREGISD 7STATE TIN LEE HILL OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O Ir- 06 04 Q Q O 3 00 O C/) Q �^^ VJ Z w 0 co O Z Ir 07 0 z0 < Z U C) Ll.l O W G LU O !Y d W 0 00 d W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: INTERIOR DETAILS - SUSPENDED CEILING SCALE: AS SHOWN SHEET NUMBER: 1505 HARDWOOD SLATS SECURED TO SUBSTRATE/ STRUCTURE PER MANUFACTURER'S RECOMMENDATIONS 'I 1/8" 2 1/4" CUSTOMER FACING SIDE M 1/2" PLYWOOD BACKER (TYP.) INTERIOR SIDE `' INTERIOR SIDE TO BE SECURED TO SUBSTRATE / STRUCTURE PER DETAILS A ENLARGED SECTION PROFILE NOT TO SCALE I? EN ELEVATION 3' - 11 1/2" BACKER 20 STAVES, NO BUTT JOINTS RDWOOD SLATS ZECTION OF GRAIN. P. ALL SLATS. :TAL CORNER TRIM R DETAILS :TAL BOTTOM TRIM PER DETAILS 34" MAX. AFF_ OPTIONAL L LIGHTING BY ALUM. Z-CL FINIS ^'JNTERTOP JNTERTOP 3STRATE FAL ANGLE, NALL )NENTS ) BY JD BY G.C. )TED E. FINISH PANEL - BUILT-UP COUNTERTOP OVERHANG Scale: 6" = V-0" 1 1/2" CAFE BAR NOTE: ALL COMPONENTS FURNISHED BY BAR DIEWALL OTHERS AND LIGHT NOTE: BAR FINISH INSTALLED BY G.C. ALL COMPONENTS PANEL STAINLESS STAPLE UNLESS NOTED OR POWDER COATED OTHERWISE. FURNISHED BY OTHERS AND INSTALLED BY G.C. UNLESS NOTED OTHERWISE. STEEL FASTENER ., STRIP LIGHT AT BANQUETTE scale: 1 1/2" = V-0" NOTES: 1. LOCATE PUMP WITHIN CORD LENGTH LIMIT. ORIENT WITH PUMP HEAD LEFT, RIGHT AND AT BOTTOM. LOOSEN PUMP HEAD CLAMP, ROTATE AND RE -TIGHTEN AS REQUIRED PER ORIENTATION TO PROVIDE FRONT ACCESS TO FLOW. ADJUSTMENT WITHIN CORD LENGTH LIMIT. 2. USE LOCKTITE ON ISOLATOR THREADS. DO NOT OVER TIGHTEN. 3. LOOSEN PUMP HEAD CLAMP, ROTATE AND RE -TIGHTEN AS REQUIRED FOR PUMP ORIENTATION. 4. BACKER BOARD'S ASSEMBLY COMPONENTS INCLUDE: (1) BACKER BOARDS (4) TENETS, 1/4-20 VENDOR MOUNTED (8) WOOD SCREWS #8 1-1/4" (32MM) (4) NEOPRENE ISOLATORS, KARMAN RUBBER, K84-60 NEOPRENE (4) LOCK NUTS, 1/4-20 NYLON (4) WASHERS, 1/4" (7MM) FLAT INTERIOR FACE OF DIEWALL SEE NOTES ABOVE FOR ASSEMBLY ITEMS PUMP ATTACHED TO BACKER BOARD WITH ASSEMBLY COMPONENTS I 10"X10" (250MM X 250MM) BACKER BOARDS. �{ ATTACH TO PLYWOOD SUBSTRATE WITH SILICONE ADHESIVE AND WOOD SCREWS. SILICONE PERIMETER. FINISHED FLOOR L SHROUD/SPLF MATCH COUN' LED STRIP LIG 34" MAX. A.F.F. u ESP SHROUD - CORIAN scale: 6" = V-0" 1 1/2" X 1 1/2" (38MM X 38MM) CORROSION RESISTANT �►�^ STEEL ANGLE MECHANICALLY FASTEN COUNTER -SUNK CORROSION RESISTANT FASTENERS AT 6"(150MM) O.C. WITH 3/4" (19MM) EMBEDMENT. UNDERCOUNTER REFRIGERATOR SECTION VIEW NOTES DO NOT BLOCK GROMMET OPENING. CUT ANGLE AS REQUIRED TO MAINTAIN MIN. 1/2" (13MM) CLEAR AROUND OPENING. MECHANICALLY FASTEN ANGLE TO COUNTERTOP SUBSTRATE OR EPDXY FASTEN ITO COUNTERTOP. 1/2" (13MM) PREFERRED OFFSET DISTANCE FROM EDGEOFCOUNTERTOR- 1. 24" (610MM) 1 1/2" X 1 1/2" (38MM X 38MM) STEEL ANGLE TO BE USED WITH SINGLE DOOR REFRIGERATORS. 2. 48" (1220MM) 1 1/2" X 1 1/2" (38MM X 38MM) STEEL ANGLE TO BE USED WITH DOUBLE DOOR REFRIGERATORS. ECO-GRIP SEALANT 6" (150MM) METAL BASE PER SCHEDULE. ADHERE TO WALL PER MFR'S RECOMMENDATION. ALUMINUM DOWEL SECURED INTO SUB FLOOR & DIEWALL CLEAR SILICONE SEALANT FLOORING PER SCHEDULE N ECO-GRIP BASE CAP. COLOR TO MATCH ECO-GRIP FLOORING INSTALL CASEWORK DIEWALL PRIOR TO ECO-GRIP FLOORING ECO-GRIP EPDXY ADHESIVE CONCRETE SLAB ECO-GRIP FLOORING — 1/4" (6MM) ROUTED \ COVE I I PLASTIC SHIM REQUIRED - 1/4" MIN. I I I I L- _J FINISH PANEL - 6" BASE scale: 6" = V-0" I I I COUNTERTOP I ABOVE111110I I - I STEEL ANGLE CENTERED ON REFRIGERATOR UNDERCOUNTER REFRIGERATOR COUNTERTOP DEPTH MAY VARY 2' - 5" (737MM) / FRONT EDGE OF COUNTERTOP TO FACE OF ANGLE 0 0 Z 2 5 2 0 LO v I LU O [--w- FRONT EDGE OF I COUNTERTOP ABOVE III o I J m III II II O LU m I I III III Lu I A I STARBVCKSU 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 WREGISD 7STATE TIN LEE HILL OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 06 04 Q Q O 00 Q ��^^ V J � LLI 0 LU O 2i Z � 07 0 z 0 < Z U U Ll.l O W � W O � 0 0-W 00 d (:;) W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: INTERIOR DETAILS - CASEWORK SCALE: AS SHOWN - FINISH APPLICATION (MAD 101-V) SLAT W/ REVEAL 3 scale: 3/4" = 1'-0" 2 ESPRESSO PUMP MOUNTED AT DIE WALL scale: 1 1/2" = V-0" 1 UN���OUNTER REFRIGERATOR STOP INSTALLATION scale: �D�E SHEET NUMBER: 1506 CASEWORK SCHEDULE - "C" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS CABINET 17573 1 CABINET - BACKBAR COUNTER SUPPORT PANEL - 31N 75MM SB GC 17574 2 CABINET - BACKBAR SINK OR ICE - 151N 380MM SB GC 17740 2 CABINET - BACKBAR - 301N 760MM SB GC 17741 5 CABINET - BACKBAR 151N 380MM SB GC 17743 1 CABINET - DT POS - 301N 760MM SB GC 17744 1 CABINET - FRONTBAR POS BRIDGE - 221N 560MM SB GC 17745 1 CABINET - BACKBAR DRAWER - 151N 380MM SB GC 17747 4 CABINET - BACKBAR TRASH - 151N 380MM SB GC 17896 1 CABINET - BACKBAR CUBBY - 151N 380MM SB GC 19281 2 CABINET - ESPRESSO ICE BIN STAINLESS - 201N 510MM SB GC 21190 1 CABINET - FRONTBAR TRASH - 151N 380MM SB GC 21191 1 CABINET - FRONTBAR DRAWER - 151N 380MM SB GC 21192 2 CABINET - FRONTBAR POS - 301N 760MM SB GC 21193 2 CABINET - ESPRESSO CUBBY WITH OPEN BACK - 181N 455MM SB GC 22573 1 CABINET - FRONTBAR - 301N 760MM SB GC 22975 1 CABINET - FRONTBAR DEL- 151N 380MM SB GC 23385 1 CABINET - BOTTOM SHELF - 91N 230MM SB GC 23388 1 CABINET - BACKBAR - 181N 460MM SB GC 23391 1 CABINET - CBE ICE DISPENSE BRACKET SB GC 23392 1 CABINET - CBE ICE DISPENSE DOOR - 241N 610MM SB GC 23393 3 CABINET - CBE MILK DISPENSE BRACKET SLIDE SB GC 23394 2 CABINET - CBE MILK DISPENSE DOOR - 101N 255MM SB GC 23395 1 CABINET - CBE MILK DISPENSE DOOR - 11 IN 280MM SB GC 23426 1 CABINET - WRM LOW - 301N 760MM SB GC CAFE 20352 1 FREESTANDING INLINE 2 UNIT SHORT - 721N 1830MM - WALNUT WD0077 SB GC 23963 1 WASTE AND RECYCLE STATION THREE DROP - WARM BROWN WOODGRAIN AND WHITE PL0030 CP0002 SB GC X0001 1 CAFE - TABLE TOP - VARIABLE LENGTH SB GC WD007 COUNTERTOP 17809 2 COUNTERTOP - HAND SINK WITH LOW SPLASH STAINLESS - 151N 380MM SB GC 17828 7 COUNTERTOP - BACKSPLASH - VARIABLE LENGTH SB GC 17830 1 COUNTERTOP - POS - 821N 2085MM SB GC 18720 1 COUNTERTOP - BREW WITH TRASH DROP - LF - 901N 2285MM SB GC 19713 1 COUNTERTOP - WARMING - RF - 901N 2285MM SB GC 20062 1 COUNTERTOP - ESPRESSO METRO - LF - 1391N 3530MM SB GC 20063 1 COUNTERTOP - FRONTBAR CAP - 1391N 3530MM SB GC 23409 1 COUNTERTOP - CBE IN -LINE LF - 1381N 3505MM SB GC 23433 1 COUNTERTOP - WRM RF - 791N 1930MM SB GC DIEWALL 17822 1 DIEWALL - 151N 380MM SB GC 17831 1 DIEWALL - POS - 821N 2085MM SB GC 18853 1 DIEWALL - 301N 760MM SB GC 20064 1 DIEWALL - ESPRESSO - 1391N 3530MM SB GC 23412 1 DIEWALL - FRAMING UPPER - VARIABLE LENGTH SB GC 23413 4 DIEWALL - SUPPORT ARM UPPER SB GC FIT KIT 17894 2 FIT KIT - CABINET FILLER PANEL ISB GC 18083 1 FIT KIT - SIDE SPLASH - RF ISB GC OTHER 11155 2 ESPRESSO MACHINE PUMP MOUNT - 10X101N 255X255MM SB GC 18145 1 COUNTERTOP SUPPORT LEG SB GC 20066 1 SHROUD - 1391N 3530MM SB GC 20633 1 COUNTERTOP SUPPORT LEG SLIM SB GC PANEL 17832 1 PANEL - 821N 2085MM SB GC 20065 1 PANEL - 1391N 3530MM SB GC 23415 1 PANEL - CBE FRONT PANEL UPPER IN -LINE SB GC 23416 2 PANEL - CBE INTERIOR PANEL UPPER SB GC 23417 1 2 CABINET - CBE UPPER SIDE PANEL SB GC CASEWORK FINISH SCHEDULE ENGINE ZONE MATERIAL DESCRIPTION FINISH CODE COMMENTS COMPOSITE - BRUSHED DARK GREY COUNTERTOPS-BACKBAR COMPOSITE - BRUSHED DARK GREY CP0057 COUNTERTOPS -ESPRESSO COMPOSITE - BRUSHED DARK GREY CP0057 COUNTERTOPS-FRONTBAR COMPOSITE - BRUSHED DARK GREY CP0057 COUNTERTOPS -SHROUD COMPOSITE - BRUSHED DARK GREY CP0057 KEYSTONE GRAY CABINETS - UPPER KEYSTONE GRAY X7504 METAL - ALUMINUM - BRUSHED CABINETS - UNDERCOUNTER I METAL -ALUMINUM -BRUSHED METAL - FLAT BLACK POWDERCOAT CABINETS - DOOR PULL METAL - FLAT BLACK POWDERCOAT MT0028 CABINETS - UNDERCOUNTER METAL - FLAT BLACK POWDERCOAT MT0028 FRAMING AND HARDWARE METAL - FLAT BLACK POWDERCOAT MT0028 METAL - STAINLESS STEEL - BRUSHED CABINETS - CABINET LEG METAL - STAINLESS STEEL - BRUSHED #4 BRUSHED 16GA CABINETS - UNDERCOUNTER ICE BIN METAL - STAINLESS STEEL - BRUSHED #4 BRUSHED 16GA COUNTERTOPS - HAND SINK METAL - STAINLESS STEEL - BRUSHED #4 BRUSHED 16GA PLAM -GRAPHITE CABINETS - EXTERIOR PLAM -GRAPHITE PL0003 CABINETS - UPPER PLAM - GRAPHITE IPL0003 PLAM - MOTTLED BLACK CABINETS - UNDERCOUNTER PLAM - MOTTLED BLACK IPLOO19 CABINETS - UPPER PLAM - MOTTLED BLACK IPLOO19 WOOD - WALNUT - REVEAL SLAT - VERTICAL FINISH PANELS- FRONTBAR WOOD -WALNUT -REVEAL SLAT -VERTICAL WD0077 MAD101-V SPECIALTY EQUIPMENT SCHEDULE - "E" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS COOLING 20010 1 FRIDGE NITRO 2 TAP JT NITCOM LH SB GC KIT INCLUDES UNDERCOUNTER FRIDGE, FONT, TRAY, AND TUBING EQUIPMENT 17564 1 BLENDER PITCHER RINSER WITH SENSOR SB GC VITAMIX: SPRAYPARK 21679 1 NITROGEN GENERATOR ELEMENT COMPACT SB GC ELEMENT7: NG3000 SERIES 22885 1 BREWER CLOVER VERTICA DOUBLE SB GC DONLIM: CM9700 23381 1 BREWER CLOVER VERTICA CORD SB GC PENTAIR: SHURFLO EV9910-00 23419 3 MILK DISPENSER SB GC DONLIM: MILK MACHINE IP220238 23442 1 OVEN COMBI SB GC CONVOTHERM OES 10.10 MINI eT FOOD CASE 23444 1 FOOD CASE - WARMING WALL - 1000 SQUARE SB GC FLEXZONE 4 TIER FXZNA10S4S-SF61 ICE 19278 2 ICE - BIN DROP IN 45LB 20KG HORIZONTAL SB GC ELKAY I LID-74763A\FSP211635 23183 1 ICE - MACHINE HMC1410ABT AIR COOLED SB GC Follett I Remote 1810, 2110 series Chewblet 23421 1 ICE - NUGGET ICE DISPENSER SB GC FOLLETT ID50 23422 1 ICE - NUGGET ICE DISPENSER RIDE SB GC FOLLETT IMDV-2CM SERIES 23423 1 ICE - NUGGET ICE DIVERTER SB GC FOLLETT IMDV- 2 SERIES 23424 1 ICE - NUGGET ICE DIVERTER CONTROL PANEL SB GC 23526 1 ICE - BIN ADAPTOR FOLLETT 13110H22H30DV PEDESTAL FOR B110 SB GC OTHER 10179 2 HAND DRYER SURFACE MOUNTED SB GC 10977 2 PAPER TOWEL DISPENSER FULL SIZE - TRANSLUCENT GRAY SB GC 11115 2 SOAP DISPENSER SINK MOUNTED SB GC 21551 3 POWER EXTENSION DUAL RECEPTACLE AND USB - BLACK SB GC 21988 2 HAND DRYER BACK PANEL SB GC 22627 1 NITRO 2 TAP HANDLE WITH BADGE AND MOUNT KIT SB GC JOE TAP, FOR USE AT BACKBAR NITRO FONT 23420 2 REFRESHER DISPENSE SMALL SB GC STORAGE 10416 1 WORKROOM SHELVING - 361N 915MM SB GC 10462 1 WORKROOM SHELVING POSTS SB GC 22212 1 WORKROOM SHELVING CART KIT SB GC 23445 3 PASTRY COOLING RACK WALL MOUNTED SB GC TKO048 2 5 COMP LOCKER - 151N 380MM SB GC RELOCATED (EXISTING) SPECIALTY EQUIPMENT SCHEDULE - "RE" DESIGN ID COUNT DESCRIPTION COMMENTS COOLING 10110 1 FRIDGE REACH IN 1 DOOR RH - 291N 735MM TRUE: TG1R-1S-HC-LH STAR 10267 5 FRIDGE UNDERCOUNTER 1 DOOR - 271N 685MM DELFIELD: 406-STAR2 11083 1 FRIDGE REACH IN 2 DOOR - 51X351N 1295X890MM TRAULSEN: G20010 12618 2 FRIDGE UNDERCOUNTER 1 DOOR WITH SHELF - 271N 685MM DELFIELD: 406-STAR4 13676 1 FREEZER REACH IN 1 DOOR RH - 271N 685MM TRUE: T23F-HC-RH STAR 13682 1 FREEZER REACH IN 2 DOOR - 541N 1370MM TRUE: T-49F-HC STAR EQUIPMENT 10808 1 GRINDER DITTING KR1203 DITTING: KR 1203 12508 2 BLENDER QUIET MODEL ON COUNTER VITAMIX: THE QUIET ONE 15186 1 DISHWASHER HOT LOW STEAM HOBART: LXER ADVANSYS - HIGH TEMPERATURE 19742 2 ESPRESSO MACHINE MASTRENA II THERMOPLAN: MASTRENA II M2-CS 20032 2 OVEN EIKON E2S - BLACK MERRYCHEF / EIKON E2S STARBUCKS FOOD CASE 16238 1 FOOD CASE - ZEPHYR - 661N 1675MM STRUCTURAL CONCEPTS: ZEPHYR - SBZ6652DR ICE 18029 1 �ICE- BIN B110 BPF-1 ADAPTER KIT (011076103) REQUIRED WHEN PAIRING WITH 30" (760MM) ICE MACHINES OTHER 10091 1 CUP DISPENSER TALL HOT VERTICAL 10099 2 RESTROOM TOILET PAPER HOLDER 10172 2 RESTROOM SEAT COVER DISPENSER 10396 1 CUP DISPENSER SHORT HOT VERTICAL 10769 2 RESTROOM GRAB BAR VERTICAL - 181N 455MM 10791 2 CUP DISPENSER GRANDE VENTI COLD VERTICAL 10855 2 CUP DISPENSER GRANDE VENTI HOT VERTICAL 10858 1 CUP DISPENSER TALL COLD VERTICAL 10859 2 RESTROOM GRAB BAR - 481N 1220MM 10862 2 RESTROOM GRAB BAR - 361N 915MM 10947 1 SOAP DISPENSER WALL MOUNTED 10977 1 PAPER TOWEL DISPENSER FULL SIZE - TRANSLUCENT GRAY 11115 2 SOAP DISPENSER SINK MOUNTED 13330 1 MOBILE CUP DISPENSER CADDY 13584 1 CUP DISPENSER TRENTA COLD VERTICAL STORAGE 10222 1 WIRE SHELF GRID AT SINK 10416 8 WORKROOM SHELVING - 361N 915MM 10462 8 WORKROOM SHELVING POSTS 13578 2 DISHWARE DRYING RACK - 21 IN 535MM 17255 1 1 PASTRY TRAY CART - 601N 1525MM 17264 1 1 ROLLING PASTRY TRAY THAW RACK - 20X261N 51 OX660MM GRAPHICS AND ARTWORK SCHEDULE - "G" DESIGN ID I COUNT DESCRIPTION FURN. BY INST. BY COMMENTS GRAPHICS - ARTWORK 22674 1 ART - ANGELA MCKAY - FLORA OF HACIENDA SB GC SBXART_22674-FRAMED & MATTED - ART ALSACIA SIZE T-0" W X 5-3" H - NO MAT BORDER - OVERALL SIZE 6-0" W X 4'-6" H -CANVAS 1 - MAT 1 - FRAME 1" MT0038 BRUSHED BRASS. THIS IMAGE CANNOT BE CROPPED GRAPHICS - OTHER 11135 2 RESTROOM SIGN UNISEX ACCESSIBLE SB GC X12693 1 COMMUNITY BOARD MAGNETIC WALNUT WD0077 SB GC - 46X361N 1170X915MM RELOCATED (EXISTING) FURNITURE SCHEDULE - "RF" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS CHAIR 14308 1 CHAIR - CAFE SQUARE BACK WITH NARROW FRAME - DARK WARM BROWN DISTRESSED W D0001 SB GC TABLE 15099 1 TABLE - BASE CAFE HEIGHT DOME ACCENT - 181N 455MM BASE - HOT ROLLED STEEL MT0011 SB GC 21841 1 TABLE - TOP ROUND EDGE ROUND - 241N 610MM - WALNUT WD0077 SB GC DATA DEVICE SCHEDULE - "A" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS AUDIO VISUAL 10005 1 MUSIC SYSTEM SB SB 10015 3 SPEAKER RECESSED - WHITE SB SB 19339 1 AMPLIFIER - 40W SB SB 22725 1 DT DIGITAL PRODUCTION MONITOR SB SB PART OF RETAIL IT EQUIPMENT PACKAGE 22726 1 DT POS MONITOR ARM TRIPLE SURFACE MOUNTED SB SB PART OF RETAIL IT EQUIPMENT PACKAGE DATA 18744 1 EQUIPMENT RACK WITH LOCK - 241N 610MM JSB ISB GRAPHICS - INTERIOR MENU 22970 3 MENU BOARD - DIGITAL DISPLAY - 44X25.251N 1121X644MM - BLACK SB GC 22972 1 MENU BOARD - DIGITAL MENU BOARD MOUNTING BRACKET THREE SCREEN - BLACK SB GC POINT OF SALE 10075 1 CUP LABELER SB IGC RELOCATED (EXISTING) DATA DEVICE SCHEDULE - "RA" DESIGN ID I COUNT DESCRIPTION COMMENTS AUDIO VISUAL 10012 1 DT COMMUNICATION SYSTEM 12336 1 DT TIMER SYSTEM DATA 10002 1 COMPUTER MANAGER WORKSTATION 10007 1 PRINTER MANAGER WORKSTATION POINT OF SALE 10008 2 POS - REGISTER WITH COMPACT CASH DRAWER 10014 3 POS PRINTER 10022 1 MONEY COUNTER 10029 6 POS BANK 10075 3 CUP LABELER 14677 1 POS - DT TENDERING REGISTER PART OF RETAIL IT EQUIPMENT PACKAGE 14678 1 POS - DT EXPEDITOR PART OF RETAIL IT EQUIPMENT PACKAGE SECURITY 10024 1 SAFE LH - 20X18X261N 510X455X660MM 10028 1 SAFE BASE FURNITURE SCHEDULE - 7" DESIGN ID COUNT DESCRIPTION I FURN. BY INST. BY COMMENTS X5500 1 CUSTOM BENCH ISB GC BANQUETTE 23010 1 BANQUETTE - WALLFLOWER - VARIABLE LENGTH - WALNUT WD0077 SB GC 23012 1 BANQUETTE - WALLFLOWER CUSHION SEAT AND BACK - VARIABLE LENGTH - BLACK NATURAL F0046 SB GC CHAIR 17853 5 CHAIR - CAFE PYRAMID - BLACK AND GREY ROPE MT0028 F0195 SB GC 22878 4 CHAIR - LOUNGE COMF - BLACK AND CARAMEL BROWN NATURAL MT0028 F0008 SB GC 22931 7 CHAIR - STOOL COUNTER HEIGHT DOLLY - WALNUT WD0077 SB GC 23138 7 CHAIR - CAFE ASHER UPHOLSTERED BACK - WALNUT AND BLACK NATURAL WD0077 F0046 SB GC TKO077 1 CHAIR - MANAGERS WORKSTATION ISB JGC I STEELCASE SERIES ONE ARMLESS DESK TKO053 1 DESK - MANAGERS WORKSTATION SHELVES - 481N 1220MM SB GC TKO076 1 DESK - MANAGERS WORKSTATION - 48X24X271N 1220X61 OX685MM SB GC MIRROR 14350 2 MIRROR - RESTROOM ANGLED- 18X361N 455X915 M M SB GC OUTDOOR X1010 1 WEST ELM PORTSIDE OUTDOOR DINING TABLE SB GC 76.5" WEATHERED GREY SKU: 6810208 X1011 2 WEST ELM PORTSIDE OUTDOOR DINING BENCH SB GC 66" WEATHERED GREY SKU: 5605942 STORAGE TKO078 1 FILE MOBILE PEDESTAL WITH CUSHION AND LOCK SB GC TKO079 1 MANAGERS DESK CART - 24X201N 61 OX510MM SB GC TABLE 16520 4 TABLE - BASE CAFE HEIGHT DOME ACCENT - 201N 510MM - HOT ROLLED STEEL MT0011 SB GC 17246 2 TABLE - BASE FIXED T BASE END - 321N 815MM - HOT ROLLED STEEL MT0011 SB GC 17247 4 TABLE - BASE FIXED T BASE CENTER - 321N 815MM - HOT ROLLED STEEL MT0011 SB GC 17339 5 TABLE - CAFE METAL PEDESTAL BASE ROUND - 241N 610MM - BLACK MT0028 SB GC 17341 1 TABLE - ACCESSIBLE METAL WITH TAPERED LEGS - 36X241N 915X610MM - BLACK MT0028 SB GC 18468 2 TABLE - BASE CAFE T LEG - HOT ROLLED STEEL MT0011 SB GC 21799 1 TABLE - TOP ACCESSIBLE ROUND EDGE OBLONG - 48X241N 1220X610MM - WALNUT WD0077 SB GC 21841 2 TABLE - TOP ROUND EDGE ROUND - 241N 610MM - WALNUT WD0077 SB GC 21844 2 TABLE - TOP ROUND EDGE ROUND - 301N 760MM - WALNUT WD0077 SB GC X5000 2 WEST ELM ORGANIC MODULAR TABLE SB GC SIZE/COLOR: SMALL/DARK WALNUT SKU: 8066175 STARBUCKS° 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS D MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT C) Irx W Q Q C) co Q VJ W 0 W LU O Z 0Y 07 0 z0 < Z U U Ll.l O W LU 0 0- W 0 000 d (3) W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: CASEWORK AND FF&E SCHEDULES SCALE: AS SHOWN SHEET NUMBER: 1601 PAINT SCHEDULE DESIGN ID DESCRIPTION LRV FURN. BY INST. BY COMMENTS X7020 SW7020 BLACK FOX, OR EQUIVALENT 8 GC GC SW USE PRIMER CP-1; NCS - S 7502-Y; AKZO NOBEL - 30YY 10/038 X7504 SW7504 KEYSTONE GRAY GC GC FLOOR TREATMENT SCHEDULE - "T" DESIGN ID I AREA DESCRIPTION FURN. BY INST. BY COMMENTS PLASTIC 19795 �774 SF POLYVINYL FLOOR TILE - ECO-GRIP - PEWTER GC GC GC TO PROCURE FROM ALLIED INDUSTRIES TILE 20262 �952 SF TILE - FRENCH CLAY - CAFE - 24X241N 60OX600MM SB GC GROUT: MAPEI - 11 SAHARA BEIGE, OR EQUAL WALK OFF MAT 12243 �32 SF WALK OFF MAT - RECYCLED TIRE TILE - CHARCOAL - 12X121N 305X305MM SB GC CEILING TREATMENT SCHEDULE - "U" DESIGN ID I AREA DESCRIPTION FURN. BY INST. BY COMMENTS X19734 185 SF ACT - ULTIMA - 2X4FT 61X61CM GC GC WHITE; FOR ORDERING CONTACT DEB PICKENS AT DLPICKENS@ARMSTRONGCEILINGS.COM PH: 480-695-9053 PLASTIC 11302 �526SF �ACT- CALLA HEALTH ZONE - 2X2FT 61X61CM �GC GC FACTORY FINISH TO MATCH SW KEYSTONE GREY WALL BASE SCHEDULE - "B" DESIGN ID LENGTH DESCRIPTION FURN. BY INST. BY COMMENTS METAL BASE MT0011 34' - 10 1/2" IMETALBASE GC GC LOCALLY SOURCED TILE BASE 20269 121' - 6" TILE BASE - FRENCH CLAY - BRONZAGE - 6X121N 150X300MM SB GC GROUT: MAPEI - 02 PEWTER, OR EQUAL VINYL BASE 19795 305- 5 3/4" 1 POLYVINYL VINYL BASE - ECOGRIP - PEWTER GC GC WALL TREATMENT (AREA) SCHEDULE - "Q" DESIGN ID I AREA DESCRIPTION FURN. BY I INST. BY COMMENTS Brick 11477 �373SF MUTUAL MATERIALS SLIM BRICK GC GC REDONDO GRAY MISSION 30%, PEWTER MISSION 70%, RANDOM TILE 20230 �903 SF TILE - I COCCI - GRAPHITE - 24X241N 60OX600MM SB GC GROUT: MAPEI - 47 CHARCOAL, OR EQUAL WALL COVERING 11469 1723 SF FRP - WHITE GC GC X0002 604 SF MOMENTUM - PIMA - DEEP WATER SB GC LLN-PI-16, REVERSE HANG, RANDOM MATCH WINDOW FILM SCHEDULE - "Z" DESIGN ID AREA DESCRIPTION I FURN. BY INST. BY COMMENTS 19458 68 SF SXS-M6000 SILVER MIRROR OPAQUE JGC GC SOLY-X GLASS FINISHES STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 WREGISDI 7STATE TIN LEE HILL OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 06 Q O Co w 0 LU O G Gz 7 0Y n Q v/ 0 < Z U U W O LU ° LU O ° 0 aW oo a- rnW STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: INTERIOR FINISHES SCHEDULES SCALE: AS SHOWN SHEET NUMBER: 1602 LIGHTING FIXTURE SCHEDULE - "L" DESIGN ID COUNT DESCRIPTION FURN. BY I INST. BY I BULB COMMENTS 17796 40 LED STRING LIGHT BULBS SB IGC I I LENGTH: 59'-2" PENDANT 20802 8 PENDANT - SCHOOLHOUSE ELECTRIC ISAAC - NATURALBRASS SB GC 6 W LED, AS PACKAGED STEM: T-5" X22000 1 PENDANT - KUZCO HURON MP95103 - NATURAL BRASS SB GC INTEGRATED LED STEM 1: V-5", STEM 2: 2'-0", STEM 3: 2'-10" RECESSED CAN 21772 58 CAN - LED ADJUSTABLE RECESSED - 31N 75MM - WHITE - 80OLM FLOOD SB GC INTEGRATED LED SCONCE 20749 2 SCONCE - KUZCO PLUTO SINGLE -VINTAGE BRASS SB GC INTEGRATED LED 20750 2 SCONCE - KUZCO PLUTO TRIPLE - VINTAGE BRASS SB GC INTEGRATED LED STRIP 22217 8 STRIP - LED TAPE IN HOUSING - VARIABLE LENGTH - WHITE - 350LM PER FT SB GC INTEGRATED LED FIELD TRIMMABLE TO 0.91N LENGTHS TRACK 19411 2 TRACK - WITH CONNECTORS - 8FT 244CM - BLACK - 2 CIRCUIT SB GC 21779 10 TRACK - LED FIXTURE WITH SNOOT - 31N 75MM - BLACK - 1100LM FLOOD SB GC INTEGRATED LED TROFFER 23055 6 TROFFER - LED RECESSED - 24X481N 60OX1200MM - WHITE - 4000LM SB GC INTEGRATED LED PLUMBING FIXTURE SCHEDULE - "P" DESIGN ID COUNT DESCRIPTION FURN. BY I INST. BY COMMENTS DRAIN 10294 7 DRAIN - FLOOR SINK SQUARE - 51N 125MM S13 IGC 10726 8 DRAIN - GRATE HALF SQUARE - 121N 305MM ISB IGC FAUCET 10152 1 FAUCET - DOUBLE LABORATORY WITH BENT RISER SPOUT SB GC 10153 4 FAUCET - WATER TOWER - 121N 305MM SB GC 10215 2 FAUCET - DOUBLE LABORATORY WITH SWING SPOUT SB GC 10597 2 FAUCET - SINGLE HANDLE SB GC 11003 2 FAUCET - METERED SB GC 22642 3 FAUCET - INSTANTHOT SYSTEM 2 BUTTON WITH BOILER AND BRACKET SB GC KIT INCLUDES FONT, UNDERCOUNTER BOILER AND BOILER BRACKET FOR SIDE PANEL MOUNTING. BRACKET CAN BE FLOOR MOUNTED USING SET OF (4) STAINLESS STEEL LEGS, ORDERED SEPARATELY THROUGH VENDOR. FILTER 23355 1 FILTER - FILTRATION BOOSTER PUMP S13 IGC OTHER 21669 1 GREASE INTERCEPTOR GB75 IGC IGC SINK 10549 1 SINK - RINSE DROP IN SST - 12X201N 305X510MM SB GC 17565 1 SINK - RINSE WITH DRAINBOARD - 15X271N 38OX685MM SB GC 18743 1 SINK - WATER FILLING STATION - 36X241N 915X610MM SB GC 22768 2 SINK - COUNTERTOP RINSER WITH WATER TOWER - 26X91N 660X235MM SB GC _F STARBUCKS" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD !im GRAPHITE GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 9335 REGIS D MARTIN LEE HILL STATE OF WASHINGTON RECEIVED = May 06 2024 O CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O 06 Q O co w 0 LU O G 7 � n Q v/ z0 < Z U U W O LU ° LU O ° 0 0- W oo o_ rn W STORE #: 3232 PROJECT #: 03168-076 ISSUE DATE: 4/19/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRAPHITE Revision Schedule Rev Date By Description SHEET TITLE: LIGHTING AND PLUMBING SCHEDULES SCALE: AS SHOWN SHEET NUMBER: 1603 SYMBOL MODIFIERS (INCLUDING COMBINATIONS), ACRONYMS, AND ABBREVIATONS GENERAL SYMBOL MODIFIERS (APPLY TO ALL) SWITCHES AND CONTROLS MODIFIERS GENERAL ACRONYMS AND ABBREVIATIONS +XX" MOUNTING HEIGHT TO CENTER OF BOX 2 DPST AHJ AUTHORITY HAVING JURISDICTION (OVERRIDES DEFAULT MOUNTING HEIGHT) 3 THREE—WAY AFF ABOVE FINISHED FLOOR ACH 6 INCHES ABOVE COUNTERTOP/BACKSPLASH 4 FOUR—WAY AFG ABOVE FINISHED GRADE TO CENTER OF BOX a,b,c... CONTROL AND LOAD ASSOCIATION EGC EQUIPMENT GROUNDING CONDUCTOR EM EMERGENCY D DIMMER ERMS ARC ENERGY REDUCING MAINTENANCE SWITCH GFCI GROUND —FAULT CIRCUIT INTERRUPTER DTC SPOT, CENTER OFF, MAINTAINED CONTACT FTL FEED —THROUGH LUGS (SUBFEED LUGS ARE (4 TO 6 MILLIAMP TRIP) DTM SPOT, CENTER OFF, MOMENTARY CONTACT ALSO ACCEPTABLE) H HORIZONTAL MOUNT F BOX COVER UNIT, BUSSMANN SSU SERIES GEC GROUNDING ELECTRODE CONDUCTOR PT POKE —THROUGH G GLOW HANDLE (HANDLE GLOWS WHEN GFPE GROUND —FAULT PROTECTION OF EQUIPMENT WP WEATHERPROOF SWITCH IS OFF) GNO GROUND K KEY OPERATED N.F. NON —FUSED RECEPTACLE MODIFIERS LV LOW VOLTAGE NEC NATIONAL ELECTRICAL CODE (NFPA 70) CH CLOCK HANGER LVD LOW VOLTAGE DIMMER NIC NOT IN CONTRACT CR CONTROLLED M MANUAL MOTOR CONTROLLER WITH NL NIGHTLIGHT HIS HOSPITAL GRADE OVERLOAD HEATER ST SHUNT TRIP IG ISOLATED GROUND OR OVERRIDE WITH TIMER UNO UNLESS NOTED OTHERWISE SP SURGE PROTECTION OS1 SINGLE —RELAY OCCUPANCY SENSOR SPST SINGLE POLE, SINGLE THROW SR SHOW WINDOW. MOUNTED WITHIN 18 INCHES OS2 DUAL —RELAY OCCUPANCY SENSOR DPST DOUBLE POLE, SINGLE THROW OF TOP OF SHOW WINDOW OSD DIMMING OCCUPANCY SENSOR 3PST THREE POLE, SINGLE THROW TR TAMPER —RESISTANT P PILOT LIGHT (PILOT ON WHEN SWITCH IS ON) 4PST FOUR POLE, SINGLE THROW USB DEVICE WITH USB PORT(S) SB SWITCH BANK (GANGED SWITCHES) SPOT SINGLE POLE, DOUBLE THROW T TIMER DPDT DOUBLE POLE, DOUBLE THROW 3PDT THREE POLE, DOUBLE THROW 4PDT FOUR POLE, DOUBLE THROW NO NORMALLY OPEN NC NORMALLY CLOSED ELECTRICAL SYMBOL LEGEND (SOME MAY NOT BE USED) SYMBOL DESCRIPTION SYMBOL DESCRIPTION WALL MOUNTED SINGLE RECEPTACLE, NEMA 5-20R E FLUSH FLOOR MOUNTED SINGLE RECEPTACLE, NEMA 5-20R WALL MOUNTED DUPLEX RECEPTACLE ® FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE WALL MOUNTED DEDICATED DUPLEX RECEPTACLE ® FLUSH FLOOR MOUNTED DEDICATED DUPLEX RECEPTACLE WALL MOUNTED DUPLEX RECEPTACLE, ONE RECEPTACLE SWITCHED OR SPLIT —WIRED ® FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE, SPLIT —WIRED WALL MOUNTED QUADRUPLEX RECEPTACLE ® FLUSH FLOOR MOUNTED QUADRUPLEX RECEPTACLE WALL MOUNTED DEDICATED QUADRUPLEX RECEPTACLE ® FLUSH FLOOR MOUNTED DEDICATED QUADRUPLEX RECEPTACLE a WALL MOUNTED QUADRUPLEX RECEPTACLE, SPLIT —WIRED ® FLUSH FLOOR MOUNTED QUADRUPLEX RECEPTACLE, SPLIT —WIRED LiWALL -0 MOUNTED SPECIAL RECEPTACLE, ❑® FLUSH FLOOR MOUNTED SPECIAL RECEPTACLE, U NEMA CONFIGURATION AS NOTED NEMA CONFIGURATION AS NOTED WALL MOUNTED RANGE RECEPTACLE, ABOVE FLOOR SERVICE FITTING, HUBBELL #SC3098A OR D w NEMA 14-50R UNLESS INDICATED OTHERWISE EQUAL; NEMA CONFIGURATION AS NOTED U Li • �C EILING MOUNTED SINGLE RECEPT CLE, NEMA 5-20R ®C CEILING MOUNTED QUADRUPLEX RECEPTACLE (C=FLUSH CEILING, DC=DROPCOF (C=FLUSH CEILING, DC=DROPCORD) ®C CEILING MOUNTED DUPLEX RECEPTACLE ®C CEILING MOUNTED DEDICATED QUADRUPLEX RECEPTACLE (C=FLUSH CEILING, DC=DROPCORD) (C=FLUSH CEILING, DC=DROPCORD) ®C DEDICATED DU RECEPTACLE �CILFLUSHOCEI ®C �CIUFLUSHOCEILN6,QDCDDROPCORD�CEPTACLE, SPLIT —WIRED CEILING, ®C OCEILING,DDCLDROPCORDCEPT CLE, SPLIT —WIRED ) CONFIGURATION CEIEIC (CTFWSHSPECIAL (CILFLUSHING ASLING NOTED CEILING,CDCTDROPCORDACLE '-�"--' MULTI —OUTLET ASSEMBLY J CORD AND PLUG V WALL MOUNTED JUNCTION/OUTLET BOX mC CEILING MOUNTED JUNCTION/OUTLET BOX w x m FLUSH FLOOR MOUNTED JUNCTION/OUTLET BOX O JUNCTION BOX MOUNTED ABOVE CEILING SWITCH, SPST UNLESS INDICATED OTHERWISE, HORSEPOWER El PUSHBUTTON STATION, ONE BUTTON RATED WHEN USED IN CONJUNCTION WITH MOTORS OS CEILING MOUNTED OCCUPANCY SENSOR 0 PUSHBUTTON STATION, TWO BUTTON o �OS WALL MOUNTED OCCUPANCY SENSOR 0 PUSHBUTTON STATION, THREE BUTTON a- Z S CEILING MOUNTED PHOTOSENSOR L[j SAFETY SWITCH, CHARACTERISTICS AS INDICATED 0 U CEILING MOUNTED MOTION SENSOR DISCONNECT SWITCH PROVIDED BY EQUIPMENT MANUFACTURER 0 INTEGRAL WITH EQUIPMENT z a TC AUTOMATIC TIMECLOCK L0 ENCLOSED CIRCUIT BREAKER, CHARACTERISTICS AS INDICATED Ld PC PHOTOCELL ® MAGNETIC MOTOR STARTER ~ ® RELAY COMBINATION MAGNETIC MOTOR STARER AND DISCONNECT Ln SWITCH, CHARACTERISTICS AS INDICATED © CONTACTOR VFD VARIABLE FREQUENCY DRIVE ALCR UL 924 AUTOMATIC LOAD CONTROL RELAY- HUBBELL CONTROL SYSTEMS #ALCR1277 & EQUAL GTD UL 1008 BRANCH CIRCUIT EMERGENCY LIGHTING TRANSFER SWITCH; BODINE #GTD20A OR EQUAL Q z BELL CHIME ui I C Y BUZZER O l ROTATING BEACON U) - WALL MOUNTED TELEPHONE OUTLET, *P WALL MOUNTED DATA OUTLET; 0 DENOTES NUMBER OF TELEPHONE PORTS *D DENOTES NUMBER OF DATA PORTS FLUSH FLOOR MOUNTED TELEPHONE OUTLET; *P ❑l FLUSH FLOOR MOUNTED DATA OUTLET; *D U❑ DENOTES NUMBER OF TELEPHONE PORTS DENOTES NUMBER OF DATA PORTS Z CEILING MOUNTED TELEPHONE OUTLET; *P ❑� CEILING MOUNTED DATA OUTLET; *D �❑C DENOTES NUMBER OF TELEPHONE PORTS C DENOTES NUMBER OF DATA PORTS 0 v WALL DATA OUTLET, OUMBIER�OF Efl FLUSH FLOOR MOUNTED TION TELEPHONE U P/ DMD NOES NOUNTED TELEPHOON NE/DATANE PORTS OF ELEPHONE/DADTADATA OUTLET, *P/*D DENOESCNUMBER PORTS w � (( WAP )) WIRELESS ACCESS POINT ❑� C CEILING MOUNTED COMBINATION TELEPHONE AND DATA OUTLET; *P *D DENOTES NUMBER OF TELEPHONE/DATA PORTS CIRCUITRY, CONCEALED IN WALL OR CEILING ■P POWER POLE CIRCUITRY, CONCEALED IN OR UNDER FLOOR ■T TELECOMMUNICATIONS POLE U D' CIRCUITRY, EXPOSED ETP TWO —CHANNEL TELECOMMUNICATIONS AND POWER POLE U o CIRCUIT HOMERUN. THE NUMBER OF ARROWS INDICATES THE ---UCP--- UNDERCARPET FLAT CONDUCTOR CABLE WIRING SYSTEM, POWER a NUMBER OF CIRCUITS. TWO WIRES UNLESS NOTED OTHERWISE; FISSREQU EA GROUND ---UCT--- UNDERCARPET FLAT CONDUCTOR CABLE WIRING SYSTEM, V) WIRE RED BUT NOT NDICATED. 7 NDICA TELEPHONE a 3 ISOLATED GROUND CONDUCTOR. ---UCD--- UNDERCARPET FLAT CONDUCTOR CABLE WIRING SYSTEM, DATA w U ] CONDUIT STUB WIRE LOOP FOR FUTURE CONNECTION, 10'-0" MINIMUM SLACK D CONDUIT/CIRCUIT BREAK AND CONTINUED ELSEWHERE VERTICAL CONDUIT/CIRCUIT METER AND SOCKET MOTOR ow Q ® LIGHTING AND APPLIANCE PANELBOARD, SURFACE MOUNTED XX RPS REMOTE LIGHTING P WER SUPPLY TRANSFORMER; (XX = WATT RATING w U LIGHTING AND APPLIANCE PANELBOARD, FLUSH MOUNTED XX® TRACK LIGHTING END FEED; XX = CURRENT LIMITER RATING, IF APPLICABLE) ® OTHER EQUIPMENT AS NOTED TR LOW VOLTAGE CONTROL TRANSFORMER WALL MOUNTED CCTV CAMERA MC CEILING MOUNTED CCTV CAMERA MTV CCTV MONITOR OUTLET CEILING MOUNTED CCTV CAMERA WITH DOME COVER CACP CONTROLLED ACCESS CONTROL PANEL PE CONTROLLED ACCESS "PUSH TO EXIT" PUSHBUTTON In w ES CONTROLLED ACCESS ELECTRIC DOOR STRIKE CR CONTROLLED ACCESS CARD READER U) >_ cn DR CONTROLLED ACCESS ELECTRIC DOOR STRIKE RELEASE SENSOR BR CONTROLLED ACCESS BIOMETRIC READER ML CONTROLLED ACCESS MAGNETIC LOCK CKP CONTROLLED ACCESS KEYPAD w BCP INTRUSION DETECTION CONTROL PANEL DC INTRUSION DETECTION DOOR CONTACT Ln FB_KPj INTRUSION DETECTION SECURITY KEYPAD GB INTRUSION GLASS BREAK SENSOR M0 CEILING MOUNTED INTRUSION DETECTION MOTION SENSOR EEL CEILING MOUNTED INTRUSION GLASS BREAK SENSOR ltLM WALL MOUNTED INTRUSION DETECTION MOTION SENSOR HU INTRUSION HOLD—UP BUTTON © 2022 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 RECEIVED May 06 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT # Revision Schedule Rev Date By Description ELECTRICAL LEGEND SHEET NUMBER: E001 SITE SCHEDULE - "Y" DESIGN IDI COUNT I DESCRIPTION EXTERIOR MENU 23071 1 SIGN - DIRECTIONAL EXIT ONLY ILLUM DS - EXISTING FOUNDATION -441N 1120MM © 2022 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 RECEIVED May 06 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT # Revision Schedule Rev Date By Description SHEET TITLE: ELECTRICAL SHEET NUMBER: E100 N ELECTRICAL KEYED NOTES PROVIDE POWER AND DATA DEVICES FOR DIGITAL MENU BOARDS. COORDINATE EXACT LOCATION WITH STARBUCKS PROJECT MANAGER PRIOR TO ROUGH -IN. ROUTE CONTROL CABLES IN CONDUIT FROM CONTROL PANEL TO DIVERTER. FURNISH DUCT SMOKE DETECTOR AND RELAY FOR HVAC UNIT SUPPLY FAN SHUTDOWN, FOR INSTALLATION BY THE MECHANICAL CONTRACTOR. DUCT SMOKE DETECTOR SHALL BE SYSTEM SENSOR #D4120 OR EQUAL. PROVIDE 120 VOLT WIRING TO THE DUCT SMOKE DETECTOR AND CONNECT TO SPARE 20 AMP, 1 POLE CIRCUIT BREAKER WITH HANDLE LOCK -ON ACCESSORY. ALSO PROVIDE A SYSTEM SENSOR #RTS2-AOS, OR EQUAL, REMOTE TEST STATION / MULTI -SIGNALING ACCESSORY AND COORDINATE INSTALLATION LOCATION WITH AUTHORITY HAVING JURISDICTION AND OWNER PRIOR TO ROUGH -IN. PROVIDE ALL FINAL WIRING FOR A COMPLETE AND FUNCTIONAL SYSTEM. ® DISCONNECT SWITCH AND WEATHERPROOF GFCI SERVICE RECEPTACLE ARE PROVIDED BY EQUIPMENT MANUFACTURER. INTEGRAL WITH EQUIPMENT. PROVIDE CIRCUITS AND FINAL CONNECTIONS AS INDICATED. ELECTRICAL RELOCATION NOTES OFOR EACH RELOCATED EQUIPMENT, MATCH RECEPTACLE NEMA CONFIGURATION AND WIRE GAUGE, EXTED BRANCH CIRCUIT AS REQUIRED TO COMPLETE THE CONNECTION AND IF NOT ALREADY PRESENT, PROVIDE NEW GFCI CIRCUIT BREAKER. DO NOT ABANDON EXISTING WORK. ORELOCATED REACH -IN FREEZER. ORELOCATED REACH -IN REFRIGERATOR. ORELOCATED 2 DR REACH -IN FREEZER. ORELOCATED 2 DR REACH -IN REFRIGERATOR. ORELOCATED DISHWASHER. POWER AND SYSTEMS PLAN scale: 1 /4" = 1'-0" Appliance Electrical Connection Schedule Mark Equipment Description Voltage System Load Load Units Cord and PIuq Ratinq Connection Type Rough -In Height 17564 RINSER SENSOR 120V 1 Phase 2 Wire 180.0 VA Watts 5-15P Receptacle 28 18743 HOT WATER DISPENSER 120V 1 Phase 2 Wire 1500.0 VA Watts 5-15P Receptacle 28 21679 NITRO GENERATOR 120V, 1 Phase, 2 Wire 6.0 Amps 5-15P Receptacle 28 22642 HOT WATER DISPENSER 120V, 1 Phase, 2 Wire 1500.0 VA Watts 5-15P Receptacle 28 22885 CLOVER BREWER 120/208V 1 Phase 3 Wire 40.1 Amps 14-50P Receptacle 28 23183 ICE MACHINE 208V 1 Phase 2 Wire 14 Amps 6-20P Receptacle 72 23419 MILK DISPENSER 120V 1 Phase 2 Wire 200 VA Watts 5-15P Receptacle 80 23421 ICE DISPENSER 120V, 1 Phase, 2 Wire 10 Amps 5-15P Receptacle 80 23423 ICE DIVERTER 1 120V 1 Phase 2 Wire 1.5 Amps I 5-15P Receptacle 80 23424 ICE DIVERTER CONTROL PANEL 120V 1 Phase 2 Wire 10 Amps 5-15P Receptacle 80 23444 WARMING WALL 1000 208V, 1 Phase, 2 Wire 28.7 Amps 6-30P Receptacle 28 23442 OVEN 208V 3 Phase 3 Wire 23.6 Am s 15-30P Receptacle 28 ELECTRICAL GENERAL NOTES A. ANY EXISTING CONDITIONS INDICATED IN THIS SET OF DRAWINGS ARE BASED ON INFORMATION PROVIDED BY OTHERS AND POSSIBLE LIMITED FIELD VERIFICATION. ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. B. VISIT THE PROJECT SITE, REVIEW EXISTING CONDITIONS AGAINST THE CONTRACT DOCUMENTS, AND BECOME FAMILIAR WITH THE WORK PRIOR TO BIDDING AND START OF WORK. SIGNING THE CONTRACT IS AN ACKNOWLEDGEMENT THAT THE SITE VISIT HAS BEEN COMPLETED AND THE EXISTING CONDITIONS ARE ACCEPTED. C. ANY EXISTING FIRE ALARM SYSTEM SHALL REMAIN IN OPERATION THROUGHOUT CONSTRUCTION. AUTOMATIC SMOKE DETECTORS IN THE AREA OF CONSTRUCTION SHALL BE DISCONNECTED AND TEMPORARILY REPLACED WITH HEAT DETECTORS WHEN THE SPACE IS STAFFED BY THE CONTRACTOR IN ACCORDANCE WITH THE APPROVED FIRE SAFETY PROCEDURES OF THE OWNER AND THE LOCAL FIRE MARSHAL, BUT SHALL BE REACTIVATED WHENEVER THE SPACE IS NOT OCCUPIED BY THE CONTRACTOR. AUTOMATIC SMOKE DETECTORS SHALL BE PROTECTED FROM DUST AND DIRT ACCUMILATION BY REMOVING THE DEVICE FROM ITS BASE DURING THOSE TIMES WHEN THE SYSTEM IS ALLOWED TO BE OUT OF OPERATION. D. DEMOLISH ANY EXISTING EQUIPMENT, DEVICES, AND LUMINAIRES AS INDICATED AND/OR AS REQUIRED TO ALLOW FOR INSTALLATION AND CONSTRUCTION OF THE NEW WORK. REMOVE ALL EQUIPMENT, DEVICES, LUMINAIRES, CONDUITS, SUPPORTS, HANGERS, ETC. THAT ARE NOT SHOWN AND ARE REQUIRED TO BE REMOVED IN ORDER TO COMPLETE THE NEW WORK. E. ELECTRICAL CIRCUITS THAT ARE TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY. CONDUCTORS SHALL BE REMOVED FROM THE ITEM TO BE DEMOLISHED TO THE SOURCE OVERCURRENT DEVICE. RACEWAYS WHICH ARE INSTALLED IN OR BELOW FLOORS OR WITHIN WALLS MAY BE ABANDONED, BUT ALL OVERHEAD OR EXPOSED RACEWAYS SHALL BE REMOVED. EXPOSED RACEWAYS TO BE ABANDONED SHALL BE REMOVED AND SHALL BE CUT OR CHISELED AT LEAST 2" INTO THE WALL OR FLOOR AND THE OPENING GROUTED SMOOTH. F. MAINTAIN CONTINUITY OF EXISTING CIRCUITS AS REQUIRED TO PROVIDE POWER TO REMAINING EQUIPMENT, DEVICES AND LUMINAIRS THAT ARE NOT BEING REMOVED. G. WHERE THE MECHANICAL DESIGN UTILIZES A PLENUM RETURN AIR CEILING DESIGN, ALL EQUIPMENT AND MATERIALS INSTALLED WITHIN THE PLENUM RETURN CEILING MUST MEET THE FLAME SPREAD AND SMOKE DEVELOPED RATINGS OF 25/50 AND BE APPROVED FOR USE IN PLENUM RETURN CEILINGS. COORDINATED PLENUM CEILING LOCATIONS WITH THE MECHANICAL CONTRACTOR. H. COORDINATE ALL DEVICE LOCATIONS AND CIRCUIT ROUTING WITHIN ANY MILLWORK WITH MILLWORK VENDOR PRIOR TO ROUGH -IN. COORDINATE THE CONNECTIONS OF ALL EQUIPMENT PROVIDED BY OTHERS WITH THE CONTRACTOR PROVIDING THE EQUIPMENT PRIOR TO ROUGH -IN. THIS INCLUDES, BUT IS NOT LIMITED TO, MECHANCIAL EQUIPMENT, KITCHEN EQUIPMENT, AUDIOVISUAL EQUIPMENT, FIRE SUPPRESSION SYSTEM EQUIPMENT, FIRE ALARM EQUIPMENT, ETC. PROVIDE THE APPROPRIATE DISCONNECTING MEANS FOR, AND TO MAKE THE FINAL CONNECTION TO, ANY HARDWIRED EQUIPMENT. THE ELECTRICAL CONTRACTOR IS ALSO RESPONSIBLE TO PROVIDE AN APPROPRIATE CORD AND PLUG FOR ANY CORD AND PLUG CONNECTED EQUIPMENT THAT IS NOT EQUIPPED WITH AN INTEGRAL CORD AND PLUG. J. SEE PANEL SCHEDULES FOR INFORMATION ON CIRCUITS THAT ARE TO BE ROUTED THROUGH CONTACTORS OR RELAYS FOR CONTROL. K. ALL LUGS, TERMINALS, ETC. IN ELECTRICAL DISTRIBUTION EQUIPMENT SHALL BE LISTED FOR A MINIMUM OF 75 DEGREE C CONDITIONS. TERMINATIONS LISTED FOR ONLY 60 DEGREE C CONDITIONS ARE NOT PERMITTED. L. CONDUCTORS #12 AND SMALLER SHALL BE SOLID. CONDUCTORS #10 AWG AND LARGER ARE PERMITTED TO BE STRANDED. M. DEVICES MARKED "EX" ARE EXISTING TO REMAIN IN PLACE. ALL DEVICES WITHIN THE LIMITS OF CONSTRUCTION SHALL BE REPAIRED TO A LIKE -NEW CONDITION AND THOROUGHLY CLEANED. ANY EXISTING DEVICES THAT ARE DAMAGED BEYOND REPAIR SHALL BE REPLACED WITH AN IDENTICAL DEVICE. LEGEND EXISTING NEW WORK NEW TO EXISTING CONNECTION m 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD 1:1221002-�'tiarL�c�.: Ir€;�rur6;r€r Avvr€vetG:11±-lar�+srblackj� GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 = RECEIVED May 06 2024 CITY OF EDMONDS C)DEVELOPMENT SERVICES DEPARTMENT O V_ 06 O 04 Q O/�� KT/ V ) v / v, LIJ Z L�jQ 2 Q z o 0z0 5 < o z U C)O w w aW arnw STORE #: 3232 PROJECT #: 03188-076 ISSUE DATE: 04/15/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRS Revision Schedule Rev Date By Description SHEET TITLE: POWER PLAN AND EQUIP. SCHEDULE SCALE: AS SHOWN SHEET NUMBER: E101 ENLARGED MANAGER'S DESK AND EQUIPMENT RACK POWER AND SYSTEMS PLAN scale: 1 /2" = V-0" N N 0 W ELECTRICAL KEYED NOTES VERIFY EXISTING CIRCUIT IN FIELD. INTERCEPT AND EXTEND EXISTING BRANCH CIRCUIT AS REQUIRED TO RECONNECT TO EXISTING CIRCUIT SERVING THIS DEVICE AND/OR EQUIPMENT. ENLARGED ENGINE POWER AND SYSTEMS PLAN scale: 1 /2" = 1'-0" ELECTRICAL PLAN NOTES OFOR EACH RELOCATED EQUIPMENT, MATCH NEMA CONFIGURATION, WIRE GAUGE, PROVIDE RECEPTACLE IF NOT EXISTING AND EXTEND BRANCH CIRCUIT AS REQUIRED TO COMPLETE THE CONNECTION. CIRCUIT NUMBER SHALL MATCH EXISTING. DO NOT ABANDON EXISTING WORK. PROVIDE ADDITIONAL CASEWORK PENETRATIONS AS REQUIRED TO PROVIDE THE FINAL EQUIPMENT CONNECTION. O RELOCATED (4) UNDERCOUNTER REFRIGERATOR. O RELOCATED (2) ESPRESSO O RELOCATED GRINDER. 0RELOCATED (3) CUP LABELER. O RELOCATED DRIVE THRU EQUIPMENT. 0RELOCATED POS EQUIPMENT. ORELOCATED (2) BLENDER. ORELOCATED FOOD CASE. 10 RELOCATED (2) OVEN. 11 RELOCATED MANAGERS DESK ELECTRICAL GENERAL NOTES A. ANY EXISTING CONDITIONS INDICATED IN THIS SET OF DRAWINGS ARE BASED ON INFORMATION PROVIDED BY OTHERS AND POSSIBLE LIMITED FIELD VERIFICATION. ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. B. VISIT THE PROJECT SITE, REVIEW EXISTING CONDITIONS AGAINST THE CONTRACT DOCUMENTS, AND BECOME FAMILIAR WITH THE WORK PRIOR TO BIDDING AND START OF WORK. SIGNING THE CONTRACT IS AN ACKNOWLEDGEMENT THAT THE SITE VISIT HAS BEEN COMPLETED AND THE EXISTING CONDITIONS ARE ACCEPTED. C. ANY EXISTING FIRE ALARM SYSTEM SHALL REMAIN IN OPERATION THROUGHOUT CONSTRUCTION. AUTOMATIC SMOKE DETECTORS IN THE AREA OF CONSTRUCTION SHALL BE DISCONNECTED AND TEMPORARILY REPLACED WITH HEAT DETECTORS WHEN THE SPACE IS STAFFED BY THE CONTRACTOR IN ACCORDANCE WITH THE APPROVED FIRE SAFETY PROCEDURES OF THE OWNER AND THE LOCAL FIRE MARSHAL, BUT SHALL BE REACTIVATED WHENEVER THE SPACE IS NOT OCCUPIED BY THE CONTRACTOR. AUTOMATIC SMOKE DETECTORS SHALL BE PROTECTED FROM DUST AND DIRT ACCUMILATION BY REMOVING THE DEVICE FROM ITS BASE DURING THOSE TIMES WHEN THE SYSTEM IS ALLOWED TO BE OUT OF OPERATION. D. DEMOLISH ANY EXISTING EQUIPMENT, DEVICES, AND LUMINAIRES AS INDICATED AND/OR AS REQUIRED TO ALLOW FOR INSTALLATION AND CONSTRUCTION OF THE NEW WORK. REMOVE ALL EQUIPMENT, DEVICES, LUMINAIRES, CONDUITS, SUPPORTS, HANGERS, ETC. THAT ARE NOT SHOWN AND ARE REQUIRED TO BE REMOVED IN ORDER TO COMPLETE THE NEW WORK. E. ELECTRICAL CIRCUITS THAT ARE TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY. CONDUCTORS SHALL BE REMOVED FROM THE ITEM TO BE DEMOLISHED TO THE SOURCE OVERCURRENT DEVICE. RACEWAYS WHICH ARE INSTALLED IN OR BELOW FLOORS OR WITHIN WALLS MAY BE ABANDONED, BUT ALL OVERHEAD OR EXPOSED RACEWAYS SHALL BE REMOVED. EXPOSED RACEWAYS TO BE ABANDONED SHALL BE REMOVED AND SHALL BE CUT OR CHISELED AT LEAST 2" INTO THE WALL OR FLOOR AND THE OPENING GROUTED SMOOTH. F. MAINTAIN CONTINUITY OF EXISTING CIRCUITS AS REQUIRED TO PROVIDE POWER TO REMAINING EQUIPMENT, DEVICES AND LUMINAIRS THAT ARE NOT BEING REMOVED. G. WHERE THE MECHANICAL DESIGN UTILIZES A PLENUM RETURN AIR CEILING DEISGN, ALL EQUIPMENT AND MATERIALS INSTALLED WITHIN THE PLENUM RETURN CEILING MUST MEET THE FLAME SPREAD AND SMOKE DEVELOPED RATINGS OF 25/50 AND BE APPROVED FOR USE IN PLENUM RETURN CEILINGS. COORDINATED PLENUM CEILING LOCATIONS WITH THE MECHANICAL CONTRACTOR. H. COORDINATE ALL DEVICE LOCATIONS AND CIRCUIT ROUTING WITHIN ANY MILLWORK WITH MILLWORK VENDOR PRIOR TO ROUGH -IN. COORDINATE THE CONNECTIONS OF ALL EQUIPMENT PROVIDED BY OTHERS WITH THE CONTRACTOR PROVIDING THE EQUIPMENT PRIOR TO ROUGH -IN. THIS INCLUDES, BUT IS NOT LIMITED TO, MECHANCIAL EQUIPMENT, KITCHEN EQUIPMENT, AUDIOVISUAL EQUIPMENT, FIRE SUPPRESSION SYSTEM EQUIPMENT, FIRE ALARM EQUIPMENT, ETC. PROVIDE THE APPROPRIATE DISCONNECTING MEANS FOR, AND TO MAKE THE FINAL CONNECTION TO, ANY HARDWIRED EQUIPMENT. THE ELECTRICAL CONTRACTOR IS ALSO RESPONSIBLE TO PROVIDE AN APPROPRIATE CORD AND PLUG FOR ANY CORD AND PLUG CONNECTED EQUIPMENT THAT IS NOT EQUIPPED WITH AN INTEGRAL CORD AND PLUG. J. SEE PANEL SCHEDULES FOR INFORMATION ON CIRCUITS THAT ARE TO BE ROUTED THROUGH CONTACTORS OR RELAYS FOR CONTROL. K. ALL LUGS, TERMINALS, ETC. IN ELECTRICAL DISTRIBUTION EQUIPMENT SHALL BE LISTED FOR A MINIMUM OF 75 DEGREE C CONDITIONS. TERMINATIONS LISTED FOR ONLY 60 DEGREE C CONDITIONS ARE NOT PERMITTED. L. CONDUCTORS #12 AND SMALLER SHALL BE SOLID. CONDUCTORS #10 AWG AND LARGER ARE PERMITTED TO BE STRANDED. !� 5 5Ci1na&el e New Yuk• MIeM On®Fe Las MgCes S�Itle Hontlul 800581-0963 wawsd�md�laon m 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD 1?221002-O'tiarL c .: Ir€; rur6;r€r Avvr€vetG:11±-lar�+srblackj GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 = RECEIVED May 06 2024 CITY OF EDMONDS C)DEVELOPMENT SERVICES DEPARTMENT O V_ 06 O 04 O/�� CV) ) v / v, w Z L�jQ 2 Q z o 0 5 z0 <oz U C)O w w a W 01�00 a- a, W STORE #: 3232 PROJECT #: 03188-076 ISSUE DATE: 04/15/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRS Revision Schedule Rev Date By Description SHEET TITLE: ENLARGED POWER AND SYSTEMS PLANS SCALE: AS SHOWN SHEET NUMBER: E102 LUMINAIRE SCHEDULE LAMP LAMP LAMP SELECTED MARK MANUFACTURER CATALOG NUMBER VOLTAGE WATTS MOUNTING QUANTITY DESCRIPTION TYPE BY OTHERS? REMARKS 17796 DOLAN HOSPITALITY 621038 120 23 W GRADE, POLE — INTEGRAL LED YES 4' BLACK TRACK SECTION WITH 19411 JUNO TRAC—MASTER 2—CIRCUIT TRACK 120 — TRACK — — YES JOINER, MINI CONNECTOR AND MINI SECTIONS: TU 4FT BL END FEED (TU 38) 20749 DOLAN ZWS47305—VB-2700K 120 6 W WALL, SURFACE — INTEGRAL LED YES 0-10V DIMMING DRIVER 20750 DOLAN ZWS47321—VB-2700K 120 16.5 W WALL, SURFACE — INTEGRAL LED YES 0-10V DIMMING DRIVER G-25 6 WATT, 20802 SCHOOLHOUSE ISAAC PENDANT —NATURAL BRASS 120 10 W CEILING, SUSPENDED 1 2700K, 525 LED YES LUMENS 21772 ALPHABET NU3—RA—SW-13LM-27K-90—S35— 120 12 W CEILING, RECESSED — INTEGRAL LED YES 0-10V DIMMING DRIVER 120—DIM10—NC—WH—WH NU3—RA—SW-13LM-27K-90—S35— 21772EM ALPHABET 120—DIM10—NC—WH—WH—EM12 120 12 W CEILING, RECESSED — INTEGRAL LED YES 0-10V DIMMING DRIVER 350440-13LM-30K-90-38-120— 21779 BRUCK ELV—SNOOTBK—ECOBK 120 15 W TRACK — INTEGRAL LED YES PHASE DIMMING 0-10V OR PHASE DIMMER DEPENDING 22217 LUMINII LL91STP—MO-27K—SL-0706C—X—F '�VDC 4W/FT COVE — INTEGRAL LED YES ON 30W OR 60W OR 96W POWER SUPPLY CEILING, 23055 TCP DT—F-4—U—ZD-29-27 120 29 W RECESSED/SURFACE — INTEGRAL LED YES 0-10V DIMMING DRIVER 23055EM TCP DT—F-4—U—ZD-29-27—EB 120 1 29 W CEILING, RECESSED — INTEGRAL I LED I YES 0-10V DIMMING DRIVER X22000 I KUZCO I MP95103 120 1 30 W I CEILING, SUSPENDED — INTEGRAL I LED I YES 0-10V DIMMING DRIVER LAMP TYPE CODES: FL=LINEAR FLUORESCENT, CFL=COMPACT FLUORESCENT, IND=INCANDESCENT, MH=METAL HALIDE, HPS=HIGH PRESSURE SODIUM, LED=LIGHT EMITTING DIODE LUMINAIRE SCHEDULE GENERAL NOTES: A. LUMINAIRE SYMBOLS THAT ARE SHOWN HALF —SHADED, OR LABELED "EM", ON THE PLAN(S) INDICATE LUMINAIRES THAT SERVE AS EMERGENCY LIGHTING. UNLESS SERVED BY A CIRCUIT ORIGINATING AT AN EMERGENCY PANELBOARD OR CENTRAL LIGHTING INVERTER, EMERGENCY LIGHTING LUMINAIRES SHALL BE PROVIDED WITH AN EMERGENCY BATTERY TO PROVIDE EMERGENCY ILLUMINATION FOR A MINIMUM OF 90 MINUTES. B. INTEGRAL EMERGENCY BATTERIES SHALL MEET THE FOLLOWING MINIMUM PERFORMANCE REQUIREMENTS UNLESS OTHERWISE INDICATED: — LINEAR FLUORESCENT LUMINAIRES: 1400 LUMENS, MINIMUM, PER LUMINAIRE. — COMPACT FLUORESCENT LUMINAIRES: 1100 LUMENS, MINIMUM, PER LUMINAIRE. — INTEGRATED LED LUMINAIRES RATED 1000 LUMENS OR LESS: 10 WATT, MINIMUM, OUTPUT. — INTEGRATED LED LUMINAIRES RATED GREATER THAN 1000 LUMENS: 20 WATT, MINIMUM, OUTPUT. C. ANY PROPOSED SUBSTITUTIONS FOR LUMINAIRES THAT ARE SELECTED BY OTHERS REQUIRE THE APPROVAL OF THE SPECIFYING ENTITY. N 0 N 0 W U) ELECTRICAL GENERAL NOTES A. ANY EXISTING CONDITIONS INDICATED IN THIS SET OF DRAWINGS ARE BASED ON INFORMATION PROVIDED BY OTHERS AND POSSIBLE LIMITED FIELD VERIFICATION. ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. B. VISIT THE PROJECT SITE, REVIEW EXISTING CONDITIONS AGAINST THE CONTRACT DOCUMENTS, AND BECOME FAMILIAR WITH THE WORK PRIOR TO BIDDING AND START OF WORK. SIGNING THE CONTRACT IS AN ACKNOWLEDGMENT THAT THE SITE VISIT HAS BEEN COMPLETED AND THE EXISTING CONDITIONS ARE ACCEPTED. C. DEMOLISH ANY EXISTING EQUIPMENT, DEVICES, AND LUMINAIRES AS INDICATED AND/OR AS REQUIRED TO ALLOW FOR INSTALLATION AND CONSTRUCTION OF THE NEW WORK. REMOVE ALL EQUIPMENT, DEVICES, LUMINAIRES, CONDUITS, SUPPORTS, HANGERS, ETC. THAT ARE NOT SHOWN AND ARE REQUIRED TO BE REMOVED IN ORDER TO COMPLETE THE NEW WORK. D. ELECTRICAL CIRCUITS THAT ARE TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY. CONDUCTORS SHALL BE REMOVED FROM THE ITEM TO BE DEMOLISHED TO THE SOURCE OVERCURRENT DEVICE. RACEWAYS WHICH ARE INSTALLED IN OR BELOW FLOORS OR WITHIN WALLS MAY BE ABANDONED, BUT ALL OVERHEAD OR EXPOSED RACEWAYS SHALL BE REMOVED. EXPOSED RACEWAYS TO BE ABANDONED SHALL BE REMOVED AND SHALL BE CUT OR CHISELED AT LEAST 2" INTO THE WALL OR FLOOR AND THE OPENING GROUTED SMOOTH. E. MAINTAIN CONTINUITY OF EXISTING CIRCUITS AS REQUIRED TO PROVIDE POWER TO REMAINING EQUIPMENT, DEVICES AND LUMINAIRS THAT ARE NOT BEING REMOVED. F. WHERE THE MECHANICAL DESIGN UTILIZES A PLENUM RETURN AIR CEILING DESIGN, ALL EQUIPMENT AND MATERIALS INSTALLED WITHIN THE PLENUM RETURN CEILING MUST MEET THE FLAME SPREAD AND SMOKE DEVELOPED RATINGS OF 25/50 AND BE APPROVED FOR USE IN PLENUM RETURN CEILINGS. COORDINATE PLENUM CEILING LOCATIONS WITH THE MECHANICAL CONTRACTOR. LUMINAIRES THAT ARE MANUFACTURED WITH A METAL HOUSING MEET THIS REQUIREMENT AND ARE NOT REQUIRED TO BE PLENUM RATED UNLESS INDICATED OTHERWISE. G. SEE PANEL SCHEDULES FOR INFORMATION ON CIRCUITS THAT ARE TO BE ROUTED THROUGH CONTACTORS OR RELAYS FOR CONTROL. H. PRESERVE THE FIRE RATING OF ANY FIRE -RATED CEILING ASSEMBLIES BY PROVIDING THE APPROPRIATE FIRE -RATED LUMINAIRE TENTS AS MANUFACTURED BY TENANT OR NELSON FIRESTOP OR BY BUILDING FIRE -RATED ENCLOSURES AROUND EACH LUMINAIRE THAT IS RECESSED INTO THE FIRE -RATED ASSEMBLY. COORDINATE FIRE -RATED CEILING ASSEMBLY LOCATIONS WITH THE ARCHITECTURAL DRAWINGS. I. ALL LUGS, TERMINALS, ETC. IN ELECTRICAL DISTRIBUTION EQUIPMENT SHALL BE LISTED FOR A MINIMUM OF 75 DEGREE C CONDITIONS. TERMINATIONS LISTED FOR ONLY 60 DEGREE C CONDUCTORS ARE NOT PERMITTED. J. CIRCUITS SERVING EMERGENCY LIGHTING EQUIPMENT SUCH AS EMERGENCY BATTERIES SHALL NOT SHARE A NEUTRAL (SHALL NOT BE PART OF A MULTIWIRE BRANCH CIRCUIT) WITH ANY OTHER CIRCUIT. PROVIDE A SEPARATE NEUTRAL FOR EVERY CIRCUIT THAT SERVES EMERGENCY LIGHTING. K. ALTHOUGH NOT SPECIFICALLY SHOWN, THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL REQUIRED LOW VOLTAGE WIRING AND DATA CABLING, INCLUDING ALL 0-10V CONTROL WIRING WHERE APPLICABLE, PER THE MANUFACTURER'S RECOMMENDATIONS, FOR A COMPLETE, FUNCTIONAL LIGHTING CONTROL SYSTEM. L. LUMINAIRES MARKED "EX" ARE EXISTING LUMINAIRES THAT ARE TO REMAIN IN PLACE. ALL EXISTING LUMINAIRES WITHIN THE LIMITS OF CONSTRUCTION SHALL BE REPAIRED TO A LIKE -NEW CONDITION, THOROUGHLY CLEANED, AND RELAMPED. ANY EXISTING LUMINAIRES THAT ARE DAMAGED BEYOND REPAIR SHALL BE REPLACED WITH AN IDENTICAL LUMINAIRE. K. LUMINAIRES MARKED "RR" ARE EXISTING LUMINAIRES THAT ARE TO BE OR HAVE BEEN RELOCATED. ALL LUMINAIRES DESIGNATED FOR RELOCATION SHALL BE DISCONNECTED FROM EXISTING BRANCH CIRCUIT, REMOVED FROM EXISTING AREA, STORED, REPAIRED TO A LIKE -NEW CONDITION, INSTALLED IN REMODELED AREA, RECONNECTED, THOROUGHLY CLEANED, AND RELAMPED. ANY RELOCATED LUMINAIRES THAT ARE DAMAGED BEYOND REPAIR SHALL BE REPLACED WITH AN IDENTICAL LUMINAIRE. 101 ELECTRICAL PLAN NOTES RELOCATED SWITCHBANK. PROVIDE ADDITIONAL SWITCHES PER SWITCHBANK SCHEDULE. LOWERCASE LETTERS ADJACENT TO THE LUMINAIRES ON PLANS CORRESPOND TO THE ASSOCIATED SWITCH ON THE SWITCHBANK SCHEDULE. CONFIRM SWITCHBANK WILL FIT WITHIN THIS DESIGNATED AREAAND STACK MULTIPLE SWITCHBANKS, WITH FEWER GANGS, AT THIS LOCATION IF A SINGLE SWITCHBANK WILL NOT FIT WITHIN THIS DESIGNATED AREA. O INSTALL THIS LUMINAIRE'S REMOTE LOW VOLTAGE LIGHTING POWER SUPPLY/ TRANSFORMER (RPS) IN AN INCONSPICUOUS, ACCESSIBLE LOCATION AND PROVIDE FINAL CONNECTION TO LUMINAIRE. COORDINATE MOUNTING LOCATION OF RPS WITH OWNER PRIOR TO ROUGH -IN. THE LENGTH OF CONDUCTORS BETWEEN RPS AND ASSOCIATED LUMINAIRE SHALL NOTE EXCEED MANUFACTURER'S RECOMMENDATIONS FOR MAXIMUM CONDUCTOR LENGTH. RPS DESIGNATIONS INDICATED ADJACENT TO LUMINAIRES CORRESPOND TO THE ASSOCIATED RPS SUPPLYING THE LUMINAIRE. SWITCHBANK "SB1" SCHEDULE SWITCH TAG ZONE DESCRIPTION CONTROL TYPE a CAFE/VESTIBULE LIGHTS LINE VOLTAGE DIMMER b CAFE/VESTIBULE PENDANTS/SCONCES SPST TOGGLE SWITCH C BACK ENGINE LINE VOLTAGE DIMMER d FRONT ENGINE LINE VOLTAGE DIMMER e WORKROOM LIGHTS 3 WAY LINE VOLTAGE DIMMER f VESTIBULE STRIP LIGHT SPST TOGGLE SWITCH GENERAL NOTES: A. PROVIDE BOX PARTITIONS BETWEEN CONTROLS OF DIFFERING VOLTAGES. SWITCHBANK "SB2" SCHEDULE SWITCH TAG ZONE DESCRIPTION CONTROL TYPE 9 ENGINE STRIP LIGHTS LINE VOLTAGE DIMMER h ENGINE PENDANT SPST TOGGLE SWITCH i CAFE RIGHT TRACK LINE VOLTAGE DIMMER k ICAFe LEFT TRACK I LINE VOLTAGE DIMMER GENERAL NOTES: A. PROVIDE BOX PARTITIONS BETWEEN CONTROLS OF DIFFERING VOLTAGES. ,v IVt II /V t/\IJ 111V& (,U1wVLC. 11V1V Y ��M�Mc�On®Fe�La m 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD 1?221002-�'tiarL�c�.: Ir€4�rur6;r€r Avvr€vetG:lY±-la,�+srblackj� GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 = RECEIVED May 06 2024 CITY OF EDMONDS C)DEVELOPMENT SERVICES DEPARTMENT O V_ 06 O 04 Q O/�� KT/ V ) v / v, w Z L�jQ 2 z 0 (� z0 Qoz wLu � C) a W a a, w STORE #: 3232 PROJECT #: 03188-076 ISSUE DATE: 04/15/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRS Revision Schedule Rev Date By Description SHEET TITLE: LIGHTING PLAN SCALE: AS SHOWN SHEET NUMBER: E103 8 7 6 5 4 3 2 1 EQUIPMENT CONTROL PAC (ECP) REMOTE SENSOR IN CONDITIONED AREA USE SINGLE SENSOR PER ECP/HVAC SYSTEM MOUNTED INSIDE HVAC SYSTEM GENERAL NOTES PICK SENSOR TYPE BY LOCATION 0 1. SURVEYOR ENERGY MANAGEMENT SYSTEM HARDWARE IS SUPPLIED BY STARBUCKS. O E m RS410 WALL MOUNT RS420 DROP DOWN m USE IN FOH ONLY USE IN BOH ONLY 2. DRAWING FOR GENERAL INFORMATION, DESIGN INTENT, AND COORDINATION ONLY. 3. LOCAL BUILDING CODES TAKE PRECEDENCE OVER THIS DOCUMENT. D PHOTOCELL MOUNTED • O • O O m 4. NOT ALL WIRING IS SHOWN ON THIS DRAWING. FOR CLARITY, ONLY ONE EXAMPLE D OUTDOORS, TYPICALLY FJ �FF�-� o OF EACH TYPE OF DEVICE IS SHOWN. ON ONE HVAC C-UNICAIpNS ./O ANDO PUTS\. EC0N 7ER ERMOSiAT umux I I 5. RE[ -ER I U I HE SURVEYOR IN5IALLAI ION IN51 RU(;I IONS FOR EAUH UOMPONEN MOTION DETECTORS 1 OR MORE AS NEEDED 0 0 � � � 0 � p pp QH�1Y �xH�DN�DNz� 0 � 0 pp ®„ ODD< Y I I I FOR DETAILED WIRING AND ADDITIONAL CRITICAL INFORMATION. �� SURVEYOR (TYPICALLY 2 REQUIRED) _ ® I I 6. CAUTION! INSTALLATION REQUIRES THE REMOVAL OF SAFETY COVERS AND RS-485 COMM EXPOSE THE INSTALLER TO HIGH VOLTAGE AND ELECTRICAL HAZARDS. ECP POWER & CONNECT 5 EQUIPMENT — — — USE OF A LICENSED ELECTRICIAN IS REQUIRED. FOLLOW ALL APPROPRIATE P�SHSE�R� HVAC CONTROL HEALTH SENSORS AND SAFETY PRECAUTIONS. ADDITIONAL SAFETY INFORMATION IS IN THE � BUoo 00 5 � WIRING 1 REMOTE SENSOR SURVEYOR INSTALLATION MANUALS. SURVEYOR M 7. USE WALL MOUNT REMOTE SENSOR IN FRONT OF HOUSE. MOUNT ON INSIDE WALL SURV LIGHTING CONTROL BOARD SURV COMM THERMOSTAT COMMUNICATION 4 TO 5 FT AFF. AVOID AREAS WITH DIRECT AIRFLOW FROM SUPPLY REGISTERS. AND POWER WIRING 8. USE A DROP DOWN REMOTE SENSOR IN BACK OF HOUSE. THE SENSOR CLIPS TO THE T-BAR GRID AND ADJUSTED SO THE BOTTOM OF THE SENSOR IS 8 TO 9 FT AFF. ALLOW 2 FT OF CLEARANCE FROM METRO SHELVING AND AVOID AREAS WITH DIRECT AIRFLOW FROM SUPPLY REGISTERS. SURVEYOR LIGHTING CONTROL PANEL BUILT IN CONTACTORS ® THERMOSTAT TERMINAL - 9. FOR SURVEYOR EMS TECHNICAL SUPPORT AND SYSTEM COMMISSIONING, PLEASE CONNECT TO LIGHTING CIRCUITS PER ZONES ON ELECTRICAL PLANS THERMOSTATS GROUPED IN CONTACT SURVEYOR TECHNICAL SUPPORT, (855) 647-7660, OPTION 1 OR EMAIL C r--- — — — — — — — — — — — — — — ® MANAGERS WORKSTATION AREA NCSSC.VENSTAR@SYLVANIA.COM. HOURS 6:OOAM TO 8:OOPM PACIFIC, MON-FRI. C 00 00 zr 0000000 O ;'.❑❑ ❑❑ A ❑❑00 00 00 00 00 C-1 C-2 C-3 C-3A C-4 C-4A NOTES: INTERIOR INTERIOR EXTERIOR EXTERIOR PARKING PARKING 1. OUTDOOR TEMPERATURE SENSOR CONNECTED TO ONE ECP ONLY PER LOCATION. L WORK SALES— SIGN SIGN — SITE — SITE — — — — — FACE NORTH WHEN POSSIBLE. 2. SEE GENERAL NOTES 7 AND 8 FOR REMOTE SENSOR MOUNTING LOCATION DETAILS. LIGHTING CONTROL HVAC CONTROLS DATA CONCENTRATOR DATA CONCENTRATOR 4 ECP THERMOSTAT SURVEYOR ® suavEvcH SURVEYOR EMS COMPONENTS VENSTAR PART SBUX ITEM # DESCRIPTION QUANTITY LCP401 011029483 LIGHTING CONTROL PANEL 1 DC400 011029485 DATA CONCENTRATOR 1 OTS400 011029487 OUTDOOR TEMPERATURE SENSOR 1 ECP400 011029489 EQUIPMENT CONTROL PAC 1 PER HVAC CT414 011029490 COMMUNICATING THERMOSTAT 1 PER HVAC SP400 011029491 SENSOR PAC 1 PER HVAC RS410 011029492 WALL MOUNT REMOTE SENSOR 1 PER FOH HVAC RS420 011050767 NARROW DROP DOWN SENSOR 1 PER BOH HVAC MD400 011029497 ADDITIONAL MOTION DETECTOR AS NEEDED CO° O ® G suRVEvoR v FIRST HVAC SYSTEM. TTT0 BETHERNET (�_O) FOH STYLE SENSOR SHOWN. B TO NETWORK SEE GENERAL NOTES 7 AND 8 FOR 0 o SENSOR MOUNTING LOCATION. REMOTE SENSOR CO 0 SECOND HVAC SYSTEM. SURVEYOR ECP THERMOSTAT REPEAT AS NECESSARY. BOH STYLE SENSOR SHOWN. 000 000 0 00 SURVEYO® ®o SEE GENERAL NOTES 7 AND 8 FOR C SENSOR MOUNTING LOCATION. DATA CONCENTRATOR MULTIPLE ECP'S MAY BE POWER SUPPLY CONNECT ETHERNET CABLE TO LAN REMOTE COMBINED ON A SINGLE SURVEYOR RS-485 COMM PORT #6 ON ROUTER IN DATA RACK SENSOR DC PORT WHEN MORE THAN CONNECT TO ALL DEVICES U 3 ECP'S ARE USED. HOME -RUN WHEN POSSIBLE CD 2 6 O !Q9 CDSURVEYOR LIGHTING CONTROL PANEL LAN Comm AOIna aMnC_ MOTION SENSORS ® ® 1 OR MORE AS A NECESSARY A CAT-5 ETHERNET VENSTAR INC. CABLE CONNECTED TITLE SURVEYOR TO NETWORK ROUTER. PHOTOCELL STARBUCKS FULL LIGHTING AND HVAC CONTROLS SIZE DATE DWG NO REV D 1-29-15 S 15-001 B DATA CONCENTRATOR BASIC LOW VOLTAGE WIRE RUNS B MINOR CLARIFICATIONS CG 2/27/15 SCALE DRAWN SHEET A INITIAL DRAWING RELEASE CG 2/11/15 NONE C. GODWIN 1 OF 1 8 7 6 5 4 1 3 2 1 1 IMPORTANT NOTE EXISTING SURVEYOR SYSTEM TO REMAIN. SHOWN FOR REFERENCE ONLY. N 0 N 0 W U) m 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD 1?221002blac1€jpg GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 = RECEIVED May 06 2024 CITY OF EDMONDS C)DEVELOPMENT SERVICES DEPARTMENT 0 r W O Q O U 0 �OQ U) Z L�jz 0 U) z 0 Qoz w C) W O a W 01f00 a- a, w STORE #: 3232 PROJECT #: 03188-076 ISSUE DATE: 04/15/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRS Revision Schedule Rev Date By Description SHEET TITLE: VENSTAR CONTROL DIAGRAMS SCALE: AS SHOWN SHEET NUMBER: E104 New Yuk• MIeM.Or�.Fe • Lna Argales • SeaMe • Hontlul 800mi-a 3 wMwsdtiudmLm DATA H LES A.Irop OF o OR POP AND FLIT' BE AREA. SU LY POV, ._ =TA A 4IEI -,IFS _ATIOP -AN R FINAL LE TIONF TUNTEF1 E CRAFT BAR CASEWOR�DETAIL POS 01-01 scale: 3/4" = V-0" ID EPT,8r c p 2 TL IT ° FOR o Dk F q FUTU BRW 09-01 Scale: 3/4" = T-0" UILl ,FPTAL Al 1mFr1) I, OF :TA E RECEPT. ARMI °FLF E I t :_T iTE.... TOR -2-DATA F iT FL FUTURE E CRAFT BAR CASEWORK DETAIL WRM 08-02 scale: 3/4" = V-0" 6'-10" 4'-4" V-3" 00 1 1 L-_.__J L — — L —j ------V------------------------V__ I I I I I ' I r--------- 0II 110 I I 11 11 I I -------- --JI IL-- ----- -- -71 a" 21" A E" (533MM A TEE Ni, P PENETRATION AREA. ELF LY POWER AN FATA F( CUIT FOR 0 MACHINES, INSTANT F T WATE fiORRSTA6TION AS APPLIC' 1 ON FOR FINAL LOCATION.. LL1aa 1'-5 3/4" X-7 1/4" I Flo] P r 1 —� L----� _R RILL' ESP 11-01 P� FAELF O °- F FOR I DEVICES Fri%Arm PEA- aE PTAF F FOR FUTUi EDGE OF AAFIINFT SHELVI POW[ DA4 �x F F °P CRAFT BAR CASEWORK DETAIL POWERAN _ A (7 11 LIED "1 L OF --- A.F.F. %L 1EPTACLE R LA _L IN I E FUTURE A NDWR CT DEVICES O O °L-DA I . FUTUr VER AN -'' TOF -LE A.F.F. `PTA E >, ONNI I� 2'-0 3/4" 10 0®IQ, I [IoET1-r I1 L___._L_J L_J l `1 9 _1r._ IVY "may II II II II P ' A l F =.F. ° .ATF o E FOR i OT 301LEIT °FFE EF � LE FL" CRAFT BAR CASEWORK DETAIL �r 'OE GENERATOR °EFEPTAC1 F FOR �1 TA ATA N PIN T/41 FUTUR fV 4'-7 3/4" 0,111, IIII�,1� � ;1�171=1��1Tt V-3" 2'-6 1 /2" I 1 il115111]Y 11'-8" ELECTRICAL GENERAL NOTES A. ELECTRICAL CONTRACTOR -COORDINATE WITH PLUMBING AND LOW VOLTAGE TRADES FOR SPACE LAYOUT. ASSURE SPACE FOR WALL MOUNTED EQUIPMENT, PLUMBING AND DATA BOXES ARE WELL PLANNED FOR INSTALL. X-3 1 /2" ` FFIi RAND DATA TALEP AT ELF„ a TO TOP OF E aCLE A.F.F. I. n JB --- U N [ LIG 2'-10 3/4" • T-3 1 /2" T T T T T T I I I I I I I I I T4 I I I I I I I I I I I I I I I I I I I I I I I I I I I I G� DUNTER P.F. __IUNTERRITROGEN L (71E1MM) TO T� PEFEPTAC' RAND DATA PTATLEE AT 83" AM) TO TOF ITE P1ACAE AJ °RE -:PT,' LE F mI NEE ° LE FOR JT�_ - _r1SEP °EE AL LABEL P IE1 °F-DATA F LABEL PRIM A. I .I. Pn FI TTA LT 28" O 0 °EFL LAb, AND' iER _FFT FOR JAIL USE *BLENDER 0 'JTITY BASED IIPI` T CEP RI /_0 Of r A.F.F. 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD I:1221002 - Starbucka Interurban AverruelGdg-Ingo-Mack jpg GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 RECEIVED = May 06 2024 O CITY OF E DEVELOPMENTT SERVICES 0 DEPARTMENT r 06 CD Q 0 S W 0) Cn Q U) ❑ W Q fn z W O Q z 0 ❑ zO �oz O W ` � W � ❑ � / LL aW �/ ( IY ter/ w STORE #: 3232 PROJECT #: 03188-076 ISSUE DATE: 04/15/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRS Revision Schedule Rev Date By Description SHEET TITLE: ELECTRICAL DETAILS 0 N 0 0 W U) scale: 3/4" = V-0" CBE 15-01 scale: 3/4" = V-0" RhI wginems New Ya ,M1,M, 0_h •Lo Agde •Sd •Ho,dd 800-M-OM wwwjdvwdmLm I SCALE: AS SHOWN I SHEET NUMBER: E501 :. VOLTAGE CABLE BUNDLE (DMUSIC SYSTEM © 2022 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 RECEIVED May 06 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT # Revision Schedule Rev Date By Description ELECTRICAL DETAILS SHEET NUMBER: E502 OEk, M, Me EQUIPMENT RACK SCHEDULE UPS IES EQUIPMENT ROUTER NETWORK SWITCH I- ICH I I "TN"I"ROLLER DEVIC' S TITEIE NVR LOW VOLTAGECABLE BUNDLES 0 0 .. .. SECURITY O 2022 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 RECEIVED May 06 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT # Revision Schedule Rev Date By Description ELECTRICAL DETAILS SHEET NUMBER: E503 © 2022 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 RECEIVED May 06 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT # Revision Schedule Rev Date By Description ELECTRICAL DETAILS SHEET NUMBER: E504 EXISTING PANEL "A" FED FROM: DISCONNECT SWITCH MOUNTING: FLUSH MOUNTED VOLTAGE: 208Y/12OV, 3 PHASE, 4 WIRE ENCLOSURE: NEMA 1 BUS MATERIAL: EXISTING FAULT CURRENT: EXISTING BUS LOAD: 379 AMPS AIC/SCCR RATING: MATCH EXISTING BUS RATING: 400 AMPS OPTIONS*: BONDED EQUIPMENT GROUND BAR MAIN: 400/3 MAIN BREAKER LOAD (VA) LOAD (VA) NOTES CKT. LOAD DESCRIPTION A B C BREAKER BREAKER A B C LOAD DESCRIPTION CKT. NOTES 1 RHP-1 5356 80/3 20/1 560 BANQ. SEATING RECEIPT 2 3 ----- 5356 - - - 20/1 840 SEASONAL RECEPT 4 5 ----- 5356 - - - 20/1 840 U/C REFRIG 6 NOTE 3 GFCI 7 NITRO GENERATOR 1000 20/1 20/1 1560 BLENDER 8 NOTE 2 GFCI 9 NITRO DISPENSER 720 20/1 20/1 1560 BLENDER 10 NOTE 1 GFCI 11 DPM TABLET 180 20/1 20/1 1200 REACH IN REFRIG/FREEZER 12 GFCI GFCI 13 ESPRESSO 3300 40/2 20/1 1500 ESP INSTAHOT 14 GFCI 15 3300 - - - 20/1 1400 GRINDER/SCALE 16 GFCI GFCI 17 ESPRESSO 3300 40/2 20/1 SPARE 18 19 3300 - - - 20/1 360 RTU RECEIPT 20 GFCI 21 WARMING OVEN 1000 2984 30/2 20/1 840 U/C REFRIG 22 GFCI 23 ----- 2984 - - - 50/2 4170 DUAL SOFT HEATER BREWER 24 GFCI GFCI 25 DISHWASHER 3300 50/2 - - - 4170 ----- 26 27 3300 - - - 20/1 1200 ICE MACHINE DIVERTER 28 GFCI GFCI 29 WARMING OVEN 2950 30/2 20/1 600 ICE MACHINE EVAP 30 GFCI 31 ----- 2950 - - - 20/1 840 POS 32 GFCI GFCI 33 U/C REFRIG/CUP LABELER 1020 20/1 20/1 900 POS EQUIPMENT 34 GFCI GFCI 35 REACH IN REFRIG/FREEZER 1200 20/1 20/1 200 SAFE 36 GFCI GFCI 37 REACH IN REFRIG/FREEZER 1200 20/1 100/3 3030 SUBFEED PANEL 'C' 38 GFCI 39 FOOD CASE (POS) 1310 20/2 --- 3581 ------ 40 41 ----- 1310 - - - --- 3762 ------ 42 FEED -THROUGH LUGS 22066 FTL SUBFEED PANEL 'B' 23120 FTL 24409 FTL NOTES: * SEE SPECIFICATIONS FOR OTHER OPTIONS REQUIRED BUT NOT NECESSARILY NOTED HERE GFCI PROVIDE GROUND -FAULT CIRCUIT -INTERRUPTER (GFCI) 5 MILLIAMP TRIP TYPE CIRCUIT BREAKER. NOTE 1 RELOCATE EXISTING CIRCUIT FROM A-42 TO A-10 NOTE 2 RELOCATE EXISTING CIRCUIT FROM A-40 TO A-8 NOTE 3 RELOCATE EXISTING CIRCUIT FROM A-38 TO A-6 LOAD ANALYSIS FOR PANEL "A" (INCLUDING SUBFEEDS) LOAD DESCRIPTION DEMAND FACTOR PHASE A (VA) PHASE B (VA) PHASE C (VA) TOTAL (VA) CONNECT. DEMAND CONNECT. DEMAND CONNECT. DEMAND CONNECT. DEMAND LIGHTING: 125% 2018 2523 2569 3212 5285 6606 9872 12340 RECEPTACLE: 83% 6100 5078 6340 5278 2600 2165 15040 12520 OTHER CONTINUOUS: 125% 0 0 100 125 0 0 100 125 OTHER NONCONTINUOUS: 100% 1500 1500 0 0 2000 2000 3500 3500 KITCHEN: 65% 30214 19640 28694 18652 28194 18327 87102 56617 MOTOR: 100% 15612 15612 15712 15712 15212 15212 46536 46536 ADD 25% OF LARGEST MOTOR: 100% 1021 1021 1021 1021 1021 1021 3063 3063 TOTAL: 56465 45373 54436 43998 54312 45329 165212 134700 EQUIVALENT AMPS: 471 379 454 367 453 378 459 374 PHASE BALANCE: 1.05% -2.01% 0.96% EXISTING PANEL "B" FED FROM: PANEL "A" MOUNTING: FLUSH MOUNTED VOLTAGE: 208Y/12OV, 3 PHASE, 4 WIRE ENCLOSURE: NEMA 1 BUS MATERIAL: EXISTING FAULT CURRENT: EXISTING BUS LOAD: 204 AMPS AIC/SCCR RATING: MATCH EXISTING BUS RATING: 400 AMPS OPTIONS*: BONDED EQUIPMENT GROUND BAR MAIN: MAIN LUG ONLY LOAD (VA) LOAD (VA) NOTES CKT. LOAD DESCRIPTION A B C BREAKER BREAKER A B C LOAD DESCRIPTION CKT. NOTES 1 EXHAUST FANS 400 20/1 110/3 9856 RHP-2 2 3 ICE MACHINE 1456 20/2 - - - 9856 ----- 4 5 ----- 1456 - - - - - - 9856 ----- 6 7 SPARE 20/1 20/1 1200 REACH IN REFRIG/FREEZER 8 GFCI GFCI 9 WARMING OVEN 2950 30/2 30/3 2834 OVEN 10 GFCI 11 ----- 2950 - - - - - - 2834 ----- 12 GFCI 13 ESP INSTAHOT 1500 20/1 - - - 2834 ----- 14 GFCI 15 U/C REFRIG 840 20/1 20/1 1200 MANAGERS DESK 16 HPL 17 HAND DRYER 1500 20/1 20/1 500 MANAGERS DESK 18 HPL 19 HAND DRYER 1500 20/1 20/1 1200 MANAGERS DESK 20 GFCI 21 WATER FILLER 500 20/1 20/1 100 LCP 22 GFCI 23 HOT WATER DISPENSER 1300 20/1 20/1 420 EXTERIOR BUILDING LIGHTS 24 GFCI 25 DIGITAL MENUBOARD 360 20/1 20/1 1080 DT ORDER MONITOR/MISC WR 26 GFCI GFCI 27 U/C REFRIG 840 20/1 20/1 1000 DT COMM BASE/CCTV 28 GFCI GFCI 29 CUP LABELERS 360 20/1 20/1 900 DT POS & EXPEDITOR 30 GFCI GFCI 31 REACH IN REFRIG/FREEZER 1200 20/1 20/1 200 DT WINDOW 32 GFCI 33 U/C REFRIG 840 20/1 20/1 1000 DT MENUBOARD/PREMENU 34 35 SITE POLE LIGHTS 1058 20/2 20/1 800 DT ORDER BOARD 36 37 ----- 1058 - - - 20/1 600 DT SIGNAGE 38 39 EXTERIOR SIGNAGE 1200 20/1 20/1 500 P-1 40 C-1 41 EXTERIOR SIGNAGE 1200 20/1 20/1 500 FILTER SYSTEM 42 NOTES: * SEE SPECIFICATIONS FOR OTHER OPTIONS REQUIRED BUT NOT NECESSARILY NOTED HERE GFCI PROVIDE GROUND -FAULT CIRCUIT -INTERRUPTER (GFCI) 5 MILLIAMP TRIP TYPE CIRCUIT BREAKER. HPL PROVIDE PERMANENTLY -INSTALLED HANDLE PADLOCK ACCESSORY TO LOCK CIRCUIT BREAKER IN THE OPEN POSITION. C-# ROUTE CIRCUIT THROUGH CONTACTOR (# = CONTACTOR DESIGNATION). LOAD ANALYSIS FOR PANEL "B" (INCLUDING SUBFEEDS) LOAD DESCRIPTION DEMAND FACTOR PHASE A (VA) PHASE B (VA) PHASE C (VA) TOTAL (VA) CONNECT. DEMAND CONNECT. DEMAND CONNECT. DEMAND CONNECT. DEMAND LIGHTING: 125% 1658 2073 2200 2750 3478 4348 7336 917D RECEPTACLE: 100% 2840 2840 2200 2200 1400 1400 6440 6440 OTHER CONTINUOUS: 125% 1 0 0 100 125 0 0 100 125 OTHER NONCONTINUOUS: 100% 1500 1500 0 0 2000 2000 3500 3500 KITCHEN: 65% 6734 4378 10260 6669 8900 5785 25894 16832 MOTOR: 100% 10256 10256 10356 10356 9856 9856 30468 30468 ADD 25% OF LARGEST MOTOR: 100% 1020 1020 1020 1020 1020 1020 3060 3060 TOTAL: 24008 22066 26136 23120 26654 24409 76798 69595 EQUIVALENT AMPS: 201 184 218 193 223 204 214 194 PHASE BALANCE: V111111,j -4.88% -0.34% 7777775.22% PANEL "C" FED FROM: PANEL "A" VOLTAGE: 208Y/12OV, 3 PHASE, 4 WIRE BUS MATERIAL: ALUMINUM OR COPPER BUS LOAD: 32 AMPS BUS RATING: 100 AMPS MAIN: MAIN LUG ONLY LOAD (VA) MOUNTING: ENCLOSURE: FAULT CURRENT: AIC/SCCR RATING: OPTIONS*: LOAD (VA) FLUSH MOUNTED NEMA 1 7779 AMPS 10 kA BONDED EQUIPMENT GROUND BAR NOTES CKT. LOAD DESCRIPTION A B C BREAKER BREAKER A B C LOAD DESCRIPTION CKT. NOTES GFCI 1 ICE DISPENSER 1200 20/1 20/1 1500 EQUIPMENT RACK 2 GFCI 3 MILK DISPENSER 800 20/1 20/1 1500 EQUIPMENT RACK 4 GFCI 5 RINSER SENSOR/FUTURE USE 560 20/1 20/1 1000 SECURITY 6 C-2 7 CAFE LEFT TRACK 120 20/1 20/1 240 CAFE RIGHT TRACK 8 C-2 C-1 9 WORKROOM LIGHTING 369 20/1 30/2 SPARE 10 C-2 11 CAFE LIGHTING 1807 20/1 - - - ----- 12 13 SPARE 20/1 20/1 SPARE 14 15 SPARE 20/1 20/1 900 CONV RECEIPT 16 17 SPACE ONLY SPACE ONLY 18 19 SPACE ONLY SPACE ONLY 20 21 SPACE ONLY SPACE ONLY 22 23 SPACE ONLY SPACE ONLY 24 25 SPACE ONLY SPACE ONLY 26 27 SPACE ONLY SPACE ONLY 28 29 SPACE ONLY SPACE ONLY 30 NOTES: * GFCI C-# SEE SPECIFICATIONS FOR OTHER OPTIONS REQUIRED BUT NOT NECESSARILY NOTED HERE PROVIDE GROUND -FAULT CIRCUIT -INTERRUPTER (GFCI) 5 MILLIAMP TRIP TYPE CIRCUIT BREAKER. ROUTE CIRCUIT THROUGH CONTACTOR (# = CONTACTOR DESIGNATION). LOAD ANALYSIS FOR PANEL "C" (INCLUDING SUBFEEDS) LOAD DESCRIPTION DEMAND FACTOR PHASE A (VA) PHASE B (VA) PHASE C (VA) TOTAL (VA) CONNECT. DEMAND CONNECT. DEMAND CONNECT. DEMAND CONNECT. DEMAND LIGHTING: 125% 360 450 369 462 1807 2259 2536 3170 RECEPTACLE: 100% 1500 1500 2400 2400 1000 1000 4900 4900 KITCHEN: 90% 1200 1080 800 720 560 504 2560 2304 TOTAL: 3060 3030 3569 3582 3367 3763 9996 10374 EQUIVALENT AMPS: 26 26 30 30 29 32 28 29 PHASE BALANCE: -12.37% 3.57% 8.80% © 2022 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 RECEIVED May 06 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT # Revision Schedule Rev Date By Description SCHEDULES ONE -LINE DIAGRAM SHEET NUMBER: E601 MECHANICAL PLAN NOTES OEXISTING CARRIER 48LCE007A2A, 6 TON ROOFTOP UNIT TO BE REPLACED, RE -USE EXISTING CURB. VERIFY EXACT LOCATION IN THE FIELD. SEE SHEET M501 FOR ROOFTOP UNIT SCHEDULE. INSTALLATION MAY REQUIRE TRANSITION CURB ADAPTOR, RETAIL AIR SYSTEMS, CURSTOM CURB, OR EQUAL MANUFACTURER. OEXISTING ROOF MOUNTED EXHAUST FAN TO REMAIN. CONTRACTOR SHALL BALANCE EXISTING FAN TO ALLOW 200 CFM OF EXHASUT AIR. FIELD VERIFY EXACT LOCATION. O3 EXISTING EXHAUST AIR DUCTWORK UP TO EXISTING EF-1 ON ROOF TO REMAIN. OEXISTING EXHAUST AIR GRILLE TO REMAIN. CONTRACTOR SHALL CLEAN AND REPAIR GRILLE TO A LIKE NEW CONDITION. IF THE DEVICE CANNOT BE REPAIRED TO A LIKE NEW CONDITION, IT SHALL BE REPLACED WITH A NEW GRILLE THAT MATCHES THE EXISTING DEVICE IN EVERY RESPECT. OUNDERCUT DOOR 3/4" TO ALLOW TRANSFER OF AIR. OPROVIDE TEMPORARY CONSTRUCTION THERMOSTAT. MOUNT (2) THERMOSTATS AT 48" ABOVE FINISHED FLOOR. THERMOSTAT SHALL BE CAPABLE OF PREVENTING THE SUPPLEMENTARY ELECTRIC HEAT FROM OPERATING WHEN THE HEATPUMP CAN MEET THE HEATING LOAD. COORDINATE LOCATION WITH CONSTRUCTION MANAGER. FINAL EMS THERMOSTAT PROVIDED BY VENSTAR. MOUNT VENSTAR REMOTE TEMPERATURE SENSOR AT 60" AFF. ODUCT SMOKE DETECTOR ON RETURN SIDE DUCT AND SHUTDOWN RELAY SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR FOR INSTALLATION BY THE MECHANICAL CONTRACTOR. ALL WIRING SHALL BE BY THE ELECTRICAL CONTRACTOR. O$ EXISTING ROOF MOUNTED EXHAUST FAN, FLAT ROOF CURB, AND ASSOCIATED DUCTWORK TO BE REMOVED. REFER TO ARCHITECTURAL SHEETS FOR ROOF REPAIR REQUIREMENTS. N MECHANICAL GENERAL NOTES A. EXISTING CONDITIONS ARE BASED ON RECORD DRAWINGS PROVIDED BY THE OWNER. CONTRACTOR SHALL ADJUST TO ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE PROJECT. B. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE GOVERNMENT AND LOCAL CODES. C. MECHANICAL CONTRACTOR SHALL FIELD COORDINATE WITH ELECTRICAL CONTRACTOR FOR ALL POWER REQUIREMENTS. D. THE CONTRACTOR SHALL COOPERATE WITH THE OTHER TRADES SO THAT THE INSTALLATION OF ALL EQUIPMENT MAY BE PROPERLY COORDINATED. E. ALL EQUIPMENT FURNISHED SHALL FIT THE SPACE AVAILABLE WITH CONNECTIONS IN THE REQUIRED LOCATIONS AND WITH ADEQUATE SPACE FOR OPERATING AND SERVICING. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND INDICATE THE INTENT OF THE INSTALLATION WHILE THE SPECIFICATIONS AND EQUIPMENT LIST DENOTE THE TYPE AND QUALITY OF MATERIAL AND WORKMANSHIP TO BE USED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENTS. WHERE A CONFLICT EXISTS BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE HIGHER AND/OR MORE COSTLY STANDARD WILL APPLY. THE CONTRACTOR SHALL PROMPTLY NOTIFY THE ENGINEER WHOSE DECISION SHALL BE FINAL. NO ALLOWANCE WILL BE MADE SUBSEQUENTLY IN THIS REGARD ON BEHALF OF THE CONTRACTOR AFTER AWARD OF THE CONTRACT. F. COORDINATE DUCT ROUTING AND HEIGHTS WITH GENERAL CONTRACTOR. VERIFY ALL CLEARANCES BEFORE STARTING WORK. G. THE CONTRACTOR SHALL INSTALL ALL PIPING, DUCTWORK AND EQUIPMENT AS REQUIRED TO CONFORM TO THE STRUCTURE, AVOID OBSTRUCTIONS, PRESERVE CEILING HEIGHTS AND HEADROOM AND MAKE ALL EQUIPMENT REQUIRING MAINTENANCE OR REPAIR ACCESSIBLE. H. ALL DUCT CONNECTIONS TO HVAC EQUIPMENT MUST BE MADE WITH FLEXIBLE CONNECTORS. I. DO NOT ATTACH ANYTHING TO DECK ABOVE. ATTACH TO STRUCTURE (i.e. BEAMS, JOISTS) ONLY. DUCT HANGERS SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODE. ALL CONNECTIONS TO JOISTS SHALL BE MADE AT THE TOP CORD. J. ALL DUCT DIMENSIONS INDICATED ARE CLEAR INSIDE DIMENSIONS. ALL SUPPLY AND UNTEMPERED OUTDOOR AIR DUCTWORK SHALL BE LINED WITH 1"ACOUSTICAL DUCT LINER OR WRAPPED WITH 1-1/2" THICK FIRE RETARDANT FIBERGLASS WITH A REINFORCED ALUMINUM FOIL JACKET AND SHALL BE APPROVED FOR USE BY SMACNA AND NAIMA. RETURN AIR TRANSFER DUCTS AND RETURN DUCTWORK WITHIN 10 FEET OF THE UNIT FAN SHALL BE LINED WITH 1" ACOUSTICAL DUCT LINER. K. ALL SUPPLY AND UNTEMPERED OUTDOOR AIR DUCTWORK VISIBLE TO THE PUBLIC SHALL BE INTERNALLY LINED AND PAINTED TO MATCH THE SURROUNDING AREA. DUCT WRAP INSULATION IS NOT PERMITTED IN THESE AREAS. L. TENANT'S CONTRACTOR SHALL BE RESPONSIBLE FOR THE FIELD VERIFICATION OF ALL UTILITY RUNS AND/OR OTHER IMPROVEMENTS LOCATED ON THE PREMISES PRIOR TO BIDDING. TENANT'S CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR ALL COSTS RELATING TO THE RELOCATION OF, DAMAGE TO, REPAIR OF ANY EXISTING UTILITY RUNS AND/OR IMPROVEMENTS WHICH ARE DAMAGED AS A RESULT OF TENANT'S WORK IN OR AROUND THE PREMISES. M. ALL ROOFING WORK SHALL BE PERFORMED BY LANDLORD'S APPROVED ROOFING CONTRACTOR AT TENANT'S EXPENSE, IF REQUIRED IN LEASE OR TENANT CRITERIA MANUAL. N. MECHANICAL CONTRACTOR SHALL PROVIDE TENANT WITH A WRITTEN ONE (1) YEAR MANUFACTURER'S WARRANTY ON ALL HVAC EQUIPMENT PROVIDED AND / OR INSTALLED. THE WARRANTY SHALL INCLUDE ALL LABOR, MATERIALS AND THREE (3) ROUTINE SERVICES INCLUDING FILTER CHANGES DURING A ONE (1) YEAR PERIOD. O. AT THE COMPLETION OF CONSTRUCTION AN NEBB, AABC OR TABB CERTIFIED AIR BALANCE REPORT SHALL BE SUBMITTED TO THE ENGINEER AND LANDLORD. THE BALANCING MUST BE COMPLETED BY AN INDEPENDENT, THIRD PARTY CONTRACTOR WITH NO TIES TO THE INSTALLING CONTRACTORS. P. ALL THERMOSTATS, SENSORS, AND ASSOCIATED CONTROLS SHALL BE COORDINATED WITH VENSTAR. � 5 khnxkelevinmme N.. a ..h..L.A�d..—.H.—I ,� wwmadmdaLm m 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2021.10.22 ARCHITECT OF RECORD 1:1221002 - Starbucks Interurban AvenuelGdg-Ingo-blackjK GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 = RECEIVED May 06 2024 CITY OF EDMONDS C)DEVELOPMENT SERVICES DEPARTMENT O V_ 06 C) 04 Q W VT) r/ w Z L�jQ C % Q VJ Z O Q o z wLu � C) LU a W a- a, w STORE #: 3232 PROJECT #: 03188-076 ISSUE DATE: 04/15/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRS Revision Schedule Rev Date By Description SHEET TITLE: MECHANICAL DESIGN PLAN SCALE: AS SHOWN SHEET NUMBER: M101 ROOF TOP HEAT PUMP UNITS COOLING HEATING SUPPLY EXT. ELECTRICAL COOL AT ELEC FAN TRANE MARK AIR S.P. WEIGHT SEER HSPF REMARKS BHP MODEL NUMBER 7ENTOT (MBH) (TON) (KW) (CFM) (IN) VOLT PH MCA MOCP (LBS) /EER /COP (MBH) RHP-1 97.0 118.1 10 102.2 13.5 1 4,000 1 0.60 1.38 208 3 54 80 1 1,053 -/11.0 -/3.41 WSC120H3 (1-10,12) RHP-2 1 97.0 118.1 10 1 102.2 13.5 1 4,000 1 0.60 11.38T208 1 3 1 101 110 1 1,053 -/11.0 - /3.41 WSC120H3 (1-12) TRANE IS THE BASIS OF DESIGN, HIGH EFFICIENCY CARRIER, LENNOX, AAON OR YORK ARE EQUAL. COOLING CAPACITIES ARE BASED ON AHRI STANDARD 210/240 OR 340/360: 807 DB/ 677 WB INDOOR ENTERING AIR TEMPERATURE, 95°F DB AIR ENTERING OUTDOOR FAN. SCHEDULED UNIT MAY DIFFER FROM AHRI STANDARD CFM. REMARKS: 1. PROVIDE EQUIPMENT WITH SCCR GREATER THAN THE AVAILABLE FAULT CURRENT AT THE EQUIPMENT OR UPSTREAM PANELBOARD. REFER TO THE ELECTRICAL ONE LINE DIAGRAM AND PANEL SCHEDULES FOR AVAILABLE FAULT CURRENT AT UPSTREAM PANELBOARD. 2. PROVIDE WITH FACTORY INSTALLED DISCONNECT, UNPOWERED CONVENIENCE OUTLET, THROUGH THE BASE ELECTRICAL CONNECTION. 3. PROVIDE WITH DRY BULB ECONOMIZER AND BAROMETRIC RELIEF DAMPER. 4. ECONOMIZER SHALL INCLUDE FAULT DETECTION DIAGNOSTICS (FDD). DAMPER LEAKAGE SHALL MEET APPLICABLE ENERGY CODE. 5. PROVIDE WITH CONDENSER COIL HAIL GUARD. 6. DUCT SMOKE DETECTOR ON THE RETURN SIDE DUCT AND SHUTDOWN RELAY SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR FOR INSTALLATION BY THE MECHANICAL CONTRACTOR. ALL WIRING SHALL BE BY THE ELECTRICAL CONTRACTOR. 7. PROVIDE CORROSION PROTECTION - PHENOLIC EPDXY COATING, FACTORY APPLIED TO CONDENSER AND EVAPORATOR COILS. 8. PROVIDE WATER LEVEL MONITORING DEVICE IN DRAIN PAN TO SHUT OFF UNIT IF THE DRAIN LINE BECOMES RESTRICTED. 9. UNITS WITH COOLING CAPACITY GREATER THAN OR EQUAL TO 65 MBH SHALL HAVE MULTI -STAGE CAPABILITY PER APPLICABLE ENERGY CODE. 10. PROVIDE ADAPTOR CURB. 11. PROVIDE WITH MODEL BAYHTRA318 SUPPLEMENTAL HEATER, 18.0 KW AT 240 VOLT, 13.5 KW AT 208 VOLT, 3 PHASE ELECTRIC HEATER. 12. PROVIDE CONTROLS TO PREVENT THE SUPPLEMENTARY ELECTRIC HEAT FROM OPERATING WHEN THE HEAT PUMP CAN MEET THE HEATING LOAD. DIFFUSERS, GRILLES AND REGISTERS MARK SERVICE LOCATION CEILING TYPE MOUNTING TYPE MANUFACTURER MODEL NUMBER REMARKS D-1 SUPPLY CEILING AC TILE LAY -IN TITUS OMNI X 3 24x24 26 D-75 1,2,5 D-2 SUPPLY CEILING GYP. BOARD LAY -IN TITUS OMNI X 3 12x12 26 D-75 (1,2,4,5) D-3 SUPPLY CEILING AC TILE LAY -IN TITUS FTI-10-2-4-12-66-HT 1,2,5 D-4 SUPPLY CEILING GYP. BOARD SURFACE TITUS FL-10-2-77-HT/FBPI-10-2-10 (1,2,5) D-5 SUPPLY DUCT NA SURFACE TITUS 30ORL-XX-1-26 1,2,5 G-1 IRETURN/TRANS1 CEILING AC TILE LAY -IN TITUS 50F X X X 3 26 (1-3,5 G-2 I RETURN CEILING GYP. BOARD SURFACE TITUS 50F X X X 1 26 1-3,5) REMARKS: 1. TITUS IS THE BASE OF DESIGN. KRUEGER, PRICE, NAILOR, CARNES ARE 2. SEE PLAN FOR NECK SIZE. 3. PROVIDE 1 /2" X 1 /2" X 1" CORE. 4. PROVIDE WITH MODEL TRM FRAME. 5. COORDINATE WITH ARCHITECT AND STARBUCKS CONSTRUCTION MANAGER EQUAL. NO EXCEPTIONS. ON FINAL FINISH AND COLOR FOR ALL AIR DEVICES. DIA. WIRE DIA. ROD STRAP 10" DN ONE 12 GA. 1/4" 1" x 22 GA. 11-18" TWO 12 GA. OR ONE 8 GA. 1 /4" 1 " x 22 GA. 19-24" TWO 10 GA. 1/4" 1" x 22 GA. 25-36" TWO 8 GA. 3/8" 1" x 20 GA. 37-50" - TWO 3/8" TWO 1 " x 20 GA. 51-60" - TWO 3/8" TWO 1 " x 18 GA. 61-84" - TWO 3/8" TWO 1 " x 16 GA. 85-96" - TWO 1 /2" TWO 1 1 /2" x 16 GA. NOTES: 1. STRAPS ARE GALVANIZED STEEL; RODS ARE UNCOATED OR GALVANIZED STEEL; WIRE IS BLACK ANNEALED, BRIGHT BASIC OR GALVANIZED STEEL. ALL ARE ALTERNATIVES. 2. TABLE ALLOWS FOR CONVENTIONAL WALL THICKNESS, AND JOINT SYSTEMS PLUS ONE LB/SF OF INSULATION WEIGHT. IF HEAVIER DUCTS ARE TO BE INSTALLED, ADJUST HANGER SIZES TO BE WITHIN THEIR LOAD LIMITS. HEATING VENTILATING AND AIR CONDITIONING SYMBOLS SYMBOL DESCRIPTION SYMBOL DESCRIPTION THERMOSTAT WITH CONTROL WIRING {}VD MANUAL VOLUME DAMPER {}MD MOTORIZED DAMPER Q HUMIDISTAT (BY EQUIPMENT MANUFACTURER) {RFD FIRE DAMPER ROUND DUCT RISER OR DROP {LSD SMOKE DAMPER ® SUPPLY OR OUTDOOR AIR DUCT RISER OR DROP (SA OR OA) {=F-FD.SD COMBINATION FIRE AND SMOKE DAMPER 400 CFM 10 0 D X SQUARE/RECTANGULAR DIFFUSER WITH AIRFLOW TAG. SEE SCHEDULE FOR EXACT DIFFUSER TYPE. PROVIDE SECTORIZING BAFFLES TO ACHIEVE AIRFLOW PATTERN SHOWN. RETURN OR EXHAUST AIR DUCT RISER OR DROP (RA OR EA) 10 6 RECTANGULAR DUCT WITH SIZE FIRST FIGURE IS SIDE SHOWN '00 CFM 10""0 D-X ROUND DIFFUSER WITH AIRFLOW TAG SEE SCHEDULE FOR EXACT DIFFUSER TYPE 1010 ROUND DUCT WITH SIZE �-- �10'op e lJ_11111 FLEXIBLE DUCT WITH SIZE ELBOW WITH TURNING VANES T 400 CFM 1216 D- SQUARE/RECTANGULAR SUPPLY GRILLE WITH AIRFLOW TAG. SEE SCHEDULE FOR EXACT DIFFUSER TYPE. ADJUST BLADES OR PATTERN CONTROLLER TO ACHIEVE AIRFLOW PATTERN SHOWN. EXISTING NEW WORK POINT OF CONNECTION BETWEEN NEW AND EXISTING WORK. 100 CFM 616 G-X EXHAUST AIR GRILLE WITH AIRFLOW TAG SEE SCHEDULE FOR EXACT GRILLE TYPE 1,200 CFM oA�, MINIMUM OUTDOOR AIR 6 6 G-X RETURN AIR GRILLE WITH TAG SEE SCHEDULE FOR EXACT GRILLE TYPE DUCT SMOKE DETECTOR HATCH PATTERN INDICATES ITEMS BEING REMOVED. NOTE: NOT EVERY DEVICE OR SYMBOL IN THIS LEGEND MAY BE USED ON THIS PROJECT. HEATING VENTILATING AND AIR CONDITIONING ABBREVIATIONS ABBREVIATION TERM ABBREVIATION TERM AFF ABOVE FINISHED FLOOR MBH 1000 BTU PER HOUR CFM CUBIC FEET PER MINUTE FA OR CA OUTDOOR AIR EA EXHAUST AIR RA RETURN AIR HVAC HEATING VENTILATING AND AIR CONDITIONING SA SUPPLY AIR © 2022 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 RECEIVED May 06 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT # Revision Schedule Rev Date By Description MECHANICAL DETAILS SHEET NUMBER: M501 DUCT SHOULD EXTEND STRAIGHT MAXIMUM PAIR AT PAIR AT PAIR AT PAIR AT FOR SEVERAL INCHES FROM A HALF OF 10 FT. SPACING 8 FT. SPACING 5 FT. SPACING 4 FT. SPACING CONNECTION BEFORE BENDING DUCT WIRE/ WIRE/ WIRE/ WIRE/ PERIMETER STRAP ROD STRAP ROD STRAP ROD STRAP ROD r,► 1 1/2" (38mm) MINIMUM 2 = 30" 1" x 22 GA. ( 135") 1" x 22 GA. 10 GA. � 135") 1" x 22 GA. A. 106A� 1" x 22 GA. � 106A� - • CiM P = 72" 1 " x 18 GA. 3/8" 1 " x 20 GA. 1 /4" 1 " x 22 GA. 1 /4" 1 " x 22 GA. 1 /4" 2 0 P = 2 96" 1 " x 16 GA. 3/8" 1 " x 18 GA. 3/8" 1 " x 20 GA. 3/8" 1 " x 22 GA. 1 /4" © 2022 STARBUCKS COFFEE COMPANY MAX. SAG 1/2" PER / 1 1 „ (38mm) BAND CLAMP P STARBUCKS ( ) FOOT 41.7 mm PER m �/2 , WITH WIRE /S OPTIONAL — = 120 1 1/2 x 16 GA. 1/2 1' x 16 GA. 3/8 1 x 18 GA. 3/8' 1" x 20 GA. 1/4' OF SUPPORT SPACING 2 2401 UTAH AVENUE SOUTH P SEATTLE, WASHINGTON 98134 2 = 168" 1 1 /2" x 16 GA. 1 /2" 1 1 /2" x 16 GA. 1 /2" 1 " x 16 GA. 3/8" 1 " x 18 GA. 3/8" (206) 318-1575 A`p„T�2pp P = 192" --- 1/2" 1 1/2" x 16 GA. 1/2" 1" x 16 GA. 3/8" 1" x 16 GA. 3/8" THESE DRAWINGS AND THE PROJECT MANUAL himJM 2 ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS '�I'7MOij,, IRE P CORPORATION, WHICH IS THE OWNER OF THE MAX. SAG 1/2" PER 2 193" UP SPECIAL ANALYSIS REQUIRED = COPYRIGHT IN THIS WORK. THEY SHALL NOT FOOT (47.7 mm PER m) BE REPRODUCED (IN WHOLE OR IN PART), OF SUPPORT SPACING WHEN STRAPS ARE LAP JOINED SINGLE HANGER MAXIMUM ALLOWABLE LOAD SHARED WITH THIRD PARTIES OR USED IN ANY L- USE THESE MINIMUM FASTENERS: MANNER ON OTHER PROJECTS OR STRAP WIRE OR ROD (DIA.) EXTENSIONS TO THIS PROJECT WITHOUT THE 1 " x 18, 20, 22 GA. — TWO #10 OR ONE 1 /4" BOLT PRIOR WRITTEN CONSENT OF STARBUCKS �<--1 1/2" (38mm) MINIMUM 1" x 16 GA. — TWO 1/4" DIA. 1" x 22 GA. —260 LBS. 0.106" — 80 LBS. CORPORATION. THESE DRAWINGS AND 1" x 20 GA. — 320 LBS. 0.135" — 120 LBS. SPECIFICATIONS ARE INTENDED TO EXPRESS 1 " x 16 GA. — TWO 3/8" DIA. DESIGN INTENT FOR A PROTOTYPICAL CLOSER MAXIMUM INTERVALS MAY BE SPECIFIED PLACE FASTENERS IN SERIES, NOT SIDE BY SIDE. 1 x 18 GA. — 420 LBS. 0.162' — 160 LBS. STARBUCKS STORE (WHICH IS SUBJECT TO AS A CONDITION OF U.L. LISTING, PARTICULARLY / 1 " x 16 GA. — 700 LBS. 1 /4" — 270 LBS. IN FIRE RATED FLOOR — CEILING ASSEMBLIES / 1 1 /2" x 16 GA. — 1100 LBS. 3/8" — 680 LBS. CHANGE AT ANYTIME) AND DO NOT REFLECT f ACTUAL SITE CONDITIONS. NEITHER PARTY 1/2" — 1250 LBS. SHALL HAVE ANY OBLIGATION NOR LIABILITY TO 5/8" — 2000 LBS. THE OTHER (EXCEPT STATED ABOVE) UNTIL A 3/4" — 3000 LBS. WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. NOTES: 1. DIMENSIONS OTHER THAN GAUGE ARE IN INCHES. STARBUCKS TEMPLATE VERSION: i2021.10.22 2. TABLES ALLOW FOR DUCT WEIGHT, 1 LB./SF INSULATION WEIGHT AND NORMAL REINFORCEMENT IBLE DUCT S U PP 0R TS AND TRAPEZE WEIGHT, BUT NO EXTERNAL LOADS. ARCHITECT OF RECORD 3. STRAPS ARE GALVANIZED STEEL; OTHER MATERIALS ARE UNCOATED STEEL. &LLEX 4. ALLOWABLE LOADS FOR P/2 ASSUME THAT DUCTS ARE 16 GA. MAXIMUM, EXCEPT THAT WHEN NOT TO SCALE MAXIMUM DUCT DIMENSION (W) IS OVER 60" THEN P/2 MAXIMUM IS 1.25 W. 1:122100 logoblack;,g 5. 12, 10 OR 8 GA. WIRE IS STEEL OF BLACK ANNEALED, BRIGHT BASIC OR GALVANIZED TYPE. 6. DUCTS SHALL BE SUPPORTED AT INTERVALS NOT EXCEEDING 10 FEET. 25-1/4", 21-1/4", 19-1/4" OR 01 GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 13-1/4" OUTSIDE DIMENSION 1807 7TH AVENUE, SUITE 700 "C" CHANNEL SEATTLE, WA 98101 REINFORCING (206) 224-3335 BY G. C. AROUND OPENING y ROY SC CINCH BAND RECTANGULAR DUCT HANGER TABLE �(O03' ov SIVY/4cti�L9c� 2 (-D� MOUNTING SCREW NOT TO SCALE I— INSULA TED FIELD INSTALLED 315,48 SHEET 23 , 19 ", 17" OR 11 " O F F T�� INSULA TED METAL INSIDE DIMENSION , FLEXIBLE PLENUM d DUCT I DRYWALL CEILING Dote: 04115124 1 1-1/2" a 2609 METAL B STUD O MAX. 45' DIVERGING, 60` CONVERGING 0 MAX. 45° DIVERGING, 60' CONVERGING ROUND TO FRAMING A 15' OR LESS A� B — _ AIR RECEIVED MOUNTING OVAL TRANSITION LO A� — � � STEEL FLOW LB 1-May 06 2024 CITY OF EDMONDS LINEAR 24', 20', 18" OR 12" 1-1/8" FRAME C)DEVELOPMENT SERVICES DIFFUSER W/TH TRANSFORMATION EXPANSION CONTRACTION DEPARTMENT G YP. BD. CEILING CONCEALED C)NOTE FASTENER 1. CONTACT MANUFACTURER FOR INFORMA TION REGARDING ROUGH —IN SIZES. 06 TURNING � � CDTYPICAL DRYWALL VANE r Q Qo LINEAR DIFFUSER DETAIL MOUNTING FRAME DETAIL VANESG oX m 7 4 NOT TO SCALE NOT TO SCALE 2/`30 D rn 0 >Q THREE v J V) Z 90 ELBOW TURNING VANES 2/3D �D� LLI � � Q � RECTANGULAR OR AT ELBOW SIMILAR NO THROAT RADIUS SHORT RADIUS FULL RADIUS z Z C) 0 ROUND OPPOSED O Q Z BLADE DAMPER U U w O 3 1/2" ` W W CINCH BAND o p Q o C:) 0 W a- � W O SLOPE — ° FLEXIBLE CASING 1 � � 1 " IN 7" MAX. 7/8" THREADED CAP, ( INSULATED SLOPE — STORE #: 3232 AND WIRE 50 —O I" /N 7" MAX. 1 /N 4 MIN. TAMPER PROOF OPTIONAL SHEET PROJECT #: 03188-076 MAXIMUM) _ INSULA TED METAL I" IN 4 " M/N. PLAN-- FLEXIBLE ISSUE DATE: 04/15/2024 PLENUM DUCT SUPPLY OR RETURN WYE TURNING VANES DESIGN MANAGER: GRAPHITE METAL RECTANGULAR DUCT o PRODUCTION DESIGNER: GRAPHITE FLEXIBLE CASING AND. STUD O�xO CHECKED BY: GRS WIRE (50 =0" MAXIMUM) ROUND TO O W Revision Schedule MOUNTING BRACKET OVAL TRANSITIONEkf 'N A Rev Date By Description • r^ LINEAR �— DIFFUSER W1 TV L= W 4, 4" MIN. CF"�` ����l G RACK 8c PINION GYP. BD. CEILING / COVER PLATE OPERA TOR CONCEALED FT FASTENER MOUNTING BRACKET 45 DEGREE ENTRY O 45' 90• ELBOW TAKE -OFF ELEVATION COVER PLATE BRANCH TAKE -OFF USE ONLY IN AREAS FULL RADIUS ELBOW SHEET TITLE: SOCKET WRENCH FITTING WHERE SPACE IS LIMITED TAKE -OFF MECHANICAL DETAILS LINEAR SLOT!C1REMOTE VOLUME DAMPER CONTROLLER SERDETAIL DUCTWORK DETAILS SCALE: AS SHOWN 6(j)�I�FFU1 � l SHEET NUMBER: NOT TO SCALE NOT TO SCALE NOT TO SCALE M601 New Yuk• MIeM On®Fe Lna Argales SeaMe Hontlul © 2022 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 RECEIVED May 06 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT # Revision Schedule Rev Date By Description MECHANICAL DETAILS SHEET NUMBER: M701 PLUMBING FIXTURE SCHEDULE - "P" DESIGN IDI COUNT I DESCRIPTION FURN. BY I INST. BY COMMENTS DRAIN 10294 1 7 IDRAIN - FLOOR SINK SQUARE - 51N 125MM ISB jGC 10726 1 8 IDRAIN - GRATE HALF SQUARE - 121N 305MM ISB jGC FAUCET 10152 1 FAUCET - DOUBLE LABORATORY WITH BENT RISER SPOUT SB GC 10153 4 FAUCET - WATER TOWER - 121N 305MM SB GC 10215 2 FAUCET - DOUBLE LABORATORY WITH SWING SPOUT SB GC 10597 2 FAUCET - SINGLE HANDLE SB GC 11003 2 FAUCET - METERED SB GC 22642 3 FAUCET - INSTANTHOT SYSTEM 2 BUTTON WITH BOILER AND BRACKET SB GC KIT INCLUDES FONT, UNDERCOUNTER BOILER AND BOILER BRACKET FOR SIDE PANEL MOUNTING. BRACKET CAN BE FLOOR MOUNTED USING SET OF (4) STAINLESS STEEL LEGS, ORDERED SEPARATELY THROUGH VENDOR. FILTER 23355 1 1 IFILTER - FILTRATION BOOSTER PUMP jSB jGC OTHER 21669 1 1 IGREASE INTERCEPTOR GB75 jGC jGC SINK 10549 1 SINK - RINSE DROP IN SST - 12X201N 305X510MM SB GC 17565 1 SINK - RINSE WITH DRAINBOARD - 15X271N 380X685MM SB GC 18743 1 SINK - WATER FILLING STATION - 36X241N 915X610MM SB GC 22768 1 2 SINK - COUNTERTOP RINSER WITH WATER TOWER - 26X91N 660X235MM SB GC © 2022 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 RECEIVED May 06 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT # Revision Schedule Rev Date By Description PLUMBING SCHEDULES SHEET NUMBER: Pi 00 N PLUMBING SUPPLY PLAN scale: 1 /4" = 1'-0" GENERAL NOTES: A. FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. B. PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. C. ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS. D. REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS OTHERWISE NOTED. E. COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL PLUMBING EQUIPMENT. F. DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. G. REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK. H. COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2" (10MM) THICK SELF SEALING, SECTIONAL CLOSED —CELL FOAM INSULATION. REFER TO SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS. I. CONTRACTOR SHALL CONTACT WATER FILTER SUPPLIER BEFORE THE TIME THAT THE FILTER SYSTEM IS TO BE STARTED UP. J. VERIFY PROPER WATER SYSTEM WITH WATER TEST RESULTS. K. ALL PLUMBING CLEANOUT CANNOT BE COVERED. PLUMBING CLEANOUT MUST HAVE EASY ACCESSIBILITY. L. PROVIDE ACCESS PANELS FOR ELECTRICAL, PLUMBING AND HVAC AS SPECIFIED BY CODE OR AS DICTATED BY THE LANDLORD. KEYED NOTES: OTHIS SPACE IS RESERVED FOR ELECTRICAL EQUIPMENT. NO PIPING SHALL PASS BELOW, ABOVE, OR AROUND ELECTRICAL EQUIPMENT. PROVIDE CODE REQUIRED MINIMUM CLEARANCE ABOVE ELECTRICAL EQUIPMENT ACCESS SPACE. O2 FIXTURE IS EXISTING TO REMAIN. CONTRACTOR TO REVIEW AND BRING TO LIKE NEW CONDITION. REPLACE AS REQUIRED. O3 1/2" CWF TO COFFEE BREWER. INSTALL SHUT—OFF IN CABINET AT 24" AFF. REDUCE TO 3/8- AT UNIT. O4 1/2" CW AND 1/2" HW TO LAB SINK. Q 3/4" CW TO DIPPER WELL. O 3/8" CWF TO WATER TOWER FAUCET LOCATED IN WATER STATION. O 3/8" CWF TO HOT WATER TAP. REDUCE TO 1 /4n AT UNIT. O 1/2" CW TO SINGLE LAB FAUCET. O1/2" CW AND 1/2" HW TO SINK. PROVIDE THERMOSTATIC MIXING VALVE (WATTS LFMMV) IN ACCESS PANEL TO LIMIT TEMPERATURE TO 110` F. 10 1/2" CWF TO ICE MACHINE. REDUCE TO 3/8" AT EQUIPMENT CONNECTION. 11 3/4"CW & 3/4" CWF TO PENETRATE TO BELOW GRADE. ROUTE K—TYPE COPPER PIPING BELOW GRADE TO PENETRATE UP BELOW SINK FIXTURE. 12 1/2" CW & CFW TO COMBI OVEN. INSTALL SHUT—OFF IN CABINET AT 18" AFF UNDER CABINET. PROVIDE BACFKLOW PREVENTER. 13 ROUTE 3" PVC FROM ICE DIVERTER AT ICE MACHINE TO OVERHEAD ICE DISPENSER 14 CONNECT TO EXISTING CW, CS, HW, HWR, AND CFW SYSTEM OF EQUAL OR GREATER SIZE, VERIFY IN FIELD FOR EXACT SIZE AND LOCATION. MAKE ADJUSTMENTS AS NECESSARY. LEGEND EXISTING NEW WORK ® NEW TO EXISTING CONNECTION m 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD b\221D02 — StsrSucks Interurban Avsnua\Gdg---1,jg—bkIsl[4pg GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 = RECEIVED May 06 2024 CITY OF EDMONDS O DEVELOPMENT SERVICES DEPARTMENT O V_ 06 O 04 Q O/�� KT/ V ) v / v, w Z L�jQ 2zIt Q Q 0 50(l z0 <oz w w a W 01�00 a- a, w STORE #: 3232 PROJECT #: 03188-076 ISSUE DATE: 04/15/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRS Revision Schedule Rev Date By Description SHEET TITLE: PLUMBING SUPPLY PLAN SCALE: AS SHOWN SHEET NUMBER: P101 New—MIeM On®Fe•Las AgC •SHtltle•H.—I 800mi-a 3 wMwsdtiudmLm N PLUMBING WASTE & VENT PLAN scale: 1 /4" = 1'-0" GENERAL NOTES: A. FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. B. PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. C. ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS. D. REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS OTHERWISE NOTED. E. COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL PLUMBING EQUIPMENT. F. DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. G. REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK. H. COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2" (10MM) THICK SELF SEALING, SECTIONAL CLOSED -CELL FOAM INSULATION. REFER TO SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS. I. CONTRACTOR SHALL CONTACT WATER FILTER SUPPLIER BEFORE THE TIME THAT THE FILTER SYSTEM IS TO BE STARTED UP. J. VERIFY PROPER WATER SYSTEM WITH WATER TEST RESULTS. K. ALL PLUMBING CLEANOUT CANNOT BE COVERED. PLUMBING CLEANOUT MUST HAVE EASY ACCESSIBILITY. L. PROVIDE ACCESS PANELS FOR ELECTRICAL, PLUMBING AND HVAC AS SPECIFIED BY CODE OR AS DICTATED BY THE LANDLORD. KEYED NOTES: OTHIS SPACE IS RESERVED FOR ELECTRICAL EQUIPMENT. NO PIPING SHALL PASS BELOW, ABOVE, OR AROUND ELECTRICAL EQUIPMENT. PROVIDE CODE REQUIRED MINIMUM CLEARANCE ABOVE ELECTRICAL EQUIPMENT ACCESS SPACE. O 2-WASTE DOWN, 1 1/2" VENT UP. O3 ALL PLUMBING FIXTURES IN THIS HATCHED AREA ARE EXISTING TO REMAIN. O 1 1/2" INDIRECT DRAIN FROM BACK PORTION OF SINK TO FLOOR SINK. O 1" INDIRECT INSULATED DRAIN FROM ICE BIN TO FLOOR SINK. O 3/4" INDIRECT DRAIN FROM ESPRESSO/COFFEE MACHINE TO FLOOR SINK. O7 1" INDIRECT DRAIN FROM UTENSIL RINSE SINK TO FLOOR SINK. Og 1" INDIRECT DRAIN FROM IN -COUNTER RINSER TO FLOOR SINK. Og 1" INDIRECT DRAIN FROM DRIP TRAY TO FLOOR SINK. 10 1" INDIRECT DRAIN FROM ICE MACHINE TO FLOOR SINK. 11 1" INDIRECT DRAIN FROM COMBI OVEN TO FLOOR SINK. 12 CONNECT TO EXISTING VENT SYSTEM OF EQUAL OR GREATER SIZE. EXISTING VENT TERMINATES THROUGH ROOF. 13 CONNECT TO EXISTING SANITARY SEWER LINE OF EQUAL OR GREATER SIZE. VERIFY IN FIELD FOR EXACT LOCATION, SIZE, AND INVERT. 14 REUSE EXISTING SANITARY AND ROUTE TO NEW GREASE WASTE SYSTEM AS SHOWN. PROVIDE NEW GREASE INTERPCEPTOR, SCHIER GB-75, PROVIDE EXTENTIONS AS NEEDED TO MEET FINSHED FLOOR ELELVATION. INSTALL PER MANUFACTURER AND LOCAL AHJ REQUIREMENTS. PROVIDE SAMPLING PORT PER AHJ WHEN REQURIED. 15 2" VENT BELOW GRADE. SLOPE AT 2% BACK TO SANITARY. 16 ROUTE THE CONDENSATE PIPING ON THE ROOF FROM THE ROOFTOP UNIT TO THE RESTROOM LAVATORY TAILPIECE. THE CONDENSATE SHALL BE CONNECTED TO THE ROOFTOP UNIT IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. VERIFY CONDENSATE REMOVAL REQUIREMENTS WITH LOCAL JURISDICTION PRIOR TO INSTALLATION. IF CONFLICTS OCCUR, NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY. LEGEND EXISTING NEW WORK ® NEW TO EXISTING CONNECTION ! 5 5Ci na&el ors. New Yuk•MIeM On®Fe LasAgC . — . H.—I 800mi-a 3 wMwsdtiudmLm m 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 = RECEIVED May 06 2024 CITY OF EDMONDS O DEVELOPMENT SERVICES DEPARTMENT O V_ 06 O 04 Q O/�� KT/ V ) v / v, w Z L�jQ 2zIt Q Q 0 50(l z0 <oz w w a W 01�00 a- a, w STORE #: 3232 PROJECT #: 03188-076 ISSUE DATE: 04/15/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRS Revision Schedule Rev Date By Description SHEET TITLE: PLUMBING WASTE AND (VENT PLAN SCALE: AS SHOWN SHEET NUMBER: P 102 0 N 0 3 W U) SHEET LEAD FLASHING MOP IN WITH ROOFING MA TERIAL TURN LEAD DOWN INTO N STACK (CANNOT RESTRICT z_ FLOW OF AIR) VENT CAP ROOFING INSULA TION ROOF CONSTRUCTION —SLEEVE- ROOF CONSTRUCTION MIN. 12" AS REQUIRED (PROVIDE FIRE RATED CAULKING WHEN REQUIRED BY L OCAL CODES) INCREASER (WHEN REQUIRED) VENT STACK OR STACK VENT HUB & SPIGOT TYPE PIPE SHOWN NO —HUB ALSO APPLICABLE VENT TERMINATION LEAD FLASHING 7 NOT TO SCALE UNDERCOUNTER BOILER FOR INSTANT HOT WAT- UNDERC INDIREC' FROM EE MACHINE INDIREC- LINE FRC RINSER FLOOR S UNDERC REFRIGE (TYP. 1 C ICE BIN / WITH INC AND INSI DRAIN LI FLOOR S BELOW UNDER COUNTER **FILTERED COLD WATER SUPPLY FOR ESPRESSO MACHINES (TYP. 1 OF 2) UNDERCOUNTER CABINET (TYP 1 OF 2) UNDERCOUNTER REFRIGERATOR (TYP. 1 OF 2) — ABOVE COUNTER CRAFT BAR CASEWOR=DETAIL THREE COMPARTMENT SINK DETAIL NOT TO SCALE 11'-7" *PROVIDE WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE CONNECTION **PROVIDE BACKFLOW PREVENTION DEVICE BEFORE PUMP AND WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE *** PLUMBING SUB -CONTRACTOR TO SUPPLY G 1/2 (BSP) FEMALE THREAD TO US 1/2 NPT MALE THREAD ADAPTER AT PITCHER RINSER. FOLLOW ADAPTER WITH BALL VALVE SHUT OFF PRIOR TO SUPPLY LINE. ESP 11-01 PLUMBING scale: 3/4" = V-0" *FILTERED COLD WATER SUPPLY FOR INSTANT HOT/COLD WATER BOILER (TYP. 1 OF 2) — �s INDIRECT DRAIN LINE FROM RINSER SINK TO FLOOR SINK 7"X3" (180MMX75MM) STUB -UP PENETRATION AREA. SEE BUILDING FLOOR PENETRATION PLAN FOR FINAL LOCATION. INSTALL SHUT-OFF VALVES BETWEEN STUB -UPS AND EQUIPMENT. INDIRECT DRAIN LINE FROM ESPRESSO MACHINE TO FLOOR SINK ICE BIN ABOVE WITH INDIRECT AND INSULATED DRAIN LINE TO FLOOR SINK BELOW FLOOR SINK (TYP. 1 OF 2) SEE PLUMBING PLAN FOR FINAL LOCATIONS AND TYPE * FILTERED COLD WATER SUPPLY FOR WATER TOWER DISPENSER (TYP. 1 OF 2) * FILTERED COLD WATER SUPPLY FOR INSTANT HOT/COLD WATER FONT (TYP. 1 OF 2) - NON -FILTERED COLD WATER SUPPLY FOR METERED SPOON RINSER (TYP. 1 OF 2) NON -FILTERED COLD WATER SUPPLY FOR PITCHER RINSER (TYP. 1 OF 2) ICE BIN (TYP. 1 OF 2) RINSER SINK (TYP. 1 OF 2) SLOPE FLOOR TO FLOOR DRAIN FLOOR DRAIN a a. as a a a oa TRAP WATER LEVEL &LOOR DRAIN DETAIL NOTT TO SCALE Plan Viev &�NOT LOOR SINK DETAIL TO SCALE FLOOR SINK SET ABOVE ECOGRP ECO-GRP INDIRECT WASTE LINE FLOORING FROM MT. REF PLAN CONIC. NFLL Q TRENCH SET SCREW FOR BELOW GRADE UTLITES NO-M OUTLET AR TWICE THE DIAMETER BREAKER. SIZE VARIESOF INLET, MIN ACCORDING TO WASTE LINE SIZE GRAVEL BACKFLL No -HUB coliNEcnoN OR SPIGOT OUTLET AS ALLOWED NO -HUB CONNECTION WASTE LINE TO RISER OR GREASE INTERCEPTOR 3" TAL PIECE AS REVD. 3 AIIRTBREEAKER DETAIL NOT DRAIN LINE FROM SINK TO WASTE LINE IN WALL OR TO FLOOR DRAIN SOFTENED HOT AND NON -FILTERED COLD WATER FOR SINK FAUCET BACK WALL INDIRECT DRAIN LINE FROM DISHWASHER TO NEAREST FLOOR DRAIN OR MOP SINK. WATER FOR DISHWASHER WITH SHUT-OFF UNDER SINK AT 18" (460MM) AFF. LINE LENGTH MUST ALLOW EASE OF MOVEMENT. VERIFY WATER REQUIREMENTS FOR TYPE OF DISHWASHER (HOT/COLD/SOFTENED). SEE WATER SUPPLY DRAWINGS FOR WATER LINE. IF ADVANSYS DISHWASHER, INCLUDE PRESSURE REDUCING VALVE. PRESSURE GAUGE (SET TO 20 PSIG +/- 5 PSI), LINE STRAINER AND SHOCK ARRESTOR. DRAIN LINE FROM DISHWARE DRYING RACKS TO SINK BOWL SEE PLUMBING PLAN FOR ----------------------------------------------------------- I FINAL FLOOR DRAIN LOCATION. FLOOR DRAIN OPTIONAL. I WIRE RACK I DISHWARE DRYING RACKS WITH DRAIN LINE TO SINK BOWL 3/4" PLYWOOD BACKER BOARD PRE -WASH STATION I BEHIND WALL FINISH. FASTEN TO STRUCTURE BEYOND. I I 31 /4" ALIGN I\ /I NOTE: \ / _ FOR COORDINATION ONLY. SEE \ I - FURNITURE, FIXTURES, AND EQUIPMENT PLAN FOR I V I EQUIPMENT LOCATIONS. n I PROVIDE BACKING BEHIND WALL / I FINISH AS REQUIRED FOR WALL / \ I MOUNTED EQUIPMENT. REFER \\ I TO ITEM SPECIFICATIONS FOR / \ I MORE INFORMATION. KEEP CLEAR FOR WALL MOUNTED CHEMICAL Elevation View DISPENSING SYSTEM, TO BE INSTALLED BY SYSTEM VENDOR. PROVIDE BACKING BEHIND WALL FINISH FOR EQUIPMENT MOUNTING. REFER TO POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION. SANITIZING (GENERIC) - PLUMBING scale: 3/4" = V-0" COMPARTMENT SINK DISHWASHER 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD I \R21002 - S tarbuckC In ter ur laan Avenue\GdQ-10Q0-b10CkjpQ GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 = RECEIVED May 06 2024 CITY OF EDMONDS O DEVELOPMENT SERVICES DEPARTMENT O r W O Q Q O 00 Q 0 U) Z 2 Q 7 0 0 CO C c 0 z0 <oz W W O ` W a- CF) W STORE #: 3232 PROJECT #: 03188-076 ISSUE DATE: 04/15/2024 DESIGN MANAGER: GRAPHITE PRODUCTION DESIGNER: GRAPHITE CHECKED BY: GRS Revision Schedule Rev Date By Description SHEET TITLE: PLUMBING DETAILS I SCALE: AS SHOWN SHEET NUMBER: P201 New Yuk• MIeM On®Fe Lna Argales SeaMe. Hontlul 800mi-a 3 wMwsdtiudmLm © 2022 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2021.10.22 ARCHITECT OF RECORD GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 RECEIVED May 06 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT # Revision Schedule Rev Date By Description PLUMBING DETAILS SHEET NUMBER: P202 © 2022 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 RECEIVED May 06 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT # Revision Schedule Rev Date By Description PLUMBING DETAILS SHEET NUMBER: P203 © 2022 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 RECEIVED May 06 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT # Revision Schedule Rev Date By Description PLUMBING DIAGRAM SCALE: AS SHOWN SHEET NUMBER: P301 © 2022 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: 2021.10.22 ARCHITECT OF RECORD GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206)224-3335 RECEIVED May 06 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT # Revision Schedule Rev Date By Description PLUMBING DIAGRAM SHEET NUMBER: P302