APPROVED FIR BLD BLD2024-0673+PLANS & Manufacturer_Specifications_and_Installation_Instructions+5.13.2024_2.02.41_PM+4253453FOR QUESTIONS, CALL THE
FLO AIRE NATIONAL
REGION 22
PHONE, (610) 239 - 8405
EMAIL, courtney.hardln@floalre.con
,UTTA FAIT TArFnRUATTn TT — .Tn P4R7GR.ri2n
111BYZiYZI11I:Y193
FAN
UNIT
TAG
QTY
FAN UNIT MODEL #
BLOWER
HOUSING
MIN
DESIGN
ESP
RPM
MOTOR
HP
BHP
PHASE
VOLT
FLA
MCA
MOCP
WEIGHT
SONES
NO
CFM
CFM
ENCL
<LBS)
1
1
SA20D
20MF-2-MOD
A2
1500
2500
0.600
1031
TEAO-ECM
2.000
0.6330
1
230
14.0
17.5A
30A
379
9.6
I N. a.1r )war IlvkY
FAN
UNIT
TAG
QTY
DESCRIPTION
NO
1
SIZE 2 UNTEMPERED COMMERCIAL DOWN DISCHARGE FOR DIRECT DRIVE AHUS
1
1
ECM WIRING PACKAGE - DD SUPPLY - MANUAL OR 0-10VDC REFERENCE SPEED CONTROL -MSC-
(TELCO)
1
2 YEAR PARTS WARRANTY
fIrTDD AVVr1I.f0T rWV
NO
FAN
WEIGHT
ITEM
SIZE
1
53 LBS
SUPPLY ADAPTER
FROM 35.500'SQ TO 31.000'SQ X 6.000'H.
r1Arr vnrrrrn nAIrA
SOUND DATA
OCTAVE BAND SOUND DATA
FAN
UNIT
TAG
MOTOR
LWA
SONES
DBA
DISTANCE
1 63 HZ
1 125 HZ
250 HZ
500 HZ
I KHZ
2 KHZ
4 KHZ
8 KHZ
NO
@ 5 FT
@ 5 FT
(FT)
1
SUPPLY
72.1
9.59240950714879
60.6
5
70.9
77,1
72.5
69.5
66
63.4
60
56
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
Approved
DFM c*sBurt
South County Fire
Date: 06/03/2024
06-03-2024
PLAN REVIEW
NOTES: APPROVED WITH
CONDITIONS:
1. HOOD CLEANING SERVICE
OVERDUE BY 480 DAYS.
2. HOOD SUPPRESSION SYSTEM
SERVICE OVERDUE BY 235 DAYS.
THESE SERVICES MUST BE
COMPLETED WITH DEFICIENT FREE
REPORTS SUBMITTED INTO "THE
COMPLIANCE ENGINE" PRIOR TO
FINAL INSPECTION REQUESTS.
DFM BURT
APPROVED
PLANS MUST BE
ON JOB SITE
Replacement of equipment
may require additional
alterations to upgrade
current hood system.
RECEIVED
May 20 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
City Of Edmonds
Building Department
Work RTU- MUA
Address 21110 76TH AVE W
Owner ROMEOS PIZZA
Approved Date 05/30/2024
Building Official Erg C'a-ter
---------------
Permit Number BLD2024-0673
JOB Supply Fan
O F�oNr
LOCATION ,
s DATE 4/17/2024 JOB # 6743520
rRk I DWG # 1 DRAWN BY courtneyh
REV. SCALE 3/8' = V-0'
FAN 81 SA20D - SUPPLY FAN
1. UNTEMPERED SUPPLY UNIT WITH 20' MIXED FLDW DIRECT DRIVE FAN IN SIZE 82 HOUSING.
2. INTAKE HOOD WITH EZ FILTERS.
3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT.
4. DOWN DISCHARGE CONSTRUCTION FOR SIZE 2 UNTEMPERED DIRECT DRIVE AHUS.
5. ECM WIRING PACKAGE AND MANUAL OR 0-I0VDC CONTROL FOR SUPPLY EC MOTORS. MSC CONTROLLER. "DO NOT ORDER UNDER
WARRANTY, SEE PART NUMBER 'CAS MSCmK
6. HINGED DOUBLE WALL INSULATED DOOR ASSEMBLY (BURNER/BLOWER SECTION).
7. 2 YEAR PARTS WARRANTY.
*NOTE- SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED
DOWNSTREAM OF UNIT DISCHARGE AS OUTLINED IN AMCA PUBLICATION 201. WHEN USING RECTANGULAR DUCTWORK, ELBOWS MUST
BE RADIUS THROAT, RADIUS BACK WITH TURNING VANES, FLEXIBLE DUCTWORK AND SQUARE THROAT/SQUARE BACK ELBOWS SHOULD
NOT BE USED. ANY TRANSITION AND/OR TURNS IN THE DUCTWORK WILL CAUSE SYSTEM EFFECT,
SYSTEM EFFECT WILL
DRASTICALLY INCREASE STATIC PRESSURE AND REDUCE AIRFLOW. DO NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY. FAILURE
TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT.
SUGGESTED STRAIGHT DUCT SIZE IS 20' x 20'.
19
6'
—r
oN� MINIMUM
CLEARANCE
MINIMUM
RECOMMENDED
COTOMBUSTIBLES.
SERVICE
CLEARANCE.
I
18 3/4 I I I I
I I I I I
L-J I
16' __-
93 3/4'
40 1/8'
AOFLOV.
SERVICE DISCONNECT
36 3/4' SWITCH.
O.OWER/M0TO2
ACCESS D=
24' SERVICE -11
CLEARANCE REQ
MINIMUM I
STRAIGHT
DUCT
PER AMCAN
�L--J
1 MIN. 20'
I
J I�
MINIMUM
RECOMMENDED
SERVICE
CLEARANCE.
I_
RECEIVED
May 20 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
FAN#1 — SUPPLY PERFORMANCE CURVES,
2500 CFM, 0.626 SP 2 1031 RPM AND 0.633 BHP AT 0 FEET AND 70 DEG F.
m PLEASE NOTE THAT THESE CURVES WERE ADJUSTED FOR JOB SPECIFIC TEMPERATURE AND ALTITUDE,
4.000
3.500
3.000
2.500
S P 2.000
1.500
1.000
0.500
01000
1500
1
Doo
�\ x
M
�
i
i�
i�
�
R,o
M
O'RpM
2000 2500 3000 3500 4000 4500 5000 5500 6000
CFM
RECEIVED
May 20 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT