Loading...
APPROVED FIR BLD BLD2024-0673+PLANS & Manufacturer_Specifications_and_Installation_Instructions+5.13.2024_2.02.41_PM+4253453FOR QUESTIONS, CALL THE FLO AIRE NATIONAL REGION 22 PHONE, (610) 239 - 8405 EMAIL, courtney.hardln@floalre.con ,UTTA FAIT TArFnRUATTn TT — .Tn P4R7GR.ri2n 111BYZiYZI11I:Y193 FAN UNIT TAG QTY FAN UNIT MODEL # BLOWER HOUSING MIN DESIGN ESP RPM MOTOR HP BHP PHASE VOLT FLA MCA MOCP WEIGHT SONES NO CFM CFM ENCL <LBS) 1 1 SA20D 20MF-2-MOD A2 1500 2500 0.600 1031 TEAO-ECM 2.000 0.6330 1 230 14.0 17.5A 30A 379 9.6 I N. a.1r )war IlvkY FAN UNIT TAG QTY DESCRIPTION NO 1 SIZE 2 UNTEMPERED COMMERCIAL DOWN DISCHARGE FOR DIRECT DRIVE AHUS 1 1 ECM WIRING PACKAGE - DD SUPPLY - MANUAL OR 0-10VDC REFERENCE SPEED CONTROL -MSC- (TELCO) 1 2 YEAR PARTS WARRANTY fIrTDD AVVr1I.f0T rWV NO FAN WEIGHT ITEM SIZE 1 53 LBS SUPPLY ADAPTER FROM 35.500'SQ TO 31.000'SQ X 6.000'H. r1Arr vnrrrrn nAIrA SOUND DATA OCTAVE BAND SOUND DATA FAN UNIT TAG MOTOR LWA SONES DBA DISTANCE 1 63 HZ 1 125 HZ 250 HZ 500 HZ I KHZ 2 KHZ 4 KHZ 8 KHZ NO @ 5 FT @ 5 FT (FT) 1 SUPPLY 72.1 9.59240950714879 60.6 5 70.9 77,1 72.5 69.5 66 63.4 60 56 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE Approved DFM c*sBurt South County Fire Date: 06/03/2024 06-03-2024 PLAN REVIEW NOTES: APPROVED WITH CONDITIONS: 1. HOOD CLEANING SERVICE OVERDUE BY 480 DAYS. 2. HOOD SUPPRESSION SYSTEM SERVICE OVERDUE BY 235 DAYS. THESE SERVICES MUST BE COMPLETED WITH DEFICIENT FREE REPORTS SUBMITTED INTO "THE COMPLIANCE ENGINE" PRIOR TO FINAL INSPECTION REQUESTS. DFM BURT APPROVED PLANS MUST BE ON JOB SITE Replacement of equipment may require additional alterations to upgrade current hood system. RECEIVED May 20 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT City Of Edmonds Building Department Work RTU- MUA Address 21110 76TH AVE W Owner ROMEOS PIZZA Approved Date 05/30/2024 Building Official Erg C'a-ter --------------- Permit Number BLD2024-0673 JOB Supply Fan O F�oNr LOCATION , s DATE 4/17/2024 JOB # 6743520 rRk I DWG # 1 DRAWN BY courtneyh REV. SCALE 3/8' = V-0' FAN 81 SA20D - SUPPLY FAN 1. UNTEMPERED SUPPLY UNIT WITH 20' MIXED FLDW DIRECT DRIVE FAN IN SIZE 82 HOUSING. 2. INTAKE HOOD WITH EZ FILTERS. 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT. 4. DOWN DISCHARGE CONSTRUCTION FOR SIZE 2 UNTEMPERED DIRECT DRIVE AHUS. 5. ECM WIRING PACKAGE AND MANUAL OR 0-I0VDC CONTROL FOR SUPPLY EC MOTORS. MSC CONTROLLER. "DO NOT ORDER UNDER WARRANTY, SEE PART NUMBER 'CAS MSCmK 6. HINGED DOUBLE WALL INSULATED DOOR ASSEMBLY (BURNER/BLOWER SECTION). 7. 2 YEAR PARTS WARRANTY. *NOTE- SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED DOWNSTREAM OF UNIT DISCHARGE AS OUTLINED IN AMCA PUBLICATION 201. WHEN USING RECTANGULAR DUCTWORK, ELBOWS MUST BE RADIUS THROAT, RADIUS BACK WITH TURNING VANES, FLEXIBLE DUCTWORK AND SQUARE THROAT/SQUARE BACK ELBOWS SHOULD NOT BE USED. ANY TRANSITION AND/OR TURNS IN THE DUCTWORK WILL CAUSE SYSTEM EFFECT, SYSTEM EFFECT WILL DRASTICALLY INCREASE STATIC PRESSURE AND REDUCE AIRFLOW. DO NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY. FAILURE TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT. SUGGESTED STRAIGHT DUCT SIZE IS 20' x 20'. 19 6' —r oN� MINIMUM CLEARANCE MINIMUM RECOMMENDED COTOMBUSTIBLES. SERVICE CLEARANCE. I 18 3/4 I I I I I I I I I L-J I 16' __- 93 3/4' 40 1/8' AOFLOV. SERVICE DISCONNECT 36 3/4' SWITCH. O.OWER/M0TO2 ACCESS D= 24' SERVICE -11 CLEARANCE REQ MINIMUM I STRAIGHT DUCT PER AMCAN �L--J 1 MIN. 20' I J I� MINIMUM RECOMMENDED SERVICE CLEARANCE. I_ RECEIVED May 20 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FAN#1 — SUPPLY PERFORMANCE CURVES, 2500 CFM, 0.626 SP 2 1031 RPM AND 0.633 BHP AT 0 FEET AND 70 DEG F. m PLEASE NOTE THAT THESE CURVES WERE ADJUSTED FOR JOB SPECIFIC TEMPERATURE AND ALTITUDE, 4.000 3.500 3.000 2.500 S P 2.000 1.500 1.000 0.500 01000 1500 1 Doo �\ x M � i i� i� � R,o M O'RpM 2000 2500 3000 3500 4000 4500 5000 5500 6000 CFM RECEIVED May 20 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT