Loading...
REVIEWED BLD2024-0786+Manufacturer_Specifications_and_Installation_Instructions+6.13.2024_9.31.09_AM+4319572Product Specifications OUTDOOR UNIT (a) (b) A4AC3048D1000A POWER CONNS. - V/PH/HZ (c) 208/230/1/60 MIN. CIR. AMPACITY 24 MAX. OVERCURRENT PROTECTION 40 COMPRESSOR SCROLL NO. USED - NO. STAGES 1 - 1 VOLTS/PH/HZ 208/230/1/60 R.L. AMPS (d) - L.R. AMPS 18.5 - 124 FACTORY INSTALLED YES/NO START COMPONENTS (e) NO INSULATION/SOUND BLANKET NO COMPRESSOR HEAT NO OUTDOOR FAN PROPELLER DIA. (IN.) - NO. USED 27.5 TYPE DRIVE - NO. SPEEDS DIRECT- 1 CFM @ 0.0IN. W.G. M 4410 NO. MOTORS - HP 1-1/5 MOTOR SPEED R.P.M. 825 VOLTS/PH/HZ 208/230/1/60 F.L. AMPS 0.93 OUTDOOR COIL - TYPE ALL ALUMINUM ROWS-F.P.I. 1-24 FACE AREA (SQ. FF.) 18.03 TUBE SIZE (IN.) 3/8 REFRIGERANT LBS. - R-410A (O.D. UNIT) (g) 5 LBS., 3 OZ FACTORY SUPPLIED YES LINE SIZE - IN. O.D. GAS (h) (i) 7/8 LINE SIZE - IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10OF DIMENSIONS H X W X D CRATED (IN.) 31.7 x 35 x 35 WEIGHT SHIPPING (LBS.) 189 NET (LBS.) 159 BLD2024-0786 RECEIVED Jun 14 2024 REVIEWED - 11VELOPMENrsa°CES BY DEPARTMENT CITY OF EDMONDS BUILDING DEPARTMENT (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. Optional authorized kits include KIT07689 for RunTru or BAYKSKT267. M Standard Air - Dry Coil - Outdoor (9) This value approximate. For more precise value see unit nameplate. (h) Reference the outdoor unit ship -with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312-xx or refrigerant piping application guide SS- APG006-xx for long line sets or specialty applications (xx denotes latest revision). (I) The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. Always verify proper system charge via subcooling (TXV/EEV) or superheat (fixed orifice) per the unit nameplate. AM-PRQ-A4AC3048D-1 A-E N