Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD2023-1084+Energy_Calculations+9.19.2023_2.12.32_PM+3792101
2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2023 NEEA, All rights reserved Project & Applicant Information Project Title SAW Construction - 2018 WSEC For Building Department Use: I Date: Sep 19, 2023 ............................................... REVIEWED BY CITY OF ED MON DS RES U B BLD2023-1084 Sep192023 BUILDING DEPARTMENTe CITY OF EDMONDS """"""""""""""""""""""".. DEVELOPMENT SERVICES Project Address 23107 1 00th Avenue West Suite 1 Edmonds, WA 98020 Applicant Name Braxten Tacbian Applicant Phone 206-643-1525 Applicant Email info@ 1 stresponsehvac.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Education, Preschool/Daycare Building Cond. Floor Area 9,389 General Project Types Alteration New Building or Addition Mechanical Scope P AlterationSingle Mechanical Scope Zone Systems &Equipment Project Cond. Floor Area 9,389 Floors Above Grade 1 Compliance Method Compliance Method 1 -General Mechanical Project Description Installation of 95% gas furnace and 4 Ton 16 SEER A/C unit Project Mechanical Scope Economizer Exception(s) DOAS Ventilation Higher Equipment Equipment Efficiency Compliance Mechanical Compliance �'P e Applied? Provided? Efficiency Option Applied? Y P PP Verification Scope and Method Single Zone Systems & Alteration Equipment Yes No NA COMPLIES Additional Efficiency Credits Included (AEC) Does building include occupancy classifications requiring No Does project include DOAS equipment? P I No DOAS? Based on project scope do TSPR requirements apply? No Do all systems comply with Appendix D standard reference design or qualify for an exception to No TSPR. Scope & Space Conditioning ALTERATION - SINGLE ZINKE SYSTEMS & EQUIPMENT Compliance Verification COMPLIES Single Zone Air Systems Category - Air conditioner, unitary, thru-wall, SDHV Air Systems Summary Information System/Equip ID Quantity of Items Supply Airflow Control Ventilation Standard Ventilation CFM (Total if Multiple Items) Ventilation Air Source Paired with DOAS Ventilation energy recovery Energy Recovery Efficiency (%) 4A7L6048AI000AI I Variable air volume I Unoccupied, no ventilation requirement Air Systems & Equipment - Cooling System/ Cooling System/Equip Type Specific Type Cooling Capacity AEC Efficiency Econo Exception Combined Efficiency Proposed Cooling CE Proposed Part PL Efficiency Compliance Equip ID per item (Btu/h) Multiplier Multiplier (FL & PL) Multiplier (AEC & Econo) Efficiency Units Load Efficiency Units Verification 4A7L6048AI000AI Air conditioner, air cooled JSplitsystemDXJ 47,000 1 1 1 0 1 1 1 16.0 1 SEER I I IEER I COMPLIES Air Systems & Equipment - Heating System /Equip ID Heating System/Equip T e g YP S ecitic Type P yP Heating Capacity g P y HC Units Proposed Heating Efficiency P g y HE Units Efficiency Compliance Verification 4A7L6048Al000AJ Furnace I Warm air, gas fired (AFUE) 100,000 Btu/h 95.0 AFUE COMPLIES Air Systems & Equipment Details System/Equip ID Area(s) Served Location In Project Documents - Plan/Detafl # 4A7L6048A1000Attdetail-2289}} Daycarettdetail-22551) ALL{{detail-2272}} Heating Section/Auxiliary Heating Type: Furnace Economizer Compliance Method: Economizer not required WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(1)A - Unitary Air Conditioners & Condensing Units WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(4) Warm Air Furnaces